Attachment 6 (8) Spec 10 51 1301 (new spec) Amendment.pdf

PDF 26 KB Posted

Attached to
Cyber Operations Facility
Solicitation number
W9123621B2013
Issued by

About this file

This document contains specifications for metal cell phone lockers to be installed at a new Cyber Operations Facility for the Department of the Army Corps of Engineers Engineering District Norfolk. The specifications require the supply and installation of 48 lockers minimum, with single and double-tier configurations available in various widths and depths. Materials must be aluminum or galvanized steel sheet with a powder coated finish. Lockers must have built-in key or combination locks, coat hooks, door handles, and identification number plates. Installation includes assembly, alignment, and securing lockers to walls and bases with bolting and screws. The related federal contract opportunity is a solicitation posted under number W91236-21-B-2013 for the construction of the new Cyber Operations Facility project.

View the file

Other files

Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

185th CYBER OPS FACILITY W91236-17-D-0001

JOINT BASE LANGLEY-EUSTIS, VA

SECTION 10 51 13 .01

METALCELL PHONE LOCKERS

05/11

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

ASTM INTERNATIONAL (ASTM)

ASTM B209-14 (2016) Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate

U.S. GENERAL SERVICES ADMINISTRATION (GSA)

FS AA-L-00486 (Rev J) Lockers, Clothing, Steel

1.2 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are [ for Contractor Quality Control approval. ][for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government.] Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section

01 33 00 SUBMITTAL PROCEDURES:

SD-02 Shop Drawings

Types; G

Location; G

Installation

[ Numbering system ]

SD-03 Product Data

Material

Locking Devices

[ Lock Control Chart ]

Handles

Finish

Locker components

Assembly instructions

SECTION 10 51 13.01 Page 1 AMENDMENT 1

SD-04 Samples

Color chips; G

1.3 DELIVERY, HANDLING, AND STORAGE

Deliver lockers and associated materials in their original packages, containers, or bundles bearing the manufacturer's name and the name of the material. Protect from weather, soil, and damage during delivery, storage, and construction.

1.4 FIELD MEASUREMENTS

To ensure proper fits, make field measurements prior to the preparation of drawings and fabrication. Verify correct location .

1.5 QUALITY ASSURANCE

1.5.1 Color Chips

Provide a minimum of three color chips, not less than 3 inches square, of each color [scheduled] [ indicated ] .

Government may request performance-characteristic tests on assembled lockers. Tests and results must conform to FS AA-L-00486 . Lockers not conforming will be rejected.

PART 2 PRODUCTS

2.1 TYPES

Locker must have the following type and size in the location and quantities indicated number of openings indicated . Provide Ll ocker finish colors will be as scheduled from cell phone locker manufacturer's standard full range of colors .

2.1.1 Single-tier Lockers Cell Phone Locker Units

Single-tier lockers must be as follows: Cell phone locker units must be recessed - mounted and as follows:

[ Type STL-1: Single-tier locker 15 inches wide, 15 inches deep, and 72 inches high, attached to 6-inch high legs ]

[ Type STL-2: Single-tier locker 15 inches wide, 18 inches deep, and 72 inches high, attached to 6-inch high legs ]

[ Type STL-3: Single-tier locker 18 inches wide, 21 inches deep, and 72 inches high, attached to 6-inch high legs ]

[ Type STL-4: Single-tier locker 18 inches wide, 24 inches deep, and 72 inches high, attached to 6-inch high legs ]

[ Type STC-1: Single-tier locker 15 inches wide, 15 inches deep, and 72 inches high, attached to 6-inch closed base ]

[ Type STC-2: Single-tier locker 15 inches wide, 18 inches deep, and 72 inches high, attached to 6-inch high closed base ]

SECTION 10 51 13.01 Page 2 AMENDMENT 1

[ Type STC-3: Single-tier locker 18 inches wide, 21 inches deep, and 72 inches high, attached to 6-inch high closed base ]

[ Type STC-4: Single-tier locker 18 inches wide, 24 inches deep, and 72 inches high, attached to 6-inch high closed base ]

[ Type STW-2: Single-tier locker 15 inches wide, 18 inches deep, and 72 inches high, without base ]

[ Type STW-3: Single-tier locker 18 inches wide, 21 inches deep, and 72 inches high, without base ]

[ Type STW-4: Single-tier locker 18 inches wide, 24 inches deep, and 72 inches high, without base ] a. Units accommodates cell phones, keys, wallets, cameras, tablets PC's and other valuable items.

b. Made entirely of heavy duty aluminum.

c. One compartment for each unit shall include panel lock and may or may not be used for cell phone storage.

d. Front access panel swings on a heavy-duty continuous hinge.

e. Feature a durable powder coated finish in manufacturer's standard color.

f. Cell phone locker units shall have master keyed locks that allow access to all compartments.

g. All openings in locker units shall be usable.

h. Each compartment's door shall have master keyed locks.

i. Each cell phone locker door includes a minimum of 2 inch wide x 5/8" high clear plastic card holder (card included) to identification or for numbering each compartment.

2.1.2 Double-Tie Locker Unit Configuration

Double-tier lockers must be as follows: Must be (5) wide to fit 3'-0" wide wall clear opening indicated on drawings. Provide two stack of (5) tier as required to meet number of compartments indicated.

Type DTL-1: Double-tier locker 15 inches wide, 15 inches deep, and 72 inches high, attached to 6-inch high legs

Type DTL-2: Double-tier locker 15 inches wide, 18 inches deep, and 72 inches high, attached to 6-inch high legs

Type DTC-1: Double-tier locker 15 inches wide, 15 inches deep, and 72 inches high, attached to a 6-inch high closed base

Type DTC-2: Double-tier locker 15 inches wide, 18 inches deep, and 72 inches high, attached to a 6-inch high closed base

Type DTW-1: Double-tier locker 15 inches wide, 15 inches deep, and 72 inches high, without base

SECTION 10 51 13.01 Page 3 AMENDMENT 1

Type DTW-2: Double-tier locker 15 inches wide, 18 inches deep, and 72 inches high, without base

2.1.3 Locker Compartments

Total number of locker compartments: 48 minimum.

2.1.4 Locker Unit Depth

Locker unit depth: 8 3/4" deep minimum.

2.2 MATERIAL

2.2.1 [Galvanized] Steel Sheet Aluminum Sheet

[[ ASTM A1008/A1008M B209-14 ] [ ASTM A568/A568M ] , commercial quality, minimized spangle material. Prepare material surfaces for [baked enamel] [_____] powder coating finishing in accordance with FS AA-L-00486 . [ Fabricate locker bodies from not less than 0.0239-inch thick steel sheet.][ Minimum 16 ga. aluminum uncoated sheet uncoated sheet thickness [as specified] [_____] . ]]

[ ASTM A653/A653M and ASTM A924/A924M , commercial quality, minimized spangle, galvanized steel sheet with not less than G60 zinc coating.

Prepare surface of sheet for painting in accordance with ASTM D6386, Method A. Minimum uncoated sheet thickness [as specified] [_____].]

2.2.2 Chromium Coating

Nickel and chromium electrodeposited on the specified base metal. Conform to ASTM B456, SC-3, as applicable to the base metal.

2.2.2 Finish

[ FS AA-L-00486 . ] Powder Coated Finish.

[Primer, [ MIL-PRF-23377 ] [_____]; topcoat, [ MIL-PRF-22750 ] [_____].]

2.2.2.1 Color and Texture

As selected. As selected from manufacturer's standard full range of color.

2.3 COMPONENTS

2.3.1 Built-In Locks

[ FS AA-L-00486 . Provide locking devices as [built-in key locks] [built-in combination locks] [and] [a padlock eye in the door latching mechanism].][ Submit Lock Control Chart showing each lock required for the project, the locker identification plate number, and the lock combination. ]

[Built-in locks are not required.]

2.3.2 Coat Hooks

FS AA-L-00486 , [chromium] [zinc] plated.

2.3.3 [ Hanger Rods

FS AA-L-00486 .

SECTION 10 51 13.01 Page 4 AMENDMENT 1

] 2.3.4 Door Handles

FS AA-L-00486 . [Provide zinc alloy or steel handles with a chromium coating.]

2.3.2 Doors

FS AA-L-00486 , not less than 0.0598 inch thick steel sheet.

2.3.2.1 Hinges

In addition to the requirements of FS AA-L-00486 , provide 5-knuckle hinges, minimum 2 inches high. Fabricate knuckle hinges from not less than

0.0787 inch thick steel sheet. [A full height piano hinge may be provided if standard with the manufacturer.] Weld or bolt hinges to the door frame. Weld, bolt, or rivet hinges to the door.

2.3.2.1 Latching Mechanisms

FS AA-L-00486 .

2.3.3 Latch Strikes

FS AA-L-00486 . Fabricate from not less than 0.0787 inch thick steel sheet, except latch strike may be continuous from top to bottom and fabricated as part of the door framing.

2.3.4 Silencers

FS AA-L-00486 .

2.3.5 Back and Side Panels, Tops, and Bottoms

FS AA-L-00486 , not less than 0.0474 inch thick steel sheet.

[ 2.3.6 Sloping Locker Tops

Provide sloping locker tops in addition to the locker-section flat tops.

Sloping tops must be continuous in length. Provide fillers or closures at the exposed end of sloping tops. Fabricate sloping tops from not less than 0.0478-inch thick steel sheet.

] 2.3.7 Shelves

FS AA-L-00486 . Fabricate from not less than 0.0598 inch thick steel sheet.

2.3.8 [ Base Panels

FS AA-L-00486 .

] 2.3.9 Legs

[ FS AA-L-00486 .] [Provide lockers without legs, as indicated.]

2.3.10 Number Plates

[ FS AA-L-00486 . [Aluminum] [Brass] [Zinc]. Provide consecutive numbers from [_____] to [_____].]

SECTION 10 51 13.01 Page 5 AMENDMENT 1

[Number plates are not required.]

2.3.11 [ Label Holders

FS AA-L-00486 .

] 2.3.4 Fastening Devices

Provide bolts, nuts, and rivets as specified in FS AA-L-00486 or as recommended by cell phone lockers manufacturer.

PART 3 EXECUTION

3.1 ASSEMBLY AND INSTALLATION

Assemble lockers according to the locker manufacturer's instructions.

Align lockers horizontally and vertically. Secure lockers to wall s [ and base ] with screws as indicated . Bolt adjacent lockers together. Adjust doors to operate freely without sticking or binding and to ensure they close tightly. Where two stacks of cell phone locker unit is required, bolt lockers together.

3.2 [ NUMBERING SYSTEM

Install number plates on lockers consecutively [with odd numbers on top and even numbers on bottom] [as indicated] [_____].

] 3.2 FIELD QUALITY CONTROL

3.2.1 Testing

Government may request performance-characteristic tests on assembled lockers in accordance with FS AA-L-00486 . Lockers not conforming will be rejected.

3.2.2 Repairing

Remove and replace damaged and unacceptable portions of completed work with new.

3.2.3 Cleaning

Clean surfaces of the work, and adjacent surfaces soiled as a result of the work, in an approved manner. Remove equipment, surplus materials, and rubbish from the site.

-- End of Section --

SECTION 10 51 13.01 Page 6 AMENDMENT 1

File details come from the government source that posted it. Updated .