RFI-32 - M-702 - MECHANICAL CONTROLS ARCHITECTURE.pdf

PDF 53 KB Posted

Attached to
Construction of the Power Generation with Microgrid at Joint Base McGuire-Dix-Lakehurst (JBMDL), New Hanover, NJ
Solicitation number
W912DS26BA032
Issued by

About this file

This is a mechanical controls architecture drawing for a Power Generation with Microgrid project at Joint Base McGuire-Dix-Lakehurst, New Jersey, prepared by the U.S. Army Corps of Engineers, New York District.

The drawing depicts a schematic system architecture for integrating DDC (Direct Digital Control) systems with existing facility infrastructure. Key components include the existing EMCS (Energy Management Control System), AMRS (Automated Meter Reading System), managed Ethernet switches located in building B678's main electrical room, a manufacturer-provided microgrid controller, electric and gas utility meters, and JACE controllers for network communication via Niagara protocol. The contractor is responsible for providing a complete and functional system compliant with specification sections 25 10 10, including final architectural details, device selection, network bindings, all power wiring and components downstream of existing 120-volt single-phase junction boxes, verification of adequate junction box quantity and location, front-end configuration changes to existing servers and workstations, and final network connections to existing switches unless otherwise directed. The gas meter shall be connected to the electric meter on a separate meter reading system with compatibility as described in Division 26 specifications. The microgrid and battery energy storage systems must be capable of integrating into the network but are not directly governed by all section 25 10 10 requirements. The drawing was initially issued July 2026 and revised for bidder inquiries in September 2026.

View the file

Other files

File Type Posted
Bid Abstract Form Power Generation Microgrid Revised Final.pdf PDF
RFI-17 - CS112 - SITE PLAN - AREA 2.pdf PDF
RFI-62 - SPEC 31 00 00.pdf PDF
01 45 35 - Attachment - Schedule_of_Special_Inspections.pdf PDF
Solicitation Amendment W912DS26BA0320001 SF 30.pdf.pdf PDF
RFI-75 - SPEC 26 12 19.pdf PDF
RFI-47 - ES503 - ELECTRICAL SITE DETAILS.pdf PDF
RFI-74 - EP701 - PARTIAL ONE-LINE DIAGRAM A - NEW WORK.pdf PDF
RFI-11 - M-501 - MECHANICAL DETAILS.pdf PDF
RFI-21 - SPEC 26 08 00.pdf PDF
RFI log for posting 9.23.26.xlsx XLSX spreadsheet
AF Meter Data Management Plan 20250610.pdf PDF
RFI-50 - ES103 - ENLARGED - ELECTRICAL SITE PLAN.pdf PDF
RFI-08 - SPEC 09 90 00.pdf PDF
RFI-22 - CS502 - SITE DETAILS - 2.pdf PDF
RFI-90 - SPEC 26 31 00.pdf PDF
RFI-16 - SPEC 32 31 13.pdf PDF
RFI-49 - ES102 - ENLARGED - ELECTRICAL SITE PLAN.pdf PDF
RFI-02 - SPEC 26 37 13.pdf PDF
RFI-63 - SPEC 32 11 26.pdf PDF
2026.09.03_Site Visit_Sign in for Power Gen_Lakehurst.pdf PDF
2026.09.03_Site Visit_Sign in for Power Gen_Lakehurst.pdf PDF
Power Gen w. microgrid bidder walkthrough packet.pdf PDF
Power Generation with Microgrid - Specifications - RTA_rev1.pdf PDF
A.03.09 Drawings - 100%.pdf PDF
Solicitation - W912DS26BA032.pdf PDF
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GAS

UTILITY METER

REFER TO CIVIL

DRAWINGS FOR

LOCATION.

MFR PROVIDED MICROGRID

CONTROLLER. REFER TO

ELECTRICAL DRAWINGS FOR

LOCATION.

(INCLUDES GENERATORS)

EXISTING

EMCS

ELECTRIC

UTILITY METER

LOCATED IN

THE EXISTING

BUILDING MAIN

ELECTRICAL

ROOM IN B678.

PROVIDE JACE AS REQUIRED TO

COMMUNICATE WITH THE EXISTING

NETWORK VIA NIAGARA JACE

CONTROLLER IN THE EXISTING BUILDING

MAIN ELECTRICAL ROOM IN B678.

FPOC

FPOC

MANAGED ETHERNET

SWITCH (EXISTING) IN THE

EXISTING BUILDING MAIN

ELECTRICAL ROOM IN B678.

EXISTING

AMRS

MONITORING COMMUNICATION ONLY

MANAGED ETHERNET

SWITCH (EXISTING) IN

THE EXISTING BUILDING

MAIN ELECTRICAL

ROOM IN B678.

NOTES:

SYSTEM ARCHITECTURE IS SCHEMATIC.

CONTRACTOR SHALL PROVIDE ADDITIONAL

DEVICES AS REQUIRED FOR A COMPLETE AND

FUNCTIONAL SYSTEM IN COMPLIANCE WITH

SPECIFICATION SECTIONS 25 10 10.

CONTRACTOR IS RESPONSIBLE FOR SELECTING

FINAL DETAILS OF THE ARCHITECTURE AND

ENSURING THAT THE SYSTEM (DEVICES,

NETWORK BINDINGS, AND NETWORK

ARCHITECTURE) MEETS THE BANDWIDTH AND

COMMUNICATION SPEED REQUIREMENTS

SPECIFIED IN SECTIONS 25 10 10.

120 VOLT SINGLE PHASE POWER CONNECTION

JUNCTION BOXES ARE EXISTING FOR USE TO

POWER DDC SYSTEM COMPONENTS IN THE

EXISTING MAIN ELECTRICAL ROOM IN B678. THE

DDC CONTROLS CONTRACTOR IS RESPONSIBLE

FOR ALL POWER WIRING AND COMPONENTS

DOWNSTREAM OF THESE JUNCTION BOXES AND

VERIFYING THE QUANTITY AND LOCATION OF THE

JUNCTION BOXES IS ADEQUATE. ADDITIONAL

POWER CONNECTIONS ARE THE RESPONSIBILITY

OF THE DDC CONTROLS CONTRACTOR.

THE GAS METER SHALL BE CONNECTED TO THE

ELECTRIC METER AND MONITORED ON A

SEPARATE METER READING SYSTEM. REFER TO

DIV. 23 SPECIFICATIONS FOR GAS METER

REQUIREMENTS. PROVIDE METERS COMPATIBLE

WITH ELECTRIC METER AS DESCRIBED IN DIV. 26.

CONTRACTOR TO PROVIDE FRON'T END

CONFIGURATION CHANGES TO EXISTING

SEVER/WORKSTATION/LAPTOP.

CONTRACTOR TO PROVIDE FINAL CONNECTIONS

TO EXISTING SWITCHES UNLESS OTHERWISE

DIRECTED BY THE BASE.

CONTRACTOR TO PROVIDE NETWORK TO MEET

REQUIREMENTS OUTLINED IN SPECIFICATION

SECTIONS 25 10 10. THE MICROGRID AND BESS

SYSTEMS SHALL BE CAPABLE OF INTEGRATING

INTO THE NETWORK BUT ARE NOT DIRECTLY

GOVERNED BY ALL 25 10 10 REQUIREMENTS.

1.

2.

3.

4.

5.

6.

7.

FPOC

KEY:

FACILITY POINT OF CONNECTION ROUTER

NODE / CONTROLLER

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

B U

R N

S A

N D

M c D

O N

N E

L L

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

A L T

E R

N A

T E

I N

F O

F

IL

E N

A M

E

US Army Corps of Engineers ®

J O

IN

T

-B A

S E

M C

G U

IR

E

-D

IX

-L A

K E

H U

R S

T N

J P

O W

E R

G E

N E

R A

T

IO

N W

IT

H

M

IC

R O

G R

ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S N

E W

Y O

R K

D

IS

T R

IC

T

F

E D

E R

A L P

L A

Z A

R

M

-3

N E

W Y

O R

K N

Y

-0

R E

V

IS

E D

F O

R B

ID

D

E R

I N

Q U

IR

IE

S

M-702

M E

C H

A N

IC

A

L C

O N

T R

O L S

A R

C H

IT

E

C T

U R

E

C U

T T

M C

R A

IN

T L A

G O

N

IK

O S

C U

T T

J U

L Y

R

T A

S U

B M

IT

T

A L

J U

L Y

R

E V

IS

E

D F

O R

B

ID

D E

R I N

Q U

IR

IE

S S

E P

T

File details come from the government source that posted it. Updated .