This document contains a reflected ceiling plan and notes for the Army Reserve Training Center at Willow Grove Naval Air Station in Horsham, Pennsylvania. Key details include specifications for ceiling heights of 8'-8" throughout the first and second floors of the training building as well as the OMS/AMSA building. Lighting fixtures such as can lights, suspended lights, and lay in lights are shown on the plan. Sprinkler heads and projection screens are also noted. Acoustical ceiling tiles and gypsum board ceilings are specified. The related federal contract opportunity is for HVAC systems repairs at the PA 206 Horsham facility, solicited by the Department of the Army Corps of Engineers Engineering District Philadelphia under solicitation number W912BU24R0001.

View the file

Other files

File Type Posted
W912BU24R0001 Amendment 0009_Cancellation.pdf PDF
W912BU24R0001 Amendment 0005.pdf PDF
AFC015-1.PDF PDF
AF7200-1.PDF PDF
AF7DA6-1.PDF PDF
AF47CB-1.PDF PDF
AF0F76-1.PDF PDF
AF2040-1.PDF PDF
AFRC55-1.PDF PDF
00-MP-1.PDF PDF
10-M-802.pdf PDF
AF43EA-1.PDF PDF
AF97A7-1.PDF PDF
00-M-801.pdf PDF
AFD13B-1.PDF PDF
AFF300-1.PDF PDF
00-M-808.pdf PDF
AF1533-1.PDF PDF
AF2872-1.PDF PDF
00-MH-2.PDF PDF
AF7BD0-1.PDF PDF
00-M-201.pdf PDF
AF9D55-1.PDF PDF
00-M-602.pdf PDF
AF0EF7-1.PDF PDF
AF4E85-1.PDF PDF
AF1DF0-1.PDF PDF
AFFC93-1.PDF PDF
10-MH-1.PDF PDF
AF69FD-1.PDF PDF
AFF200-1.PDF PDF
00-M-806.pdf PDF
AF54B2-1.PDF PDF
AFFC3F-1.PDF PDF
00-MP-2.PDF PDF
AF9D68-1.PDF PDF
AFC2EA-1.PDF PDF
AF1E68-1.PDF PDF
AFA040-1.PDF PDF
10-M-800.pdf PDF
AF8467-1.PDF PDF
AFFB36-1.PDF PDF
AF5A0C-1.PDF PDF
10-M-804.pdf PDF
AF970C-1.PDF PDF
AFRC55-3.PDF PDF
00-M-807.pdf PDF
AF0467-1.PDF PDF
AF2EB8-1.PDF PDF
AF400F-1.PDF PDF
Show 40 more

Latest 50 of 108 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

10-A-113

1/8" = 1’ 0" A4

REFLECTED CEILING PLAN - EAST

O M

S A

M S

A R

E F

L E

C T

E D C

E

IL

IN

G P

L A

N E

A S

T

AS-BUILT

S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5510-A-113.dgn

5/30/2013

4:41:59 PM

rifem

F O

R U

M S

T U

D

IO

I

N N

E R

B E

L T B

U S

IN

E S

S C

E N

T E

R D

R

S T L

O U

IS

M O

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

SHEET

IDENTIFICATION

D A

T E

A P

P R

SHEET OF

fi

US Army Corps of Engineers

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

L O

U

IS

V

IL

L E D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K Y

GENERAL NOTES

KEY PLAN

KEY NOTES

GRAPHIC SCALE

8’0 4’ 16’

SCALE:1/8"=1’

F S

B A

Z

C L

A Y

C O C

O N

S T

R U

C T

IO

N

.1

.1

-W

Q R -0

-R -0

P -1

1 3

C O

N C

E P

T D

E S

IG

N S

U B

M

IT

T A

L .1

.0

.1

.0

R

E V

IS

E D C

H A

R R

E T

T E C

O N

C E

P T S

U B

M

IT

T A

L

IN

T

E R

IM

S

U B

M

IT

T A

L .1

.1

.2

.1

A F

R C

-A -1

.d g n

/3

/2

F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L

A R

M Y R

E S

E R

V E T

R A

IN

IN

G C

E N

T E

R W

IL

L O

W G

R O

V E N

A V

A L A

IR

S

T A

T

IO

N W

Q R -0

-C -0

H O

R S

H A

M P

A

C

O R

R E

C T

E D F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L .0

.1

.1

.1

C

E R

T

IF

IE

D F

IN

A L S

U B

M

IT

T A

L

B R

IC

E Z

IC

K U

H R

AMSA

CNTL WASTE STOR

155B

AMS TOOL ROOM

155A

AMS PARTS ROOM

140D

VESTIBULE

AMSA FLAM STOR

LIBRARY

MECHANICAL

ELECTRICAL

OMS

CNTL WASTE STOR

143B

F/T OFFICE

143C

F/T OFFICE

143A

OMS SHOP OFFICE

AMSA CLASS

BREAK ROOM

AMSA BATTERY ROOM

AMSA SHOP OFFICE

ELEC COMMO

TR.

140C

VESTIBULE

150C

ALCOVE

150B

EQUIP ALCOVE

145B

OMS TOOL & PARTS

145A

OMS STORAGE

153B

MENS LOCKERS

JANITOR

153A

MENS

TLT / SHOWER

154B

WOMENS LOCKERS

154A

WOMENS

TLT / SHOWER

140B

CORRIDOR

140A

CORRIDOR

OMS FLAM STOR

O.T.S.

O.T.S.

O.T.S.

O.T.S.

O.T.S.

O.T.S.

O.T.S.

O.T.S.

O.T.S.

O.T.S.

O.T.S.

8’-8"

O.T.S.

O.T.S.

8’-0"

8’-0"

8’-8"

8’-0"

8’-0"

M A

T C

H L

IN

E

A

-A -1

8’-0"

8’-0"

8’-8"

8’-8"

PLAN

NORTH

OVERHEAD POWERED PROJECTION SCREEN

ROOF RIDGE LINE FROM ABOVE

OVERHEAD DOOR TRACK

CEILING CONTROL JOINT, SEE 10-A-501 FOR MORE INFORMATION

3 4 5

A

B

B.5

C

C.5

D

E

TC

S

S

S

S

S

S

S

S

FACP F

F

F

P

P

P

P

P

P

P

P P T N

A C

P

P

CA

C A

CA

C A

C

A

CA

CA

C A

C

A

CA

C

A

C

A

C

A

S

S

S

S

S

C A

S

4WZAM

4WZAM

FF

C

A

F

CA

S

F

P

S

S

S

FF

REFLECTED CEILING LEGEND

8’-8"

R

CEILING TAG

PROJECTION SCREEN

CAN LIGHT

SUSPENDED LIGHT

FIXTURE

SURFACE MOUNTED

LIGHT FIXTURE

UPRIGHT

SPRINKLER

HEAD

SPRINKLER

HEAD

LAY IN

LIGHT

FIXTURE

RETURN/

EXHAUST

SUPPLY

PROJECTOR

ACOUSTICAL

CEILING TILE

GYP. BOARD

CEILING

SEE FIRE PROTECTION, MECHANICAL, PLUMBING AND ELECTRICAL

DRAWINGS FOR FURTHER INFORMATION

1. ALL CEILINGS ON THE FIRST FLOOR OF THE TRAINING BUILDING TO

BE 8’-8" A.F.F., U.N.O.

2. ALL CEILINGS ON THE SECOND FLOOR OF THE TRAINING BUILDING

TO BE 8’-8" A.F.F., U.N.O.

3. ALL CEILINGS IN THE OMS / AMSA BUILDING TO BE 8’-8" A.F.F.,

U.N.O.

4. REFER TO THE ELECTRICAL AND MECHANICAL DRAWINGS FOR THE

LIGHTING AND DIFFUSER LAYOUT.

5. ALL BULKHEADS ARE TO BE TYPE 2A / T, SEE REFLECTED CEILING

PLANS FOR HEIGHTS.

6. PROJECTION SCREENS AND PROJECTORS ARE SHOWN FOR

LOCATION SUGGESTION ONLY, SEE ELECTRICAL DRAWINGS FOR

FINAL LOCATIONS.

7. ALL CEILINGS NOTED AS O.T.S. (OPEN TO STRUCTURE) SHALL BE PAINTED