DENTAC B785 Amendment 4 drawings.pdf

PDF 644 KB Posted

Attached to
Repair Building 785 Federal contract opportunity
Solicitation number
W912DS22B0019
Issued by
Department of the Army Corps of Engineers Engineering District New York

About this file

This solicitation is for repair and renovation services for Building 785 at the United States Military Academy in West Point, NY. The work includes providing a certified Dental Clinic for the US Army Dental Activity Command. The procurement is set aside for Full and Open Competition with a Firm Fixed Price contract to be awarded by the New York District of the US Army Corps of Engineers. Offerors must submit responses by the date listed in solicitation number W912DS22B0019. The work will include mechanical, electrical, plumbing and telecommunications services to repair and renovate the building to requirements for a Dental Clinic.

View the file

Other files for this federal contract opportunity

Show all 25

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

SEAL

M-601

B785

M E

C H

A N

IC

A

L S

C H

E D

U L E

S

W E

S T

P O

IN

T

N

Y N

E W

Y O

R K

D

IS

T R

IC

T

T N

E W

S W

A N

G E

R

J F

L Y

N N

S S

A B

A N

A Y

A G

A M

J M

A T

T H

E W

S

A U

G U

S T

W R

E

W -1

-D

-0

F

IL

E N

A M

E

R T

A S

U B

M

IS

S

IO

N A

U G

U S

T

D E

N T

A C

M

E P

F R

.R

V T

R E

P A

IR

B

U

IL

D

IN

G

D

E N

T A

C

W S

P U

S A

R

D S

T N

W W

A S

H

IN

G T

O N

D

C

AIR-COOLED CHILLER SCHEDULE

MARK DESCRIPTION

CAPACITY

(TONS)

INPUT

(KW)

PERFORMANCE

(EER)

IPLV

MIN

PARTIAL

LOAD (%)

AMBIENT DB

TEMPERATURE

(°F)

EVAPORATOR COMPRESSOR ELECTRICAL

WEIGHT

(LBS)

NOTESEWT

(°F)

LWT

(°F)

FLOW RATE

(GPM)

WPD (FT.

H2O)

QTY TYPE

MOTOR

SPEED

(RPM)

MOTOR

STARTER

NUMBER

OF

CIRCUITS

VOLTAGE PHASE MCA

CH-1

AIR COOLED

SCROLL COMP

58.5 60.89 11.53 15.65 25 88 57.0 42.0 99.2 5.3 4 SCROLL 1140

ACROSS THE LINE

WITH NEMA 3R BOX

2 460 3 132 3155 1 THRU 15

AIR TERMINAL SCHEDULE

MARK SERVICE TYPE

FACE SIZE

(INCHES)

NECK SIZE

(INCHES)

MAX

FLOW

(CFM)

MAX APD

(IN. WG.)

MAX NC

LEVEL

NOTES

E-1 EXHAUST LAY-IN 24 X 24 12 X 12 400 0.1 30 1

E-2 EXHAUST LAY-IN 12 X 12 8 X 8 250 0.1 30 1

R-1 RETURN LAY-IN 24 X 24 12 X 12 400 0.1 30 1

R-2 RETURN LAY-IN 12 X 12 8 X 8 250 0.1 30 1

S-1 SUPPLY LAY-IN 24 X 24 6 125 0.1 30 1

S-2 SUPPLY LAY-IN 24 X 24 220 0.1 30 1

S-3 SUPPLY LAY-IN 24 X 24 10 325 0.1 30 1

S-4 SUPPLY LAY-IN 12 X 12 6 130 0.1 30 1

S-5 SUPPLY LAY-IN 12 X 12 300 0.1 30 1

S-6 SUPPLY SURFACE MTD 12 X 12 8 300 0.1 30 1

S-7 SUPPLY LINEAR SLOT 4 FT LONG - 400 0.1 30 1, 2

NOTES:

1. COORDINATE COLOR AND FINISH WITH ARCHITECT.

2. LINEAR DIFFUSERS SHALL BE PLENUM SLOT TYPE AND SHALL HAVE TWO SLOTS WITH 1 INCH SLOT WIDTH. PROVIDE

WITH MANUFACTURER'S PLENUM.

DUCTLESS SPLIT SYSTEM SCHEDULE

MARK LOCATION

OUTDOOR

UNIT

COOLING CAPACITY

(MBH)

AIRFLOW

(CFM)

SEER

MOTOR -

OUTDOOR (W)

MCA

(OUTDOOR)

MOCP

(OUTDOOR)

VOLTAGE PHASE NOTES

DSS-1 MAIN COMM - 102 DSCU-1 36 920 18.8 74 25 31 208 1 1, 2, 4

DSS-2 MAIN ELEC - 120 DSCU-2 18 455 19.8 46 11 28 208 1 1, 2, 4

DSS-3 ELEV MACH - 100D DSCU-3 30 775 19.8 86 19 26 208 1 1, 2, 4

DSS-4 ELEC - 221 DSCU-4 30 775 19.8 86 19 26 208 1 1, 2, 4

DSS-5 COMM - 204 DSCU-5 24 775 21.4 86 19 26 208 1 1, 2, 4

DSS-6 DENTAL MECH - 130 DSCU-6 48 1400 14 140 29.1 35 208 1 1,2,3

DSS-7 DENTAL MECH - 130 DSCU-7 48 1400 14 140 29.1 35 208 1 1,2,3

DSS-8 ELEC - 227 DSCU-8 18 455 19.8 46 11 28 208 1 1, 2

ROOF HOOD SCHEDULE

MARK SERVES

AIRFLOW

(CFM)

ECONOMIZER

AIRFLOW

(CFM)

STATIC

PRESSURE

(IN-WG)

THROAT

SIZE

NOTES

RH-1 AHU-1 INTAKE 5200 15000 0.1 66 X 50 1

NOTES:

1. PROVIDE COMPRESSOR SOUND BLANKET.

2. PROVIDE CHILLER WITH AMBIENT CONTROL DOWN TO 0 DEG. F AN UP TO 105 DEG. F.

3. CHILLER SHALL BE MOUNTED ON RUBBER-IN-SHEAR PADS, SIZED AND LOCATED PER MANUFACTURER

RECOMMENDATION.

4. MULTIPLE REFRIGERANT CIRCUITS WITH HOT GAS BYPASS ON LEAD CIRCUIT.

5. SAFETY AND OPERATING CONTROLS INCLUDE SYSTEMS OFF/ON SWITCH, FLOW SENSOR, HIGH PRESSURE

CONTROL(S), LOW EVAPORATOR PRESSURE FREEZE CONTROL(S), AND MICROPROCESSOR CHILLED

WATER CONTROL.

EXHAUST FAN SCHEDULE

MARK SERVES TYPE

AIRFLOW

(CFM)

ESP

(IN-WG)

DRIVE

TYPE

MOTOR

(HP)

MOTOR

(RPM)

VOLTAGE PHASE

WEIGHT

(LBS)

NOTES

EF-1 257 - TLT STAFF CENTRIFUGAL, DOWNBLAST 90 0.12 DIRECT 1/100 1300 115 1 22 2, 4

EF-2 240 - PROSTH. LAB CENTRIFUGAL, DOWNBLAST 985 0.48 DIRECT 1/4 1725 115 1 41 1, 2, 4

EF-3 234, 245 - JAN, RESTROOM CENTRIFUGAL, DOWNBLAST 145 0.12 DIRECT 1/60 1300 115 1 23 2, 4

EF-4 257 - TLT STAFF CENTRIFUGAL, DOWNBLAST 100 0.11 DIRECT 1/100 1300 115 1 22 2, 4

EF-5

100A, 100B, 200A, 200B -

RESTROOMS

CENTRIFUGAL, DOWNBLAST 850 1.76 DIRECT 3/4 1883 115 1 61 2, 4

EF-6 216 - DECON CENTRIFUGAL, DOWNBLAST 1635 0.21 DIRECT 1/2 1725 115 1 49 2 THRU 4

EF-7

110, 112A, 113, 114, 116, 118A -

RESTROOMS, JAN, SOILED

CENTRIFUGAL, DOWNBLAST 1230 0.33 DIRECT 1/2 1725 115 1 49 2, 4

EF-8 226 - TLT PAT CENTRIFUGAL, DOWNBLAST 75 0.11 DIRECT 1/200 1050 115 1 22 2, 4

EF-9 205 - TLT STAFF CENTRIFUGAL, DOWNBLAST 75 0.11 DIRECT 1/200 1050 115 1 22 2, 4

EF-10 240 - PROSTH. LAB CENTRIFUGAL, STACK 310 0.65 BELT 1-1/2 3600 460 3 464 2 THRU 5

EF-11 212 - INST. STOR. CENTRIFUGAL, DOWNBLAST 250 0.16 DIRECT 1/30 1550 115 1 23 2 THRU 4

EF-12 214 - STERIL CENTRIFUGAL, DOWNBLAST 500 0.24 DIRECT 1/12 1300 115 1 34 2 THRU 4

EF-13 246 - PREP CENTRIFUGAL, DOWNBLAST 560 0.17 DIRECT 1/15 1550 115 1 29 2 THRU 4

NOTES:

1. MINIMUM HEIGHT FROM ROOF: 3'-0".

6. NEMA 4 PANEL CONTROL CENTER WITH SAFETY AND OPERATING CONTROLS, UL 508 LABELED.

7. CONTROLLER WITH LCD DISPLAY, PROVIDE LONWORKS INTERFACE TO CONNECT TO BUILDING CONTROL NETWORK.

8. CONTROL CIRCUIT TRANSFORMER WITH CONVENIENCE OUTLET.

9. 30% PROPYLENE GLYCOL SOLUTION.

AIR HANDLING UNIT SCHEDULE (CONTINUED)

SUPPLY FAN RETURN FAN

WEIGHT

(LBS)

NOTESMOTOR

(HP)

MOTOR

(RPM)

ESP

(IN-WG)

DRIVE

TYPE

VOLTAGE PHASE

AIRFLOW

(CFM)

MOTOR

(HP)

MOTOR

(RPM)

ESP

(IN-WG)

DRIVE

TYPE

VOLTAGE PHASE

25 1750 4.0 VFD 460 3 10800 15 1750 2.0 VFD 460 3 8410 1 THRU 3

NOTES:

1. PROVIDE FAN WITH ELECTRONICALLY COMMUTATED MOTOR FOR VARIABLE SPEED OPERATION.

2. FURNISH AND INSTALL WITH OPTIONAL MANUFACTURER ROOF CURB.

3. DUCTWORK IN ASSOCIATED SYSTEM TO BE STAINLESS STEEL 316.

4. PROVIDE WITH RPM METER.

5. EXHAUST STACK 10' ABOVE ROOF WITH MINIMUM 3,000 FPM EXIT VELOCITY.

AIR HANDLING UNIT SCHEDULE

MARK LOCATION

MAXIMUM

SUPPLY

AIR FLOW

(CFM)

HEATING

SUPPLY

AIRFLOW

(CFM)

OUTSIDE

AIR FLOW

(CFM)

CHILLED WATER COIL HEATING WATER COIL

FILTER

MERV

RATING

PRE/FINAL

TOTAL

(MBH)

SENSIBLE

(MBH)

LATENT

COOLING

CAPACITY

(MBH)

SENSIBLE

HEAT

RATIO

MAX COIL

FACE

VELOCITY

(FPM)

COIL ΔP

(AIR - IN-WG)

EAT

DB/WB (°F)

LAT

DB/WB(°F)

WATER

FLOW

(GPM)

COIL ΔP

(WATER -

FT H2O)

COIL FOULING

FACTOR

(FT²·°F·HR/BTU)

EWT

(°F)

LWT

(°F)

HEATING

CAPACITY

(MBH)

MAX COIL

FACE

VELOCITY

(FPM)

COIL ΔP

(AIR - IN-WG)

EAT

(°F)

LAT

(°F)

WATER

FLOW

(GPM)

COIL ΔP

(WATER -

FT H2O)

EWT

(°F)

LWT

(°F)

AHU-1 124 - MECH 16000 11300 5200 735 453 282 62% 550 0.89 78.5/66.9 52.0/51.6 101 16.8 0.0005 42 57 295 550 0.09 34.2 55 20.4 4.7 140 110 8/14

NOTES:

1. UNIT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATION.

2. PROVIDE ONE VFD PER FAN.

3. UNIT IS DERATED FOR 30% PROPYLENE GLYCOL CHILLED WATER MIXTURE.

4. INSTALL UNIT WITH 24-INCH MINIMUM CLEARANCE ON ALL SIDES. PROVIDE ADDITIONAL MAINTENANCE CLEARANCE AS RECOMMENDED BY MANUFACTURER AND TO ALLOW FOR COIL REMOVAL.

NOTES:

1. PROVIDE WITH CONDENSATE INLINE PUMP.

2. LOW AMBIENT COOLING OPERATION.

3. PROVIDE MESH SCREEN ON DISCHARGE.

4. PROVIDE MANUFACTURER'S WALL MOUNTING KIT FOR OUTDOOR UNIT AND MOUNT BOTTOM OF UNIT

36" ABOVE GRADE.

HUMIDIFIER SCHEDULE

MARK LOCATION

CAPACITY

LBS/HR

QTY OF

STEAM

OUTLET

STEAM

OUTLET

(INCHES)

MAKEUP

WATER

(INCHES)

FILL RATE

(GPM)

DRAIN

RATE

(GPM)

MIN/MAX

WATER

PRESSURE

(PSIG)

INPUT

(KW)

VOLTAGE/PH

RATED

CURRENT

(MCA)

MAX

CURRENT

(MOCP)

WEIGHT

(LBS)

NOTES

HM-1 124 - MECH 66.4 1 1.75 0.5 0.5 6.70 30/80 24.3 208/3 67.5 90.0 89 1 THRU 8

NOTES:

1. UNIT SHALL BE WALL MOUNTED.

2. PROVIDE MANUFACTURER'S MODULATING CONTROLLER, AIR FLOW PROVING AND MODULATING HIGH LIMIT.

3. PROVIDE WITH REMOTE BLOWER PACK UNIT.

4. PROVIDE DUCT MOUNTED STEAM DISPERSION PANEL WITH A MAXIMUM ABSORPTION DISTANCE OF 3 FEET.

LOUVER SCHEDULE

MARK SERVICE

AIRFLOW

(CFM)

SIZE

(IN. X IN.)

FREE AREA

(SQFT)

MAX TOTAL PRESSURE

(IN. WG.)

L-1 RELIEF 11600 52 X 84 17 0.1

5. PROVIDE TOUCHSCREEN CONTROL WITH INTUITIVE COLOR USER INTERFACE.

6. PROVIDE OVER TEMPERATURE SAFETY SWITCH.

7. PROVIDE INTEGRAL CONDESATE LEG TO DRAIN.

A

M E

N D

M E

N T

S E

P '2

C T

-1

CT

-17

ORAL EVACUATION PUMP SCHEDULE

MARK REMARKS

OE-1 DRY TYPE DUPLEX VACUUM PUMPS, VARIABLE SPEED PUMPS,

AUTOMATIC SEPARATION TANK WASHOUT, AMALGAM SEPARATOR,

1-1/2" INLET/OUTLET.

TYPE LOCATION

PUMP

HP

(EACH)

DUPLEX

DENTAL EQUIPMENT

MECHANICAL ROOM 300

SCFM

(PUMP)

VOLTS/PHASE

/Hz

SEPARATION

TANK

(GALLONS)

5.0 208/3/60 80

SCFM

(SYSTEM)

NOTES:

1. INSTALL ORAL EVACUATION SYSTEM PER MANUFACTURER'S RECOMMENDATIONS.

2. ROUTE SEPARATION TANK WASTE TO NEAREST FLOOR DRAIN, WITH AN AIR GAP.

DENTAL AIR COMPRESSOR SCHEDULE

MARK FLA REMARKS

DAC-1

NOTES:

1. INSTALL AIR COMPRESSOR PER MANUFACTURER'S RECOMMENDATIONS.

2. ROUTE CONDENSATE DRAIN TO NEAREST FLOOR DRAIN, WITH AN AIR GAP.

OIL-FREE, INTEGRATED RECEIVER AND DRYER, AIR FILTER,

SINGLE POINT CONNECTION, WITH ENCLOSURE

TYPE LOCATION

OUTLET

PRESSURE

(PSIG)

RPM

TRIPLEX

DENTAL EQUIPMENT

MECHANICAL ROOM 110

AIR

FLOW

(SCFM)

70.9

HP

EACH

PUMP

VOLTS/

PHASE/Hz

RECEIVER

CAPACITY

(GALLONS)

10 3,600 460/3/60

37.2 200

PLUMBING FIXTURE SCHEDULE

MARK REMARKS

EWC-1 PROVIDE WITH CAST BRASS P-TRAP, 1/4 TURN SUPPLY STOPS, AND CONCEALED CARRIER.

DESCRIPTION

VENT HW

ELECTRIC WATER COOLER

SAN CW

CONNECTION (IN. DIA.)

SK-D DENTAL CONSOLE LAVATORY 1-1/21-1/2 1/2 1/2

L-1

LAVATORY, VITREOUS CHINA,

STRAIGHT BACK

S-1

S-2

WC-1

TOILET, WALL HUNG, SENSOR

ACTIVATED, SIPHON JET

24 1 -

WC-ADA

U-1 URINAL, WALL HUNG 1-1/22 3/4 -

MS-1 MOP SINK, TERRAZO 1-1/23 1/2 1/2

S-3

SS SINK, SINGLE COMPARTMENT,

22 x 20 x 8

1-1/21-1/2 1/2

1-1/21-1/2 1/2 1/2

24 1 -

TOILET, WALL HUNG, ACCESSIBLE

HEIGHT, SENSOR ACTIVATED, SIPHON JET

1-1/21-1/2 1/2 1/2

1-1/21-1/2 1/2 1/2

1-1/21-1/2 1/2 1/2

SS SINK, SINGLE COMPARTMENT,

17 x 20 x 8

SS SINK, SINGLE COMPARTMENT,

15 x 18 x 6

PROVIDE WITH CONCEALED CARRIER AND SEAT WITH OPEN FRONT.

PROVIDE WITH CONCEALED CARRIER AND SEAT WITH OPEN FRONT.

PROVIDE WITH CONCEALED CARRIER.

SINK AND FAUCET ARE INTEGRAL TO LOGCAT-A EQUIPMENT. PROVIDE WITH GRID STRAINER, CAST

BRASS P-TRAP, AND 1/4 TURN SUPPLY STOPS. PROVIDE FOOT PEDAL ACTUATOR.

PROVIDE WITH GRID STRAINER, CAST BRASS P-TRAP, 1/4 TURN SUPPLY STOPS, AND CONCEALED

CARRIER.

PROVIDE WITH GRID STRAINER, CAST BRASS P-TRAP, AND 1/4 TURN SUPPLY STOPS.

PROVIDE WITH GRID STRAINER, CAST BRASS P-TRAP, AND 1/4 TURN SUPPLY STOPS.

PROVIDE WITH GRID STRAINER, CAST BRASS P-TRAP, AND 1/4 TURN SUPPLY STOPS.

PROVIDE WITH DRAIN BODY AND STAINLESS STEEL STRAINER.

FD-1 FLOOR DRAIN 1-1/23 - -

NICKLE BRONZE STRAINER WITH CAST IRON BODY. PROVIDE DRAIN MANUFACTURER'S TRAP PRIMER

CONNECTION IN DRAIN BODY OR IN TRAP STANDPIPE AT DRAIN OUTLET.

FS-1 FLOOR SINK 1-1/23 - -

NICKLE BRONZE HALF GRATE WITH CAST IRON BODY. PROVIDE DRAIN MANUFACTURER'S TRAP PRIMER

CONNECTION IN DRAIN BODY OR IN TRAP STANDPIPE AT DRAIN OUTLET.

JSN

NO.

R2201

D0680

P3000

CS010

CS040

CS090

P9050

P9050

P8150

P4700

CS180

CS200

S-4

S-5

SS SINK, SINGLE COMPARTMENT,

12 x 22 x 16

1-1/21-1/2 1/2 1/2 PROVIDE WITH GRID STRAINER, CAST BRASS P-TRAP, AND 1/4 TURN SUPPLY STOPS.

SS SINK, SINGLE COMPARTMENT,

12 x 28 x 16

1-1/21-1/2 1/2 1/2 PROVIDE WITH GRID STRAINER, CAST BRASS P-TRAP, AND 1/4 TURN SUPPLY STOPS.

L-2

LAVATORY, VITREOUS CHINA,

SLAB TYPE

P3100 1/2 1/2

PROVIDE WITH GRID STRAINER, CAST BRASS P-TRAP, 1/4 TURN SUPPLY STOPS, AND CONCEALED

CARRIER.

1-1/21-1/2

P5040SH-1 SHOWER, SINGLE, HAND-HELD 1-1/2 1/2 1/22 PROVIDE WITH DRAIN BODY AND STAINLESS STEEL STRAINER.

EW-1 EYE WASH STATION, WALL MOUNTED 1 1/41 1/4P2000 1/2 1/2

PROVIDE WITH ASSE 1071 EMERGENCY MIXING VALVE SET TO 85°F, FLOW SWITCH ACTIVATED

AUDIBLE ALARM AND STROBE, WITH ALARM SHUT-OFF TO BE INSTALLED NEARBY FIXTURE.

PLUMBING EQUIPMENT SCHEDULE

MARK REMARKS

SP-1

DESCRIPTION

DRAINTILE SUMP PUMP

SP-2 ELEVATOR SUMP PUMP,

OIL SENSING

RO-1 REVERSE OSMOSIS GENERATOR

SUMP PUMP WITH OIL SMART SYSTEM., 110 GPM @35FT OF HEAD, 460V / 3PH / 60 HZ, 3.6 AMP, 2HP, OIL SENSING SYSTEM WITH EBARA OM FLOATS, CONTROL PANEL WITH LIGHTS, ALARM SILENCE SWITCH AND REMOTE MONITORING. PROVIDE GATE VALVE AND CHECK VALVE IN PUMP DISCHARGE PIPE, ROUTE DISCHARGE PIPING FULL SIZE TO TERINATION AT FLOOR SINK THROUGH AIR GAP. PROVIDE MONITORING CONNECTION TO BUILDING AUTOMATION SYSTEM.

INSTALL PER MANUFACTURER'S WRITTEN DOCUMENTATION.

60 GPM @20FT OF HEAD, 230V / 1PH / 60 HZ, 8.9 AMP, 1HP, SYSTEM WITH EBARA OM FLOATS, CONTROL PANEL WITH LIGHTS, ALARM SILENCE SWITCH AND REMOTE MONITORING. PROVIDE GATE VALVE AND CHECK VALVE IN PUMP DISCHARGE PIPE. THE PUMP DISCHARGE SHALL CONNECT TO THE OVERHEAD

SEWER PIPE.

FLOOR MOUNTED RO WATER GENERATOR, 1,800 GPD, 450 GAL STORAGE TANK (ST-1), UP TO 37.2 GPM DELIVERY, PRE-CARBON BLOCK FILTER, MAKEUP RATE OF 3 GPM, DISTRIBUTION PUMP RATED FOR 37.2 GPM @ 20 PSI, 2 X 115v, 20AMP.

FCO FLOOR CLEANOUT

WCO WALL CLEANOUT

FINISHED FLOOR CLEANOUT. SQAURE TOP, WITH NICKLE BRONZE FINISH.

ROUGH FINISH STAINLESS STEEL PLUG.

PT-1 PLASTER TRAP CAST ALUMINUM BODY, 6" X 6" X 12", SOLID TOP, HINGED BOTTOM, 1/4" DRAIN PLUG. INSTALL WITH ACCESS CLEARANCE FOR CLEANING AND REMOVAL OF DEBRIS.

DOMESTIC BOOSTER PUMP SCHEDULE

MARK

RPM

REMARKS

DBP-1

NOTES:

1. CONNECT EQUIPMENT TO BUILDING MANAGEMENT SYSTEM.

DUPLEX BOOSTER PUMP SYSTEM, PRE-PIPED, WIRED, AND FACTORY

TESTED, 57 PSI DISCHARGE. PUMP SET FOR 50/50/50 SPLIT, 48/48/48

GPM. PRESSURE GAUGES ON EACH HEADER, VARIABLE FREQUENCY

DRIVE, NEMA 1 CONTROLLER WITH NO-FLOW SHUT DOWN, 120V

CONTROL CIRCUIT, NON-FUSED DISCONNECT, ETHERNET PORT,

DIAPHRAGM TANK. PROVIDE 4" CONCRETE HOUSEKEEPING PAD, AND

FLEXIBLE CONNECTORS BETWEEN PIPING AND SKID. ROUTE DRAIN

PIPING FROM EACH PURGE VALVE TO FLOOR RECEPTOR.

TYPE LOCATION

PUMP

HEAD

(FT) PHASE

DOMESTIC

BOOSTER

PUMP

MECHANICAL

ROOM

41.2

FLOW

(GPM)

VOLTAGE HP

480 3 3 3250

ELECTRICAL

HOT WATER RECIRC PUMP SCHEDULE

MARK

RPM

REMARKS

HWRP-1 STAINLESS STEEL BODY, VARIABLE SPEED DRIVE. CONNECT

CIRCULATION PUMP TO BMS.

TYPE LOCATION

PUMP

HEAD

(FT) PHASE

INLINE MECHANICAL

ROOM

FLOW

(GPM)

VOLTAGE HP

120 1 1/5 -

ELECTRICAL

DOMESTIC WATER HEATER SCHEDULE

MARK REMARKS

DWH-1

TYPE LOCATION

RECOVERY

(GAL/HR)

MIN

PRESSURE

NG-FIRED,

STORAGE

MECHANICAL

ROOM

STORAGE

(GAL)

MBH

MAX

PRESSURE

76 5.2-IN W.C. 8-IN W.C.

NATURAL GAS INPUTMIN

UEF

0.69

STORAGE

TEMP

SETPOINT

(°F)

DWH-2

NG-FIRED,

STORAGE

MECHANICAL

ROOM

7475 76 8-IN W.C.0.69 140

TEMP

RISE

(°F)

V/Ph/A

NOTES:

1. PROVIDE WITH FACTORY MOUNTED BLOWER.

2. PROVIDE WITH CONDENSATION NEUTRALIZATION KIT.

1, 2

1, 2

120 / 1 / 4

5.2-IN W.C. 120 / 1 / 4

DWH-3

NG-FIRED,

STORAGE

MECHANICAL

ROOM

7475 76 8-IN W.C.0.69 140 100 1, 25.2-IN W.C. 120 / 1 / 4

ZONE VALVE BOX SCHEDULE

SERVINGLOCATION

AREA

ALARMN N2ODSVDAO

SIZE OF PIPING & VALVE (DIAMETER IN INCHES)

MARK

WAGD CO2

3/4" --

ROOMS

248, 250, 252

ZVB-1 AA-1- - 3/4" -

CIRCULATION

2C4

MED GAS EQUIPMENT SCHEDULE

ITEM DESCRIPTIONMARK

AA-1

MASTER ALARM PANEL

AREA ALARM PANEL

MA-1

MFGR / MODEL NO.

COLOR TOUCH SCREEN HMI, 120V

COLOR TOUCH SCREEN HMI, 120V

DENTAL SURGICAL VACUUM PUMP SCHEDULE

TAG REMARKS

DSV-1

STACK-MOUNTED DUPLEX VACUUM PUMP, INTEGRAL PRE-WIRED

CONTROL PANEL WITH EXTERNAL DISCONNECT, HORIZONTAL

RECIEVER WITH 3-VALVE BYPASS.

TYPE LOCATION

PUMP

HP

(EACH)

DUPLEX

CLAW

TYPE

DENTAL EQUIPMENT

MECHANICAL ROOM 8

SCFM

(PUMP)

VOLTS/PHASE/FLA

RECIEVER

TANK

(GALLONS)

2.0 208/3/7.8 60

SCFM

(SYSTEM)

NOTES:

1. INSTALL DENTAL SURGICAL VACUUM SYSTEM PER MANUFACTURER'S RECOMMENDATIONS.

2. ROUTE CONDENSATE DRAIN TO NEAREST FLOOR DRAIN, WITH AN AIR GAP.

WATER SOFTENER SCHEDULE

MARK

WS-1

LOCATION

MECHANICAL

ROOM

WORKING

PRESSURE

(PSI)

TOTAL CAPACITY:

KILOGRAIN/LB SALT

60 / 18

FLOW RATES, EACH

90 / 45

NOTES:

1. ENGAGE THE LOCAL EQUIPMENT REPRESENTATIVE THAT SERVICES KACH EQUIPMENT TO DETERMINE ALL

PARAMETERS ARE CURRENT SO THE FACILITY WATER HARDNESS DOES NOT EXCEED 5 GRAINS PER GALLON.

2. 3 CUBIC FEET OF RESIN.

CONTINUOUS

GPM Δ PSI

35 15

PEAK

GPM Δ PSI

95 15

MINIMUM

CAPACITY

MAXIMUM

CAPACITY

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

SEAL

P-601

B785

P L U

M B

IN

G

S C

H E

D U

L E

S

W E

S T

P O

IN

T

N

Y N

E W

Y O

R K

D

IS

T R

IC

T

T N

E W

S W

A N

G E

R

J F

L Y

N N

S S

A B

A N

A Y

A G

A M

J M

A T

T H

E W

S

A U

G U

S T

W R

E

W -1

-D

-0

F

IL

E N

A M

E

R T

A S

U B

M

IS

S

IO

N A

U G

U S

T

D E

N T

A C

M

E P

F R

.R

V T

R E

P A

IR

B

U

IL

D

IN

G

D

E N

T A

C

W S

P U

S A

R

D S

T N

W W

A S

H

IN

G T

O N

D

C

A

M E

N D

M E

N T

S E

P '2

CT

-17

C T

-1

2E1E 1N 2N 3N 5N

HN

GE

FE

EE

FN

MECH

124HWRP-1 DAC-1

OE-1

2" OE

ST-1

DSV-1

DENTAL MECH

AHU-1

1 1/2" WAGD

2" OEE

DBP-1

RO-1

1 1/4" DAI UP

DWH-1

DWH-2

DWH-3

4N 6N

GN

3/4" WAGD

1-1/2" DSV

1 1/4" DA

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

SEALGRAPHIC SCALES

PLAN NORTH

2' 4' 8'

1/4"=1'-0SCALE:

KEY PLAN

A

B

C

D

PG104

B785

P L U

M B

IN

G

F

IR

S T

F L O

O R

D E

N T

A L G

A S

P L A

N A

R E

A D

W E

S T

P O

IN

T

N

Y N

E W

Y O

R K

D

IS

T R

IC

T

T N

E W

S W

A N

G E

R

J F

L Y

N N

S S

A B

A N

A Y

A G

A M

J M

A T

T H

E W

S

A U

G U

S T

W R

E

W -1

-D

-0

F

IL

E N

A M

E

R T

A S

U B

M

IS

S

IO

N A

U G

U S

T

D E

N T

A C

M

E P

F R

.R

V T

R E

P A

IR

B

U

IL

D

IN

G

D

E N

T A

C

W S

P U

S A

R

D S

T N

W W

A S

H

IN

G T

O N

D

C

1/4" = 1'-0" D1

PLUMBING FIRST FLOOR DENTAL GAS PLAN AREA D

A

M E

N D

M E

N T

S E

P '2

C T

-1

CT

-17

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

SEAL

E-603

B785

E L E

C T

R

IC

A L P

A N

E L S

C H

E D

U L E

S

W E

S T

P O

IN

T

N

Y N

E W

Y O

R K

D

IS

T R

IC

T

B C

O N

N E

R

I.

T

A

IF

O R

S S

A B

A N

A Y

A G

A M

J A

H O

U N

O U

A U

G U

S T

W R

E

W -1

-D

-0

F

IL

E N

A M

E

R T

A S

U B

M

IS

S

IO

N A

U G

U S

T

D E

N T

A C

M

E P

F R

.R

V T

R E

P A

IR

B

U

IL

D

IN

G

D

E N

T A

C

W S

P U

S A

R

D S

T N

W W

A S

H

IN

G T

O N

D

C

HVAC 11440 VA 100.00% 11440 VA TOTAL ESTIMATED DEMAND CURRENT: 344 A

RECEPTACLES 8120 VA 100.00% 8120 VA TOTAL CONNECTED CURRENT: 311 A

MOTORS 230381 VA 111.91% 257817 VA

MISCELLANEOUS 8987 VA 100.00% 8987 VA TOTAL ESTIMATED DEMAND LOAD: 286389 VA

HEAT 13 VA 100.00% 13 VA TOTAL CONNECTED LOAD: 258954 VA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS

CIRCUIT NOTES:

PANEL NOTES:

TOTAL CONNECTED CURRENT: 319 A 305 A 312 A

TOTAL CONNECTED LOAD: 88114 VA 84606 VA 86233 VA

53 SPACE -- -- -- 0 VA 0 VA -- -- -- SPACE 54

51 SPACE -- -- -- 0 VA 0 VA -- -- -- SPACE 52

49 SPARE -- -- -- 0 VA 0 VA -- -- -- SPARE 50

47 SPARE -- -- -- 0 VA 0 VA -- -- -- SPARE 48

45 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 46

43 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 44

41 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 42

39 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 40

37 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 38

35 -- -- -- -- 1330 VA 783 VA -- -- -- -- 36

33 -- -- -- -- 1330 VA 1653 VA -- -- -- -- 34

31 DBP-1 MECH 130 15 A 3 1330 VA 1723 VA 3 60 A T-TRL2 32

29 -- -- -- -- 783 VA 5820 VA -- -- -- -- 30

27 -- -- -- -- 1473 VA 5820 VA -- -- -- -- 28

25 T-TRL1 60 A 3 1903 VA 5820 VA 3 40 A AHU-1 RETURN FAN 26

23 -- -- -- -- 10309 VA 9422 VA -- -- -- -- 24

21 -- -- -- -- 10309 VA 9422 VA -- -- -- -- 22

19 DAC-1 MECH 124 20 A 3 10309 VA 9422 VA 3 70 A AHU-1 SUPPLY FAN 20

17 -- -- -- -- 497 VA 497 VA -- -- -- -- 18

15 -- -- -- -- 497 VA 497 VA -- -- -- -- 16

13 CHWP-01 MECH 124 15 A 3 497 VA 497 VA 3 15 A CHWP-02 MECH 124 14

11 -- -- -- -- 373 VA 373 VA -- -- -- -- 12

9 -- -- -- -- 373 VA 373 VA -- -- -- -- 10

7 HWP-01 MECH 124 15 A 3 373 VA 373 VA 3 15 A HWP-02 MECH 124 8

5 -- -- -- -- 36581 VA 19464 VA -- -- -- -- 6

3 -- -- -- -- 36581 VA 16277 VA -- -- -- -- 4

1 CH-1 BASEMENT 150 A 3 36581 VA 19284 VA 3 90 A T-1ML 2

CKT

# CIRCUIT DESCRIPTION

CKT

NOTES TRIP POLES A B C POLES TRIP

CKT

NOTES CIRCUIT DESCRIPTION

CKT

ENCLOSURE: NEMA 1 BUS TYPE: Copper MCB: N/A

MOUNTING: Surface WIRES: 4 MAIN BUS: 600 A

FED FROM: MDP PHASES: 3 PANEL LUGS: MLO

LOCATION: MAIN ELEC 120 VOLTAGE: 480/277V AIC: 42kAIC

BRANCH PANEL: 1MH BRANCH: EQUIPMENT

TOTAL ESTIMATED DEMAND CURRENT: 162 A

HVAC 11440 VA 100.00% 11440 VA TOTAL CONNECTED CURRENT: 153 A

MOTORS 34772 VA 110.09% 38282 VA

MISCELLANEOUS 8787 VA 100.00% 8787 VA TOTAL ESTIMATED DEMAND LOAD: 58535 VA

HEAT 13 VA 100.00% 13 VA TOTAL CONNECTED LOAD: 55025 VA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS

CIRCUIT NOTES:

PANEL NOTES:

TOTAL CONNECTED CURRENT: 165 A 136 A 166 A

TOTAL CONNECTED LOAD: 19284 VA 16277 VA 19464 VA

53 SPARE 20 A 1 0 VA 0 VA -- -- -- SPACE 54

51 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 52

49 VAV CONTROLS 20 A 1 100 VA 0 VA 1 20 A SPARE 50

47 VAV CONTROLS 20 A 1 100 VA 0 VA 1 20 A SPARE 48

45 VAV CONTROLS 20 A 1 100 VA 0 VA 1 20 A SPARE 46

43 VAV CONTROLS 20 A 1 100 VA 0 VA 1 20 A SPARE 44

41 VAV CONTROLS 20 A 1 100 VA 0 VA 1 20 A SPARE 42

39 VAV CONTROLS 20 A 1 100 VA 0 VA 1 20 A SPARE 40

37 VAV CONTROLS 20 A 1 100 VA 0 VA 1 20 A SPARE 38

35 VAV CONTROLS 20 A 1 100 VA 13130 VA -- -- -- -- 36

33 J BOX ROOF EF-11 20 A 1 127 VA 11231 VA -- -- -- -- 34

31 J BOX ROOF EF-12 20 A 1 127 VA 13953 VA 3 150 A PANEL 1MLB 32

29 J BOX ROOF EF-13 20 A 1 127 VA 1144 VA -- -- -- -- 30

27 -- -- -- -- 1144 VA 1144 VA 2 30 A DSCU-4 28

25 DSCU-5 30 A 2 1144 VA 1144 VA -- -- -- -- 26

23 -- -- -- -- 1144 VA 1144 VA 2 30 A DSCU-2 24

21 DSCU-3 30 A 2 1144 VA 13 VA 1 20 A J BOX UH - 13 RM 121A 22

19 -- -- -- -- 1144 VA 124 VA 1 20 A J BOX ROOF EF - 7 20

17 DSCU-1 30 A 2 1144 VA 373 VA 1 20 A J BOX ROOF EF - 6 18

15 J BOX UH-5 BASEMENT 20 A 1 13 VA 50 VA 1 20 A J BOX ROOF EF - 9 16

13 J BOX UH-4 BASEMENT 20 A 1 13 VA 186 VA 1 20 A J BOX ROOF EF - 5 14

11 -- -- -- -- 450 VA 50 VA 1 20 A J BOX ROOF EF - 8 12

9 J BOX DSS-5 RM 204 20 A 2 450 VA 124 VA 1 20 A J BOX ROOF EF - 4 10

7 -- -- -- -- 450 VA 124 VA 1 20 A J BOX ROOF EF- 3 8

5 J BOX DSS-1 RM 102 20 A 2 450 VA 8 VA 1 20 A J BOX ROOF EF- 1 6

3 -- -- -- -- 450 VA 186 VA 1 20 A J BOX ROOF EF- 2 4

1 J BOX DSS-3 RM 100-D 20 A 2 450 VA 124 VA 1 20 A J BOX ROOF EF- 10 2

CKT

# CIRCUIT DESCRIPTION

CKT

NOTES TRIP POLES A B C POLES TRIP

CKT

NOTES CIRCUIT DESCRIPTION

CKT

ENCLOSURE: Type 1 BUS TYPE: Copper MCB: -

MOUNTING: Surface WIRES: 4 MAIN BUS: 250 A

FED FROM: T-1ML PHASES: 3 PANEL LUGS: MLO

LOCATION: MAIN ELEC 120 VOLTAGE: 208/120V AIC: 10kAIC

BRANCH PANEL: 1ML BRANCH: EQUIPMENT

TOTAL ESTIMATED DEMAND CURRENT: 116 A

TOTAL CONNECTED CURRENT: 106 A

MOTORS 32072 VA 110.94% 35582 VA TOTAL ESTIMATED DEMAND LOAD: 41824 VA

MISCELLANEOUS 6242 VA 100.00% 6242 VA TOTAL CONNECTED LOAD: 38314 VA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS

CIRCUIT NOTES:

PANEL NOTES:

TOTAL CONNECTED CURRENT: 119 A 94 A 112 A

TOTAL CONNECTED LOAD: 13953 VA 11231 VA 13130 VA

41 SPACE -- -- -- 0 VA 0 VA 1 20 A SPARE 42

39 SPACE -- -- -- 0 VA 0 VA 1 20 A SPARE 40

37 SPACE -- -- -- 0 VA 0 VA 1 20 A SPARE 38

35 SPACE -- -- -- 0 VA 0 VA 1 20 A SPARE 36

33 SPACE -- -- -- 0 VA 0 VA 1 20 A SPARE 34

31 SPACE -- -- -- 0 VA 0 VA 1 20 A SPARE 32

29 SPACE -- -- -- 0 VA 0 VA 1 20 A SPARE 30

27 SPACE -- -- -- 0 VA 0 VA 1 20 A SPARE 28

25 -- -- -- -- 1144 VA 0 VA 1 20 A SPARE 26

23 DSCU-8 15 A 2 1144 VA 0 VA 1 20 A SPARE 24

21 -- -- -- -- 3016 VA 0 VA 1 20 A SPARE 22

19 DSCU-7 40 A 2 3016 VA 0 VA 1 20 A SPARE 20

17 -- -- -- -- 3016 VA 0 VA 1 20 A SPARE 18

15 DSCU-6 40 A 2 3016 VA 4680 VA -- -- -- -- 16

13 J BOX RO-1 MECH 124 20 A 1 2300 VA 4680 VA -- -- -- -- 14

11 J BOX RO-1 MECH 124 20 A 1 2300 VA 4680 VA 3 90 A HM-1 MECH 124 12

9 J BOX UH-03 VEST 100C 20 A 1 13 VA 13 VA 1 20 A J BOX UH-10 DENTAL MECH... 10

7 B-2 MECH 124 15 A 1 1840 VA 13 VA 1 20 A J BOX UH-1 MECH 124 8

5 J BOX HWRP-1 MECH 124 20 A 1 150 VA 1840 VA 1 15 A B-1 MECH 124 6

3 J BOX DWH-1 MECH 124 20 A 1 480 VA 13 VA 1 20 A J BOX UH-3 MECH 124 4

1 J BOX DWH-2 MECH 124 20 A 1 480 VA 480 VA 1 20 A J BOX DWH-3 MECH 124 2

CKT

# CIRCUIT DESCRIPTION

CKT

NOTES TRIP POLES

CONNECTED LOAD

PHASE A

CONNECTED LOAD

PHASE B

CONNECTED LOAD

PHASE C POLES TRIP

CKT

NOTES CIRCUIT DESCRIPTION

CKT

ENCLOSURE: Type 1 BUS TYPE: Copper MCB: 200 A

MOUNTING: Surface WIRES: 4 MAIN BUS: 225 A

FED FROM: 1ML PHASES: 3 PANEL LUGS: MCB

LOCATION: MECHANICAL 124 VOLTAGE: 208/120V AIC: 10kAIC

1MLB BRANCH:

A

M E

N D

M E

N T

S E

P '2

C T

-1

J

J

J

J J

J J

J J

J

J

J

J

1E 1N 2N 3N 5N

HN

GE

FE

EE

FN

MECH

HWRP-1 DAC-1

GFCI

GFCI

CHWP-1

CHWP-2

100/-/3

HWP-1

HWP-2

UH-1

UH-2

GFCI

GFCI

GFCI

GFCI

GFCI

GFCI

1LA - 30

1MLB - 8

1MLB - 4

RO-1

DSV-1

30/-/3

30/-/3

30/-/3

30/-/3

30/-/130/-/1

1MLB - 5

30/-/3

1MLB - 1

1MLB - 2

1MLB - 6

1MLB - 11

1MLB - 13

AHU-1

OE-2

OE-1

OE-1

1MH - 19,21,23

30/-/3

1MH - 8,10,12

1MH - 13,15,17

1MH - 14,16,18

2EQL - 9,11,13

3#4,#8G,1"C

1MH - 20,22,24

AHU-1

SUPPLY FAN

1MH - 26,28,30

3#8,#10G,3/4"C

60/-/3

AHU-1

RETURN FAN

2EQL - 15,17,19

2EQL - 21,23,25

2EQL - 10,12,14

3#8,#10G,3/4"C

3#8,#10G,3/4"C

3#8,#10G,3/4"C

NEMA 3R

1MH - 7,9,11

4N

GN

DENTAL MECH

1MLB - 3

DWH-1

DWH-2

DWH-3

NEMA 3R

NEMA 3R

NEMA 3R

NEMA 3R

NEMA 3R

NEMA 3R

NEMA 3R

1MLB - 7

BT-1

ET-1

GF-2

1LA - 7

GF-1

HM-1

GFIWP

100/-/3

B-1

B-2

DSS-6DSS-7

ST-1

1MLB

UH-10

1MLB - 10

DBP-1

1MH - 31,33,35

3#2,#8G,1-1/4"C

1MLB - 12,14,16

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

SEALGRAPHIC SCALES

PLAN NORTH

SHEET NOTES

2' 4' 8'

1/4"=1'-0SCALE:

KEY PLAN

A

B

C

D

EP104

B785

E L E

C T

R

IC

A L F

IR

S

T F

L O

O R

P O

W E

R P

L A

N A

R E

A D

W E

S T

P O

IN

T

N

Y N

E W

Y O

R K

D

IS

T R

IC

T

B C

O N

N E

R

I.

T

A

IF

O R

S S

A B

A N

A Y

A G

A M

J A

H O

U N

O U

A U

G U

S T

W R

E

W -1

-D

-0

F

IL

E N

A M

E

R T

A S

U B

M

IS

S

IO

N A

U G

U S

T

D E

N T

A C

M

E P

F R

.R

V T

R E

P A

IR

B

U

IL

D

IN

G

D

E N

T A

C

W S

P U

S A

R

D S

T N

W W

A S

H

IN

G T

O N

D

C

1/4" = 1'-0" F1

ELECTRICAL FIRST FLOOR POWER PLAN AREA D

1. CONTRACTOR IS TO PROVIDE LABELS FOPR ALL RECEPTACLES DENOTING

PANEL AND CIRCUIT NUMBER.

KEYNOTES

MARK DESCRIPTION

EQUIPMENT TO BE PROVIDED WITH VFD. COORDINATE EXACT INSTALLATION

REQUIREMENTS WITH MECHANICAL DRAWINGS AND SPECIFICATIONS.

A

M E

N D

M E

N T

A U

G '2

A

M E

N D

M E

N T

S E

P '2

FIRE ALARM GENERAL NOTES FIRE ALARM SYSTEM NOTES

1. THE DRAWINGS ARE GENERALLY DIAGRAMMATIC. PROVIDE A FIRE ALARM SYSTEM INSTALLATION THAT IS COMPLETE WITH ALL ITEMS AND APPURTENANCES NECESSARY, REASONABLE, INCIDENTAL, OR CUSTOMARILY INCLUDED, EVEN THOUGH EVERY ITEM IS NOT SPECIFICALLY SHOWN. PROVIDE ALL EQUIPMENT, MATERIALS, LABOR, SUPERVISION, AND SERVICE NECESSARY SO AS TO

PROVIDE A COMPLETE FUNCTIONING FIRE ALARM SYSTEM IN A SAFE WORKING ORDER.

2. SYMBOLS FOR VARIOUS ELEMENTS AND SYSTEMS ARE SHOWN ON THE DRAWINGS. SHOULD THERE BE ANY DOUBT REGARDING THE MEANING OR INTENT OF THE SYMBOLS USED, AN INTERPRETATION SHALL BE OBTAINED FROM THE OWNER/OWNER'S REPRESENTATIVE IN WRITING. THE DECISION OF THE OWNER'S REPRESENTATIVE SHALL BE FINAL.

3. EXAMINE THE CONTRACT DOCUMENTS CAREFULLY BEFORE SUBMITTING A BID, WITH PARTICULAR ATTENTION TO ERRORS, OMISSIONS, CONFLICTS WITH PROVISIONS OF LAWS AND CODES HAVING JURISDICTION, CONFLICTS BETWEEN DRAWINGS AND SPECIFICATIONS, AND AMBIGUOUS DEFINITION OF THE EXTENT OF COVERAGE BETWEEN CONTRACTS. ANY SUCH DISCREPANCY SHALL BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE OWNER/OWNER'S REPRESENTATIVE FOR CORRECTION. SHOULD ANY OF THESE ERRORS, OMISSIONS, CONFLICTS, OR AMBIGUITIES EXIST, THE CONTRACTOR SHALL HAVE THEM EXPLAINED AND ADJUSTED IN WRITING BEFORE SIGNING THE CONTRACT OR PROCEEDING WITH THE WORK; OTHERWISE HE SHALL AT HIS OWN EXPENSE SUPPLY THE PROPER MATERIALS AND LABOR TO MAKE GOOD ANY DAMAGE OR DEFECTS IN HIS WORK OR THE RESULTS

OBTAINED THEREFROM SUCH DISCREPANCY.

4. WHEREVER CONFLICTS OCCUR BETWEEN DIFFERENT PARTS OF THE CONTRACT DOCUMENTS, THE GREATER QUANTITY, THE BETTER QUALITY, OR LARGER SIZE SHALL PREVAIL UNLESS THE OWNER/OWNER'S REPRESENTATIVE INFORMS THE CONTRACTOR

OTHERWISE IN WRITING.

5. THE SCALE OF EACH DRAWING IS RELATIVELY ACCURATE; ANY DIMENSIONS SHOWN ARE APPROXIMATE TO CENTERLINE FROM ASSUMED BUILDING PERIMETER. THE CONTRACTOR SHALL OBTAIN THE NECESSARY DIMENSIONS FOR ANY EXACT TAKEOFFS FROM THE OWNER/OWNER'S REPRESENTATIVE. NO ADDITIONAL COST TO THE OWNER WILL BE CONSIDERED FOR FAILURE TO OBTAIN

EXACT DIMENSIONS WHERE NOT CLEAR OR IN ERROR ON THE DRAWINGS.

6. ANY DEVICE OR FIXTURE ROUGHED IN IMPROPERLY AND NOT POSITIONED ON IMPLIED CENTER LINES OR AS REQUIRED BY GOOD

PRACTICE MUST BE REPOSITIONED AT NO COST TO THE OWNER.

7. GUARANTEE ALL WORK AND MATERIALS FREE FROM DEFECTS FOR A MINIMUM PERIOD OF ONE YEAR UNLESS OTHERWISE NOTED.

THE WARRANTY PERIOD SHALL BEGIN AT THE DATE OF BENEFICIAL OCCUPANCY OF THE FACILITY.

8. ASSUME RESPONSIBILITY FOR FILING AND PAYING ALL FEES AND OBTAINING NECESSARY PERMITS AND CERTIFICATES OF INSPECTION. DELIVER ALL CERTIFICATES OF INSPECTION TO OWNER/CONSTRUCTION MANAGER INCLUDING COPIES WITH

MAINTENANCE MANUALS.

9. ONLY EXPERIENCED CRAFTSMEN KNOWLEDGEABLE IN THEIR RESPECTIVE TRADE SHALL PERFORM THE WORK DESCRIBED IN THE

CONSTRUCTION DOCUMENTS.

10. ALL WORK MUST BE DONE IN ACCORDANCE WITH UFC 3-600-01 AND THE LATEST ADOPTED EDITION OF NFPA 72.

11. ALL EQUIPMENT, INCLUDING BUT NOT LIMITED TO FIRE ALARM PANELS, DEVICES, CONDUIT, WIRE, BOXES, AND FITTINGS MUST MEET THE STANDARDS OF UFC 3-600-01 AND NFPA 72 AND MUST BE INSTALLED AS PART OF A LISTED SYSTEM.

12. SUBMIT SHOP DRAWINGS FOR REVIEW OF ALL EQUIPMENT, DEVICES, AND MATERIALS PROPOSED UNDER THIS CONTRACT. ANY DEVIATIONS FROM ITEMS SPECIFIED MUST BE CLEARLY IDENTIFIED AND SEPARATELY SUBMITTED WITH A FORMAL SUBSTITUTION REQUEST. DRAWINGS MUST BE SUBMITTED AND APPROVED BY THE OWNER/OWNER'S REPRESENTATIVE PRIOR TO SUBMISSION TO

THE LOCAL AUTHORITY

1. THE FIRE ALARM INITIATING DEVICES, INDICATING DEVICES, CONTROL/ANNUNCIATOR PANELS, AND OTHER PERIPHERAL DEVICES SHOWN ON THESE DOCUMENTS DO NOT CONSTITUTE THE TOTAL QUANTITY AND/OR TYPE OF DEVICES REQUIRED FOR THE PROJECT. THE EQUIPMENT INDICATED ON THESE DRAWINGS IS SHOWN FOR THE PURPOSE OF COORDINATION ONLY. THE FIRE ALARM CONTRACTOR MUST BE RESPONSIBLE FOR THE DESIGN, LAYOUT, AND INSTALLATION OF A COMPLETE SYSTEM IN ACCORDANCE WITH THE APPLICABLE CODES AND STANDARDS (INCLUDING THIRD PARTY LIFE SAFETY REPORTS), AND WITH THE REQUIREMENTS OF THE CONTRACTING OFFICER. THE SYSTEM DRAWINGS SHALL BE DESIGNED AND SEALED BY A NICET LEVEL III

CERTIFIED DESIGNER.

2. THE FIRE ALARM SYSTEM MUST BE IN ACCORDANCE WITH UFC 3-600-01.

3. THE FIRE ALARM REPORTING SYSTEM MUST CONFORM TO NFPA 72 AND NFPA 70. ALARM SIGNAL BY DEVICE TYPE, GENERAL SUPERVISORY SIGNAL, AND GENERAL TROUBLE SIGNAL MUST BE TRANSMITTED VIA THE FIRE ALARM REPORTING SYSTEM.

4. FURNISH AND INSTALL FIRE ALARM NOTIFICATION AND DETECTION IN ALL AREAS INDICATED ON THE DRAWINGS.

5. AUDIBLE AND VISIBLE NOTIFICATION APPLIANCES ARE SHOWN TO INDICATE WHICH ROOMS/AREAS REQUIRE COVERAGE. ACTUAL

NUMBER OF DEVICES AND RATINGS MUST BE THE CONTRACTOR'S RESPONSIBILITY.

6. SPEAKERS MUST BE PLACED TO MEET INTELLIGIBILITY REQUIREMENTS. ADDITIONAL DEVICES MAY BE NEEDED THROUGHOUT

SPACES DUE TO GEOMETRY AND BUILDING FINISHES.

7. PROVIDE SYNCHRONIZATION OF VISIBLE NOTIFICATION APPLIANCES.

8. VISUAL STROBE DEVICES MUST MEET THE REQUIREMENTS OF ABA, UL, UFC, AND NFPA. CLEAR STROBE LENSES MUST BE PROVIDED, IN ACCORDANCE WITH UFC 4-021-01.

9. PROVIDE DUCT SMOKE DETECTORS TO COORDINATE WITH THE MECHANICAL SYSTEM AS REQUIRED BY THE REFERENCED CODES AND STANDARDS, AND THE AUTHORITIES HAVING JURISDICTION. THIS INCLUDES BUT IS NOT LIMITED TO COORDINATION WITH AIR

HANDLING UNITS OVER 2,000 CFM AND SMOKE DAMPERS.

10. PROVIDE MODULES, POWER SUPPLIES, HARDWARE, SOFTWARE, ETC. TO THE FIRE ALARM SYSTEM IN ORDER TO ACCOMMODATE

THE ADDITIONAL FIRE ALARM DEVICES.

11. PROVIDE SURGE PROTECTION AT ALL POWER SUPPLY PANELS.

12. THE ENTIRE SYSTEM MUST BE TESTED TO THE OWNER'S SATISFACTION. THE CONTRACTOR MUST PROVIDE A COMPLETE REPORT FOR ALL NEW SMOKE, DUCT, AND HEAT DETECTORS. THE CONTRACTOR SHALL REPLACE ANY DETECTOR THAT DOES NOT MEET THE

SENSITIVITY VALUES.

13. THE CONTRACTOR MUST SUBMIT SIGNED AND SEALED PLANS INDICATING EXACT LOCATION, TYPE, CABLING, AND BATTERY CALCULATION TO THE OWNER/OWNER'S REPRESENTATIVE FOR APPROVAL BEFORE SUBMITTAL TO THE LOCAL AUTHORITY.

14. PROVIDE NEW CONDUIT AND WIRING AS REQUIRED FOR NEW FIRE ALARM DEVICES. CONNECT AND PROGRAM DEVICES TO NEW FIRE CONTROL PANEL. COORDINATE EXACT LOCATION OF THE FIRE CONTROL PANEL WITH THE OWNER. PROVIDE POWER SUPPLIES AS NECESSARY INCLUDING EXPANSION MODULES OR ANY SOFTWARE OR HARDWARE ACCESSORIES REQUIRED FOR A COMPLETE

AND FUNCTIONAL INSTALLATION. ALL DEVICES MUST MEET ABA REQUIREMENTS.

15. PROVIDE CLASS A PATHWAYS FOR ADDRESSABLE DETECTION, NOTIFICATION, AND SIGNALING LINE CIRCUITS.

16. ALL WIRING MUST BE COPPER AND IN CONDUIT. COLOR SHALL BE THE FACILITY'S STANDARD OR RED.

17. ALL SIGNALING LINE CIRCUITS MUST BE MINIMUM 18 AWG. INITIATING DEVICE AND NOTIFICATION APPLIANCE CIRCUITS MUST BE

MINIMUM 16 AWG.

18. ALL CONDUIT SHALL BE A MINIMUM 3/4-INCH.

19. UPON ACTIVATION OF THE DUCT DETECTOR THE AHU SHALL SHUT DOWN WHEN IN MANUAL OR AUTOMATIC POSITION. LOCATE THE

FIRE ALARM RELAY WITHIN 3 FEET OF THE STARTER.

21. THE CONSTRUCTION CONTRACTOR WILL COORDINATE WITH THE FIRE DEPARTMENT TO PROVIDE ALL ENGINEERING, PROJECT MANAGEMENT, MATERIALS, INSTALLATION, TESTING, AND DOCUMENTATION NECESSARY TO PROVIDE A FULLY OPERATIONAL IN- BUILDING DISTRIBUTED ANTENNA SYSTEM (DAS). UTILIZING THE EXISTING WIDE AREA COVERAGE SYSTEM, THE PROPOSED IN- BUILDING DISTRIBUTED ANTENNA SYSTEM WILL SIGNIFICANTLY ENHANCE THE POST EMERGENCY SERVICE TRUNKED LAND MOBILE RADIO (LMR) NETWORK COVERAGE TO THE FACILITY. THE SOLUTION WILL PROVIDE 95 PERCENT BUILDING COVERAGE, AT A DELIVERED AUDIO QUALITY (DAQ) OF 3.4 OR CIRCUIT MERIT 3 (CM3) LEVEL OF COVERAGE, OR BETTER.

MASS NOTIFICATION SYSTEM

ALL SYMBOLS SHOWN MAY

NOT APPEAR IN ALL

DRAWINGS. SYMBOLS ARE

SHOWN SCHEMATIC AND MAY

NOT BE TO SCALE.

WATER FLOW SWITCHWF

VALVE SUPERVISORY SWITCHVS

SMOKE DETECTOR WALL MOUNTED

SMOKE DETECTOR CEILING MOUNTED

DUCT SMOKE DETECTOR

FACP

HEAT DETECTOR WALL MOUNTED

HEAT DETECTOR CEILING MOUNTED

FIRE ALARM BELL

FIRE ALARM AND MASS NOTIFICATION CONTROL PANEL

FAA FIRE ALARM ANNUNCIATOR PANEL

NAC FIRE ALARM NOTIFICATION APPLIANCE POWER EXTENDER

FIRE ALARM PULL STATION WALL MOUNTEDF

FIRE ALARM COMBINATION SPEAKER/STROBE CEILING MOUNTED, X DENOTES

CANDELA RATING (15 cd ASSUMED UNLESS OTHERWISE NOTED)X

FIRE ALARM SPEAKER CEILING MOUNTED

FIRE ALARM STROBE CEILING MOUNTED, X DENOTES CANDELA RATING (15 cd

ASSUMED UNLESS OTHERWISE NOTED)

WP WEATHER PROOF

AIM

AOM

ADDRESSABLE INPUT MODULE

ADDRESSABLE OUTPUT MODULE

ETD EMERGENCY MESSAGE TEXTUAL DISPLAY

AMP FIRE ALARM AMPLIFIER

LEGEND

WATER FLOW METERFS

FIRE ALARM STROBE WALL MOUNTED, X DENOTES CANDELA RATING (15 cd

ASSUMED UNLESS OTHERWISE NOTED)

FIRE ALARM COMBINATION SPEAKER/STROBE SIGNAL WALL MOUNTED, X DENOTES

CANDELA RATING (15 cd ASSUMED UNLESS OTHERWISE NOTED)X

X

X

THE MASS NOTIFICATION SYSTEM SHALL BE PROVIDED IN ACCORDANCE WITH THE LATEST EDITION OF UFC 4-021-01.

THE MASS NOTIFICATION SYSTEM SHALL BE INTEGRATED WITH THE NEW ADDRESSABLE FIRE ALARM SYSTEM. THE SYSTEM SHALL CONSIST OF A MASS NOTIFICATION PANEL, BOOSTER PANELS, LOCAL OPERATING CONSOLES, SPEAKERS, STROBES, AND LED TEXT SIGNS AS REQUIRED FOR A COMPLETE WORKING SYSTEM IN ACCORDANCE WITH UFC 04-021-01.

A MONACO ALARM SYSTEM WILL BE INSTALLED IN BUILDING B785 TO ENSURE COMPATIBILITY WITH CAMPUS ALARM SYSTEM.

STROBES FOR BOTH FIRE AND MASS NOTIFICATION SIGNAL SHALL USE A CLEAR WHITE STROBE PER USACE ECB 2018-17. THE

STROBE SHALL BE LABELED "ALERT" PER UFC 3-600-01.

THE SYSTEM STATUS OF THE MASS NOTIFICATION SYSTEM SHALL BE MONITORED BY THE FIRE ALARM SYSTEM.

THE MASS NOTIFICATION SYSTEM IS ACTIVATED BY CONTACT CLOSURE MESSAGE ACTIVATION.

A. ACTIVATION VIA THE FIRE ALARM SYSTEM SHALL RESPOND WITH AN AUDIBLE VOICE EVACUATION MESSAGE, WITH VISUAL

NOTIFICATION USING CLEAR STROBES, AND WITH LED TEXT SIGNS.

B. ACTIVATION BY MEANS OF LOCAL OPERATOR CONSOLE SHALL CORRESPOND WITH PRE-SELECTED EVENTS SPECIFIED AS

PER PROJECT REQUIREMENTS.

C. EACH REMOTE LOCAL OPERATOR CONSOLE CAN ALSO PROVIDE LIVE AUDIBLE MESSAGES VIA A DEDICATED PUSH TO TALK

MICROPHONE LOCATED INSIDE THE LOCAL OPERATOR CONSOLE.

D. UTILIZE WEST POINT STANDARD ALERTS

THE MASS NOTIFICATION SYSTEM ACTIVATION SHALL TRIGGER A SPECIFIC TYPE OF NOTIFICATION BASED UPON MESSAGE BUTTON SELECTED. THE WEST POINT BASE-SPECIFIC STANDARD ALERTS SHALL BE UTILIZED. MESSAGE WORDING AND PRIORITY SEQUENCE SHALL BE OBTAINED FROM THE CONTRACTING OFFICER (OR FIRE PREVENTION PERSONNEL) AND INCORPORATED INTO

THE DESIGN.

PROVIDE MASS NOTIFICATION LED TEXTURAL DISPLAYS FOR NOTIFICATION OF THE EMERGENCY AT PRIMARY EGRESS POINTS. THE TEXTUAL DISPLAYS SHALL BE PROGRAMMABLE AND SHALL DISPLAY THE TITLE OF THE ACTIVATED MASS NOTIFICATION SYSTEM PRE-RECORDED VOICE MESSAGE BEING PLAYED, “ANNOUNCEMENT” FOR LIVE VOICE TRANSMISSION, AND “EVACUATE” FOR FIRE ALARM ACTIVATION. THE SYSTEM SHALL INTERFACE WITH THE PROGRAMMABLE SIGN CONTROLLER TO ACTIVATE THE PROPER MESSAGE. PROGRAM TEXT MESSAGES TO FLASH ON AND OFF AT THE SAME RATE AND SYNCHRONIZATION AS VISUAL FIRE ALARM

APPLIANCES.

LOCAL OPERATING CONSOLES (LOC) SHALL BE PROVIDED FOR USER INPUT PER UFC 4-021-01. THE PROPOSED LOCATION AND QUANTITY OF LOC’S SHALL BE PER UFC 4-021-01 AND SHOWN ON THE DESIGN DOCUMENTS FOR AHJ APPROVAL.

CARBON MONOXIDE DETECTOR CEILING MOUNTEDCO

1.

2.

3.

4.

5.

6.

7.

8.

9.

LOC LOCAL OPERATING CONSOLE

FIRE ALARM SPEAKER WALL MOUNTED

LT LOW TEMPERATURE SENSOR

DACT DIGITAL ALARM COMMUNICATOR TRANSMITTER

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

E

ER

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

SEAL

NOT FOR

CONSTRUCTIO

N

FA001

B785

FI

R

E

AL

AR

M

G

EN

ER

A

L N

O

TE

S

AN

D L

EG

EN

D S

W

ES

T

PO

IN

T, N Y

N

EW

Y O

R K

D

IS

TR

IC

T P.

S

AB

A

M . H

EN

R

IQ

U

E Z

S.

S

A

BA

N

AY

AG

A

M

L.

K

EL

LE

R

AU

G

U

ST

2, W

R 0E

W

-1 7-

D -0

FI

LE

N

AM

E;

R

TA

S U

BM

IS

SI

O

N A

U G

U

ST

2, D

EN

TA

C _M

EP

F_

R

.R V

T

R

EP

AI

R

B U

IL

D

IN

G

, D E

N

TA

C

W

SP

U S

A

3R D

S T

N W

W

AS

H

IN

G

TO

N , D

C

THE CONTRACTOR SHALL OBTAIN THE SERVICES OF 'C SQUARED, INC' FOR THE DESIGN AND BUILD REQUIREMENTS FOR THE DISTRIBUTED ANTENNA SYSTEM. THE DAS EQUIPMENT HARDWARE AND DISTRIBUTION EQUIPMENT WILL BE RACK MOUNTED IN THE TELECOMMUNICATIONS ROOM. FROM THE TELECOMM ROOM THE DAS SYSTEM SHALL BE DISTRIBUTED USING COAX CABLE TO EACH ANTENNAE. ' C SQUARED INC' SHALL BE RESPONSIBLE FOR DETERMINING THE QUANTITY OF ANTENNAS TO PROVIDE COVERAGE TO EACH AREA OF THE BUILDING. ALL REQUIRED CABLING, INTERIOR CEILING MOUNTED ANTENNAS, RACK MOUNTED DAS EQUIPMENT IN THE TELECOM ROOM, POWER OUTLETS AND BRANCH CIRCUITS TO PROVIDE A COMPLETELY FUNCTIONAL DAS SHALL BE PROVIDED. COTNRACTOR SHALL PROVIDE SYSTEM DESIGN, PROJECT MANAGEMENT, COORDINATION WITH LOCAL COMMERCIAL WIRELESS SERVICE PROVIDERS (WSP) AND WIRELESS (CELL)

EQUIOPMENT AND SYSTEMS TO ENSURE FULL FUNCTIONALITY OF THE INSTALLED DAS.

A M

E N

D M

E N

T

NTS

H5 CABLE TRAY CLEARANCE DETAIL

PROVIDE MINIMUM 12"

CLEAR SPACE ABOVE

CABLE TRAY EXCEPT

WHERE CROSSING UNDER

STRUCTURE, PIPING OR

DUCT WORK.

CABLE TRAY.

#6 COPPER

INSULATED

GROUND

LADDER CABLE TRAY.

LADDER CABLE TRAY.

LADDER CABLE TRAY.

#6 COPPER INSULATED

GROUND

LADDER CABLE TRAY.

NOTE:

1. REFER TO PLANS CABLE TRAY FLOOR PLANS FOR SIZE AND

LOCATION OF LADDER CABLE TRAY.

NOTE:

1. REFER TO CABLE TRAY FLOOR PLANS FOR SIZE AND

LOCATION.

NTS

H13

EQUIPMENT

MOUNTING DETAIL

NTS

E1

CABLE TRAY

GROUNDING AND

CHANGE IN ELEVATION DETAIL

DESK TOP

FINISHED FLOOR

KNEE SPACE

FOURPLEX OUTLET

TELECOMMUNICATION OUTLET

TYPICAL #J1/T-503

3"-6" MAX

FROM

TERMINATION

RM-SEAT

C9

WRAP

AROUND LABEL DETAILC5

TYPICAL VOICE/DATA

OUTLET DETAIL

" M

IN

NTS NTS

" M

AX

24" MAX.

" M

AX

" M

AX

S

ID

E

AP

PR

O

AC

H

" M

AX

F R

O N

T

AP

PR

O

AC

H

TOP OF

CONTROL

SWITCH

OUTLET

FINISHED

FLOOR

TOP OF

CONTROL

FINISHED

FLOOR15

3"

CONCRETE

ENCASEMENT

3"

3"

3"

3"

NOTE:

1. REFER TO PLANS FOR SIZE AND QUANTITIES OF CONDUITS.

FINISHED GRADE

6" ORANGE METALLIC

TELECOMMUNICATIONS

WARNING TAPE

COMPACT TO 90% WITH

NATIVE SOIL

C13 TYPICAL TELECOM TRENCH SECTION

NTS

CABLE GUIDE 'WATER

FALL'.

SECTION

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

SEAL

R

EP

AI

R

B U

IL

D

IN

G

, D

EN

TA

C

N

EW

Y O

R K

D

IS

TR

IC

T R

. V

EN

G

EL

EN

S.

G

AR

C

IA

M . R

IZ

ZA

JU

LY

, 2

W

R 0E

W

-1 7-

D -0

FI

LE

N

AM

E:

R

TA

S U

BM

IS

SI

O

N A

U G

U

ST

2, W

ES

T

PO

IN

T, N Y

S.

S

AB

AN

AY

AG

AM

B785

W

SP

U

SA

3R D

S T

N W

W

AS

H

IN

G

TO

N , D

C

Michael Rizza

BICSI ID #337128

•REGIS

TE

RE

D

CO

MMUNICATIONS DISTRIBUTION

DESIGNER

R C D D

EXPIRES 12-31-22

T-501

TE

LE

C O

M M

U N

IC

AT

IO

N

S D

ET

AI

LS

T -5

T

EL

EC

O M

M U

N

IC

AT

IO

N S

D

ET

AI

LS

.D W

G

Michael Rizza

BICSI ID #337128

•REGIS

TE

RE

D

CO

MMUNICATIONS DISTRIBUTION

DESIGNER

R C D D

EXPIRES 12-31-22

Sheets
M-601 - MECHANICAL SCHEDULES
P-601 - PLUMBING SCHEDULES
PG104 - PLUMBING FIRST FLOOR DENTAL GAS PLAN AREA D