Attachment 13_08 71 00_revised 25 NOV 2020_Door Hardware.pdf

PDF 57 KB Posted

Attached to
Cyber Operations Facility
Solicitation number
W9123621B2013
Issued by

About this file

This document is a hardware specification for a Cyber Operations Facility project. It provides hardware sets for 15 doors requiring items such as hinges, locks, exit devices, closers, thresholds, and accessories. Key details include the solicitation number W91236-21-B-2013 for an invitation for bid posted by the Department of the Army Corps of Engineers Engineering District Norfolk. The project location is Joint Base Langley-Eustis in Virginia. Hardware is specified for interior and exterior doors, including electrified locks and connections to security systems. Finishes, handings, mounting details and descriptions of door functions are included.

View the file

Other files

Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

185th CYBER OPS FACILITY W91236-17-D-0001

JOINT BASE LANGLEY-EUSTIS, VA

SECTION 08 71 00

DOOR HARDWARE

02/16

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by the basic designation only.

ASTM INTERNATIONAL (ASTM)

ASTM E283 (2004; R 2012) Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen

BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)

ANSI/BHMA A156.1 (2016) Butts and Hinges

ANSI/BHMA A156.10 (2011) Power Operated Pedestrian Doors

ANSI/BHMA A156.13 (2017) Mortise Locks & Latches Series 1000

ANSI/BHMA A156.15 (2015) Release Devices Closer Holder, Electromagnetic and Electromechanical

ANSI/BHMA A156.16 (2013) Auxiliary Hardware

ANSI/BHMA A156.17 (2014) Self Closing Hinges & Pivots

ANSI/BHMA A156.18 (2016) Materials and Finishes

ANSI/BHMA A156.19 (2013) Power Assist & Low Energy Power Operated Doors

ANSI/BHMA A156.2 (2017) Bored and Preassembled Locks and Latches

ANSI/BHMA A156.21 (2014) Thresholds

ANSI/BHMA A156.22 (2012) Door Gasketing and Edge Seal Systems

ANSI/BHMA A156.23 (2010) Electromagnetic Locks

ANSI/BHMA A156.24 (2012) Delayed Egress Locking Systems

ANSI/BHMA A156.25 (2013) Electrified Locking Devices

ANSI/BHMA A156.26 (2012) Continuous Hinges

ANSI/BHMA A156.29 (2012) Exit Locks, Exit Alarms, Alarms for Exit Devices

SECTION 08 71 00 PAGE 1 RTA Submittal Amendment 001

ANSI/BHMA A156.3 (2014) Exit Devices

ANSI/BHMA A156.30 (2014) High Security Cylinders

ANSI/BHMA A156.36 (2010) Auxiliary Locks

ANSI/BHMA A156.4 (2013) Door Controls - Closers

ANSI/BHMA A156.5 (2014) Cylinder and Input Devices for Locks

ANSI/BHMA A156.6 (2015) Architectural Door Trim

ANSI/BHMA A156.7 (2016) Template Hinge Dimensions

ANSI/BHMA A156.8 (2015) Door Controls - Overhead Stops and Holders

NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)

NFPA 101 (2018; TIA 18-1; TIA 18-2; TIA 18-3) Life Safety Code

NFPA 252 (2017) Standard Methods of Fire Tests of Door Assemblies

NFPA 70 (2017; ERTA 1-2 2017; TIA 17-1; TIA 17-2;

TIA 17-3; TIA 17-4; TIA 17-5; TIA 17-6;

TIA 17-7; TIA 17-8; TIA 17-9; TIA 17-10;

TIA 17-11; TIA 17-12; TIA 17-13; TIA

17-14; TIA 17-15; TIA 17-16; TIA 17-17)

National Electrical Code

NFPA 72 (2016; Errata 1 2018) National Fire Alarm and Signaling Code

NFPA 80 (2016; TIA 16-1) Standard for Fire Doors and Other Opening Protectives

STEEL DOOR INSTITUTE (SDI/DOOR)

SDI/DOOR A250.8 (2003; R2008) Recommended Specifications for Standard Steel Doors and Frames

U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)

36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines

UNDERWRITERS LABORATORIES (UL)

UL Bld Mat Dir (updated continuously online) Building Materials Directory

1.2 SUBMITTALS

Government approval is required for submittals with a "G" designation;

SECTION 08 71 00 PAGE 2 RTA Submittal submittals not having a "G" designation are for Contractor Quality Control approval. Submit the following in accordance with Section 01 33 00

SUBMITTAL PROCEDURES:

SD-02 Shop Drawings

Manufacturer's Detail Drawings ; G

Verification of Existing Conditions ; G

Hardware Schedule ; G

Keying System ; G

SD-03 Product Data

Hardware Items ; G

SD-08 Manufacturer's Instructions

Installation

SD-10 Operation and Maintenance Data

Hardware Schedule Items, Data Package 1; G

SD-11 Closeout Submittals

Key Bitting

1.3 SHOP DRAWINGS

Submit manufacturer's detail drawings indicating all hardware assembly components and interface with adjacent construction. Indicate power components and wiring coordination for electrified hardware. Base shop drawings on verified field measurements and include verification of existing conditions .

1.4 PRODUCT DATA

Indicate fire-ratings at applicable components. Provide documentation of ABA/ADA accessibility compliance of applicable components, as required by 36 CFR 1191 Appendix D - Technical.

1.5 HARDWARE SCHEDULE

Prepare and submit hardware schedule in the following form:

Hardware Item

Quantity Size Reference Publi-cation Type No.

Finish Mfr Name and Catalog No.

Key Control Symbols

UL

Mark (If fire-rated and listed)

BHMA

Finish Desig-nation

In addition, submit hardware schedule data package 1 in accordance with

SECTION 08 71 00 PAGE 3 RTA Submittal

Section 01 78 23 OPERATION AND MAINTENANCE DATA.

1.6 KEY BITTING CHART REQUIREMENTS

1.6.1 Requirements

Submit key bitting charts to the Contracting Officer prior to completion of the work. Include:

a. Complete listing of all keys (e.g. AA1 and AA2).

b. Complete listing of all key cuts (AA1-123456, AA2-123458).

c. Tabulation showing which key fits which door.

d. Copy of floor plan showing doors and door numbers.

e. Listing of 20 percent more key cuts than are presently required in each master system.

1.7 QUALITY ASSURANCE

1.7.1 Hardware Manufacturers and Modifications

Provide, as far as feasible, locks, hinges, pivots, and closers of one lock, hinge, pivot, or closer manufacturer's make. Modify hardware as necessary to provide features indicated or specified.

1.7.2 Key Shop Drawings Coordination Meeting

Prior to the submission of the key shop drawing, the Contracting Officer, Contractor, Door Hardware Subcontractor, using Activity and Base Locksmith must meet to discuss and coordinate key requirements for the facility.

1.8 DELIVERY, STORAGE, AND HANDLING

Deliver hardware in original individual containers, complete with necessary appurtenances including fasteners and instructions. Mark each individual container with item number as shown on hardware schedule.

1.9 SUSTAINABLE DESIGN REQUIREMENTS

1.9.1 Final Sustainability eNotebook Submittal

Refer to Section 01 33 29 SUSTAINABILITY REPORTING for federal sustainability product and documentation requirements.

PART 2 PRODUCTS

2.1 TEMPLATE HARDWARE

Hardware applied to metal or to prefinished doors must be manufactured using a template. Provide templates to door and frame manufacturers in accordance with ANSI/BHMA A156.7 for template hinges. Coordinate hardware items to prevent interference with other hardware.

2.2 HARDWARE FOR FIRE DOORS AND EXIT DOORS

Provide all hardware necessary to meet the requirements of NFPA 72 for

SECTION 08 71 00 PAGE 4 RTA Submittal door alarms, NFPA 80 for fire doors, NFPA 101 for exit doors, NFPA 252 for fire tests of door assemblies, ABA/ADA accessibility requirements, and all other requirements indicated, even if such hardware is not specifically mentioned in paragraph HARDWARE SCHEDULE. Provide Underwriters Laboratories, Inc. labels for such hardware in accordance with UL Bld Mat Dir or equivalent labels in accordance with another testing laboratory approved in writing by the Contracting Officer.

2.3 HARDWARE ITEMS

Clearly and permanently mark with the manufacturer's name or trademark, hinges, pivots, locks, latches, exit devices, bolts and closers where the identifying mark is visible after the item is installed. For closers with covers, the name or trademark may be beneath the cover. Coordinate electrified door hardware components with corresponding components specified in Division 28 ELECTRONIC SECURITY SYSTEMS (ESS). Coordinate door hardware with scheduled door Sound Transmission Class (STC) and/or Outdoor-Indoor Transmission Class (OITC) ratings.

2.3.1 Hinges

Provide in accordance with ANSI/BHMA A156.1 . Provide hinges that are 4-1/2 by 4-1/2 inch unless otherwise indicated. Construct loose pin hinges for interior doors and reverse-bevel exterior doors so that pins are non-removable when door is closed. Other anti-friction bearing hinges may be provided in lieu of ball bearing hinges.

2.3.2 Continuous Hinges

Where continuous hinges are required, provide in accordance with

ANSI/BHMA A156.26 .

2.3.3 Pivots

Provide in accordance with ANSI/BHMA A156.17 .

2.3.4 Locks and Latches

2.3.4.1 Mortise Locks and Latches

Provide in accordance with ANSI/BHMA A156.13 , Series 1000, Operational Grade 1, Security Grade 2. Provide knobs and roses of mortise locks with screwless shanks and no exposed screws.

2.3.4.2 Bored Locks and Latches

Provide in accordance with ANSI/BHMA A156.2 , Series 4000, Grade 1.

2.3.4.3 Auxiliary Locks

Provide in accordance with ANSI/BHMA A156.36 , Grade 1.

2.3.5 Exit Devices

Provide in accordance with ANSI/BHMA A156.3 , Grade 1. Provide adjustable strikes for rim type and vertical rod devices. Provide open back strikes for pairs of doors with mortise and vertical rod devices. Provide touch bars in lieu of conventional crossbars and arms. Provide escutcheons not less than 7 by 2-1/4 inch .

SECTION 08 71 00 PAGE 5 RTA Submittal

2.3.6 Exit Locks With Alarm

Provide in accordance with ANSI/BHMA A156.3 and ANSI/BHMA A156.29 , Type E0431 (with full width horizontal actuating bar) for single doors; Type E0431 (with actuating bar) or E0471 (with actuating bar and top and bottom bolts, both leaves active) for pairs of doors, unless otherwise specified. Provide terminals for connection to remote indicating panel.

Provide door alarms integrated with the fire alarm system in accordance with NFPA 72 .

2.3.7 Cylinders and Cores

Provide cylinders for new locks, including locks provided under other sections of this specification. Provide fully compatible cylinders of Grade 1 products from products of one manufacturer with interchangeable cores that are removable by a special control key. Stamp all cores with a key control symbol in a concealed place on the core. Factory set the cores with six pin tumblers using the A2 system and WB keyway. Submit a core code sheet with the cores. Provide master keyed cores in one system for this project. Provide construction interchangeable cores.

2.3.7.1 High Security Cylinders

Provide in accordance with ANSI/BHMA A156.30 , security level B for all high security cylinder components.

2.3.8 Push Button Mechanisms

Provide in accordance with ANSI/BHMA A156.5 , Grade 1.

2.3.9 Electrified Hardware

Comply with the requirements of NFPA 70 for wiring of electrified hardware.

2.3.9.1 Electric Strikes and Frame Mounted Actuators

2.3.9.1.1 Solenoid

Provide actuating solenoid for strikes and actuators that are rated for continuous duty, cannot dissipate more than 12 Watts and must operate on 12 or 24 Volts dc. Inrush current cannot exceed 1 ampere and the holding current cannot be greater than 500 milliamperes. Actuating solenoid must move from fully secure to fully open positions in less than 500 milliseconds.

2.3.9.1.2 Signal Switches

Provide strikes and actuators with signal switches to indicate to the system when the bolt is not engaged or the strike mechanism is unlocked.

Signal switches must report a forced entry to the system.

2.3.9.1.3 Coordination

Provide electric strikes and actuators of a size, weight and profile compatible with each specified door frame. Field verify installation clearances prior to procurement.

Coordinate the layout and installation of scheduled access control door

SECTION 08 71 00 PAGE 6 RTA Submittal hardware, and related access control equipment, with required connection to source power junction boxes, power supply, detection and monitoring hardware.

2.3.9.1.4 Mounting Method

Provide electric strikes and actuators suitable for use with single and double doors, with mortise or rim type hardware specified, and for right or left hand mounting as specified. In double door installations, locate the lock in the active leaf and monitor the fixed leaf.

2.3.9.2 Electrified Mortise Locks

Provide in accordance with ANSI/BHMA A156.25 , Grade 1. Provide electrified mortise locks that remain secure during power failure.

Provide facility interface devices that use dc power to energize solenoids. Provide solenoids, resisters, and signal switches in accordance with paragraph ELECTRIC STRIKES AND FRAME MOUNTED ACTUATORS.

2.3.9.2.1 Power Transfer Hinges

Provide power transfer hinges with each electrified lock that route power and monitoring signals from the lockset to the door frame. Coordinate power transfer hinges with door frames.

2.3.9.3 Card Readers and Keypad Access Control Hardware

Provide in accordance with ANSI/BHMA A156.5 and ANSI/BHMA A156.25 , Grade 1 components. Provide devices that are tamper alarmed, tamper and vandal resistant, solid state, and do not contain electronics which could compromise the access control subsystem should the subsystem be attacked.

Provide surface, semi-flush, or weatherproof mountable devices for each individual location. Provide keypads that contain an integral 12-digit tactile keyboard with digits arranged in numerical order. Provide keypads that are a standalone device or integrated into the card reader.

2.3.9.4 Power Operated Pedestrian Door Hardware

Provide in accordance with ANSI/BHMA A156.10 , Grade 1.

2.3.9.5 Release Devices

In accordance with ANSI/BHMA A156.15 , Grade 1.

2.3.9.5.1 Closer Holders

Provide door mounted closer holder devices connected by integral releasing to smoke detecting devices.

2.3.9.5.2 Release Devices

Provide wall mounted Electromagnetic release devices connected to smoke detecting devices. Provide manual release pushbutton in the immediate vicinity of door. Coordinate location with A/E.

2.3.9.6 Power Assist and Low Energy Power Operated Doors

Provide in accordance with ANSI/BHMA A156.19 , Grade 1.

SECTION 08 71 00 PAGE 7 RTA Submittal

2.3.9.7 Electromagnetic Locks

Provide in accordance with ANSI/BHMA A156.23 , Grade 1. Provide electromagnetic locks that do not contain any moving parts and depend solely upon electromagnetism to secure a portal by generating at least 1200 pounds of holding force. The lock must interface with the local processors without external, internal or functional alteration of the local processor. The electromagnetic lock must incorporate an end of line resistor to facilitate line supervision by the system. Provide metal-oxide resistors (MOVs) to protect controllers from reverse current surges, if not incorporated into the electromagnetic lock or local controller.

2.3.9.7.1 Armature

Provide electromagnetic locks with internal circuitry to eliminate residual magnetism and inductive kickback. Provide atuating armature that operates on 12 or 24 Volts dc and cannot dissipate more than 12 Watts.

Holding current must be less than 500 milliamperes. Actuating armature must take less than 300 milliseconds to change the status of the lock from fully secure to fully open or fully open to fully secure.

2.3.9.7.2 Mounting Method

Provide electromagnetic lock suitable for use with single and double door with mortise or rim type hardware and compatible with right or left hand mounting.

2.3.9.8 Delayed Egress Locking System

Provide in accordance with ANSI/BHMA A156.24 , Grade 1.

2.3.10 Keying System

Provide a grand master keying system. Provide construction interchangeable cores.

Provide sub-master keying system for the building, and keyed to the existing removable core master and grand master keying systems. The Contracting Officer will provide keying information. Key equipment spaces and mechanical rooms separately from the building systems, and key alike to the existing master and grand master systems for these doors.

Provide cylinders of Grade 1 products from one manufacturer. Notify the Contracting Officer 90 days prior to the required delivery of the cylinders. Provide temporary cores and keys for the Contractor's use during construction, and for testing of locksets. Refer to Section 01 11 00 Special Conditions for additional information related to Keying.

2.3.11 Lock Trim

Provide cast, forged, or heavy wrought construction and commercial plain design for lock trim.

2.3.11.1 Knobs and Roses

Provide in accordance with ANSI/BHMA A156.2 and ANSI/BHMA A156.13 for knobs, roses, and escutcheons. For unreinforced knobs, roses, and escutcheons, provide a 0.050 inch thickness. For reinforced knobs, roses, SECTION 08 71 00 PAGE 8 RTA Submittal and escutcheons, provide an outer shell thickness of 0.035 inch and a combined total thickness of 0.070 inch , except at knob shanks. Provide knob shanks 0.060 inch thick.

2.3.11.2 Lever Handles

Provide lever handles where indicated in the Hardware Schedule. Provide in accordance with ANSI/BHMA A156.3 for mortise locks of lever handles for exit devices. Provide lever handle locks with a breakaway feature (such as a weakened spindle or a shear key) to prevent irreparable damage to the lock when force in excess of that specified in ANSI/BHMA A156.13 is applied to the lever handle. Provide lever handles return to within 1/2 inch of the door face.

2.3.11.3 Texture

Provide knurled or abrasive coated knobs or lever handles for doors which are accessible to blind persons and which lead to dangerous areas.

2.3.12 Keys

Furnish one file key, one duplicate key, and one working key for each key change and for each master and grand master keying system. Furnish one additional working key for each lock of each keyed-alike group. Provide construction master keys control keys for removable cores. Stamp each key with appropriate key control symbol and "U.S. property - do not duplicate." Do not place room number on keys.

2.3.13 Door Bolts

Provide in accordance with ANSI/BHMA A156.16 . Provide dustproof strikes for bottom bolts, except at doors having metal thresholds. Provide automatic latching flush bolts in accordance with ANSI/BHMA A156.3 , Type 25.

2.3.14 Closers

Provide in accordance with ANSI/BHMA A156.4 , Series C02000, Grade 1, with PT 4C. Provide with brackets, arms, mounting devices, fasteners, full size covers, except at storefront mounting, pivots, and other features necessary for the particular application. Size closers in accordance with manufacturer's printed recommendations, or provide multi-size closers, Sizes 1 through 6, and list sizes in the Hardware Schedule. Provide manufacturer's 10 year warranty.

2.3.14.1 Identification Marking

Engrave each closer with manufacturer's name or trademark, date of manufacture, and manufacturer's size designation in locations that will be visible after installation.

2.3.15 Overhead Holders

Provide in accordance with ANSI/BHMA A156.8 .

2.3.16 Door Protection Plates

Provide in accordance with ANSI/BHMA A156.6 .

SECTION 08 71 00 PAGE 9 RTA Submittal

2.3.16.1 Sizes of Kick Plates

2 inch less than door width for single doors; 1 inch less than door width for pairs of doors. Provide 8 inch kick plates for flush doors as indicated.

2.3.17 Door Stops and Silencers

Provide in accordance with ANSI/BHMA A156.16 . Silencers Type L03011.

Provide three silencers for each single door, two for each pair.

2.3.18 Thresholds

Provide in accordance with ANSI/BHMA A156.21 . Use J35100, with vinyl or silicone rubber insert in face of stop, for exterior doors opening out, unless specified otherwise. Provide thresholds as required for ATFP and STC performance.

2.3.19 Weatherstripping Gasketing

Provide in accordance with ANSI/BHMA A156.22 . Provide the type and function designation where specified in paragraph HARDWARE SCHEDULE.

Provide a set to include head and jamb seals and, for pairs of doors, astragals. Air leakage of weatherstripped doors not to exceed 1.25 cubic feet per minute of air per square foot of door area when tested in accordance with ASTM E283. Provide weatherstripping with one of the following:

2.3.19.1 Extruded Aluminum Retainers

Extruded aluminum retainers not less than 0.050 inch wall thickness with vinyl, neoprene, silicone rubber, or polyurethane inserts. Provide clear (natural) anodized aluminum.

2.3.19.2 Interlocking Type

Zinc or bronze not less than 0.018 inch thick.

2.3.19.3 Spring Tension Type

Spring bronze or stainless steel not less than 0.008 inch thick.

2.3.20 Soundproofing Gasketing

Provide in accordance with ANSI/BHMA A156.22 . Provide adjustable doorstops at heads,jambs and automatic door bottoms in accordance with the hardware set, of extruded aluminum, clear (natural) anodized, surface applied, with vinyl fin seals between plunger and housing. Provide doorstops with solid neoprene tube, silicone rubber, or closed cell sponge gasket. Provide door bottoms with adjustable operating rod and silicone rubber or closed cell sponge neoprene gasket. Provide doorstops that are mitered at corners. Provide type and function designation where specified in paragraph HARDWARE SETS.

2.3.21 Rain Drips

Provide in accordance with ANSI/BHMA A156.22 . Provide extruded aluminum rain drips, not less than 0.08 inch thick, factory painted finish.

Provide the manufacturer's full range of color choices to the Contracting

SECTION 08 71 00 PAGE 10 RTA Submittal

Officer for color selection Provide rain drips with a 4 inch overlap on each side of each exterior door that is not protected by an awning, roof, eave or other horizontal projection. Set drips in sealant and fasten with stainless steel screws, unless otherwise indicated.

2.3.22 Auxiliary Hardware (Other than locks)

Provide in accordance with ANSI/BHMA A156.16 , Grade 1.

2.3.23 Special Tools

Provide special tools, such as spanner and socket wrenches and dogging keys, as required to service and adjust hardware items.

2.4 FASTENERS

Provide fasteners of type, quality, size, and quantity appropriate to the specific application. Fastener finish to match hardware. Provide stainless steel or nonferrous metal fasteners in locations exposed to weather. Verify metals in contact with one another are compatible and will avoid galvanic corrosion when exposed to weather.

2.5 FINISHES

Provide in accordance with ANSI/BHMA A156.18 . Provide hardware in BHMA 630 finish (satin stainless steel), unless specified otherwise. Provide items not manufactured in stainless steel in BHMA 626 finish (satin chromium plated) over brass or bronze, except aluminum paint finish for surface door closers, and except BHMA 600 finish (primed for painting) for steel hinges where indicated. Provide hinges for exterior doors in stainless steel with BHMA 630 finish or chromium plated brass or bronze with BHMA 626 finish. Furnish exit devices in BHMA 626 finish in lieu of BHMA 630 finish except where BHMA 630 is specified under paragraph HARDWARE SETS. Match exposed parts of concealed closers to lock and door trim. Match hardware finish for aluminum doors to the doors.

2.6 KEY CABINET AND CONTROL SYSTEM

Provide in accordance with ANSI/BHMA A156.5 . Type required to yield a capacity (number of hooks) 50 percent greater than the number of key changes used for door locks.

PART 3 EXECUTION

3.1 INSTALLATION

Provide hardware in accordance with manufacturers' printed installation instructions. Fasten hardware to wood surfaces with full-threaded wood screws or sheet metal screws. Provide machine screws set in expansion shields for fastening hardware to solid concrete and masonry surfaces.

Provide toggle bolts where required for fastening to hollow core construction. Provide through bolts where necessary for satisfactory installation.

3.1.1 Weatherstripping Installation

Provide full contact, weathertight seals that allow operation of doors without binding the weatherstripping.

SECTION 08 71 00 PAGE 11 RTA Submittal

3.1.1.1 Stop Applied Weatherstripping

Fasten in place with color matched sheet metal screws not more than 9 inch on center after doors and frames have been finish painted.

3.1.1.2 Interlocking Type Weatherstripping

Provide interlocking, self adjusting type on heads and jambs and flexible hook type at sills. Nail weatherstripping to door 1 inch on center and to heads and jambs at 4 inch on center.

3.1.1.3 Spring Tension Type Weatherstripping

Provide spring tension type on heads and jambs. Provide bronze nails with bronze. Provide stainless steel nails with stainless steel. Space nails not more than 1-1/2 inch on center.

3.1.2 Soundproofing Installation

Provide as specified for stop applied weatherstripping. Coordinate with associated systems or accessories with Section 08 34 73 SOUND CONTROL DOOR

ASSEMBLIES.

3.1.3 Threshold Installation

Extend thresholds the full width of the opening and notch end for jamb stops. Set thresholds in a full bed of sealant and anchor to floor with cadmium-plated, countersunk, steel screws.

3.2 FIRE DOORS AND EXIT DOORS

Provide hardware in accordance with NFPA 72 for door alarms, NFPA 80 for fire doors, NFPA 101 for exit doors, and NFPA 252 for fire tests of door assemblies.

3.3 HARDWARE LOCATIONS

Provide in accordance with SDI/DOOR A250.8 , unless indicated or specified otherwise.

a. Kick Plates: Push side of single-acting doors. Both sides of double-acting doors.

b. Mop Plates: Bottom flush with bottom of door.

3.4 KEY CABINET AND CONTROL SYSTEM

Locate where directed. Tag one set of file keys and one set of duplicate keys. Place other keys in appropriately marked envelopes, or tag each key. Provide complete instructions for setup and use of key control system. On tags and envelopes, indicate door and room numbers or master or grand master key.

3.5 FIELD QUALITY CONTROL

After installation, protect hardware from paint, stains, blemishes, and other damage until acceptance of work. Submit notice of testing 15 days before scheduled, so that testing can be witnessed by the Contracting Officer. Adjust hinges, locks, latches, bolts, holders, closers, and

SECTION 08 71 00 PAGE 12 RTA Submittal other items to operate properly. Demonstrate that permanent keys operate respective locks, and give keys to the Contracting Officer. Correct, repair, and finish, errors in cutting and fitting and damage to adjoining work.

3.6 DOOR HARDWARE SETS

The door hardware sets represent the design intent and direction of the owner and architect. They are a guideline only and should not be considered a detailed hardware schedule. Discrepancies, conflicting hardware and missing items should be brought to the attention of the architect with corrections made prior to the bidding process. Omitted items not included in a hardware set should be scheduled with the appropriate additional hardware required for proper application and functionality.

The supplier is responsible for handing and sizing all products as listed in the door hardware sets. Quantities listed are for each pair of doors, or for each single door.

Manufacturer's Abbreviations:

MK - McKinney MR - Markar PE - Pemko SU - Securitron RO - Rockwood SA - Sargent GS - ASSA ABLOY Glass Solutions KA - Kaba Ilco SG - Sargent & Greenleaf Inc BE - Best Access Systems RF - Rixson NO - Norton YA - Yale

Set: 1 Doors: 100

1 Continuous Hinge CFMSLF-HD1 x PT PE 1 Electric Power Transfer EL-CEPT SU 1 CVR Exit Device 43 53 55 56 72 AD8610 106 x 862 US32D SA 1 Core 1C-7 626 BE 1 Overhead Stop 1-SERIES 630 RF 1 Auto Operator 6300 SERIES x 120V 689 NO 1 Door Switch 501 NO 1 Door Switch 503 NO 1 Threshold 252x3AFG PE 1 Weatherseal BY ALUMINUM DOOR SUPPLIER 1 Sweep 345CV PE 1 ElectroLynx Harness QC-C x LENGTH REQ'D. MK 1 ElectroLynx Harness QC-C1500P MK 1 Power Supply BPS-24 YA 1 Door Contact BY SECURITY CONTRACTOR 1 Card Reader/Key Pod BY SECURITY CONTRACTOR 1 Wiring Diagrams ELEVATION & POINT-TO-POINT

Operational Description: During OPEN hours (programmed through access control system) latches of exit devices are electronically held retracted, SECTION 08 71 00 PAGE 13 RTA Submittal exterior door switch is enabled and opening functions as manual push/pull or assisted entry/egress by pressing door switch to activate automatic operator on door leaf. During CLOSED hours (programmed through access control system) latches of exit devices are electronically secured and exterior door switch is disabled. Entry by key in cylinder at door leaf.

Manual egress at all times by pressing rail of exit device and exiting.

Pressing rail of either exit device shunts door contacts for authorized egress.

Door contacts monitor the position of the doors and report this status to the security system. Contractor to coordinate with security drawings.

Set: 2 Doors: 101

1 Continuous Hinge CFMSLF-HD1 x PT PE 1 Electric Power Transfer EL-CEPT SU 1 CVR Exit Device 43 53 55 56 72 AD8610 106 x 862 US32D SA 1 Core 1C-7 626 BE 1 Overhead Stop 1-SERIES 630 RF 1 Auto Operator 6300 SERIES x 120V 689 NO 1 Door Switch 503 NO 1 Power Supply BPS-24 YA

Operational Description: During OPEN hours (programmed through access control system) latches of exit devices are electronically held retracted, vestibule door switch is enabled and opening functions as manual push/pull or assisted entry/egress by pressing either door switch to activate automatic operator on door leaf. During CLOSED hours (programmed through access control system) latches of exit devices are electronically secured and exterior door switch is disabled. Entry by key in cylinder. Manual egress at all times by pressing rail of either exit device and exiting.

Pressing rail of exit device shunts door contacts for authorized egress.

Door contacts monitor the position of the doors and report this status to the security system.

Set: 3 Doors: 123 B

1 Security Dev (EXIT ONLY) LKM7002 (FF-L-2890) 630 KA 1 Closer UNI7500 689 NO 1 Kick Plate K1050 - 10" x 2" LDW x BEV x CSK US32D RO 1 Door Contact BY SECURITY CONTRACTOR

HINGES, SEALS, BOTTOM AND THRESHOLD BY STC ASSEMBLY SUPPLIER.

Door contact monitors the position of the door and reports this status to the security system. Contractor to coordinate with security drawings.

Set: 4 Doors: 127

2 Continuous Hinge FM300 630 MR 1 Keyed Rem Mullion L980 PC SA 1 Cylinder Mullion Kit 72-980C1 US32D SA 2 CVR Exit Device 43 53 55 56 72 AD8610 106 x 862 US32D SA 2 Rim Cylinder 72 41 US32D SA 3 Core 1C-7 626 BE 2 Closer UNI7500 689 NO

SECTION 08 71 00 PAGE 14 RTA Submittal

2 Kick Plate K1050 - 10" x 2" LDW x BEV x CSK US32D RO 1 Threshold 252x3AFG PE 1 Gasketing 312CR PE 2 Sweep 345CV PE 1 Split Astragal 305CN PE 2 Door Contact BY SECURITY CONTRACTOR

Door contacts monitor the position of the doors and report this status to the security system.

Set: 5 Doors: 121B

1 Electric Power Transfer EL-CEPT SU 2 Surface Bolt 585-12 US26D RO 1 Electrified Mortise Lock 72 NAC-82271-24v LNP US26D SA 1 Core 1C-7 626 BE 1 Overhead Stop 9-SERIES 630 RF 1 Closer UNI7500 689 NO 2 Kick Plate K1050 - 10" x 1" LDW x BEV x CSK US32D RO 1 Astragal 355CS PE 1 ElectroLynx Harness QC-C x LENGTH REQ'D. MK 1 ElectroLynx Harness QC-C1500P MK 1 Power Supply EPS-05 SU 1 Card Reader/Key Pad BY SECURITY CONTRACTOR 2 Door Contact BY SECURITY CONTRACTOR 1 Wiring Diagrams ELEVATION & POINT-TO-POINT

HINGES, SEALS, DOOR BOTTOM AND THRESHOLD BY STC ASSEMBLY SUPPLIER.

Operational Description: Doors are normally closed and locked. Presenting a valid card/code to card reader/keypad will momentarily unlock outside lever of lockset at RHR leaf allowing entry. Entry also by key in cylinder at RHR leaf. Egress at all times by operating inside lever and exiting.

Operating inside lever will shunt door contacts for authorized egress (REX). Door contacts monitor the position of the doors and report this status to the security system. Contractor to coordinate with security drawings.

Set: 6 Doors: 118, 120, 122

4 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Office Lock 72 8205 LNP US26D SA 1 Core 1C-7 626 BE 1 Wall Stop 409 US32D RO

Set: 7 Doors: 121A

4 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Electric Power Transfer EL-CEPT SU 1 Electrified Mortise Lock 72 NAC-82271-24v LNP US26D SA 1 Core 1C-7 626 BE 1 Closer PR7500 689 NO 1 Kick Plate K1050 - 10" x 2" LDW x BEV x CSK US32D RO 1 Wall Stop 409 US32D RO 1 Power Supply EPS-05 SU

SECTION 08 71 00 PAGE 15 RTA Submittal

1 Door Contact BY SECURITY CONTRACTOR 1 Wiring Diagrams ELEVATION & POINT-TO-POINT

Operational Description: Door is normally closed and locked. Entry also by key in cylinder. Manual egress by operating inside lever and exiting.

Operating inside lever will shunt door contact for authorized egress.

Door contact monitors the position of the door and report this status to the security system. Contractor to coordinate with security drawings.

Set: 8 Doors: 103, 104, 105, 113, 114

1 Office Lock 72 8205 LNP US26D SA 1 Core 1C-7 626 BE 1 Wall Stop 409 US32D RO

HINGES, SEALS, DOOR BOTTOM AND THRESHOLD BY STC ASSEMBLY SUPPLIER.

Set: 9 Doors: 128

4 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Store Room Lock 72 8204 LNP US260 SA 1 Core 1C-7 626 BE 1 Closer CPS7500 689 NO 1 Kick Plate K1050 - 10" x 2" LDW x BEV x CSK US32D RO 1 Gasketing S88BL PE 1 Wall Stop 409 US32D RO

Set: 10 Doors: 108, 111, 112

1 Electric Power Transfer EL-SEPT SU 1 Passage Set 8215 LNP US26D SA 1 Electrified Mortise Lock 72 NAC-82271-24v LNP US26D SA 1 Core 1C-7 626 BE 1 Closer 7500 689 NO 1 Kick Plate K1050 - 10" x 2" LDW x BEV x CSK US32D RO 1 Wall Stop 409 US32D RO 1 ElectroLynx Harness QC-C x LENGTH REQ'D. MK 1 ElectroLynx Harness QC-C1500P MK 1 Power Supply EPS-05 SU 1 Card Reader/Key Pad BY SECURITY CONTRACTOR 1 Door Contact BY SECURITY CONTRACTOR 1 Wiring Diagrams ELEVATION & POINT-TO-POINT

Operational Description: Door is normally closed and locked. Presenting a valid card/code to card reader/key pad will momentarily unlock outside lever of lockset, allowing entry. Entry also by key in cylinder. Manual egress by operating inside lever and exiting. Operating inside lever will shunt door contact for authorized egress.

Door contact monitors the position of the door and report this status to the security system.

HINGES, SEALS, DOOR BOTTOM AND THRESHOLD BY STC ASSEMBLY SUPPLIER.

Set: 11 Doors: 119

SECTION 08 71 00 PAGE 16 RTA Submittal

4 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Electric Power Transfer EL-SEPT SU 1 Electrified Mortise Lock 72 NAC-82271-24v LNP US26D RO 1 Door Contact BY SECURITY CONTRACTOR 1 Wiring Diagram ELEVATION & POINT-TO-POINT 1 Passage Set 8215 LNP US26D SA 1 Wall Stop 409 US32D RO

Operational Description: Door is normally closed and locked. Entry also by key in cylinder. Manual egress by operating inside lever and exiting.

Operating inside lever will shunt door contact for authorized egress.

Door contact monitors the position of the door and report this status to the security system. Contractor to coordinate with security drawings.

Set: 12 Doors: 109, 110

4 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Push Plate 70C-RKW (4 x 16) US32D RO 1 Pull RM301 US32D RO 1 Closer R7500 689 NO 1 Kick Plate K1050 - 10" x 2" LDW x BEV x CSK US32D RO 1 Wall Stop 409 US32D RO

Set: 13 Doors: 107

4 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Store Room Lock 72 8204 LNP US26D SA 1 Core 1C-7 626 BE 1 Closer CPS7500 689 NO 1 Kick Plate K1050 - 10" x 2" LDW x BEV x CSK US32D RO 1 Wall Stop 409 US32D RO

Set: 14 Doors: 108

4 Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Core 1C-7 626 BE 1 Closer R7500 689 NO 1 Kick Plate K1050 - 10" x 2" LDW x BEV x CSK US32D RO 1 Mop Plate 409 US32D RO 1 Wiring Diagram ELEVATION & POINT-TO-POINT

Operational Description: Door is normally closed and locked. Presenting a valid card to card reader on lockset will momentarily unlock outside lever, allowing entry. Entry also by key in cylinder. Egress at all times by operating inside lever and exiting. Operating inside lever will shunt door contact for authorized egress (REX). Door contact monitors the position of the door and reports this status to the security system.

Set: 15 Doors: 115, 116, 117, 124, 125, 24

Coordinate hardware with corresponding systems or accessories as specified in selection.

-- End of Section --

SECTION 08 71 00 PAGE 17 RTA Submittal

SECTION 08 71 00 PAGE 18 RTA Submittal

File details come from the government source that posted it. Updated .