AFC015-1.PDF
PDF 536 KB Posted
- Attached to
- PA 206 HORSHAM HVAC SYSTEMS REPAIRS
- Solicitation number
- W912BU24R0001
About this file
This document includes as-built exterior elevation drawings and control joint location plans for the Army Reserve Training Center located at Willow Grove Naval Air Station in Horsham, Pennsylvania. The drawings show the north and east elevations of the building and identify the locations of masonry control joints on the exterior walls. Notes on the drawings specify details such as aligning control joints with openings, providing sealant transitions to match adjacent materials, and the waterproofing condition at control joints and loose lintels.
The related federal contract opportunity is solicitation number W912BU24R0001 from the Department of the Army Corps of Engineers Engineering District Philadelphia to perform HVAC systems repairs at the PA 206 facility in Horsham. The solicitation seeks a contractor to repair heating, ventilation, and air conditioning systems at the location.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W912BU24R0001 Amendment 0009_Cancellation.pdf | ||
| W912BU24R0001 Amendment 0005.pdf | ||
| AF7200-1.PDF | ||
| AF7DA6-1.PDF | ||
| AF47CB-1.PDF | ||
| AF0F76-1.PDF | ||
| AF2040-1.PDF | ||
| AFRC55-1.PDF | ||
| 00-MP-1.PDF | ||
| 10-M-802.pdf | ||
| AF43EA-1.PDF | ||
| AF97A7-1.PDF | ||
| 00-M-801.pdf | ||
| AFD13B-1.PDF | ||
| AFF300-1.PDF | ||
| 00-M-808.pdf | ||
| AF1533-1.PDF | ||
| AF2872-1.PDF | ||
| 00-MH-2.PDF | ||
| AF7BD0-1.PDF | ||
| 00-M-201.pdf | ||
| AF9D55-1.PDF | ||
| 00-M-602.pdf | ||
| AF0EF7-1.PDF | ||
| AF4E85-1.PDF | ||
| AF1DF0-1.PDF | ||
| AFFC93-1.PDF | ||
| 10-MH-1.PDF | ||
| AF69FD-1.PDF | ||
| AFF200-1.PDF | ||
| 00-M-806.pdf | ||
| AF54B2-1.PDF | ||
| AFFC3F-1.PDF | ||
| AF377B-1.PDF | ||
| 00-MP-2.PDF | ||
| AF9D68-1.PDF | ||
| AFC2EA-1.PDF | ||
| AF1E68-1.PDF | ||
| AFA040-1.PDF | ||
| 10-M-800.pdf | ||
| AF8467-1.PDF | ||
| AFFB36-1.PDF | ||
| AF5A0C-1.PDF | ||
| 10-M-804.pdf | ||
| AF970C-1.PDF | ||
| AFRC55-3.PDF | ||
| 00-M-807.pdf | ||
| AF0467-1.PDF | ||
| AF2EB8-1.PDF | ||
| AF400F-1.PDF |
Show 40 more
Latest 50 of 108 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
10-A-2041/8" = 1’ 0" A4
NORTH ELEVATION
1/8" = 1’ 0" C4
EAST ELEVATION
AS-BUILT
O M
S A
M S
A E
X T
E R
IO
R E
L E
V A
T
IO
N S
N
O R
T H A
N D E
A S
T M
A S
O N
R Y C
O N
T R
O L J
O
IN
T L
O C
A T
IO
N S
S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5510-A-204.dgn
9/11/2012
9:33:34 AM
rifem
F O
R U
M S
T U
D
IO
I
N N
E R
B E
L T B
U S
IN
E S
S C
E N
T E
R D
R
S T L
O U
IS
M O
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
fi
US Army Corps of Engineers
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S I
D
L O
U
IS
V
IL
L E D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K Y
F S
B A
Z
C L
A Y
C O C
O N
S T
R U
C T
IO
N
.1
.1
-W
Q R -0
-R -0
P -1
1 3
C O
N C
E P
T D
E S
IG
N S
U B
M
IT
T A
L .1
.0
.1
.0
R
E V
IS
E D C
H A
R R
E T
T E C
O N
C E
P T S
U B
M
IT
T A
L
IN
T
E R
IM
S
U B
M
IT
T A
L .1
.1
.2
.1
A F
R C
-A -2
.d g n
/1
/2
F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L
A R
M Y R
E S
E R
V E T
R A
IN
IN
G C
E N
T E
R W
IL
L O
W G
R O
V E N
A V
A L A
IR
S
T A
T
IO
N W
Q R -0
-C -0
H O
R S
H A
M P
A
C
O R
R E
C T
E D F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L .0
.1
.1
.1
C
E R
T
IF
IE
D F
IN
A L S
U B
M
IT
T A
L
B R
IC
E Z
IC
K U
H R
5 4 3 2 1.5 1
4’-4"17’-4"19’-4"14’-0"10’-0"17’-4"16’-8"8’-4"
6’-4"16’-0"4’-0"16’-0"4’-0"16’-0"4’-0"16’-0"6’-4"12’-0"10’-0"18’-8"17’-4"17’-4"9’-0"
MASONRY CONTROL JOINT LOCATION SEE DETAIL D4 ON SHEET 10-A-203
CONTROL JOINT LOCATIONS ALONG GRID LINE "D"CONTROL JOINT LOCATIONS ALONG GRID LINE "E"
1. ALIGN CONTROL JOINTS WITH WINDOW AND DOOR OPENINGS AS SHOWN
2. SEE DETAIL D3 ON SHEET 10-A-203 FOR CONTROL JOINT CONDITION AT
LOOSE LINTELS
3. PROVIDE SEALANT COLOR TRANSITIONS TO MATCH ADJACENT BRICK
OR CMU BLOCK ALONG LENGTH OF MASONRY CONTROL JOINT.
4. SEE DETAIL C3 ON SHEET 10-A-531 FOR WATERPROOFING CONDITION AT
LOOSE LINTELS AND MASONRY TIES
ABB.5CC.5DE
8’0 4’ 16’
SCALE:1/8"=1’
GENERAL NOTES
GRAPHIC SCALE
KEY NOTES
File details come from the government source that posted it. Updated .