Index
| J-1502000-10 | |||||
| PREVENTATIVE MAINTENANCE PROGRAM INDEX | |||||
| MCRC MONTGOMERY, AL | |||||
| (For Manufacturer, model and serial number of equipment see Equipment Detail tab) | |||||
| Equipment | Designation | Quantity | Location | Contractor Developed PM Program Checklist Sheet (Note 6) | Frequency of Inspection |
| 1502000 Spec Item 3.2 - HVAC | |||||
| Air Conditioner - Split System | ACS-1 | 1 | Roof (Above Armory, Room 300) | Semiannual | |
| Air Filter (HVAC) | AF-1 through AF-7 | 7 | See Tab: Detail - Air Filter | Every Other Month | |
| Air Handling Unit | AHU-1, AHU-2, AHU-3, AHU-4 | 4 | AHU-1 (Rm 144), AHU-2 (Rm 200), AHU-3 (Rm 174), AHU-4 (Maintenance Shop, Weight Room 400) | Semiannual | |
| Chiller - Air Cooled | ACC-1 | 1 | Outside, adjacent to Drill Hall 174 | X | As required by manufacturer, except coils shall be cleaned semiannually |
| Coil-Duct (electric heat) | DH-1 | 1 | Maintenance Building (new), Bay | Annual | |
| Damper (motorized) | D-1 through D-5 | 5 | D-1, D-2 (AHU-1), D-3, D-4 (AHU-2), D-5 (AHU-3) | Semiannual | |
| Damper (motorized ) | D-6 (Exhaust, wall), D-7 (OA intake, duct), D-8 (return air, duct) | 3 | Maintenance Building (new), Bay | Quarterly | |
| Fan (duct) | SF-1 | 1 | Maintenance Building (new), Bay | Semiannual | |
| Fan (roof) | EF-1 through EF-4 | 4 | Roof | Quarterly | |
| Fan (wall) | EF-5 through EF-8, SF-1 through SF-4, EF-9, EF-10 | 7 | EF-5 through EF-8, SF-1 through SF-4 (Attic), EF-9 (Maintenance Shop, Room 401), EF-10 (Hazmat Locker) | Semiannual | |
| Fan Coil Unit | FCU-1 | 1 | Armory, Room 301 | Annual (spring) | |
| Fan Coil Unit-Computer | CRU-1 | 1 | Armory, Room 300 | Semiannual | |
| Heat Pump - Split | HPS-1, CU-4 | 2 | HPS-1 (Roof, above Armory 301), CU-4 (Outside, adj to Maintenance Shop, Weight Room 400) | Semiannual | |
| System Water-Chilled Water | CW-1 | 1 | Room 144 | X | Annual (Note 7) |
| Terminal-VAV | VAV-1 thru VAV-33 | 33 | See J-1502000-02 | Annual | |
| 1502000 Spec Item 3.2 - Electrical Systems | |||||
| Lighting (exterior) | Lighting | Attached to buildings and pole lighting | Quarterly | ||
| Lighting (interior) | Lighting | Administrative Building, Maintenance Building, Maintenance Shop, Armory, Hazmat Locker | Quarterly | ||
| Panelboard | PB-HDP, PB-MDP, PB-HA, PB-HB, PB-HC, PB-HD, PB-LP1, PB-LP2, PB-LP3, PB-LP4, PB-LP5, PB-LP6, PB-M, PB- LA, PB-1, PB-Hazmat | 16 | PB-HDP (outside, adj to room 144), PB-MDP (Room 141), PB-HA (Room 108), PB-HB (Room 131), PB-HC (Corridor 135), PB-HD (Room 164), PB-LP1 (Drill Hall 174), PB-LP2 (Corridor 135), PB-LP3 (Corridor 118), PB-LP4 (Room 158), PB-LP5 (Stair Well 115), PB-LP6 (Maintenance Shop, Weight Room 400), PB-M (Maintenance Shop, Room 402), PB- LA (Armory, Room 300), PB-1 (Maintenance Building (new), Bay), PB-HazMat (HazMat Lkr) | Annual | |
| 1502000 Spec Item 3.2 - Fire Protection | |||||
| FP - Detection and Alarm System | FP - Detection | Administrative Building | Annual | ||
| Fire Extinguisher (portable)-Monthly Inspection | FE-1 through FE-15 | 15 | FE-1 (Corridor 102), FE-2 (Corridor 103), FE-3 (Corridor 104), FE-4 (Corridor 118), FE-5 (Corridor 128), FE-6 (Corridor 134), FE-7 (Corridor 134), FE-8 (Corridor 143), FE-9 (Corriidor 146), FE-10 (Room 156), FE-11 (Corridor 168), FE-12 (Corridor 171), FE-13 (Drill Hall 174), FE-14 Drill Hall 174), FE-15 (Maintenance Building, Rm 402) | Monthly | |
| Fire Extinguisher (portable)-Annual Maintenance | FE-1 through FE-15 | 15 | FE-1 (Corridor 102), FE-2 (Corridor 103), FE-3 (Corridor 104), FE-4 (Corridor 118), FE-5 (Corridor 128), FE-6 (Corridor 134), FE-7 (Corridor 134), FE-8 (Corridor 143), FE-9 (Corriidor 146), FE-10 (Room 156), FE-11 (Corridor 168), FE-12 (Corridor 171), FE-13 (Drill Hall 174), FE-14 Drill Hall 174), FE-15 (Maintenance Building, Rm 402) | Annual | |
| Fire Sprinkler, Dry Chemical | FSC-1 | 1 | HazMat Locker | Monthly | |
| 1502000 Spec Item 3.2 - Miscellaneous Equipment | |||||
| Air Compressor | AC-1, AC-2 | 2 | AC-1 ( Maintenance Shop, Room 402), AC-2 (Maintenance Building (new), Bay) | Semiannual | |
| Door-Overhead (manual) | DR-1, DR-2, DR-3 | 3 | DR-1 (Office 119), DR-2 (Maintenance Shop, Room 401), DR-3 (Maintenance Shop, Room 402) | Semiannual | |
| Door-Overhead (motorized) | DR-4 | 1 | Maintenance Building (new), Bay | Semiannual | |
| Drinking Fountain | DF-1, DF-2 | 2 | DF-1 (Corridor 128), DF-2 (Drill Hall 174) | Annual | |
| Emergency Eyewash & Shower | EES-1 | 1 | Maintenance Shop, Room 402 | Monthly | |
| Gutters/Down Spouts Cleaning | G-1, G-2 | 1 | G-1 (Administrative Building), G-2 (Maintenance Building (new)) | Annual | |
| Plumbing Fixtures (by room) | PF-1 through PF-15 | 15 | PF-1 (RM 112), PF-2 (Rm 113), PF-3 (Rm 124), PF-4 (Rm 125), PF-5 (Rm 126), PF-6 (Rm 127), PF-7 (Rm 129), PF-8 (Rm 132), PF-9 (Rm 153), PF-10, (Rm 154), PF-11 (Rm 155), PF-12 (Rm 160), PF-13 (Rm 161), PF-14 (Maintenance Shop, Rm 402), PF-15 (Maintenance Shop, Exterior) | Semiannual | |
| Pump (chilled) | P-1, P-2 | 2 | Room 144 | Semiannual | |
| Slide Gate Operator & Entry System | SGO-1. SGO-2 | 2 | Front Gate | Semiannual | |
| Water Heater-Electric | WH-1 through WH-6 | 6 | WH-1, WH-2, WH-3 (Room 131), WH-4 (Maintenance Shop, Room 402), WH-5 (Room 113), WH-6 (Maintenance Building (new)) | Annual | |
| NOTES | |||||
| Note 1 - Equipment listed without a building name is located in the Administrative building | |||||
| Note 2 - ACS-1 linked to CRU-1 | |||||
| Note 3 - HPS-1 linked to FCU-1 | |||||
| Note 4 - CU-4 linked to AHU-4 | |||||
| Note 5 - HVAC equipment shall be inspected in the spring or fall unless otherwise noted | |||||
| Note 6 - If blank, Government will provide PM Program checklist sheet | |||||
| Note 7 -Shall be treated/tested after repairs/leaks resulting in refilling of the system | |||||
| Note 8 - For quantity/size of air filters (HVAC) see Tab: Air Filters (HVAC) | |||||
| Note 9 - For quantity of plumbing fixtures see Tab: Plumbing Fixtures |
Page &P of &N
Detail
| J-1502000-10 | |||||
| PREVENTATIVE MAINTENANCE PROGRAM EQUIPMENT DETAIL | |||||
| MCRC MONTGOMERY, AL | |||||
| Equipment | Designation | Manufacturer | Model | Serial Number | Remarks |
| 1502000 Spec Item 3.2 - HVAC | |||||
| Air Conditioner - Split System | ACS-1 | Liebert | PFH020A-PL3 | 0341N83310 | |
| Air Handling Unit | AHU-1 | Trane | M Series Climate Changer | 14,500 CFM, 529.7 MBTUH total cooling, 101 gpm, 15 HP | |
| Air Handling Unit | AHU-2 | Trane | M Series Climate Changer | 6,150 CFM, 227.9 MBTUH total cooling, 45 gpm, 5 HP | |
| Air Handling Unit | AHU-3 | Trane | M Series Climate Changer | 5,250 CFM, 177.3 MBTUH total cooling, 35 gpm, 5 HP | |
| Air Handling Unit | AHU-4 | Trane | TWE024P130B0 | 4251X7P2V | DX coil Electric heat |
| Chiller - Air Cooled | ACC-1 | Trane | RTAA0704XQ01A3D0B | U04B04488 | 70 ton design capacity, 180 GPM, 45 F leaving water temperature, 2 compressors |
| Fan Coil Unit | FCU-1 | Rheem | |||
| Fan Coil Unit-Computer | CRU-1 | Liebert | DME020E-PH3 | 0341N83404 | 870 CFM, 16,700 BTUH total cooling, 2.7 KW reheat, 31 lbs/hr humidifer |
| Fan (duct) | SF-1 | Loren Cook Co | |||
| Fan (roof) | EF-1 | Greenheck Fan Corp | 6B-101-4X-QD-R3 | 04A23863 | 800 CFM, Roof top, Belt driven, 1/4 HP |
| Fan (roof) | EF-2 | Greenheck Fan Corp | 6B-101-4X-QD-R3 | 04A23864 | 1000 CFM, Roof top, Belt driven, 1/4 HP |
| Fan (roof) | EF-3 | Greenheck Fan Corp | 6B-081-6 | 04B06902 | 400 CFM, Roof top, Belt driven, 1/6 HP |
| Fan (roof) | EF-4 | Greenheck Fan Corp | 6B-081-6 | 04B05777 | 300 CFM, Roof top, Belt driven, 1/6 HP |
| Fan (wall) | EF-5 | Greenheck Fan Corp | 2800 CFM, Wall propeller, Direct drive, 1/4 HP | ||
| Fan (wall) | EF-6 | Greenheck Fan Corp | 2800 CFM, Wall propeller, Direct drive, 1/4 HP | ||
| Fan (wall) | EF-7 | Greenheck Fan Corp | 2800 CFM, Wall propeller, Direct drive, 1/4 HP | ||
| Fan (wall) | EF-8 | Greenheck Fan Corp | SE1-16-426-B6 | 04B04793 | 1700 CFM, Wall propeller, Direct drive, 1/6 HP |
| Fan (wall) | SF-1 | Greenheck Fan Corp | 2800 CFM, Wall propeller, Direct drive, 1/4 HP | ||
| Fan (wall) | SF-2 | Greenheck Fan Corp | 2800 CFM, Wall propeller, Direct drive, 1/4 HP | ||
| Fan (wall) | SF-3 | Greenheck Fan Corp | 2800 CFM, Wall propeller, Direct drive, 1/4 HP | ||
| Fan (wall) | SF-4 | Greenheck Fan Corp | SS1-16-426-B6 | 04B04801 | 1700 CFM, Wall propeller, Direct drive, 1/6 HP |
| Heat Pump - Split | HPS-1 | Rheem | RPKA-018JAZ | 5343M41957157 | |
| Heat Pump - Split | CU-4 | Trane | 2TWB0024A1000AB | 4251NRA4F | |
| Terminal-VAV | VAV-1 thru VAV-33 | Trane | VariTrane Single Duct | ||
| 1502000 Spec Item 3.2 - Miscellaneous Equipment | |||||
| Air Compressor | AC-1 | Curtis-Toledo Inc | Curtis Master Line | Electric, Belt drive | |
| Air Compressor | AC-2 | Curtis-Toledo Inc | 0V907 | Electric, Belt drive | |
| Slide Gate Operator | SGO-1 | Doorking, Inc | Model 9150 | ||
| Slide Gate Operator & Entry System | SGO-2 | Doorking, Inc | Model 9150-080 | ||
| Water Heater-Electric | WH-1 | A.O. Smith | DIVE_120A_916 | MIL030022649 | 119 Gal Tank |
| Water Heater-Electric | WH-2 | A.O. Smith | DIVE_120A_916 | MIL030022650 | 119 Gal Tank |
| Water Heater-Electric | WH-3 | A.O. Smith | DIVE_120A_916 | MIL030016653 | 119 Gal Tank |
| Water Heater-Electric | WHE-4 | A.O. Smith | DVE_80A_916 | MM030016652 | |
| Water Heater-Electric | WH-5 | Rheem | 666H-400 | R_0780M79847 | 40 Gal Tank |
| Water Heater-Electric | WH-6 | AO Smith | ECJN 40 200 | 0905A020608 |
Page &P of &N
Detail - AF
| J-1502000-10 | |||||||||
| PREVENTATIVE MAINTENANCE PROGRAM EQUIPMENT DETAIL | |||||||||
| AIR FILTER (HVAC) | |||||||||
| MCRC MONTGOMERY, AL | |||||||||
| (FILTER SIZE/QUANTITY SHALL BE FIELD VERIFIED BEFORE PURCHASING REPLACEMENT FILTERS) | |||||||||
| DESIGNATION | EQUIPMENT | FILTER 1 | FILTER 2 | FILTER 3 | FILTER 4 | ||||
| SIZE | QUANTITY | SIZE | QUANTITY | SIZE | QUANTITY | SIZE | QUANTITY | ||
| AF-1 | AHU-1 | 16x24x2 | 2 | 16x20x2 | 1 | 20x24x2 | 2 | 20x20x2 | 1 |
| AF-2 | AHU-2 | 20x24x2 | 4 | 24x24x2 | 4 | ||||
| AF-3 | AHU-3 | 20x20x2 | 6 | ||||||
| AF-4 | AHU-4 | 20x24x2 | 4 | 24x24x2 | 4 | ||||
| AF-5 | CRU-1 | Reusable | |||||||
| AF-6 | FCU-1 | 20x20x1 | 1 | ||||||
| AF-7 | SF-1 |
Page &P of &N
Detail - PF
| J-1502000-10 | ||
| PREVENTATIVE MAINTENANCE PROGRAM EQUIPMENT DETAIL | ||
| PLUMBING FIXTURE | ||
| MCRC MONTGOMERY AL | ||
| FIXTURE | QUANTITY | |
| Sink | 14 | |
| Shower Head | 10 | |
| Toilet | 10 | |
| Urinal | 6 |