AF39EC-1.PDF
PDF 901 KB Posted
- Attached to
- PA 206 HORSHAM HVAC SYSTEMS REPAIRS
- Solicitation number
- W912BU24R0001
About this file
This document contains an architectural drawing set and specifications for HVAC system repairs at the PA 206 Horsham facility along with the corresponding federal contract opportunity solicitation. The solicitation seeks proposals for HVAC repairs, including replacement of air handling units, fans, ductwork, controls and other components. The Department of the Army Corps of Engineers Engineering District in Philadelphia issued the solicitation with number W912BU24R0001 and an anticipated award date in 2023. The specifications provide detailed drawings and notes outlining the existing conditions and required repairs. Offerors will need to review the specifications thoroughly to understand the full scope of work.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W912BU24R0001 Amendment 0009_Cancellation.pdf | ||
| W912BU24R0001 Amendment 0005.pdf | ||
| AFC015-1.PDF | ||
| AF7200-1.PDF | ||
| AF7DA6-1.PDF | ||
| AF47CB-1.PDF | ||
| AF0F76-1.PDF | ||
| AF2040-1.PDF | ||
| AFRC55-1.PDF | ||
| 00-MP-1.PDF | ||
| 10-M-802.pdf | ||
| AF43EA-1.PDF | ||
| AF97A7-1.PDF | ||
| 00-M-801.pdf | ||
| AFD13B-1.PDF | ||
| AFF300-1.PDF | ||
| 00-M-808.pdf | ||
| AF1533-1.PDF | ||
| AF2872-1.PDF | ||
| 00-MH-2.PDF | ||
| AF7BD0-1.PDF | ||
| 00-M-201.pdf | ||
| AF9D55-1.PDF | ||
| 00-M-602.pdf | ||
| AF0EF7-1.PDF | ||
| AF4E85-1.PDF | ||
| AF1DF0-1.PDF | ||
| AFFC93-1.PDF | ||
| 10-MH-1.PDF | ||
| AF69FD-1.PDF | ||
| AFF200-1.PDF | ||
| 00-M-806.pdf | ||
| AF54B2-1.PDF | ||
| AFFC3F-1.PDF | ||
| AF377B-1.PDF | ||
| 00-MP-2.PDF | ||
| AF9D68-1.PDF | ||
| AFC2EA-1.PDF | ||
| AF1E68-1.PDF | ||
| AFA040-1.PDF | ||
| 10-M-800.pdf | ||
| AF8467-1.PDF | ||
| AFFB36-1.PDF | ||
| AF5A0C-1.PDF | ||
| 10-M-804.pdf | ||
| AF970C-1.PDF | ||
| AFRC55-3.PDF | ||
| 00-M-807.pdf | ||
| AF0467-1.PDF | ||
| AF2EB8-1.PDF |
Show 40 more
Latest 50 of 108 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
10-A-3011/8" = 1’ 0" A5
1/8" = 1’ 0" B5
BUILDING SECTION
BUILDING SECTION
O M
S A
M S
A B
U
IL
D
IN
G S
E C
T
IO
N S
BUILDING SECTION
B3
1/8" = 1’ 0"
8’0 4’ 16’
SCALE:1/8"=1’
8’0 4’ 16’
SCALE:1/8"=1’
8’0 4’ 16’
SCALE:1/8"=1’
AS-BUILT
S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5510-A-301.dgn
9/11/2012
9:33:42 AM
rifem
F O
R U
M S
T U
D
IO
I
N N
E R
B E
L T B
U S
IN
E S
S C
E N
T E
R D
R
S T L
O U
IS
M O
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
fi
US Army Corps of Engineers
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S I
D
L O
U
IS
V
IL
L E D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K Y
F S
B A
Z
C L
A Y
C O C
O N
S T
R U
C T
IO
N
.1
.1
-W
Q R -0
-R -0
P -1
1 3
C O
N C
E P
T D
E S
IG
N S
U B
M
IT
T A
L .1
.0
.1
.0
R
E V
IS
E D C
H A
R R
E T
T E C
O N
C E
P T S
U B
M
IT
T A
L
IN
T
E R
IM
S
U B
M
IT
T A
L .1
.1
.2
.1
A F
R C
-A -3
.d g n
/1
/2
F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L
A R
M Y R
E S
E R
V E T
R A
IN
IN
G C
E N
T E
R W
IL
L O
W G
R O
V E N
A V
A L A
IR
S
T A
T
IO
N W
Q R -0
-C -0
H O
R S
H A
M P
A
C
O R
R E
C T
E D F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L .0
.1
.1
.1
C
E R
T
IF
IE
D F
IN
A L S
U B
M
IT
T A
L
B R
IC
E Z
IC
K U
H R
FIRST FLOOR
100’-0"
T.O.S.
118’-1 1/2" T.O.S.
T.O.S. RIDGE
T.O.S.
T.O.S. RIDGE
T.O.S.
T.O.S. RIDGE
1 2 3 4 5
D C.5 C B.5 B E D C.5 C B.5 B A
23 17
10-A-303
A1
10-A-303
SIM
A1
10-A-302
SIM
A1
10-A-302
SIM
A31.5
131’-2 1/8" 131’-2 1/8"
131’-2 1/8"
113’-10 7/8"
113’-10 7/8"113’-10 7/8"
SHEET NOTES
61CLOSURE
SHINGLE ROOFING
RIGID ROOF INSULATION (R-30)
METAL ROOF DECK
MEMBRANE ROOFING
WOOD BLOCKING
AIR SPACE
RIGID INSULATION (R-12.5)
6" METAL STUDS AT 16" O.C.
BATT INSULATION (R-19)
METAL SOFFIT PANEL
BRICK VENEER
CONCRETE SLAB ON GRADE
AIR BARRIER
8" CMU
STEEL LINTEL
SCHEDULED CEILING
METAL FURRING CHANNEL
5/8" GYPSUM BOARD
PERIMETER INSULATION (R-10)
SECTIONAL OVERHEAD DOOR
METAL COPING
H.M. DOOR AND FRAME
MASONRY TIES AT 16" O.C.
METAL ROOF PANELS
METAL ROOF PURLIN
METAL WALL PANELS
EAVE STRUT
STEEL BASE ANGLE
BASE CLOSURE
STEEL FRAME BEYOND
ENDWALL POST BEYOND
CONTOUR GABLE TRIM
CAP FLASHING
HALF HEIGHT MASONRY
STARTER COURSE
STEEL GRATE PLATFORM -
SEE STRUCTURAL
FIRE TREATED OSB EXTERIOR
SHEATHING
CONCRETE SLAB W/ METAL DECK -
SEE STRUCTURAL DRAWINGS
CONCRETE FOUNDATION -
SEE STRUCTURAL DRAWINGS
ALUMINUM STORE FRONT
W/ LAMINATED INSULATING GLASS
STEEL BEAM -
SEE STRUCTURAL DRAWINGS
STEEL JOIST -
SEE STRUCTURAL DRAWINGS
METAL SIDEWALL GIRT VAPOR BARRIER
PRE-FINISHED SHEET MTL. FASCIA
PANEL WITH STIFFENING RIBS
LIGHT GA. CLIP
STL. ANGLE CLIP: SEE STRUCT.
PRE-FINISHED SHEET MTL. WALL
PANEL
ALUMINUM SUPPORT ANGLE - SEE
STRUCTURAL
PRE-ENGINEERED CANOPY WITH
METAL DOWN SPOUT
SEE DETAILS A4 AND C4 ON SHEET
00-A-533
6"X6" METAL GUTTER WITH 4"X5"
DOWN SPOUT
METAL OVERFLOW SCUPPER WITH
6"X6" DOWNSPOUT:
SEE C5 / D5 ON SHEET 00-A-531
STL. FRAME MAIN ENTRY CANOPY
EXTERIOR GYPSUM SHEATHING
ROOF INSULATION (R-20)
WALL INSULATION (R-15)
METAL LINER PANEL
LOUVER - SEE MECHANICAL
OPENING FOR MECHANICAL
EQUIPMENT - SEE MECHANICAL
SPLIT FACED CMU VENEER - USE
SMOOTH FACE AT CANOPIES
62 FIXED ALUMINUM WINDOW
PRECAST CONCRETE SILL
File details come from the government source that posted it. Updated .