Updated Drawing - GR00108C-102.pdf

PDF 417 KB Posted

Attached to
Garrison Dam Spillway Modification Project - Phase 2 Anchor Testing Federal contract opportunity
Solicitation number
W9128F25QA010
Issued by
Department of the Army Corps of Engineers Engineering District Omaha

About this file

This document is a construction site plan drawing for the Garrison Dam Spillway Modification Project - Phase 2 Anchor Investigation, prepared by the U.S. Army Corps of Engineers Omaha District. The technical drawing (Sheet C-102) details the anchor construction site plan, showing existing and proposed anchor test pad locations, laydown areas, office spaces, and parking zones. The drawing includes two key views: an existing site with a proposed laydown area on the north side, and a comprehensive view of existing and new anchor test pad locations, with precise measurements and a 3% slope specification. The plan indicates that final site disturbance limits require government approval, and proposed concrete pad locations are approximate and will be based on anchor installation sequencing and contractor work plan approval.

View the file

Other files for this federal contract opportunity

Other files attached to Garrison Dam Spillway Modification Project - Phase 2 Anchor Testing, newest first.
File Type Posted
Updated 15 Apr 2025 - Price Schedule for GDSM_PH2 Anchor Program.xlsx XLSX spreadsheet
4000 - 2025.04.15_Performance Work Statement for GDSM Anchor Inv Phase 2 FRS.pdf PDF
Amendment 0002 - W9128F25QA0100002.pdf PDF
Updated Drawing - GR00108C-101.pdf PDF
Updated Drawing - GR00108S-503.pdf PDF
Updated Drawing - GR00108S-101.pdf PDF
Amendment 0001 - W9128F25QA010.pdf PDF
Site Visit Attendance - Garrison Spillway Anchor Testing - 3 Apr 2025.pdf PDF
4007 - Attachment VII - Anchors Phase 2 Geotechnical Data Report_Volume I_20250318.pdf PDF
W9128F25QA010_Solicitation for GDSM Anchor Testing Phase 2.pdf PDF
3000 - SCA 2015-5383 Rev 24 23 Dec 2024 - McLean County ND.pdf PDF
4003 - Attachment III - Phase 2 Anchor Investiagion Drawings.pdf PDF
4004 - Attachment IV - Submittal Form 4025-R.pdf PDF
4006 - Attachment VI - GDSM Utilities Survey 2023.pdf PDF
4000 - 2025.03.17_Performance Work Statement for GDSM Anchor Inv Phase 2 FRS.pdf PDF
4005 - Attachment V - GDSM Anchors Phase 2 DIPP_20250318.pdf PDF
1000 - Instructions to Offerors with Provision 52.212-2 and Site Visit Info.pdf PDF
2000 - Price Schedule for GDSM_PH2 Anchor Program.pdf PDF
4001 - Attachment I - Submittal Items and Schedule.pdf PDF
4002 - Attachment II - Foundation Anchor Verification and Modified Extended Creep Test Steps.pdf PDF
Show all 20

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

45 17

45 17

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SU

BM

IT

TE

D B

Y:

C H

EC

KE

D B

Y:

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

IS

SU

E D

AT

E:

SI

ZE

M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E

SHEET ID

C :\T

EM

P\

N W

O

1\

LR

D _H

1E C

XG

H

9\ D

3\

G R

8C -1

.D

W G

:2

0:

A M

/1

5/

AE

C _N

C S_

5_ M

O N

O .C

TB

H

1E C

XG

H

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

O M

AH

A

D

IS

TR

IC

T

C

AP

IT

O L

AV

E

O M

AH

A, N E

FI

LE

N U

M

BE

R

FI

LE

N

AM

E:

G

AR

R

IS

O N

D

AM

, N O

R

TH

D

AK

O

TA

PH

AS

E

AN

C

H O

R

IN

VE

ST

IG

AT

IO

N

20' 40'0

N

N

40' 80'0

R . L

EI

G

H

W . P

ER

R

ET

T

F.

S

H

EF

FI

EL

D

R . L

EI

G

H

AM

EN

D M

EN

T

A

PR

EXISTING ANCHOR

TEST PAD AREA

EXISTING AND NEW ANCHOR TEST PAD LOCATIONSA1 SCALE:=1"=20'

EXISTING SITE WITH PROPOSED LAYDOWN AREA (NORTH SIDE)

SCALE: 1"-40"H1

EXISTING ANCHOR PADS

AN

C

H O

R C

O N

ST

R

U C

TI

O

N S

IT

E

PL

AN

C-102

EXISTING ACCESS ROAD

LAYDOWN, OFFICE, AND PARKING AREA

EXISTING ACCESS ROAD

SP-1 SP-2 SP-3

3% SLOPE MIN

3% S

LO

PE

PROPOSED 12' X 12'

ANCHOR TEST PADS, TYP.

SP-13 SP-9 SP-8

SP-10SP-12SP-11SP-14

SP-15

SP-7SP-6

SP-4 SP-5

PROPOSED LIMITS OF DISTRUBANCE

1. FINAL LIMITS OF SITE DISTURBANCE TO BE APPROVED

BY GOVERNMENT.

2. PROPOSED CONCRETE PAD LOCATIONS ARE

APPROXIMATE AND TO BE BASED ON ANCHOR

INSTALLATION SEQUENCING REQUIREMENTS AND

CONTRACTOR WORK PLAN APPROVAL.

NOTES:51.0'+ 51.0'+

51.0'+51.0'+

100.0'

51.0'+ 51.0'+ 51.0'+ 51.0'+

5.

0'

(T

YP

55.0'

93.3'

5.0' (TYP.)

51.0'+ 51.0'+ 51.0'+

Sheets and Views
C-102

File details come from the government source that posted it. Updated .