RFI-47 - ES503 - ELECTRICAL SITE DETAILS.pdf

PDF 1023 KB Posted

Attached to
Construction of the Power Generation with Microgrid at Joint Base McGuire-Dix-Lakehurst (JBMDL), New Hanover, NJ
Solicitation number
W912DS26BA032
Issued by

About this file

This document is an electrical site details drawing sheet for a Power Generation with Microgrid project at Joint Base McGuire-Dix-Lakehurst, New Jersey, prepared by the U.S. Army Corps of Engineers, New York District.

The drawing (Sheet ES503, Revision 01, issued September 2026) provides technical specifications and installation details for electrical infrastructure components including electrical maintenance holes, handholes, and light pole bases. Key details include: electrical maintenance hole frame and cover designs with dimensions ranging from 24"L x 18"W to 72"L x 48"W with corresponding depths of 18" to 36"; handhole schedules specifying 12 different configurations with varying dimensions and knockouts; reinforcing requirements for concrete construction with minimum No. 4 round deformed bars at 12-inch centers on walls and floors, 4-inch centers on tops, and diagonal reinforcement at 45-degree angles; a typical light pole base detail featuring a 17-foot high square tapered aluminum pole with dark bronze finish, Type S1 pole-mounted light fixture (4000K, 6,000 lumens, 80CRI, 120V, 45W), ground rod installation, and photocell sensor; and electrical conduit penetration details through existing brick cavity walls with CMU backup walls including sealant and mineral wool insulation requirements. The document references specification sections 03 30 00 (concrete foundation), 07 92 00 (sealants), 09 90 00 (painting), and drawing EP601 (conduit and wire sizing).

View the file

Other files

File Type Posted
Bid Abstract Form Power Generation Microgrid Revised Final.pdf PDF
RFI-74 - EP701 - PARTIAL ONE-LINE DIAGRAM A - NEW WORK.pdf PDF
RFI-32 - M-702 - MECHANICAL CONTROLS ARCHITECTURE.pdf PDF
RFI-11 - M-501 - MECHANICAL DETAILS.pdf PDF
RFI-21 - SPEC 26 08 00.pdf PDF
RFI log for posting 9.23.26.xlsx XLSX spreadsheet
AF Meter Data Management Plan 20250610.pdf PDF
RFI-50 - ES103 - ENLARGED - ELECTRICAL SITE PLAN.pdf PDF
RFI-08 - SPEC 09 90 00.pdf PDF
RFI-22 - CS502 - SITE DETAILS - 2.pdf PDF
RFI-90 - SPEC 26 31 00.pdf PDF
RFI-16 - SPEC 32 31 13.pdf PDF
RFI-17 - CS112 - SITE PLAN - AREA 2.pdf PDF
RFI-62 - SPEC 31 00 00.pdf PDF
01 45 35 - Attachment - Schedule_of_Special_Inspections.pdf PDF
Solicitation Amendment W912DS26BA0320001 SF 30.pdf.pdf PDF
RFI-75 - SPEC 26 12 19.pdf PDF
RFI-49 - ES102 - ENLARGED - ELECTRICAL SITE PLAN.pdf PDF
RFI-02 - SPEC 26 37 13.pdf PDF
RFI-63 - SPEC 32 11 26.pdf PDF
2026.09.03_Site Visit_Sign in for Power Gen_Lakehurst.pdf PDF
2026.09.03_Site Visit_Sign in for Power Gen_Lakehurst.pdf PDF
Power Gen w. microgrid bidder walkthrough packet.pdf PDF
A.03.09 Drawings - 100%.pdf PDF
Power Generation with Microgrid - Specifications - RTA_rev1.pdf PDF
Solicitation - W912DS26BA032.pdf PDF
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GRADE

POWER CABLE RACKS

SLOPE

1/4" = 1'-0"

12"

GRAVEL (2'-0" DIA)

SUMP

#1/0 AWG GROUND

CONDUCTOR

GROUND ROD

1. BARS WILL BE A MINIMUM OF NO. 4 ROUND DEFORMED.

2. WALLS AND FLOOR WILL HAVE BARS AT 12-INCHES MINIMUM ON CENTERS WITH A

MINIMUM 12-INCH HOOK AT CORNERS AND INTERSECTIONS.

3. THE TOP WILL HAVE BARS INSTALLED AT 4-INCHES ON CENTER MINIMUM

LATERALLY AND LONGITUDINALLY AS APPROPRIATE, EXCEPT AT OPENINGS -

ALSO PROVIDE AN ADDITIONAL BAR AT A 2-INCH SPACING AND TWO DIAGONAL

BARS EACH WAY AT 45-DEGREES AND LOCATED ABOVE LATERAL OR

LONGITUDINAL BARS.

MINIMUM REINFORCING

CONSTRUCTION REQUIREMENTS

PULLING IRONS

ELECTRIC BLOCK LETTERS, 2"

HIGH x 1 1/4" WIDE, WITH 3/8" STROKE

(TYP).

COVER HANDLE

2'-7 3/4"

2'-6"

3'-5"

4'-1"

30"

17.25"

9 GA WELDED

WIRE FRAME

3" KNOCKOUTS

2"

1.5"

HANDHOLE SCHEDULE

HH#

HH-1

HH-2

HH-3

HH-4

HH-5

HH-6

HH-7

HH-8

HH-9

HH-10

HH-11

DIMENSIONS

72"L x 48"W x 36"D

60"L x 48"W x 36"D

48"L x36"W x 36"D

60"L x 48"W x 36"D

48"L x36"W x 36"D

48"L x36"W x 36"D

48"L x 36"W x 36"D

36"L x 18"W x 18"D

36"L x24"W x 24"D

24"L x 18"W x 18"D

36"L x 18"W x18"D

HH-12 36"L x24"W x 24"D

PVC COATED GRS. SEE NOTE 1 (TYP)

PVC TO GRS ADAPTER (TYP)

FINISHED GRADE LEVEL

PVC CONDUIT. SEE NOTE 1 (TYP)

24"

NOTES:

1. REFER TO EP601 FOR CONDUIT AND WIRE

SIZE.

2. PROVIDE VIBRATION ISOLATION PAD AT

LIGHTING POLE BASE.

3. REFER TO SPECIFICATION SECTION 03 30 00

FOR CONCRETE FOUNDATION INFORMATION

EXOTHERMIC

WELDED

CONNECTION

TYPE S1 POLE MOUNTED LIGHT FIXTURE,

WITH SYMMETRICAL TYPE 2 DISTRIBUTION

AND DARK BRONZE FINISH.

4000K, 6,000 LUMENS, 80CRI, 120V, 1P, 45W

17'-0" HIGH, SQUARE, TAPERED

ALUMINUM POLE WITH DARK BRONZE

FINISH.

BASE PLATE AND ANCHOR BOLTS

FURNISHED BY POLE MANUFACTURER

STUB CONDUIT(S) UP 8" ABOVE

BASE AND BUSH END(S) (TYP)

BOND ROD TO

GROUND LUG WITH #6

AWG CONDUCTOR

10'x3/4" DIA.

GROUND ROD

1"

YOKE MOUNTED

PHOTOCELL SENSOR

36"

(8) #8 VERTICAL

BARS (TYP)

#3 TIES AT 12" O.C.

(TOP 3 TIES AT 3" O.C.)

#3 TIES AT 12" O.C.

AIR TERMINAL

#6 AWG GROUND

CONDUCTOR

COMPRESSIBLE GASKET

EXTERIOR INTERIOR

ELECTRICAL CONDUIT

CONDUIT SLEEVE

CONTINUOUS BEAD OF

SEALANT AT PERIMETER

(REF. SPEC SECTION 07 92 00)

EXISTING EXTERIOR BRICK CAVITY WALL

ELECTRICAL CONDUIT PENETRATING EXISTING

BRICK CAVITY WALL WITH CMU BACKUP WALL

CONTINUOUS BEAD OF

SEALANT AT PERIMETER

(REF. SPEC SECTION 07 92 00)

REF. SPEC SECTION 09 90 00

FOR PAINTING OF CONDUIT

(EXTERIOR ONLY)

M

IN

PACK VOIDS AROUND

OPENING WITH

MINERAL WOOL

INSULATION

1"

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

B U

R N

S A

N D

M c D

O N

N E

L L

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

A L T

E R

N A

T E

I N

F O

F

IL

E N

A M

E

US Army Corps of Engineers ®

J O

IN

T

-B A

S E

M C

G U

IR

E

-D

IX

-L A

K E

H U

R S

T N

J P

O W

E R

G E

N E

R A

T

IO

N W

IT

H

M

IC

R O

G R

ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S N

E W

Y O

R K

D

IS

T R

IC

T

F

E D

E R

A L P

L A

Z A

R

M

-3

N E

W Y

O R

K N

Y

-0

S E

P T

R E

V

ES503

E L E

C T

R

IC

A L S

IT

E

D E

T A

IL

S

A B

A R

R O

N

J M

A Y

R A

N T

E P

U T

N A

M

C P

L U

M M

E R

W D

S D

NTSSCALE:

A1

ELECTRICAL MAINTENANCE HOLE

NTSSCALE:

J1

ELECTRICAL MAINTENANCE HOLE FRAME AND COVER

NTSSCALE:

A7

ELECTRICAL HANDHOLE

NTSSCALE:

A12

TYPICAL LIGHT POLE BASE DETAIL

NTSSCALE:

J7

TYPICAL BRICK CAVITY WALL PENETERATION DETAIL

R

T A

S U

B M

IT

T

A L

J U

L Y

R

E V

IS

ED

F O

R B

ID

D

ER

IN

Q U

IR

IE

S

S

EP

T ajbarron Text Box

File details come from the government source that posted it. Updated .