FINISH FLOOR
EL: 100' - 0"
SPLIT FACE CMU
VENEER
AIR CAVITY
2 1/2" RIGID INSULATION
8" (NOM.) CMU
FLUID APPLIED
AIR BARRIERCAVITY DRAINAGE
MATERIAL
WEEP VENTS AT 24" O.C.
FLASHING WITH CONTINUOUS
SEALANT AT DRIP EDGE
FINISHED GRADE,
REFER TO CIVIL
CONCRETE FOUNDATION AND
SLAB, REFER TO STRUCTURAL
2" PERIMETER INSULATION
- EXTEND 2' FROM EDGE
COMPRESSED
GRAVEL INFILL
GROUT SOLID, CANT
TOP OF GROUT FOR
PROPER DRAINAGE
1/2"
BRICK VENEER - REFER
TO ELEVATIONS FOR
LOCATIONS
VAPOR RETARDER
GROUND FACE
CMU VENEER
DAMPROOFING
STANDING SEAM
METAL ROOF SYSTEM
1/2" COVER BOARD
FLASHING WITH
DRIP EDGE
GUTTER STRAP
PREFINISHED METAL
GUTTER
BENT PLATE, REFER
TO STRUCTURAL
RIGID INSULATION
FLUID APPLIED
AIR BARRIER
8" (NOM.) CMU
METAL DECK, REFER
TO STRUCTURAL
S1
CONTINUOUS
UNDERLAYMENT
4 1/2" RIGID
INSULATION (R-25 MIN)
TREATED WOOD
BLOCKING
STEEL TRUSS WITH
BENT PLATE
CONNECTION, REFER
TO STRUCTURAL
FOAMED IN-PLACE
INSULATION
CONTINUOUS
SEALANT AT
FLASHING DRIP EDGE
8" (NOM.) CMU
STEEL COLUMN,
REFER TO
STRUCTURAL
FLUID APPLIED
AIR BARRIER
BRICK VENEER
2 1/2" RIGID
INSULATION
CONTINUOUS SEALANT
AT FLASHING DRIP EDGE
STANDING SEAM
METAL ROOF SYSTEM
RIGID INSULATION
METAL DECK, REFER
TO STRUCTURAL
S2
1' - 3 1/2"8"
8" M
IN
TREATED WOOD
BLOCKING
CELLULAR WEEPS AT 24" O.C.
COUNTER-FLASHING
BENT METAL ROOFING
TRIM BY STANDING SEAM
ROOF MANUFACTURER
STEEL BENT PLATE -
REFER TO STRUCTURAL
STANDING SEAM METAL
ROOFING SYSTEM
1/2" COVERBOARD
4 1/2" RIGID INSULATION
(R-25 MIN)
METAL DECK -
REFER TO
STRUCTURAL
INSULATED METAL
WALL PANEL (MWP-1)
CONTINUOUS
UNDERLAYMENT - WRAP
OVER TOP OF METAL PANEL
S2
1' - 8"
STEEL TRUSS WITH
BENT PLATE
CONNECTION
TREATED BLOCKING
CONTINUOUS SEALANT AT
FLASHING DRIP EDGE
CONTINUOUS
CLEAT AT
FLASHING
8" (NOM.) CMU
METAL COPING
WITH CONTINUOUS
CLEATS BOTH SIDES
FLUID APPLIED
AIR BARRIER
BRICK VENEER
2 1/2" RIGID
INSULATION
AIR CAVITY
1' - 3 1/2"
SLOPE
FLEX FLASHING
OVER WOOD
BLOCKING
CONTINUOUS SEALANT
AT FLASHING DRIP
EDGE, BOTH SIDES
8"6"
MECH MEZZANINE
EL: 114' - 0"
8" (NOM.) CMU
CONCRETE SLAB,
REFER TO STRUCTURAL
STEEL GIRDER, REFER
TO STRUCTURAL
S2 2"1' - 3 5/8"
GROUND FACE CMU VENEER
BRICK VENEER, REFER
TO ELEVATIONS
BRICK VENEER, REFER
TO ELEVATIONS
FLUID-APPLIED
VAPOR BARRIER
8" (NOM.) CMU
2 1/2" RIGID
INSULATION
AIR CAVITY
1' - 3 1/2"1/2"
5/8" GYP ON 2 1/2"
METAL STUDS,
WHERE OCCURS
INSULATED METAL
WALL PANEL (MWP-1)
HSS STEEL FRAMING
MEMBER, REFER TO
STRUCTURAL, PAINT
EXPOSED AREAS
POLYCARBONATE
PANEL STOREFRONT
SYSTEM, REFER TO
A-607
UTILITY BRICK
VENEER, BEYOND
SA
METAL PANEL TRIM
WITH DRIP EDGE
10"
10"1/2" 5 1/2"
CONTINUOUS
SEALANT
FINISH FLOOR
EL: 100' - 0"
SPLIT-FACE CMU
VENEER BEYOND
POLYCARBONATE PANEL
STOREFRONT SYSTEM,
REFER TO A-607
CONCRETE SLAB AND
FOUNDATION, REFER TO
STRUCTURAL
FINISHED GRADE,
REFER TO CIVIL
COMPRESSED GRAVEL
INFILL
SA
10"
SUBSILL WITH END DAMS
AND FLASHING
2" PERIMETER
INSULATION - EXTEND 2'
FROM OUTSIDE EDGE
VAPOR RETARDER
CONTINUOUS SEALANT
AT DRIP EDGE
STANDING SEAM
METAL ROOFING
1/2" COVERBOARD
METAL DECK,
REFER TO
STRUCTURAL
LADDER WHERE
OCCURS - REFER
TO A1 / A-423
INSULATED
METAL WALL
PANEL (MWP-1)
1' - 7 5/8" 5 1/2"
SE
4 1/2" RIGID
INSULATION
(R-25 MIN)
CONTINUOUS
UNDERLAYMENT
BENT PLATE AS
REQUIRED BY LADDER
MANUFACTURER
CONTINUOUS
SEALANT,
BOTH SIDES
CONTINUOUS
SEALANT AT
FLASHING
DRIP EDGE
BENT METAL
ROOFING TRIM
BY STANDING
SEAM ROOF
MANUFACTURER
CONTINUOUS
CLEAT AT
FLASHING
S2
8 1/2" 1' - 11 1/2" 4"
LADDER WHERE
OCCURS
LADDER MOUNTING
BRACKET BY LADDER
MANUFACTURER
8" (NOM.) CMU
PVC ROOF
MEMBRANE
1/2" COVERBOARD
2 1/2" RIGID
INSULATION
METAL COPING
WITH CONTINUOUS
CLEATS BOTH SIDES
METAL GRATE
LANDING
BRICK VENEER
LADDER MOUNTING
BRACKET BY LADDER
MANUFACTURER
SLOPE
1/2" PLYWOOD CAP
FLUID APPLIED
AIR BARRIER
CONTINUOUS
SEALANT AT
COPING DRIP
EDGE, BOTH SIDES
FLEX FLASHING OVER
WOOD BLOCKING
S2
8 1/2" 1' - 11 1/2"
8" (NOM.) CMU
CONTINUOUS
TERMINAION BAR
AND SEALANT
FLUID APPLIED AIR
BARRIER
CAVITY DRAINAGE
MATERIAL
2 1/2" RIGID
INSULATION
METAL FLASHING
WITH DRIP EDGE
1/2" COVERBOARD
STANDING SEAM
METAL ROOF SYSTEM
LADDER WHERE
OCCURS
LADDER MOUNTING
BRACKET PER
MANUFACTURERS
RECOMMENDATIONS
VENEER LEDGE
ANGLE, REFER TO
STRUCTURAL - PAINT
CELLULAR WEEPS
AT 24" O.C.
SE
1' - 8" 5 1/2"
LADDER WHERE
OCCURS
LADDER MOUNTING
BRACKET, COORDINATE
WITH STEEL FRAMING
STEEL FRAMING, REFER
TO STRUCTURAL
8" (NOM.) CMU
CONTINUOUS SEALANT AT
FLASHING DRIP EDGE
PVC ROOF MEMBRANE
1/2" COVERBOARD
RIGID INSULATION
STEEL ANGLE AS
REQUIRED BY LADDER
MANUFACTURER
TREATED WOOD
BLOCKING
CONTINUOUS CLEAT
CONTINUOUS BACKER
ROD AND SEALANT
CONTINUOUS SEALANT
EXTEND FLASHING
BEHIND INSULATED
METAL WALL PANEL
FOAMED-IN-PLACE
INSULATION
INSULATED METAL
WALL PANEL (MWP-1)
SA
INSULATED METAL
WALL PANEL (MWP-1)
HSS STEEL FRAMING
MEMBER, REFER TO
STRUCTURAL, PAINT
EXPOSED AREAS
8" (NOM.) CMU
UTILITY BRICK
VENEER
METAL PANEL TRIM
WITH DRIP EDGE AND
CONTINUOUS SEALANT
10"
FLUID APPLIED
VAPOR BARRIER
2 1/2" RIGID
INSULATION
1/2" 1' - 3 1/2"
3/
4"
7/ 8"
3 1/4" 4 3/4"
CAST STONE SILL
GALVANIZED L3x3x1/4
WITH 1/2" EXPANSION
ANCHORS AT 16" O.C.
H6
INSULATED METAL
WALL PANEL (MWP-1)
TREATED WOOD
BLOCKING
BENT METAL ROOFING
TRIM BY STANDING SEAM
ROOF MANUFACTURER
BENT PLATE, REFER
TO STRUCTURAL
4 1/2" RIGID
INSULATION
1/2" COVER
BOARD
STANDING SEAM
METAL ROOF
SYSTEM
METAL DECK,
REFER TO
STRUCTURAL
1' - 5"
CONTINUOUS SEALANT
AT FLASHING DRIP EDGE
CONTINUOUS
CLEAT AT
FLASHING
HA
INSULATED METAL
WALL PANEL (MWP-1)
TREATED WOOD
BLOCKING
FLASHING AND
COUNTERFLASHING
4 1/2" RIGID
INSULATION
(R-25 MIN)
1/2" COVER
BOARD
STANDING SEAM
METAL ROOF SYSTEM
METAL DECK,
REFER TO
STRUCTURAL
PREFINISHED METAL
GUTTER
1' - 5"
CONTINUOUS
UNDERLAYMENT -
WRAP OVER TOP
OF METAL PANEL
STEEL TRUSS
WITH BENT
PLATE
CONNECTION,
REFER TO
STRUCTURAL
STEEL ANGLE,
REFER TO
STRUCTURAL
ROOF CLIPS SET IN MASTIC,
PER MANUFACTURER'S
REQ'MTS
FLASHING WITH DRIP
EDGE AND SEALANT
CONTINUOUS CLEAT
AT FLASHING
IAINNFCOQUEIAEENTSCI
G E
O G
R A
PH
I AE PENE T
R A
M U
S
A I
R
N A T I O N A L
G
U A
R D
C I
V
I L
E N G I N E E
R
I N
G
FJRP
159062
145TH AIRLIFT WING
NORTH CAROLINA AIR NATIONAL GUARD
CHARLOTTE-DOUGLAS IAP, NORTH CAROLINA
SCALE
DESIGNED BY
REVIEWED BY
DATE
AE PROJ. NO.
DRAWN BY
SHEET
PROJECT NO.
NCANG CIVIL ENGINEERING
REVISIONS
INITIALDESCRIPTIONDATEREV
CHARLOTTE-DOUGLAS IAP CHARLOTTE, NORTH CAROLINA
F6W71900
C-17 FLIGHT SIMULATOR TRAINING FACILITY
54321
D C
B A
08/17/2018 1 1/2" =
1'-0"
/7
/2
:0
:5
P
M B
IM
/U
S
N o rt h C a ro lin a
A ir N a ti o n a l G u a rd
/N C
A N
G
C
F lig h t S im u la to r
A
R C
H
V
.r v t
A-511
D. FLIPPEN
N. FREY
B. DYSON
ARCHITECTURAL
EXTERIOR WALL
DETAILS
0 2'
1 1/2" = 1'-0"
6" 1'
1 1/2" = 1'-0"A4
SECTION DETAIL
1 1/2" = 1'-0"
A-505
D1
SECTION DETAIL
1 1/2" = 1'-0"
A-504
B1
SECTION DETAIL
1 1/2" = 1'-0"
A-504
D3
SECTION DETAIL
1 1/2" = 1'-0"
A-504
C1
WALL DETAIL
1 1/2" = 1'-0"
A-505
A1
WALL DETAIL
1 1/2" = 1'-0"B5
SECTION DETAIL
1 1/2" = 1'-0"
A-504
B3
SECTION DETAIL
1 1/2" = 1'-0"
A-504
A3
SECTION DETAIL
1 1/2" = 1'-0"
A-423
D2
SECTION DETAIL
1 1/2" = 1'-0"
A-423
B2
SECTION DETAIL
1 1/2" = 1'-0"
A-423
A2
SECTION DETAIL
1 1/2" = 1'-0"
A-423
C2
SECTION DETAIL
1 1/2" = 1'-0"
A-504
C3
SECTION DETAIL
1 1/2" = 1'-0"D4
SECTION DETAIL
1 1/2" = 1'-0"C4
SECTION DETAIL
A-504
A-504
A-504
A-504
1 05/06/2019 AMENDMENT 003 BJD
| Sheets |
| A-411 - C-17 FLIGHT SIMULATOR ENLARGED PLANS AND INTERIOR ELEVATIONS |
| A-504 - C-17 FLIGHT SIMULATOR EXTERIOR WALL SECTIONS |
| A-505 - C-17 FLIGHT SIMULATOR EXTERIOR WALL SECTIONS |
| A-511 - EXTERIOR WALL DETAILS |
| A-606 - WINDOW AND STRUCTURED POLYCARBONATE WALL PANEL TYPES |
| A-705 - STOREFRONT AND CURTAINWALL DETAILS |
File details come from the government source that posted it.