AF9D55-1.PDF
PDF 1 MB Posted
- Attached to
- PA 206 HORSHAM HVAC SYSTEMS REPAIRS
- Solicitation number
- W912BU24R0001
About this file
This document contains architectural drawings and interior elevation plans for renovations to an Army Reserve Training Center and OMS/AMSA building. Key details include floor plans showing layouts for training rooms, locker rooms, offices, and other facilities; notations specifying partition types and materials to be used; and general notes outlining requirements for window blinds, furniture placement, dimensioning, and installation of corner guards. The related federal contract opportunity is a solicitation seeking bids for HVAC system repairs at the PA 206 Horsham facility, with the solicitation number provided and the contracting agency listed as the Department of the Army Corps of Engineers Engineering District Philadelphia.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W912BU24R0001 Amendment 0009_Cancellation.pdf | ||
| W912BU24R0001 Amendment 0005.pdf | ||
| AFC015-1.PDF | ||
| AF7200-1.PDF | ||
| AF7DA6-1.PDF | ||
| AF47CB-1.PDF | ||
| AF0F76-1.PDF | ||
| AF2040-1.PDF | ||
| AFRC55-1.PDF | ||
| 00-MP-1.PDF | ||
| 10-M-802.pdf | ||
| AF43EA-1.PDF | ||
| AF97A7-1.PDF | ||
| 00-M-801.pdf | ||
| AFD13B-1.PDF | ||
| AFF300-1.PDF | ||
| 00-M-808.pdf | ||
| AF1533-1.PDF | ||
| AF2872-1.PDF | ||
| 00-MH-2.PDF | ||
| AF7BD0-1.PDF | ||
| 00-M-201.pdf | ||
| 00-M-602.pdf | ||
| AF0EF7-1.PDF | ||
| AF4E85-1.PDF | ||
| AF1DF0-1.PDF | ||
| AFFC93-1.PDF | ||
| 10-MH-1.PDF | ||
| AF69FD-1.PDF | ||
| AFF200-1.PDF | ||
| 00-M-806.pdf | ||
| AF54B2-1.PDF | ||
| AFFC3F-1.PDF | ||
| AF377B-1.PDF | ||
| 00-MP-2.PDF | ||
| AF9D68-1.PDF | ||
| AFC2EA-1.PDF | ||
| AF1E68-1.PDF | ||
| AFA040-1.PDF | ||
| 10-M-800.pdf | ||
| AF8467-1.PDF | ||
| AFFB36-1.PDF | ||
| AF5A0C-1.PDF | ||
| 10-M-804.pdf | ||
| AF970C-1.PDF | ||
| AFRC55-3.PDF | ||
| 00-M-807.pdf | ||
| AF0467-1.PDF | ||
| AF2EB8-1.PDF | ||
| AF400F-1.PDF |
Show 40 more
Latest 50 of 108 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
10-A-4011/4" = 1’ 0" A4
ENLARGED FLOOR PLAN
1/4" = 1’ 0"
A2
INTERIOR ELEVATION
1/4" = 1’ 0" B2
INTERIOR ELEVATION
1/4" = 1’ 0" C2
INTERIOR ELEVATION
1/4" = 1’ 0" D2
INTERIOR ELEVATION
1/4" = 1’ 0" C1
INTERIOR ELEVATION
B1
INTERIOR ELEVATION
1/4" = 1’ 0"
4’ 8’0 2’
SCALE:1/4"=1’
4’ 8’0 2’
SCALE:1/4"=1’
4’ 8’0 2’
SCALE:1/4"=1’
4’ 8’0 2’
SCALE:1/4"=1’
4’ 8’0 2’
SCALE:1/4"=1’
4’ 8’0 2’
SCALE:1/4"=1’
A1 1’ 2’0 6"
SCALE:1-1/2"=1’
ENLARGED TILE PATTERN
1-1/2" = 1’ 0"
1/4" = 1’ 0" D4
INTERIOR ELEVATION
4’ 8’0 2’
SCALE:1/4"=1’
1/4" = 1’ 0" D5
INTERIOR ELEVATION
4’ 8’0 2’
SCALE:1/4"=1’
REVISED AS-BUILT
F
IE
L D C
O N
D
IT
IO
N
O M
S A
M S
A E
N L
A R
G E
D F
L O
O R P
L A
N A
N D I
N T
E R
IO
R E
L E
V A
T
IO
N S
7 7
S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5510-A-401.dgn
9/11/2012
9:34:10 AM
rifem
F O
R U
M S
T U
D
IO
I
N N
E R
B E
L T B
U S
IN
E S
S C
E N
T E
R D
R
S T L
O U
IS
M O
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
fi
US Army Corps of Engineers
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S I
D
L O
U
IS
V
IL
L E D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K Y
4’ 8’0 2’
SCALE:1/4"=1’
F S
B A
Z
C L
A Y
C O C
O N
S T
R U
C T
IO
N
.1
.1
-W
Q R -0
-R -0
P -1
1 3
C O
N C
E P
T D
E S
IG
N S
U B
M
IT
T A
L .1
.0
.1
.0
R
E V
IS
E D C
H A
R R
E T
T E C
O N
C E
P T S
U B
M
IT
T A
L
IN
T
E R
IM
S
U B
M
IT
T A
L .1
.1
.2
.1
A F
R C
-A -4
.d g n
/1
/2
F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L
A R
M Y R
E S
E R
V E T
R A
IN
IN
G C
E N
T E
R W
IL
L O
W G
R O
V E N
A V
A L A
IR
S
T A
T
IO
N W
Q R -0
-C -0
H O
R S
H A
M P
A
C
O R
R E
C T
E D F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L .0
.1
.1
.1
C
E R
T
IF
IE
D F
IN
A L S
U B
M
IT
T A
L
B R
IC
E Z
IC
K U
H R154A.1
153A.1
A .2
153B
MENS LOCKERS
153A
MENS
TLT / SHOWER
154A
WOMENS
TLT / SHOWER
6 5/8 " 19’-7"
A .2
3A
T
SW
10-A-401
B2
2’-4"3’-9 1/2 "5’-4 5/8 "3’-4 1/2 "
4’-5 5/8 "
1A
U
3A
T
SW
C
B E
E
1A
U
ALIGN
C
C.5
K
TYP.
10-A-401
A2
10-A-401
C1
D2
PLAN
NORTH
TYP.
TYP.
C L
C L
C L
C L
C L
2’-0" 4’-5 3/8 "
C L
9’-2 3/8 " 4’-6"
TYP.
C L
C L
2A
U
2A
U
SW
2A
U
SW
2A
U
SW
2A
U
SW
2A
U
SW
10-A-401
C2
B1
/4
L
O C
K E
R S
4 LOCKERS @ 4’-0"
1’-3 1/4 "
4’-2 3/8 "11’-1 5/8 "
C
D
B
J
A
K
LL
H
F
H
F
E
K
J
A
C M
N
L
C
F
E
H
A
J
K
/4
/4
/4
11 LOCKERS @ 11’-0"
/8
/8
/8
/4
/8 C
L E
A R
/8
A4
10-A-541
A4
10-A-541
N
SW
2K
S
SW
2K
S
SW
2A
T
2A
T
SW
JANITOR
2A
T
SW
2’-0"
2A
T
SW
A1
2’-6" 1’-6"
3’-0"
B4
10-A-541
10-A-541
B2 B4
10-A-541
3’-0"3’-0"
2’-3"3’-0"
5’-0" CLEAR
3’-4 7/8 "
11 1/2 "
5’-0"2’-10 3/4 "5’-1 3/4 "
C L E
A R
/8
C L E
A R
5’-1 3/4 " 5’-0" CLEAR 5’-6 1/8 "
2’-2 7/8 "3’-3 1/4 "10’-11 1/2 "6’-7 1/4 "
/8
/8
/4
F
H
C L
M
N J A
J
A
B
K
C
DN
M
L
L L
F
H
LOCKER ROOM BENCHES
FIBERGLASS SHOWER SURROUND TO BE APPLIED TO ALL GYP. BOARD
SURFACES IN THE SHOWERS
SHOWER CURTAIN AND ROD TO BE MOUNTED AT 7’-0" A.F.F.
ELECTRIC DRINKING FOUNTAIN
1 TIER METAL LOCKER 1’-0"W x 1’-6"D x 7’-0"H
FRAMELESS MIRROR @ 4’-0"H
WOOD DOOR WITH PAINTED HM FRAME, SEE FINISH SCHEDULE FOR MORE
INFORMATION
FULL-HEIGHT TILE, SEE FINISH SCHEDULE FOR MORE INFORMATION
SOLID SURFACE COUNTER, BACK AND SIDE INTEGRAL COVE SPLASHES WITH
PLASTIC LAMINATE CABINETS
STAINLESS STEEL REFRIGERATOR
8’-0" x 4’-0" MARKER BOARD WITH 1/4" ALUMINUM TRIM AND 2" MAP RAIL ON TOP.
DOUBLE BOWL STAINLESS STEEL SINK
PAINTED GYP. BOARD PARTITION, SEE FINISH SCHEDULE FOR MORE
INFORMATION
SCHEDULED RESILIENT BASE, SEE FINISH SCHEDULE FOR MORE INFORMATION
MICROWAVE PROVIDED BY OTHERS
1. ALL PARTITIONS ON THE FIRST FLOOR OF THE TRAINING BUILDING
TO BE TYPE 2A / S, SW. U.N.O.
2. ALL PARTITIONS ON THE SECOND FLOOR OF THE TRAINING
BUILDING TO BE TYPE 2A / T @ 10’-0", SW. U.N.O.
3. ALL PARTITIONS IN THE OMS / AMSA BUILDING TO BE TYPE 2A / S,
SW. U.N.O.
4. INSTALL A COAT HOOK ON THE WALL BEHIND THE DOOR IN ITS
OPENED POSITION IN THE SUPPLY OFFICE, FACILITY MANAGER,
FAMILY SUPPORT, REC / RET OFFICE, AND ALL PRIVATE OFFICES,
SEE THE TYPICAL MOUNTING HEIGHTS ELEVATION ON 00-G-003.
5. INSTALL POLYVINYL CORNER GUARDS 6" A.F.F. TO 6" BELOW THE
CEILING WHERE INDICATED ON THE PLAN FOR ALL PUBLIC
SPACES.
6. INSTALL STEEL CORNER GUARDS 6" A.F.F. TO 6" BELOW THE
CEILING WHERE INDICATED ON THE PLAN IN THE UNIT STORAGE
SPACE ONLY.
7. PROVIDE BLINDS AT ALL EXTERIOR WINDOWS.
8. SEE THE INTERIOR DRAWINGS FOR ALL FURNITURE AND
EQUIPMENT LAYOUTS.
9. DIMENSIONS ARE TO COLUMN LINES, FACE OF MASONRY, OR FACE
OF GYP.
10. REFER TO 00-G-003 FOR MATERIAL LEGEND OF HATCHED WALL TYPES.
4’ 8’0 2’
SCALE:1/4"=1’
GENERAL NOTES
GRAPHIC SCALE
KEY NOTES
TOILET ACCESSORY LEGEND
CT-5
CT-7
CT-6
CT-4
CT-3
CT-4 CT-4
CT-3CT-3
CT-3
PATTERN REPEAT
TYP.
TYP.
TYP.
File details come from the government source that posted it. Updated .