AF970C-1.PDF

PDF 841 KB Posted

Attached to
PA 206 HORSHAM HVAC SYSTEMS REPAIRS
Solicitation number
W912BU24R0001
Issued by

About this file

The document contains architectural floor plans and notes for an Army Reserve Training Center located at Naval Air Station Willow Grove in Horsham, Pennsylvania. Key details include floor plans for the overall site showing dimensions and spaces labeled for uses such as classrooms, offices, mechanical and electrical rooms. General notes specify that interior partitions will be fire-rated gypsum board and indicate where vinyl corner guards and steel corner guards will be installed, as well as providing details on window blinds, furniture layouts, and dimensioning and material callouts. The related federal contract opportunity is solicitation number W912BU24R0001 from the Department of the Army Corps of Engineers Engineering District Philadelphia for HVAC system repairs at the PA 206 Horsham facility.

View the file

Other files

File Type Posted
W912BU24R0001 Amendment 0009_Cancellation.pdf PDF
W912BU24R0001 Amendment 0005.pdf PDF
AFC015-1.PDF PDF
AF7200-1.PDF PDF
AF7DA6-1.PDF PDF
AF47CB-1.PDF PDF
AF0F76-1.PDF PDF
AF2040-1.PDF PDF
AFRC55-1.PDF PDF
00-MP-1.PDF PDF
10-M-802.pdf PDF
AF43EA-1.PDF PDF
AF97A7-1.PDF PDF
00-M-801.pdf PDF
AFD13B-1.PDF PDF
AFF300-1.PDF PDF
00-M-808.pdf PDF
AF1533-1.PDF PDF
AF2872-1.PDF PDF
00-MH-2.PDF PDF
AF7BD0-1.PDF PDF
00-M-201.pdf PDF
AF9D55-1.PDF PDF
00-M-602.pdf PDF
AF0EF7-1.PDF PDF
AF4E85-1.PDF PDF
AF1DF0-1.PDF PDF
AFFC93-1.PDF PDF
10-MH-1.PDF PDF
AF69FD-1.PDF PDF
AFF200-1.PDF PDF
00-M-806.pdf PDF
AF54B2-1.PDF PDF
AFFC3F-1.PDF PDF
AF377B-1.PDF PDF
00-MP-2.PDF PDF
AF9D68-1.PDF PDF
AFC2EA-1.PDF PDF
AF1E68-1.PDF PDF
AFA040-1.PDF PDF
10-M-800.pdf PDF
AF8467-1.PDF PDF
AFFB36-1.PDF PDF
AF5A0C-1.PDF PDF
10-M-804.pdf PDF
AFRC55-3.PDF PDF
00-M-807.pdf PDF
AF0467-1.PDF PDF
AF2EB8-1.PDF PDF
AF400F-1.PDF PDF
Show 40 more

Latest 50 of 108 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

10-A-101

1/16" = 1’ 0" A4

OVERALL FLOOR PLAN

O M

S A

M S

A O

V E

R A

L L F

L O

O R P

L A

N

AS-BUILT

S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5510-A-101.dgn

9/11/2012

9:32:00 AM

rifem

F O

R U

M S

T U

D

IO

I

N N

E R

B E

L T B

U S

IN

E S

S C

E N

T E

R D

R

S T L

O U

IS

M O

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

SHEET

IDENTIFICATION

D A

T E

A P

P R

SHEET OF

fi

US Army Corps of Engineers

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

L O

U

IS

V

IL

L E D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K Y

GENERAL NOTES

KEY PLAN

KEY NOTES

GRAPHIC SCALE

32’8’

SCALE:1/16"=1’

0 16’

F S

B A

Z

C L

A Y

C O C

O N

S T

R U

C T

IO

N

.1

.1

-W

Q R -0

-R -0

P -1

1 3

C O

N C

E P

T D

E S

IG

N S

U B

M

IT

T A

L .1

.0

.1

.0

R

E V

IS

E D C

H A

R R

E T

T E C

O N

C E

P T S

U B

M

IT

T A

L

IN

T

E R

IM

S

U B

M

IT

T A

L .1

.1

.2

.1

A F

R C

-A -1

.d g n

/1

/2

F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L

A R

M Y R

E S

E R

V E T

R A

IN

IN

G C

E N

T E

R W

IL

L O

W G

R O

V E N

A V

A L A

IR

S

T A

T

IO

N W

Q R -0

-C -0

H O

R S

H A

M P

A

C

O R

R E

C T

E D F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L .0

.1

.1

.1

C

E R

T

IF

IE

D F

IN

A L S

U B

M

IT

T A

L

B R

IC

E Z

IC

K U

H R

10-A-301

A5

A5

10-A-201

A4

10-A-201

C4

10-A-202

A4

10-A-202

C4

B3

B3

B5

B5 149

AMSA BATTERY ROOM

OMS FLAM STOR

AMSA SHOP OFFICE

150C

ALCOVE

150B

EQUIP ALCOVE

150A

WORK BAYS

143A

OMS SHOP OFFICE

143C

F/T OFFICE

143B

F/T OFFICE

AMSA CLASS

BREAK ROOM

ARNET/IT CLOSET

ELEC COMMO

145A

OMS STORAGE

153B

MENS LOCKERS

140C

VESTIBULE

153A

MENS

TLT / SHOWER

154A

WOMENS

TLT / SHOWER

154B

WOMENS LOCKERS

155A

AMS PARTS ROOM

155B

AMS TOOL ROOM

145B

OMS TOOL & PARTS

AMSA

CNTL WASTE STOR

AMSA FLAM STOR

LIBRARY

MECHANICAL

ELECTRICAL

OMS

CNTL WASTE STOR

140D

VESTIBULE

169’-4"

22’-4" 20’-4" 45’-8" 35’-10" 45’-2"

M A

T C

H L

IN

E

A

-A -1

M A

T C

H L

IN

E

A

-A -1

PLAN

NORTH

1 FROST SLAB W/ LEAN CONCRETE FILL

2 CONC. APRON RE: CIVIL

3 ROCK MULCH RE: CIVIL

1 11

11 3

5’-0"

1 1.5 2 3 4 5

E

D

C.5

C

B

A

B.5

1. ALL PARTITIONS ON THE FIRST FLOOR OF THE TRAINING BUILDING

TO BE TYPE 2A / S, SW. U.N.O.

2. ALL PARTITIONS ON THE SECOND FLOOR OF THE TRAINING

BUILDING TO BE TYPE 2A / T @ 10’-0", SW. U.N.O.

3. ALL PARTITIONS IN THE OMS / AMSA BUILDING TO BE TYPE 2A / S,

SW. U.N.O.

4. INSTALL A COAT HOOK ON THE WALL BEHIND THE DOOR IN ITS

OPENED POSITION IN THE SUPPLY OFFICE, FACILITY MANAGER,

FAMILY SUPPORT, REC / RET OFFICE, AND ALL PRIVATE OFFICES,

SEE THE TYPICAL MOUNTING HEIGHTS ELEVATION ON 00-G-003.

5. INSTALL POLYVINYL CORNER GUARDS 6" A.F.F. TO 6" BELOW THE

CEILING WHERE INDICATED ON THE PLAN FOR ALL PUBLIC

SPACES.

6. INSTALL STEEL CORNER GUARDS 6" A.F.F. TO 6" BELOW THE

CEILING WHERE INDICATED ON THE PLAN IN THE UNIT STORAGE

SPACE ONLY.

7. PROVIDE BLINDS AT ALL EXTERIOR WINDOWS.

8. SEE THE INTERIOR DRAWINGS FOR ALL FURNITURE AND

EQUIPMENT LAYOUTS.

9. DIMENSIONS ARE TO COLUMN LINES, FACE OF MASONRY, OR FACE

OF GYP.

10. REFER TO 00-G-003 FOR MATERIAL LEGEND OF HATCHED WALL TYPES.

File details come from the government source that posted it. Updated .