RFI-50 - ES103 - ENLARGED - ELECTRICAL SITE PLAN.pdf
PDF 531 KB Posted
- Solicitation number
- W912DS26BA032
About this file
This is an electrical site plan drawing for a power generation microgrid project at Joint Base McGuire-Dix-Lakehurst, New Jersey. The plan, dated July 2026 and revised for bidder inquiries in September 2026, depicts the layout and coordination of major electrical infrastructure components including two 500KW/625KVA natural gas generator sets operating at 480V, three-phase; one 500KW battery energy storage system (BESS) enclosure; a new 2300KW/2500KVA utility transformer rated 34.5KV to 480Y/277V; pole-mounted light fixtures with direct-buried PVC conduit; and surface-mounted GFI duplex receptacles. The drawing is prepared by Burns and McDonnell (Kansas City, MO) for the U.S. Army Corps of Engineers, New York District, and includes coordination notes referencing structural, civil, and additional electrical drawings in the EP and ES series.
The site plan emphasizes preliminary coordination with requirements to finalize equipment dimensions, concrete pad specifications, and spacing based on approved equipment submissions and final BESS configuration. Special attention is directed to environmental water line protection, with note that any damage to existing water infrastructure must be repaired immediately at no additional cost to the government. The drawing indicates minimum clearances of 11'-6" for specified areas and references a microgrid controller (JACE) for system management. This RTA (Ready to Award) submittal serves as a reference document for contract bidders and includes standard sheet keynotes, abbreviations, and phasing notes documented in companion drawings E-001, E-002, and the CS/CU civil series.
View the file
Other files
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LOCLOCLOCLOCLOCLOC
LOC
LOC
LOC
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
CLOCLOCLOCLOCLOC
LO
CLOC
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
CX
X
X
X
X
X
X X
X
X
X
X
X
X
X
X X
X X
XXXXXXXXXXXXXXXXXX
X
X
X
X
X
X
X X
X X
X X
X
X
X
X
X
X
X
X X X X X X X X
G
G
G
N G
-1
BE
SS
-1
N G
-2
ES501
A11
ES502
E1
UE
U E
U E
UE
E
E E E E E E E E E E E E E E
U E E
BE
SS
-2
BE
SS
-3
S1
MPC-1-3
S1
MPC-1-3
11'-6"
MIN
11'-6"
MIN
6'-0"
MIN
HH-1
HH-2HH-3
HH-4
S1
MPC-1-3
S1
MPC-1-3
S1
MPC-1-3
S1
MPC-1-3
S1
MPC-1-3
TYP.
S1
MPC-1-3
LOC
LO
CLOC
LOC
LOC
LO
C
LOC
LO
C
LOC LOC
LOC
LO
C
LO
C
LOC
LOC
W-QLD
X
X X
XX
ATS-1
T-OL
T-3
DP3
MEP
DPL
FC
RP400
T-2 T-2
SPD
SWGR-1
SWGR-1
JACE
CONTROLLER
SCALE: 1" = 20'
ENLARGED - ELECTRICAL SITE PLANA1
1. 500KW/625KVA, 480V, 3 PHASE, NATURAL GAS GENERATOR
SET, NG-1.
2. 500KW/625KVA, 480V, 3 PHASE, NATURAL GAS GENERATOR
SET, NG-2.
3. 500KW BATTERY ENERGY STORAGE SYSTEM ENCLOSURE.
4. PROVIDE 'S1' POLE MOUNTED LIGHT FIXTURE IN 1" DIRECT
BURIED SCHEDULE 40 PVC CONDUIT. REFER TO LIGHT POLE
INSTALLATION DETAIL, A5/ES504. REFER TO DRAWING EP601
FOR ADDITIONAL CIRCUITING INFORMATION.
5. PROVIDE SURFACE MOUNTED, WPIU, GFI DUPLEX,
CIRCUITED FROM MPC-1. REFER TO DRAWING EP601 FOR
ADDITIONAL CIRCUITING INFORMATION. TYPICAL OF ALL
RECEPTACLES ON PLAN.
6. PROVIDE NEW 2300KW/2500KVA, 34.5KV:480Y/277V UTILITY
TRANSFORMER. REFER TO EP700 SERIES FOR ADDITIONAL
INFORMATION.
PLAN
NORTH
20' 40'0
1. REFER TO DRAWING E-001 AND E-002 FOR LEGENDS,
NOTES, ABBREVIATIONS AND PHASING NOTES.
2. REFER TO SITE/CIVIL CU AND CS SERIES DRAWINGS FOR
ADDITIONAL INFORMATION.
3. REFER TO STRUCTURAL DRAWINGS FOR ADDITIONAL
INFORMATION.
4. BESS CONTAINERS, GENERATORS, AND MICROGRID
CONTROLLER ARE SHOWN FOR PRELIMINARY SITE
COORDINATION. COORDINATE FINAL EQUIPMENT
DIMENSIONS, CONCRETE PAD DIMENSIONS, AND
EQUIPMENT SPACING BASED ON APPROVED EQUIPMENT.
COORDINATE WITH FINAL BESS CONFIGURATION FOR FINAL
LAYOUT COORDINATION.
5. TAKE SPECIAL CARE WITH ANY WORK IN VICINITY OF
ENVIRONMENTAL WATER LINE. ANY DAMAGE TO EXISTING
WATER LINE MUST BE REPAIRED IMMEDIATELY AT NO
ADDITIONAL COST TO GOVERNMENT.
GENERAL SHEET NOTES
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S N
EW
Y
O R
K D
IS
TR
IC
T
F
ED
ER
AL
P
LA
ZA
, R M
6-
N
EW
Y O
R K, N Y
8-
BU
R
N S
AN
D
M cD
O N
N
EL
L
W
AR
D
P
AR
KW
AY
K
AN
SA
S C
IT
Y
M O
, 6
US Army Corps of Engineers ®
AN
SI
D
C
AD
D C
O D
E:
-JU
LY
FI
LE
N
AM
E:
ES
0.
dw g
R
TA
S U
BM
IT
TA
L
KEY PLAN
PO
W
ER
G
EN
ER
AT
IO
N W
IT
H
M
IC
R O
G R
ID
JO
IN
T-
BA
SE
M
C G
U
IR
E- D
IX
-L
AK
EH
U R
ST
, N
J
1 0 R
EV
IS
ED
F
O R
B
ID
D
ER
IN
Q
U
IR
IE
S
R
TA
S U
BM
IT
TA
L
E.
P
U
TN
AM
A.
B
AR
R
O N
A.
C
AR
AB
IL
LO
C . P
LU
M
M
ER
EN
LA
R G
ED
EL
EC
TR
IC
AL
S
IT
E
PL
AN
ES103
SHEET KEYNOTES
TYP.
ES501
A1
ES501
H1
HH-5
ES402
A4
ES501
H11
ES502
A1
SEE SHEET ES102 FOR CONTINUATION
JU
LY
SE
PT
AutoCAD SHX Text
TELEPHONE HAND HOLE
AutoCAD SHX Text
ELECTRIC HAND HOLE
AutoCAD SHX Text
ELECTRIC HAND HOLE
AutoCAD SHX Text
TELEPHONE HAND HOLE
AutoCAD SHX Text
QLD WATER
AutoCAD SHX Text
TELEPHONE HAND HOLE
AutoCAD SHX Text
ELECTRIC HAND HOLE
AutoCAD SHX Text
ELECTRIC HAND HOLE
AutoCAD SHX Text
TELEPHONE HAND HOLE
AutoCAD SHX Text
TELEPHONE MANHOLE RIM: 73.77
AutoCAD SHX Text
EOWL
AutoCAD SHX Text
EOI
AutoCAD SHX Text
EOI
AutoCAD SHX Text
EOI
AutoCAD SHX Text
EOI
AutoCAD SHX Text
QLD WATER
AutoCAD SHX Text
QLD WATER
AutoCAD SHX Text
QLD WATER
AutoCAD SHX Text
QLD WATER
AutoCAD SHX Text
QLD WATER
AutoCAD SHX Text
EOWL
AutoCAD SHX Text
EOWL
AutoCAD SHX Text
QLD WATER
AutoCAD SHX Text
QLD WATER
AutoCAD SHX Text
QLD WATER
AutoCAD SHX Text
2-2" PVC CRISERS
AutoCAD SHX Text
BXC
AutoCAD SHX Text
6" PERFORATED PVC GROUNDWATER TREATMENT (GIS)
AutoCAD SHX Text
6" PERFORATED PVC GROUNDWATER TREATMENT (GIS)
AutoCAD SHX Text
6" PERFORATED PVC GROUNDWATER TREATMENT (GIS)
AutoCAD SHX Text
6" PERFORATED PVC GROUNDWATER TREATMENT (GIS)
AutoCAD SHX Text
6" PERFORATED PVC GROUNDWATER TREATMENT (GIS)
AutoCAD SHX Text
6" PERFORATED PVC GROUNDWATER TREATMENT (GIS)
AutoCAD SHX Text
6" PERFORATED PVC GROUNDWATER TREATMENT (GIS)
AutoCAD SHX Text
6" PERFORATED PVC GROUNDWATER TREATMENT (GIS)
AutoCAD SHX Text
6" PERFORATED PVC GROUNDWATER TREATMENT (GIS)
AutoCAD SHX Text
6" PERFORATED PVC GROUNDWATER TREATMENT (GIS)
File details come from the government source that posted it. Updated .