Solicitation_Attachment_5_-_NCANG_C-17_SIM_B-3_DRAWINGS_Vol3of3_-_Final.pdf

PDF 12 MB Posted

Attached to
Construct C-17 Simulator Facility Federal contract opportunity
Solicitation number
W91242-19-B-5002
Issued by
Department of the Army North Carolina Army National Guard

About this file

Drawings Vol 3 of 3

View the file

Other files for this federal contract opportunity

Other files attached to Construct C-17 Simulator Facility, newest first.
File Type Posted
Bid_Opening_Sign_in_sheet.pdf PDF
OF_1419_-_Bid_Opening_Abstract.pdf PDF
W91242-19-B-5002-0003.pdf PDF
Q&A__3.pdf PDF
CG-101_-_SITE_GRADING_&_DRAINAGE_PLAN_SIM_BLDG_Amendment_003.pdf PDF
A-504_-_EXTERIOR_WALL_SECTIONS_SIM_BLDG_Amendment_003.pdf PDF
A-505_-_EXTERIOR_WALL_SECTIONS_SIM_BLDG-Amendment_003.pdf PDF
S-505_-_STRUCTURAL_TYPICAL_DETAILS_SIM_BLDG_Amendment_003.pdf PDF
A-411_-_ENLARGED_PLANS_AND_INTERIOR_ELEVATIONS_SIM_BLDG_Amendment_003.pdf PDF
A-705_-_STOREFRONT_AND_CURTAINWALL_DETAILS_SIM_BLDG_Amendment_003.pdf PDF
A-511_-_EXTERIOR_WALL_DETAILS_SIM_BLDG_Amendment_003.pdf PDF
M-111-_HVAC_PLANS_SIM_BLDG_Amendment_003.pdf PDF
A-606_-_WINDOW_AND_STRUCTURED_POLYCARBONATE_WALL_PANEL_TYPES_SIM_BLDG_Amendment_003.pdf PDF
Q&A__2.pdf PDF
08_04_00_-_Blast_Resistance_SIM_BLDG_Amendment_002.pdf PDF
08_45_13_-_Structured-Polycarbonate-Panel_Assemblies_SIM_BLDG_Amendment_002.pdf PDF
W91242-19-B-5002-0002.pdf PDF
S-001_-_STRUCTURAL_GENERAL_NOTES_SIM_BLDG_Amendment_002.pdf PDF
CS-101_-_SITE_LAYOUT_PLAN_SIM_BLDG_Amendment_002.pdf PDF
C-502_-_Amendment_0001.pdf PDF
Q&A__1,_29_April_2019.pdf PDF
A-601_-_Amendment_0001.pdf PDF
W91242-19-B-5002-0001.pdf PDF
PreBidSlides_W91242-19-B-5002.ppt PPT presentation
Pre-Bid_Sign-in_Sheet.pdf PDF
Solicitation_Attachment_3_-_NCANG_C-17_SIM_B-3_DRAWINGS_Vol1of3_-_Final.pdf PDF
Solicitation_Attachment_11_-_Q&A_Simulator_Building_-_Previous_Solicitation.pdf PDF
Solicitation_Attachment_10_-_Visitor_Request_Worksheet.pdf PDF
Solicitation_Attachment_4_-_NCANG_C-17_SIM_B-3_DRAWINGS_Vol2of3_-_Final.pdf PDF
W91242-19-B-5002.pdf PDF
Solicitation_Attachment_8_-_Brand_Name_Justification_MONACO_Redacted.pdf PDF
Solicitation_Attachment_12_-_SOW_C-17_Sim_Facility.pdf PDF
Solicitation_Attachment_7_-_Brand_Name_Justification_ALERTON_Redacted.pdf PDF
Solicitation_Attachment_1_-_NCANG_C-17_SIM_B-3_SPECS_Vol_1of2_17-Aug-2018_-_Final.pdf PDF
Solicitation_Attachment_9_-_Pre-Bid_Conference_and_Site_Visit,_Bid_Drop-Off_Map1.pdf PDF
Solicitation_Attachment_2_-_NCANG_C-17_SIM_B-3_SPECS_Vol_2of2_17-Aug-2018_-_Final.pdf PDF
Solicitation_Attachment_6_-_NCANG_C-17_SIM_B-3_SUPPLEMENTAL_INFO_17-Aug-2018.pdf PDF
Show all 37

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

54321

D C

B A

/8

/2

:5

:5

P

M B

IM

/U

S

N o rt h C a ro lin a

A ir N a ti o n a l G u a rd

/N C

A N

G

C

F lig h t S im u la to r

A

R C

H

V

.r v t

NORTH CAROLINA AIR NATIONAL GUARD

C-17 FLIGHT SIMULATOR TRAINING FACILITY

145th AIRLIFT WING

CHARLOTTE-DOUGLAS IAP, NORTH CAROLINA

CONTRACT NO.: W9133L-15-D-0002

TASK ORDER NO.: D303

PN: FJRP159062

B-3 FINAL DESIGN SUBMISSION

17 AUGUST 2018

VOLUME 3 OF 3

GENERAL, PLUMBING, FIRE SUPPRESSION,

FIRE ALARM, ELECTRICAL,

TELECOMMUNICATIONS & SECURITY

DRAWING INDEX

IAINNFCOQUEIAEENTSCI

G E

O G

R A

PH

I AE PENE T

R A

M U

S

A I

R

N A T I O N A L

G

U A

R D

C I

V

I L

E N G I N E E R

I N

G

FJRP

159062

145TH AIRLIFT WING

NORTH CAROLINA AIR NATIONAL GUARD

CHARLOTTE-DOUGLAS IAP, NORTH CAROLINA

SCALE

DESIGNED BY

REVIEWED BY

DATE

AE PROJ. NO.

DRAWN BY

SHEET

PROJECT NO.

NCANG CIVIL ENGINEERING

REVISIONS

INITIALDESCRIPTIONDATEREV

CHARLOTTE-DOUGLAS IAP CHARLOTTE, NORTH CAROLINA

F6W71900

C-17 FLIGHT SIMULATOR TRAINING FACILITY

54321

D C

B A

08/17/2018

/1

/2

:4

:2

A

M B

IM

/U

S

N o rt h C a ro lin a

A ir N a ti o n a l G u a rd

/N C

A N

G

C

F lig h t S im u la to r

A

R C

H

V

.r v t

G-001

D. FLIPPEN

N. FREY

B. DYSON

GENERAL

DRAWING INDEX

FIRE SUPPRESSION

FX-001 GENERAL NOTES, SYMBOLS, AND ABBREVIATIONS

FX-100 OVERALL SITE PLAN

FX-111 C-17 FLIGHT SIMULATOR FLOOR PLAN

FX-501 DETAILS

FX-502 ENLARGED PLANS AND DETAILS

FIRE ALARM

FA-001 GENERAL NOTES, SYMBOLS, AND ABBREVIATIONS

FA-111 C-17 FLIGHT SIMULATOR FLOOR PLANS

FA-501 DETAILS AND RISER DIAGRAM

FA-503 SIM BUILDING MATRICES OF OPERATION

ELECTRICAL

E-001 ELECTRICAL SYMBOL LEGEND, ABBREVIATIONS, AND GENERAL NOTES.

ED101 C-17 FLIGHT SIMULATOR ELECTRICAL SITE DEMOLITION PLAN

ES111 C-17 FLIGHT SIMULATOR ELECTRICAL SITE PLAN

EL111 C-17 FLIGHT SIMULATOR LIGHTING PLANS

EP111 C-17 FLIGHT SIMULATOR POWER PLANS

EG111 C-17 FLIGHT SIMULATOR GROUNDING AND LIGHTNING PROTECTION PLAN

E-411 C-17 SIMULATOR BUILDING ENLARGED PLANS

E-501 ELECTRICAL DETAILS

E-502 ELECTRICAL DETAILS

E-503 ELECTRICAL DETAILS

E-504 ELECTRICAL DETAILS

E-611 C-17 FLIGHT SIMULATOR - ELECTRICAL SINGLE LINE DIAGRAM

E-612 C-17 FLIGHT SIMULATOR ELECTRICAL GROUNDING RISER DIAGRAM

E-701 LIGHTING FIXTURE SCHEDULE

E-702 FEEDER SCHEDULE

E-714 C-17 FLIGHT SIMULATOR PANEL SCHEDULES

E-715 C-17 FLIGHT SIMULATOR PANEL SCHEDULES

E-801 MECHANICAL EQUIPMENT SCHEDULE

E-802 PLUMBING AND ELECTRICAL EQUIPMENT SCHEDULES

TELECOMMUNICATIONS & SECURITY

T-001 TELECOM SYMBOLS, ABBREVIATIONS AND GENERAL NOTES

TS101 SITE PLAN

T-111 TELECOM C-17 FLIGHT SIMULATOR TELECOM PLANS

T-211 TELECOM RACK ELEVATIONS

T-212 CONDUIT ELEVATIONS

T-411 ENLARGED TELECOM PLANS

TS401 ENLARGED COMM HUT 72 PLAN AND DETAILS

T-501 TELECOM OUTLET DETAILS

T-502 TELECOM DETAILS

T-503 SECURITY DETAILS

T-504 TELECOM SITE DETAILS

T-611 TELECOM ONE-LINE DIAGRAMS

T-612 SECURITY ONE LINE DIAGRAMS

ARCHITECTURAL

A-001 GENERAL NOTES

A-111 C-17 FLIGHT SIMULATOR FLOOR PLANS

A-131 C-17 FLIGHT SIMULATOR REFLECTED CEILING PLANS

A-151 C-17 FLIGHT SIMULATOR ROOF PLAN

A-211 C-17 FLIGHT SIMULATOR EXTERIOR ELEVATIONS

A-311 C-17 FLIGHT SIMULATOR BUILDING SECTIONS

A-411 C-17 FLIGHT SIMULATOR ENLARGED PLANS AND INTERIOR ELEVATIONS

A-422 C-17 FLIGHT SIMULATOR ENLARGED STAIR PLAN, SECTION, AND DETAILS

A-423 C-17 FLIGHT SIMULATOR LADDER DETAILS

A-504 C-17 FLIGHT SIMULATOR EXTERIOR WALL SECTIONS

A-505 C-17 FLIGHT SIMULATOR EXTERIOR WALL SECTIONS

A-511 EXTERIOR WALL DETAILS

A-531 EXTERIOR DETAILS

A-532 EXTERIOR DETAILS

A-571 INTERIOR DETAILS

A-572 INTERIOR DETAILS

A-573 INTERIOR DETAILS

A-601 MATERIAL LEGEND

A-602 ROOM FINISH AND DOOR SCHEDULES

A-606 WINDOW AND STRUCTURED POLYCARBONATE WALL PANEL TYPES

A-701 PARTITION TYPES

A-702 DOOR DETAILS

A-703 DOOR DETAILS

A-705 STOREFRONT AND CURTAINWALL DETAILS

A-706 LOUVER TYPES AND DETAILS

A-711 TYPICAL PARTITION DETAILS

EQUIPMENT

Q-111 C-17 FLIGHT SIMULATOR FLOOR PLAN, SECTIONS, AND EQUIPMENT SCHEDULE

MECHANICAL

M-001 HVAC GENERAL NOTES, LEGENDS, AND ABBREVIATIONS

M-111 C-17 FLIGHT SIMULATOR HVAC PLANS

M-151 C-17 FLIGHT SIMULATOR HVAC ROOF PLAN

M-311 C-17 FLIGHT SIMULATOR HVAC SECTIONS

M-501 HVAC DETAILS

M-502 HVAC DETAILS

M-603 C-17 FLIGHT SIMULATOR HVAC SCHEDULES

M-701 HVAC CONTROL DIAGRAMS

M-702 HVAC BAS POINT FUNCTION SCHEDULE

PLUMBING

P-001 PLUMBING GENERAL NOTES, LEGEND, AND ABBREVIATIONS

P-121 C-17 FLIGHT SIMULATOR SANITARY PIPING PLAN

P-122 C-17 FLIGHT SIMULATOR WATER AND GAS PIPING PLAN

P-401 C-17 FLIGHT SIMULATOR ENLARGED PLANS

P-501 PLUMBING DETAILS

P-502 PLUMBING DETAILS

P-601 PLUMBING SCHEDULES

P-905 C-17 FLIGHT SIMULATOR SANITARY RISER DIAGRAM

P-906 C-17 FLIGHT SIMULATOR DOMESTIC WATER AND GAS PIPING RISER DIAGRAM

GENERAL

G-000 COVER

G-001 DRAWING INDEX

G-002 NOTES, ABBREVIATIONS, AND SYMBOLS

LIFE SAFETY

LS-001 GENERAL NOTES, SYMBOLS, AND ABBREVIATIONS

LS-002 CODE COMPLIANCE SITE PLAN

LS-111 C-17 FLIGHT SIMULATOR LIFE SAFETY FLOOR PLAN

CIVIL

C-001 NOTES, LEGENDS & ABBREVIATIONS

C-002 CONSTRUCTION PLAN

C-101 EXISTING CONDITIONS PLAN

CD-101 SITE DEMOLITION PLAN

CS-100 OVERALL SITE LAYOUT PLAN

CS-101 SITE LAYOUT PLAN

CG-101 SITE GRADING & DRAINAGE PLAN

CG-111 EROSION & SEDIMENT CONTROL PLAN - PHASE I

CG-121 EROSION & SEDIMENT CONTROL PLAN - PHASE II

CG-501 EROSION & SEDIMENT CONTROL NOTES AND DETAILS

CG-502 EROSION & SEDIMENT CONTROL NOTES AND DETAILS

CU-101 SITE UTILITY PLAN

CU-201 UTILITY PROFILES

CU-202 UTILITY PROFILES

CU-203 UTILITY PROFILES

CU-204 UTILITY PROFILES

C-501 CONSTRUCTION DETAILS

C-502 CONSTRUCTION DETAILS

C-503 CONSTRUCTION DETAILS

C-504 CONSTRUCTION DETAILS

C-505 CONSTRUCTION DETAILS

LANDSCAPE

L-101 LANDSCAPE PLANS

L-500 LANDSCAPE DETAILS

STRUCTURAL

S-001 STRUCTURAL GENERAL NOTES

S-002 WIND LOAD DIAGRAMS & ABBREVIATIONS

S-101 C-17 FLIGHT SIMULATOR OVERALL FOUNDATION PLAN

S-111 C-17 FLIGHT SIMULATOR FOUNDATION PLAN

S-121 C-17 SIMULATOR - OVERALL ROOF FRAMING PLAN

S-131 C-17 FLIGHT SIMULATOR EQUIPMENT PLATFORM & ROOF FRAMING PLANS

S-213 C-17 FLIGHT SIMULATOR BRACED FRAME AND GIRT ELEVATIONS

S-214 C-17 FLIGHT SIMULATOR CMU WALL ELEVATIONS

S-215 C-17 FLIGHT SIMULATOR CMU WALL ELEVATIONS

S-501 TYPICAL DETAILS

S-502 TYPICAL DETAILS

S-503 TYPICAL DETAILS

S-504 TYPICAL DETAILS

S-505 TYPICAL DETAILS

S-512 SECTIONS & DETAILS

S-524 SECTIONS & DETAILS

S-525 SECTIONS & DETAILS

S-526 SECTIONS & DETAILS

GENERAL SYMBOLS

MATCH LINE

KEYED NOTE

DOOR TAG

PARTITION TYPE TAG

(FIRST DIGIT INDICATES HOURLY FIRE RATING)

ELEVATION TARGET

NORTH ARROW

REVISION CLOUD

REVISION DESIGNATION TAG

WINDOW / LOUVER TYPE TAG

COLUMN REFERENCE

BREAK LINE

INDICATES PLAN NORTH

INTERIOR ELEVATION DESIGNATION

EXTERIOR ELEVATION DESIGNATION

SECTION / DETAIL DESIGNATION

DETAIL DESIGNATION

DRAWING /DETAIL LOCATION DESIGNATION

DRAWING/DETAIL TITLE

DRAWING NUMBER DESIGNATION

WHERE FIRST REFERENCED

DRAWING/DETAIL LIMITS

DRAWING / DETAIL LOCATION

DESIGNATION

DRAWING NUMBER DESIGNATION

WHERE FIRST REFERENCED

DRAWING / DETAIL LOCATION DESIGNATION

DRAWING NUMBER DESIGNATION WHERE SHOWN

DRAWING/DETAIL LOCATION DESIGNATION

DRAWING NUMBER DESIGNATION WHERE SHOWN

DRAWING NUMBER DESIGNATION WHERE SHOWN

DRAWING/DETAIL LOCATION DESIGNATION

DRAWING SCALE

ROOM TAG

GLASS TAGG1

A1

A-100

A1

A-100

A1

A-200

A1A-400

W1

N

1A

MATCH LINE

A1 / A-101

A1

DRAWING NAME

1/8" = 1'-0"

A-123

DRAWING DESIGNATION

ROOM NAME

ROOM NUMBER

ROOM NAME

ELEMENT ELEVATED

EL:XX' - XX"

PROJECT GENERAL NOTES

1. THIS DRAWING HAS GENERAL INFORMATION, NOT ALL MAY APPLY TO THIS PROJECT.

2. THE "OWNER" IS THE NORTH CAROLINA AIR NATIONAL GUARD. THE "ARCHITECT/ENGINEER" IS

JACOBS.

3. IF, AT ANY TIME, THE CONTRACTOR DISCOVERS A CONDITION WHICH CONFLICTS WITH THE

DRAWINGS AND/OR SPECIFICATION OR IF THE CONTRACTOR DISCOVERS AN UNCLEAR OR

MISLEADING DIRECTIVE GIVEN IN THE DRAWINGS OR SPECIFICATIONS, THE CONTRACTOR SHALL

BRING THE ISSUE IMMEDIATELY TO THE ATTENTION OF THE COR.

4. DO NOT SCALE THE DRAWINGS - FOLLOW WRITTEN DIMENSIONS ONLY.

5. FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO FABRICATION AND/OR

CONSTRUCTION.

6. ALL WORK INDICATED ON THE DRAWINGS IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR

UNLESS OTHERWISE NOTED.

7. KEYED NOTES LISTED ON DRAWINGS REFER ONLY TO THOSE KEYED NOTE SYMBOLS ASSOCIATED

WITH THE PARTICULAR DRAWING WHERE THE KEYED NOTES ARE LISTED.

8. RESPECTIVE PLUMBING, MECHANICAL, ELECTRICAL AND FIRE PROTECTION SUBCONTRACTORS

SHALL PROVIDE GENERAL CONTRACTOR WITH ALL REQUIRED ACCESS PANELS FOR GENERAL

CONTRACTOR TO INSTALL IN THE BUILDING.

9. ALL EXPOSED STEEL SHALL BE PAINTED UNLESS OTHERWISE NOTED.

10. THERE ARE NO ASBESTOS CONTAINING MATERIALS SPECIFIED AND THEY SHALL NOT BE USED ON

THIS PROJECT.

11. COORDINATE THE WORK OF ALL TRADES AND CHECK ALL DIMENSIONS. ALL DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF THE COR AND SHALL BE RESOLVED BEFORE PROCEEDING WITH

THE WORK.

12. THE STRUCTURAL, MECHANICAL, PLUMBING, FIRE PROTECTION, FIRE ALARM, ELECTRICAL, TELECOMMUNICATIONS, EQUIPMENT AND SECURITY DRAWINGS, ARE SUPPLEMENTARY TO THE

ARCHITECTURAL DRAWINGS. IF A DISCREPANCY EXISTS BETWEEN THE ARCHITECTURAL DRAWINGS AND ENGINEER'S DRAWINGS, SUCH DISCREPANCY SHALL BE BROUGHT TO THE COR'S ATTENTION IN WRITING PRIOR TO INSTALLATION OF SAID WORK. ANY WORK INSTALLED IN CONFLICT WITH THE

ARCHITECTURAL DRAWINGS SHALL BE CORRECTED BY THE CONTRACTOR AT CONTRACTOR'S

EXPENSE.

13. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED, BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR

DETAILS SHALL BE USED SUBJECT TO REVIEW BY THE ARCHITECT.

14. REFER TO FIRE SUPPRESSION AND ALARM DRAWINGS AND ELECTRICAL DRAWINGS FOR LOCATIONS

OF FIRE ALARM HORNS/STROBES, EXIT SIGNS, AND EMERGENCY LIGHTING.

15. RUBBER-TIRED EQUIPMENT SHALL BE USED FOR TRANSPORTING MATERIALS AND EQUIPMENT ON PAVED SURFACES AND WITHIN THE BUILDING. VEHICLES MOVING ON FLOOR SLABS SHALL HAVE TIRE

BOOTS. DUCT TAPE ON TIRES IS NOT ALLOWED.

16. EXPOSED CONCRETE FLOORS SHALL BE PROTECTED DURING CONSTRUCTION AND SHALL BE FREE OF ALL CONSTRUCTION MARKERS, STAINS, PAINTS, OIL, OR OTHER DEFECTS. PATCH, IF REQUIRED, PRIOR TO HARDENING AND SEALING.

17. CONFINE EQUIPMENT, STORAGE OF MATERIALS, AND OPERATIONS OF WORKERS TO LIMITS

INDICATED AND AS DIRECTED.

18. ALL TRUCKS HAULING DEBRIS FROM THE PROJECT SITE OR MATERIAL TO THE PROJECT SHALL BE

EQUIPPED WITH THE MEANS TO COVER LOADS AND WITH WATERPROOF TAILGATES WHICH SHUT

TIGHTLY AND DO NOT PERMIT THE DEBRIS TO SPILL FROM THE TAILGATE AREA. TRUCK BEDS SHALL BE SWEPT CLEAN AT THE TAILGATE BEFORE LEAVING FROM THE WORK AREA. SIDEBOARDS SHALL BE KEPT IN GOOD REPAIR. UNDER NO CIRCUMSTANCES WILL TRUCKS BE PERMITTED TO BE LOADED

GREATER THAN THE LEGAL LIMIT OR HIGHER THAN THE SIDEBOARDS.

19. OWNER WILL MAKE USE OF THE AREAS IN AND SURROUNDING THE CONSTRUCTION AREAS. EVERY EFFORT SHALL BE MADE TO MINIMIZE THE DISTURBANCE TO EMPLOYEES, PATRONS, AND TENANTS.

20. MANUFACTURER'S NAME AND/OR MODEL NUMBERS ARE BEING UTILIZED FOR BASIS OF DESIGN ONLY.

THE SPECIFICATION OUTLINES THE SPECIFIC CRITERIA FOR THE EQUIPMENT OR MATERIAL AND IS

NON-PROPRIETARY.

21. ALL UTILITY LINES IN PUBLIC AREAS SHALL BE ENCLOSED IN FLOOR, WALL OR CEILING

CONSTRUCTION UNLESS OTHERWISE NOTED.

22. MANUFACTURED MATERIALS, EQUIPMENT, ETC SHALL BE INSTALLED IN ACCORDANCE WITH THE

MANUFACTURER'S RECOMMENDATIONS, INSTRUCTIONS, AND ABA REQUIREMENTS UNLESS

OTHERWISE NOTED.

23. IF DRAWINGS IN THIS SET ARE NOT 30"x 42" THEY HAVE BEEN REVISED FROM THEIR ORIGINAL SIZE.

SCALES NOTED ON PLANS AND DETAILS ARE NO LONGER APPLICABLE.

24. PROVIDE A RED LINED "RECORD" CONSTRUCTION DOCUMENT SET AT THE SITE. THE OWNER

RESERVES THE RIGHT TO REVIEW THESE DOCUMENTS ON A DAILY BASIS.

25. LOCATE ALL UNDERGROUND UTILITIES, ETC. PRIOR TO THE START OF CONSTRUCTION.

26. KEEP MEANS OF EGRESS STAIRS AND CORRIDORS PROPERLY ILLUMINATED AND FREE OF

OBSTRUCTIONS AT ALL TIMES DURING CONSTRUCTION.

27. WORK SHALL CONFORM TO APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR

SHALL OBTAIN ALL REQUIRED BUILDING AND OCCUPANCY PERMITS.

28. ESTABLISH A SITE BENCHMARK FOR ALL SUBCONTRACTORS TO USE. ALL TRADES SHALL USE THE

SAME BENCHMARK

29. ITEMS INDICATED ON THE DRAWINGS AS "GFGI" MEANS GOVERNMENT FURNISHED AND GOVERNMENT

INSTALLED. COORDINATE WITH THE GOVERNMENT FOR THE REQUIRED POWER, PLUMBING, AND

OTHER REQUIRED UTILITIES AS APPLICABLE.

30. ITEMS INDICATED ON THE DRAWINGS AS "GFCI" MEANS GOVERNMENT FURNISHED AND CONTRACTOR

INSTALLED. COORDINATE WITH ALL SCOPE OF WORK.

31. ALL SUSPENDED ITEMS OF THE WORK EXCEEDING 31 POUNDS IN WEIGHT (EXCLUDING DISTRIBUTED SYSTEMS SUCH AS PIPING NETWORKS) SHALL BE ANCHORED TO RESIST A HORIZONTAL LOAD EQUAL TO 0.5 TIMES THE COMPONENT WEIGHT IN ACCORDANCE WITH UFC 4-010-01. THIS REQUIREMENT DOES NOT PRECLUDE REQUIREMENTS FOR SEISMIC ANCHORAGE IN ACCORDANCE WITH ASCE 7-05

AND THE PROJECT SPECIFICATIONS. FOR ADDITIONAL INFORMATION ON EQUIPMENT SUPPORT

FRAMING REFERENCE STRUCTURAL.

32. FOR LIFE SAFETY PLANS REFER TO LS-111.

33. FOR SIGNAGE SCHEDULE REFER TO SPECIFICATION SECTION 10 14 00 SIGNAGE. FOR TYPICAL SIGN

MOUNTING HEIGHTS REFER TO A-001.

34. DO NOT PAINT BUILDING GROUNDING CABLES.

35. PROVIDE SURFICIAL TERMITE TREATMENT UNDER ENTIRE FOOT PRINT OF THE C-17 FLIGHT

SIMULATOR FACILITY BUILDING.

36. ALL PENETRATIONS THROUGH SHEET METAL ROOF SHALL BE COORDINATED WITH THE SHEET METAL

ROOFING MANUFACTURER / INSTALLER TO ENSURE PENETRATIONS LAND BETWEEN

SEAMS/BATTENS. MOUNT ALL PIPING, EQUIPMENT, DUCTWORK, ETC. AS HIGH AS POSSIBLE IN ALL AREAS UNLESS OTHERWISE NOTED. ALL HANGER SUPPORTS SHALL BE ATTACHED TO STRUCTURAL

STEEL. NOTHING MAY BE SUPPORTED FROM ROOF DECK.

37. ANY OF THE SYMBOLS / MATERIAL REFERENCED ON THIS DRAWING MAY OR MAY NOT OCCUR AS A

PART OF THIS PROJECT AND ARE PROVIDED FOR REFERENCE ONLY.

GENERAL ABBREVIATIONS

ABA ARCHITECTURAL BARRIERS ACT

ACI AMERICAN CONCRETE INSTITUTE

ADA AMERICANS WITH DISABILITIES ACT

AFF ABOVE FINISHED FLOOR

AHU AIR HANDLING UNIT

AISC AMERICAN INSTITUTE OF STEEL

CONSTURCITON

ALUM ALUMINUM

ANSI AMERICAN NATIONAL STANDARDS

INSTITUTE

ASHRAE AMERICAN SOCIETY OF HEATING,

REFRIGERATION AND AIR

CONDITIONING ENGINEERS

ASTM AMERICAN SOCIETY OF TESTING AND

MATERIALS

AV AUDIO VISUAL

AWP ACOUSTIC WALL PANEL

BD BOARD

BLDG BUILDING

BM BEAM

BOT BOTTOM

CFCI CONTRACTOR FURNISHED,

CONTRACTOR INSTALLED

CJ CONTROL JOINT

CLG CEILING

CLR CLEAR

CMU CONCRETE MASONRY UNIT

COL COLUMN

COMM COMMUNICATION

CONC CONCRETE

CONT CONTINUOUS

COR CONTRACTING OFFICER'S

REPRESENTATIVE

CPT CARPET TILE

DIA DIAMETER

DWG DRAWING

E EAST

EA EACH

EJ EXPANSION JOINT

EL REFERENCE ELEVATION

ELEC ELECTRIC OR ELECTRICAL

EQ EQUAL

EWC ELECTRIC WATER COOLER

EXP EXPOSED

EXPAN EXPANSION

EXT EXTERIOR

EXTG EXISTING

FCO FLOOR CLEAN OUT

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FFE FURNITURE, FIXTURES AND

EQUIPMENT

FIN FINISH

FLR FLOOR

FM FACTORY MANUAL

GA GAGE OR GAUGE

GALV GALVANIZED

GFGI GOVERNMENT FURNISHED,

GOVERNMENT INSTALLED

GFCI GOVERNMENT FURNISHED,

CONTRACTOR INSTALLED

GL GLASS

GYP GYPSUM

OA OVERALL

OC ON CENTER

OFD OVERFLOW DRAIN

OH OPPOSITE HAND

OLI OPTIONAL LINE ITEM

OPNG OPENING

OPP OPPOSITE

PART PARTITION

PH PHASE

PLAM PLASTIC LAMINATE

PLAS PLASTIC OR PLASTER

PLBG PLUMBING

PLYWD PLYWOOD

PREFAB PREFABRICATED

PRESS PRESSURE

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PTD PAINTED

PVC POLYVINYL CHLORIDE

QT QUARRY TILE

R RISER

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

REBAR REINFORCED STEEL BAR

REF REFERENCE

REQ'D REQUIRED

RM ROOM

RO ROUGH OPENING

SCHED SCHEDULE

SHT SHEET

SIM SIMILAR

SMACNA SHEET METAL AND AIR

CONDITIONING CONTRACTORS

NATIONAL ASSOCIATION

SPEC SPECIFICATION(S)

SQ SQUARE

SF SQUARE FOOT

SS STAINLESS STEEL

STC SOUND TRANSMISSION CLASS

STL STEEL

STOR STORAGE

STRUCT STRUCTURAL

T TREAD

TELECOM TELECOMMUNICATIONS

THK THICK OR THICKNESS

TOC TOP OF CONCRETE

TBD TO BE DETERMINED

TCNA TILE COUNCIL OF NORTH

AMERICA

TOS TOP OF SLAB

TPO THERMOPLASTIC POLYOLEFIN

TYP TYPICAL

UL UNDERWRITERS LABORATORIES

UON UNLESS OTHERWISE NOTED

V VOLTS

VCT VINYL COMPOSITE TILE

VERT VERTICAL

VEST VESTIBULE

VIF VERIFY IN FIELD

VTR VENT THROUGH ROOF

WD WOOD

WR WATER RESISTANT

WWF WELDED WIRE FABRIC

HD HEAD

HDPE HIGH DENSITY POLYETHYLENE

HDW HARDWARE

HT HEIGHT

HORIZ HORIZONTAL

HVAC HEATING, VENTILATION AND AIR

CONDITIONING

IBC INTERNATIONAL BUILDING CODE

INSUL INSULATION

IT INFORMATION TECHNOLOGY

JAN JANITOR

JT JOINT

LAM LAMINATE

MAX MAXIMUM

MDF MEDIUM DENSITY FIBERBOARD

MECH MECHANICAL

MET METAL

MFR MANUFACTURER

MIN MINIMUM

MISC MISCELLANEOUS

MO MASONRY OPENING

N NORTH

N/A NOT APPLICABLE

NEC NATIONAL ELECTRIC CODE

NEMA NATIONAL ELECTRIC

MANUFACTURERS ASSOCIATION

NGB NATIONAL GUARD BUREAU

NFPA NATIONAL FIRE PROTECTION

ASSOCIATION

NIC NOT IN CONTRACT

MATERIAL LEGEND

STEEL

THERMAL INSULATION (BATT)

THERMAL INSULATION (RIGID)

GYPSUM BOARD

CONCRETE

EARTH

GRANULAR FILL

ACOUSTICAL PANEL CEILING

WOOD ROUGH

CMU

WOOD BLOCKING, SHIM

PARTICLEBOARD OR PLYWOOD

GLASS

CARPET

SOLID SURFACE MATERIAL

LOCATION MAP

PROJECT SITE

NOT TO SCALE

PROJECT SITE - C-17 SIMULATOR

NOT TO SCALE

PROJECT LOCATION

OPTIONAL LINE ITEMS (OLI) GENERAL NOTES

1. FLIGHT SIMULATOR BUILDING CRANE - REFER TO Q-111 FOR INFORMATION

2. DEMOUNTABLE PARTITIONS - REFER TO B1 / A-111 FOR INFORMATION

IAINNFCOQUEIAEENTSCI

G E

O G

R A

PH

I AE PENE T

R A

M U

S

A I

R

N A T I O N A L

G

U A

R D

C I

V

I L

E N G I N E E R

I N

G

FJRP

159062

145TH AIRLIFT WING

NORTH CAROLINA AIR NATIONAL GUARD

CHARLOTTE-DOUGLAS IAP, NORTH CAROLINA

SCALE

DESIGNED BY

REVIEWED BY

DATE

AE PROJ. NO.

DRAWN BY

SHEET

PROJECT NO.

NCANG CIVIL ENGINEERING

REVISIONS

INITIALDESCRIPTIONDATEREV

CHARLOTTE-DOUGLAS IAP CHARLOTTE, NORTH CAROLINA

F6W71900

C-17 FLIGHT SIMULATOR TRAINING FACILITY

54321

D C

B A

08/17/2018 12" = 1'-0"

/8

/2

:5

:1

P

M B

IM

/U

S

N o rt h C a ro lin a

A ir N a ti o n a l G u a rd

/N C

A N

G

C

F lig h t S im u la to r

A

R C

H

V

.r v t

G-002

D. FLIPPEN

N. FREY

B. DYSON

GENERAL

NOTES, ABBREVIATIONS,

AND SYMBOLS

N

N

VENT THROUGH ROOF - DIAGRAMMATIC (VTR)

WATER HAMMER ARRESTOR (WHA)

'A'

DOMESTIC COLD WATER

DOMESTIC HOT WATER (110°F OR 140°F)

DOMESTIC HOT WATER RETURN

AIR GAP FITTING

UNION

WALL HYDRANT (WH)

HOSE BIBB (HB)

SANITARY VENT

NATURAL GAS G

KEYNOTE REFERENCE

WALL CLEANOUTWCO

CLEANOUT PLUGCOP

SANITARY RISER DESIGNATION

VENT RISER DESIGNATION

SANITARY SEWER

FLOOR DRAIN WITH DEEP SEAL P-TRAPFD

CLEANOUT, YARD TYPE

YCO

CLEANOUT, FLOOR TYPE

FCO

CLEANOUT

CO

BRANCH SIDE CONNECTION

BRANCH TOP CONNECTION

BRANCH BOTTOM CONNECTION

LIMIT OF DEMOLITION WORK

POINT OF CONNECTION

FLOOR DRAIN WITH TRAP PRIMERFD

TP

GREASE DRAINAGE / GREASE WASTEGS/GW

SS

STORM DRAIN - STORM WATER PRIMARY

OVERFLOW DRAIN (STORM WATER SECONDARY DRAIN)OD

SD

V

PIPE TURNING DOWN

PIPE TURNING UP

CONDENSATE DRAINCD

NON-POTABLE WATERNPW

S

V

WATER RISER DESIGNATIONW

BALL VALVE

WATER METER

CAPPED PIPE

CONCENTRIC REDUCER

DIRECTION OF FLOW

ECCENTRIC REDUCER

FLANGED CONNECTION

FLEXIBLE CONNECTION

FLOW METER

GLOBE VALVE

MANUAL AIR VENT

METERED BALANCING VALVE

W/PRESSURE TAPS

GAS COCK

PIPE SLEEVE

PRESSURE REDUCING VALVE

PRESSURE RELIEF VALVE

SQUARE HEAD COCK

STRAINER

STRAINER W/BLOW DOWN VALVE

THERMOMETER / THERMOSTAT

VACUUM BREAKER

SOLENOID VALVE.

AUTOMATIC AIR VENT

PRESSURE GAUGE

CHECK VALVE

2-WAY CONTROL VALVE

3-WAY CONTROL VALVE

IAINNFCOQUEIAEENTSCI

G E

O G

R A

PH

I AE PENE T

R A

M U

S

A I

R

N A T I O N A L

G

U A

R D

C I

V

I L

E N G I N E E R

I N

G

FJRP

159062

145TH AIRLIFT WING

NORTH CAROLINA AIR NATIONAL GUARD

CHARLOTTE-DOUGLAS IAP, NORTH CAROLINA

SCALE

DESIGNED BY

REVIEWED BY

DATE

AE PROJ. NO.

DRAWN BY

SHEET

PROJECT NO.

NCANG CIVIL ENGINEERING

REVISIONS

INITIALDESCRIPTIONDATEREV

CHARLOTTE-DOUGLAS IAP CHARLOTTE, NORTH CAROLINA

F6W71900

C-17 FLIGHT SIMULATOR TRAINING FACILITY

54321

D C

B A

08/17/2018 1/8" = 1'-0"

/8

/2

:1

:5

P

M B

IM

/U

S

N o rt h C a ro lin a A ir N a ti o n a l G u a rd /N

C A

N G

C

F lig h t S im u la to r

P L

U M

B

V

.r v t

P-001

J. STAMPER

N. MITCHELL

N. MITCHELL

PLUMBING

GENERAL NOTES,

LEGEND AND ABBREVIATIONS

ABBREVIATION DESCRIPTION

AC AIR CONDITIONING

ADA AMERICANS WITH DISABILITY ACT

AFF ABOVE FINISH FLOOR

APPROX APPROXIMATE

ARCH ARCHITECT

BA BREATHING AIR

BFF BELOW FINISHED FLOOR

BFP BACKFLOW PREVENTER

BLDG BUILDING

CA COMPRESSED AIR

CD CONDENSATE WASTE

CHW CHILLED WATER

CI CAST IRON

CLG COOLING OR CEILING

CO CLEANOUT

CONC CONCRETE

CW COLD WATER (DOMESTIC WATER)

DFU DRAIN FIXTURE UNIT

DIA DIAMETER

DN DOWN

DWG DRAWING

DWH DOMESTIC WATER HEATER

EP ELEVATOR PUMP

ET EXPANSION TANK

ETP ELECTRONIC TRAP PRIMER

EWC ELECTRIC WATER COOLER

EWS EYEWASH STATION

EWT ENTERING WATER TEMPERATURE

FCO FLOOR CLEANOUT

FD FLOOR DRAIN

FL FLOOR

FLEX CONN FLEXIBLE CONNECTION

FS FLOOR SINK

G GAS / NATURAL GAS

GA GAUGE

GAL GALLON

GALV GALVANIZED

GPH GALLONS PER HOUR

GPM GALLONS PER MINUTE

GT GREASE TRAP

GW GREASE WASTE

HB HOSE BIBB

HD HUB DRAIN

HP HORSEPOWER

HR HOSE REEL

HTR HEATER

HW HOT WATER

HWR HOT WATER HEATING RETURN

HWS HOT WATER HEATING SUPPLY

HX DOMESTIC HOT WATER HEAT EXCHANGER

HYD WALL HYDRANT

HZ HERTZ

I.E INVERT ELEVATION

IN. HG INCHES OF MERCURY

IPC INTERNATIONAL PLUMBING CODE

IWH INSTANTANEOUS WATER HEATER

KW KILOWATT

L LAVATORY

LP LIQUID PROPANE

LWT LEAVING WATER TEMPERATURE

MECH MECHANICAL

MISC MISCELLANEOUS

MS MOP SINK

NIC NOT IN CONTRACT

NTS NOT TO SCALE

OD OVERFLOOW-ROOF DRAIN

OS&Y OUTSIDE STEM AND YOKE

P PUMP

PH PHASE

PWO POWER WASH OUTLET

PWS POWER WASH STATION

RBFP REDUCED PRESSURE BACKFLOW PREVENTER

RCP RECIRCULATING PUMP/REFLECTED CEILING PLAN

RD ROOF DRAIN

RL RAIN LEADER

RPM REVOLUTIONS PER MINUTE

S SINK

SD STORM DRAIN

SH SHOWER

SP SUMP PUMP/SEWAGE PUMP

SQ. FT. SQUARE FEET

SS STAINLESS STEEL

SS SANITARY SEWER

ST STORAGE TANK

T TEMPERATURE

T&P TEMPERATURE AND PRESSURE

TDH TOTAL DYNAMIC HEAD

TMV THERMOSTATIC MIXING VALVE

TP TRAP PRIMER

TTVS THERMOSTATIC TEMPERING VALVE STATION

TYP TYPICAL

U URINAL

V VENT/VOLTAGE

VTR VENT THRU ROOF

W WASTE

WC WATER CLOSET

WCO WALL CLEANOUT

WFSU WATER FIXTURE UNIT

WH WATER HEATER

WHA WATER HAMMER ARRESTOR

WS WATER SOFTENER

ABBREVIATIONS VALVES AND ACCESSORIES

PLUMBING LEGEND

GENERAL NOTES

1. THE INTENT OF THESE DRAWINGS IS TO PROVIDE COMPLETE AND

PROPERLY FUNCTIONING PLUMBING SYSTEMS.

2. PLUMBING WORK ON THIS PROJECT SHALL BE INSTALLED IN

ACCORDANCE WITH THE DRAWINGS, SPECIFICATIONS, AND THE IPC-

2012.

3. COORDINATE ALL PLUMBING WORK WITH SITE CONDITIONS AND THE

WORK OF OTHER TRADES, VERIFY EXISTING SLOPES AND INVERT

ELEVATIONS PRIOR TO COMMENCEMENT OF WORK.

4. THE WORK REQUIRED SHALL INCLUDE THE FURNISHING OF ALL

MATERIALS, CUTTING, PATCHING, ADAPTING AND ALL OTHER

INCIDENTAL WORK, TOGETHER WITH SUCH TEMPORARY

CONNECTIONS AS MAY BE REQUIRED

5. HORIZONTAL VENT PIPING SHALL BE RUN ABOVE CEILING AND ALL

HORIZONTAL SANITARY PIPING SHALL RUN BELOW SLAB UNLESS

OTHERWISE NOTED.

6. PIPE PENETRATIONS THROUGH SLAB AND WALLS SHALL HAVE PIPE

SLEEVES WITH FIRE PROOF MATERIAL. CAULK ANNULAR SPACE

BETWEEN PIPE AND SLEEVE. PIPES THRU INTERIOR WALLS SHALL

HAVE ESCUTCHEONS. REFER TO LIFE SAFETY PLANS FOR LOCATIONS

OF ALL FIRE RATED WALLS.

7. PROVIDE ACCESS PANELS FOR ALL VALVES, WATER HAMMER

ARRESTERS AND OTHER PLUMBING SPECIALITIES LOCATED INSIDE

CHASES, BEHIND WALLS OR ABOVE UNACCESSIBLE CEILINGS.

8. THE DRAWINGS ARE DIAGRAMMATIC AND ARE INTENDED TO INDICATE

CAPACITY, SIZE, APPROXIMATE LOCATION, AND GENERAL

ARRANGEMENT, NOT THE SPECIFIC DETAILS OF CONSTRUCTION.

9. SANITARY PIPE 3" DIA AND GREATER SHALL RUN BELOW FLOOR SLAB

AT 1% UNLESS NOTED OTHERWISE. SANITARY PIPE LESS THAN 3" DIA

SHALL RUN BELOW FLOOR SLAB AT 2% UNLESS NOTED OTHERWISE.

10. REFER TO ARCHITECTURAL INTERIOR ELEVATION DRAWINGS, WHERE

THE ARCHITECT HAS DRAWN SUCH ELEVATIONS, FOR THE LOCATION

OF WALL MOUNTED DEVICES.

11. COORDINATE LOCATION OF FLOOR DRAINS AND TRENCH DRAINS WITH

THE ARCHITECTURAL AND STRUCTURAL DRAWINGS AND MECHANICAL

EQUIPMENT LOCATIONS PRIOR TO INSTALLATION OF DRAINS. PROVIDE

A RADIUS AROUND THE FLOOR DRAIN THAT SLOPES TOWARD THE

FLOOR DRAIN FROM THE FINISHED FLOOR ELEVATION TO A TOP OF

DRAIN ELEVATION BETWEEN 1/2" AND 3/4" BELOW FINISHED FLOOR.

THIS IS TYPICAL OF FLOOR DRAINS EXCEPT THOSE IN THE

RESTROOMS (UNLESS OTHERWISE NOTED), WHICH WILL BE FLUSH

WITH THE TOP OF THE SLAB. THE RADIUS AND RATE OF SLOPE IS TO

BE FIELD COORDINATED.

12. COORDINATE SLAB PENETRATIONS AND SLEEVES PRIOR TO EACH

CONCRETE POUR OR CORE DRILL.

13. PERFORM WORK IN ACCORDANCE WITH THE LATEST EDITIONS,

REVISIONS, AMENDMENTS, OR SUPPLEMENTS OF APPLICABLE

STATUTES, CODES, OR REGULATIONS OF LOCAL AUTHORITIES HAVING

JURISDICTION IN EFFECT ON THE DATE BIDS ARE RECEIVED.

14. WHERE APPROVAL CODES HAVE BEEN ESTABLISHED BY OSHA,

UNDERWRITERS LABORATORY, CODES, ANSI, ASME, ASA, ASHRAE,

ASTM, ARI, JIS, NEC, NFPA, SMACNA, TDSHS, OR THE FIRE INSURANCE

REGULATORY BODY, FOLLOW THESE STANDARDS WHETHER OR

NOT INDICATED ON THE DRAWINGS.

15. COORDINATE WORK WITH ARCHITECTURAL FEATURES AND

COORDINATE WORK SUCH THAT INTERFERENCE BETWEEN PIPING,

ELECTRICAL WORK, AND BUILDING STRUCTURE WILL BE AVOIDED.

16. PROVIDE THE ENTIRE SYSTEM AND ITS COMPONENT ITEMS OF

EQUIPMENT IN OPERATING CONDITION WITHOUT OBJECTIONABLE

VIBRATION OR NOISE.

17. PROVIDE WIRING FOR ELECTRICAL CONTROLS IN ACCORDANCE WITH

NFPA 70 (N.E.C.).

18. DO NOT SCALE THESE DRAWINGS FOR CONSTRUCTION PURPOSES.

19. CONTRACTOR TO MAKE FINAL CONNECTIONS TO EQUIPMENT.

20. MOUNTING AND ANCHORING OF MECHANICAL EQUIPMENT SHALL BE

DONE BY THE ACTUAL DIMENSIONS OF THE SELECTED EQUIPMENT.

21. ALL MECHANICAL EQUIPMENT AND ASSOCIATED PIPING SYSTEM

COMPONENTS INSTALLED OUTDOORS SHALL BE MOUNTED AND

ANCHORED PROPERLY TO WITHSTAND HURRICANES.

22. FIRESTOP ALL PENETRATIONS OF FIRE RATED WALLS AND FLOOR

SEPARATIONS.

23. SEE LIFE SAFETY PLANS FOR ALL RATED WALLS AND PARTITIONS. ALL

PENETRATIONS SHALL BE PROTECTED ACCORDINGLY.

24. ALL INTERNAL CONDENSATE DRAIN PIPING AND STORM DRAIN PIPING

SHALL BE INSULATED.

25. INTERRUPTIONS OF SERVICES SHALL BE COORDINATED WITH THE

OWNER AT LEAST 48 HOURS IN ADVANCE OF THE WORK BEING

PERFORMED. DISRUPTION TIME SHALL BE KEPT TO A MINIMUM.

26. UNLESS OTHERWISE INDICATED, ALL PIPING SHALL BE RUN IN

CONCEALED SPACES IN WALLS, IN CHASES OR BETWEEN CEILINGS

AND INSULATION ABOVE. PIPES SHALL BE RUN AT RIGHT ANGLES OR

PARALLEL LINES WITH BUILDING WALLS AND ROUTED WITH

STRUCTURAL MEMBERS IN EXPOSED AREAS.

27. VERIFY THE ITEMS TO BE FURNISHED FIT THE SPACE

AVAILABLE.VERIFY LOCATIONS OF ALL EXISTING SERVICES AND

CONNECTION POINTS. FIELD CONFIRM ALL PIPE SIZES AND

LOCATIONS, AND ALL DIMENSIONS AND ELEVATIONS.

28. PROVIDE DIELECTRIC UNIONS AS REQUIRED.

29. INSTALL FIXTURES, EQUIPMENT AND MATERIALS IN ACCORDANCE

WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS, AND

APPLICABLE CODES. INSTALL ADA FIXTURES AT THE HEIGHTS

PRESCRIBED BY THE CODE HAVING JURISDICTION. MAKE PROPER

PIPING CONNECTIONS TO FIXTURES AND EQUIPMENT EVEN THOUGH

BRANCH MAINS, ELBOWS AND CONNECTIONS ARE NOT SHOWN.

COORDINATE WITH ARCHITECTURAL DRAWINGS BEFORE

ROUGHING-IN PLUMBING FIXTURES. PROVIDE STOPS ON ALL

PLUMBING FIXTURE WATER SUPPLIES. SENSOR OPERATED FLUSH

VALVES SHALL BE MOUNTED AT A HEIGHT WHEREAS RAISED WATER

CLOSET SEATS SHALL NOT INTERFERE WITH FLUSH VALVE

OPERATION.

30. PROVIDE 4" HIGH (MIN.) CONCRETE HOUSEKEEPING PADS FOR ALL

FLOOR MOUNTED EQUIPMENT, PAD SHALL BE A MINIMUM OF 6"

LARGER IN ALL DIRECTIONS THAN THE EQUIPMENT.

31. LOCATE ALL VALVES ABOVE ACCESSIBLE CEILING WHERE POSSIBLE.

PROVIDE ACCESS DOORS FOR ALL CONCEALED VALVES IN

INACCESSIBLE LOCATIONS.

S6

SF

SE

S2

SA

S1

SB

S5

SC

SD

S4 S3

W-1A

U-1

W-1A

MS-1

WCO

WCO

WCO

CO-1

YCO

FD-1

CO-1

FD-1

W-1

WCO

L-1L-1

L-1 L-1

CO-1

EWC-1

VESTIBULE

S101

LOBBY

S102

CORRIDOR

S103

ADMIN / INSTRUCTORS

S105

SITE MANAGER

S106

CBT LEARNING CENTER

S107

TER

S112

MULTI-PURPOSE ROOM

S111

MAINTENANCE

WORKROOM

S121

HIGH VALUE STORAGE

S123

BRIEFING ROOM

S115

WEAPON SYSTEM

COMPUTER ROOM

S124

FIRE RISER ROOM

S126

B-CER

S128

WEAPON SYSTEM

TRAINER BAY

S127

LOADMASTER STATION

S129

SECURITY CHECK

POINT

S116

VTRAT

S119

CLASSIFIED BRIEFING

S118

CLASSIFIED BRIEFING

S117

JANITOR

S109

MEN

S110

WOMEN

S108

SK-1

1/

4" V

P-401

C4

WCO

INVERT ELEVATION

AT 38" BELOW

FINISHED FLOOR

3" VTR

3" S

3" S

3" S

3"S

3"S

3"S

3" S

4"S

3" VTR

W/ OFFSET

WCO

FD-1

3" S

3" S

FD-1

5 WH-1

S6

SF

SE

S2

SA

S1

SB

S5

SC

SD

S4 S3

FD-1

FD-1

CO-1

FD-11

3" VTR3" PVC VENT FROM

WATER HEATER

2" VTR

W/ OFFSET3

IAINNFCOQUEIAEENTSCI

G E

O G

R A

PH

I AE PENE T

R A

M U

S

A I

R

N A T I O N A L

G

U A

R D

C I

V

I L

E N G I N E E R

I N

G

N

FJRP

159062

145TH AIRLIFT WING

NORTH CAROLINA AIR NATIONAL GUARD

CHARLOTTE-DOUGLAS IAP, NORTH CAROLINA

SCALE

DESIGNED BY

REVIEWED BY

DATE

AE PROJ. NO.

DRAWN BY

SHEET

PROJECT NO.

NCANG CIVIL ENGINEERING

REVISIONS

INITIALDESCRIPTIONDATEREV

CHARLOTTE-DOUGLAS IAP CHARLOTTE, NORTH CAROLINA

F6W71900

C-17 FLIGHT SIMULATOR TRAINING FACILITY

54321

D C

B A

08/17/2018 1/8" = 1'-0"

/8

/2

:1

:1

P

M B

IM

/U

S

N o rt h C a ro lin a A ir N a ti o n a l G u a rd /N

C A

N G

C

F lig h t S im u la to r

P L

U M

B

V

.r v t

P-121

J. STAMPER

N. MITCHELL

N. MITCHELL

PLUMBING

C-17 FLIGHT SIMULATOR

SANITARY PIPING PLAN

1/8" = 1'-0"A1

PLUMBING FLOOR PLAN

1/8" = 1'-0"C3

MECHANICAL EQUIPMENT MEZZANINE PLAN

PLUMBING GENERAL NOTES

1. FOR GENERAL NOTES, LEGEND, AND ABBREVIATIONS REFER TO SHEET P-001.

1/8" = 1'-0"

24'4' 8' 16'

1/8" = 1'-0"

24'4' 8' 16'

1 COORDINATE FLOOR DRAIN LOCATION WITH ACTUAL EQUIPMENT INSTALLED

2 FOR CONTINUATION, REFER TO CIVIL DRAWINGS

3 COORDINATE FINAL LOCATION WITH EQUIPMENT INSTALLED ON ROOF. MAINTAIN A MINIMUM 10'

DISTANCE HORIZONTALLY FROM AIR INTAKES.

4 REFERENCE DETAIL C1 AND D4/P-501 FOR FD-1.

5 ROUTE (2) 3" PVC VENT PIPES FROM WATER HEATER UP TO CONCENTRIC VENT KIT AT ROOF.

KEY NOTES

SE

S2

SA

S1

SB

S5

SC

SD

S4 S3

MECHANICAL /

ELECTRICAL

S201

WEAPON SYSTEM

TRAINER BAY

S127

1" C

A

1"CA

CAR-1

AC-1

1" CA DOWN TO SERVE

WST BAY

HYD-1

S6

SF

SE

S2

SA

S1

SB

S5

SC

SD

S4 S3

W-1A

U-1

W-1AW-1

MS-1

L-1

L-1

WH-1

SK-1

1"CA

1" C

A

1/

2" C

W

1 1/4"G

VESTIBULE

S101

LOBBY

S102

CORRIDOR

S103

ADMIN / INSTRUCTORS

S105

SITE MANAGER

S106

CBT LEARNING CENTER

S107

TER

S112

MULTI-PURPOSE ROOM

S111

MAINTENANCE

WORKROOM

S121

HIGH VALUE STORAGE

S123

BRIEFING ROOM

S115

WEAPON SYSTEM

COMPUTER ROOM

S124

FIRE RISER ROOM

S126

B-CER

S128

WEAPON SYSTEM

TRAINER BAY

S127

LOADMASTER STATION

S129

SECURITY CHECK

POINT

S116

VTRAT

S119

CLASSIFIED BRIEFING

S118

CLASSIFIED BRIEFING

S117

JANITOR

S109

MEN

S110

WOMEN

S108

L-1

P-401

C3

HR-1

HR-1

HR-1

EWC-1

1" CA

1" C

A

1/2" HW

1/2" CW

1/2" CW

1/2" HW

1/2" HW

1/2" CW

3/ 4"

C

W3/4"HW

RISE UP

DROP DOWN

PROVIDE 1" CA OUTLET FOR

WST BAY AT THIS LOCATION

2" C

W

1/

4" G

BFP-1

1/ 2"

C W

1/ 2"

H W

HYD-1

HYD-1

HYD-1

3/4"CW

IAINNFCOQUEIAEENTSCI

G E

O G

R A

PH

I AE PENE T

R A

M U

S

A I

R

N A T I O N A L

G

U A

R D

C I

V

I L

E N G I N E E R

I N

G

N

FJRP

159062

145TH AIRLIFT WING

NORTH CAROLINA AIR NATIONAL GUARD

CHARLOTTE-DOUGLAS IAP, NORTH CAROLINA

SCALE

DESIGNED BY

REVIEWED BY

DATE

AE PROJ. NO.

DRAWN BY

SHEET

PROJECT NO.

NCANG CIVIL ENGINEERING

REVISIONS

INITIALDESCRIPTIONDATEREV

CHARLOTTE-DOUGLAS IAP CHARLOTTE, NORTH CAROLINA

F6W71900

C-17 FLIGHT SIMULATOR TRAINING FACILITY

54321

D C

B A

08/17/2018 1/8" = 1'-0"

/8

/2

:1

:2

P

M B

IM

/U

S

N o rt h C a ro lin a A ir N a ti o n a l G u a rd /N

C A

N G

C

F lig h t S im u la to r

P L

U M

B

V

.r v t

P-122

J. STAMPER

N. MITCHELL

N. MITCHELL

PLUMBING

C-17 FLIGHT SIMULATOR

WATER AND GAS PIPING PLAN

1/8" = 1'-0"C1

MECHANICAL EQUIPMENT PLATFORM PLAN

1/8" = 1'-0"A1

PLUMBING FLOOR PLAN

1 ROUTE 1" CA UP TO MECHANICAL EQUIPMENT PLATFORM ABOVE.

2 ROUTE 1" CA LINE DOWN TO MAINTENANCE WORKROOM.

3 PROVIDE ELECTRONIC WATER METER ON WALL. TIE INTO BUILDING AUTOMATION SYSTEM

(BAS).

4 PROVIDE GAS METER ON WALL. TIE INTO BUILDING AUTOMATION SYSTEM (BAS).

5 PROVIDE GAS FIRED TANKLESS INSTANTANEOUS WATER HEATER. MOUNT ON WALL. ROUTE

PRESSURE AND TEMPERATURE RELIEF LINE ALONG WALL AND TERMINATE 3" ABOVE MOP SINK.

PROVIDE 3" SUPPLY AND EXHAUST VENT WITH MANUFACTURER'S CONCENTRIC ROOF OUTLET

FOR WATER HEATER.

6 PROVIDE INTEGRAL DRYER WITH AIR COMPRESSOR.

7 GAS METER TO BE PROVIDED BY GAS COMPANY. MOUNT OUTSIDE ON CONCRETE PAD.

PROVIDE WITH STEP DOWN PRESSURE REGULATOR TO 7" W.C.

8 GAS PIPING SIZED BASED ON INTERNATIONAL FUEL GAS CODE. LENGTH 150 FT, PRESSURE

DROP 0.3" W.C., 120 CFH AND 0.60 SPECIFIC GRAVITY.

9 1" CA LINE DOWN WALL FROM MECHANICAL PLATFORM ABOVE WITH DISCONNECT AT END OF

LINE.

10 CONNECT 3/4" MAKE UP WATER TO CHILLED WATER SYSTEM. SEE HVAC PLANS FOR

CONTINUATION.

PLUMBING GENERAL NOTES

1. FOR GENERAL NOTES, LEGEND, AND ABBREVIATIONS REFER TO SHEET P-001.

1/8" = 1'-0"

24'4' 8' 16'

1/8" = 1'-0"

24'4' 8' 16'

HB-1

KEY NOTES

3/4" HW

2"CW

1/2" CW

1/2" HW

1/2" CW

1/2" HW

3/4"HW

3/4"CW

1/2" CW

1/2" HW 1/2" CW

1/2" HW

3/4" HW

3/4"HW

3/4" HW

3/4" CW

3/4" CW

1 1/4" G

1 1/2"CW

1/2" CW

1/2"HW

3/4"HW

W-1AU-1

W-1A

MS-1

W-1

L-1L-1

L-1L-1

WH-1

WOMEN

S108

CORRIDOR

S103

JANITOR

S109

MEN

S110

1/

2" C

W

W-1A

U-1

W-1A

MS-1

WCO

FD-1

CO-1

FD-1

W-1

WCO

L-1L-1

L-1L-1

WH-1

WCO

WOMEN

S108

CORRIDOR

S103

JANITOR

S109

MEN

S110

WCO

2" V

3" S

3" S

3"S 3"S

3" S

3"S

3" S

3" S

3"S

2"V

1/

4" V

3" VTR

W/ OFFSET

CO-1

IAINNFCOQUEIAEENTSCI

G E

O

GR

APH I A E PENE TR

AM

U S

A I R

N A T I ON A L

GU

AR

D

C I

V

I L

E N G I N E E R

I N

G

N

FJRP

159062

145TH AIRLIFT WING

NORTH CAROLINA AIR NATIONAL GUARD

CHARLOTTE-DOUGLAS IAP, NORTH CAROLINA

SCALE

DESIGNED BY

REVIEWED BY

DATE

AE PROJ. NO.

DRAWN BY

SHEET

PROJECT NO.

NCANG CIVIL ENGINEERING

REVISIONS

INITIALDESCRIPTIONDATEREV

CHARLOTTE-DOUGLAS IAP CHARLOTTE, NORTH CAROLINA

F6W71900

C-17 FLIGHT SIMULATOR TRAINING FACILITY

54321

D C

B A

08/17/2018 1/4" = 1'-0"

8/ 9/

:5

9:

P M

B

IM

U

S

N or th C ar ol in a

A ir

N at io na l G ua rd /N

C A

N G

C

F lig ht

S im ul at or

P

LU

M B

V

.r vt

P-401

J. STAMPER

N. MITCHELL

N. MITCHELL

PLUMBING

C-17 FLIGHT SIMULATOR

ENLARGED PLANS

PLUMBING GENERAL NOTES

1. FOR GENERAL NOTES, LEGEND, AND ABREVIATIONS REFER TO SHEET P-001.

1/4" = 1'-0"

P-122

C3

SIM BUILDING RESTROOMS DOMESTIC

ENLARGED PLAN

1/4" = 1'-0"

P-121

C4

SIM BUILDING RESTROOMS SANITARY

ENLARGED PLAN

1/4" = 1'-0"

2' 4' 8' 12' 0

1/4" = 1'-0"

2' 4' 8' 12'

UNISTRUT SHIELD FOR PIPE 3" AND

LARGER

DOUBLE NUTS OR LOCK

NUTS (TYP. FOR ALL

SUPPORTS) FLAT

WASHERS

PIPE ROLLER FOR

HW PIPE 3" AND

LARGER

PIPE CLAMP FOR

PIPE 2-1/2" &

SMALLER

PIPE

INSULATION

FOR 2-1/2" AND

SMALLER

GALVANIZED IRON SHEET

CLEVIS HANGER FOR SHIELD FOR PIPE

3" AND LARGER

INSULATION

PIPE (TYP.)

HANGER PROVIDE A SECTION OF HIGH

COMPRESSION STRENGTH INSULATION

AT EACH HANGER POINT. INSULATION

MAY BE HALF ROUND OR FULL ROUND

AND INSULATION SHALL EXTEND 2"

BEYOND GALV. SHIELD EACH WAY.

TYPICAL ALL SUPPORT TYPES.

NOTE: PROVIDE SPRING VIBRATION ISOLATORS ON ALL PIPING 3" OR LARGER (TYPICAL)

FLO

CAST IRON

RISER - LENGTH

AS REQUIRED

LONG SWEEP ELBOW

AT BEGINNING OF

RUN

NOTE: PROVIDE WALL CLEANOUT AT BASE OF ALL ROOF DRAINAGE DOWNSPOUTS. PROVIDE WALL CLEANOUT WHERE SHOWN ON PLUMBING FLOOR PLANS, AND ON SANITARY WASTE BRANCHES NOT SERVED WITH FLOOR CLEANOUT. MAXIMUM HEIGHT ABOVE FINISHED FLOOR 1.2m.

PIPE MAY EXTEND AS WASTE, VENT OR

DOWNSPOUT

CLEANOUT TEE WITH SCREWED

COUNTERSUNK PLUG. TAPERED

THREAD WITH TFE JOINT COMPOUND

WHERE CLEANOUT TEE IS CONCEALED IN

A CHASE OR PARTITION, PROVIDE COVER

AS SPECIFIED

1/8 BEND FITTING AND WYE FITTING

OR COMBINATION 1/8 BEND & WYE

FITTING

SEE PLANS FOR SIZE MAIN

AND ROUTING OF PIPING

HUB AT FLOOR

FINISHED FLOOR

LOCATE CLEANOUT FACE WITHIN 100 mm

OF WALL SURFACE, PROVIDE

EXTENSION AS REQUIRED

COLUMN OR PARTITION

AS SHOWN ON

PLUMBING FLOOR

FINISHED FLOOR FLOOR DRAIN

AND P-TRAP

PROVIDE TAIL

PIECE TYPE TRAP

PRIMER

PROVIDE PROTECTIVE

SLEEVE AT FLOOR

PENETRATION

1/2" TRAP PRIMER LINE ROUTED

BELOW FLOOR TO FLOOR DRAIN

(NO JOINTS BELOW GRADE)

FINISHED

WALL

WALL BAX

FLANGE

WALL CLAMP

(IF USED)

INLET

CONNECTION

INSIDE BACK OF

WALL

ALL QUICK DISCONNECT COUPLINGS AND

FITTINGS SHALL MATCH OWNER'S

EXISTING

EQUIPMENT AND SHALL BE VERIFIED SPEEDAIRE MODEL 42L01

AIRLINE FILTER/REGULATOR

5-150 PSI, MAX FLOW 140 CFM

BALL VALVE

1/2"

1/2" QUICK DISCONNECT

COUPLINGS

3/4"

FINISHED GRADE

4"ø LENGTH

TO SUIT

FLOW

SEE SITE UTILITY PLAN

FOR CONTINUATION

GRANULAR BACK FILL

HUB WITH

SOLID

TOP

CONCRETE PAD TO

ENCLOSE

ENTIRE CLEANOUT

6"6"

SHOCK ABSORBER, SEE

PLAN FOR DESIGNATION

BALL VALVE

REDUCE IN VERTICAL

AS INDICATED

WATER SUPPLY TO

EQUIPMENT, SEE PLAN

AND SCHEDULES

WATER

SUPPLY ABOVE

CEILING, SEE

PLAN

SHOCK ABSORBER, SEE

PLAN FOR DESIGNATION

BALL VALVE

REDUCE IN VERTICAL

AS INDICATED

FULL SIZE OF SHOCK

ABSORBER INLET

WATER

SUPPLY

ABOVE

CEILING, SEE

PLAN

SUPPLY AIR

MAY BE

POSITIONED

ABOVE CEILING

SHOCK ABSORBER, SEE

PLAN FOR DESIGNATION

BALL VALVE

CW HEADER WITHIN

CHASE, SEE PLAN

FINAL FIXTURE SERVED

NOTE: SHOCK ABSORBERS INSTALLED ABOVE CEILING SHALL BE POSTIONED IN ACCESSIBLE LOCATIONS WITH ACCESS PANELS PROVIDED AS NEEDED. ALL SHOCK ABSORBERS INSTALLED WITHIN WALLS OR CHASES SHALL BE PROVIDED WITH ACCESS PANELS TO ALLOW FOR VALVE CLOSURE AND REMOVAL OF SHOCK ABSORBER.

WATER SUPPLY TO

EQUIPMENT, SEE

PLAN

EXTERIOR

WALL

ESCUTCHEON

SEDIMENT TRAP

GAS METER

BY GAS

UTILITY

COMPANY

CONCRETE PAD

REF CIVIL

DRAWINGS

1 1/4" (7 IN. W.C.)

GAS LINE TO

BUILDING

SYSTEMS

UNION, TYP GAS COCK,

LOCKING TYPE BY-PASS IF REQUIRED

BY GAS UTILITY

COMPANY

GAS PRESSURE REGULATOR

REDUCE TO 7 IN. W.C.

BUILDING PRESSURE

EMERGENCY GAS

CONNECTION

GAS COCK, TYP

FINISH GRADE

HIGH PRESSURE SERVICE

LINE AND METER BY GAS

UTILITY COMPANY REF CIVIL

DWGS FOR CONTINUATIONNOTES:

1. REGULATORS SHALL BE SIZED TO SUPPLY THE BUILDING

WITH 127 CHF AT 7 IN. W.C. DOWNSTREAM OF THE METER

2. RELIEF GAS VENT SHALL BE PROVIDED.

3. INSTALLATION SHALL COMPLY WITH UTILITY COMPANY

REQUIREMENTS.

PLUGGED TEE W/

BUSHING, TYP

EARTH

QUAKE SHUT

OFF VALVE

ELECTRONIC

GAS METER

WITH DIGITAL

OUTPUT FOR

ARNG USE

IAINNFCOQUEIAEENTSCI

G E

O G

R A

PH

I AE PENE T

R A

M U

S

A I

R

N A T I O N A L

G

U A

R D

C I

V

I L

E N G I N E E R

I N

G

FJRP

159062

145TH AIRLIFT WING

NORTH CAROLINA AIR NATIONAL GUARD

CHARLOTTE-DOUGLAS IAP, NORTH CAROLINA

SCALE

DESIGNED BY

REVIEWED BY

DATE

AE PROJ. NO.

DRAWN BY

SHEET

PROJECT NO.

NCANG CIVIL ENGINEERING

REVISIONS

INITIALDESCRIPTIONDATEREV

CHARLOTTE-DOUGLAS IAP CHARLOTTE, NORTH CAROLINA

F6W71900

C-17 FLIGHT SIMULATOR TRAINING FACILITY

54321

D C

B A

08/17/2018As indicated

/8

/2

:1

:3

P

M B

IM

/U

S

N o rt h C a ro lin a A ir N a ti o n a l G u a rd /N

C A

N G

C

F lig h t S im u la to r

P L

U M

B

V

.r v t

P-501

J. STAMPER

N. MITCHELL

N. MITCHELL

PLUMBING

DETAILS

NTSD1

TYPICAL PIPE SUPPORT DETAILS

NTSD2

WALL CLEANOUT DETAIL

NTSC1

TRAP PRIMER DETAIL

NTSC3

FREEZE PROOF WALL HYDRANT DETAIL

NTSB2

WALL MOUNTED COMPRESSED AIR DETAIL

NTSB3

2-WAY CLEANOUT DETAIL

NTSA2

WATER HAMMER ARRESTOR DETAIL

NTSA1

SIMULATION BUILDING GAS METER AND

REGULATOR DETAIL

NTSD3

NOT USED

NTSC2

NOT USED

NTSB1

NOT USED

NTSB4

NOT USED

NTSA3

NOT USED

NTSD4

NOT USED

12" DIRT LEG

REGULATOR/GAUGE

AIR LUBRICATOR

DRAIN VALVE ELEVATION

PLAN

1" AIR DROP

BALL VALVE

TYPE 1 (CA)

AIR FILTER WALL

QUICK COUPLER

CONNECTOR SIZE PER

SPEC. @ 48" AFF

OPTIONAL HARD PIPE TO

PNEUMATIC EQUIPEMENT

AS REQUIRED

TYP. PIPE SUPPORT TO

WALL OR STRUCTURE

3/4" x 1/2"

CONCENTRIC

REDUCER

3/4" 45° ELBOW

3/4" NIPPLE

3/4" BALL VALVE

AUTOMATIC MOISTURE

REMOVAL TRAP WITH

BOWL GUARD, PIPE TO

NEAREST HUB DRAIN (HD-1) OR

FLOOR DRAIN (FD-1).

COMPRESSED AIR MAIN

AC-1

AIR RECEIVER

WITH DRAIN

FILTER AND

FLOAT DRAIN

DIFFUSION

MANIFOLD

NOTES:

1. PROVIDE RECEIVER TANK MOUNTED PRESSURE RELIEF VALVE AND PRESSURE

GAGE.

2. PROVIDE CONTROL PANEL WITH ALTERNATING RELAY WHICH AUTOMATICALLY

ALTERNATES PRIMARY COMPRESSOR ON SUCCESSIVE START-UPS.

3. PIPE SLOPE TO BE TOWARD DRAINS, COLLECTORS AND DIRT LEGS.

COMPRESSED AIR

MAIN AT 125 PSI

TO BUILDING

SYSTEM

PRESSURE REGULATOR

SET AT 125 PSI MAXIMUM

WITH FULL-SIZE BYPASS

FLOOR DRAIN

TO AIR

RECEIVER

COMPRESSOR

WITH

INTEGRAL

DRYER

FLEX CONN WITH

CORRUGATED METAL

CORE AND WIRE BRAID

COVER

TO EQUIPMENT

4" CONCRETE

HOUSKEEPING PAD

IAINNFCOQUEIAEENTSCI

G E

O

GR

APH I A E PENE TR

AM

U S

A I R

N A T I ON A L

GU

AR

D

C I

V

I L

E N G I N E E R

I N

G

FJRP

159062

145TH AIRLIFT WING

NORTH CAROLINA AIR NATIONAL GUARD

CHARLOTTE-DOUGLAS IAP, NORTH CAROLINA

SCALE

DESIGNED BY

REVIEWED BY

DATE

AE PROJ. NO.

DRAWN BY

SHEET

PROJECT NO.

NCANG CIVIL ENGINEERING

REVISIONS

INITIALDESCRIPTIONDATEREV

CHARLOTTE-DOUGLAS IAP CHARLOTTE, NORTH CAROLINA

F6W71900

C-17 FLIGHT SIMULATOR TRAINING FACILITY

54321

D C

B A

08/17/2018 12" = 1'-0"

8/ 9/

:5

9:

P M

B

IM

U

S

N or th C ar ol in a

A ir

N at io na l G ua rd /N

C A

N G

C

F lig ht

S im ul at or

P

LU

M B

V

.r vt

P-502

J. STAMPER

N. MITCHELL

N. MITCHELL

PLUMBING

DETAILS

NTSB2 COMPRESSED AIR OUTLET DETAIL

NTSB1 AUTOMATIC COMPRESSED AIR DRAIN DETAIL

12" = 1'-0"A1 AIR COMPRESSOR DETAIL

IAINNFCOQUEIAEENTSCI

G E

O G

R A

PH

I AE PENE T

R A

M U

S

A I

R

N A T I O N A L

G

U A

R D

C I

V

I L

E N G I N E E R

I N

G

FJRP

159062

145TH AIRLIFT WING

NORTH CAROLINA AIR NATIONAL GUARD

CHARLOTTE-DOUGLAS IAP, NORTH CAROLINA

SCALE

DESIGNED BY

REVIEWED BY

DATE

AE PROJ. NO.

DRAWN BY

SHEET

PROJECT NO.

NCANG CIVIL ENGINEERING

REVISIONS

INITIALDESCRIPTIONDATEREV

CHARLOTTE-DOUGLAS IAP CHARLOTTE, NORTH CAROLINA

F6W71900

C-17 FLIGHT SIMULATOR TRAINING FACILITY

54321

D C

B A

08/17/2018

/8

/2

:1

:4

P

M B

IM

/U

S

N o rt h C a ro lin a A ir N a ti o n a l G u a rd /N

C A

N G

C

F lig h t S im u la to r

P L

U M

B

V

.r v t

P-601

J. STAMPER

N. MITCHELL

N. MITCHELL

PLUMBING

SCHEDULES

MARK

FLOOR DRAIN

SERVICE WASTE

3" 3"

VENTTRAP BASIS OF DESIGN REMARKS

DRAIN SCHEDULE

ZURN MODEL

Z415B

* PLUMBING CONNECTION SIZES AS SHOWN ON SCHEDULE UNLESS OTHERWISE SPECIFIED ON PLAN DRAWINGS.

WITH TRAP PRIMER CONNECTION AND

SEDIMENT BUCKET. SEE DETAIL C1/P-501.1-1/2"FD-1

REMARKSMARK

BASIS OF DESIGN

MANUFACTURER MODEL NO.

SERVES

CAPACITY

CFM VOLT PHASE

MOTOR

Hz kW

AIR COMPRESSOR SCHEDULE

AC-1 SIMULATION

CA

30 7.53 60

MANUFACTURER MODEL LENGTH

FT

HOSE REEL SCHEDULE

MARK

HR-1 DP5435

MAX PRESSURE

PSI

35 300REELCRAFT

HOSE INLET

IN

1/2"

DRIVE

SPRING

RETRACTABLE

NOTES

NOTE:

1. RATED FOR 50,00 POUND PROOF LOAD AND 250 PSI PRESSURE LOAD.

NOTE:

1. PROVIDE WITH COALESCING FILTER, AFTER COOLER, AND VARIABLE FREQUENCY DRIVE FOR ALL COMPRESSORS.

TYPE

480ATLAS COPCO

OIL INJECTED

ROTARY SCREW

PLUMBING FIXTURE CONNECTION SCHEDULE

MARK DESCRIPTION

CONNECTION ELECTRICAL

V/PH/HZ BASIS OF DESIGN REMARKSW V CW HW

W-1 WATER CLOSET

WALL MOUNTED

(WALL OUTLET) - FLUSH VALVE

4" 2" 1" - - AMERICAN STANDARD MODEL # 2856.111. AFWALL FLOWISE 1.1

GPF FLUSHOMETER TOILET SYSTEM WITH EVERCLEAN EXPOSED

TOP SPUD BOWL. AMERICAN STANDARD MANUAL FLUSH VALVE

MODEL # 6047.111.002. TOILET SEAT OLSONITE MODEL 95SS OPEN

FRONT, ELONGATED BOWL, SELF-SUSTAINING HINGE. ZURN MODEL

Z1204-ND4 CARRIER FOR BACK TO BACK FIXTURES, Z1204-N4 FOR

SINGLE FIXTURE

SEE ARCHITECTURAL DWG'S

FOR MOUNTING HEIGHTS

OF STANDARD AND ADA

FIXTURES.

W-1A WATER CLOSET (ADA)

WALL MOUNTED

(WALL OUTLET) - FLUSH VALVE

4" 2" 1" - - AMERICAN STANDARD MODEL # 2856.111. AFWALL FLOWISE 1.1

GPF FLUSHOMETER TOILET SYSTEM WITH EVERCLEAN EXPOSED

TOP SPUD BOWL. AMERICAN STANDARD MANUAL FLUSH VALVE

MODEL # 6047.111.002 TOILET SEAT OLSONITE MODEL 95SS OPEN

FRONT, ELONGATED BOWL, SELF-SUSTAINING HINGE. ZURN MODEL

Z1204-ND4 CARRIER FOR BACK TO BACK FIXTURES, Z1204-N4 FOR

SINGLE FIXTURE

SEE ARCHITECTURAL DWG'S

FOR MOUNTING HEIGHTS

OF STANDARD AND ADA

FIXTURES.

L-1 LAVATORY (ADA)

(WALL HUNG)

1-1/2" 2" 1/2" 1/2" - AMERICAN STANDARD MODEL # 0356.421 LUCERNE WALL-HUNG

LAVATORY. AMERICAN STANDARD FAUCET MODEL 7420.101 SINGLE

CONTROL.SINK 0.5 GPM AERATOR; WATTS LFMMV MIXING VALVE OR

EQUAL FOR UP TO TWO SINKS, GRID STRAINER.

PROVIDE INSULATION

FOR PLUMBING PIPING

UNDER LAV.

U-1 URINAL (ADA)

WALL HUNG

FLUSH VALVE

2" 2" 3/4" - - AMERICAN STANDARD MAYBROOK UNIVERSAL URINAL, 0.125 GPF,

TOP SPUD, WALL MOUNTED; WITH 0.125 GPF MANUAL FLUSH VALVE

#6045.013.002, 3/4"; ZURN Z-1222 WALL CARRIER.

SEE ARCHITECTURAL DWG'S

FOR MOUNTING HEIGHTS

OF STANDARD AND ADA

FIXTURES.

SK-1 PANTRY

SINK

2" 1/2" 1/2" 1/2" - ELKAY LUSTERTONE LRQ1716 17x16 SINGLE BOWL SINK, 1

FAUCET HOLE; ELKAY 4175.300.FI5

MAUAL PULL DOWN FAUCET, 1.5 GPM.

EWC-1 ELEC.

DRINKING FOUNTAIN

(BI-LEVEL)

1-1/2" 1-1/2" 1/2" - 115/1/60 ELKAY LVRCGRNTL8WSK HIGH-EFFICIENCY BI-LEVEL ELECTRIC

WATER COOLER, 8 GPH; ADA DESIGN; INTEGRATED 1.1 GPM

BOTTLE FILLING STATION; SELF CONTAINED COOLING SYSTEM.

SEE ARCHITECTURAL DWG'S

FOR MOUNTING HEIGHTS

OF STANDARD AND ADA

FIXTURES.

MS-1 MOP

SINK

3" 1-1/2" 1/2" 1/2" - FIAT: TSBC 1611 SERIES ; NEO CORNER MODEL; STAINLESS

STEEL THRESHOLD; WITH AMERICAN STANDARD 8354.112

FAUCET EXPOSED YOKE WALL MOUNT UTILITY FAUCET.

STRAINER; MOP BRACKET.

HYD-1 WALL HYDRANT

(EXTERIOR WITH

VACUUM BREAKER)

- - 3/4" - - ZURN 1320 ECOLOTROL NON-FREEZE WALL HYDRANT -

TP-1 TRAP PRIMER - - 1/2" - - ZURN 1022-XL TRAP PRIMER -

CO-1 FLOOR CLEANOUT - - - - - ZURN ZB-1400 FLOOR CLEANOUT. SIZE SHALL BE SAME AS

LINE SIZE

YCO YARD CLEANOUT - - - - - ZURN ZS-1400 CLEANOUT SIZE SHALL BE SAME AS

LINE SIZE, HEAVY DUTY TOP

WCO WALL CLEANOUT - - - - - ZURN ZB-1441 WALL CLEANOUT WITH ACCESS COVER. SIZE SHALL BE SAME AS

LINE SIZE

HB-1 INTERIOR HOSE BIBB - - 3/4" - - ZURN MODEL # Z1341XL HOSE BIBB -

ETP-1 ELECTRONIC TRAP PRIMER - - 1/2" 1/2" 120/1/60 PRECISION PLUMBING PRODUCTS MINI-PRIME TRAP PRIMING

MANIFOLD

HP

PROVIDE WITH INTEGRAL

DRYER

MARK TYPE

AIR RECEIVER TANK SCHEDULE

PRESSURE

RATING

(PSI)

DIAMETER HEIGHT

VOLUME

(GAL)

LOCATION

CAR-1 VERTICAL 200 20 IN 49 IN 60FLIGHT SIMULATOR

BUILDING

BASIS OF DESIGN

MANUFACTURER MODEL NO.

HANSON 20-VC-60-R

NOTE:

2. PROVIDE WITH WALL MOUNTING BRACKETS.

BACKFLOW PREVENTER SCHEDULE

MARK DESCRIPTION LOCATION SERVICE

MAXIMUM WORKING

PRESSURE (PSI) DIAMETER

MAXIMUM PRESSURE DROP

AT ACTUAL FLOW (PSI)

ACTUAL

FLOW (GPM)

BFP-1 DOUBLE CHECK

BACKFLOW PREVENTER

FLIGHT

SIMULATOR

DOMESTIC

WATER MAIN

175 2" 13 50

GA 7

FIXTURE

UNIT RATING

CONNECTION SIZE

TO SUPPLY PIPE

BASIS OF

DESIGN

WATER HAMMER ARRESTER SCHEDULE

MARK

WHA-1

WHA-2

WHA-3

1 - 11

12 - 32

61 - 113

1/2"

3/4"

1"

MODEL REMARKS

WILKINS 1250XL

WILKINS 1250XL

WILKINS 1250XL

INST. WATER HEATER

(NATURAL GAS)

A.O. SMITH MODEL # ATI-140H-N120/1/60

DESCRIPTIONMARK

ELECTRICAL

V/PH/HZ

BASIS OF DESIGN REMARKS

WATER HEATER SCHEDULE

NOTE:

1. PROVIDE WITH CONDENSATE NEUTRALIZATION KIT.

2. PROVIDE GAS WATER HEATERS WITH CONCENTRIC DIRECT VENTING KIT.

3. INSTALL WATER HEATERS IN COMPLIANCE WITH ALL MANUFACTURERS INSTALLATION REQUIREMENTS.

4. MOUNT WATER HEATER ON WALL AT 48" AFF.

1,2,3,4

LOCATION

JANITOR

S109

3/4" 3/4"

CW HW

CONNECTION

RECOVERY

60°F ∆T

4.0 GPM

EWT (°F)

LWT (°F)

MBH

(INPUT)

120 0.93

ENERGY

FACTOR

WH-1

REFER TO CIVIL PLANS

FOR CONTINUATION

3" VTR

1/

4" V

3" VTR

1 1/4"V 2"

V

1/

4" V

1 1/4"V1 1/4"V

3 "S

1/

4" V

3" S

1 1/4"V 2"

V

3" S

3" S

3"V

4" S

1 1/4"V

4" S

2"V

2" V

3" V

2" V

4"S

3"S

3"S

3"S

3"S

3"S

3"S

3"S

3"S

3"S

3" S

3"S

3" VTR

PROVIDE TRAP PRIMER

TO FLOOR DRAIN, SEE

DETAIL C1 SHEET P-501

PROVIDE TRAP PRIMER

TO FLOOR DRAIN, SEE

DETAIL C1 SHEET P-501

3"S

3"S

4"S

2"S

3"S

3' - 9

5' - 11"

27' - 4

44' - 1 0"

2' - 3"

WH-1

1 1/4"G

1 1/4"G

19' - 4"

4' - 5 19/32"

11' - 4"

11' - 7 3/16"

NOTES:

120 MBH TOTAL USAGE.

LONGEST PIPING RUN TO OVEN IS 750 FT.

INLET PRESSURE 7" W.C.

PRESSURE DROP 0.3" W.C.

SPECIFIC GRAVITY 0.60.

PIPING SIZING BASED ON INTERNATIONAL

FUEL GAS CODE

REFER TO CIVIL PLANS

FOR CONTINUATION

IAINNFCOQUEIAEENTSCI

G E

O G

R A

PH

I AE PENE T

R A

M U

S

A I

R

N A T I O N A L

G

U A

R D

C I

V

I L

E N G I N E E R

I N

G

FJRP

159062

145TH AIRLIFT WING

NORTH CAROLINA AIR NATIONAL GUARD

CHARLOTTE-DOUGLAS IAP, NORTH CAROLINA

SCALE

DESIGNED BY

REVIEWED BY

DATE

AE PROJ. NO.

DRAWN BY

SHEET

PROJECT NO.

NCANG CIVIL ENGINEERING

REVISIONS

INITIALDESCRIPTIONDATEREV

CHARLOTTE-DOUGLAS IAP CHARLOTTE, NORTH CAROLINA

F6W71900

C-17 FLIGHT SIMULATOR TRAINING FACILITY

54321

D C

B A

08/17/2018

/8

/2

:1

:5

P

M B

IM

/U

S

N o rt h C a ro lin a A ir N a ti o n a l G u a rd /N

C A

N G

C

F lig h t S im u la to r

P L

U M

B

V

.r v t

P-905

J. STAMPER

N. MITCHELL

N. MITCHELL

PLUMBING

C-17 FLIGHT SIMULATOR

SANITARY PIPING RISER DIAGRAM

A1

C-17 FLIGHT SIMULATOR SANITARY PIPING

RISER DIAGRAM

L-1 L-1

SK-1

EWC-1

FD-1

CO-1

FD-1

FD-1

WCO

MS-1

YCO

FD-1

WCO

CO-1

CO-1

L-1 L-1

WCO

WCO

W-1A

W-1A

U-1 W-1

WCO

C3

C-17 FLIGHT SIMULATOR

GAS PIPING RISER DIAGRAM

FD-1

WCO

FD-1

FD-1

WH-1

1 1/2"CW

REFER TO CIVIL PLANS

FOR CONTINUATION

1/2" HW

1/2" CW

1/2" CW

1/2" HW

1/2" CW

1/2" HW

3/4"HW

3/4"CW

1/2" CW

1/2" HW

1/2" HW

1/2" CW

WH-1

1 1/4"G

1/2" CW

1 1/2" CW

3/4" CW

1 1/2" CW

3/4" CW

3/4" HW

2" CW

3/4" HW

1 1/4"G

3/4" HW

1" CW

1" CW

1" CW

3/4"HW

1/2" HW1/2" CW

2"CW

1 1/4"G

2" C

W

1/ 4"

G

ELECTRONIC WATER

METER.

BFP-1

CONNECT 3/4" MAKE UP WATER TO

CHILLED WATER SYSTEM. SEE

HVAC PLANS FOR CONTINUATION.

1 1/4"G

2"CW

2"CW

1 1/4"G

3/4"CW

3/4"HW

SHUT OFF VALVE

SHUT OFF VALVE

1/2"HW

1/2"CW

3/4"CW

1/

4" G

2"CW

1 1/4"G

1"CW

3/4"CW

3/4"CW

3/ 4"

C W

3/ 4"

C W

IAINNFCOQUEIAEENTSCI

G E

O G

R A

PH

I AE PENE T

R A

M U

S

A I

R

N A T I O N A L

G

U A

R D

C I

V

I L

E N G I N E E R

I N

G

FJRP

159062

145TH AIRLIFT WING

NORTH CAROLINA AIR NATIONAL GUARD

CHARLOTTE-DOUGLAS IAP, NORTH CAROLINA

SCALE

DESIGNED BY

REVIEWED BY

DATE

AE PROJ. NO.

DRAWN BY

SHEET

PROJECT NO.

NCANG CIVIL ENGINEERING

REVISIONS

INITIALDESCRIPTIONDATEREV

CHARLOTTE-DOUGLAS IAP CHARLOTTE, NORTH CAROLINA

F6W71900

C-17 FLIGHT SIMULATOR TRAINING FACILITY

54321

D C

B A

08/17/2018

/8

/2

:1

:1

P

M B

IM

/U

S

N o rt h C a ro lin a A ir N a ti o n a l G u a rd /N

C A

N G

C

F lig h t S im u la to r

P L

U M

B

V

.r v t

P-906

J. STAMPER

N. MITCHELL

N. MITCHELL

PLUMBING

C-17 FLIGHT SIMULATOR

DOMESTIC WATER AND GAS PIPING RISER DIAGRAM

A1

C-17 FLIGHT SIMULATOR DOMESTIC WATER

AND GAS PIPING RISER DIAGRAM

L-1

L-1

SK-1

MS-1

L-1

L-1

W-1A

W-1A

EWC-1

W-1A

U-1

HB-1

HYD-1

HYD-1

HYD-1

HYD-1

WHA-1

WHA-1

WHA-1

FIRE SPRINKLER GENERAL NOTES

A. PROVIDE COMPLETE WET PIPE FIRE SPRINKLER SYSTEMS THROUGHOUT THE SIMULATOR BUILDING. PERFORM ALL DESIGN AND INSTALLATION IN ACCORDANCE WITH UFC 3-600-01 (AUGUST 2016 WITH CHANGE 1, NOVEMBER 2016), NFPA 13 (2016), AND SPECIFICATION SECTION 211313.

WET PIPE SPRINKLER SYSTEM RISER

INSPECTOR'S TEST CONNECTION/AUXILIARY DRAIN

FIRE SUPPRESSION GENERAL NOTES AND SYMBOLS

FIRE SPRINKLER/ STANDPIPE SYMBOLS MISCELLANEOUS

REFER TO

RE:2/F-4.0

DRAWING REFERENCE KEY

NOTE BY SYMBOL REFERENCE

CALCULATION NODE POINT (1 NODE)

CALCULATION NODE POINT (2 NODES)

(ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS)

SHEET NUMBER ON WHICH

CONDITION IS SHOWN

SHEET NUMBER ON WHICH

DETAIL IS DRAWN

DRAWING/DETAIL NUMBER 2

F-0.1 F-4.0

POST INDICATOR VALVE WITH PADLOCK

WATERFLOW TEST DATA

CHECK VALVE

WITH GAUGE COCK

PRESSURE GAUGE

PRESSURE CONTROL VALVE

RELIEF VALVE

TEST PORT

VALVE IN CENTER DROP

BLOWDOWN VALVE

TEE OUTLET DOWN

TEE OUTLET UP

GATE VALVE

STRAINER WITH

UNION

CONCENTRIC REDUCER

ECCENTRIC REDUCER

DIRECTION OF FLOW

DIRECTION OF SLOPE DOWN

VALVE IN RISE

VALVE IN DROP

ELBOW UP

ELBOW DOWN

D.

THE TOTAL CALCULATED WATER DEMAND IS THE SUM OF THE SPRINKLER SYSTEM DEMAND PLUS HOSE STREAM ALLOWANCE REQUIRED PER UFC 3-600-01.

F.

COORDINATE THE LOCATION OF RISERS, DRAINS, TEST CONNECTIONS, AND OTHER SPRINKLER SYSTEM COMPONENTS WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PORTIONS OF THE BUILDING.

G.

WATER FLOW TEST DATA NOTED ON THIS SHEET WAS PROVIDED FOR PRELIMINARY HYDRAULIC ANALYSIS AS THE SOURCE FOR THE SIMULATOR BUILDING. VERIFY THE TOTAL SYSTEM DEMAND CAN BE SATISFIED BY THE AVAILABLE WATER SUPPLY.

H.

HYDRAULICALLY CALCULATE THE SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13, UFC 3-600-01, AND THE DENSITY AND SPACING REQUIREMENTS LISTED IN THE SPRINKLER DESIGN CRITERIA TABLE. FIELD VERIFY SYSTEM DESIGN AND LAYOUT PRIOR TO FABRICATION OR INSTALLATION.

I.

INSTALL PIPE HANGERS AND SEISMIC BRACING ON ALL NEW FIRE SPRINKLER PIPING PER NFPA 13 AS REQUIRED BY UFC 3-600-01.

J.

K.

SEE ARCHITECTURAL DRAWINGS FOR ROOM FINISH SCHEDULE, AND ROOM USE. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR THE

LOCATION OF ALL CEILING-MOUNTED DEVICES.

L.

PROVIDE SLEEVES AND WALL PLATES FOR ALL NEW PENETRATIONS THROUGH WALLS OR FLOORS THAT MIGHT INCLUDE DRILLING THROUGH CONCRETE, METAL, SHEETROCK, OR OTHER MATERIALS. FIELD VERIFY APPROXIMATE WALL AND FLOOR PENETRATIONS SHOWN ON THE PLANS.

SEAL ALL PENETRATIONS IN RATED SEPARATIONS TO MEET THE MINIMUM FIRE RATING OF THE WALL OR FLOOR.

M.

PROVIDE ACCESS DOORS AND SIGNAGE WHERE ACCESS IS REQUIRED TO CONCEALED SPRINKLER EQUIPMENT, VALVES, AND CONTROLS LOCATED

IN WALLS OR ABOVE CEILINGS.

PROVIDE THREADED OR WELDED SCHEDULE 40 BLACK STEEL FOR 2-INCH AND SMALLER PIPE, AND WELDED, OR ROLL-GROOVED SCHEDULE 10

BLACK STEEL FOR 2 1/2-INCH AND LARGER PIPE.

THESE DOCUMENTS DEPICT PERFORMANCE LEVEL ENGINEERING DESIGN CRITERIA TO BE UTILIZED AS GUIDANCE FOR THE PLANNING OF THE FIRE SPRINKLER SYSTEMS BY THE CONTRACTOR. PROVIDE COMPLETE DOCUMENTS FOR REVIEW AND APPROVAL FROM THE ENGINEER AND THE AUTHORITY HAVING JURISDICTION PRIOR TO INSTALLATION. INCLUDE IN THE SHOP DRAWINGS AND CALCULATIONS ANY ADDITIONAL EQUIPMENT NECESSARY TO

PROVIDE A COMPLETE INSTALLATION AND COMPLY WITH OWNER STANDARDS.

E.

B.

C.

THE ENGINEER'S CALCULATIONS WERE DEVELOPED TO DETERMINE THE ADEQUACY OF THE FIRE WATER SUPPLY. ANY PIPING ARRANGEMENT AND SIZES INDICATED ON THE PLANS PROVIDE GENERAL INTENT. PROVIDE COMPLETE FIRE SPRINKLER SYSTEM CALCULATIONS WITH SHOP DRAWINGS.

4" X 2-1/2" X 2-1/2" WALL…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.