A-411_-_ENLARGED_PLANS_AND_INTERIOR_ELEVATIONS_SIM_BLDG_Amendment_003.pdf

PDF 420 KB Posted

Attached to
Construct C-17 Simulator Facility Federal contract opportunity
Solicitation number
W91242-19-B-5002
Issued by
Department of the Army North Carolina Army National Guard

About this file

A-411

View the file

Other files for this federal contract opportunity

Other files attached to Construct C-17 Simulator Facility, newest first.
File Type Posted
Bid_Opening_Sign_in_sheet.pdf PDF
OF_1419_-_Bid_Opening_Abstract.pdf PDF
A-504_-_EXTERIOR_WALL_SECTIONS_SIM_BLDG_Amendment_003.pdf PDF
A-505_-_EXTERIOR_WALL_SECTIONS_SIM_BLDG-Amendment_003.pdf PDF
S-505_-_STRUCTURAL_TYPICAL_DETAILS_SIM_BLDG_Amendment_003.pdf PDF
W91242-19-B-5002-0003.pdf PDF
Q&A__3.pdf PDF
CG-101_-_SITE_GRADING_&_DRAINAGE_PLAN_SIM_BLDG_Amendment_003.pdf PDF
M-111-_HVAC_PLANS_SIM_BLDG_Amendment_003.pdf PDF
A-606_-_WINDOW_AND_STRUCTURED_POLYCARBONATE_WALL_PANEL_TYPES_SIM_BLDG_Amendment_003.pdf PDF
A-705_-_STOREFRONT_AND_CURTAINWALL_DETAILS_SIM_BLDG_Amendment_003.pdf PDF
A-511_-_EXTERIOR_WALL_DETAILS_SIM_BLDG_Amendment_003.pdf PDF
08_04_00_-_Blast_Resistance_SIM_BLDG_Amendment_002.pdf PDF
Q&A__2.pdf PDF
CS-101_-_SITE_LAYOUT_PLAN_SIM_BLDG_Amendment_002.pdf PDF
08_45_13_-_Structured-Polycarbonate-Panel_Assemblies_SIM_BLDG_Amendment_002.pdf PDF
W91242-19-B-5002-0002.pdf PDF
S-001_-_STRUCTURAL_GENERAL_NOTES_SIM_BLDG_Amendment_002.pdf PDF
A-601_-_Amendment_0001.pdf PDF
C-502_-_Amendment_0001.pdf PDF
Q&A__1,_29_April_2019.pdf PDF
W91242-19-B-5002-0001.pdf PDF
PreBidSlides_W91242-19-B-5002.ppt PPT presentation
Pre-Bid_Sign-in_Sheet.pdf PDF
Solicitation_Attachment_11_-_Q&A_Simulator_Building_-_Previous_Solicitation.pdf PDF
Solicitation_Attachment_10_-_Visitor_Request_Worksheet.pdf PDF
Solicitation_Attachment_4_-_NCANG_C-17_SIM_B-3_DRAWINGS_Vol2of3_-_Final.pdf PDF
W91242-19-B-5002.pdf PDF
Solicitation_Attachment_8_-_Brand_Name_Justification_MONACO_Redacted.pdf PDF
Solicitation_Attachment_3_-_NCANG_C-17_SIM_B-3_DRAWINGS_Vol1of3_-_Final.pdf PDF
Solicitation_Attachment_9_-_Pre-Bid_Conference_and_Site_Visit,_Bid_Drop-Off_Map1.pdf PDF
Solicitation_Attachment_2_-_NCANG_C-17_SIM_B-3_SPECS_Vol_2of2_17-Aug-2018_-_Final.pdf PDF
Solicitation_Attachment_6_-_NCANG_C-17_SIM_B-3_SUPPLEMENTAL_INFO_17-Aug-2018.pdf PDF
Solicitation_Attachment_12_-_SOW_C-17_Sim_Facility.pdf PDF
Solicitation_Attachment_7_-_Brand_Name_Justification_ALERTON_Redacted.pdf PDF
Solicitation_Attachment_1_-_NCANG_C-17_SIM_B-3_SPECS_Vol_1of2_17-Aug-2018_-_Final.pdf PDF
Solicitation_Attachment_5_-_NCANG_C-17_SIM_B-3_DRAWINGS_Vol3of3_-_Final.pdf PDF
Show all 37

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VS

VS

ENLARGED FLOOR PLAN AND INTERIOR ELEVATION KEYED NOTESTOILET ACCESSORIES SCHEDULE

ITEM ACCESSORY DESCRIPTION MANUFACTURER PRODUCT NO.

MOUNTING

HEIGHT AFF

ELECTRIC

POWER (Y / N) REMARKS

FOLDING SHOWER SEAT BOBRICK B-5181 18" (TOP) NFSS

GRAB BAR - 42" BOBRICK B-5086-42 34" (CTRLINE) NGB-1

GRAB BAR - 36" BOBRICK B-5086-36 NGB-2

SOAP DISH BOBRICK B-4390 NRSD

MIRROR BOBRICK B-165 2436 NMR

PAPER TOWEL DISPENSER GFCI -- 54" (TOP) NPTD

SHOWER CURTAIN BOBRICK B-204-2 SEE SCR NSC

SHOWER CURTAIN ROD BOBRICK B-207 78" (TOP) NSCR

TOILET TISSUE DISPENSER GFCI -- 28" (TOP) NTTD

NWASTE RECEPTACLE GFCI -- 42" - 46" (TOP)

N

WR

UTILITY SHELF BOBRICK B-223 36 72" (TOP)US

ROBE HOOK BOBRICK B-672 40" (TOP) NRH

34" (CTRLINE)

MIRROR - FULL LENGTH BOBRICK B-165 2460 NMR2

40" (BOTTOM)

24" (BOTTOM)

42" (BOTTOM)

ABA

GRAB BAR - 18" BOBRICK B-5086-18 42" (CTRLINE) NGB-3

GRAB BAR - SHOWER BOBRICK B-5837 NGB-4 34" (CTRLINE)

VERTICAL

B4 / A-572

FINISH FLOOR

EL: 100' - 0"

A3

A-572

B3

A-572

A2

A-572

3' - 2" 3' - 6"

PT-2PT-2PT-5 PT-2

1' - 9" 1' - 9" 3' - 0" 1' - 9" 1' - 9"

RECYCLING

(GFGI)

MEN

S110

WOMEN

S108

JANITOR

S109

S108

S109

S110

A-411

B4

B3

A-411

C4

C3

0E

0E 0E

0E

0D

0E

0E

0E

5' - 0" 9' - 3 1/2"

8'

1/

4" 9'

8"

2' - 6" 1' - 10"

C

LE

A R

5'

0" T

Y P

IC

A

L

0"

1'

6"

/4

4'

0" 4'

0"

0E

0E

0E

2'

(PTD)

(WR)

(PTD)

(WR)

(US)

FINISH FLOOR

EL: 100' - 0"

CWT-1

CWT-2

CWB-1

(MR)

2' - 0"1' - 10"2' - 2"

PT-1

3'

4"

8 3

(PTD)

1' - 10"2' - 6"

(WR)

FINISH FLOOR

EL: 100' - 0"

CWT-1

CWT-2

CWB-1

(GB-2)

(GB-1)

3'

4"

PT-7

PT-1

3' - 6" 3' - 0 5/8"

CLEAR, TYPICAL

5' - 0"

TYP, CLR

3' - 0"

TTD-1

NOTE: PROVIDE FULL HEIGHT CERAMIC WALL

TILE AT PARTITIONS WITH TOILETS AND URINALS.

THE REMAINING PARTITIONS IN THE RESTROOM

TO RECEIVE CERAMIC WALL TILE WAINSCOT.

FINISH FLOOR

EL: 100' - 0"

CWT-1

CWT-2

CWB-1

(GB-2)

(GB-1)

PT-7

3'

4"

PT-1

3' - 1" 3' - 6"

TYPICAL, CLEAR

5' - 0"

TYP, CLR

3' - 0"

(TTD)

NOTE: PROVIDE FULL HEIGHT CERAMIC WALL

TILE AT PARTITIONS WITH TOILETS. THE

REMAINING PARTITIONS IN THE RESTROOM

TO RECEIVE CERAMIC WALL TILE WAINSCOT.

FINISH FLOOR

EL: 100' - 0"

CWT-1

CWT-2

CWB-1

(MR)

2' - 2"1' - 10"2' - 0"

PT-1

3'

4"

(PTD)

(WR)

2' - 6"1' - 10"

S4 S3

SF

SE

WEAPON SYSTEM COMPUTER ROOM

S124

D1

A-411

D1

A-411 D3

A-411

D1

A-411

0G

0G

0H

S

START POINT

1' - 0"

6"

0H

1' - 6 1/2" 4' - 0 1/2"

EQ EQ

2'

2'

1/

2"

1' - 6" 4' - 0 1/2"

8" 2'

EQ EQ

2' - 6"

3'

1/

2"

2'

1/

2"

GAPS NOT TO EXCEED MARGIN

SET BY WIDTH OF WALL BASE

OR THRESHOLD MOLDING (TYP.)

STRINGER WITH COATING

RAISED ACCESS FLOOR PANEL -

FULL SIZE OR CUT AGAINST WALL.

USE WOOD SHIM IF NECESSARY

TO ARREST SHIFTING.

PERIMETER PEDESTAL

ASSEMBLY

CONCRETE SLAB, REFER TO

STRUCTURAL DRAWINGS

PERIMETER WALL

CONTINUOUS ACOUSTICAL SEALANT

PERIMETER HEAD ASSEMBLY

24" STRINGER CUT BACK ON

SITE TO SUIT PERIMETER DIMENSIONS

PEDESTAL ASSEMBLY, REFER

TO DETAIL THIS DRAWING

RAISED ACCESS FLOOR PANEL

FIELD CUT

CONCRETE SLAB, REFER TO

STRUCTURAL DRAWINGS

CONTINUOUS ACOUSTICAL SEALANT

GAPS NOT TO EXCEED MARGIN

SET BY WIDTH OF WALL BASE

OR THRESHOLD MOLDING (TYP.)

FLOOR FINISH, REFER TO

ROOM FINISH SCHEDULE

PERIMETER WALL

MAX

4"

6"

6" 6"

5” (NOMINAL) GROMMETS WITH COVERS

RAISED ACCESS FLOORING PANEL

NOTE:

GROMMETS SHALL BE ROTARY LID WITH

INTEGRAL FOAM INSERTS

COORDINATE CUT-OUT PANEL

LOCATION WITH TELECOMM,

ELECTRICAL AND MECHANICAL

EQUIPMENT

1.

2.

REFLECTED CEILING PLAN LEGEND

GYPSUM BOARD CEILING

APC-1

SUPPLY AIR DIFFUSER

RETURN AIR DIFFUSER

LINEAR SUPPLY AIR DIFFUSER

LINEAR RETURN AIR DIFFUSER

EXHAUST AIR GRILL

EXHAUST FAN

EXIT SIGN (DARKENED AREA DENOTES LIGHTED FACE, TRIANGLES INDICATE

EMERGENCY LIGHTS)

OCCUPANCY SENSOR, CEILING MOUNTED, MULTI DIRECTIONAL

LIGHTING FIXTURES,

REFER TO ELECTRICAL

ACCESS PANEL

FIRE SUPPRESSION -

SIDEWALL SPRINKLER

FIRE ALARM - CEILING SPEAKER

VS

OCCUPANCY SENSOR, CEILING MOUNTEDOS OS

PHOTOCELL SENSOR, CEILING MOUNTEDPC

5'

0" M

IN

IM

U M

(C

LE

A R

(G B

-2

3'

0" M

IN

1'

6"

C

LE

A R

6" M

A X

3" M

A X

3' - 6" MIN (CLEAR)

2'

0" M

IN

2'

8"

M

IN

2'-0" MIN

GRAB BAR

3' - 4" TO VERTICAL

(GB-1)

3' - 6" MINIMUM1' - 0" MAX

4' - 4" MINIMUM

56" MINIMUM (WALL HUNG)

59" MINIMUM (FLOOR MOUNTED)

TISSUE DISPENSER

2' - 10" TO TOILET

(TTD)

(GB-3)

IAINNFCOQUEIAEENTSCI

G E

O G

R A

PH

I AE PENE T

R A

M U

S

A I

R

N A T I O N A L

G

U A

R D

C I

V

I L

E N G I N E E R

I N

G

FJRP

159062

145TH AIRLIFT WING

NORTH CAROLINA AIR NATIONAL GUARD

CHARLOTTE-DOUGLAS IAP, NORTH CAROLINA

SCALE

DESIGNED BY

REVIEWED BY

DATE

AE PROJ. NO.

DRAWN BY

SHEET

PROJECT NO.

NCANG CIVIL ENGINEERING

REVISIONS

INITIALDESCRIPTIONDATEREV

CHARLOTTE-DOUGLAS IAP CHARLOTTE, NORTH CAROLINA

F6W71900

C-17 FLIGHT SIMULATOR TRAINING FACILITY

54321

D C

B A

08/17/2018As indicated

/7

/2

:0

:4

P

M B

IM

/U

S

N o rt h C a ro lin a

A ir N a ti o n a l G u a rd

/N C

A N

G

C

F lig h t S im u la to r

A

R C

H

V

.r v t

A-411

D. FLIPPEN

N. FREY

B. DYSON

ARCHITECTURAL

C-17 FLIGHT SIMULATOR

ENLARGED PLANS AND INTERIOR ELEVATIONS

1/4" = 1'-0"

2' 4' 8' 12'

1 MOP SINK WITH PLASTIC PANELING - REFER TO A3 / A-573

2 FLOOR DRAIN / CLEANOUT. FLOOR SLOPES TO DRAIN - REFER TO PLUMBING

3 WALL MOUNTED SINK WITH INTEGRAL APRON, REFER TO PLUMBING

4 REFRIGERATOR (GFGI)

5 TOILET PARTITION - TP-1

6 BASE AS SCHEDULED

7 FIRE ALARM EQUIPMENT - REFER TO FIRE ALARM DRAWINGS

8 GFCI RECEPTACLE - REFER TO ELECTRICAL.

9 CONTROL JOINT - REFER TO B4 / A-571

10 ACCESSIBLE TOILET STALL - REFER TO A4 / A-411

11 ACCESS PANEL - REFER TO B3 / A-571

1/4" = 1'-0"

A-111

B1

INTERIOR ELEVATION - ADMIN / INSTRUCTORS S104

1/4" = 1'-0"

A-111

A2

ENLARGED FLOOR PLAN

1/4" = 1'-0"

A-411

B4

INTERIOR ELEVATION - MEN S110

1/4" = 1'-0"

A-411

B3

INTERIOR ELEVATION - MEN S110

1/4" = 1'-0"

A-411

C3

INTERIOR ELEVATION - WOMEN S108

1/4" = 1'-0"

A-411

C4

INTERIOR ELEVATION - WOMEN S108

1/4" = 1'-0"

A-111

A1

ENLARGED FLOOR PLAN - RAISED ACCESS FLOOR

N

N

1/4" = 1'-0"

A-131

A3

ENLARGED REFLECTED CEILING PLAN

N

NOT TO SCALE

A-411

D3

RAISED ACCESS FLOORING AT PERIMETER

NOT TO SCALE

A-411

D1

RAF AT PERIMETER CANTILEVER

NOT TO SCALEC1

PANEL GROMMET CUT-OUT

A-411

1/2" = 1'-0"A4

ACCESSIBLE TOILET STALL

1 05/06/2019 AMENDMENT 003 BJD

Sheets
A-411 - C-17 FLIGHT SIMULATOR ENLARGED PLANS AND INTERIOR ELEVATIONS
A-504 - C-17 FLIGHT SIMULATOR EXTERIOR WALL SECTIONS
A-505 - C-17 FLIGHT SIMULATOR EXTERIOR WALL SECTIONS
A-511 - EXTERIOR WALL DETAILS
A-606 - WINDOW AND STRUCTURED POLYCARBONATE WALL PANEL TYPES
A-705 - STOREFRONT AND CURTAINWALL DETAILS

File details come from the government source that posted it.