AF97A7-1.PDF
PDF 794 KB Posted
- Attached to
- PA 206 HORSHAM HVAC SYSTEMS REPAIRS
- Solicitation number
- W912BU24R0001
About this file
This document contains construction plans for repairs to the HVAC systems at the PA 206 Horsham Army Reserve Training Center in Horsham, Pennsylvania. The solicitation is identified as number W912BU24R0001 and is being conducted by the Department of the Army Corps of Engineers Engineering District Philadelphia. The plans include enlarged floor plans, sections, and details for repairs and upgrades to the HVAC systems in the training center and OMS/AMSA buildings. The plans indicate locations for dehumidifiers, plumbing fixtures, rifle racks, fire extinguishers, intrusion detection systems, and other HVAC equipment. Dimensions and specifications are provided for concrete walls, doors, and other construction elements. Notes provide instructions regarding partition types and locations, corner guards, furniture layouts, mounting heights, and finish schedules.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W912BU24R0001 Amendment 0009_Cancellation.pdf | ||
| W912BU24R0001 Amendment 0005.pdf | ||
| AFC015-1.PDF | ||
| AF7200-1.PDF | ||
| AF7DA6-1.PDF | ||
| AF47CB-1.PDF | ||
| AF0F76-1.PDF | ||
| AF2040-1.PDF | ||
| AFRC55-1.PDF | ||
| 00-MP-1.PDF | ||
| 10-M-802.pdf | ||
| AF43EA-1.PDF | ||
| 00-M-801.pdf | ||
| AFD13B-1.PDF | ||
| AFF300-1.PDF | ||
| 00-M-808.pdf | ||
| AF1533-1.PDF | ||
| AF2872-1.PDF | ||
| 00-MH-2.PDF | ||
| AF7BD0-1.PDF | ||
| 00-M-201.pdf | ||
| AF9D55-1.PDF | ||
| 00-M-602.pdf | ||
| AF0EF7-1.PDF | ||
| AF4E85-1.PDF | ||
| AF1DF0-1.PDF | ||
| AFFC93-1.PDF | ||
| 10-MH-1.PDF | ||
| AF69FD-1.PDF | ||
| AFF200-1.PDF | ||
| 00-M-806.pdf | ||
| AF54B2-1.PDF | ||
| AFFC3F-1.PDF | ||
| AF377B-1.PDF | ||
| 00-MP-2.PDF | ||
| AF9D68-1.PDF | ||
| AFC2EA-1.PDF | ||
| AF1E68-1.PDF | ||
| AFA040-1.PDF | ||
| 10-M-800.pdf | ||
| AF8467-1.PDF | ||
| AFFB36-1.PDF | ||
| AF5A0C-1.PDF | ||
| 10-M-804.pdf | ||
| AF970C-1.PDF | ||
| AFRC55-3.PDF | ||
| 00-M-807.pdf | ||
| AF0467-1.PDF | ||
| AF2EB8-1.PDF | ||
| AF400F-1.PDF |
Show 40 more
Latest 50 of 108 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
00-A-403 1/4" = 1’-0"
A4
ENLARGED PLAN
D3 1/4" = 1’-0"1/4" = 1’-0"
D1
C1 1/4" = 1’-0"
SECTION AT VAULT
SECTION AT VAULT
SECTION AT VAULT
AS-BUILT
T R
A
IN
IN
G C
E N
T E
R E
N L
A R
G E
D P
L A
N S
S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5500-A-403.dgn
9/11/2012
9:24:02 AM
rifem
F O
R U
M S
T U
D
IO
I
N N
E R
B E
L T B
U S
IN
E S
S C
E N
T E
R D
R
S T L
O U
IS
M O
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
fi
US Army Corps of Engineers
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S I
D
L O
U
IS
V
IL
L E D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K Y
4’ 8’0 2’
SCALE:1/4"=1’
F S
B A
Z
C L
A Y
C O C
O N
S T
R U
C T
IO
N
.1
.1
-W
Q R -0
-R -0
P -1
1 3
C O
N C
E P
T D
E S
IG
N S
U B
M
IT
T A
L .1
.0
.1
.0
R
E V
IS
E D C
H A
R R
E T
T E C
O N
C E
P T S
U B
M
IT
T A
L
IN
T
E R
IM
S
U B
M
IT
T A
L .1
.1
.2
.1
A F
R C
-A -4
.d g n
/1
/2
F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L
A R
M Y R
E S
E R
V E T
R A
IN
IN
G C
E N
T E
R W
IL
L O
W G
R O
V E N
A V
A L A
IR
S
T A
T
IO
N W
Q R -0
-C -0
H O
R S
H A
M P
A
C
O R
R E
C T
E D F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L .0
.1
.1
.1
C
E R
T
IF
IE
D F
IN
A L S
U B
M
IT
T A
L
B R
IC
E Z
IC
K U
H R
6.4 7
B
116B
VAULT
10’-5"12’-11" 8’-7" 2’-6"
12’-11"
/8
/8
116A
ARMORY
116A.2
5’-8"5’-8" 4"
/2
/2
5’-8"5’-8"4"
5’-8" 5’-8" 4"
/2
/2
10 1/8 "
PLAN
NORTH
TYP.
TYP.
DEHUMIDIFIER, PLUMBER TO PROVIDE FLOOR DRAIN
CAST-IN-PLACE FLOOR ANCHORS - NEENAH MOORING EYE R-3490 OR EQUAL
RIFLE RACKS: GFGI
SHOWN FOR LOCATION PURPOSES
WIRE MESH CAGE WALLS AND DOORS INSTALLED FLOOR TO CEILING
FIRE EXTINGUISHER (BRACKET MOUNTED)
CONCRETE CAST IN PLACE WALLS, SEE STRUCTURAL FOR DIMENSIONS
INTRUSION DETECTION SYSTEM PANEL
A .1
/2
/2
/2
/2
/2
/2
/2
/2
C L
C L
C L
C L
C L
C L
C L
3’-11"3’-0"3’-0"3’-0"
C L
C L
C L
C L
SLIDE
DIRECTION
SLIDE
DIRECTION
SLIDE
DIRECTION
SLIDE
DIRECTION
SLIDE
DIRECTION
SLIDE
DIRECTION
SLIDE
DIRECTION
PADLOCK LUG WELDED TO
SLIDING DOOR FRAME
PROVIDE CORRESPONDING
LUG WELDED TO CAGE POST
(TYP)
STEEL U BRACKET
PADLOCK LUG WELDED TO
SLIDING DOOR FRAME
PROVIDE CORRESPONDING
LUG WELDED TO CAGE POST
(TYP)
STEEL U BRACKET
100’-0"
FIRST FLOOR
110’-0"
T.O. VAULT
00-A-402
A2A2
00-A-402
00-A-402
A2
PADLOCK LUG WELDED TO
SLIDING DOOR FRAME
PROVIDE CORRESPONDING
LUG WELDED TO CAGE POST
(TYP)
STEEL U BRACKET
SIM.
SIM. SIM.
D3
D1
C1
COLUMN BEYOND
00-A-402
D2
D4
D1
COLUMN BEYOND
1. ALL PARTITIONS ON THE FIRST FLOOR OF THE TRAINING BUILDING
TO BE TYPE 2A / S, SW. U.N.O.
2. ALL PARTITIONS ON THE SECOND FLOOR OF THE TRAINING
BUILDING TO BE TYPE 2A / T @ 10’-0", SW. U.N.O.
3. ALL PARTITIONS IN THE OMS / AMSA BUILDING TO BE TYPE 2A / S,
SW. U.N.O.
4. INSTALL POLYVINYL CORNER GUARDS 6" A.F.F. TO 6" BELOW THE
CEILING WHERE INDICATED ON THE PLAN FOR ALL PUBLIC
SPACES.
5. SEE THE INTERIOR DRAWINGS FOR ALL FURNITURE AND
EQUIPMENT LAYOUTS.
6. DIMENSIONS ARE TO COLUMN LINES, FACE OF MASONRY, OR FACE
OF GYP.
7. SEE TYPICAL MOUNTING HEIGHTS ELEVATION ON 00-G-003 AND
00-A-500.
8. SEE FINISH SCHEDULE AND FINISH PLANS FOR ALL FINISH INFO.
4’ 8’0 2’
SCALE:1/4"=1’
GENERAL NOTES
GRAPHIC SCALE
KEY NOTES
File details come from the government source that posted it. Updated .