Admin, VMF, HMAT-Index
| J-1502000-09 | |||||
| PREVENTATIVE MAINTENANCE PROGRAM INDEX | |||||
| MCRC HUNTSVILLE, AL | |||||
| ADMINISTRATIVE, VMF, HAZMAT LOCKERS, GROUNDS | |||||
| (For Manufacturer, model and serial number of equipment see Equipment Detail tab) | |||||
| Equipment | Designation | Quantity | Location | Contractor Developed PM Program Checklist Sheet (Note 3) | Frequency of Inspection |
| 1502000 Spec Item 3.2 - HVAC | |||||
| Air Conditioner - Package, Gas Heat | RTU-1 | 1 | Adj to Administrative Building | Semiannual | |
| Air Conditioner-Window | ACW-1 | 1 | VMF, Office 205 | Annual | |
| Air Filter (HVAC) | AF-1, AF-2 | 2 | See Tab: Detail - Air Filter | Every Other Month (during heating season) | |
| Air Filter (HVAC) | AF-3, AF-4, AF-5, AF-6 through AF-12 | 10 | See Tab: Detail - Air Filter | Every Other Month | |
| Air Handling Unit - Gas Heat Only | AHU-1, AHU-2 | 2 | Drill Hall 137 | Annual (fall) | |
| Fan (duct) | EF-1 (vehicle exhaust) | 1 | VMF, Maintenance 201 | Semiannual | |
| Fan (duct) | EF-2, EF-3 | 2 | EF-2 (Enlisted Womens Head 131, ceiling), EF-3 (Janitorial 133, ceiling) | Annual | |
| Fan (roof) | EF-1, EF-4, EF-5, EF-6 | 6 | EF-1 (serves Enlisted Mens Head 132), EF-4 (serves Womens Head 106), EF-5 (serves Mens Head 108), EF-6 (serves Shower 124 and Mens Head 125) | Quarterly | |
| Fan (wall) | EF-7, EF-8, EF-9 | 3 | EF-7 (VMF, Storage 204), EF-8 (HazMat Locker 1), EF-9 (HazMat Locker B) | Semiannual | |
| Fan Coil Unit | FCU-1through FCU-7 (AHU-6 on J-1502000-01) | 7 | FCU-1, FCU-2 (Administration 143), FCU-3 (Training 103), FCU-4 (I&I Office 142), FCU-5 (1st Sgt Office 141),FCU-6 (Battery Office 112), FCU-7 (Medical 113) | Annual (spring) | |
| Heat Pump - Split | HP-1 through HP-7 (HP-6 on J-1502000-01) | 7 | HPS-1 through HPS-3 (Perimeter, adj to Administration 143), HPS-4 (Perimeter, adj to I&I Office 142), HPS-5 (Perimeter, adj to 1st Sgt Office 141), HPS-6, HPS-7 (Perimeter, adj to Enlisted Mens Head 132) | Semiannual | |
| Heater-Unit, Forced, Gas | UH-1, UH-2, UH-3, UH-4, UH-5 | 5 | VMF, Maintenance 201 | Annual (fall) | |
| Rooftop Unit - Gas Heat | RTU-2 | 1 | Roof | Semiannual | |
| 1502000 Spec Item 3.2 - Electrical Systems | |||||
| Lighting (exterior) | Lighting | Light fixtures attached to Administrative and VMF and pole lighting | Quarterly | ||
| Lighting (interior) | Lighting | Administrative Building, VMF, HazMat Locker A, HazMat Locker B | Quarterly | ||
| Panelboard | PB-MDP, PB-P1, PB-P2, PB-P3, PB-NMCI, PB-L2, PB-PE, PB-PF, PB-WP, PB-HazMatA, PB-HazMatB, PB-6 | 12 | PB-MDP (Mech Rm 134), PB-P1 (Mech Rm 134), PB-P2 (Vestibule 105), PB-P3 (Weight Rm 127), PB-NMCI (Duty Rm 135), PB-L2 (Drill Hall 137), PB-PE (VMF, Rm 201), PB-PF (VMF, Rm 201), PB-WP (De-mucking station), PB-HazMatA (Hazmat Locker A), PB-HazMatB (HazMat Locker B), PB-6 (Parking Lot) | Annual | |
| 1502000 Spec Item 3.2.3 - Fire Protection | |||||
| FP - Detection and Alarm System | FA-1. FA-2 | 2 | FA-1 (Administrative Building), FA-2 (VMF) (Note 6) | Annual | |
| Fire Extinguisher (portable)-Monthly Inspection | FE-1 through EF-9 | 9 | FE-1 (Vestibule 105), FE-2 (Vestibule 115), FE-3 (Corridor 122), FE-4 (Corridor 136), FE-5 (Drill Hall 137), FE-6 (Drill Hall 37), FE-7 through FE-9 (VMF, Rm 201) | Monthly | |
| Fire Extinguisher (portable)-Annual Maintenance | FE-1 through EF-9 | 9 | FE-1 (Vestibule 105), FE-2 (Vestibule 115), FE-3 (Corridor 122), FE-4 (Corridor 136), FE-5 (Drill Hall 137), FE-6 (Drill Hall 37), FE-7 through FE-9 (VMF, Rm 201) | Annual | |
| Fire Sprinkler - Chemical (dry/wet) | FSC-1, FSC-2 | 2 | FSC-1 (HazMat Locker A), FSC-2 (HazMat Locker B) | Monthly | |
| 1502000 Spec Item 3.2 - WHE | |||||
| Crane-Gantry (mobile) | CG-1 | 1 | VMF, Maintenance 201 | X | As required by the manufacturer |
| Crane-Jib (manual hoist) | CJ-1 | 1 | VMF, Maintenance 201 | X | As required by the manufacturer |
| Hydraulic Lift-Auto | HLA-1 | 1 | VMF, Maintenance 201 | X | As required by the manufacturer |
| Hydraulic Lift - Loading Dock | HLD-1 | 1 | Loading Ramp | Semiannual | |
| 1502000 Spec Item 3.2 - Miscellaneous Equipment | |||||
| Aftercooler - Compressed Air | ACA-1 | 1 | VMF, Maintenance 201 | Semiannual | |
| Air Compressor | AC-1, AC-2 | 2 | VMF, Maintenance 201 | Semiannual | |
| Air Dryer - Desiccant | ADD-1 | 1 | VMF, Maintenance 201 | Semiannual | |
| Air Filter - Compressed Air | AFC-1 | 1 | VMF, Maintenance 201 | Semiannual | |
| Door-Overhead (motorized) | DR-1 through DR-5 | 5 | DR-1 (Drill Hall 137), DR-2 through DR-5 (VMF, Maintenance 201) | Semiannual | |
| Drinking Fountain | DF-1, DF-2 | 2 | DF-1 (Drill Hall 137), DF-2 (VMF, Maintenance 201) | Semiannual | |
| Emergency Eyewash | EE-1 | 1 | VMF, Maintenance 201 | Monthly | |
| Filter - Cartridge (potw system) | F-1 | 1 | Mechanical Room 134 | Monthly | |
| Plumbing Fixtures (by room) | PF-1 through PF-8 | 8 | PF-1 (Womens Head 106), PF-2 (Mens Head 108), PF-3 (Shower 124), PF-4 (Mens Head 125), PF-5 (Enlisted Womens Head 131), PF-6 (Enlisted Mens Head 132), PF-7 (Janitor 133), PF-8 (VMF, Head 202) | Semiannual | |
| Pump (potw) | P-1 | 1 | Mech Stor 121 | Annual | |
| Slide Gate Operator & Entry System | SGO-1 | 1 | Front entrance | Semiannual | |
| Water Heater-Electric | WHE-1 | 1 | VMF, Rm 208 (Mezzaine) | Annual | |
| Water Heater-Gas | WHG-1, WHG-2 | 2 | WHG-1 (Mech Stor 121), WHG-2 (Mech Rm 134) | Semiannual | |
| NOTES | |||||
| Note 1 - Equipment listed without a building name is located in the Administrative building | |||||
| Note 2 - HVAC equipment shall be inspected in the spring or fall unless otherwise noted | |||||
| Note 3 - If blank, Government will provide PM Program checklist sheet | |||||
| Note 4 - For quantity/size of air filters (HVAC) see Tab: Air Filters (HVAC) | |||||
| Note 5 - For quantity of plumbing fixtures see Tab: Plumbing Fixtures | |||||
| Note 6 - VMF fire alarm system is tied into the Administrative building fire alarm control panel |
Page &P of &N
Admin, VMF, HMAT-Det
| J-1502000-09 | |||||
| PREVENTATIVE MAINTENANCE PROGRAM EQUIPMENT DETAIL | |||||
| MCRC HUNTSVILLE, AL | |||||
| ADMINISTRATIVE, VMF, HAZMAT LOCKERS, GROUNDS | |||||
| Equipment | Designation | Manufacturer | Model | Serial Number | Remarks |
| 1502000 Spec Item 3.2 - HVAC | |||||
| Air Conditioner - Package, Gas Heat | RTU-1 | Rheem | RKKB-A300CM40E | 2D6788ADAAF230412009 | 9000 cfm, 7.5 HP, Scroll compressors, Fuel-NG |
| Air Conditioner-Window | ACW-1 | Whirlpool | |||
| Air Handling Unit - Gas Heat Only | AHU-1, AHU-2 | Modine | |||
| Fan (roof) | EF-1 | Breidert Air Products | RED08 | 33415 | 400 cfm, Centrifugal, Rooftop, Direct drive |
| Fan (roof) | EF-4 | Breidert Air Products | RED08 | 33416 | 420 cfm, Centrifugal, Rooftop, Direct drive |
| Fan (roof) | EF-5 | Breidert Air Products | RED08 | 33417 | 420 cfm, Centrifugal, Rooftop, Direct drive |
| Fan (roof) | EF-6 | Breidert Air Products | RED08 | 33418 | 600 cfm, Centrifugal, Rooftop, Direct drive |
| Fan Coil Unit | FCU-1 | Daiken Industries | FTXS15DVJU | E001679 | |
| Fan Coil Unit | FCU-2 | Daiken Industries | FTXS15DVJU | E001678 | |
| Fan Coil Unit | FCU-3 | Daiken Industries | FTXS15DVJU | E001676 | |
| Fan Coil Unit | FCU-4 | Daiken Industries | FTXS15DVJU | E001681 | |
| Fan Coil Unit | FCU-5 | Daiken Industries | FTXS15DVJU | E001685 | |
| Fan Coil Unit | FCU-6 | Daiken Industries | FTXS15DVJU | E001677 | |
| Fan Coil Unit | FCU-7 | Daiken Industries | FTXS15DVJU | E001637 | |
| Heat Pump - Split | HP-1 | Daiken Industries | RX15FVJU | E000724 | |
| Heat Pump - Split | HP-2 | Daiken Industries | RX15FVJU | E000670 | |
| Heat Pump - Split | HP-3 | Daiken Industries | RX15FVJU | E000679 | |
| Heat Pump - Split | HP-4 | Daiken Industries | RX15FVJU | E000666 | |
| Heat Pump - Split | HP-5 | Daiken Industries | RX15FVJU | E000668 | |
| Heat Pump - Split | HP-6 | Daiken Industries | RX15FVJU | E000760 | |
| Heat Pump - Split | HP-7 | Daiken Industries | RX15FVJU | E000725 | |
| Rooftop Unit - Gas Heat | RTU-2 | Rheem | RKKB-A180CL35E | 2D6606ADAAF100406444 | 5400 cfm, 3 HP, Scroll compressors, Fuel-NG |
| 1502000 Spec Item 3.2 - WHE | |||||
| Crane-Gantry (mobile) | CGM-1 | Abell-Howe | 5-15-15 | 5 Ton capacity, Chain hoist | |
| Crane - Jib | CJ-1 | Spanco | 102-1206-0814 | 9809217 | 1/2 Ton capacity, Chain hoist |
| Hydraulic Lift - Automotive | HLA-1 | Electric-Hydraulic, 10,000 # capacity | |||
| 1502000 Spec Item 3.2 - Miscellaneous Equipment | |||||
| Aftercooler - Compressed Air | ACA-1 | Thermal Transfer Products, Inc | AA-35-1 | X2450 | |
| Air Compressor | AC-1 | Ingersoll-Rand | 2475 | 4016219 | Electric, Belt drive |
| Air Compressor | AC-2 | Speedaire | 4B236B | L4/29/99-00033 | Electric, Belt drive |
| Air Dryer - Desiccant | ADD-1 | Ingersoll-Rand | TZM024 | 53282A | |
| Air Filter - Compressed Air | AFC-1 | Ingersoll-Rand | |||
| Filter - Cartridge (potw system) | F-1 | Harmsco | Filter: HUR 1x 170FL Cartridge: HC-170-5 | ||
| Pump (potw) | P-1 | Bell & Gossett | Centrifugal | ||
| Slide Gate Operator & Entry System | SGO-1 | Liftmaster | Model SL580 | ||
| Water Heater - Gas | WHG-1 | A.O. Smith | HW300872 | 872B892924 | |
| Water Heater - Gas | WHG-2 | Bradford White Corp | D80T1803N | AJ5170650 | 80 Gallon tank |
Page &P of &N
HIMARS-Index
| J-1502000-09 | |||||
| PREVENTATIVE MAINTENANCE PROGRAM INDEX | |||||
| MCRC HUNTSVILLE, AL | |||||
| HIMARS MAINTENANCE FACILITY (BUILDING 3506B) | |||||
| (For Manufacturer, model and serial number of equipment see Detail tab) | |||||
| Equipment | Designation | Quantity | Location | Contractor Developed PM Program Checklist Sheet (Note 2) | Frequency of Inspection |
| 1502000 Spec Item 3.2 - HVAC | |||||
| Air Filter (HVAC) | AF-1 through AF-5 | 5 | See Tab: Detail - Air Filter | Every Other Month | |
| Fan (duct) | EF-1 | 1 | Head 102 | Annual | |
| Fan (wall) | EF-2, EF-3 | 2 | Maintenance Bay 100 | Semiannual | |
| Fan Coil Unit | AHU-1 through AHU-5 | 5 | AHU-1 (Office 101), AHU-2 (Head 102), AHU-3 (Shop & Parts Storage 103), AHU-4, AHU-5 (Mezzanine 200) | Annual (spring) | |
| Heat Pump - Split | HP-1 through HP-4 | 4 | Perimeter | Semiannual | |
| Heater - Unit, Forced Air, Gas | UH-1 | 6 | Maintenance Bay 100 | Annual (fall) | |
| 1502000 Spec Item 3.2 - Electrical Systems | |||||
| Lighting (exterior) | Lighting | On exterior of building | Quarterly | ||
| Lighting (interior) | Lighting | HIMARS Maintenance Facility | Quarterly | ||
| Panelboards | PB-4, PB-5 | 2 | Maintenance Bay 100 | Annual | |
| 1502000 Spec Item 3.2 - Fire Protection | |||||
| Fire Detection and Alarm System | FA-1 | 1 | HIMARS Maintenance Facility | Annual | |
| Fire Extinguisher (portable) - Monthly Inspection | FE-1 through FE-3 | 3 | FE-1, FE-2 (Maintenance Bay 100), FE-3 (Office 101) | Monthly | |
| Fire Extinguisher (portable) - Annual Maintenance | FE-1 through FE-3 | 3 | FE-1, FE-2 (Maintenance Bay 100), FE-3 (Office 101) | Annual | |
| 1502000 Spec Item 3.2 - WHE | |||||
| Crane - Overhead (monorail), Electric | COE-1 | 1 | Maintenance Bay 100 | X | As required by the manufacturer |
| 1502000 Spec Item 3.2 - Miscellaneous Equipment | |||||
| Air Compressor | AC-1 | 1 | Maintenance Bay 100 | Semiannual | |
| Air Dryer - Refrigerant | ADR-1 | 1 | Maintenance Bay 100 | Semiannual | |
| Door-Overhead (electric) | DR-1, DR-2 | 2 | Maintenance Bay 100 | Semiannual | |
| Emergency Eyewash & Shower | EES-1 | 1 | Maintenance Bay 100 | Monthly | |
| Plumbing Fixtures (by room) | PF-1 | 1 | Head 102 | Semiannual | |
| Pump - Sanitary Lift | PSL-1, PSL-2 | 2 | Perimeter, sewage lift station | Annual | |
| Water Heater-Electric | WHE-1 | 1 | Head 102 | Annual | |
| NOTES | |||||
| Note 1 - HVAC equipment shall be inspected in the spring or fall unless otherwise noted | |||||
| Note 2 - If blank, Government will provide PM Program checklist sheet | |||||
| Note 3 - For quantity/size of air filters (HVAC) see Tab: Air Filters (HVAC) | |||||
| Note 4 - For quantity of plumbing fixtures see Tab: Plumbing Fixtures |
Page &P of &N
HIMARS-Detail
| J-1502000-09 | |||||
| PREVENTATIVE MAINTENANCE PROGRAM EQUIPMENT DETAIL | |||||
| MCRC HUNTSVILLE, AL | |||||
| HIMARS MAINTENANCE FACILITY (BUILDING 3506B) | |||||
| Equipment | Designation | Manufacturer | Model | Serial Number | Remarks |
| 1502000 Spec Item 3.2 - HVAC | |||||
| Heat Pump - Split | HP-1 | Daiken Industries | RX09FVJU | E001141 | |
| Heat Pump - Split | HP-2 | Daiken Industries | 2MXS18DVJU | E000704 | |
| Heat Pump - Split | HP-3 | Daiken Industries | RX09FVJU | E001144 | |
| Heat Pump - Split | HP-4 | Daiken Industries | RX15FVJU | E000686 | |
| Fan Coil Unit | AHU-1 | Daiken Industries | FTXS09DVJU | E003809 | |
| Fan Coil Unit | AHU-2 | Daiken Industries | FTXS09DVJU | E004266 | |
| Fan Coil Unit | AHU-3 | Daiken Industries | FTXS15DVJU | E001675 | |
| Fan Coil Unit | AHU-4, AHU-5 | Daiken Industries | CTXS09DVJU | ||
| 1502000 Spec Item 3.2 - WHE | |||||
| Crane - Overhead (monorail), Electric | COE-1 | Hoist - Yale | 7-1/2 ton | ||
| 1502000 Spec Item 3.2 - Miscellaneous Equipment | |||||
| Air Compressor | AC-1 | Ingersoll Rand | 2-2475E5V-FP | 0811240008 | |
| Air Dryer - Refrigerant | ADR-1 | Ingersoll Rand | D451N |
Page &P of &N
Detail - AF
| J-1502000-09 | |||||||||
| PREVENTATIVE MAINTENANCE PROGRAM EQUIPMENT DETAIL | |||||||||
| AIR FILTER (HVAC) | |||||||||
| MCRC HUNTSVILLE, AL | |||||||||
| (FILTER SIZE/QUANTITY SHALL BE FIELD VERIFIED BEFORE PURCHASING REPLACEMENT FILTERS) | |||||||||
| DESIGNATION | EQUIPMENT | FILTER 1 | FILTER 2 | FILTER 3 | FILTER 4 | ||||
| SIZE | QUANTITY | SIZE | QUANTITY | SIZE | QUANTITY | SIZE | QUANTITY | ||
| ADMINISTRATIVE, VMF | |||||||||
| AF-1 | AHU-1 | 16x25x2 | 4 | ||||||
| AF-2 | AHU-2 | 16x25x2 | 4 | ||||||
| AF-3 | RTU-1 | 18x18x2 | 3 | 18x24x2 | 3 | ||||
| AF-4 | RTU-2 | 18x18x2 | 3 | 18x24x2 | 3 | ||||
| AF-5 | ACW-1 | Reuseable | |||||||
| AF-6 | FCU-1 | Reuseable | |||||||
| AF-7 | FCU-2 | Reuseable | |||||||
| AF-8 | FCU-3 | Reuseable | |||||||
| AF-9 | FCU-4 | Reuseable | |||||||
| AF-10 | FCU-5 | Reuseable | |||||||
| AF-11 | FCU-6 | Reuseable | |||||||
| AF-12 | FCU-7 | Reuseable | |||||||
| HIMAR | |||||||||
| AF-1 | AHU-1 | Reuseable | |||||||
| AF-2 | AHU-2 | Reuseable | |||||||
| AF-3 | AHU-3 | Reuseable | |||||||
| AF-4 | AHU-4 | Reuseable | |||||||
| AF-5 | AHU-5 | Reuseable |
Page &P of &N
Detail - PF
| J-1502000-09 | ||
| PREVENTATIVE MAINTENANCE PROGRAM EQUIPMENT DETAIL | ||
| PLUMBING FIXTURE | ||
| MCRC HUNTSVILLE, AL | ||
| FIXTURE | QUANTITY | |
| Sink | 15 | |
| Shower Head | 6 | |
| Toilet | 11 | |
| Urinal | 7 |
Page &P of &N