AFD13B-1.PDF

PDF 581 KB Posted

Attached to
PA 206 HORSHAM HVAC SYSTEMS REPAIRS
Solicitation number
W912BU24R0001
Issued by

About this file

This document contains an architectural floor plan and notes for the Army Reserve Training Center Willow Grove Naval Air Station in Horsham, Pennsylvania. Key details include specifications for partition types and locations throughout the facility, notes regarding installation of coat hooks, corner guards, blinds, and reference to other drawings for furniture and equipment layouts. Dimensions are shown from column lines, faces of masonry, or gypsum board. A material legend for hatched wall types is referenced.

The related federal contract opportunity is solicitation number W912BU24R0001 for HVAC system repairs at PA 206 Horsham. The opportunity was issued by the Department of the Army Corps of Engineers Engineering District Philadelphia. No further product, service, pricing or schedule details are provided.

View the file

Other files

File Type Posted
W912BU24R0001 Amendment 0009_Cancellation.pdf PDF
W912BU24R0001 Amendment 0005.pdf PDF
AFC015-1.PDF PDF
AF7200-1.PDF PDF
AF7DA6-1.PDF PDF
AF47CB-1.PDF PDF
AF0F76-1.PDF PDF
AF2040-1.PDF PDF
AFRC55-1.PDF PDF
00-MP-1.PDF PDF
10-M-802.pdf PDF
AF43EA-1.PDF PDF
AF97A7-1.PDF PDF
00-M-801.pdf PDF
AFF300-1.PDF PDF
00-M-808.pdf PDF
AF1533-1.PDF PDF
AF2872-1.PDF PDF
00-MH-2.PDF PDF
AF7BD0-1.PDF PDF
00-M-201.pdf PDF
AF9D55-1.PDF PDF
00-M-602.pdf PDF
AF0EF7-1.PDF PDF
AF4E85-1.PDF PDF
AF1DF0-1.PDF PDF
AFFC93-1.PDF PDF
10-MH-1.PDF PDF
AF69FD-1.PDF PDF
AFF200-1.PDF PDF
00-M-806.pdf PDF
AF54B2-1.PDF PDF
AFFC3F-1.PDF PDF
AF377B-1.PDF PDF
00-MP-2.PDF PDF
AF9D68-1.PDF PDF
AFC2EA-1.PDF PDF
AF1E68-1.PDF PDF
AFA040-1.PDF PDF
10-M-800.pdf PDF
AF8467-1.PDF PDF
AFFB36-1.PDF PDF
AF5A0C-1.PDF PDF
10-M-804.pdf PDF
AF970C-1.PDF PDF
AFRC55-3.PDF PDF
00-M-807.pdf PDF
AF0467-1.PDF PDF
AF2EB8-1.PDF PDF
AF400F-1.PDF PDF
Show 40 more

Latest 50 of 108 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

10-A-102

1/8" = 1’ 0" A4

FLOOR PLAN - WEST

AS-BUILT

O M

S A

M S

A F

L O

O R P

L A

N W

E S

T

S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5510-A-102.dgn

9/11/2012

9:32:09 AM

rifem

F O

R U

M S

T U

D

IO

I

N N

E R

B E

L T B

U S

IN

E S

S C

E N

T E

R D

R

S T L

O U

IS

M O

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

SHEET

IDENTIFICATION

D A

T E

A P

P R

SHEET OF

fi

US Army Corps of Engineers

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

L O

U

IS

V

IL

L E D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K Y

GENERAL NOTES

KEY PLAN

KEY NOTES

GRAPHIC SCALE

8’0 4’ 16’

SCALE:1/8"=1’

F S

B A

Z

C L

A Y

C O C

O N

S T

R U

C T

IO

N

.1

.1

-W

Q R -0

-R -0

P -1

1 3

C O

N C

E P

T D

E S

IG

N S

U B

M

IT

T A

L .1

.0

.1

.0

R

E V

IS

E D C

H A

R R

E T

T E C

O N

C E

P T S

U B

M

IT

T A

L

IN

T

E R

IM

S

U B

M

IT

T A

L .1

.1

.2

.1

A F

R C

-A -1

.d g n

/1

/2

F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L

A R

M Y R

E S

E R

V E T

R A

IN

IN

G C

E N

T E

R W

IL

L O

W G

R O

V E N

A V

A L A

IR

S

T A

T

IO

N W

Q R -0

-C -0

H O

R S

H A

M P

A

C

O R

R E

C T

E D F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L .0

.1

.1

.1

C

E R

T

IF

IE

D F

IN

A L S

U B

M

IT

T A

L

B R

IC

E Z

IC

K U

H R

M A

T C

H L

IN

E

A

-A -1

PLAN

NORTH

A .0

150A.02150A.03150A.04150A.05

150A.06

150A.07

150A.08 150A.09 150A.10 150A.11

A .1

02HI

LO

02HI

LO

02HI

LO

02HI

LO

1’-0"

3’-4"2’-0"16’-0"4’-0"16’-0"4’-0"16’-0"4’-0"16’-0"4’-4"2’-0"

TRENCH DRAIN - SLOPE FLOOR TO DRAIN

BOLLARD - SEE TYPICAL DETAILS ON SHEET 10-A-521

2 2

2 2

1 1

2 2

2 2

2 2

3’-4"2’-0"16’-0"4’-0"16’-0"

2’-0"2’-0"

16’-0" 2’-0"2’-0"

16’-0"4’-4"2’-0"

1 1.5 2 3

321.51

E

D

C.5

C

B

A

B.5

150A

WORK BAYS

1. ALL PARTITIONS ON THE FIRST FLOOR OF THE TRAINING BUILDING

TO BE TYPE 2A / S, SW. U.N.O.

2. ALL PARTITIONS ON THE SECOND FLOOR OF THE TRAINING

BUILDING TO BE TYPE 2A / T @ 10’-0", SW. U.N.O.

3. ALL PARTITIONS IN THE OMS / AMSA BUILDING TO BE TYPE 2A / S,

SW. U.N.O.

4. INSTALL A COAT HOOK ON THE WALL BEHIND THE DOOR IN ITS

OPENED POSITION IN THE SUPPLY OFFICE, FACILITY MANAGER,

FAMILY SUPPORT, REC / RET OFFICE, AND ALL PRIVATE OFFICES,

SEE THE TYPICAL MOUNTING HEIGHTS ELEVATION ON 00-G-003.

5. INSTALL POLYVINYL CORNER GUARDS 6" A.F.F. TO 6" BELOW THE

CEILING WHERE INDICATED ON THE PLAN FOR ALL PUBLIC

SPACES.

6. INSTALL STEEL CORNER GUARDS 6" A.F.F. TO 6" BELOW THE

CEILING WHERE INDICATED ON THE PLAN IN THE UNIT STORAGE

SPACE ONLY.

7. PROVIDE BLINDS AT ALL EXTERIOR WINDOWS.

8. SEE THE INTERIOR DRAWINGS FOR ALL FURNITURE AND

EQUIPMENT LAYOUTS.

9. DIMENSIONS ARE TO COLUMN LINES, FACE OF MASONRY, OR FACE

OF GYP.

10. REFER TO 00-G-003 FOR MATERIAL LEGEND OF HATCHED WALL TYPES.