ATTACHMENT 1.12 DRAFT - APPENDIX F- COMPONENT UNIQUE IDENTIFIER.pdf

PDF 204 KB Posted

Attached to
FUEL PROGRAM RECURRING MAINTENANCE AND MINOR REPAIR
Solicitation number
W912DY25RRMMR
Issued by

About this file

This document appears to be Appendix F - Component Unique Identifier (CUID) from a federal contract opportunity. It provides a detailed list of component acronyms and their corresponding Unified Facilities Criteria (UFC) section references for various equipment and systems associated with federal petroleum facilities and petroleum systems. The CUID is the standard for all DLA capitalized equipment and contractors may use additional tracking/labeling methods as long as they correlate to the CUID.

The related federal contract opportunity is for the Fuel Program Recurring Maintenance and Minor Repair (RMMR) program, which provides comprehensive maintenance and repair services for the U.S. Government's worldwide fueling capability. The program is divided into Recurring Maintenance, following UFC 3-460-03 criteria, and Minor Repair, providing corrective action for deficiencies. The contract requires experience in repair, maintenance, and operation of federal petroleum facilities and systems to ensure compliance with applicable codes, criteria, regulations, and laws. This acquisition does not include Architect/Engineering or construction services.

View the file

Other files

File Type Posted
ATTACHMENT 1.11 DRAFT -APPENDIX E ISR 15-BULK FUEL FACILITIES FY24 20240902.pdf PDF
AMENDMENT 0001 0002 FUELS RMMR SOURCES SOUGHT.pdf PDF
ATTACHMENT 1.14 DRAFT - APPENDIX H - MINOR REPAIRS INCIDENTAL TO MAINTENANCE ACTIVITIES.pdf PDF
ATTACHMENT 1.2 DRAFT - APPENDIX A - CONTRACTOR TRAVEL EXPENSE REPORT.pdf PDF
ATTACHMENT 1.16 DRAFT - APPENDIX K - REAL PROPERTY DATA.pdf PDF
ATTACHMENT 1 - DRAFT - FUELS RMMR PWS.pdf PDF
ATTACHMENT 1.1 DRAFT - APPENDIX A - SERVICE ORDER FORM.pdf PDF
FUELS RMMR SOURCES SOUGHT.pdf PDF
ATTACHMENT 2. USACE MAINTENANCE ENGAGEMENT MAP.pdf PDF
ATTACHMENT 1.6 DRAFT - APPENDIX B - SERVICE ORDER TRACKER.pdf PDF
ATTACHMENT 1.17 DRAFT - APPENDIX L - EXISTING FACILITY MAINTENANCE PLANS.pdf PDF
ATTACHMENT 1.13 DRAFT - APPENDIX G_UFC 3-460-03 MAINTENANCE TABLE.pdf PDF
ATTACHMENT 1.15 DRAFT - APPENDIX I AND J SITE LIST AND EXISTING RECURRING MAINTENANCE SCHEDULES _20240902.pdf PDF
ATTACHMENT 1.9 DRAFT - APPENDIX D ANTITERRORISM_OPERATIONS SECURITY COMPLIANCE AND INSTALLATION ACCESS.pdf PDF
ATTACHMENT 1.4 - DRAFT - APPENDIX B - MONTHLY REPORT FORMAT.pdf PDF
ATTACHMENT 1.8 DRAFT - APPENDIX C TASK ORDER SPECIFICATIONS.pdf PDF
ATTACHMENT 1.7 DRAFT - APPENDIX C 01 33 00 SUBMITTAL REQUIREMENTS.pdf PDF
ATTACHMENT 1.5 DRAFT - APPENDIX B - RECURRING MAINTENANCE REPORT TEMPLATE.pdf PDF
ATTACHMENT 1.3 DRAFT - APPENDIX B - THREE WEEK LOOK AHEAD.pdf PDF
ATTACHMENT 1.10 DRAFT - APPENDIX E ISR 14-OPERATIONAL FUEL FACILITIES FY24.pdf PDF
Map RMMR Maintenance Engagement.pdf PDF
Draft - Appendix G_UFC 3-460-03 Maintenance Table.pdf PDF
Draft - Appendix B - Attachment 3 Recurring Maintenacne Report Template.pdf PDF
Draft - Appendix B - Attachment 4 - Service Order Tracker.pdf PDF
FUELS RMMR SOURCES SOUGHT.pdf PDF
Draft - Appendix B - Attachment 1 - Three Week Look Ahead.pdf PDF
Draft - Appendix C 01 33 00 Submittal Requirements.pdf PDF
Draft - Appendix A - Attachment 2 Contractor Travel Expense Report.pdf PDF
Draft - Appendix K - Real Property Data.pdf PDF
Draft - Appendix E ISR 14-Operational Fuel Facilities FY24.pdf PDF
Draft - RMMR PWS.pdf PDF
Draft - Appendix A - Attachment 1 Service Order Form.pdf PDF
Draft - Appendix L - Existing Facility Maintenance Plans.pdf PDF
Draft - Appendix C Task Order Specifications.pdf PDF
Draft - Appendix F- Componet Unique Identifier.pdf PDF
Draft - Appendix B - Attachment 2 - Monthly Report Format.pdf PDF
Draft - Appendix H - Minor Repairs Incidental to Maintenance Activities.pdf PDF
Draft - Appendix D Antiterrorism_Operations Security Compliance and Installation Access.pdf PDF
Draft - Appendix I and J Site List and Existing Recurring Maintenance Schedules _20240902.pdf PDF
Show all 39

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

APPENDIX F - Component Unique Identifier (CUID)

Component Unique Identifier:

Example:

DLA Work Type Category UFC Section Reference Work Category (Revised per Change 1, 29 April 2021)

Component Acronym

Air Compressors Air Compressors AIRC Externally Mounted Level Alarms (Section 8-9.9.1) EMLA

Internally Mounted Level Alarms (Section 8-9.9.3) IMLA

Bollard Bollards BLRD Building HVAC BHVAC Building Domestic Water System BWTR Building Waste Water BWSW Building - Lighting BLTG Building - Architectural BARCH Building - Fire Sprinkler System BFIRE Containment Systems (General) (Section 8-10.1) CSGEN Concrete and Cement Brick Dike/Berm Walls (Section 8-

10.2.1) DKBW

Dike/Berm Floors (Section 8-10.2.2) DKBF Earthen Dike Walls (Section 8-10.3) ETHDW Self-Diking or Vaulted Tank Containment (Section 8-10.4) SDVTCS Flexible Membrane Liners (Section 8-10.5) FXML

Fuel Truck and Rail Car Containment Areas (Section 11-1.1) FTKRCC

Remote Spill Containment (Section 11-1.2) RSCS Piers and Wharves Fuel Containment Systems (Section 5- 1.2) - Testing FPWCT

Fuel Pier/Wharf Containment (PWS Section 3) FPWC

Corrosion Control/Coatings Aboveground Piping and Equipment Coatings (Section 6-

10.1) AGPCT

Miscellaneous Miscellaneous Deactivated Components (Section 12-5) MDEAC Electrical/Lighting Lighting (Section 9-1.8) LIGHT

Electrical Equipment (Section 9-1.2) ELEQ Power Cables (Section 9-1.3) PWRCBL Motor Controls (Section 9-1.4) MTRCT Panelboards (Section 9-1.5) PNLB Electric Motors (Section 9-1.7) ELEMT Electronic Equipment (9-1.9) ELTREQ Card and Key Locks (Section 9-3) CKLK Power Grounding Systems (Section 9-1.6.1) PWRGS Static Grounding Systems (Section 9-1.6.2) STGS Cathodic Protection (Section 9-2.1) CP Lightning Surge Arresters (Section 9-2.2.1) LSAR Lightning Protection Systems (Section 9-4) LPTS Ground Verification System (Section 9-5) GRVS Electronic Overfill Protection Systems (Section 9-6) EOPS

Eyewash/Shower Emergency Eyewash/Showers (Section 11-3) EMEWSH

Fencing FENC

Gates GATE Pre-Filters (Section 3-6.1) PFVSL Filter Separators (Section 3-6.2) FLSP Haypack Filters (Section 3-6.3) HPKF Basket Strainers (Section 3-6.4) BSTR

Filter Separator Sump Heaters (Section 3-6.5) FSSH

Sidestream Filtration Systems (Section 8-9.11) SSFTS

Flame Arrestors (Section 8-9.5) FLMARR

Foam Fire Protection Systems (Section 8-9.15) FFPS Fire Protection Systems - Wet Pipe FPRS

Fuel Laboratories Ventilation Hoods (Section 11-4.1) VENTHD Pressure and Pressure/Vacuum Gauges (Section 6-7.1) PVGA Differential Pressure Gauges (Section 6-7.2) DPGA Mechanical Tape Gauges (Section 8-9.7) MTGA Mechanically Operated Tape Gauge (Section 8-9.8.1) MOTGA Magnetostrictive Probes (Section 8-9.8.2) MRPRB Servo Gauge (Section 8-9.8.3) SRVGA

Generators Back-Up Power Generators BGEN Steam Type Heating Coils (Section 8-9.16.1) STHC

Thermal Fluid Type Heating Coils (Section 8-9.16.2) TFTHC

Electric Rod Type Heating (Section 8-9.16.3) ERTH

Loading Fuel Hoses (Section 3-9.1) LDHS Offloading Fuel Hoses (Section 3-9.2) OLHS Aircraft Fueling Hoses (Section 4-7.5) ACFHS

Hydrazine Hydrazine Charging Units (Section 10-3) HDZCU Trouble Shoot TRBST API 510 Inspections API510 API 653 or STI Inspection API653 Coatings Condition Survey CCS Dispenser Nozzles (Section 7-2) DSNZ Dispenser Hoses (Section 7-3) DSHS Breakaways (Section 7-4) DSBW Swivels (Section 7-5) DSSW Hose Retriever (Section 7-6) HSRTV Dispenser Cabinet (Section 7-7) DSCB Dispenser Meters (Section 7-8) DSMTR Dispenser Filters (Section 7-9) DSFLR Dispenser Strainers (Section 7-10) DSSTR Ground Vehicle Fuel Piping (Section 7-11) GVFP

Hoses

Inspections

Fencing/ Gates

Filtration

Fire Suppression Equipment

Gauges

Heating Coils

Containment/Joints

Electrical/Power

Electrical/Protection

NOTE: If component acronym is not listed, the contractor shall request an acronym be established through the HNC Project Manager and Project Engineer via email. Contractors may utilize other means of tracking/labeling assets such as QR codes in addition to the required CUID however, tracking/labeling must correlate with the CUID. This CUID shall be the standard for all DLA capitalized equipment

Site Code-Facility #-Component Acronym-Sequential #

AAD-00063A-RCVL-0001

Alarms

Building

Example:

DLA Work Type Category UFC Section Reference Work Category (Revised per Change 1, 29 April 2021)

Component Acronym

NOTE: If component acronym is not listed, the contractor shall request an acronym be established through the HNC Project Manager and Project Engineer via email. Contractors may utilize other means of tracking/labeling assets such as QR codes in addition to the required CUID however, tracking/labeling must correlate with the CUID. This CUID shall be the standard for all DLA capitalized equipment

Site Code-Facility #-Component Acronym-Sequential #

AAD-00063A-RCVL-0001

Emergency Shutoff Valves (Shear Valves) (Section 7-12) ESHVL Dispenser Sumps (Section 7-13) DSSMP Transition Sumps (Section 7-14) TRSMP Remote Dispenser Pumps (Section 7-15.1) RDSP Self-Contained Dispenser Pumps (Section 7-15.2) SCDSP EFSO Systems (Section 7-16) EFSO Stage I Vapor Recovery (Section 7-17.1) SIVP Stage II Vapor Recovery (Section 7-17.2) SIIVP Vapor Burners (Section 7-17.3) VPBNR Point Sensor - Dry (Section 7-19.1.1) PSDRY Automatic Line Leak Detector (Section 7-19.1.2) ALLD Visual Monitoring (Section 7-20.1) VSLM Marine Receipt (Section 5-2) MRNRCP Marine Issue (Section 5-3) MRNISU Marine Loading Arms (Section 5-4) MRNLA Marine Transfer Hoses (Section 5-5.1) MBTHS Underwater Hoses (Section 5-5.2) UWHS Single Point Mooring Systems (Section 5-7.1) SPMSS Multi Point Mooring Systems (Section 5-7.2) MPMSS Submerged Piping Systems (Section 5-8) SMPS Boom Reels (Section 5-9) BMRL Liquefied Petroleum Tanks (Section 10-1.1) LPTANK Liquefied Petroleum Pipelines (Section 10-1.2) LPPIPE

Liquefied Petroleum Vapor Lines (Section 10-1.3) LPVPL

LPG Vaporizers (Section 10-1.4) LPGVPZ

Petroleum Gas Regulators (Section 10-1.5) PGREG

Liquefied Petroleum Gas Hoses (Section 10-1.6) LPGHS

Positive Displacement Meters (Section 3-7.1) PDMT Turbine Flow Meters (Section 3-7.2) TBFMT Orifice Flow Meters (Section 3-7.3) OFMT

Natural Disaster Natural Disaster CNG Piping (Section 10-2.1) NGPIPE

CNG Compressors (Section 10-2.2) NGCOMP

CNG Storage (Section 10-2.3) NGSTOR

CNG Dispensers (Section 10-2.4) NGDS

CNG Dispenser Hoses (Section 10-2.5) NGDSHS

Hydrant Adapters (Section 4-7.2) HADP

Fueling Nozzles (Section 4-7.3) FLNZ Other Fuel Additive Injectors (Section 3-11) FAIJ

Fixed Pantographs (Section 4-7.1.1) FXPNT Detachable Pantographs (Section 4-7.1.2) DTPNT On-Base Pipelines (Section 6-1.1) OBPL Non-DOT Regulated (Section 6-1.2.1) NDPL Aboveground Piping (Section 6-1.3) AGPL Double-Wall Piping (Section 6-1.4) DWPL Low Point Drains (Section 6-12.1) LPDN High Point Vents (Section 6-12.2) HPVT Sight Flow Indicators (Section 6-12.3) SFND Rope Sensor Systems (Section 6-13.1.1) RPSS Point Sensor - Dry (Section 6-13.1.2) PSDRY Visual Monitoring (Section 6-14.1) VSLM Pipe Penetrations (Section 8-10.6) PPEN Deactivated Petroleum Fuel Pipelines (Section 12-3) DEACPL Air Eliminator Tanks (Section 3-10.1) AELT Automatic Air Vents (Section 3-10.2) AAVT Surge Suppressors (Section 4-7.4) SRGSP Thermal and Pressure Relief Valves (Section 6-6.3) TPRVL Pressure Transmitters (Section 6-7.3) PRTR Differential Pressure Transmitters (Section 6-7.4) DPTR Flexible Ball Joints (Section 6-8) FBLJT Dial Thermometer (Section 6-9.1) DTHMR Emergency Vents (Section 8-9.4) EMGVT Centrifugal Pumps (Section 3-8.1) CENP Vertical Inline Pumps (Section 3-8.2) VILP

Vertical Turbine/Submerged Turbine Pumps (Section 3-8.3) VTSP

Sliding Vane Pumps (Section 3-8.5) SLVP Gear Pumps (Section 3-8.6) GERP Diaphragm Pumps (Section 3-8.7) DIAP

Internal Combustion Drives (Section 3-8.8) ICDR

Gearboxes (Section 3-8.9) GRBX

Deactivated Petroleum Fuel Pumps (Section 12-4) DEACP

Signage/Markings Signage and Markings (Section 2-7) SIGN Pumphouse/Filter Buildings (Section 11-2.1) PFBLDG Canopies (Section 11-2.2) CNPY Cranes and Hoists (Section 11-6) CRNHST Aboveground Field-Erected Tanks (Section 8-4) AGFET Geodesic Dome Roofs (Section 8-4.2) GEODR Foundations (Section 8-4.3) FOUND

Pressure/Temperature Control

Pump

Structures

Meter/ calibrations

Natural Gas

Nozzle

Pantograph

Piping

Issue/Receive - Ground

Issue/Receive - Marine

Liquefied Petroleum

Example:

DLA Work Type Category UFC Section Reference Work Category (Revised per Change 1, 29 April 2021)

Component Acronym

NOTE: If component acronym is not listed, the contractor shall request an acronym be established through the HNC Project Manager and Project Engineer via email. Contractors may utilize other means of tracking/labeling assets such as QR codes in addition to the required CUID however, tracking/labeling must correlate with the CUID. This CUID shall be the standard for all DLA capitalized equipment

Site Code-Facility #-Component Acronym-Sequential #

AAD-00063A-RCVL-0001

Aboveground Shop Fabricated Tanks (Section 8-5.1) AGSFP Self-Diking or Vaulted Tanks (Section 8-5.2) SDVT Rectangular Concrete-Encased Tanks (Section 8-5.3) RCET Single-Walled Underground Shop-Fabricated Tanks (Section

8-5.4.1) UGSSFT

Double-Walled Underground Shop-Fabricated Tanks (Section

8-5.4.2) UGDSFT

Underground Field-Constructed Tanks (Cut and Cover Tanks) (Section 8-6) UGFET

Tank Cleaning (Section 8-7) TCLEAN Aluminum Honeycomb Floating Pans (Section 8-9.1.1) AHFP Steel Floating Pans (Section 8-9.1.2) STLFP Pontoon Floating Pans (Section 8-9.1.3) PTNFP Floating Roofs (Section 8-9.1.4) FLTRF Floating Roof and Pan Pressure/Vacuum Vents (Section 8-

9.1.5) FPPVV

Floating Roof and Pan Legs (Section 8-9.1.6) FRPLG Secondary Tank Bottoms (Section 8-9.2) SNDTB Tank Pressure/Vacuum Vents (Section 8-9.3) TPVVT Product Saver Tanks (Section 8-9.10) PRDST Fill Ports (Section 8-9.12) FPRT Point Sensor - Dry (Section 8-9.13.1) PSDRY Point Sensor - Wet (Section 8-9.13.2) PSWET Point Sensor - Pressure/Vacuum (Section 8-9.13.3) PSPV

Visual Leak Detection (Section 8-9.13.4) VSLLD

Floating Suction Lines (Section 8-9.14) FLTSL Stilling Wells (Section 8-9.17) STGW Deactivated Petroleum Fuel Tanks (Section 12-2) DEACT

Testing Pressure Testing Isolation Valve Pits (Section 6-11.1) ISVLP Hydrant Fuel Pits (Section 6-11.2) HDFP High Point Vent Pits (Section 6-11.3) HPVP Low Point Drain Pits (Section 6-11.4) LPDP Lateral Control Pits (Section 6-11.5) LTCP General System Control Valves (Section 4-3.2.1) GSCVL Refuel Control Valves (Section 4-3.2.5) RCVL Pressure Relief Valves (Section 4-3.2.6) PRCVL Defuel Control Valve (Section 4-3.2.7) DFCVL Dual Rate-of-Flow Control Valves (Section 4-3.2.8) DRFCVL Combination Dual Rate-of-Flow Control and Solenoid Valves (Section 4-3.3.1) CFSCVL

Dual Pressure Relief, Solenoid Shutoff, and Check Valves (Section 4-3.3.2) DPSCVL

Non-Surge Check Valves (Section 4-4.2.1) NSCKVL Filter Separator Control Valves (Section 4-4.2.2) FSCVL Defuel/Flush Valves (Section 4-4.2.3) DFFCVL Issue Venturi (Section 4-4.2.4) ISVTR Return Venturi (Section 4-4.2.5) RTVTR Back Pressure Control Valves (Section 4-4.2.6) BPCVL Pressure Control Valves (Section 4-4.2.7) PCVL Hydrant Control Valves (Section 4-4.2.8) HCVL Emergency Shut-off Valves (Section 4-4.2.9) ESOVL Pantograph Control Valves (Section 4-5.2.12) PTCVL Pantograph Pressure Control Valves (Section 4-5.2.13) PTPCVL Overfill Valve for Product Recovery Tanks (Section 4-8.1) OVLPRT Plug Valves - Lubricated (Section 6-6.2.1) PLVL Plug Valves - Non-lubricated (Section 6-6.2.2) NPLVL Gate Valves (Section 6-6.2.3) GTVL Ball Valves (Section 6-6.2.4) BLVL Double Block and Bleed Valves (Section 6-6.2.5) DBBVL Butterfly Valves (Section 6-6.2.6) BFVL Globe Valves (Section 6-6.2.7) GLVL Check Valves (Section 6-6.2.8) CKVL Line Blanks, Ring Spacers, and Spectacle Blinds (Section 6-

6.2.9) BLIND

Manual Valve Gear Operators (Section 6-6.2.10) MVLGO Fire Valves (Section 6-6.4.1) FRVL Fusible Link Butterfly Valves (Section 6-6.4.2) FLBFVL

Truck Fill Valves (Section 6-6.5.1) TFVL

Motor Operators (Section 6-6.6) MTROP

External High Level Shutoff Valves (HLSO) (Section 8-9.6.1) EHLSVL

Internal HLSO Valves (Section 8-9.6.2) IHLSVL Waste Oil/Water Separators (Section 11-5) OWS

Valves

Tank

Underground Pits

Component Acronym

File details come from the government source that posted it. Updated .