AF7200-1.PDF

PDF 729 KB Posted

Attached to
PA 206 HORSHAM HVAC SYSTEMS REPAIRS
Solicitation number
W912BU24R0001
Issued by

About this file

This document contains architectural drawings and details for door, window, and storefront installations, as well as information on a related federal contract opportunity for HVAC systems repairs. The solicitation is number W912BU24R0001 from the Department of the Army Corps of Engineers Engineering District Philadelphia for repairs to the HVAC systems at PA 206 Horsham. The opportunity is for repair work only, as indicated by the type being listed as a solicitation. No further details are provided on response dates, award dates, pricing terms, set asides, incumbents or other salient information. The architectural drawings show details for metal doors and frames, aluminum doors and frames, brick veneer construction, thresholds, windows, and related elements.

View the file

Other files

File Type Posted
W912BU24R0001 Amendment 0009_Cancellation.pdf PDF
W912BU24R0001 Amendment 0005.pdf PDF
AFC015-1.PDF PDF
AF7DA6-1.PDF PDF
AF47CB-1.PDF PDF
AF0F76-1.PDF PDF
AF2040-1.PDF PDF
AFRC55-1.PDF PDF
00-MP-1.PDF PDF
10-M-802.pdf PDF
AF43EA-1.PDF PDF
AF97A7-1.PDF PDF
00-M-801.pdf PDF
AFD13B-1.PDF PDF
AFF300-1.PDF PDF
00-M-808.pdf PDF
AF1533-1.PDF PDF
AF2872-1.PDF PDF
00-MH-2.PDF PDF
AF7BD0-1.PDF PDF
00-M-201.pdf PDF
AF9D55-1.PDF PDF
00-M-602.pdf PDF
AF0EF7-1.PDF PDF
AF4E85-1.PDF PDF
AF1DF0-1.PDF PDF
AFFC93-1.PDF PDF
10-MH-1.PDF PDF
AF69FD-1.PDF PDF
AFF200-1.PDF PDF
00-M-806.pdf PDF
AF54B2-1.PDF PDF
AFFC3F-1.PDF PDF
AF377B-1.PDF PDF
00-MP-2.PDF PDF
AF9D68-1.PDF PDF
AFC2EA-1.PDF PDF
AF1E68-1.PDF PDF
AFA040-1.PDF PDF
10-M-800.pdf PDF
AF8467-1.PDF PDF
AFFB36-1.PDF PDF
AF5A0C-1.PDF PDF
10-M-804.pdf PDF
AF970C-1.PDF PDF
AFRC55-3.PDF PDF
00-M-807.pdf PDF
AF0467-1.PDF PDF
AF2EB8-1.PDF PDF
AF400F-1.PDF PDF
Show 40 more

Latest 50 of 108 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

00-A-702

B4 3" = 1’-0"

H.M. DOOR HEAD DETAIL

H.M. DOOR JAMB DETAIL

3" = 1’-0"

C4

3" = 1’-0" B3

C3 3" = 1’-0"

ALUM. FRAME DOOR JAMB DETAIL

ALUM. FRAME DOOR HEAD DETAIL

ALUM. FRAME DOOR SILL DETAIL

A3

3" = 1’-0" A4

3" = 1’-0"

ALUM. FRAME WINDOW SILL DETAIL

SCALE: 3"=1’

3" 6" 9" 12"

SCALE: 3"=1’

3" 6" 9" 12"

SCALE: 3"=1’

3" 6" 9" 12"

SCALE: 3"=1’

3" 6" 9" 12"

SCALE: 3"=1’

3" 6" 9" 12" 0

SCALE: 3"=1’

3" 6" 9" 12"

AS-BUILT

T R

A

IN

IN

G C

E N

T E

R D

O O

R

W

IN

D O

W A

N D S

T O

R E

F R

O N

T D

E T

A

IL

S

S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5500-A-702.dgn

9/11/2012

9:26:50 AM

rifem

F O

R U

M S

T U

D

IO

I

N N

E R

B E

L T B

U S

IN

E S

S C

E N

T E

R D

R

S T L

O U

IS

M O

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

SHEET

IDENTIFICATION

D A

T E

A P

P R

SHEET OF

fi

US Army Corps of Engineers

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

L O

U

IS

V

IL

L E D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K Y

F S

B A

Z

C L

A Y

C O C

O N

S T

R U

C T

IO

N

.1

.1

-W

Q R -0

-R -0

P -1

1 3

C O

N C

E P

T D

E S

IG

N S

U B

M

IT

T A

L .1

.0

.1

.0

R

E V

IS

E D C

H A

R R

E T

T E C

O N

C E

P T S

U B

M

IT

T A

L

IN

T

E R

IM

S

U B

M

IT

T A

L .1

.1

.2

.1

A F

R C

-A -7

.d g n

/1

/2

F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L

A R

M Y R

E S

E R

V E T

R A

IN

IN

G C

E N

T E

R W

IL

L O

W G

R O

V E N

A V

A L A

IR

S

T A

T

IO

N W

Q R -0

-C -0

H O

R S

H A

M P

A

C

O R

R E

C T

E D F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L .0

.1

.1

.1

C

E R

T

IF

IE

D F

IN

A L S

U B

M

IT

T A

L

B R

IC

E Z

IC

K U

H R

SCHEDULED H.M.

DOOR AND FRAME

CMU BLOCK WITH

FINISHED CORNER

CMU BOND BEAM

A.M.B.S.

BRICK VENEER

GALV. STL. ANGLE

LINTEL - PT.

VENTED WEEPS @

24" O.C.

SELF ADHERING

MEMBRANE

FLASHING.

EXTEND 1" PAST FACE

OF BRICK. TRIM

FLUSH AT

COMPLETION.

ALUM. DOOR /

FRAME AS

SCHEDULED

MTL. STUD BOX

BEAM - FILL W/

INSUL.

MORTAR NET

TAPEABLE J-MOLD &

SEALANT

A.M.B.S.

BRICK VENEER

ALUM. DOOR /

FRAME AS

SCHEDULED

DOUBLE MTL. STUD -

FILL W/ INSUL.

CONT. SEALANT W/

BACKER ROD INT. &

EXT.

5/8" GYP. BD. ON 6"

MTL. STUD

BATT INSUL.

TAPEABLE J-MOLD &

SEALANT

2" RIGID INSUL.

ADA COMPLIANT

THRESHOLD IN FULL

MASTIC BED

ALUM. DOOR AS

SCHEDULED

FACE OF EXTERIOR

WALL BEYOND

GLAZING AS

SCHEDULED

BRICK VENEER

RETURN

2" RIGID INSUL.

CONT. SEALANT W/

BACKER ROD INT. &

EXT.

EXTERIOR SHEATHING

5/8" GYP. BD. ON 6"

MTL. STUD

BATT INSUL.

A.M.B.S.

BRICK VENEER

CONT. SEALANT W/

BACKER ROD INT. &

EXT.

2" RIGID INSUL.

BRICK VENEER

RETURN

A.M.B.S.

BRICK VENEER

GALV. STL. ANGLE

LINTEL - PT.

VENTED WEEPS @

24" O.C.

SELF ADHERING

MEMBRANE

FLASHING.

EXTEND 1" PAST FACE

OF BRICK. TRIM

FLUSH AT

COMPLETION.

MORTAR NET

NOTE: DO NOT

ANCHOR INTO

MASONRY LINTEL

2" RIGID INSUL.

CONT. SEALANT W/

BACKER ROD INT. &

EXT.

EXTERIOR SHEATHING

SCHEDULED H.M.

DOOR AND FRAME

MASONRY JAMB

ANCHORS

(3) PER SIDE

NOTE: DO NOT

ANCHOR INTO

MASONRY LINTEL

MASONRY ANCHOR

MASONRY ANCHOR

SILL PAN SET IN

MASTIC

SCHEDULED ALUM.

FRAME WINDOW

FACE OF EXTERIOR

WALL BEYOND

RIGID INSULATION

CONC. WALK

LEAN CONC. FILL

FROST BLOCK

SEALANT AND 1/2"

EXPANSION MAT

EDGE OF SLAB

BEYOND

RIGID INSULATION

CONC. WALK

LEAN CONC. FILL

FROST BLOCK

SEALANT AND 1/2"

EXPANSION MAT

EDGE OF SLAB

BEYOND

6 1/2 "

6 1/2 "

6 1/2 "

2 1/2 " 2 1/2 "

GROUT AND

REINFORCE

CORE

File details come from the government source that posted it. Updated .