AF54B2-1.PDF
PDF 558 KB Posted
- Attached to
- PA 206 HORSHAM HVAC SYSTEMS REPAIRS
- Solicitation number
- W912BU24R0001
About this file
This document package includes architectural drawings and specifications for elevator modernization work at the Army Reserve Training Center in Horsham, Pennsylvania. The drawings show existing floor plans and sections of the elevator and shaft on the first and second floors, including details of the elevator cab, hoist beam, guide rails, pit, and fire rated assemblies. The related federal contract opportunity is solicitation number W912BU24R0001 from the Department of the Army Corps of Engineers Philadelphia District for HVAC system repairs at the PA 206 facility in Horsham. The requirement includes maintenance, repair, and replacement work for air handling units, fans, pumps, ductwork, controls and other HVAC components. The response due date is not provided.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W912BU24R0001 Amendment 0009_Cancellation.pdf | ||
| W912BU24R0001 Amendment 0005.pdf | ||
| AFC015-1.PDF | ||
| AF7200-1.PDF | ||
| AF7DA6-1.PDF | ||
| AF47CB-1.PDF | ||
| AF0F76-1.PDF | ||
| AF2040-1.PDF | ||
| AFRC55-1.PDF | ||
| 00-MP-1.PDF | ||
| 10-M-802.pdf | ||
| AF43EA-1.PDF | ||
| AF97A7-1.PDF | ||
| 00-M-801.pdf | ||
| AFD13B-1.PDF | ||
| AFF300-1.PDF | ||
| 00-M-808.pdf | ||
| AF1533-1.PDF | ||
| AF2872-1.PDF | ||
| 00-MH-2.PDF | ||
| AF7BD0-1.PDF | ||
| 00-M-201.pdf | ||
| AF9D55-1.PDF | ||
| 00-M-602.pdf | ||
| AF0EF7-1.PDF | ||
| AF4E85-1.PDF | ||
| AF1DF0-1.PDF | ||
| AFFC93-1.PDF | ||
| 10-MH-1.PDF | ||
| AF69FD-1.PDF | ||
| AFF200-1.PDF | ||
| 00-M-806.pdf | ||
| AFFC3F-1.PDF | ||
| AF377B-1.PDF | ||
| 00-MP-2.PDF | ||
| AF9D68-1.PDF | ||
| AFC2EA-1.PDF | ||
| AF1E68-1.PDF | ||
| AFA040-1.PDF | ||
| 10-M-800.pdf | ||
| AF8467-1.PDF | ||
| AFFB36-1.PDF | ||
| AF5A0C-1.PDF | ||
| 10-M-804.pdf | ||
| AF970C-1.PDF | ||
| AFRC55-3.PDF | ||
| 00-M-807.pdf | ||
| AF0467-1.PDF | ||
| AF2EB8-1.PDF | ||
| AF400F-1.PDF |
Show 40 more
Latest 50 of 108 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
00-A-811
A5 1/4" = 1’-0"
A1 1/2" = 1’-0"
ELEVATOR - FIRST FLOOR PLAN
B5 1/4" = 1’-0"
ELEVATOR - SECOND FLOOR PLAN
ELEVATOR - SECTION
A3
1/2" = 1’-0"
ELEVATOR - SECTION
T R
A
IN
IN
G C
E N
T E
R E
N L
A R
G E
D P
L A
N A
N D S
E C
T
IO
N E
L E
V A
T O
R
C5 1/4" = 1’-0"
ELEVATOR - PIT PLAN
2’ 4’0 1’
SCALE:1/2"=1’-0"
2’ 4’0 1’
SCALE:1/2"=1’-0"
4’ 8’0 2’
SCALE:1/4"=1’
PLAN
NORTH
4’ 8’0 2’
SCALE:1/4"=1’
PLAN
NORTH
4’ 8’0 2’
SCALE:1/4"=1’
PLAN
NORTH
AS-BUILT
S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5500-A-811.dgn
9/11/2012
9:27:45 AM
rifem
F O
R U
M S
T U
D
IO
I
N N
E R
B E
L T B
U S
IN
E S
S C
E N
T E
R D
R
S T L
O U
IS
M O
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
fi
US Army Corps of Engineers
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S I
D
L O
U
IS
V
IL
L E D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K Y
F S
B A
Z
C L
A Y
C O C
O N
S T
R U
C T
IO
N
.1
.1
-W
Q R -0
-R -0
P -1
1 3
C O
N C
E P
T D
E S
IG
N S
U B
M
IT
T A
L .1
.0
.1
.0
R
E V
IS
E D C
H A
R R
E T
T E C
O N
C E
P T S
U B
M
IT
T A
L
IN
T
E R
IM
S
U B
M
IT
T A
L .1
.1
.2
.1
A F
R C
-A -8
.d g n
/1
/2
F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L
A R
M Y R
E S
E R
V E T
R A
IN
IN
G C
E N
T E
R W
IL
L O
W G
R O
V E N
A V
A L A
IR
S
T A
T
IO
N W
Q R -0
-C -0
H O
R S
H A
M P
A
C
O R
R E
C T
E D F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L .0
.1
.1
.1
C
E R
T
IF
IE
D F
IN
A L S
U B
M
IT
T A
L
B R
IC
E Z
IC
K U
H R
D
/8
A3
A1
8’-10 1/4 " CLEAR 2’-9 3/8 "
1’-11 1/4 " 7’-7 3/8 " 2’-7 5/8 "
D
210J
CLOSET
A
ELEVATOR
ELEVATOR RM.
A
ELEVATOR
4A
S
4A
S
4A
S
4A
S
4A
S
1A
S
1A
S
2A
T
2A
T
210J
D
2’-9 3/8 "8’-10 1/4 "
2E
S
2E
S
2E
S
1’-1 5/8 "
3’-6"4’-2 5/8 "
4’-2 5/8 " 3’-6" 1’-1 5/8 "
SW
SW
SW
SW
SW
SW
SW
ELEVATOR
GUIDE RAILS
ACCESS LADDER
ELEVATOR PIT
FOUNDATION
WALL
LINE OF
ELEVATOR PIT
FOUNDATION
SUMP PIT
2’-0" D.
SW
SW
SW
2’-0"
3.22.7
/8
C L E
A R
/2
/8
C L E
A R
/2
A3
A1
8’-10 1/4 " CLEAR 2’-9 3/8 "
/8
C L E
A R
/2
100’-0"
1ST FLOOR
114’-0"
2ND FLOOR
94’-8"
ELEVATOR PIT
2ND FLOOR
114’-0"
1ST FLOOR
100’-0"
ELEVATOR PIT
94’-8"
00-A-812
C4
A4
3 D
2’-10" 6 1/2 "
128’-0"
RATED SHAFT CEILING
128’-0"
RATED SHAFT CEILING
HOIST BEAM
HOIST BEAM
2HR RATED SHAFT WALL ASSEMBLY
2HR RATED SHAFT WALL
ASSEMBLY
ACCESS LADDER
LIGHT FIXTURE
LIGHT SWITCH AND
GFIC OUTLET
ELEVATOR CAB
WATERPROOFING MEMBRANE
SEE SPEC
TUBE STEEL STRUCTURAL BACKUP
BEYOND
A2
00-A-812
FIRE RATED CEILING ASSEMBLY
REFER TO NER 258
FIRE RATED CEILING ASSEMBLY
REFER TO NER 258
File details come from the government source that posted it. Updated .