W912HN-20-R-3009_VOL2.pdf
PDF 32 MB Posted
- Solicitation number
- W912HN20R3009
About this file
This document provides details for a federal contract solicitation to construct an aircraft maintenance hangar at Hunter Army Airfield in Savannah, Georgia. The solicitation was posted on October 29, 2020 under number W912HN20R3009 by the Department of the Army Corps of Engineers Engineering District Savannah. Proposals are due no later than December 15, 2020 at 1:00pm Eastern Time. The solicitation package includes three drawings files and five specifications files. Updated files will replace prior versions bearing the same file name. Bidders must review all accessible blue links to obtain the full amended solicitation.
View the file
Other files
Show all 43
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
7/27/20
FUNK.TROY.ALAN.1039
429256
Digitally signed by
FUNK.TROY.ALAN.1039429256
Date: 2020.07.28 14:59:01 -04'00'
HENDREN.TRACY.LEE.1229932868
2020.07.29 08:13:06 -04'00'
A N
S I
D
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
J
M C
T
IE
R N
A N
R
H A
L L
M A
N
H U
N T
E R A
R M
Y A
IR
F
IE
L D
G E
O R
G
IA
F Y P
N
V O
L U
M E B
U
IL
D
IN
G S
T R
U C
T U
R A
L
A R
C H
IT
E C
T U
R E
SHEET ID
F
IL
E N
A M
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
®of Engineers
US Army Corps k6enxjlh
04-SEP-2020 09:14
C:\Users\k6enxjlh\Desktop\Projects\ProjectWise_Projects\Hun0400\05_W912HN-20-B-3009\PDF\Volume 2\hzpgi001v2ix.dgn
C A
T E
G O
R Y C
O D
E
-1
-0
GI001
IN
D
E X O
F D
R A
W
IN
G S h z p g i0 v ix .d g n
IN
T
E R
IO
R D
E S
IG
N A
N D F
IR
E P
R O
T E
C T
IO
N
J U
L Y
A A
B A
IR
C R
A F
T M
A
IN
T E
N A
N C
E H
A N
G A
R
READY TO ADVERTISE (RTA)
W
H N -2
-R -3
J
H A
IR
E
J
H A
IR
E
SHEET ID.
INDEX OF DRAWINGS
D
S C
R
IP
T
IO
N
W
O G
L E
T H
O R
P E A
V E
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
S A
V A
N N
A H D
IS
T R
IC
T
S A
V A
N N
A H
G A
SHEET ID.
TITLESHEET ID.
TITLETITLE
G-001 COVER SHEET
GI001 INDEX OF DRAWINGS
GI002 GENERAL NOTES, ABBREVIATIONS
S-001 GENERAL STRUCTURAL NOTES
S-002 GENERAL STRUCTURAL NOTES
S-003 GENERAL STRUCTURAL NOTES
SB101 FOUNDATION COMPOSITE PLAN
SB102 FOUNDATION PLAN - AREA A
SB103 FOUNDATION PLAN - AREA B
SB104 FOUNDATION PLAN - AREA C
SB105 FOUNDATION PLAN - AREA D
SB106 FOUNDATION PLAN - AREA E
SB107 FOUNDATION PLAN - AREA F
SB108 SLAB COMPOSITE PLAN
SB109 SLAB PLAN - AREA A
SB110 SLAB PLAN - AREA B
SB111 SLAB PLAN - AREA C
SB112 SLAB PLAN - AREA D
SB113 SLAB PLAN - AREA E
SB114 SLAB PLAN - AREA F
SB301 FOUNDATION SECTIONS
SB302 FOUNDATION SECTIONS
SB303 FOUNDATION SECTIONS
SB501 FOUNDATION DETAILS
SB502 FOUNDATION & SLAB DETAILS
SB503 SLAB DETAILS
SB504 FOUNDATION AND SLAB DETAILS
SB505 BASE PLATE DETAILS AND SCHEDULE
SB510 MASONRY DETAILS
SB511 MASONRY DETAILS
SB512 MISC DETAILS AND SECTIONS
SB601 FOUNDATION SCHEDULES
SF101 SECOND FLOOR/LOW ROOF FRAMING COMPOSITE PLAN
SF102 2ND FLOOR/LOW ROOF FRAMING PLAN - AREA A
SF103 2ND FLOOR/LOW ROOF FRAMING PLAN - AREA B
SF104 2ND FLOOR/LOW ROOF FRAMING PLAN - AREA C
SF105 2ND FLOOR/LOW ROOF FRAMING PLAN - AREA D
SF106 2ND FLOOR/LOW ROOF FRAMING PLAN - AREA E
SF107 2ND FLOOR/LOW ROOF FRAMING PLAN - AREA F
SF108 DOOR SUPPORT FRAMING COMPOSITE PLAN
SF109 DOOR SUPPORT FRAMING & RUNWAY BEAM PLAN - AREA A
SF110 DOOR SUPPORT FRAMING & RUNWAY BEAM PLAN - AREA B
SF111 DOOR SUPPORT FRAMING & RUNWAY BEAM PLAN - AREA C
SF112 TRUSS BOTTOM CHORD FRAMING COMPOSITE PLAN
SF113 TRUSS BOTTOM CHORD FRAMING PLAN - AREA A
SF114 TRUSS BOTTOM CHORD FRAMING PLAN - AREA B
SF115 TRUSS BOTTOM CHORD FRAMING PLAN - AREA C
SF116 PLATFORM FRAMING COMPOSITE PLAN
SF117 HIGH ROOF FRAMING COMPOSITE PLAN
SF118 HIGH ROOF FRAMING PLAN - AREA A
SF119 HIGH ROOF FRAMING PLAN - AREA B
SF120 HIGH ROOF FRAMING PLAN - AREA C
SF121 HIGH ROOF FRAMING PLAN - AREA D
SF122 HIGH ROOF FRAMING PLAN - AREA E
SF123 HIGH ROOF FRAMING PLAN - AREA F
SF201 FRAMING ELEVATIONS
SF202 FRAMING ELEVATIONS
SF203 FRAMING ELEVATIONS
SF204 FRAMING ELEVATIONS
SF205 FRAMING ELEVATIONS
SF206 FRAMING ELEVATIONS
SF207 FRAMING ELEVATIONS
SF301 FRAMING SECTIONS
SF302 FRAMING SECTIONS
SF303 FRAMING SECTIONS
SF304 FRAMING SECTIONS
SF305 FRAMING SECTIONS
SF311 TRUSS ELEVATIONS
SF312 TRUSS ELEVATIONS
SF313 SWAY BRACING
SF401 ENLARGED PLANS
SF402 ENLARGED PLANS
SF403 ENLARGED PLANS
SF404 ENLARGED PLANS
SF405 ENLARGED PLANS
SF406 ENLARGED PLANS
SF501 FRAMING DETAILS
SF502 FRAMING DETAILS
SF503 FRAMING DETAILS
SF504 FRAMING DETAILS
SF505 FRAMING DETAILS
SF506 FRAMING DETAILS
SF510 BRACING DETAILS
SF511 ROOF FRAMING DETAILS
SF512 TRUSS DETAILS
SF513 TRUSS DETAILS
A-001 ARCHITECTURAL LEGEND & GENERAL NOTES
A-002 LIFE SAFETY CRITERIA
A-003 COMPOSITE FIRST FLOOR EGRESS PLAN
A-004 COMPOSITE SECOND FLOOR EGRESS PLAN
A-005 FIRST FLOOR EGRESS PLAN - AREA A
A-006 FIRST FLOOR EGRESS PLAN - AREA B
A-007 FIRST FLOOR EGRESS PLAN - AREA C
A-008 FIRST FLOOR EGRESS PLAN - AREA D
A-009 FIRST FLOOR EGRESS PLAN - AREA E
A-010 FIRST FLOOR EGRESS PLAN - AREA F
A-011 SECOND FLOOR EGRESS PLAN - AREA A
A-012 SECOND FLOOR EGRESS PLAN - AREA B
A-013 SECOND FLOOR EGRESS PLAN - AREA C
A-014 SECOND FLOOR EGRESS PLAN - AREA D
A-015 SECOND FLOOR EGRESS PLAN - AREA E
A-016 SECOND FLOOR EGRESS PLAN - AREA F
A-101 FIRST FLOOR COMPOSITE PLAN
A-102 SECOND FLOOR COMPOSITE PLAN
A-103 FIRST FLOOR PLAN - AREA A
A-104 FIRST FLOOR PLAN - AREA B
A-105 FIRST FLOOR PLAN - AREA C
A-106 FIRST FLOOR PLAN - AREA D
A-107 FIRST FLOOR PLAN - AREA E
A-108 FIRST FLOOR PLAN - AREA F
A-109 SECOND FLOOR PLAN - AREA A
A-110 SECOND FLOOR PLAN - AREA B
A-111 SECOND FLOOR PLAN - AREA C
A-112 SECOND FLOOR PLAN - AREA D
A-113 SECOND FLOOR PLAN - AREA E
A-114 SECOND FLOOR PLAN - AREA F
A-115 FIRST FLOOR DIMENSION PLAN - AREA A
A-116 FIRST FLOOR DIMENSION PLAN - AREA B
A-117 FIRST FLOOR DIMENSION PLAN - AREA C
A-118 FIRST FLOOR DIMENSION PLAN - AREA D
A-119 FIRST FLOOR DIMENSION PLAN - AREA E
A-120 FIRST FLOOR DIMENSION PLAN - AREA F
A-121 SECOND FLOOR DIMENSION PLAN - AREA A
A-122 SECOND FLOOR DIMENSION PLAN - AREA B
A-123 SECOND FLOOR DIMENSION PLAN - AREA C
A-124 SECOND FLOOR DIMENSION PLAN - AREA D
A-125 SECOND FLOOR DIMENSION PLAN - AREA E
A-126 SECOND FLOOR DIMENSION PLAN - AREA F
A-127 FIRST FLOOR COMPOSITE REFLECTED CEILING PLAN
A-128 SECOND FLOOR COMPOSITE REFLECTED CEILING PLAN
A-129 FIRST FLOOR REFLECTED CEILING PLAN - AREA A
A-130 FIRST FLOOR REFLECTED CEILING PLAN - AREA B
A-131 FIRST FLOOR REFLECTED CEILING PLAN - AREA C
A-132 FIRST FLOOR REFLECTED CEILING PLAN - AREA D
A-133 FIRST FLOOR REFLECTED CEILING PLAN - AREA E
A-134 FIRST FLOOR REFLECTED CEILING PLAN - AREA F
A-135 SECOND FLOOR REFLECTED CEILING PLAN - AREA A
A-136 SECOND FLOOR REFLECTED CEILING PLAN - AREA B
A-137 SECOND FLOOR REFLECTED CEILING PLAN - AREA C
A-138 SECOND FLOOR REFLECTED CEILING PLAN - AREA D
A-139 SECOND FLOOR REFLECTED CEILING PLAN - AREA E
A-140 SECOND FLOOR REFLECTED CEILING PLAN - AREA F
A-141 COMPOSITE ROOF PLAN
A-201 NORTH ELEVATION
A-202 EAST ELEVATION
A-203 SOUTH ELEVATION
A-204 WEST ELEVATION
A-301 BUILDING CROSS SECTION
A-302 BUILDING LONGITUDINAL SECTION I
A-303 BUILDING LONGITUDINAL SECTION II
A-304 BUILDING SECTIONS I
A-305 BUILDING SECTIONS II
A-310 WALL SECTIONS I
A-311 WALL SECTIONS II
A-312 WALL SECTIONS III
A-313 WALL SECTIONS IV
A-320 WALL DETAILS I
A-321 WALL DETAILS II
A-322 WALL DETAILS III
A-401 ENLARGED STAIR PLANS I
A-402 ENLARGED STAIR PLANS II
A-403 ENLARGED TOILET PLANS I
A-404 ENLARGED TOILET PLANS II
A-405 ENLARGED TOILET PLANS III
A-406 ENLARGED ENTRY PLAN
A-407 ENLARGED HANGAR DOOR PLANS
A-408 ENLARGED HANGAR DOOR REFLECTED CEILING PLAN
A-409 ENLARGED HANGAR DOOR REFLECTED CEILING PLAN
A-410 ENLARGED INTERIOR ELEVATIONS (MEN'S TOILET-SHOWERS)
A-411 ENLARGED INTERIOR ELEVATIONS (WOMEN'S TOILET/SHOWERS)
A-412 ENLARGED INTERIOR ELEVATIONS (MEN'S & WOMEN'S TOILETS)
A-413 ENLARGED INTERIOR ELEVATIONS (BREAK/CONFERENCE ROOMS)
A-414 ENLARGED INTERIOR ELEVATIONS (CONFERENCE & DT/CBT)
A-415 ENLARGED INTERIOR ELEVATIONS
A-416 ENLARGED INTERIOR ELEVATIONS
A-417 ENLARGED INTERIOR ELEVATIONS
A-418 TOILET & ACCESSORIES LEGEND AND MOUNTING HEIGHTS
A-420 INTERIOR STAIR ELEVATIONS I
A-421 INTERIOR STAIR ELEVATIONS II
A-422 ENLARGED CATWALK PLAN - AREA A
A-423 ENLARGED CATWALK PLAN - AREA B
A-424 ENLARGED CATWALK PLANS I
A-425 ENLARGED CATWALK PLANS II
A-426 CATWALK EAST ELEVATION
A-427 CATWALK DETAILS I
A-428 CATWALK DETAILS II
A-429 BIRD NETTING ACCESSORIES
A-430 ENLARGED PLANS - ELEVATOR
A-501 STAIR DETAILS I
A-502 EXTERIOR WALL PENETRATION DETAILS
A-503 INTERIOR WALL PENETRATION DETAILS
A-504 PLAN DETAILS I
A-505 PLAN DETAILS II
A-506 PLAN DETAILS III
A-507 CASEWORK DETAILS
A-510 ROOF DETAILS I
A-511 ROOF DETAILS II
A-512 ROOF DETAILS III
A-520 CEILING DETAILS
A-521 CEILING DETAILS - SEISMIC
A-601 PARTITION TYPES I
A-602 PARTITION TYPES II
A-603 PARTITION TYPES III
A-610 ROOM FINISH SCHEDULE I
A-611 ROOM FINISH SCHEDULE II
A-612 DOOR AND FRAME SCHEDULE I
A-613 DOOR AND FRAME SCHEDULE II
A-614 DOOR DETAILS I
A-615 DOOR DETAILS II
A-616 DOOR DETAILS III
A-617 DOOR DETAILS IV
A-620 WINDOW AND LOUVER SCHEDULE
A-621 WINDOW DETAILS I
A-622 WINDOW DETAILS II
A-901 FIRST FLOOR AIR BARRIER PLAN
A-902 SECOND FLOOR AIR BARRIER PLAN
A-903 AIR BARRIER SECTIONS
A-904 AIR BARRIER DETAILS I
A-905 AIR BARRIER DETAILS II
A-906 AIR BARRIER DETAILS III
A-907 AIR BARRIER DETAILS IV
A-908 AIR BARRIER DETAILS V
I-100 FURNITURE LEGEND
I-101 FIRST FLOOR COMPOSITE FURNITURE PLAN
I-102 FIRST FLOOR FURNITURE PLAN - AREA A
I-103 FIRST FLOOR FURNITURE PLAN - AREA B
I-104 FIRST FLOOR FURNITURE PLAN - AREA C
I-105 FIRST FLOOR FURNITURE PLAN - AREA D
I-106 FIRST FLOOR FURNITURE PLAN - AREA E
I-107 FIRST FLOOR FURNITURE PLAN - AREA F
I-108 SECOND FLOOR COMPOSITE FURNITURE PLAN
I-109 SECOND FLOOR FURNITURE PLAN - AREA D
I-110 SECOND FLOOR FURNITURE PLAN - AREA E
I-111 SECOND FLOOR FURNITURE PLAN - AREA F
I-501 SIGNAGE TYPICALS 1
I-502 SIGNAGE TYPICALS 2
I-503 FINISH LEGEND & DETAILS
I-601 ROOM FINISH SCHEDULE 1
I-602 ROOM FINISH SCHEDULE 2
I-603 SIGNAGE SCHEDULE & DETAILS
FA001 FA & MNS LEGEND AND OPERATIONS MATRIX
FA002 HIGH-EXPANSION FOAM SYSTEM CONTROL PANEL MATRIX
FA100 FA & MNS FLOOR PLAN - 1ST FLOOR - OVERALL
FA101 FA & MNS FLOOR PLAN - 1ST FLOOR - PART A
FA102 FA & MNS FLOOR PLAN - 1ST FLOOR - PART B
FA103 FA & MNS FLOOR PLAN - 1ST FLOOR - PART C
FA104 FA & MNS FLOOR PLAN - 1ST FLOOR - PART D
FA105 FA & MNS FLOOR PLAN - 1ST FLOOR - PART E
FA106 FA & MNS FLOOR PLAN - 1ST FLOOR - PART F
FA107 FA & MNS FLOOR PLAN - 2ND FLOOR - OVERALL
FA108 FA & MNS FLOOR PLAN - 2ND FLOOR - PART D
FA109 FA & MNS FLOOR PLAN - 2ND FLOOR - PART E
FA110 FA & MNS FLOOR PLAN - 2ND FLOOR - PART F
FA501 FIRE ALARM & MASS NOTIFICATION DETAILS
FA502 FIRE ALARM & MASS NOTIFICATION DETAILS
FA601 FIRE ALARM AND MNS DIAGRAM
FA602 FOAM SYSTEM CONTROL PANEL, CONTAINMENT SYSTEM, & DIVERTER VALVE RISER DIAGRAMS
FX001 FIRE PROTECTION LEGEND, PRELIMINARY FLOW TEST DATA, AND APPLICABLE CRITERIA
FX002 HANGAR BUILDING FIRE SUPPRESSION SYSTEM NOTES
FX003 MAINTENANCE BAY FIRE PROTECTION AND WATER SUPPLY CALCULATIONS
FX004 FOAM SYSTEM FLOW RATE AND PRESSURE LOSS AT STEADY STATE
FX100 FIRE PROTECTION FLOOR PLAN - 1ST FLOOR OVERALL
FX101 FIRE PROTECTION FLOOR PLAN - 1ST FLOOR - PART A
FX102 FIRE PROTECTION FLOOR PLAN - 1ST FLOOR - PART B
FX103 FIRE PROTECTION FLOOR PLAN - 1ST FLOOR - PART C
FX104 FIRE PROTECTION FLOOR PLAN - 1ST FLOOR - PART D
FX105 FIRE PROTECTION FLOOR PLAN - 1ST FLOOR - PART E
FX106 FIRE PROTECTION FLOOR PLAN - 1ST FLOOR - PART F
FX107 FIRE PROTECTION FLOOR PLAN - 2ND FLOOR - OVERALL
FX108 FIRE PROTECTION FLOOR PLAN - 2ND FLOOR - PART D
FX109 FIRE PROTECTION FLOOR PLAN - 2ND FLOOR - PART E
FX110 FIRE PROTECTION FLOOR PLAN - 2ND FLOOR - PART F
FX140 FOAM GENERATION PLAN
FX201 MAINTENANCE BAY DRAFT CURTAINS
FX401 ENLARGED FIRE SUPPRESSION ROOM
FX501 FIRE PROTECTIONS DETAILS
FX502 FIRE PROTECTION DETAILS II
FX503 FIRE PROTECTION DETAILS III
FX504 FIRE PROTECTION DETAILS IV
FX505 FIRE WATER STORAGE TANK DETAILS
FX506 FOAM MIXING ROOM AND FOAM PROPORTIONER PROPORTIONER DETAILS (TYPICAL)
FX507 FIRE SUPPRESSION ROOM RISER DETAIL
FX601 MAINTENANCE BAY FOAM SUPPRESSION SYSTEM DIAGRAM
FX602 FIRE WATER SUPPLY DIAGRAM - PUMP HOUSE AND TANK
FX603 FOAM CONCENTRATE PUMP AND TANK DETAIL
FX604 FIRE PROTECTION SCHEDULES
SHEET LOGICMATERIALS
EARTH
DRAWING ABBREVIATIONS GENERAL NOTES
C (cont) ---------------------
CORR CORRIDOR
CP CONCRETE PIPE
CPT CARPET
CR CONTROL ROOM
CS CAST STONE
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTR CENTER
CU FT CUBIC FEET
CW CASEMENT WINDOW
D ---------------------
D DEPTH
D LABEL CLASS D DOOR
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
E ---------------------
E LABEL CLASS E DOOR
EA EACH
EF EACH FACE
EIFS EXTERIOR INSULATION
AND FINISH SYSTEM
EJ EXPANSION JOINT
ES EACH SIDE
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
ENTR ENTRANCE
EPS EXPANDED POLYSTYRENE
EQ EQUAL
EWC ELECTRIC WATER COOLER
EXP EXPOSED, EXPANSION
EXT EXTERIOR, EXTINGUISHER
EXT GR EXTERIOR GRADE
F ---------------------
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR
PANEL
FAS BD FASCIA BOARD
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FED FEDERAL
FF FINISH FLOOR
FFE FINISH FLOOR ELEVATION
FF INSUL FOIL BACKED INSULATION
FGL FIBERGLASS
FH FIRE HOSE
FHP FULL HEIGHT PARTITION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FM FACTORY MUTUAL
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FR FIRE RESISTANT
FRG FIBER REINFORCED GYPSUM
FRMG FRAMING
FRP FIBERGLASS REINFORCED
PLASTIC
FRTW FIRE RETARDANT TREATED
WOOD
FS FEDERAL SPECIFICATION
FSTNR FASTENER
FT FEET
FTG FOOTING
FWC FABRIC WALLCOVERING
G ---------------------
G NATURAL GAS
GALV GALVANIZED
GB GRAB BAR
GEJ GUTTER EXPANSION JOINT
G (cont) ---------------------
GFCI GOVERNMENT FURNISHED
CONTRACTOR INSTALLED
GFGI GOVERNMENT FURNISHED
GOVERNMENT INSTALLED
GFRG GLASS-FIBER-REINFORCED
GYPSUM
GLZ GLAZING
GR FL GROUND FLOOR
GUT GUTTER
GWB GYPSUM WALL BOARD
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
H ---------------------
HB HOSE BIBB
HC HANDICAPPED
HDPE HIGH DENSITY POLYETHYLENE
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE
AIR (FILTER)
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HORIZ HORIZONTAL
HR HOUR
HT HEIGHT
HYDR HYDRAULIC
I ---------------------
IBC INTERNATIONAL BUILDING
CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J ---------------------
JAN JANITOR
JT JOINT
K ---------------------
KPD KEYPAD
KIT KITCHEN
KPL KICKPLATE
L ---------------------
LAM LAMINATE
LAV LAVATORY
LBR LUMBER
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LG LIGHT GAUGE
LIB LIBRARY
LIN LINEAR
LKR LOCKER
LOC LOCATION
LT LIGHT
LVDR LOUVER DOOR
LVR LOUVER
M ---------------------
MACH RM MACHINE ROOM
MATL MATERIAL
MAX MAXIMUM
MC MOISTURE CONTENT
MD METAL DECK
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MEMB MEMBRANE
MF MILL FINISH
MFR MANUFACTURER
MID MIDDLE
MIN MINIMUM, MINUTE
MIRR MIRROR
MISC MISCELLANEOUS
MLDG MOLDING (MOULDING)
MO MASONRY OPENING
MOD MODIFY
MB MOISTURE BARRIER
MTD MOUNTED
MTG MOUNTING
MTL METAL
MVBL MOVABLE
MWP MEMBRANE WATERPROOFING
N ---------------------
N NORTH
NA NOT APPLICABLE
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
N (cont) ---------------------
NOM NOMINAL
NP NO PAINT
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
O -------------------
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OFF OFFICE
OGL OBSCURE GLASS
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPQ OPAQUE
OWSJ OPEN WEB STEEL JOIST
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P --------------------
PA PUBLIC ADDRESS
PAR PARAPET
PAT PATTERN
PB PULL BOX
PBD PARTICLEBOARD
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PH PHASE
PIL PILASTER
PL PROPERTY LINE
PL GL PLATE GLASS
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLG PILING
PLYWD PLYWOOD
PNL PANEL
PP PL PUSH/PULL PLATE
PR PAIR
PRCST PRECAST
PREFIN PREFINISHED
PRKG PARKING
PS CONC PRESTRESSED CONCRETE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTDR PAPER TOWEL DISPENSER
AND RECEPTACLE
PTN PARTITION
PWR POWER
Q --------------------
QT QUARRY TILE
QTY QUANTITY
R --------------------
RB RESILIENT BASE
RBM REINFORCED BRICK MASONRY
RBR RUBBER
RC REINFORCED CONCRETE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RDG INS RIGID INSULATION, SOLID
REC RECESSED
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
REST RESTROOM
RF RESILIENT FLOORING
RFG ROOFING
RH ROOF HATCH
RHR RIGHT HAND REVERSE
RL ROOF LEADER
RLG RAILING
RM ROOM
RO ROUGH OPENING
RSD ROLLING STEEL DOOR
RV ROOF VENT
RVL REVEAL
S --------------------
SB SPLASH BLOCK
SCHED SCHEDULE
SD SMOKE DETECTOR
S (cont) --------------------
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SGL SINGLE
SHT MTL SHEET METAL
FLASH (FLASHING)
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SKLT SKYLIGHT
SLNT SEALANT
SMK SMOKE
SMLS SEAMLESS
SP EL SPOT ELEVATION
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SS STAINLESS STEEL
SSMR STANDING SEAM METAL ROOF
ST STAIRS
STC SOUND TRANSMISSION
COEFFICIENT
STD STANDARD
STL STEEL
STL JST STEEL JOIST
STL RF DK STEEL ROOF DECK
STOR STORAGE
STR STRINGERS
STRB/HRN STROBE/HORN
STRUC STRUCTURAL
SUB FL SUBFLOOR
SUSP SUSPENDED
SV SHEET VINYL
SW SIDEWALK
T --------------------
T TREAD
T/S TUB/SHOWER
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZZO
TFF TOP OF FINISH FLOOR
TH THICK
THK THICKNESS
TK BD TACKBOARD
TMPD GL TEMPERED GLASS
TN TRUE NORTH
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOPO TOPOGRAPHY
TOS TOP OF SLAB
TRANS TRANSOM
TRTD TREATED
TV TELEVISION
TYP TYPICAL
U --------------------
UG UNDERGROUND
UH UNIT HEATER
UL UNDERWRITER
LABORATORIES
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER
SYSTEM
V --------------------
VAV VARIABLE AIR VOLUME/UNIT
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VTR VENT THRU ROOF
W --------------------
W/ WITH
WC WATER CLOSET
WD WOOD
WDW WINDOW
W/O WITHOUT
WWF WELDED WIRE FABRIC
X --------------------
XFMR TRANSFORMER
A ---------------------
A LABEL CLASS A DOOR
A/C AIR CONDITION
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ABV ABOVE
ACC ACCESSIBLE
ACS AUTOMATIC CONTROL SYSTEM
ACS DR ACCESS DOOR
ACS PNL ACCESS PANEL
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH
DIDISABILITIES ACT
ADJ ADJACENT
ADMIN ADMINISTRATION
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGGR AGGREGATE
AHU AIR HANDLING UNIT
AIB AIR INFILTRATION BARRIER
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZE
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT
ASC ABOVE SUSPENDED CEILING
ASSY ASSEMBLY
ATC ACOUSTICAL TILE CEILING
AVG AVERAGE
AWT ACOUSTICAL WALL TREATMENT
B ---------------------
B LABEL CLASS B DOOR
BALC BALCONY
BD BOARD
BDRY BOUNDARY
BEJ BRICK EXPANSION JOINT
BFF BELOW FINISH FLOOR
BHMA BUILDER'S HARDWARE
MANUFACTURER'S
ASSOCIATION
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BN BULLNOSE
BOS BOTTOM OF STEEL
BOT BOTTOM
BRG BEARING
BRKT BRACKET
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOFING
C ---------------------
C LABEL CLASS C DOOR
CAB CABINET
CATW CATWALK
CAV CAVITY
CBB CEMENTITIOUS (BACKER)
BOARD
CD CONSTRUCTION DOCUMENTS
CDW CHILLED DRINKING WATER
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CFCI CONTRACTOR FURNISHED/
CONTRACTOR INSTALLED
CFE CONTRACTOR FURNISHED
EQUIPMENT
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL FRAMING
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CI CAST IRON
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG DIFF CEILING DIFFUSER
CLG HT CEILING HEIGHT
CLL COLUMN LINE
CLO CLOSET
CLR COLOR
CMU CONCRETE MASONRY UNIT
CNDS CONDENSATE
CDR CARD READER
CO CLEANOUT
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONC FLR CONCRETE FLOOR
CONF CONFERENCE
CONT CONTINUE, CONTINUOUS
COORD COORDINATE
0 GRID/COLUMN
LINE DESIGNATOR
INTERIOR ELEVATION
SECTION
ROOM
NAME/NUMBER
REVISION
TAG
PLAN, BLOW-UP
DETAIL
PLAN NORTH
NORTH ARROW
W/ TRUE NORTH
INDICATION
SPOT ELEVATION
Name Elevation REFERENCE LEVEL
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
A-101
SIM
EXTERIOR ELEVATION
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
A-101
SYMBOLS
INTERIOR ELEVATION SYMBOL
EXTERIOR ELEVATION SYMBOL
SECTION SYMBOL
CALLOUT SYMBOL
ELEVATION SYMBOL
LEVEL SYMBOL
GENERAL SYMBOLS
Room name
Room name
150 SF
ROOM
NAME/NUMBER
W/ AREA
CENTERLINE
INDICATOR
1/2 1 21
SCALE: 1"=1'-0"
SCALE BAR
View Name1
MATCHLINE INDICATOR
VIEW TITLE BAR
1 / A-101
1 / A-102
REFERENCE
SHEETS
SAND
CONCRETE/ PRECAST
CONCRETE
STONE
BRICK
CMU
PLYWOOD
RIGID INSULATION
BATT INSULATION
GYPSUM BOARD,
PLASTER
EIFS
1. THESE LEGENDS ARE COMPOSED OF STANDARD SYMBOLS AND ARE PERTINENT TO THE CONDITIONS
ON THIS SET OF DRAWINGS TO THE EXTENT APPLICABLE.
2. ADDITIONAL LEGENDS AND/OR ABBREVIATIONS MAY APPEAR IN THIS SET OF DRAWINGS TO INDICATE
SPECIFIC CONDITIONS IN LIEU OF SYMBOLS SHOWN ON THIS SHEET.
A-101
SIM
A101
Ref
R ef
Ref
R ef
AE201
DISCIPLINE*:
G - GENERAL
C - CIVIL
L - LANDSCAPE
S - STRUCTURAL
A - ARCHITECTURE
DISCIPLINE DESIGNATOR
SHEET TYPE
DESIGNATOR
SHEET SEQUENCE
NUMBER
F- FIRE PROTECTION
P - PLUMBING
M - MECHANICAL
E - ELECTRICAL
T-
TELECOMMUNICATIONS
*ADDITIONAL DISCIPLINES MAY BE USED
IN THIS DRAWING SET.
DRAWING NAMING CONVENTION
SHEET ID
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6enxjlh\Desktop\Projects\Hun0400\05_W912HN-20-B-3009\Revit\FY20PN88410_PROJ_R18_TW Current.rvt24-Jul-20 3:53:38 PM
JU
LY
SO
LI
C
IT
AT
IO
N
N O
W
2H
N -2
0- B-
C O
N
TR
AC
T
N O
J.
H
AI
R
E
J.
H
AI
R
E
R .H
AL
LM
AN
1-
-0
GI002
G
EN
ER
AL
N O
TE
S, A
BB
R
EV
IA
TI
O N
S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
H U
N
TE
R A
R M
Y
AI
R
FI
EL
D
, G
EO
R G
IA
AA
B
AI
R C
R
AF
T M
AI
N
TE
N
AN
C
E H
AN
G
AR
PN
0, P N
VO
LU
M
E 2-
BU
IL
D
IN
G (S
TR
U
C
TU
R
AL
,A R
C H
IT
EC
TU
R
E
IN
TE
R
IO
R
D
ES
IG
N
A N
D F
IR
E
PR
O
TE
C
TI
O
N
J.
M
C
TI
ER
N
AN
READY TO ADVERTISE (RTA)
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
GENERAL NOTES:
1. THIS STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER ALL BUILDING CONSTRUCTION IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND SEQUENCES TO ENSURE SAFETY OF THE BUILDING AND ITS COMPONENTS DURING ERECTION. THIS INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, TEMPORARY BRACING, GUYS, OR TIE-DOWNS.
2. THE CONTRACT DOCUMENTS DO NOT INDICATE THE MEANS AND METHODS OF CONSTRUCTION. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK DURING ERECTION AND CONSTRUCTION AND
SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, PROCEDURES,
TECHNIQUES, SEQUENCES, AND SAFETY.
3. USE STRUCTURAL DRAWINGS IN CONJUNCTION WITH ALL OTHER DRAWINGS AND SPECIFICATIONS.
COORDINATE THE WORK OF OTHER TRADES INCLUDING, BUT NOT LIMITED TO, THE REQUIREMENTS
FOR SLEEVES, INSERTS, HOLES, HANGERS, AND ANCHORS.
4. REPORT DISCREPANCIES IN DIMENSIONS BETWEEN DIFFERENT DRAWINGS TO THE CONTRACTING
OFFICER PRIOR TO BEGINNING WORK IN IMPACTED AREAS.
5. DETAILS TITLED OR NOTED AS "TYPICAL" APPLY NOT ONLY WHERE SPECIFICALLY INDICATED OR
REFERENCED, BUT ALSO IN ALL OTHER CASES WHERE THE NATURE OF THE CONSTRUCTION
REQUIRES THEIR USE. DETERMINE APPLICABILITY OF TYPICAL DETAILS FROM DESCRIPTIVE TITLES OR FROM THE SIMILARITY OF A CONSTRUCTION CONDITION TO ANOTHER CONDITION WHERE THE DETAIL
IS SPECIFICALLY INDICATED OR REFERENCED.
6. ELEVATIONS ON THE STRUCTURAL DRAWINGS ARE DENOTED AS [±X'-X"] REFERENCED TO THE FINISHED FIRST FLOOR ELEVATION DATUM [0'-0"]. SEE CIVIL DRAWINGS FOR ACTUAL DATUM
ELEVATION.
7. WHERE A DETAIL OR SECTION IS SHOWN FOR ONE CONDITION, IT SHALL APPLY TO ALL LIKE OR
SIMILAR CONDITIONS EVEN THOUGH NOT SPECIFICALLY MARKED ON THE PLANS.
8. REPRODUCTION OF CONTRACT DRAWINGS SHALL NOT BE USED AS SHOP DRAWINGS UNDER ANY
CIRCUMSTANCE.
9. DO NOT SCALE DRAWINGS.
DESIGN CODE NOTES:
1. STRUCTURAL DESIGN IS IN ACCORDANCE WITH THE FOLLOWING CODES AND SPECIFICATIONS:
A. IBC 2015, INTERNATIONAL BUILDING CODE
B. ASCE 7-16, MINIMUM DESIGN LOADS FOR BUILDINGS AND STRUCTURES
C. ACI 318-14, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE
D. ACI 360R-10, DESIGN OF SLABS ON GRADE
E. ACI 530-13, BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES
F. AISC 360-16, SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS
G. AISI S100-12, NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD FORMED STEEL
STRUCTURAL MEMBERS
H. SDI, STEEL DECK INSTITUTE: DESIGN MANUAL FOR COMPOSITE DECK, FORM DECK,
& ROOF DECK
I. UFC 1-200-01, GENERAL BUILDING REQUIREMENTS, (1 FEB 2018)
J. UFC 3-301-01, STRUCTURAL ENGINEERING, (12 SEP 2016)
K. UFC 3-310-04, SEISMIC DESIGN OF BUILDINGS, (20 JUN 2016)
L. UFC 4-010-01, DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS,
(12 DEC 2018)
M. UFC 4-211-01, AIRCRAFT MAINTENANCE HANGARS (13 APR 2017)
DESIGN LOAD CRITERIA:
1. LIVE LOADS:
UNO, SLAB ON GRADE 150 PSF
UNO, ELEVATED SLABS 80 PSF
PARTITIONS 15 PSF (INC. IN ABOVE LOAD)
CORRIDORS/STAIRS/CONFERENCE AREAS 100 PSF
LOCKER ROOMS 100 PSF
MECHANICAL 125 PSF
ELEC/TELE. 150 PSF
AIRCRAFT UTILITY (SECOND FLOOR) 200 PSF
SHOP 250 PSF
CATWALK/ELEVATED MECH PLATFORM 40 PSF
HANGAR FLOOR: UH-60 AIRCRAFT - 40,000 PASSES
CH-47 AIRCRAFT - 20,000 PASSES
10K ATLAS FORKLIFT - 10,000 PASSES
P15 CRASH/FIRE TRUCK - 1,200 PASSES
TRANSPORT TRUCK WITH TRAILER - 1,000 PASSES
2. ROOF LIVE LOAD: 20 PSF (REDUCIBLE)
3. SNOW LOADS:
MINIMUM GROUND SNOW LOAD, Pg 0 PSF
FROST PENETRATION DEPTH 0 IN
SNOW IMPORTANCE FACTOR, Is 1.1
4. WIND LOADS:
RISK CATEGORY III
BASIC WIND SPEED, V (ULTIMATE) 148 MPH (60 MPH WITH DOORS OPEN)
WIND EXPOSURE CATEGORY C
GUST EFFECT FACTOR, G 0.85
INTERNAL PRESSURE COEFFICIENTS, GCpi +/- 0.55 FOR HANGAR (PARTIALLY ENCLOSED)
+/- 0.18 FOR ADMIN/OPERATIONS BLDG
(ENCLOSED)
5. COMPONENTS AND CLADDING WIND PRESSURES: SEE S-003
6. SEISMIC LOADS:
HANGAR PORTION:
RISK CATEGORY III
SEISMIC IMPORTANCE FACTOR, Ie 1.25 MAPPED SPECTRAL RESPONSE ACCELERATION, Ss 0.295
MAPPED SPECTRAL RESPONSE ACCELERATION, S1 0.109
SITE CLASS D
DESIGN SPECTRAL RESPONSE ACCELERATION, Sds 0.31 DESIGN SPECTRAL RESPONSE ACCELERATION, Sd1 0.17
SEISMIC DESIGN CATEGORY C
SEISMIC ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE
SEISMIC-FORCE RESISTING SYSTEM STEEL NOT SPECIFICALLY DETAILED FOR SEISMIC
RESPONSE MODIFICATION FACTOR, R 3
SYSTEM OVERSTRENGTH FACTOR 3
DEFLECTION AMPLIFICATION FACTOR, Cd 3 SEISMIC RESPONSE COEFFICIENT, Cs 0.128
SEISMIC DESIGN BASE SHEAR, V 0.128W
ADMINISTRATION AND OPERATIONS PORTION:
RISK CATEGORY III
SEISMIC IMPORTANCE FACTOR, Ie 1.25 MAPPED SPECTRAL RESPONSE ACCELERATION, Ss 0.295
MAPPED SPECTRAL RESPONSE ACCELERATION, S1 0.109
SITE CLASS D
DESIGN SPECTRAL RESPONSE ACCELERATION, Sds 0.31 DESIGN SPECTRAL RESPONSE ACCELERATION, Sd1 0.17
SEISMIC DESIGN CATEGORY C
SEISMIC ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE
SEISMIC-FORCE RESISTING SYSTEM INTERMEDIATE REINF. MASONRY SHEAR WALLS
RESPONSE MODIFICATION FACTOR, R 3.5
SYSTEM OVERSTRENGTH FACTOR 2.5
DEFLECTION AMPLIFICATION FACTOR, Cd 2.25 SEISMIC RESPONSE COEFFICIENT, Cs 0.11
SEISMIC DESIGN BASE SHEAR, V 0.11W
7. ANTI-TERRORISM/FORCE PROTECTION CRITERIA:
NEW BUILDING LOCATION MORE THAN 50 FEET FROM
INSTALLATION PERIMETER
BUILDING CATEGORY HANGAR - LOW OCCUPANCY
REMAINDER - INHABITED BUILDING
CONVENTIONAL CONSTR STANDOFF DISTANCE TBD
STEEL DOORS AND FRAMES SPEC 08 11 13
ALUMINUM DOORS AND FRAMES SPEC 08 11 16
ALUMINUM WINDOWS SPEC 08 51 13
GLAZING SPEC 08 81 00
PROGRESSIVE COLLAPSE CRITERIA APPLIES N/A (<3 STORIES)
FOUNDATION AND SLAB NOTES:
1. FOUNDATIONS FOR THIS PROJECT HAVE BEEN DESIGNED IN ACCORDANCE WITH THE
RECOMMENDATIONS IN THE GEOTECHNICAL REPORT PREPARED BY THE SOILS SECTION OF THE
SAVANNAH DISTRICT TITLED "AIRCRAFT MAINTENANCE HANGAR, P.N. 88410, FY-20, HUNTER ARMY
AIRFIELD, GA" DATED NOVEMBER 2019.
2. FOUNDATIONS HAVE BEEN DESIGNED TO BEAR ON SOIL CAPABLE OF SUPPORTING AN ALLOWABLE BEARING PRESSURE OF 2,000 PSF AS STATED IN THE GEOTECHNICAL REPORT REFERENCED ABOVE.
3. THE CONTRACTOR SHALL HIRE AN INDEPENDENT TESTING LABORATORY AND GEOTECHNICAL
ENGINEER, REGISTERED AND LICENSED IN THE STATE WHERE THE WORK WILL BE ACCOMPLISHED, TO VERIFY THAT ALL OF THE REQUIREMENTS CONTAINED IN SPECIFICATION 31 00 00, EARTHWORK, HAVE
BEEN FOLLOWED AND ACCOMPLISHED.
4. CONTRACTOR SHALL BE PREPARED FOR AND SHALL INCLUDE COST OF FORMING FOUNDATIONS
SHOULD THE EARTH NOT PROVIDE ADEQUATE BANK STABILITY.
5. ALL EXCAVATIONS SHALL BE PERFORMED SO THAT THE SITE AND THE AREA IMMEDIATELY
SURROUNDING THE SITE WHICH AFFECTS CONSTRUCTION OPERATIONS WILL BE CONTINUALLY AND
EFFECTIVELY DRAINED. THE CONTRACTOR SHALL PROVIDE DRAINAGE AND DEWATERING AS
REQUIRED TO ENSURE THAT ALL FOOTING EXCAVATIONS ARE ACCOMPLISHED WITH THE SUBGRADE SOILS REMAINING DRY AND FIRM UNTIL AFTER FOOTINGS ARE PLACED AND BACKFILLED. REMOVAL OF
SURFACE WATER, GROUNDWATER, AND ANY PERCHED WATER CONDITIONS WHICH MIGHT BE
ENCOUNTERED DURING EXCAVATIONS, SHALL BE ACCOMPLISHED BY APPROVED MEANS. REFER TO SPECIFICATION SECTION 31 00 00, EARTHWORK FOR ADDITIONAL EXCAVATION REQUIREMENTS.
6. PLACE FOUNDATION CONCRETE THE SAME DAY EXCAVATIONS ARE MADE OR AS SOON AS PRACTICAL
THEREAFTER.
7. DO NOT PLACE FOUNDATION CONCRETE ON FROZEN OR SATURATED SUBGRADES.
8. DO NOT BEGIN EXCAVATION OPERATIONS OR INSTALL FOUNDATIONS UNTIL FOUNDATION WORK HAS
BEEN COORDINATED WITH ADJACENT UNDERGROUND UTILITIES OR OTHER SUBSURFACE
STRUCTURES WITHIN THE AREA TO BE EXCAVATED.
9. ENSURE THAT EARTH-FORMED FOOTINGS CONFORM TO THE SHAPE, LINES, AND THICKNESSES INDICATED ON THE FOUNDATION PLAN, SECTIONS, AND FOOTING SCHEDULES. EXCAVATION WIDTHS
SHALL BE A MINIMUM OF 4" GREATER THAN DIMENSIONS INDICATED.
10. PLACE 15 MIL VAPOR RETARDER ON 4" COMPACTED CAPILLARY WATER BARRIER UNDER ALL INTERIOR
SLABS-ON-GRADE (TYPICAL).
11. ALL SURFACES TO RECEIVE EPOXY/RESINOUS COATINGS SHALL BE MOISTURE CURED. DO NOT USE ANY MEMBRANE CURING OR SEALER ON CONCRETE TO RECEIVE EPOXY. TEST AREAS TO RECEIVE COATINGS NO LESS THGAN 60 DAYS AFTER PLACEMENT OF CONCRETE. TEST PER ASTM F1869 TO VERIFY THAT MOISTURE VAPOR EMISSION IS NO MORE THAN 3.0 LBS MOISTURE PER 24 HOURS, 100 SQ FT. CONTRACTOR SHALL PROVIDE ADEQUATE TIME IN THE SCHEDULE TO ALLOW FOR THE CONCRETE
TO DRY TO MEET COATING REQUIREMENTS.
12. FOOTINGS SHALL BE LOWERED AS REQUIRED TO PASS UNDER UTILITY LINES. STEP CONTINUOUS
FOOTINGS DOWN AS SHOWN IN THE "TYPICAL STEPPED FOOTING DETAIL" ON SHEET SB501.
13. A POSITIVE FOUNDATION DRAINAGE SYSTEM SHALL BE PROVIDED AROUND THE PERIMETER OF THE BUILDING. THE DRAINAGE SYSTEM SHALL CONSIST OF A MINIMUM 4-INCH FLEXIBLE OR RIGID PERFORATED DRAIN PIPE CONNECTED EITHER TO CLEAN, FREE DRAINING, COURSE GRANULAR FILL
WRAPPED IN A NON-WOVEN GEOTEXTILE FABRIC OR TO A PREFABRICATED WALL DRAINAGE
GEOCOMPOSITE. THE FOUNDATION DRAINAGE SYSTEM SHALL BE TIED TO THE STORM DRAINAGE
SYSTEM.
TRENCH DRAIN NOTES:
1. TRENCH DRAIN AT HANGAR SHALL BE PREFABRICATED INCLUDING EMBEDS, ANGLES, GRATING & TRENCH, ETC AND DESIGNED BY THE TRENCH DRAIN VENDOR. TRENCH DRAIN GRATING SHALL BE
DUCTILE IRON AND SHALL BE DESIGNED BY THE TRENCH DRAIN VENDOR, MANUFACTURERED TO
WITHSTAND A MINIMUM PROOF-LOAD OF 100,000 POUNDS FROM A TIRE WITH 250 PSI PRESSURE.
COORDINATE DIMENSIONS, SLOPES, ETC WITH MECHANICAL AND PLUMBING DRAWINGS AND TRENCH DRAIN SPECIFICATION. VENDOR SHALL SUPPLY ALL ITEMS NECESSSARY FOR CONSTRUCTION OF
TRENCH DRAIN.
CONCRETE CONSTRUCTION NOTES:
1. ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE PROVISIONS OF THE "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" (ACI 318-14) AND THE SPECIFICATIONS FOR
STRUCTURAL CONCRETE (ACI 301-16) OF THE AMERICAN CONCRETE INSTITUTE (ACI).
2. ALL CAST-IN-PLACE CONCRETE SHALL ATTAIN MINIMUM 28-DAY COMPRESSIVE STRENGTH (f'c) OF 4000 PSI AND UTILIZE MAXIMUM WATER-CEMENTITIOUS MATERIAL RATIO (w/cm) OF 0.45. ALL CONCRETE EXPOSED TO WEATHER SHALL BE AIR ENTRAINED. SEE SPECIFICATIONS FOR AIR ENTRAINMENT REQUIREMENTS. MINIMUM FLEXURAL STRENGTH OF SLAB ON GRADE CONCRETE IN HANGAR IS 650
PSI AT 90 DAYS. FIBERS SHALL NOT BE USED IN SLAB ON GRADE IN THE HANGAR.
3. CONCRETE DENSITY SHALL BE NORMAL WEIGHT WITH A DENSITY OF 140 PCF TO 150 PCF UNLESS
NOTED OTHERWISE ON PLANS.
4. ALL CONCRETE FOR SECOND FLOOR SLABS (ON COMPOSITE DECK) SHALL BE LIGHTWEIGHT
CONCRETE WITH A DENSITY OF 105 PCF TO 115 PCF. ALL OTHER CONCRETE SHALL BE NORMAL
WEIGHT WITH A DENSITY OF 140 PCF TO 150 PCF.
5. CONCRETE SLAB ON GRADE JOINTS INDICATED ARE DIAGRAMMATIC AND DO NOT REPRESENT ALL OF
THE JOINTS REQUIRED FOR SLAB-ON-GRADE CONSTRUCTION.
6. CONTRACTOR SHALL PROVIDE JOINTS AT ALL RE-ENTRANT CORNERS INCLUDING, BUT NOT LIMITED TO, PIERS AND COLUMNS (AS SHOWN IN TYPICAL COLUMN ISOLATION JOINT), SLAB RECESSES, AND
CORNERS AND ENDS OF WALLS.
7. CONCRETE REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM A615/A615M, GRADE 60 AND SHALL HAVE FABRICATION TOLERANCES IN ACCORDANCE WITH ACI 315. SHOP
FABRICATE REINFORCING BARS WHICH ARE INDICATED TO BE BENT OR HOOKED.
8. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 OR ASTM A497. PROVIDE SHEET-TYPE WELDED
WIRE FABRIC. SHEET LAPS SHALL BE TIED AND LAPPED ONE FULL MESH SPACING PLUS 2".
9. CONCRETE REINFORCING STEEL SHALL BE CONTINUOUS UNLESS OTHERWISE INDICATED.
CONTINUOUS REINFORCING STEEL SHALL BE LAPPED IN ACCORDANCE WITH THE REQUIREMENTS OF ACI 318. REINFORCING STEEL SHALL BE PLACED SO THAT SPACING IS GREATER THAN OR EQUAL TO 2X
BAR DIAMETER.
10. MINIMUM CONCRETE COVER FOR REINFORCING STEEL SHALL BE AS INDICATED. IN NO CASE SHALL
REINFORCEMENT COVER BE LESS THAN THE REQUIREMENTS OF ACI 301.
A. CONCRETE DEPOSITED AGAINST THE GROUND 3"
B. CONCRETE EXPOSED TO EARTH OR WEATHER 2"
C. BEAM AND COLUMNS 1.5"
D. SLABS AND WALLS (NOT EXPOSED TO EARTH OR WEATHER) 1"
11. CONCRETE REINFORCING STEEL MARKED STANDARD HOOK SHALL HAVE A 90° HOOK A MINIMUM OF 12 BAR DIAMETERS IN LENGTH, UNLESS OTHERWISE NOTED. STIRRUPS, TIES, AND 180° HOOKS SHALL
CONFORM TO THE REQUIREMENTS OF ACI 318.
12. PROVIDE 1/2" THICK PRE-MOLDED JOINT FILLER MATERIAL WHERE SOG ABUT VERTICAL SURFACES.
13. ALL EMBEDDED ITEMS SHALL BE PROPERLY PLACED, ACCURATELY POSITIONED AND MAINTAINED
SECURELY IN PLACE PRIOR TO AND DURING CONCRETE PLACEMENT.
14. REINFORCING STEEL SHALL BE SPREAD AT SLEEVES, ANCHORS, RECESSES AND OTHER EMBEDDED
ITEMS UNLESS OTHERWISE INDICATED. REINFORCEMENT SHALL NOT BE CUT TO FACILITATE
PLACEMENT OF EMBEDDED ITEMS, UNLESS INDICATED.
15. NO CONCRETE SHALL BE PLACED UNTIL THE OWNER OR THE CONTRACTING OFFICER'S DESIGNATED
REPRESENTATIVE HAS INSPECTED ALL EMBEDDED WORK, INCLUDING REINFORCEMENT.
16. ALL EXPOSED CONCRETE EDGES SHALL BE CHAMFERED 3/4" OR AS INDICATED.
17. ALUMINUM SHALL NOT BE PLACED IN DIRECT CONTACT WITH CONCRETE UNLESS EFFECTIVELY
COATED OR COVERED TO PREVENT ALUMINUM-CONCRETE REACTION AND ELECTROLYTIC ACTION
BETWEEN ALUMINUM AND STEEL.
18. CONCRETE SLAB ON GRADE JOINTS INDICATED ARE DIAGRAMMATIC AND DO NOT REPRESENT ALL OF THE JOINTS REQUIRED FOR SLAB-ON-GRADE CONSTRUCTION. SLAB PANELS BETWEEN JOINTS SHALL
BE SQUARE OR NEARLY SO AND SHALL NOT EXCEED AN ASPECT RATIO WITH PANEL LENGTH
GREATER THAN 1.5 TIMES THE PANEL WIDTH. MAXIMUM JOINT SPACING SHALL BE 15 FT UNLESS
NOTED OTHERWISE.
19. CONTRACTOR SHALL PROVIDE JOINTS AT ALL RE-ENTRANT CORNERS INCLUDING, BUT NOT LIMITED
TO, COLUMNS AND SLAB RECESSES.
20. IN ADDITION, CONTRACTOR SHALL COORDINATE SLAB ON GRADE JOINT REQUIREMENTS WITH SLAB-
ON-GRADE CONSTRUCTION SEQUENCING. CONTRACTOR SHALL SHOW JOINT LAYOUT ON
REINFORCING SHOP DRAWING SUBMITTAL FOR APPROVAL.
21. REFER TO CONCRETE SPECIFICATIONS FOR HOT OR COLD WEATHER CONSTRUCTION PROCEDURES.
POST INSTALLED ANCHOR NOTES:
1. CONTRACTOR SHALL PROVIDE ANCHOR OF THE SIZE AND TYPE INDICATED IN THE DRAWINGS THAT MEET OR EXCEED THE INDICATED LOADS. THE CAPACITY OF THE ANCHOR SHALL BE MODIFIED BASED ON EMBEDMENT, EDGE DISTANCE AND SPACING OF THE ANCHOR. PRODUCT DATA AND CALULATIONS FOR THE PROPOSED ANCHOR SHALL BE SUBMITTED AT LEAST 30 DAYS PRIOR TO INSTALLATION OF THE POST INSTALLED ANCHOR. SUBMIT ANCHOR DESIGN CALCULATIONS SEALED BY A PROFESSIONAL
ENGINEER.
2. CONTRACTOR SHALL LOCATE REBAR IN CONCRETE OR CMU PRIOR TO DRILLING HOLES SO AS TO NOT
DAMAGE THE REINFORCING STEEL.
3. ALL MECHANICAL ANCHORS ANCHORED INTO CONCRETE SHALL HAVE BEEN TESTED IN ACCORDANCE
WITH ACI355.2 AND/OR ICC-ES AC193 FOR CRACKED OR UNCRACKED CONCRETE AND SESMIC
APPLICATIONS. MECHANICAL ANCHORS IN CONCRETE SHALL BE DESIGNED FOR AN ULTIMATE SHEAR
LOAD OF 3,000 LBS OR AN ULTIMATE TENSION LOAD OF 2,000 LBS UNO.
4. ALL MECHANICAL ANCHORS ANCHORED INTO GROUT-FILLED CMU SHALL HAVE BEEN TESTED IN
ACCORDANCE WITH ICC-ES AC01 (EXPANSION ANCHORS) OR ICC ES AC106 (SCREW ANCHORS).
MECHANICAL ANCHORS IN GROUT-FILLED CMU SHALL BE DESIGNED FOR AN ALLOWABLE SHEAR LOAD
OF 2,000 LBS OR AN ALLOWABLE TENSION LOAD OF 1,500 LBS UNO.
5. SEE SECTIONS AND DETAILS WHERE ANCHORS SHALL SUPPORT COMBINED SHEAR AND TENSION
LOADS.
6. POST INSTALLED ANCHORS SHALL NOT BE INSTALLED IN HEAD JOINTS OF CMU.
7. POST INSTALLED ANCHORS SHALL NOT BE INSTALLED IN UNGROUTED CMU.
8. FOLLOW MANUFACTURER'S WRITTEN INSTRUCTIONS FOR INSTALLATION OF ALL POST INSTALLED
ANCHORS.
9. ALL ANCHORS INTO CONCRETE SHALL BE APPROVED FOR USE IN CRACKED CONCRETE AND SHALL BE
DESIGNED FOR CRACKED CONCRETE UNO.
10. A MANUFACTURER'S REPRESENTATIVE SHALL BE ONSITE TO PROVIDE ONSITE TRAINING FOR ALL OF THE ANCHORING PRODUCTS TO BE USED ON THE PROJECT. ALL PERSONNEL WHO INSTALL ANCHORS SHALL BE TRAINED A MINIMUM OF 1 WEEK PRIOR TO COMMENCEMENT OF ANCHOR INSTALLATION.
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6enxmdz\Desktop\Tele-Work Revit Projects\Hun400 (PN88410)\FY20PN88410_STRUC_R18_TW Current.rvt8/18/2020 11:55:14 AM
JU
LY
W
2H N
-2 0-
R -3
M . Z
AI
TZ
M . Z
AI
TZ
R . H
AL
LM
AN
1-
-0
S-001
G
EN
ER
AL
S
TR
U C
TU
R
AL
N
O
TE
S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
H U
N
TE
R A
R M
Y
AI
R
FI
EL
D
, G
EO
R G
IA
AA
B
AI
R C
R
AF
T M
AI
N
TE
N
AN
C
E H
AN
G
AR
FY
0, P N
VO
LU
M
E
-B U
IL
D
IN
G
(S
TR
U C
TU
R
AL
, A
R C
H
IT
EC
TU
R E, IN
TE
R
IO
R D
ES
IG
N A
N D
F
IR
E
PR
O
TE
C
TI
O N
J.
W H
IT
TA
KE
R
READY TO ADVERTISE (RTA)
M
AR
K D
ES
C
R
IP
TI
O
N D
SPECIAL INSPECTION NOTES:
1. INSPECTION OF FABRICATORS SHALL BE CONDUCTED IN ACCORDANCE WITH IBC 2015,
SECTION 1704.2.5.
2. INSPECTION OF STEEL CONSTRUCTION SHALL BE CONDUCTED IN ACCORDANCE WITH IBC 2015, SECTION 1705.2.
3. INSPECTION OF CONCRETE CONSTRUCTION SHALL BE CONDUCTED IN ACCORDANCE WITH IBC 2015, SECTION 1705.3 AND TABLE 1705.3.
4. INSPECTION OF MASONRY CONSTRUCTION SHALL BE CONDUCTED IN ACCORDANCE WITH IBC 2015, SECTION 1705.4.
5. INSPECTIONS FOR WIND AND SEISMIC RESISTANCE SHALL BE AS PER IBC 2015, SECTION 1705.11
AND 1705.12.
6. INCLUDE SPECIAL INSPECTIONS REQUIREMENTS IN CONTRACTOR'S QUALITY CONTROL (CQC)PLAN.
7. THE CONTRACTOR SHALL RETAIN THIRD PARTY QUALITY CONTROL AGENCIES TO CONDUCT SPECIAL
INSPECTIONS REQUIRED BY IBC. INSPECTING AGENCY SHALL PROVIDE REPORTS OF SPECIAL
INSPECTIONS DIRECTLY TO THE GOVERNMENT.
STRUCTURAL ABBREVIATIONS
SYMBOL DESCRIPTION
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
APPROX APPROXIMATELY
ARCH ARCHITECTURAL
BOC BOTTOM OF CONCRETE
BOF BOTTOM OF FOOTING
BOM BOTTOM OF MASONRY
BOS BOTTOM OF STEEL
BOT BOTTOM
BRG BEARING
BTWN BETWEEN
CJ CONSTRUCTION JOINT
CL CENTER LINE
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONN CONNECTION
CONC CONCRETE
CONT CONTINUOUS
CONSTR CONSTRUCTION
DCJ DOWELED CONSTRUCTION JOINT
DEG DEGREE
DIA DIAMETER
DN DOWN
DWG(S) DRAWING(S)
EA EACH
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
EOF EDGE OF FOUNDATION
EOS EDGE OF SLAB
EQ EQUAL
ERV ENERGY RECOVERY VENTILATOR
EW EACH WAY
FF FINISHED FLOOR
FDN FOUNDATION
FTG FOOTING
GA GAUGE
GALV GALVANIZED
GFGI GOVT
HORIZ HORIZONTAL
IJ ISOLATION JOINT
SYMBOL DESCRIPTION
KIP (k) 1000 POUNDS
LG LONG
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
MAX MAXIMUM
MBM METAL BUILDING MANUFACTURER
MECH MECHANICAL
MEP MECHANICAL, ELECTRICAL, PLUMBING
MFR MANUFACTURER
MIN MINIMUM
NTS NOT TO SCALE
OC ON CENTER
OPP OPPOSITE
PJF PREMOLDED JOINT FILLER
PL PLATE
PLF POUNDS PER LINEAR FOOT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
REINF REINFORCEMENT
REQD REQUIRED
SCHED SCHEDULE
SE SLAB EDGE
SJ SAWED CONTRACTION JOINT
SJI STEEL JOIST INSTITUTE
SIM SIMILAR
SL SLOPE(D)
SOG SLAB ON GRADE
SPCG SPACING
SPCS SPACES
STD STANDARD
T&B TOP AND BOTTOM
TO TOP OF
TOC TOP OF CONCRETE
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOS TOP OF SLAB
T/STEEL TOP OF STEEL
TS THICKENED SLAB
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VEF VEHICLE EXHAUST FAN
VERT VERTICAL
WP WORKING POINT
WWF WELDED WIRE FABRIC
STRUCTURAL LEGEND
SLOPE DIRECTION
INDICATES ELEVATION
REFERENCED
TO FINISHED FLOOR
KEYED PLAN NOTE
COLUMN REFERENCE LINE
(CENTER LINE OF COLUMN)
SPOT ELEVATION
DECK SPAN DIRECTION
DN
X
[+/- X’-X”]
X
[+/- X’-X”]
SLAB DEPRESSION
BRICK WALL
CONCRETE ELEMENT
COMPACTED EARTH FILL
GROUT
CONCRETE MASONRY UNIT
(CMU)
POROUS FILL
WELDED WIRE FABRIC (WWF)
AISC SHAPE DESIGNATION
INDICATES # OF SHEAR STUDS WELDED
TO TOP FLANGE OF BEAM PER
GENERAL NOTES
HSSXxX
AISC COLUMN
DESIGNATION
STEEL COLUMN
BRACED FRAME LOCATION
BRACED/MOMENT
FRAME
STEEL FRAMING REFERENCE
WXxXX [XX]
(B/M)F
[X]
BEAM END REACTION
[X]
MOMENT CONNECTION
DESIGNATION
CRANE DESIGN NOTES:
1. TWO BRIDGE CRANES IN HANGAR SHALL BE UNDERHUNG WITH CAPACITY OF 10 TONS (IMPERIAL).
BRIDGE CRANE IN POWER PLANT/POWER TRAIN SHOP SHALL BE TOP RUNNING WITH A CAPACITY OF 2
TONS (IMPERIAL).
2. CRANES IN HANGAR SHALL HAVE MINIMUM CLEARANCE HEIGHT OF 28’-0” AFF. THE OVERHEAD BRIDGE
CRANE IN THE SHOP SHALL HAVE A MINIMUM HOOK HEIGHT OF 12'-0" AFF.
3. CRANE SHALL BE DESIGNED FOR A CRANE SERVICE DUTY CLASSIFICATION OF CLASS C (MODERATE
SERVICE) AS DEFINED BY THE CRANE MANUFACTURER’S ASSOCIATION OF AMERICA (CMAA).
4. THE BRIDGE CRANE, RUNWAY BEAMS AND THE RUNWAY BEAM TO TRUSS CONNECTIONS SHALL BE DESIGNED BY THE BRIDGE CRANE VENDOR. THE NOTED ITEMS SHALL BE DESIGNED FOR THE TOTAL VERTICAL LOAD FROM THE WEIGHT OF THE BRIDGE, TROLLEY HOIST, AND RATED CAPACITY OF THE CRANE. TOTAL VERTICAL LOAD SHALL BE ADJUSTED FOR THE FOLLOWING IMPACT LOAD FACTOR EXPRESSED AS A PERCENTAGE OF THE TOTAL VERTICAL LOAD. CRANE RUNWAY BEAMS AND RAILS
SHALL ALSO BE DESIGNED FOR A LATERAL AND LONGITUDINAL FORCE EQUIVALENT TO A
PERCENTAGE OF THE TOTAL VERTICAL LOAD AS SHOWN BELOW. SEE ASCE 7-16, SECTION 4.9 FOR
DETAILS.
VERTICAL IMPACT FORCE 125%
LATERAL FORCE 20%
LONGITUDINAL FORCE 10%
5. PROVIDE END STOPS AT EACH END OF CRANE RAIL. END STOPS SHALL BE DESIGNED FOR LOADS
REQUIRED FOR THE CRANE PROVIDED. CONTRACTOR SHALL COORDINATE LOCATIONS OF CRANE
STOPS WITH CRANE PROVIDER..
LIGHT GAUGE STEEL NOTES:
1. WALL LAYOUT AND COMPONENTS SHOWN ON THE DRAWINGS ARE FOR GENERAL CONFIGURATION ONLY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DIMENSIONS, ELEVATIONS, CONNECTION DETAILS, QUANTITIES, ETC. NECESSARY FOR THE COMPLETE DESIGN, FABRICATION, AND ERECTION
OF THE FRAMING SYSTEM. THE CONTRACTOR SHALL COORDINATE THE DESIGN WITH THE
ARCHITECTURAL PLANS, ELEVATIONS, AND DETAILS. DESIGN SHALL BE COORDINATED WITH THE
MECHANICAL CONTRACTOR AND WEB MEMBERS SHALL BE COORDINATED TO ACCOMODATE
EQUIPMENT, DUCTS, AND PIPES, AS REQUIRED. COORDINATE MEP LAYOUTS WITH EQUIPMENT
SUPPLIERS.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE EXTERIOR STUD WALL FRAMING TO INCLUDE ALL ELEVATIONS, QUANTITIES, DIMENSIONS, CONNECTION DETAILS, ETC. NECESSARY FOR THE COMPLETE DESIGN, FABRICATION, AND ERECTION OF THE EXTERIOR STUD WALL FRAMING. THE CONTRACTOR SHALL COORDINATE THE DESIGN WITH THE ARCHITECTURAL PLANS, ELEVATIONS, AND DETAILS.
3. COLD-FORMED EXTERIOR STUD WALLS SHALL BE DESIGNED IN ACCORDANCE WITH THE AMERICAN IRON AND STEEL INSTITUTE (AISI) SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL
STRUCTURAL MEMBERS.
4. LIGHT GAUGE FRAMING MEMBERS SHALL BE DESIGNED IN ACCORDANCE WITH THE AMERICAN IRON AND STEEL INSTITUTE (AISI) SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL
MEMBERS.
5. ALL CALCULATIONS AND DRAWINGS USED IN THIS DESIGN MUST BE SIGNED AND STAMPED BY A PROFESSIONAL ENGINEER AND SUBMITTED FOR APPROVAL. IN ADDITION TO THE CALCULATIONS, THE SUBMITTAL SHALL INCLUDE DETAILS OF THE CONNECTIONS, ERECTION PLAN, LAYOUT, OUTRIGGERS, BRIDGING, AND BOTH TEMPORARY AND PERMANENT BRACING INCLUDING DIAPHRAGM FORCES, HEADERS, SILLS, AND JAMBS.
6. THE CONTRACTOR SHALL SUBMIT COMPLETE PRODUCT CATALOGS FROM THE MATERIAL
MANUFACTURER FOR REVIEW PRIOR TO FABRICATION. THE CATALOGS SHALL INDICATE
QUALIFICATION, MATERIAL SPECIFICATIONS, DESIGN REFERENCES, ETC.
7. ALL COLD-FORMED STEEL MEMBERS, THEIR COMPONENTS, AND CONNECTION MATERIAL SHALL BE
GALVANIZED. PREPARE AND REPAIR DAMAGED GALVANIZED COATINGS ON FABRICATED AND
INSTALLED LIGHT GAUGE METAL FRAMING WITH GALVANIZING REPAIR PAINT ACCORDING TO ASTM
A780 AND/OR THE MANUFACTURER'S RECOMMENDATIONS.
8. COLD-FORMED STEEL MEMBERS SHALL BE Fy=33KSI FOR MEMBERS 43 MILS (18 GA) AND Fy=50KSI FOR MEMBERS 54 MILS (16 GA) AND HEAVIER. USE MIN 8" WIDE STUDS AT EXTERIOR WALLS UNO.
9. COLD-FORMED STEEL STUD MEMBERS SHALL BE DESIGNED TO ACCOMODATE VERTICAL AND
HORIZONTAL LOADS DUE TO METAL WALL PANELS AND ARCHITECTURAL FEATURES. COORDINATE
DESIGN CRITERIA WITH ARCHITECTURAL DRAWINGS AND DETAILS. OUT OF PLANE DEFELCTION FOR STUDS BACKING BRICK SHALL NOT EXCEED L/600. OUT OF PLANE DEFELCTION FOR STUDS BACKING
METAL PANELS SHALL NOT EXCEED L/240.
10. ALL WELDING OF LIGHT GAUGE STEEL SHALL COMPLY WITH AWS D1.1 AND AWS D1.3 FOR WELDING
BASE MATERIAL LESS THAN 1/8" THICK.
11. THE CONTRACTOR SHALL COORDINATE THE DESIGN WITH ARCHITECTURAL, MECHANICAL AND
ELECTRICAL FOR WALL LAYOUT.
12. LIGHT GAUGE STEEL STUD MEMBERS SHALL BE DESIGNED TO ACCOMODATE VERTICAL AND
HORIZONTAL LOADS DUE TO METAL WALL PANELS AND ARCHITECTURAL FEATURES. COORDINATE
DESIGN CRITERIA WITH ARCHITECTURAL DRAWINGS AND DETAILS. REFER TO UFC 4-010-01 FOR
ADDITIONAL OUT OF PLANE DEFLECTION CRITERIA.
STEEL CONSTRUCTION NOTES:
1. FABRICATION AND ERECTION OF STRUCTURAL STEEL AND DESIGN OF CONNECTIONS SHALL BE IN ACCORDANCE WITH AISC 360-16, "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" AND AISC 303-16, "CODE OF STANDARD PRACTICE FOR BUILDING AND BRIDGES". THE STRUCTURAL STEEL MEMBERS SHOWN IN THESE DRAWINGS HAVE BEEN ANALYZED AND DESIGNED USING AISC 360-16
LRFD METHOD.
2. UNLESS OTHERWISE NOTED, STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH THE ABOVE-LISTED
AISC SPECIFICATION AND THE FOLLOWING:
A. WIDE FLANGE SHAPES (50 KSI) ASTM A992
B. HSS HOLLOW SHAPES (50 KSI) ASTM A500, GR C
C. PLATES AND ANGLES ASTM A36
D. HIGH STRENGTH BOLTS ASTM F3125
E. ANCHOR RODS W/ NUT AND WASHER ASTM F1554, GRADE 55
3. IT IS THE INTENTION OF THESE DESIGN DOCUMENTS TO DELEGATE THE DESIGN OF ALL STRUCTURAL
STEEL CONNECTIONS TO A QUALIFIED REGISTERED ENGINEER RETAINED BY THE CONTRACTOR
AND/OR FABRICATOR. SIGNED AND SEALED CALCULATIONS FOR CONNECTION DESIGNS SHALL BE
SUBMITTED SIMULTANEOUSLY WITH FABRICATION DRAWINGS FOR REVIEW. UNLESS NOTED
OTHERWISE ON PLANS, ALL SHEAR CONNECTIONS FOR SIMPLY SUPPORTED BEAMS SHALL BE
DESIGNED TO DEVELOP THREE QUARTERS (3/4) OF THE MAXIMUM ALLOWABLE UNIFORM LOAD
CAPACITY FOR THE BEAM SIZE AND SPAN SHOWN, ASSUMING FULL LATERAL SUPPORT, AS TABULATED
IN THE ALLOWABLE UNIFORM LOAD TABLES OF THE AISC MANUAL, 15TH EDITION. ALL STEEL
CONNECTIONS SHOWN ON THE DRAWINGS ARE CONCEPTUAL IN NATURE AND DO NOT DICTATE
DESIGN INTENT IN TERMS OF NUMBER OF BOLTS, WELD SIZES, ANGLE SIZE, ETC. THE DELGATED ENGINEER IS SOLELY RESPONSIBLE FOR THE DESIGN OF THE CONNECTIONS FOR THE CRITERIA
INDICATED ON THE DRAWINGS. CONNECTIONS SHALL HAVE A MINIMUM OF 2 BOLTS IN THE
CONNECTION.
4. THE FABRICATORS CONNECTION ENGINEER SHALL REVIEW AND CONFIRM IN WRITING THAT THE SHOP
DRAWINGS PROPERLY AND COMPLETELY INCORPORATE THE CONNECTION DESIGNS.
5. ALL SHOP AND FIELD WELDING SHALL BE BY CERTIFIED WELDERS AND SHALL CONFORM TO AWS
STANDARDS. USE E70XX ELECTRODES UNLESS OTHERWISE NOTED. MINIMUM WELD SIZE FOR
STRUCTURAL STEEL IS 3/16" FILLET, UNLESS OTHERWISE NOTED ON PLANS. CURRENT AWS
CERTIFICATIONS SHALL BE AVAILABLE AT THE JOB SITE FOR REVIEW BY THE OWNERS'
REPRESENTATIVE.
6. ALL BOLTED CONNECTIONS, UNLESS OTHERWISE NOTED, SHALL USE 3/4" DIAMETER HIGH STRENGTH
BOLTS WITH HARDENED CARBON STEEL WASHERS AS REQUIRED. BEAM CONNECTIONS SHALL
CONSIST OF ALL-BOLTED DOUBLE-ANGLE CONNECTIONS UNLESS NOTED OTHERWISE. SHEAR
CONNECTIONS BETWEEN BEAMS AND HSS HOLLOW COLUMNS SHALL UTILIZE WT SECTIONS OFFSET
SUCH THAT THE CENTERLINE OF THE BEAM AND CENTERLINE OF THE COLUMN ALIGN.
7. FIELD CUTTING OF STRUCTURAL STEEL MEMBERS BY ANY TRADE SHALL NOT BE PERMITTED. BOLT
HOLES SHALL NOT BE CUT OR ENLARGED BY FLAME CUTTING IN THE FIELD.
8. ALL FIELD-BOLTED SHEAR CONNECTIONS SHALL BE SNUG TIGHT BEARING-TYPE CONNECTIONS, THREADS INCLUDED IN THE SHEAR PLANE.
9. THE CONTRACTOR SHALL SUBMIT FOR APPROVAL DRAWINGS AND DESIGN CALCULATIONS FOR ANY ALTERNATE DETAILS AND MEMBER SPLICES. DRAWINGS AND CALCULATIONS SHALL BE SEALED BY AN
ENGINEER LICENSED IN THE STATE OF THE PROJECT.
10. SHOP OR FIELD SPLICES OF STRUCTURAL STEEL MEMBERS ARE PROHIBITED EXCEPT AS DETAILED ON THE DRAWINGS, PERMITTED IN THE SPECIFICATIONS, AS INDICATED ON APPROVED SUBMITTALS, AND
AS SPECIFICALLY APPROVED ON SHOP DRAWINGS PRIOR TO FABRICATION.
11. PAINT ALL STEEL BELOW GRADE WITH BITUMINOUS COATING.
12. ALL STEEL EXPOSED TO WEATHER SHALL BE HOT-DIPPED GALVANIZED IN ACCORDANCE WITH ASTM A123 FOR MEMBERS AND ASTM A153 FOR CONNECTION ELEMENTS, EXCEPT THAT ARCHITECTURALLY EXPOSED STRUCTURAL STEEL SHALL BE BLAST CLEANED AND COATED IN ACCORDANCE WITH THE
STRUCTURAL STEEL AND PAINT SPECIFICATIONS. COORDINATE ALL STEEL FINISHES WITH
ARCHITECTURAL DRAWINGS AND SPECIFICATIONS.
13. ALL BEAMS TO RECEIVE STUDS ON THEM (COMPOSITE BEAMS) SHALL NOT BE PAINTED ON THEIR TOP FLANGE. ALL STEEL MEMBERS TO RECEIVE FIRE PROOFING SHALL NOT BE PAINTED. COORDINATE
MEMBERS REQUIRING FIRE PROOFING WITH THE ARCHITECTURAL DRAWINGS.
14. ALL ANGLES AND BENT PLATES INDICATED TO BE CONTINUOUS SHALL HAVE SPLICES FULLY WELDED.
15. REFER TO SPECIFICATION 05 12 00 FOR ADDITIONAL INFORMATION.
16. ENDS OF ALL HSS MEMBERS IN THE HANGAR SHALL BE SEALED WITH 3/16" CAP PLATES.
17. ALL DOUBLE ANGLES SHALL HAVE BOLTED (PRETENSIONED) STITCH PLATES BETWEEN THEM THE SAME THICKNESS AS THE GUSSET PLATES AT THE CONNECTIONS. USE A MINIMUM OF 2 STITCH
PLATES AT ONE THIRD POINTS UNLESS NOTED OTHERWISE.
SHEAR STUD CONNECTOR NOTES:
1. SHEAR STUD CONNECTORS SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH AWS D1.1
"STRUCTURAL WELDING CODE", SECTION 7 - STUD WELDING.
2. ATTACHMENT OF STUDS SHALL BE SUFFICIENT TO DEVELOP THE FULL CAPACITY OF EACH INDIVIDUAL
STUD.
3. STUDS SHALL BE TYPE 'B', HEADED STUDS HAVING A MINIMUM TENSILE STRENGTH OF 65,000 PSI AND
SHALL BE OF LENGTH AND DIAMETER SHOWN ON STRUCTURAL DRAWINGS.
4. FABRICATOR SHALL SUBMIT SHOP DRAWINGS FOR REVIEW AND APPROVAL WHICH INDICATES THE
SIZE, LENGTH, AND LOCATION OF SHEAR CONNECTOR STUDS.
STEEL JOIST NOTES:
1. DESIGN, FABRICATION, AND ERECTION OF JOISTS SHALL BE IN ACCORDANCE WITH SJI
SPECIFICATIONS.
2. ALL ROOF JOISTS, JOIST EXTENSIONS AND JOIST SUBSTITUTES SHALL BE DESIGNED BY THE STEEL
JOIST FABRICATOR FOR THE DESIGN LOADS NOTED ON THE DRAWINGS UNO INCLUDING:
1. ROOF COLLATERAL DEAD LOAD OF 20 PSF
ROOF COLLATERAL DEAD LOAD OF 7 PSF FOR UPLIFT CALCULATIONS
2. ROOF LIVE LOAD OF 20 PSF WITH LIVE LOAD DEFLECTION LESS THAN L/360. MAXIMUM
DEFLECTION FOR D+L = L/360. MAX DEFLECITION FOR JOISTS NEAR PARALLEL WALL
SHALL BE L/480.
3. NET UPLIFT PRESSURES, GROSS UPLIFT PRESSURES INDICATED ON S-003.
4. POSITIVE WIND PRESSURES INDICATED ON S-003.
5. JOISTS SHALL BE DESIGNED FOR LOAD COMBINATIONS REQUIRED PER ASCE, IBC AND
UFC.
3. JOISTS, JOIST EXTENSIONS AND JOIST SUBSTITUTES SHALL BE DESIGNED TO THE INDICATED SLOPES
AND FOLLOWING CRITERIA. ROOF JOISTS SIZES SHOWN ON DRAWINGS ARE PROVIDED FOR
ESTIMATING PURPOSES, HOWEVER SHALL BE MINIMUM REQUIRED AND ANY CHANGE REQUIRED SHALL
BE SUBJECT TO CONTRACTING OFFICER APPROVAL.
4. HANGERS FOR SUPPORT OF EQUIPMENT OR MEMBER SUPPORTING SUCH HANGERS, SHALL BE
LOCATED AT PANEL POINTS OF JOISTS, AND SHALL BE HUNG FROM THE TOP CHORD OF JOISTS.
5. JOIST DESIGN SHALL INCLUDE ALL REQUIRED JOIST BRIDGING INCLUDING UPLIFT BRIDGING. BRIDGING
SHALL BE SIZED, SPACED, AND…