About this file

This document contains architectural drawings and notes for roof repairs and HVAC system upgrades at the Army Reserve Training Center in Horsham, Pennsylvania. The drawings depict the existing roof plan and include details on asphalt shingle roofing, EPDM membrane roofing, gutters, downspouts, vents, and flashing. Specified work also involves tapered insulation, continuous ridge vents, and radon vents. The related federal contract opportunity is solicitation number W912BU24R0001 from the Department of the Army Corps of Engineers Engineering District Philadelphia for HVAC system repairs at the PA 206 facility in Horsham. Products and services required include roof repairs and HVAC upgrades, as depicted in the architectural drawings.

View the file

Other files

File Type Posted
W912BU24R0001 Amendment 0009_Cancellation.pdf PDF
W912BU24R0001 Amendment 0005.pdf PDF
AFC015-1.PDF PDF
AF7200-1.PDF PDF
AF7DA6-1.PDF PDF
AF47CB-1.PDF PDF
AF0F76-1.PDF PDF
AF2040-1.PDF PDF
AFRC55-1.PDF PDF
00-MP-1.PDF PDF
10-M-802.pdf PDF
AF43EA-1.PDF PDF
AF97A7-1.PDF PDF
00-M-801.pdf PDF
AFD13B-1.PDF PDF
00-M-808.pdf PDF
AF1533-1.PDF PDF
AF2872-1.PDF PDF
00-MH-2.PDF PDF
AF7BD0-1.PDF PDF
00-M-201.pdf PDF
AF9D55-1.PDF PDF
00-M-602.pdf PDF
AF0EF7-1.PDF PDF
AF4E85-1.PDF PDF
AF1DF0-1.PDF PDF
AFFC93-1.PDF PDF
10-MH-1.PDF PDF
AF69FD-1.PDF PDF
AFF200-1.PDF PDF
00-M-806.pdf PDF
AF54B2-1.PDF PDF
AFFC3F-1.PDF PDF
AF377B-1.PDF PDF
00-MP-2.PDF PDF
AF9D68-1.PDF PDF
AFC2EA-1.PDF PDF
AF1E68-1.PDF PDF
AFA040-1.PDF PDF
10-M-800.pdf PDF
AF8467-1.PDF PDF
AFFB36-1.PDF PDF
AF5A0C-1.PDF PDF
10-M-804.pdf PDF
AF970C-1.PDF PDF
AFRC55-3.PDF PDF
00-M-807.pdf PDF
AF0467-1.PDF PDF
AF2EB8-1.PDF PDF
AF400F-1.PDF PDF
Show 40 more

Latest 50 of 108 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

00-A-121

1/16" = 1’ 0" A4

OVERALL ROOF PLAN

T R

A

IN

IN

G C

E N

T E

R O

V E

R A

L L R

O O

F P

L A

N

AS-BUILT

S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5500-A-121.dgn

9/11/2012

9:21:45 AM

rifem

F O

R U

M S

T U

D

IO

I

N N

E R

B E

L T B

U S

IN

E S

S C

E N

T E

R D

R

S T L

O U

IS

M O

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

SHEET

IDENTIFICATION

D A

T E

A P

P R

SHEET OF

fi

US Army Corps of Engineers

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

L O

U

IS

V

IL

L E D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K Y

GENERAL NOTES

KEY PLAN

KEY NOTES

GRAPHIC SCALE

32’8’

SCALE:1/16"=1’

0 16’

F S

B A

Z

C L

A Y

C O C

O N

S T

R U

C T

IO

N

.1

.1

-W

Q R -0

-R -0

P -1

1 3

C O

N C

E P

T D

E S

IG

N S

U B

M

IT

T A

L .1

.0

.1

.0

R

E V

IS

E D C

H A

R R

E T

T E C

O N

C E

P T S

U B

M

IT

T A

L

IN

T

E R

IM

S

U B

M

IT

T A

L .1

.1

.2

.1

A F

R C

-A -1

.d g n

/1

/2

F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L

A R

M Y R

E S

E R

V E T

R A

IN

IN

G C

E N

T E

R W

IL

L O

W G

R O

V E N

A V

A L A

IR

S

T A

T

IO

N W

Q R -0

-C -0

H O

R S

H A

M P

A

C

O R

R E

C T

E D F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L .0

.1

.1

.1

C

E R

T

IF

IE

D F

IN

A L S

U B

M

IT

T A

L

B R

IC

E Z

IC

K U

H R

00-A-532

C4

4 4

7 7 77 7 7 7

7777777

00-A-533

A2

TYP

TYP.

00-A-532

A3

TYP.

00-A-532

A2

TYP.

00-A-533

00-A-531

A2

SIM

00-A-531

A2

2’-0"2’-0"2’-0"2’-0"2’-0"

8 8 8 8 86

6 66 00-A-531

C4

00-A-531

C4

TYP.

TYP.

9 99 9

1’-0" TO RIDGE1’-0" TO RIDGE

A2

SIM.

SLOPE

4:12

SLOPE

4:12

SLOPE

4:12

S L

O P

E /2

SLOPE

4:12

SLOPE

4:12

S L

O P

E /2

S L

O P

E /2

S L

O P

E /2

S L

O P

E /2

SLOPE

4:12

SLOPE

4:12

SLOPE

4:12

S L

O P

E :1

S

L O

P E

:1

SLOPE

1/2":12

SLOPE

1/2":12

PLAN

NORTH

S L

O P

E /2

S L

O P

E /2

S L

O P

E /2

SLOPE

1/2":12

SLOPE

1/2":12

SLOPE

1/2":12

SLOPE

1/2":12

SLOPE

1/2":12

SLOPE

1/2":12

SLOPE

1/2":12

SLOPE

1/2":12

SLOPE @ LOW ROOF

1/2":12

PREFINISHED METAL GUTTER, 6"x6"

PREMANUFACTURED CANOPY

CRICKET

ASPHALT SHINGLE ROOFING

DOWN SPOUT, 4"x5"

PIPE VENT: SEE FLASHING DETAIL "B4" ON SHEET 00-A-532

EPDM MEMBRANE ROOFING

PREFINISHED METAL COPING: SEE DETAILS "D1" ON SHEET 00-A-531 AND

"C2" ON SHEET 00-A-532 FOR FLASHING CONDITIONS AT WALL TERMINATION

METAL SCUPPER AND OVERFLOW WITH 6"x6" DOWN SPOUT

SEE DETAILS "C5" AND "D5" ON SHEET 00-A-531

EPDM MEMBRANE ROOFING ON TAPERED INSULATION

CONTINUOUS RIDGE VENT FLAT / SLOPE

CONTINUOUS RIDGE VENT

13 RADON VENT

329’-4"

40’-8"34’-4"7’-0"34’-2"26’-6"14’-8"41’-2"41’-2"27’-11 1/4 "9’-3 3/4 "12’-4 5/8 "25’-4 1/2 "14’-8"

11 11

12 12 12

1 2 3 3.2 4 5 6 6.4 7 7.8 8 9 102.7

A

B

C

D

D.1

E

D.6

GENERAL NOTES

KEY NOTES

GRAPHIC SCALE

32’8’

SCALE:1/16"=1’

0 16’

File details come from the government source that posted it. Updated .