Text version
VS
VS
ENLARGED FLOOR PLAN AND INTERIOR ELEVATION KEYED NOTESTOILET ACCESSORIES SCHEDULE
ITEM ACCESSORY DESCRIPTION MANUFACTURER PRODUCT NO.
MOUNTING
HEIGHT AFF
ELECTRIC
POWER (Y / N) REMARKS
FOLDING SHOWER SEAT BOBRICK B-5181 18" (TOP) NFSS
GRAB BAR - 42" BOBRICK B-5086-42 34" (CTRLINE) NGB-1
GRAB BAR - 36" BOBRICK B-5086-36 NGB-2
SOAP DISH BOBRICK B-4390 NRSD
MIRROR BOBRICK B-165 2436 NMR
PAPER TOWEL DISPENSER GFCI -- 54" (TOP) NPTD
SHOWER CURTAIN BOBRICK B-204-2 SEE SCR NSC
SHOWER CURTAIN ROD BOBRICK B-207 78" (TOP) NSCR
TOILET TISSUE DISPENSER GFCI -- 28" (TOP) NTTD
NWASTE RECEPTACLE GFCI -- 42" - 46" (TOP)
N
WR
UTILITY SHELF BOBRICK B-223 36 72" (TOP)US
ROBE HOOK BOBRICK B-672 40" (TOP) NRH
34" (CTRLINE)
MIRROR - FULL LENGTH BOBRICK B-165 2460 NMR2
40" (BOTTOM)
24" (BOTTOM)
42" (BOTTOM)
ABA
GRAB BAR - 18" BOBRICK B-5086-18 42" (CTRLINE) NGB-3
GRAB BAR - SHOWER BOBRICK B-5837 NGB-4 34" (CTRLINE)
VERTICAL
B4 / A-572
FINISH FLOOR
EL: 100' - 0"
A3
A-572
B3
A-572
A2
A-572
3' - 2" 3' - 6"
PT-2PT-2PT-5 PT-2
1' - 9" 1' - 9" 3' - 0" 1' - 9" 1' - 9"
RECYCLING
(GFGI)
MEN
S110
WOMEN
S108
JANITOR
S109
S108
S109
S110
A-411
B4
B3
A-411
C4
C3
0E
0E 0E
0E
0D
0E
0E
0E
5' - 0" 9' - 3 1/2"
8'
1/
4" 9'
8"
2' - 6" 1' - 10"
C
LE
A R
5'
0" T
Y P
IC
A
L
0"
1'
6"
/4
4'
0" 4'
0"
0E
0E
0E
2'
(PTD)
(WR)
(PTD)
(WR)
(US)
FINISH FLOOR
EL: 100' - 0"
CWT-1
CWT-2
CWB-1
(MR)
2' - 0"1' - 10"2' - 2"
PT-1
3'
4"
8 3
(PTD)
1' - 10"2' - 6"
(WR)
FINISH FLOOR
EL: 100' - 0"
CWT-1
CWT-2
CWB-1
(GB-2)
(GB-1)
3'
4"
PT-7
PT-1
3' - 6" 3' - 0 5/8"
CLEAR, TYPICAL
5' - 0"
TYP, CLR
3' - 0"
TTD-1
NOTE: PROVIDE FULL HEIGHT CERAMIC WALL
TILE AT PARTITIONS WITH TOILETS AND URINALS.
THE REMAINING PARTITIONS IN THE RESTROOM
TO RECEIVE CERAMIC WALL TILE WAINSCOT.
FINISH FLOOR
EL: 100' - 0"
CWT-1
CWT-2
CWB-1
(GB-2)
(GB-1)
PT-7
3'
4"
PT-1
3' - 1" 3' - 6"
TYPICAL, CLEAR
5' - 0"
TYP, CLR
3' - 0"
(TTD)
NOTE: PROVIDE FULL HEIGHT CERAMIC WALL
TILE AT PARTITIONS WITH TOILETS. THE
REMAINING PARTITIONS IN THE RESTROOM
TO RECEIVE CERAMIC WALL TILE WAINSCOT.
FINISH FLOOR
EL: 100' - 0"
CWT-1
CWT-2
CWB-1
(MR)
2' - 2"1' - 10"2' - 0"
PT-1
3'
4"
(PTD)
(WR)
2' - 6"1' - 10"
S4 S3
SF
SE
WEAPON SYSTEM COMPUTER ROOM
S124
D1
A-411
D1
A-411 D3
A-411
D1
A-411
0G
0G
0H
S
START POINT
1' - 0"
6"
0H
1' - 6 1/2" 4' - 0 1/2"
EQ EQ
2'
2'
1/
2"
1' - 6" 4' - 0 1/2"
8" 2'
EQ EQ
2' - 6"
3'
1/
2"
2'
1/
2"
GAPS NOT TO EXCEED MARGIN
SET BY WIDTH OF WALL BASE
OR THRESHOLD MOLDING (TYP.)
STRINGER WITH COATING
RAISED ACCESS FLOOR PANEL -
FULL SIZE OR CUT AGAINST WALL.
USE WOOD SHIM IF NECESSARY
TO ARREST SHIFTING.
PERIMETER PEDESTAL
ASSEMBLY
CONCRETE SLAB, REFER TO
STRUCTURAL DRAWINGS
PERIMETER WALL
CONTINUOUS ACOUSTICAL SEALANT
PERIMETER HEAD ASSEMBLY
24" STRINGER CUT BACK ON
SITE TO SUIT PERIMETER DIMENSIONS
PEDESTAL ASSEMBLY, REFER
TO DETAIL THIS DRAWING
RAISED ACCESS FLOOR PANEL
FIELD CUT
CONCRETE SLAB, REFER TO
STRUCTURAL DRAWINGS
CONTINUOUS ACOUSTICAL SEALANT
GAPS NOT TO EXCEED MARGIN
SET BY WIDTH OF WALL BASE
OR THRESHOLD MOLDING (TYP.)
FLOOR FINISH, REFER TO
ROOM FINISH SCHEDULE
PERIMETER WALL
MAX
4"
6"
6" 6"
5” (NOMINAL) GROMMETS WITH COVERS
RAISED ACCESS FLOORING PANEL
NOTE:
GROMMETS SHALL BE ROTARY LID WITH
INTEGRAL FOAM INSERTS
COORDINATE CUT-OUT PANEL
LOCATION WITH TELECOMM,
ELECTRICAL AND MECHANICAL
EQUIPMENT
1.
2.
REFLECTED CEILING PLAN LEGEND
GYPSUM BOARD CEILING
APC-1
SUPPLY AIR DIFFUSER
RETURN AIR DIFFUSER
LINEAR SUPPLY AIR DIFFUSER
LINEAR RETURN AIR DIFFUSER
EXHAUST AIR GRILL
EXHAUST FAN
EXIT SIGN (DARKENED AREA DENOTES LIGHTED FACE, TRIANGLES INDICATE
EMERGENCY LIGHTS)
OCCUPANCY SENSOR, CEILING MOUNTED, MULTI DIRECTIONAL
LIGHTING FIXTURES,
REFER TO ELECTRICAL
ACCESS PANEL
FIRE SUPPRESSION -
SIDEWALL SPRINKLER
FIRE ALARM - CEILING SPEAKER
VS
OCCUPANCY SENSOR, CEILING MOUNTEDOS OS
PHOTOCELL SENSOR, CEILING MOUNTEDPC
5'
0" M
IN
IM
U M
(C
LE
A R
(G B
-2
3'
0" M
IN
1'
6"
C
LE
A R
6" M
A X
3" M
A X
3' - 6" MIN (CLEAR)
2'
0" M
IN
2'
8"
M
IN
2'-0" MIN
GRAB BAR
3' - 4" TO VERTICAL
(GB-1)
3' - 6" MINIMUM1' - 0" MAX
4' - 4" MINIMUM
56" MINIMUM (WALL HUNG)
59" MINIMUM (FLOOR MOUNTED)
TISSUE DISPENSER
2' - 10" TO TOILET
(TTD)
(GB-3)
IAINNFCOQUEIAEENTSCI
G E
O G
R A
PH
I AE PENE T
R A
M U
S
A I
R
N A T I O N A L
G
U A
R D
C I
V
I L
E N G I N E E R
I N
G
FJRP
159062
145TH AIRLIFT WING
NORTH CAROLINA AIR NATIONAL GUARD
CHARLOTTE-DOUGLAS IAP, NORTH CAROLINA
SCALE
DESIGNED BY
REVIEWED BY
DATE
AE PROJ. NO.
DRAWN BY
SHEET
PROJECT NO.
NCANG CIVIL ENGINEERING
REVISIONS
INITIALDESCRIPTIONDATEREV
CHARLOTTE-DOUGLAS IAP CHARLOTTE, NORTH CAROLINA
F6W71900
C-17 FLIGHT SIMULATOR TRAINING FACILITY
54321
D C
B A
08/17/2018As indicated
/7
/2
:0
:4
P
M B
IM
/U
S
N o rt h C a ro lin a
A ir N a ti o n a l G u a rd
/N C
A N
G
C
F lig h t S im u la to r
A
R C
H
V
.r v t
A-411
D. FLIPPEN
N. FREY
B. DYSON
ARCHITECTURAL
C-17 FLIGHT SIMULATOR
ENLARGED PLANS AND INTERIOR ELEVATIONS
1/4" = 1'-0"
2' 4' 8' 12'
1 MOP SINK WITH PLASTIC PANELING - REFER TO A3 / A-573
2 FLOOR DRAIN / CLEANOUT. FLOOR SLOPES TO DRAIN - REFER TO PLUMBING
3 WALL MOUNTED SINK WITH INTEGRAL APRON, REFER TO PLUMBING
4 REFRIGERATOR (GFGI)
5 TOILET PARTITION - TP-1
6 BASE AS SCHEDULED
7 FIRE ALARM EQUIPMENT - REFER TO FIRE ALARM DRAWINGS
8 GFCI RECEPTACLE - REFER TO ELECTRICAL.
9 CONTROL JOINT - REFER TO B4 / A-571
10 ACCESSIBLE TOILET STALL - REFER TO A4 / A-411
11 ACCESS PANEL - REFER TO B3 / A-571
1/4" = 1'-0"
A-111
B1
INTERIOR ELEVATION - ADMIN / INSTRUCTORS S104
1/4" = 1'-0"
A-111
A2
ENLARGED FLOOR PLAN
1/4" = 1'-0"
A-411
B4
INTERIOR ELEVATION - MEN S110
1/4" = 1'-0"
A-411
B3
INTERIOR ELEVATION - MEN S110
1/4" = 1'-0"
A-411
C3
INTERIOR ELEVATION - WOMEN S108
1/4" = 1'-0"
A-411
C4
INTERIOR ELEVATION - WOMEN S108
1/4" = 1'-0"
A-111
A1
ENLARGED FLOOR PLAN - RAISED ACCESS FLOOR
N
N
1/4" = 1'-0"
A-131
A3
ENLARGED REFLECTED CEILING PLAN
N
NOT TO SCALE
A-411
D3
RAISED ACCESS FLOORING AT PERIMETER
NOT TO SCALE
A-411
D1
RAF AT PERIMETER CANTILEVER
NOT TO SCALEC1
PANEL GROMMET CUT-OUT
A-411
1/2" = 1'-0"A4
ACCESSIBLE TOILET STALL
1 05/06/2019 AMENDMENT 003 BJD
| Sheets |
| A-411 - C-17 FLIGHT SIMULATOR ENLARGED PLANS AND INTERIOR ELEVATIONS |
| A-504 - C-17 FLIGHT SIMULATOR EXTERIOR WALL SECTIONS |
| A-505 - C-17 FLIGHT SIMULATOR EXTERIOR WALL SECTIONS |
| A-511 - EXTERIOR WALL DETAILS |
| A-606 - WINDOW AND STRUCTURED POLYCARBONATE WALL PANEL TYPES |
| A-705 - STOREFRONT AND CURTAINWALL DETAILS |
File details come from the government source that posted it.