J-1502000-14__Eastover _Preventative_Maintenance_Program_-_Index _Detail.xls

XLS spreadsheet 99 KB Posted

Attached to
MARFORRES SOUTHEAST FACILITIES MAINTENANCE
Solicitation number
W912HP13R0019
Issued by

About this file

Eastover Preventative Maintenance Index

View the file

Other files

File Type Posted
Award_Notice_MARFORRES_SE_Facilities_Maint.pdf PDF
J-0100000-01_MCRC_Locations.xls XLS spreadsheet
scannedDoc.pdf PDF
proposaldatasheet.pdf PDF
Schedule_B.xls XLS spreadsheet
Amendment_2.pdf PDF
Section_M_Revised.pdf PDF
Amendment_1.pdf PDF
Section_J_Part_1.pdf PDF
J-1502000-01__Huntsville _Drawings.pdf PDF
J-1502000-02__Montgomery _Drawings.pdf PDF
J-1502000-07__Memphis _Drawings.pdf PDF
J-1502000-05__Windy_Hill _Drawings.pdf PDF
J-1502000-03__Jacksonville _Drawings.pdf PDF
J-1502000-06__Eastover _Drawings.pdf PDF
J-1502000-08__Service_Call_Report.pdf PDF
J-1502000-04__Tampa _Drawings.pdf PDF
J-1502000-12__Tampa __Preventative_Maintenance_Program_-_Index _Detail.xls XLS spreadsheet
J-1502000-11__Jacksonville __Preventative_Maintenance_Program_Index _Detail.xls XLS spreadsheet
J-1502000-18__Equipment_Update_Report.xls XLS spreadsheet
Section_C.pdf PDF
Section_F__Deliveries_or_Performance.pdf PDF
Section_J__Documents _Exhibits _and_Other_Attachments.xls XLS spreadsheet
J-1502000-19__Equip_Inspection _Test_ _Certification_Program.xls XLS spreadsheet
J-1502000-10__Montgomery _Preventative_Maintenance_Program_-__Index _Detail.xls XLS spreadsheet
J-1502000-09__Huntsville _Preventative_Maintenance_Program_-_Index _Detail.xls XLS spreadsheet
Section_M.pdf PDF
J-1502000-17__Repair_Work_Report.xls XLS spreadsheet
SF_1449.pdf PDF
J-1502000-13__Windy_Hill __Preventative_Maintenance_Program_-_Index _Detail.xls XLS spreadsheet
J-1502000-16__Preventative_Maintenance_Program_-_Checklist.xls XLS spreadsheet
J-1502000-15__Memphis _Preventative_Maintenance_Program_-__Index _Detail.xls XLS spreadsheet
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Admin-Index

J-1502000-14
PREVENTATIVE MAINTENANCE PROGRAM INDEX
MCRC EASTOVER, SC
ADMINISTRATIVE BUILDING, HAZMAT LOCKER
(For Manufacturer, model and serial number of equipment see Detail tab)
EquipmentDesignationQuantityLocationContractor Developed PM Program Checklist Sheet (Note 2)Frequency of Inspection
1502000 Spec Item 3.2 - HVAC
Air Filter (HVAC)AF-1 through AF-99See Tab: Detail - Air FilterEvery Other Month
Air Handling UnitAHU-1 through AHU-44AHU-1 (Gear Locker 132), AHU-2 (Assembly Hall 134), AHU-3 (Gear Locker 132), AHU-4 (Supply Storage 150)Semiannual
BoilerB-11Mechanical 113Monthly, during heating season
Chiller - Air CooledCH-11Perimeter, adjacent to Mechanical 113XAs required by manufacturer, except coils shall be cleaned semiannually
Damper (Motorized)D-11Fire Pump 151Quarterly
Fan (duct)EF-1 through EF-4, SF-1, SF-26EF-1, SF-2 (Mechanical 113), EF-2 (Med Toilet 120), SF-1, EF-3 (Gear Locker 132), EF-4 (Fire Pump 151)Annual
Fan Coil UnitFCU-1 through FCU-33FCU-1 (Comm Rm 122), FCU-2 (Comm Tech 135), FCU-3 (Armory 131)Annual (spring)
Heater-Unit, Forced Air, ElectEUH-11Fire Pump 151Annual (fall)
System Water-ChilledCW-11Mechanical 113XAnnual (Note 3)
System Water-Heating Hot WaterHW-11Mechanical 113XAnnual (Note 3)
Terminal-VAVV-1 through V-1616See Tab: Admin-VAVAnnual
1502000 Spec Item 3.2 - Electrical Systems
Lighting (exterior)LightingLights attached to all buildings and pole lightingQuarterly
Lighting (interior)LightingAdministrativeQuarterly
PanelboardPB-A, PB-B, PB-C, PB-M, PB-MDP, PB-HA, PB-LA7PB-A (Hall 103), PB-B (Hall 102), PB-C (Assembly Hall 134), PB-M, PB-MDP (Mechanical 113), PB-HA, PB-LA (Supply Storage 150)Annual
1502000 Spec Item 3.2 - Fire Protection
Fire Detection and Alarm SystemFA-11Administrative BuildingAnnual
Fire Extinguisher (portable)-Monthly InspectionFE-1 through FE-1010FE-1, FE-2 (Hall 102), FE-3 (Hall 103), FE-4 (Mechanical 113), FE-5 (Gear Locker 132), FE-6 (Assembly Hall 134), FE-7, FE-8, FE-9 (Supply Storage 150), FE-10 (Fire Pump 151)Monthly
Fire Extinguisher (portable)-Annual MaintenanceFE-1 through FE-1010FE-1, FE-2 (Hall 102), FE-3 (Hall 103), FE-4 (Mechanical 113), FE-5 (Gear Locker 132), FE-6 (Assembly Hall 134), FE-7, FE-8, FE-9 (Supply Storage 150), FE-10 (Fire Pump 151)Annual
Fire HydrantFH-11PerimeterAnnual
Fire PumpFP-11Fire Pump 151Monthly
Pump (Jockey pump)P-11Fire Pump 151Monthly
Fire Sprinkler, WetFSW-11Administrative BuildingAnnual
1502000 Spec Item 3.2 - Miscellaneous Equipment
Door-Overhead (motorized)DR-11Supply Storge 150Semiannual
Drinking FountainDF-1 through DF-44DF-1, DF-2 (Hall 102), DF-3, DF-4 (Assembly Hall 134)Annual
Gutters/Down Spouts CleaningG-11Vehicle Wah FacilityAnnual
Plumbing Fixtures (by room)PF-1 through PF-66PF-1 (Med Toilet 120), PF-2 (Womens Toilet 125), PF-3 (Janitorial 126), PF-4 (Mens Toilet 128), PF-5 (Mens Locker Room 129), PF-6 (Shower 129A)Semiannual
Pump (chilled water)CHWP-1, CHWP-22Mechanical 113Semiannual
Pump (hot water)HWP-1, HWP-22Mechanical 113Annual
Pump-SumpPS-11Supply Storge 150Semiannual
Shutter-Roll-up (manual)S-11Comm Tech 135Semiannual
Shutter-Roll-up (motorized)S-21Supply Storge 150Semiannual
Water Heater-ElectricWHE-11Mechanical 113Annual
Water Heater-OilWHG-11Mechanical 113Semiannual
NOTES
Note 1 - HVAC equipment shall be inspected in the spring or fall unless otherwise noted
Note 2 - If blank, Government will provide PM Program checklist sheet
Note 3 -Shall be treated/tested after repairs/leaks resulting in refilling of the system
Note 4 - For quantity/size of air filters (HVAC) see Tab: Air Filters (HVAC)
Note 5 - For quantity of plumbing fixtures see Tab: Plumbing Fixtures

Page &P of &N

Admin-Detail

J-1502000-14
PREVENTATIVE MAINTENANCE PROGRAM EQUIPMENT DETAIL
MCRC EASTOVER, SC
ADMINISTRATIVE BUILDING
EquipmentDesignationManufacturerModelSerial NumberRemarks
1502000 Spec Item 3.2 - HVAC
Air Handling UnitAHU-1McQuayCAH 017 GDACChw coil, supply and return fan, Condensate pump, VFD
Air Handling UnitAHU-2McQuayLAH 010 AChw and reheat coils
Air Handling UnitAHU-3McQuayLAH 005 ADHTLN U 07 07 00003Chw and reheat coils, Condensate pump
Air Handling UnitAHU-4McQuayLAH 010 ADVTLN U 07 07 00004Chw and reheat coils
BoilerB-1Weil-McLainModel 88, Series 1Oil
Chiller - Air CooledCH-1McQuayAGZ085BSS27-ER11STNU070600276
Fan Coil UnitFCU-1Enviro-TecHLP-Horizontal Concealed Plenum ReturnChw and reheat coils
Fan Coil UnitFCU-2, FCU-3Enviro-TecHLE-Horizontal Ceiling Exposed CabinetChw and reheat coils
Terminal-VAVV-1 through V-16Enviro-TecSDR-WCSingle duct, Hot water coil
1502000 Spec Item 3.2 - Fire Protection
Fire PumpFP-1Patterson Pump Company8x8 MJFP-C0667451000 GPM, 40 psig, 30 HP
Pump (Jockey pump)P-1GrundfosCR1-7 A-FGJ-A-E-HQQE.75 HP
1502000 Spec Item 3.2 - Miscellaneous Equipment
Pump (chilled water)CHWP-1, CHWP-2TacoKV3009AE2KC8721M168 GPM, 70 hd ft, 7.5 HP
Pump (hot water)HWP-1, HWP-2Taco191940 GPM, 60 hd ft, 2 HP
Water Heater-ElectricWHE-1State SelectP6301OMSX30 gal
Water Heater-OilWHG-1AO SmithCOF 199-940K04M001630Oil, 86 gal

Page &P of &N

Admin-VAV

J-1502000-14
PREVENTATIVE MAINTENANCE PROGRAM DETAIL
VAV LOCATION
MCRC EASTOVER, SC
VAV DesignationLocationSpace Served
V-1Classroom 121Classroom 121
V-2Classroom 121Classroom 121
V-3Classroom 115Classroom 115
V-4Classroom 115Classroom 115
V-5Classroom 115Classroom 115
V-6Med Office 116Med Office 116, Dentist 117, Med Exam 119, Med Toilet 120
V-7Supply Office 114Supply Office 114
V-8Hall 102Hall 102
V-9Conference Room 104Conference Room 104
V-10Lounge 123Lounge 123
V-11Lounge 123Womens Toilet 125, Janitorial 126, Mens Toilet 128, Mens Locker Room 129
V-12Office 106Office 105, Office 106
V-13Office 107Office 107
V-14Hall 103Hall 103, Office 108
V-15Office 136Office 136 through Office 141
V-16Hall 103Recruiting 110, Training and Storage 111

Page &P of &N

VMF-Index

J-1502000-14
PREVENTATIVE MAINTENANCE PROGRAM INDEX
MCRC EASTOVER, SC
VMF, HAZMAT LOCKER, GROUNDS
(For Manufacturer, model and serial number of equipment see Detail tab)
EquipmentDesignationQuantityLocationContractor Developed PM Program Checklist Sheet (Note 3)Frequency of Inspection
1502000 Spec Item 3.2 - HVAC
Air Filter (HVAC)AF-1, AF-22See Tab: Detail - Air FilterEvery Other Month
Damper (motorized)D-1, D-2, D-33DM-1 (Tool Rm 101), DM-2 (Oil Drum Storage 103), DM-3 (Mechanical Rm 154)Quarterly
Fan (duct)EF-3 through EF-5, EF-6 (vehicle exhaust)4EF-3 (Tool Rm 102), EF-4 (Oil Drum Storage 103), EF-5 (Restroom 153), EF-6 (Bay 150)Semiannual
Fan (roof)EF-1, EF-22RoofQuarterly
Fan (wall)EF-7 through EF-104EF-7 (Mechanical Rm 154), EF-8 (Battery Rm 155), EF-9 (Electrical 156), EF-10 (HazMat Locker 1)Semiannual
Fan Coil UnitHP-1 (indoor unit)1Coridor 203Annual (spring)
Heat Pump - SplitHP-1 (outdoor unit)1Perimeter, adj to Oil Drom Storage 103Semiannual
Heat Pump - PackageHP-2 (thru wall)1Office 151Semiannual
Heater - Unit, Forced Air, ElectEUH-1 through EUH-44EUH-1 (Tool Rm 101), EUH-2 (Parts Rm 102), EUH-3 (Oil Drum Storage 103), EUH-4 (Battery Rm 155)Annual (fall)
Heater - Unit, Forced Air, GasGUH-1 through GUH-44GUH-1 (Bay 150), GUH-2, GUH-3 (Bay 100), GUH-4 (Bay 150)Annual (fall)
1502000 Spec Item 3.2 - Electrical Systems
Lighting (exterior)LightingVMF (lights attached to building exterior), Pole lightingQuarterly
Lighting (interior)LightingVMF, HazMat Locker 1Monthly
PanelboardPB-PA, PB-MDB, PB-PB, PB-HazMat1, PB-LA (Adj to Drum Storage Facility)5PB-PA, PB-MDB (Elect/Telecom 157), PB-PB (Electrical 156), PB-HazMat (HazMat Locker 1), PB-LA (Adj to Drum Storage Facility)Annual
1502000 Spec Item 3.2 - Fire Protection
Fire Detection and Alarm SystemFA-11VMFAnnual
Fire Extinguisher (portable) - Monthly InspectionFE-1 through FE-66FE-1 (Oil Drum Storage 103), FE-2 (Bay 150), FE-3, FE-4 (Corridor 203), FE-5 (Mezzaine 250), FE-6 (Vehicle Fuel Dispensing Station)Monthly
Fire Extinguisher (portable) - Annual MaintenanceFE-1 through FE-66FE-1 (Oil Drum Storage 103), FE-2 (Bay 150), FE-3, FE-4 (Corridor 203), FE-5 (Mezzaine 250), FE-6 (Vehicle Fuel Dispensing Station)Annual
Fire Sprinkler, Dry ChemicalFSD-11FSD-1 (HazMat Locker 1)Monthly
Fire Sprinkler - Wet PipeFSW-11VMFAnnual
1502000 Spec Item 3.2 - WHE
Crane - Overhead BridgeCOB-11Bay 100XAs required by the manufacturer
Hydraulic Lift - AutoHLA-11Bay 150XAs required by the manufacturer
1502000 Spec Item 3.2.5 - Miscellaneous Equipment
Air CompressorAC-1, AC-22Mezzaine 250Semiannual
Air Dryer - RefrigerantADR-11Mezzaine 250Semiannual
Door, Overhead (motorized)DR-1 through DR-56DR-1 (Bay 100), DR-2 through DR-6 (Bay 150)Semiannual
Drinking FountainDF-11Bay 150Annual
Emergency Eyewash & ShowerEES-1, EES-22EES-1 (Bay 100), EES-2 (Bay 150)Monthly
Plumbing Fixtures (by room)PF-1, PF-22PF-1 (Bay 150), PF-2 (Restroom 153)Semiannual
PumpDHWP-11Mezzaine 250Annual
Slide Gate Operator & Entry SystemSGO-11EntranceSemiannual
Water Heater-ElectricWH-11Mezzaine 250Annual
NOTES
Note 1 - Equipment listed without a building name is located in the VMF
Note 2 - HVAC equipment shall be inspected in the spring or fall unless otherwise noted
Note 3 - If blank, Government will provide PM Program checklist sheet
Note 4 - For quantity/size of air filters (HVAC) see Tab: Air Filters (HVAC)
Note 5 - For quantity of plumbing fixtures see Tab: Plumbing Fixtures

Page &P of &N

VMF-Detail

J-1502000-14
PREVENTATIVE MAINTENANCE PROGRAM EQUIPMENT DETAIL
MCRC EASTOVER, SC
VMF, HAZMAT LOCKER, GROUNDS
EquipmentDesignationManufacturerModelSerial NumberRemarks
1502000 Spec Item 3.2 - HVAC
Fan (roof)EF-1GreenheckLB-24-711526293 0810
Fan (roof)EF-2GreenheckLB-24-711526292 0810
Fan Coil UnitHP-1 (indoor unit)CarrierFX4CNF0244508A69574
Heat Pump - SplitHP-1 (outdoor unit)Carrier25HBB324A3004608E11669
Heat Pump - PackageHP-2Carier52CQF207351AA2308X85595
Heater - Unit, Forced Air, ElectHUE-1TPI CorporationF1F5105NTaskmaster
Heater - Unit, Forced Air, ElectHUE-2TPI CorporationF1F5103NTaskmaster
Heater - Unit, Forced Air, ElectHUE-3TPI CorporationTaskmaster
Heater - Unit, Forced Air, ElectHUE-1TPI CorporationHF2B5103NTaskmaster
Heater - Unit, Forced Air, GasGUH-1 through GUH-4ReznorF75-E-3
1502000 Spec Item 3.2 - WHE
Crane - Overhead BridgeCOB-1Eastern Crane & Hoist Inc (Hoist: R&M Materials Handling Inc)Hoist - SX50410080P56FDL04Hoist - HHW1080315,000 pounds
Hydraulic Lift - AutoHLA-1Rotary LiftSP09-200AFL00A00999000 pounds
1502000 Spec Item 3.2 - Miscellaneous Equipment
Air CompressorAC-1Compair KellogB335BL9904313 HP
Air CompressorAC-2Compair Kellog5 HP
Air Dryer - RefrigerantADR-1Ingersol-RandModel-ESSICC Description-DSS50-H IR3402860003
Slide Gate Operator & Entry SystemSGO-1OscoGSLG-A-1110401531647E
Water Heater-ElectricWH-1AO SmithECT 40 2000816A03122040 gallon

Page &P of &N

Detail - AF

J-1502000-14
PREVENTATIVE MAINTENANCE PROGRAM EQUIPMENT DETAIL
AIR FILTER (HVAC)
MCRC EASTOVER, SC
(FILTER SIZE/QUANTITY SHALL BE FIELD VERIFIED BEFORE PURCHASING REPLACEMENT FILTERS)
DESIGNATIONEQUIPMENTFILTER 1FILTER 2FILTER 3FILTER 4
SIZEQUANTITYSIZEQUANTITYSIZEQUANTITYSIZEQUANTITY
ADMINISTRATIVE
AF-1AHU-124x24x29
AF-2AHU-216x20x26
AF-3AHU-316x20x24
AF-4AHU-420x25x23
AF-5FCU-18x30x12
AF-6FCU-28x30x12
AF-7FCU-38x30x12
AF-8SF-1
AF-9SF-2
VMF
AF-1HP-1 (indoor unit)20x20x12
AF-2HP-2 (indoor unit)20x20x12

Page &P of &N

Detail - PF

J-1502000-14
PREVENTATIVE MAINTENANCE PROGRAM EQUIPMENT DETAIL
PLUMBING FIXTURE
MCRC EASTOVER, SC
FIXTUREQUANTITY
Sink13
Shower Head7
Toilet6
Urinal3

Page &P of &N