This document is a set of technical construction drawings and specifications for temporary and permanent security fencing systems prepared by the US Army Corps of Engineers New York District for Joint Base McGuire-Dix-Lakehurst, New Jersey.

The drawings detail four primary fence configurations: Temporary Fence Type 1 (pavement areas) utilizing rubber tires filled with concrete as ballast weighted to specifications; Temporary Fence Type 2 (pedestrian areas) featuring ground-driven posts without concrete footings; a Temporary 20-foot Wide Gate design; a 12-foot Double Swing Gate; and a permanent Chain-Link Security Fence with concrete footings. All fence designs incorporate 2-inch chain-link fabric at 7 feet height, tension wires, truss rods, braces, and black obscuring fabric attached at top and bottom per manufacturer recommendations. Gates include plunger rod catches and latches to accommodate padlocks. Temporary Type 1 fencing explicitly prohibits use adjacent to pedestrian areas. Concrete footings are specified at 3000 PSI minimum. The document is dated July 2026 as an RTA (Readiness Training Assessment) submittal for a Power Generation with Microgrid project, with a revision issued September 2026 for bidder inquiries. Sheet identifier is CS502, and drawings are not to scale (NTS). Fence posts must be located to avoid conflict with underground piping.

View the file

Other files

File Type Posted
Bid Abstract Form Power Generation Microgrid Revised Final.pdf PDF
RFI-17 - CS112 - SITE PLAN - AREA 2.pdf PDF
RFI-62 - SPEC 31 00 00.pdf PDF
01 45 35 - Attachment - Schedule_of_Special_Inspections.pdf PDF
Solicitation Amendment W912DS26BA0320001 SF 30.pdf.pdf PDF
RFI-75 - SPEC 26 12 19.pdf PDF
RFI-47 - ES503 - ELECTRICAL SITE DETAILS.pdf PDF
RFI-74 - EP701 - PARTIAL ONE-LINE DIAGRAM A - NEW WORK.pdf PDF
RFI-32 - M-702 - MECHANICAL CONTROLS ARCHITECTURE.pdf PDF
RFI-11 - M-501 - MECHANICAL DETAILS.pdf PDF
RFI-21 - SPEC 26 08 00.pdf PDF
RFI log for posting 9.23.26.xlsx XLSX spreadsheet
AF Meter Data Management Plan 20250610.pdf PDF
RFI-50 - ES103 - ENLARGED - ELECTRICAL SITE PLAN.pdf PDF
RFI-08 - SPEC 09 90 00.pdf PDF
RFI-90 - SPEC 26 31 00.pdf PDF
RFI-16 - SPEC 32 31 13.pdf PDF
RFI-49 - ES102 - ENLARGED - ELECTRICAL SITE PLAN.pdf PDF
RFI-02 - SPEC 26 37 13.pdf PDF
RFI-63 - SPEC 32 11 26.pdf PDF
2026.09.03_Site Visit_Sign in for Power Gen_Lakehurst.pdf PDF
2026.09.03_Site Visit_Sign in for Power Gen_Lakehurst.pdf PDF
Power Gen w. microgrid bidder walkthrough packet.pdf PDF
Power Generation with Microgrid - Specifications - RTA_rev1.pdf PDF
A.03.09 Drawings - 100%.pdf PDF
Solicitation - W912DS26BA032.pdf PDF
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SCALE: NTS

CHAIN-LINK SECURITY FENCEA14

10'-0" (MAXIMUM)END BAY

MULTIPLES OF

10'-0" MAXIMUM

TOP

RAIL

ANGLE OR

CORNER POST

FINISH

GRADE

TRUSS ROD

CHAIN LINK FABRIC

2" 7'

-0

BOTTOM

RAIL

3' -0

6"

10"

(MIN)

CONCRETE

FOOTING (TYP)

12'-0"

7' -0

2"

6" 3'

-0

10"

9"

MIN

MIN

FINISH GRADE

PLUNGER ROD CATCH

GATE POST

GATE FRAME GATE POST

TRUSS

RODS

CHAIN

LINK

FABRIC

BRACE

TRUSS

RODS

CHAIN

LINK

FABRIC

LATCH TO

ACCOMMODATE

PADLOCK

BRACE

M

IN

CONCRETE

FOOTING (TYP)

SCALE: NTS

12' DOUBLE SWING GATEA8

SCALE N.T.S.

TEMPORARY FENCE - TYPE 1

(PAVEMENT AREAS)

H1 SCALE N.T.S.

TEMPORARY 20' WIDE GATEH8

VARIES (SEE PLANS)

6' -0

2" M

AX

6" 3'

-0

12"

MIN

10'-0" (MAXIMUM)END BAY

MULTIPLES OF 10'-0"

MAXIMUM

6' -0

NOTES:

1. RUBBER TIRE FILLED WITH CONCRETE SHALL NOT BE USED ADJACENT TO AREAS USED BY

PEDESTRIANS. AT LOCATIONS NEXT TO PEDESTRIAN AREAS USE TEMPORARY FENCE - TYPE 2.

2. SAND / WEIGHTING DOWN AS NEEDED.

3. FENCE SHALL INCLUDE BLACK OBSCURING FABRIC, ATTACHED AT TOP AND BOTTOM AS

RECOMMENDED BY MANUFACTURER.

FINISH GRADE

GATE POST GATE FRAME

GATE POST

TRUSS

RODS

CHAIN LINK FABRIC

BRACE

TRUSS

RODS

BRACE

CONCRETE

FOOTING (TYP)

(3000 PSI MIN)

TENSION WIRE

CORNER POST CHAIN

LINK FABRIC

BRACE

TRUSS ROD

LINE POST

RUBBER TIRE FILLED

WITH CONCRETE (TYPICAL) TENSION WIRE

OUTRIGGER WELDED TO

GATE POST (TYP)

LATCH TO

ACCOMMODATE

PADLOCK

TENSION WIRE

CHAIN LINK FABRIC

SCALE N.T.S.

TEMPORARY FENCE - TYPE 2H15

10'-0" (MAXIMUM)END BAY

MULTIPLES OF 10'-0"

MAXIMUM

6' -0

TENSION WIRE

CORNER POST CHAIN

LINK FABRIC

BRACE

TRUSS ROD

LINE POST

POST DRIVEN

INTO GROUND (TYPICAL)

TENSION WIRE

3' -0

" M

IN

PLUNGER ROD CATCH

NOTES:

1. FENCE SHALL INCLUDE BLACK OBSCURING FABRIC, ATTACHED AT TOP

AND BOTTOM AS RECOMMENDED BY MANUFACTURER.NOTES:

1. FENCE SHALL INCLUDE BLACK OBSCURING FABRIC, ATTACHED AT TOP

AND BOTTOM AS RECOMMENDED BY MANUFACTURER.

CS502

NOTES:

1. LOCATE FENCE POSTS TO AVOID CONFLICT WITH UNDERGROUND PIPING

AS NECESSARY.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SU

BM

IT

TE

D B

Y:

C H

EC

KE

D B

Y:

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

IS

SU

E D

AT

E:

SI

ZE

M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S N

EW

Y

O R

K D

IS

TR

IC

T

F

ED

ER

AL

P

LA

ZA

, R M

6-

N

EW

Y O

R K, N Y

8-

BU

R

N S

AN

D

M cD

O N

N

EL

L

W

AR

D

P

AR

KW

AY

K

AN

SA

S C

IT

Y

M O

, 6

US Army Corps of Engineers ®

AN

SI

D

C

AD

D C

O D

E:

-JU

LY

FI

LE

N

AM

E:

-C S5

.d w g

R

TA

S U

BM

IT

TA

L

PO

W

ER

G

EN

ER

AT

IO

N W

IT

H

M

IC

R O

G R

ID

JO

IN

T-

BA

SE

M

C G

U

IR

E- D

IX

-L

AK

EH

U R

ST

, N

J

R

TA

S

U

BM

IT

TA

L

JU

LY

L.

M

O N

ZO

N

R . T

AD

D

EO

K.

W

AR

R

EN

D

ER

CS502

SI

TE

D

ET

AI

LS

R

EV

IS

ED

F

O R

B

ID

D

ER

IN

Q

U

IR

IE

S

SE

PT

File details come from the government source that posted it. Updated .