AFD0DC-1.PDF

PDF 791 KB Posted

Attached to
PA 206 HORSHAM HVAC SYSTEMS REPAIRS
Solicitation number
W912BU24R0001
Issued by

About this file

This document contains construction drawings and specifications for repairs to HVAC systems at the PA 206 Horsham facility. The project involves replacing air handling units, ductwork, controls, and other HVAC components. The solicitation was issued by the U.S. Army Corps of Engineers Philadelphia District on behalf of the Department of the Army. Interested parties can submit offers in response to solicitation number W912BU24R0001 by the specified closing date. The scope of work and technical requirements are detailed in the drawings and specifications to ensure the HVAC upgrades meet applicable building codes and industry standards.

View the file

Other files

File Type Posted
W912BU24R0001 Amendment 0009_Cancellation.pdf PDF
W912BU24R0001 Amendment 0005.pdf PDF
AFC015-1.PDF PDF
AF7200-1.PDF PDF
AF7DA6-1.PDF PDF
AF47CB-1.PDF PDF
AF0F76-1.PDF PDF
AF2040-1.PDF PDF
AFRC55-1.PDF PDF
00-MP-1.PDF PDF
10-M-802.pdf PDF
AF43EA-1.PDF PDF
AF97A7-1.PDF PDF
00-M-801.pdf PDF
AFD13B-1.PDF PDF
AFF300-1.PDF PDF
00-M-808.pdf PDF
AF1533-1.PDF PDF
AF2872-1.PDF PDF
00-MH-2.PDF PDF
AF7BD0-1.PDF PDF
00-M-201.pdf PDF
AF9D55-1.PDF PDF
00-M-602.pdf PDF
AF0EF7-1.PDF PDF
AF4E85-1.PDF PDF
AF1DF0-1.PDF PDF
AFFC93-1.PDF PDF
10-MH-1.PDF PDF
AF69FD-1.PDF PDF
AFF200-1.PDF PDF
00-M-806.pdf PDF
AF54B2-1.PDF PDF
AFFC3F-1.PDF PDF
AF377B-1.PDF PDF
00-MP-2.PDF PDF
AF9D68-1.PDF PDF
AFC2EA-1.PDF PDF
AF1E68-1.PDF PDF
AFA040-1.PDF PDF
10-M-800.pdf PDF
AF8467-1.PDF PDF
AFFB36-1.PDF PDF
AF5A0C-1.PDF PDF
10-M-804.pdf PDF
AF970C-1.PDF PDF
AFRC55-3.PDF PDF
00-M-807.pdf PDF
AF0467-1.PDF PDF
AF2EB8-1.PDF PDF
Show 40 more

Latest 50 of 108 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

00-A-303 1/2" = 1’-0"

A3

WALL SECTION

1/2" = 1’-0" A1

WALL SECTION

T R

A

IN

IN

G C

E N

T E

R W

A L L S

E C

T

IO

N S

2’ 4’0 1’

SCALE:1/2"=1’-0"

2’ 4’0 1’

SCALE:1/2"=1’-0"

AS-BUILT

S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5500-A-303.dgn

9/11/2012

9:23:01 AM

rifem

F O

R U

M S

T U

D

IO

I

N N

E R

B E

L T B

U S

IN

E S

S C

E N

T E

R D

R

S T L

O U

IS

M O

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

SHEET

IDENTIFICATION

D A

T E

A P

P R

SHEET OF

fi

US Army Corps of Engineers

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

L O

U

IS

V

IL

L E D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K Y

F S

B A

Z

C L

A Y

C O C

O N

S T

R U

C T

IO

N

.1

.1

-W

Q R -0

-R -0

P -1

1 3

C O

N C

E P

T D

E S

IG

N S

U B

M

IT

T A

L .1

.0

.1

.0

R

E V

IS

E D C

H A

R R

E T

T E C

O N

C E

P T S

U B

M

IT

T A

L

IN

T

E R

IM

S

U B

M

IT

T A

L .1

.1

.2

.1

A F

R C

-A -3

.d g n

/1

/2

F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L

A R

M Y R

E S

E R

V E T

R A

IN

IN

G C

E N

T E

R W

IL

L O

W G

R O

V E N

A V

A L A

IR

S

T A

T

IO

N W

Q R -0

-C -0

H O

R S

H A

M P

A

C

O R

R E

C T

E D F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L .0

.1

.1

.1

C

E R

T

IF

IE

D F

IN

A L S

U B

M

IT

T A

L

B R

IC

E Z

IC

K U

H R

100’-0"

1ST FLOOR

T.O. STEEL

126’-2"

114’-0"

2ND FLOOR

1’-8" 5’-0"

1’-8"

T.O. WALL

115’-4"

115’-4"

T.O. WALL

2ND FLOOR

114’-0"

126’-2"

T.O. STEEL

100’-0"

1ST FLOOR

41’-4"

1’-8"

1’-8" 5’-0"

B A 2 1

2 2

13 13

15 15

14’-8"

00-A-521

00-A-531

00-A-701

A4

A5

C4

B3

OPP

A5

TYP.

TYP.

54 54

112’-0"

T.O. STEEL

111’-6 7/8"

T.O. STEEL

A2

00-A-533

SIM.

CLOSURE

SHINGLE ROOFING

RIGID ROOF INSULATION (R-30)

METAL ROOF DECK

WOOD BLOCKING

RIGID INSULATION (R-12.5)

6" METAL STUDS AT 16" O.C.

BATT INSULATION (R-19)

EXTERIOR GYPSUM SHEATHING

BRICK VENEER

CONCRETE SLAB ON GRADE

8" CMU

STEEL LINTEL

SCHEDULED CEILING

METAL FURRING CHANNEL

5/8" GYPSUM BOARD

PERIMETER INSULATION (R-10)

SECTIONAL OVERHEAD DOOR

METAL COPING

H.M. DOOR AND FRAME

MASONRY TIES AT 16" O.C.

METAL ROOF PANELS

METAL ROOF PURLIN

ROOF INSULATION

METAL WALL PANELS

EAVE STRUT

WALL INSULATION

STEEL BASE ANGLE

BASE CLOSURE

STEEL FRAME BEYOND

ENDWALL POST BEYOND

CONTOUR GABLE TRIM

CAP FLASHING

SHEET NOTES

HALF HEIGHT MASONRY

STARTER COURSE

STEEL GRATE PLATFORM -

SEE STRUCTURAL

FIRE TREATED OSB EXTERIOR

SHEATHING

CONCRETE SLAB W/ METAL DECK -

SEE STRUCTURAL DRAWINGS

CONCRETE FOUNDATION -

SEE STRUCTURAL DRAWINGS

ALUMINUM STORE FRONT

W/ LAMINATED INSULATING GLASS

STEEL BEAM -

SEE STRUCTURAL DRAWINGS

STEEL JOIST -

SEE STRUCTURAL DRAWINGS

METAL SIDEWALL GIRT

VAPOR BARRIER

PRE-FINISHED SHEET MTL. FASCIA

PANEL WITH STIFFENING RIBS

STL. ANGLE CLIP: SEE STRUCT.

PRE-FINISHED SHEET MTL. WALL

PANEL

ALUMINUM SUPPORT ANGLE - SEE

STRUCTURAL

PRE-ENGINEERED CANOPY WITH

METAL DOWN SPOUT

SEE DETAILS A4 AND C4 ON SHEET

00-A-533

6"X6" METAL GUTTER WITH 4"X5"

DOWN SPOUT

METAL OVERFLOW SCUPPER WITH

6"X6" DOWNSPOUT:

SEE C5 / D5 ON SHEET 00-A-531

STL. FRAME MAIN ENTRY CANOPY

METAL LINER PANEL

LOUVER - SEE MECHANICAL

OPENING FOR MECHANICAL

EQUIPMENT - SEE MECHANICAL

SPLIT FACED CMU VENEER - USE

SMOOTH FACE AT CANOPIES

EPDM MEMBRANE ROOFING

EPDM MEMBRANE ROOFING ON

TAPERED INSULATION

COLUMN BEYOND

LIGHT GA. CLIP WITH SLIP

CONNECTION

BOND BEAM

AIR SPACE - 1 1/2" MIN.

VENTED METAL SOFFIT PANEL

CONTINUOUS AIR AND MOISTURE

BARRIER SYSTEM (A.M.B.S.)

PRE-FINISHED ALUMINUM LOUVER

REFER TO LOUVER SCHEDULE

ON SHEET 00-A-602

PRECAST CONCRETE SILL

66 FIXED ALUMINUM WINDOW

PARTIAL HEIGHT WALL PER

FLOOR PLAN. RETURN TOP

OF WALL TO EXTERIOR WALL

File details come from the government source that posted it. Updated .