AF97A7-1.PDF

PDF 794 KB Posted

Attached to
PA 206 HORSHAM HVAC SYSTEMS REPAIRS
Solicitation number
W912BU24R0001
Issued by

About this file

This document contains construction plans for repairs to the HVAC systems at the PA 206 Horsham Army Reserve Training Center in Horsham, Pennsylvania. The solicitation is identified as number W912BU24R0001 and is being conducted by the Department of the Army Corps of Engineers Engineering District Philadelphia. The plans include enlarged floor plans, sections, and details for repairs and upgrades to the HVAC systems in the training center and OMS/AMSA buildings. The plans indicate locations for dehumidifiers, plumbing fixtures, rifle racks, fire extinguishers, intrusion detection systems, and other HVAC equipment. Dimensions and specifications are provided for concrete walls, doors, and other construction elements. Notes provide instructions regarding partition types and locations, corner guards, furniture layouts, mounting heights, and finish schedules.

View the file

Other files

File Type Posted
W912BU24R0001 Amendment 0009_Cancellation.pdf PDF
W912BU24R0001 Amendment 0005.pdf PDF
AFC015-1.PDF PDF
AF7200-1.PDF PDF
AF7DA6-1.PDF PDF
AF47CB-1.PDF PDF
AF0F76-1.PDF PDF
AF2040-1.PDF PDF
AFRC55-1.PDF PDF
00-MP-1.PDF PDF
10-M-802.pdf PDF
AF43EA-1.PDF PDF
00-M-801.pdf PDF
AFD13B-1.PDF PDF
AFF300-1.PDF PDF
00-M-808.pdf PDF
AF1533-1.PDF PDF
AF2872-1.PDF PDF
00-MH-2.PDF PDF
AF7BD0-1.PDF PDF
00-M-201.pdf PDF
AF9D55-1.PDF PDF
00-M-602.pdf PDF
AF0EF7-1.PDF PDF
AF4E85-1.PDF PDF
AF1DF0-1.PDF PDF
AFFC93-1.PDF PDF
10-MH-1.PDF PDF
AF69FD-1.PDF PDF
AFF200-1.PDF PDF
00-M-806.pdf PDF
AF54B2-1.PDF PDF
AFFC3F-1.PDF PDF
AF377B-1.PDF PDF
00-MP-2.PDF PDF
AF9D68-1.PDF PDF
AFC2EA-1.PDF PDF
AF1E68-1.PDF PDF
AFA040-1.PDF PDF
10-M-800.pdf PDF
AF8467-1.PDF PDF
AFFB36-1.PDF PDF
AF5A0C-1.PDF PDF
10-M-804.pdf PDF
AF970C-1.PDF PDF
AFRC55-3.PDF PDF
00-M-807.pdf PDF
AF0467-1.PDF PDF
AF2EB8-1.PDF PDF
AF400F-1.PDF PDF
Show 40 more

Latest 50 of 108 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

00-A-403 1/4" = 1’-0"

A4

ENLARGED PLAN

D3 1/4" = 1’-0"1/4" = 1’-0"

D1

C1 1/4" = 1’-0"

SECTION AT VAULT

SECTION AT VAULT

SECTION AT VAULT

AS-BUILT

T R

A

IN

IN

G C

E N

T E

R E

N L

A R

G E

D P

L A

N S

S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5500-A-403.dgn

9/11/2012

9:24:02 AM

rifem

F O

R U

M S

T U

D

IO

I

N N

E R

B E

L T B

U S

IN

E S

S C

E N

T E

R D

R

S T L

O U

IS

M O

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

SHEET

IDENTIFICATION

D A

T E

A P

P R

SHEET OF

fi

US Army Corps of Engineers

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

L O

U

IS

V

IL

L E D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K Y

4’ 8’0 2’

SCALE:1/4"=1’

F S

B A

Z

C L

A Y

C O C

O N

S T

R U

C T

IO

N

.1

.1

-W

Q R -0

-R -0

P -1

1 3

C O

N C

E P

T D

E S

IG

N S

U B

M

IT

T A

L .1

.0

.1

.0

R

E V

IS

E D C

H A

R R

E T

T E C

O N

C E

P T S

U B

M

IT

T A

L

IN

T

E R

IM

S

U B

M

IT

T A

L .1

.1

.2

.1

A F

R C

-A -4

.d g n

/1

/2

F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L

A R

M Y R

E S

E R

V E T

R A

IN

IN

G C

E N

T E

R W

IL

L O

W G

R O

V E N

A V

A L A

IR

S

T A

T

IO

N W

Q R -0

-C -0

H O

R S

H A

M P

A

C

O R

R E

C T

E D F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L .0

.1

.1

.1

C

E R

T

IF

IE

D F

IN

A L S

U B

M

IT

T A

L

B R

IC

E Z

IC

K U

H R

6.4 7

B

116B

VAULT

10’-5"12’-11" 8’-7" 2’-6"

12’-11"

/8

/8

116A

ARMORY

116A.2

5’-8"5’-8" 4"

/2

/2

5’-8"5’-8"4"

5’-8" 5’-8" 4"

/2

/2

10 1/8 "

PLAN

NORTH

TYP.

TYP.

DEHUMIDIFIER, PLUMBER TO PROVIDE FLOOR DRAIN

CAST-IN-PLACE FLOOR ANCHORS - NEENAH MOORING EYE R-3490 OR EQUAL

RIFLE RACKS: GFGI

SHOWN FOR LOCATION PURPOSES

WIRE MESH CAGE WALLS AND DOORS INSTALLED FLOOR TO CEILING

FIRE EXTINGUISHER (BRACKET MOUNTED)

CONCRETE CAST IN PLACE WALLS, SEE STRUCTURAL FOR DIMENSIONS

INTRUSION DETECTION SYSTEM PANEL

A .1

/2

/2

/2

/2

/2

/2

/2

/2

C L

C L

C L

C L

C L

C L

C L

3’-11"3’-0"3’-0"3’-0"

C L

C L

C L

C L

SLIDE

DIRECTION

SLIDE

DIRECTION

SLIDE

DIRECTION

SLIDE

DIRECTION

SLIDE

DIRECTION

SLIDE

DIRECTION

SLIDE

DIRECTION

PADLOCK LUG WELDED TO

SLIDING DOOR FRAME

PROVIDE CORRESPONDING

LUG WELDED TO CAGE POST

(TYP)

STEEL U BRACKET

PADLOCK LUG WELDED TO

SLIDING DOOR FRAME

PROVIDE CORRESPONDING

LUG WELDED TO CAGE POST

(TYP)

STEEL U BRACKET

100’-0"

FIRST FLOOR

110’-0"

T.O. VAULT

00-A-402

A2A2

00-A-402

00-A-402

A2

PADLOCK LUG WELDED TO

SLIDING DOOR FRAME

PROVIDE CORRESPONDING

LUG WELDED TO CAGE POST

(TYP)

STEEL U BRACKET

SIM.

SIM. SIM.

D3

D1

C1

COLUMN BEYOND

00-A-402

D2

D4

D1

COLUMN BEYOND

1. ALL PARTITIONS ON THE FIRST FLOOR OF THE TRAINING BUILDING

TO BE TYPE 2A / S, SW. U.N.O.

2. ALL PARTITIONS ON THE SECOND FLOOR OF THE TRAINING

BUILDING TO BE TYPE 2A / T @ 10’-0", SW. U.N.O.

3. ALL PARTITIONS IN THE OMS / AMSA BUILDING TO BE TYPE 2A / S,

SW. U.N.O.

4. INSTALL POLYVINYL CORNER GUARDS 6" A.F.F. TO 6" BELOW THE

CEILING WHERE INDICATED ON THE PLAN FOR ALL PUBLIC

SPACES.

5. SEE THE INTERIOR DRAWINGS FOR ALL FURNITURE AND

EQUIPMENT LAYOUTS.

6. DIMENSIONS ARE TO COLUMN LINES, FACE OF MASONRY, OR FACE

OF GYP.

7. SEE TYPICAL MOUNTING HEIGHTS ELEVATION ON 00-G-003 AND

00-A-500.

8. SEE FINISH SCHEDULE AND FINISH PLANS FOR ALL FINISH INFO.

4’ 8’0 2’

SCALE:1/4"=1’

GENERAL NOTES

GRAPHIC SCALE

KEY NOTES

File details come from the government source that posted it. Updated .