W912HN-21-B-3003_DRAWINGS_VOL3_AMD2.PDF

PDF 266 KB Posted

Attached to
PN 55516 ADVANCED INDIVIDUAL TRANING (AIT) COMPLEX BARRACKS PHASE 3, FORT GORDON
Solicitation number
W912HN21B3003
Issued by

About this file

This document summarizes a federal solicitation for construction services. The solicitation seeks the construction of an Advanced Individual Training Complex at Fort Gordon, including a battalion headquarters, barracks to house 600 soldiers, a running track, physical training facilities, building information systems, fire protection and alarm systems, video surveillance and intrusion detection. Supporting facilities such as utilities, site development, parking and landscaping are also required. The scope requires compliance with Department of Defense antiterrorism standards and accessibility requirements. Sustainability, energy efficiency, and cyber security measures must be incorporated. The project has an estimated value between $25-100 million and a period of performance of 720 calendar days. Bids will be evaluated using sealed bidding procedures in accordance with the FAR.

View the file

Other files

File Type Posted
C.04. W912HN21B3003 AIT Abstract-s1_Page_2.jpg JPG image
C.04. W912HN21B3003 AIT Abstract-s1_Page_1.jpg JPG image
AIT Bid Opening Roster.jpg JPG image
B.08. W912HN21B30030004 Amendment.pdf PDF
B.08. 21B3003_Amd04_Specs_Vol5_BNHQ.PDF PDF
B.08. 21B3003_Amd04_Specs_Vol4_BCOF.PDF PDF
B.08. 21B3003_Amd04_Specs_Vol1_BCOF.PDF PDF
B.08. W912HN-21-B-3003_DRAWINGS_VOL2_AMD4.pdf PDF
B.08. 21B3003_Amd04_Specs_Vol2_BCOF.PDF PDF
B.08. 21B3003-Amd04_Specs_Vol6_BNHQ.PDF PDF
B.08. W912HN21B30030004 Conformed Copy.pdf PDF
21B3003_Amd03_Specs_Vol5_BNHQ Rev3.PDF PDF
21B3003_Amd03_Specs_Vol6_BNHQ Rev3.PDF PDF
W912HN-21-B-3003_DRAWINGS_VOL2_AMD3.pdf PDF
W912HN-21-B-3003_DRAWINGS_VOL3_AMD3.PDF PDF
W912HN-21-B-3003_DRAWINGS_VOL4_AMD3.PDF PDF
W912HN-21-B-3003_DRAWINGS_VOL1_AMD3.pdf PDF
B.08. 21B3003_Amd03_Specs_Vol2_BCOF Rev3.PDF PDF
B.08. 21B3003_Amd03_Specs_Vol3_BCOF Rev2.PDF PDF
B.08. 21B3003_Amd03_Specs_Vol1_BCOF Rev3.PDF PDF
B.08. W912HN21B3003 0003 Conformed Copy.pdf PDF
B.08. 21B3003_Amd03_Specs_Vol4_BCOF Rev3.PDF PDF
B.08. W912HN21B3003 0003 AMD.pdf PDF
W912HN-21-B-3003_DRAWINGS_VOL4_AMD2.PDF PDF
21B3003_Specs_Vol6_BNHQ Rev2.PDF PDF
21B3003_Specs_Vol5_BNHQ Rev2.PDF PDF
21B3003_Specs_Vol3_BCOF Rev1.PDF PDF
W912HN21B3003 0002 Conformed copy.pdf PDF
21B3003_Specs_Vol2_BCOF Rev2.PDF PDF
W912HN-21-B-3003_DRAWINGS_VOL2_AMD2.pdf PDF
21B3003_Specs_Vol4_BCOF Rev2.PDF PDF
W912HN21B3003 0002 Amendment.pdf PDF
21B3003_Specs_Vol1_BCOF Rev2.PDF PDF
W912HN-21-B-3003_DRAWINGS_VOL3_AMD1.PDF PDF
21B3003_Specs_Vol2_BCOF_Rev1.PDF PDF
B.08. W912HN21B30030001 Site Visit IMG_0858.JPG JPG image
W912HN21B30030001 Amendment.pdf PDF
W912HN-21-B-3003_DRAWINGS_VOL1_AMD1.pdf PDF
21B3003_Specs_Vol5_BNHQ_Rev1.PDF PDF
W912HN21B3003 0001 Conformed Copy.pdf PDF
21B3003_Specs_Vol6_BNHQ_Rev1.PDF PDF
20B3003_Specs_Vol1_BCOF_Rev1.PDF PDF
21B3003_Specs_Vol4_BCOF_Rev1.PDF PDF
AIT Phase III Site Visit Sign-In Sheet_02Mar2021.pdf PDF
AIT Phase III Site Plans.pdf PDF
W912HN-21-B-3003_DRAWINGS_VOL2_AMD1.pdf PDF
20B3003_Specs_Vol1_BCOF.PDF PDF
21B3003_Specs_Vol7_Apps.PDF PDF
21B3003_Specs_Vol5_BNHQ.PDF PDF
21B3003_Specs_Vol4_BCOF.PDF PDF
Show 40 more

Latest 50 of 58 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PLUMBING LEGENDPLUMBING GENERAL NOTES

1. FURNISH ALL LABOR, INSTALL ALL MATERIALS AND EQUIPMENT, AND INCLUDE ALL SERVICES AND INCIDENTALS PROPER TO THE INSTALLATION OF WORK INVOLVED FOR A COMPLETE AND OPERATING FACILITY.

2. CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES, SPECS AND DRAWINGS.

3. PROVIDE CLEARANCES AROUND EQUIPMENT AS RECOMMENDED BY MANUFACTURER. COORDINATE EQUIPMENT

ELECTRICAL REQUIREMENTS WITH ELECTRICAL DRAWINGS.

4. THE PLUMBING DRAWINGS ARE GENERALLY DIAGRAMMATIC AND SHOW THE RELATIONSHIP BETWEEN EQUIPMENT AND CONNECTIONS. DO NOT SCALE THE DRAWINGS FOR EXACT SIZE OR LOCATIONS. DETAILS AND ASSEMBLY

DRAWINGS ARE SPECIFIC AND SHALL BE ADHERED TO.

5. THE PLUMBING SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS, SPECIFICATIONS, NFPA 54 AND THE INTERNATIONAL PLUMBING CODE.

6. ALL BUILDINGS SHALL BE DESIGNED FOR SEISMIC DESIGN CATEGORY "B".

7. CONCRETE HOUSEKEEPING PAD SIZES SHALL BE COORDINATED WITH INSTALLED EQUIPMENT.

8. COORDINATE VENT THRU ROOF AND WATER HEATER INTAKE/FLUE PIPING PENETRATIONS THRU ROOF WITH

ROOFING CONTRACTOR. FLASHING SHALL BE BY ROOFING CONTRACTOR.

9. REFER TO SCHEDULES, DETAILS AND DIAGRAMS FOR PIPE AND PIPE SIZES NOT SHOWN.

10. PROVIDE EXPANSION JOINTS IN PIPING WHEN CROSSING THE BUILDING SEISMIC JOINT BETWEEN AREAS B AND D.

EXPANSION JOINTS SHALL PROVIDE AT LEAST 3 INCHES OF MOVEMENT. EXPANSION JOINTS SHALL BE OF EITHER THE BRAIDED HOSE DOGLEG ASSEMBLY OR BRAIDED HOSE V LOOP TYPE. REFER TO SPECIFICATION SECTION 23 05 48.19.

SANITARY SEWER

SANITARY VENT

CONDENSATE DRAIN (SEE MP-PLATES)

DOMESTIC COLD WATER

DOMESTIC HOT WATER

DOMESTIC HOT WATER RECIRCULATED

GATE VALVE

BALL VALVE

A.S.M.E. RATED T&P RELIEF VALVE

CHECK VALVE

PRESSURE REDUCING VALVE

PIPE DROP

PIPE RISE

FLANGE

UNION

HOSE BIBB/WALL HYDRANT

PIPE TEE

PIPE ELBOW

DRAWING NOTE

PLUBMING EQUIPMENT TAG

ABOVE FINISHED FLOOR

ABOVE FINISHED GRADE

BELOW FINISHED FLOOR

BELOW FINISHED GRADE

BOTTOM OF PIPE

CONDENSATE DRAIN

CLEANOUT

EXTERIOR CLEANOUT

FLOOR CLEANOUT

FLOOR DRAIN

HOSE BIBB

HUB DRAIN

INVERT

REDUCED PRESSURE PRINCIPAL BACKFLOW PREVENTER

SANITARY SEWER

VENT

VENT THRU ROOF

WALL HYDRANT

WATER HAMMER ARRESTOR

- APPLIES TO ALL P-SERIES SHEETS- APPLIES TO ALL P-SERIES SHEETS

X" SS

X" V

X" CD

X" CW

X" HW

X" HWR

P - #

AFF

AFG

BFF

BFG

BOP

CD

CO

ECO

FCO

FD

HB

HD

INV

RPBP

SS

V

VTR

WH

WHA

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\k6endles\Desktop\Tele-Work Revit Projects\Gor0402 (PN55516)\FY20PN55516_BKS_PLUMB_R18_TW Current.rvt3/16/2021 2:14:15 PM

N O

VE

M

BE

R

W

2H N

-2 1-

B-

L.

S

AL

AS

L.

S

AL

AS

S.

B

AR

BI

N A

1-

-0

P-001

PL

U

M

BI

N G

L

EG

EN

D

SA

VA

N N

AH

D

IS

TR

IC

T

W . O

G

LE

TH

O

R

PE

A

VE

SA

VA

N

N

AH

, G A

FO

R

T G

O R

D O

N , G

EO

R

G

IA

AI

T

BA

R

R

AC

KS

C

O M

PL

EX

, P H

FY

, P

N

VO

LU

M E

-B

AR

R

AC

KS

(P

LU

M

BI

N G

, M

EC

H

AN

IC

AL

, E

LE

C

TR

IC

AL

, A N

D

TE

LE

C

O M

M U

N

IC

AT

IO

N

K.

D

IX

O

N

READY TO ADVERTISE (RTA)

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

3/

/2

ELECTRICAL LEGEND

LED LUMINAIRES. SEE LIGHT FIXTURE SCHEDULE, DETAILS, AND

SPECIFICATIONS FOR ADDITIONAL INFORMATION.

LOWER CASE DENOTES THE DEVICE THAT CONTROLS FIXTURE

LUMINAIRE TYPE DESIGNATION

SYMBOL DENOTES GENERAL TYPE OF LUMINAIRE

UNSWITCHED NIGHT LIGHT (ON 24

HOURS)

a A2

NT

T

LCP

OS

DS

LVX

ELI

PC

LIGHTING AND LIGHTING CONTROLS SYSTEM LEGEND

v fan

LED LUMINAIRES WITH EMERGENCY DRIVERS OR CONNECTED TO AN

EMERGENCY LIGHTING INVERTER

WALL MOUNTED LED LUMINAIRE.

WALL MOUNTED LED LUMINAIRE WITH EMERGENCY DRIVER.

WALL MOUNTED LED LUMINAIRES.

SUSPENDED LED LUMINAIRE.

SUSPENDED LED LUMINAIRE WITH INTEGRAL EMERGENCY

DRIVER.

EXIT LIGHT, CEILING MOUNTED, SHADING INDICATES FACES.

PROVIDE DIRECTIONAL ARROWS WHEN INDICATED.

EXIT LIGHT, WALL MOUNTED, SHADING INDICATES FACES. PROVIDE

DIRECTIONAL ARROWS WHEN INDICATED. MOUNT BOTTOM OF

FIXTURE 6" ABOVE TOP OF DOOR UNLESS OTHERWISE INDICATED.

WALL SWITCH, SINGLE POLE, 20A SWITCH. WHERE SUBSCRIPT IS

PRESENT, IT DENOTES THE FOLLOWING:

3 - THREE WAY SWITCH.

4 - FOUR WAY SWITCH.

a - SINGLE LOWER CASE LETTER (EXCEPT LETTER "m")

DENOTES THE SWITCH THAT CONTROLS THE FIXTURES.

WP - WEATHERPROOF (GASKETED).

MOTOR RATED SWITCH FOR CEILING FAN.

WALL SWITCH SENSOR, LINE VOLTAGE. SUBSCRIPT "v" DENOTES SIGNLE RELAY, SUBSCRIPT "dv" DENOTES DUAL RELAY, DUAL SWITCH.

DIGITAL TIME SWITCH, LOW VOLTAGE.

LOW VOLTAGE, MULTI-BUTTON WALLSTATION CONNECTED TO ROOM

CONTROLLER. SUBSCRIPTS ARE DENOTED VIA DETAILS.

OCCUPANCY SENSOR. WALL MOUNTED, DUAL TECHNOLOGY

ULTRASONIC / PIR) SENSOR UNLESS OTHERWISE INDICATED.

SUBSCRIPT "P" INDICATES PIR ONLY.

OCCUPANCY SENSOR. CEILING MOUNTED OR SUSPENDED AT HEIGHT

OF LIGHTING FIXUTE. ULTRASONIC SENSOR UOI.

DAYLIGHT SENSOR. CEILING MOUNTED OR SUSPENDED AT HEIGHT

OF LIGHTING FIXTURE.

EXTERIOR PHOTOCELL.

LIGHTING CONTROL PANEL (LCP).

EMERGENCY LIGHTING INVERTER.

# INDICATES LIGHTING CONTROL STRATEGY. SEE SHEET EL602.#

LED LUMINAIRE WITH ASYMMETRIC LIGHT DISTRIBTION. ARROW

DENOTES DIRECTION OF LIGHT DISTRIBUTION..

dv

M

C

J

NEMA 5-20R CEILING MOUNTED DUPLEX RECEPTACLE OUTLET.

JUNCTION BOX, WALL MOUNTED. MH = 1'-6" UNLESS OTHERWISE

NOTED OR INDICATED.

MOTOR RATED SWITCH

MOTOR DISCONNECT/SAFETY SWITCH. SWITCH SHALL BE RATED

30/3/NF/1 UNLESS OTHERWISE INDICATED WHERE:

'30' DENOTES SWITCH AMPERE RATING;

'3' DENOTES NUMBER OF POLES;

'NF' DENOTES NON-FUSED;

('F##' DENOTES FUSED AND FUSE RATING);

'1' DENOTES SWITCH ENCLOSURE'S NEAMA RATING.

FUSE RATING (WHEN INDICATED) SHALL BE IN ACCORDANCE WITH

EQUIPMENT MANUFACTURER'S RECOMMENDATIONS.

T #

SPD

PANELBOARD - MH IN ACCORDANCE WITH NEC

DRY-TYPE TRANSFORMER

SURGE PROTECTIVE DEVICE

NEMA 5-20R DOUBLE DUPLEX (QUADRAPLEX) RECEPTACLE, MOUNTED

IN 2-GANG FLOOR BOX.

NEMA 5-20R DUPLEX RECEPTACLE, MH=18" UOI. SUBSCRIPT 'X' (WHERE

PRESENT) DENOTES THE FOLLOWING:

G - DENOTES GROUND FAULT CIRCUIT INTERRUPTER (GFCI)

RECEPTACLE

WP - DENOTES GFCI RECEPTACLE WITH WEATHER PROOF

WHILE-IN-USE HOUSING.

GC - DENOTES GFCI RECEPTACLE WITH BOTTOM OF

RECEPTACLE MOUNTED 2" ABOVE COUNTERTOP

BACKSPLASH.

E - DENOTES RECEPTACLE FOR ELECTRIC WATER COOLER.

COORDINATE MOUNTING WITH EQUIPMENT PROVIDED.

GROUND FAULT PROTECTION INDICATED BY NOTE.

TV - DENOTES RECPTACLE FOR TELEVISION. MOUNT ADJACENT

TO CATV OUTLET.

OS - DENOTES RECEPTACLE CONTROLLED BY ROOM

OCCUPANCY SENSORS VIA RECEPTACLE-RATED

SWITCHPACK. OUTLET SHALL BE MARKED IN ACCORDANCE

WITH NEC, ARTICLE 406.3(E).

R - DENOTES RECEPTACLE MOUNTED ABOVE

COMMUNICATIONS RACK. SEE DETAIL 1 ON EP501.

V - DENOTES RECEPTACLE FOR VENDING MACHINE; MOUNTING

HEIGHT 48" AFF; GFCI RECEPTACLE;

POWER & ELECTRICAL SYSTEMS LEGEND

FIRE PUMP MOTOR CONNECTION

MOTOR CONNECTION JUNCTION BOX. M

NEMA TYPE 14-30R FOR LAUNDRY DRYER EQUIPMENT. PROVIDE 3#10, 1

#12G IN 1/2" C.

NEMA TYPE 6-20R RECEPTACLE MOUNTED ABOVE COMMUNICATIONS

RACK PER DETAIL 1 ON EP501.

NEMA 5-20R DOUBLE DUPLEX RECEPTACLE, MH=18" UOI. SUBSCRIPTS

"X" IDENTIFIED FOR DUPLEX RECEPTACLES ARE APPLICABLE TO

DOUBLE DUPLEX (QUADRAPLEX) RECEPTACLES.

RECESSED 4-GANG POWER AND COMMUNICATIONS FLOOR BOX.

PROVIDE (2) NEMA 5-20R DUPLEX RECEPTACLES IN THE POWER

COMPARTMENT OF EACH FLOOR BOX.

RECESSED 8-GANG POWER AND COMMUNICATIONS FLOOR BOX.

PROVIDE (4) NEMA 5-20R DUPLEX RECEPTACLES IN THE POWER

COMPARTMENT OF EACH FLOOR BOX.

D R

TTB

CTB

FIRE-RETARDANT PLYWOOD BACKBOARD WITH NO ADDED UREA

FORMALDEHYDE. SEE SPECIFICATIONS 01 33 29 FOR FSC

CERTIFICATION REQUIREMENTS.

ps 3-POSITION SWITCH FOR PROJECTOR SCREEN. MH = 46" AFF UOI.

NEMA 5-20R SIMPLEX RECEPTACLE, MH=18" UOI. SUBSCRIPTS "X"

IDENTIFIED FOR DUPLEX RECEPTACLES ARE APPLICABLE TO SIMPLEX

RECEPTACLES.

GENERAL NOTES

1. SEE PLATE E-002 FOR ABBREVIATIONS AND TYPICAL MOUNTING HEIGHT

DIAGRAM.

2. MOUNTING HEIGHT, UNLESS OTHERWISE NOTED, IS TO CENTER LINE OF

EQUIPMENT.

3. PRESENSE OF SYMBOLS IN LEGEND DOES NOT INDICATE THAT A DEVICE OR

SYSTEM IS REQUIRED IN FACILITY CONSTRUCTION.

4. MOUNT OUTLET BOXES SO THAT NONE OCCUR BACK TO BACK IN WALLS.

5. MECHANICAL EQUIPMENT IS SHOWN IN APPROXIMATE LOCATIONS. FOR

EXACT LOCATIONS OF MECHANICAL EQUIPMENT AND PIPING, SEE

MECHANICAL DRAWINGS. PROVIDE DISCONNECT SWITCHES AS REQUIRED BY

THE NATIONAL ELECTRICAL CODE EVEN IF NOT INDICATED ON THE

ELECTRICAL DRAWINGS.

6. COORDINATE THE LOCATIONS AND MOUNTING HEIGHTS OF LIGHTING

FIXTURES IN MECHANICAL AND ELECTRICAL ROOMS WITH THE FINAL

LOCATIONS OF PIPES, DUCTS AND OTHER EQUIPMENT FOR BEST

ARRANGEMENT. FIXTURES SHALL BE EASILY ACCESSIBLE FOR RELAMPING.

7. CONDUCTOR AND CONDUIT SIZES ARE BASED ON COPPER CONDUCTORS

WITH THWN INSULATION IN EMT CONDUIT. CIRCUIT BREAKERS, TERMINALS,

ETC. SHALL BE RATED AND MARKED FOR 75 DEGREES MINIMUM. THE

CONTRACTOR SHALL ADJUST CONDUIT SIZES BASED ON ACTUAL TYPE OF

CONDUCTORS AND CONDUIT INSTALLED.

8. CIRCUIT NUMBERS ARE SHOWN ADJACENT TO ELECTRICAL DEVICES.

WIRING SHALL BE IN ACCORDANCE WITH THE MANUFACTURERS

RECOMMENDATIONS AND/OR REQUIREMENTS.

9. ALL WIRING SHALL BE CONCEALED UNLESS INDICATED OTHERWISE.

CONDUITS SHALL NOT BE RUN IN ANY UL RATED SLAB.

10. REVISE PANELBOARD SCHEDULES ON AS-BUILT-DRAWING AND PANEL

DIRECTORIES TO REFLECT FINAL INSTALLATION CONDITIONS.

11. SEAL PENETRATIONS THROUGH ROOFS, CEILINGS, FLOORS, WALLS AND

FIRE WALLS TO MAINTAIN THE INTEGRITY OF THE AIR BARRIER, FIRE AND

ACOUSTIC RATINGS OF THE ROOF, CEILINGS, WALLS AND FLOORS.

12. COMPONENTS WHICH CONSTITUTE AN ELECTRICAL SYSTEM SHALL BE

FULLY COMPATIBLE WITH ONE ANOTHER AND SHALL BE APPROVED BY THE

VARIOUS MANUFACTURERS FOR USE WITH ALL OTHER COMPONENTS WITHIN

THE SYSTEM. (ONE EXAMPLE OF AN ELECTRICAL SYSTEM IS THE BUILDING

LIGHTING SYSTEM COMPRISED OF FIXTURES, LAMPS, SWITCHES, BALLASTS,

OCCUPANCY SENSORS AND DIMMING EQUIPMENT).

13. LOCATE ALL RACEWAYS TO AVOID INTERFERENCE WITH DUCTS, PIPES,

MECHANICAL EQUIPMENT, WITH REMOVAL OF CEILING TILES, OR WITH

ACCESS TO EQUIPMENT WHICH REQUIRES PERIODIC ADJUSTMENT OR

MAINTENANCE.

14. PROVIDE NAMEPLATES ON THE EXTERIOR OF ALL ELECTRICAL PANELS

AND ENCLOSURES AS FOLLOWS: DEVICE ID, DEVICE RATING, POWER SOURCE,

ARC FAULT DATA. ARC-FAULT DATA SHALL MEET 2015 NFPA 70E

REQUIREMENTS.

15. FOR DISCONNECT SWITCHES AND MOTOR STARTERS THE TOP LINE SHALL

BE THE NAME/DESIGNATION OF THE EQUIPMENT BEING FED BY THE

SWITCH/STARTER.

16. PROVIDE SEPARATE NEUTRALS FOR EACH CIRCUIT UTILIZING A NEUTRAL

CONDUCTOR. MULTI-WIRE CIRCUITS ARE NOT ALLOWED.

17. PROVIDE EQUIVALENT CONDUIT PATHWAYS WHERE CABLE TRAY IS

INTERRUPTED BY NONACCESSIBLE CEILINGS.

18. THE INTERRUPTING RATING OF THE PANELBOARDS AND ELECTRICAL

EQUIPMENT SHALL BE INCREASED TO THE NEXT AVAILABLE RATING WHERE

THERE IS NOT A RATING THAT IS EQUAL TO THE EQUIPMENT'S LISTED SHORT

CIRCUIT RATING.

19. PROVIDE GROUNDING CONDUCTORS IN ALL CONDUITS.

20. RACEWAYS CROSSING STRUCTURAL EXPANSION JOINTS OR SEISMIC

JOINTS SHALL BE PROVIDED WITH EXPANSION FITTINGS TO COMPENSATE

FOR THE BUILDING EXPANSION AND CONTRACTION AND TO PROVIDE FOR

CONTINUITY OF GROUNDING. EXPANSION FITTINGS SHALL HAVE AN INTEGRAL

BONDING JUMPER. ONLY FITTING LISTED AS EXPANSION TYPES WILL BE

CONSIDERED SUITABLE.

21. RECEPTACLES THAT HAVE GFI PROTECTION ARE TO BE WIRED SUCH

THAT THE LOSS OF POWER ON ONE RECEPTACLE DOES NOT AFFECT

DOWNSTREAM RECEPTACLES.

22. NOTE REMOVED

23. ALL EMPTY RACEWAYS AND JUNCTION BOXES SHALL HAVE PULL STRINGS

INSTALLED FOR USE TO INSTALL CABLES BY OTHERS.

TW

SYSTEM GROUND, SIZE IN ACCORDANCE WITH NEC ARTICLE 250

GROUND ROD, "TW" INDICATES TEST WELL

LIGHTNING PROTECTION ROOF CONDUCTORS. SEE DRAWINGS FOR

SIZE.

AIR TERMINAL; NUMBER DENOTES LENGTH OF AIR TERMINAL.

LIGHTNING PROTECTION COUNTERPOISE CONDUCTORS. SEE

DRAWINGS FOR SIZE.

LIGHTNING PROTECTION & GROUNDING SYSTEMS LEGEND

LIGHTNING PROTECTION DOWN CONDUCTORS. SEE DRAWINGS

FOR SIZE.

DOWN-CONDUCTOR IN CONDUIT CONCEALED IN EXTERIOR WALL.

12"

A AMPERES

ACS ACCESS CONTROL SYSTEM

AFF ABOVE FINISHED FLOOR

C CONDUIT

CATV CABLE TELEVISION

CB CIRCUIT BREAKER

CCTV CLOSED CIRCUIT TELEVISION

CF/CI CONTRACTOR FURNISHED, CONTRACTOR INSTALLED

CKT CIRCUIT

COR CONTRACTING OFFICER'S REPRESENTATIVE

CU COPPER

DMS DOOR MONITORING SYSTEM

DVI DIGITAL VIDEO INPUT

EF EXHAUST FAN

ELU EMERGENCY LIGHT UNIT

ESS ELECTRONIC SECURITY SYSTEM

EWC ELECTRIC WATER COOLER

FACP FIRE ALARM CONTROL PANEL

G, GND GROUND

GF/CI GOVERNMENT FURNISHED, CONTRACTOR INSTALLED

GF/GI GOVERNMENT FURNISHED, GOVERNMENT INSTALLED

GFCI GROUND FAULT CIRCUIT INTERRUPTER

HACR HEATING AND AIR CONDITIONING REFRIGERATION

HP HORSEPOWER

HZ HERTZ

IDS INTRUSION DETECTION SYSTEM

IMC INTERMEDIATE METAL CONDUIT

KWH KILOWATT HOUR

LED LIGHT EMITTING DIODE

LT LIGHT

LVS LOW VOLTAGE SWITCH

MCB MAIN CIRCUIT BREAKER

MCCB MOLDED CASE CIRCUIT BREAKER

MFR MANUFACTURER

MH MOUNTING HEIGHT

MLO MAIN LUGS ONLY

MNS MASS NOTIFICATION SYSTEM

MTD MOUNTED

N.E.C. NATIONAL ELECTRICAL CODE

NEC NETWORK ENTERPRISE CENTER

NF NON-FUSED

NO., # NUMBER

NTS NOT TO SCALE

OS OCCUPANCY SENSOR

PH PHASE

PIR PASSIVE INFRARED

R/W RACEWAY

SER SERVICE ENTRANCE RATED

SPD SURGE PROTECTIVE DEVICE

SSMR STANDING-SEAM METAL ROOF

TR TELECOMMUNICATIONS ROOM

TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR

TYP TYPICAL

UL UNDERWRITERS LABORATORY

UOI UNLESS OTHERWISE INDICATED

UON UNLESS OTHERWISE NOTED

V VOLT

VA VOLT-AMPERE

WP WEATHERPROOF

WWB WELDED-WIRE BASKET CABLE TRAY

XFMR TRANSFORMER

ABBREVIATIONS

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

FY20PN55516_BKS_LIGHT,POWER_R18_detached.rvt

3/18/2021 1:49:13 PM

D

EC

EM

BE

R

W

2H N

-2 1-

B-

S.

A

AR

O

N

S.

A

AR

O

N

S.

B

AR

BI

N A

1-

-0

E-001

EL

EC

TR

IC

AL

L

EG

EN

D

G

EN

ER

AL

N O

TE

S

SA

VA

N N

AH

D

IS

TR

IC

T

W . O

G

LE

TH

O

R

PE

A

VE

SA

VA

N

N

AH

, G A

FO

R

T G

O R

D O

N , G

EO

R

G

IA

AI

T

BA

R

R

AC

KS

C

O M

PL

EX

, P H

FY

, P

N

VO

LU

M E

-B

AR

R

AC

KS

(P

LU

M

BI

N G

, M

EC

H

AN

IC

AL

, E

LE

C

TR

IC

AL

A N

D

TE

LE

C

O M

M U

N

IC

AT

IO

N

R . D

AV

IS

READY TO ADVERTISE (RTA)

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

M

AR

2 1

NOTES, TELECOMMUNICATIONS:

1. ALL TELECOMMUNICATIONS WORK SHALL MEET THE REQUIREMENTS OF UFC 3-580-01 FOR "INTERIOR", I3A CRITERIA FOR

"EXTERIOR", AND ANSI/TIA STANDARDS.

2. ALL 8P8C (RJ45 TYPE) CONNECTORS SHALL HAVE A DEDICATED UTP, 4-PAIR, #24 AWG COPPER CABLE, RATED CATEGORY 6 PER

ANSI/TIA 568-D.2 STANDARD.

3. ALL CATEGORY 6 CABLING INSTALLED UNDERGROUND, IN OR UNDER THE FIRST FLOOR SLAB, OR IN WET LOCATIONS SHALL BE

RATED FOR WET LOCATIONS.

4. FOR CATEGORY 6 CABLING, A MINIMUM OF 10 FEET OF CABLE SLACK SHALL BE PROVIDED AT THE TELECOMMUNICATIONS ROOM AND A MINIMUM OF 3 FEET OF CABLE SLACK SHALL BE PROVIDED ABOVE THE SUSPENDED CEILING FOR THE TELECOMMUNICATIONS OUTLET. THE REQUIRED CABLE SLACK LENGTHS ARE IN ADDITION TO THE TOTAL CABLE LENGTHS

REQUIRED TO REACH THE TELECOMMUNICATIONS OUTLETS.

5. BACK-TO-BACK OUTLET BOXES SHALL BE SPACED NOT LESS THAN 16" ON CENTER.

6. ALL CONDUIT TO TELECOMMUNICATIONS OUTLET BOXES (INCLUDING FLOOR BOXES) SHALL BE A MINIMUM OF 1" EMT UNLESS OTHERWISE INDICATED. CONDUITS SHALL BE CONCEALED IN CEILINGS AND WALLS, EXCEPT AS OTHERWISE INDICATED.

7. PULL BOXES SHALL BE PLACED IN CONDUIT RUNS WHERE A CONTINUOUS CONDUIT LENGTH EXCEEDS 100 FEET, OR WHERE THERE ARE MORE THAN TWO 90 DEGREE BENDS. PULL BOXES SHALL BE PLACED IN STRAIGHT, ALIGNED RUNS OF CONDUIT AND

NOT BE USED IN LIEU OF A BEND. PULLBOXES SHALL BE DIRECTLY ACCESSIBLE.

8. ALL TELECOMMUNICATIONS CABLE TRAY, CONDUITS, AND WIRING SHALL BE INSTALLED AND ROUTED IAW UFC 3-580-01, NEMA VE 2, NFPA 70, AND TIA STANDARDS. THESE CABLE TRAYS SHALL NOT BE USED TO RUN CABLING FOR CATV, FIRE ALARM/MASS NOTIFICATION, ETC. CABLE TRAYS SHALL ALSO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS.

9. RACEWAYS/CABLE TRAYS CROSSING STRUCTURAL EXPANSION JOINTS OR SEISMIC JOINTS SHALL BE PROVIDED WITH PROPER EXPANSION FITTINGS TO COMPENSATE FOR THE BUILDING EXPANSION AND CONTRACTION AND TO PROVIDE FOR CONTINUITY OF

GROUNDING.

10. PROVIDE PIPE SLEEVES FOR POWER AND COMMUNICATIONS ENTRANCE AND EXIT CONDUITS THROUGH SLABS AT THE TIME OF THE CONSTRUCTION OF THE SLAB. NO DRILLING OR PUNCHING THROUGH SLABS WILL BE ALLOWED.

11. SEAL PENETRATIONS THROUGH FLOORS AND FIRE WALLS TO MAINTAIN THE INTEGRITY OF THE FIRE AND ACOUSTIC RATINGS

OF THE WALLS AND FLOORS.

12. A MINIMUM OF 36 INCHES OF SPACE SHALL BE PROVIDED BOTH IN FRONT OF AND BEHIND THE RACK AND BEHIND ANY INSTALLED EQUIPMENT. PROVIDE 100 PERCENT SPARE RACK CAPACITY BASED ON THE AMOUNT OF RACK CAPACITY UTILIZED BY

THE PATCH PANELS PROVIDED.

13. INSTALL PLYWOOD BACKBOARDS WITH THE "A" SIDE FACING OUT. PLYWOOD BACKBOARDS SHALL NOT BE PAINTED.

BACKBOARDS SHALL BE SIGNED BY NEC QA/QC PRIOR TO INSTALLATION.

14. CAT6 OUTLETS SHALL UTILIZE TIA-568A PIN CONFIGURATION.

CABLE

GAUGE

CABLE SIZE

CABLE NUMBER

CABLE COUNT

100 PR 24 AWG

CA01 301-400

DOUBLE GANG

JACKS SHALL BE ARRANGED AND LABELED ACCORDING TO THEIR LOCATIONS IN A ROOM. THEY

SHALL BE ARRANGED CLOCKWISE IN ASCENDING ORDER AROUND THE ROOM WHILE STANDING

IN THE DOORWAY LOOKING INTO THE ROOM. FLOOR JACK NUMBER ARRANGEMENT SHOULD

WORK IN CLOCKWISE ORDER LOOKING OUT THE TR DOORWAY. THIS LABELING SCHEME

ADHERES TO THE REQUIRMENTS OUTLINED IN THE ANSI/TIA 606-C TELECOMMUNICATION

STANDARD.

TELECOMMUNICATIONS LABELING SCHEME

TELEPHONE OUTLET WITH MOUNTING PINS AND (1) CAT 6, 8P8C CONNECTOR.

MH = 60" UOI. SUBSCRIPT DENOTES THE FOLLOWING:

"IDS" - PROVIDE CONNECTION FOR IDS CONTROL PANEL.

"WP" - INDICATES A WEATHERPROOF WHILE-IN-USE COVER.

NIPR OUTLET WITH (4) NIPR CAT 6, 8P8C CONNECTORS. MH = 18" UOI.

NIPR OUTLET WITH (2) NIPR CAT 6, 8P8C CONNECTORS AND (2) BLANK POSITIONS.

MH = 18" UOI.

PROVIDE (1) CATEGORY 6, 8P8C (RJ45 TYPE) CONNECTOR. MH = 18" UOI. SUBSCRIPT

DENOTES THE FOLLOWING:

"2" - PROVIDE (2) CAT 6, 8P8C (RJ45 TYPE) CONNECTORS AND (2) BLANK POSITIONS

PROVIDE 4-PAIR CAT 6 CABLE IN 1-INCH CONDUIT FROM TELECOMMUNICATIONS ROOM TO

UMCS PANEL. ADDITIONALLY, PROVIDE 4-PAIR CAT 6 CABLE IN 1" CONDUIT FROM EACH

METER (ELEC, GAS, WATER) TO THE UMCS PANEL.

RECESSED 8-GANG POWER AND COMMUNICATIONS FLOOR BOX. PROVIDE (4) NIPR, (4)

ACN, AND (4) ULLS-A CAT 6, 8P8C CONNECTORS (AND 1 EMPTY GANG) IN THE

COMMUNICATIONS COMPARTMENT OF EACH FLOOR BOX. SEE E-001 FOR POWER

REQUIREMENTS.

RECESSED 4-GANG POWER AND NIPR COMMUNICATIONS FLOOR BOX. PROVIDE (4) DATA

CAT 6, 8P8C CONNECTORS (AND 1 EMPTY GANG) IN THE COMMUNICATIONS

COMPARTMENT OF EACH FLOOR BOX. SEE E-001 FOR POWER REQUIREMENTS.

CATV OUTLET CONSISTING OF ONE "F" CONNECTOR OUTLET. MH = 60" UOI.

3/4" A-C, VOID-FREE, FIRE-RETARDANT PLYWOOD BACKBOARD WITH NO ADDED UREA

FORMALDEHYDE. SEE SPECIFICATION 01 33 29 FOR FOREST STEWARDSHIP COUNCIL

(FSC) CERTIFICATION REQUIREMENTS. PLYWOOD SHALL BE SIGNED BY NEC QA/QC TO

ENSURE COMPLIANCE PRIOR TO INSTALLATION.

7-FT, 19-INCH ALUMINUM RACK WITH VERTICAL WIRE MANAGEMENT ASSEMBLY.

CABLE TRAY. TR'S SHALL HAVE CABLE RUNWAY. BASKET TYPE SHALL BE PROVIDED

ELSEWHERE UOI.

SIPRNET PROTECTIVE DISTRIBUTION (PDS) SYSTEM. MH = 8'-6" UOI.

4-INCH THROUGH WALL CONDUIT.

THROUGH FLOOR STUB UP OR CONDUIT SLEEVE.

PRIMARY BONDING BUSBAR, MH 18" AFF.

SECONDARY BONDING BUSBAR, MH 18" AFF.

JUNCTION BOX, WALL MOUNTED, MH 18" AFF UOI.

JUNCTION BOX, CEILING MOUNTED.

TELECOMMUNICATIONS LEGEND GENERAL NOTES

J

SBB

TR1-R1-PP1

TR1-R1-PP1

TERMINATION

LOCATIONS

TR1 - TR2

TV

J

PORT #

PATCH PANEL #

RACK #

TR ROOM #

PP1

OUTLET ROOM #

PORT #

RM 101

SPECIAL CIRCUITS (I.E.- IDS, ETC.) SHALL BE TERMINATED

ON THE 110 BLOCKS IN THE MAIN NIPR TR.

IDS

PATCH PANEL #

PATCH PANELS LABELING SCHEME

TR1-RR1-PP1

PATCH PANEL #

RACK #

TR ROOM #CABLE

GAUGE

CABLE SIZE

CABLE NUMBER

CABLE COUNT

12 FIBER SM

FC01 1-12

TERMINATION

LOCATIONS

TR1 - TR2

MMAC-1-X

PORT

CARD #

DEVICE

TR1-PP1-X

JACK #

PATCH PANEL #

TR ROOM #

CABLES SHALL BE LABELED WITHIN 12 INCHES OF THE END OF THE CABLE AND CABLE

IDENTIFIERS SHALL APPEAR TWO (2) TIMES ON THE LABEL FOR INCREASED VISIBILITY.

NOTES, TELECOMMUNICATIONS LABELING SCHEME:

1. LABEL MEDIA SHALL BE PRESSURE SENSITIVE AND CONSIST OF TWO PARTS: A LABEL FACE AND CLEAR ADHESIVE MATERIAL. EACH LABEL MUST CONTAIN A WHITE PRINTABLE AREA AND A CLEAR SELF-LAMINATING AREA THAT WILL WRAP AROUND THE CABLE AND LAMINATE THE WHITE

PRINTABLE AREA. EACH LABEL MUST BE MACHINE PRINTED AND HAVE BLACK PRINT OF THE

WHITE LABEL MATERIAL.

BACKBONE CABLES

LABELING SCHEME

PATCH CABLES LABELING

SCHEME

HORIZONTAL CABLES LABELING

SCHEME

OUTLETS LABELING SCHEME

JACKS SHALL BE COLOR CODED TO

MATCH THE CLASSIFICATION OF THE

NETWORK:

UMCS

AFF ABOVE FINISHED FLOOR

BBC BACKBONE BONDING CONDUCTOR

C CONDUIT

CAT CATEGORY

CATV CABLE TELEVISION

CKT CIRCUIT

CFCI CONTRACTOR-FURNISHED, CONTRACTOR-INSTALLED

COR CONTRACTING OFFICER'S REPRESENTATIVE

CU COPPER

FOC FIBER OPTIC CABLE

GFCI GOVERNMENT-FURNISHED, GOVERNMENT-INSTALLED

GFCI GROUND FAULT CIRCUIT INTERRUPTER

GFGI GOVERNMENT-FURNISHED, GOVERNMENT-INSTALLED

G GROUND

IAW IN ACCORDANCE WITH

MH MOUNTING HEIGHT

MTD MOUNTED

NEC NFPA 70, NATIONAL ELECTRICAL CODE, 2017

NIPR NON-SECURE INTERNET PROTOCOL ROUTER

NTS NOT TO SCALE

PBB PRIMARY BONDING BUSBAR

PP PATCH PANEL

SBB SECONDARY BONDING BUSBAR

SBC SECONDARY BONDING CONDUCTOR

SIPR SECURE INTERNET PROTOCOL ROUTER

SPD SURGE PROTECTIVE DEVICE

TBB TELECOMMUNICATIONS BONDING BACKBONE

TMGB TELECOMMUNICATIONS MAIN GROUND BAR

TGB TELECOMMUNICATIONS GROUND BAR

TR TELECOMMUNICATIONS ROOM

TYP TYPICAL

ULLS-A UNIT LEVEL LOGISTICS SYSTEM - AVIATION

UOI UNLESS OTHERWISE INDICATED

UON UNLESS OTHERWISE NOTED

VOIP VOICE OVER INTERNET PROTOCOL

W, WP WEATHERPROOF

ABBREVIATIONS

PBB

AUDIO VISUAL (AV) SYSTEM LEGEND

CEILING-MOUNTED HDMI OUTLET AND VGA OUTLET. PROVIDE EACH IN DEDICATED

1-1/4" CONDUIT WITH PULL STRINGS TO CORRESPONDING AV WALL OUTLETS.

WALL-MOUNTED HDMI OUTLET AND VGA OUTLET. PROVIDE EACH IN DEDICATED

CONDUIT WITH PULL STRINGS TO CORRESPONDING AV CEILIING. MH = 48" AFF UOI.

WALL MOUNTED 24"(H) X 24"(W) X 24"(D) AUDIO VISUAL (AV) ENCLOSURE. MH = 48"

SPECIAL SYSYEMS (SECURITY) SYSTEM LEGEND

DPS

DA

KP

MS

BMS

GFGI WALL MOUNTED SECURITY CAMERAS, FIXED MOUNTED.

GFGI CEILING MOUNTED SECURITY CAMERAS, FIXED MOUNTED.

UL 634 LEVEL 2 HIGH SECURITY SENSOR. PROVIDED WITH DOOR HARDWARE. PROVIDE

INFRASTRUCTURE AS INDICATED ON T-504 AND T-603.

GFGI CARD READER. PROVIDE INFRASTRUCTURE AS INDICATED ON T-603.

GFGI ACCESS CONTROL CABINET. POWER AND DATA CIRCUITS FOR CABINETS SHALL BE

CFCI.

GFGI BALANCED MAGNETIC SWITCH

GFGI KEY PAD.

GFGI PASSIVE INFRARED MOTION SENSOR

GFGI DURESS ALARM.

GFGI IDS CONTROL PANEL. PROVIDE CONDUIT TO JUNCTION BOX AT EACH IDS PANEL

DEVICE LOCATION. POWER AND DATA CIRCUIT FOR PANEL SHALL BE CFCI.

CR

ACS

IDS

AV

AV

AV

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

P:\Revit Projects\Gor0402 (PN55516)\Barracks\_Telework Working\07_Amendment 0002 Revit Files\FY20PN55516_BKS_TELCOMM_R18_TW Current.rvt3/18/2021 2:00:10 PM

D

EC

EM

BE

R

W

2H N

-2 1-

B-

J.

T

EL

LE

Z

J.

T

EL

LE

Z

S.

B

AR

BI

N A

1-

-0

T-001

TE

LE

C O

M M

U N

IC

AT

IO

N

S

LE

G

EN

D A

N D

G

EN

ER

AL

N O

TE

S

SA

VA

N N

AH

D

IS

TR

IC

T

W . O

G

LE

TH

O

R

PE

A

VE

SA

VA

N

N

AH

, G A

FO

R

T G

O R

D O

N , G

EO

R

G

IA

AI

T

BA

R

R

AC

KS

C

O M

PL

EX

, P H

FY

, P

N

VO

LU

M E

-B

AR

R

AC

KS

(P

LU

M

BI

N G

, M

EC

H

AN

IC

AL

, E

LE

C

TR

IC

AL

A N

D

TE

LE

C

O M

M U

N

IC

AT

IO

N

R . D

AV

IS

READY TO ADVERTISE (RTA)

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

M

AR

2 1

BUILDING ACCESS CONTROL SYSTEM RISER DIAGRAM NOTES:

1. THE CONTRACTOR SHALL PROVIDE THE INFRASTRUCTURE FOR A GFGI BUILDING ACCESS CONTROL SYSTEM. CONTRACTOR SHALL ALSO FURNISH AND INSTALL UL 634 LEVEL 2 HIGH SECURITY SENSORS, ELECTRIC POWER TRANSFER (EPT), AND OTHER DEVICES INDICATED ON T-504. COORDINATE BUILDING ACCESS CONTROL SYSTEM WITH ARCHITECTURAL DRAWINGS AND DOOR HARDWARE

SPEC 08 71 00.

2. SLEEPING ROOM ACCESS CONTROL SHALL BE A CFCI SYSTEM AND SHALL BE A STANDALONE SYSTEM FOR EACH SLEEPING ROOM

DOOR AS INDICATED IN DOOR HARDWARE SPEC 08 71 00.

DOOR CONTROLLER

BUILDING ACCESS CONTROL SYSTEM

ENCLOSURE

ROOM 1108A

RS-485

DATA NETWORK

DOOR 1

DOOR 2

DOOR 3

DOOR 4

DOOR 5

DOOR 6

DOOR 7

DOOR 8

POWER SUPPLY

BATTERY

DOOR CONTROLLER

RS-485

DOOR 1

DOOR 2

DOOR 3

DOOR 4

DOOR 5

DOOR 6

DOOR 7

DOOR 8

RS-485

POWER SUPPLY

BATTERY

(1) DPS

DOOR 1000B

(1) DPS

DOOR 1000C

(1) DPS

DOOR 1000O

(1) DPS

DOOR 1000P

CARD READER

ELECTRIC LATCH

(2) DPS

DOOR 1000I

CARD READER

ELECTRIC LATCH

(2) DPS

DOOR 1000A

(2) DPS

DOOR 1000H

DOOR 1000G

(2) DPS

DOOR 1000F

DOOR 201

DOOR 1000M

TO ACS WORKSTATION VIA

DATA OUTLET

DOOR CONTROLLER

BUILDING ACCESS CONTROL SYSTEM

ENCLOSURE

ROOM 1108A

RS-485

DATA NETWORK

DOOR 1

DOOR 2

DOOR 3

DOOR 4

DOOR 5

DOOR 6

DOOR 7

DOOR 8

RS-485

POWER SUPPLY

BATTERY

DOOR CONTROLLER

RS-485

DOOR 1

DOOR 2

DOOR 3

DOOR 4

DOOR 5

DOOR 6

DOOR 7

DOOR 8

RS-485

POWER SUPPLY

BATTERY

TO ACS WORKSTATION VIA

DATA OUTLET

(1) DPS

DOOR 1000J

(2) DPS

(1) DPS

CARD READER

ELECTRIC LATCH

(2) DPS

DOOR 101

DOOR 102

DOOR 103

DOOR 104

(1) DPS

CARD READER

ELECTRIC LATCH

(1) DPS

CARD READER

ELECTRIC LATCH

(1) DPS

(1) DPS

DOOR 202

(1) DPS

DOOR 203

(1) DPS

DOOR 204

(1) DPS

DOOR 301

(1) DPS

DOOR 302

(1) DPS

DOOR 303

(1) DPS

DOOR 304

(1) DPS

DOOR 401

(1) DPS

DOOR 402

(1) DPS

DOOR 403

(1) DPS

DOOR 404

(1) DPS

DOOR 501

(1) DPS

DOOR 502

(1) DPS

DOOR 503

(1) DPS

DOOR 504

(1) DPS

DOOR 1000D

DOOR CONTROLLER

BUILDING ACCESS CONTROL SYSTEM

ENCLOSURE

ROOM 1108A

RS-485

DATA NETWORK

DOOR 1

DOOR 2

DOOR 3

DOOR 4

DOOR 5

DOOR 6

DOOR 7

DOOR 8

RS-485

POWER SUPPLY

BATTERY

DOOR CONTROLLER

RS-485

DOOR 1

DOOR 2

DOOR 3

DOOR 4

DOOR 5

DOOR 6

DOOR 7

DOOR 8

POWER SUPPLY

BATTERY

TO ACS WORKSTATION VIA

DATA OUTLET

(2) DPS

DOOR 1000N

(2) DPS

DOOR 1092

(1) DPS

DOOR 1105

(1) DPS

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

P:\Revit Projects\Gor0402 (PN55516)\Barracks\_Telework Working\07_Amendment 0002 Revit Files\FY20PN55516_BKS_TELCOMM_R18_TW Current.rvt3/18/2021 1:58:55 PM

D

EC

EM

BE

R

W

2H N

-2 1-

B-

J.

T

EL

LE

Z

J.

T

EL

LE

Z

S.

B

AR

BI

N A

1-

-0

T-603

C O

M M

R

IS

ER

D

IA

G

R

AM

S -B

U

IL

D

IN

G A

C C

ES

S

C O

N

TR

O L

SY

ST

EM

SA

VA

N N

AH

D

IS

TR

IC

T

W . O

G

LE

TH

O

R

PE

A

VE

SA

VA

N

N

AH

, G A

FO

R

T G

O R

D O

N , G

EO

R

G

IA

AI

T

BA

R

R

AC

KS

C

O M

PL

EX

, P H

FY

, P

N

VO

LU

M E

-B

AR

R

AC

KS

(P

LU

M

BI

N G

, M

EC

H

AN

IC

AL

, E

LE

C

TR

IC

AL

A N

D

TE

LE

C

O M

M U

N

IC

AT

IO

N

R . D

AV

IS

READY TO ADVERTISE (RTA)

BUILDING ACCESS CONTROL SYSTEM RISER DIAGRAM1

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

M

AR

2 1

EXISTING

PH-GLP-2

EXISTING

PH-GLP-1

EXISTING

PH-GLP-6

EXISTING

PH-GLP-5

EXISTING

PH-GLP-4

EXISTING

PH-GLP-3

EXISTING

PH-ET-4

EXISTING

PH-ET-6

EXISTING

PH-ET-1

EXISTING

PH-ET-2

EXISTING

PH-ET-3

EXISTING

PH-ET-5

EXISTING

PH-BT-1

EXISTING

PH-AS-2

EXISTING

PH-AS-1

EXISTING

PH-AS-6

EXISTING

PH-AS-5

EXISTING

PH-AS-4

EXISTING

PH-AS-3

EXIST. 6" GSS

EXIST. 6" GSR

EXIST. 6" GSS

EXIST. 6" GSR

EXISTING

6" GSS&R TO

WELL FIELD 1

EXISTING

6" GSS&R TO

WELL FIELD 2

EXISTING

6" GSS&R TO

WELL FIELD 6

EXISTING 6"

GSS&R TO

WELL FIELD 5

EXISTING

8" GSS&R TO

WELL FIELD 4

EXISTING

6" GSS&R TO

WELL FIELD 3

EXISTING

8" GSS&R TO

PH. 2 B/COF.

SHUT OFF

VALVES

(TYP)

EXISTING DDC PANELS

EXISTING

CHEMICAL

FEED TANK

2 1/2" GSS&R

TO PHASE 3

BN HQ. SEE

MS101 FOR

CONT.

8" GSS&R TO PHASE 3

B/COF. SEE MS101

FOR CONTINUATION

CTP-1

NEW 6" GSS

NEW 6" GSR

EXIST. 6" GSS

EXIST. 6" GSR

EXIST. 6" GSS

EXIST. 6" GSR

EXIST. 8" GSS

EXIST. 8" GSR

EXIST. 6" GSS

EXIST. 6" GSR

NEW 6" GSS&R TO

NEW COOLING

TOWER. SEE MS101

FOR CONTINUATION

CONNECT NEW 6"

GSS&R PIPING TO

EXISTING VALVES

NEW DDC PANEL

NEW CHEMICAL TREATMENT

FEED SYSTEM (CTFS-1)

TO CT-1

CHEMICAL TREATMENT

LINES TO CLOSED

CIRCUIT COOLER

WATER BASIN, SEE

MP401X FOR CONT.

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENXSWW\Desktop\Tele-Work Revit Projects\Gor0402 (PN55516) BKS\FY20_PN55516_BKS PUMPHOUSE_MECH_R18_TW Current.rvt3/11/2021 9:08:30 AM

D

EC

EM

BE

R

W

2H N

-2 1-

B-

S.

W

YL

LI

E

S.

W

YL

LI

E

S.

B

AR

BI

N A

1-

-0

MP101X

PU

M

P H

O U

SE

H

YD

R

O N

IC

P

IP

IN

G P

LA

N

SA

VA

N N

AH

D

IS

TR

IC

T

W . O

G

LE

TH

O

R

PE

A

VE

SA

VA

N

N

AH

, G A

FO

R

T G

O R

D O

N , G

EO

R

G

IA

AI

T

BA

R

R

AC

KS

C

O M

PL

EX

, P H

FY

, P

N

VO

LU

M E

-B

AR

R

AC

KS

(P

LU

M

BI

N G

, M

EC

H

AN

IC

AL

EL

EC

TR

IC

AL

A N

D T

EL

EC

O M

M U

N

IC

AT

IO

N

K.

D

IX

O

N

READY TO ADVERTISE (RTA)

PUMP HOUSE PIPING PLAN1

PLAN NORTH

164 8268

SCALE: 1/8"=1'-0"

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

M

AR

P-001 PLUMBING LEGEND
E-001 ELECTRICAL LEGEND & GENERAL NOTES
T-001 TELECOMMUNICATIONS LEGEND AND GENERAL NOTES
T-603 COMM RISER DIAGRAMS - BUILDING ACCESS CONTROL SYSTEM
MP101X PUMP HOUSE HYDRONIC PIPING PLAN