Cover
ATTACHMENT 8:
CONTRACTOR PROPOSED QUANTITIES
STARTS ON FOLLOWING PAGE
Summary
| ITEM: | DESCRIPTION: | OFFEROR: |
| SUMMARY | SUMMARY PAGE |
| ITEM: | DESCRIPTION: | QUANTITY: | UNIT: |
| 0022AB | BORING ENTRY INTO gINT | EACH | |
| 0037AB | AUTOMATED GROUTING CONTROL AND DATA COLLECTION SYSTEM | HOUR | |
| 0038AB | DRILLING IN SOIL, GROUT HOLES | LINEAR FOOT | |
| 0039AB | DRILLING IN BEDROCK, GROUT HOLES | LINEAR FOOT | |
| 0040AB | OPTICAL TELEVIEWER SURVEYING, GROUT HOLES | LINEAR FOOT | |
| 0041AB | PRESSURE TESTING, GROUT HOLES | EACH | |
| 0042AB | GROUTING | HOUR | |
| 0043AB | GROUT MIX A | CUBIC FOOT | |
| 0044AB | GROUT MIX B | CUBIC FOOT | |
| 0045AB | GROUT MIX C | CUBIC FOOT | |
| 0046AB | GROUT MIX D | CUBIC FOOT | |
| 0047AB | GROUT MIX E1 - WITHOUT ANTIWASHOUT | CUBIC FOOT | |
| 0048 | GROUT MIX E2 - WITH ANTIWASHOUT | CUBIC FOOT | |
| 0049AB | GROUT MIX F1 - SAND WITHOUT ANTIWASHOUT | CUBIC FOOT | |
| 0050 | GROUT MIX F2 - SAND WITH ANTIWASHOUT | CUBIC FOOT | |
| 0051AB | DRILLING AND BACKFILLING, VERIFICATION HOLES, GROUTED ZONE | LINEAR FOOT | |
| 0052AB | CORE DRILLING AND BACKFILLING, VERIFICATION HOLES, GROUTED ZONE | LINEAR FOOT | |
| 0053AB | OPTICAL TELEVIEWER SURVEYING, VERIFICATION HOLES, GROUTED ZONE | LINEAR FOOT | |
| 0054AB | PRESSURE TESTING, VERIFICATION HOLES, GROUTED ZONE | EACH | |
| 0062AB | ANTIWASHOUT ADMIXTURE FOR CUTOFF WALL | GALLON | |
| 0079AB | SINGLE-STAGE BACKFILLING AROUND CASING, GROUT HOLES | LINEAR FOOT | |
| 0080AB | MULTI-STAGE BACKFILLING AROUND CASING, GROUT HOLES | LINEAR FOOT | |
| 0081AB | RE-DRILLING, GROUT HOLES | LINEAR FOOT | |
| 0082AB | ADDITIONAL DRILLING AND GROUT HOLE SETUPS | EACH |
&10EAST BRANCH CUTOFF WALL
| W911WN-13-R-0002 | &"Times New Roman,Bold" CONTRACTOR PROPOSED |
| QUANTITIES BACKUP SHEET | &P of &N |
SC Grout Summary Table
| ITEM: | DESCRIPTION: | OFFEROR: |
| SUMMARY | SLURRY CONTROL GROUTING SUMMARY TABLE |
| ELEVATION | 0038AB | 0039AB | 0041AB | 0042AB | 0043AB | 0044AB | 0045AB | 0046AB | 0047AB | 0048 | 0049AB | 0050AB | 0079/80AB | |||||||
| LINE | ||||||||||||||||||||
| (U/S or D/S) | ORDER | |||||||||||||||||||
| (P,S,T,O) | STATION | TOP OF HOLE | TOP OF ROCK | BOTTOM OF HOLE | DRILLING IN SOIL | DRILLING IN ROCK | PRESSURE TESTS | GROUTING | MIX A | MIX B | MIX C | MIX D | MIX E1 | MIX E2 | MIX F1 | MIX F2 | TOTAL GROUT | BACK-FILLING |
TOTALS
&10EAST BRANCH CUTOFF WALL
| W911WN-13-R-0002 | &"Times New Roman,Bold" CONTRACTOR PROPOSED |
| QUANTITIES BACKUP SHEET | &P of &N |
Enter Offeror Name U/S = Upstream D/S = Downstream P = Primary S = Secondary T = Tertiary O = Higher Order All Units in Feet Each Hours Cubic Feet Feet Please provide quantity calculations for fill-in quantities ONLY. Format cells & add rows/columns as necessary. Delete word art and shapes(arrows).
Quantities shall include Offeror proposed slurry control grouting as well as any proposed interface treatment using grout in the slurry control grout holes. Offerors may also make assumptions on what mixes will be required for each hole, including not using some mixes at all.
0022AB
| ITEM: | DESCRIPTION: | OFFEROR: |
| 0022AB | BORING ENTRY INTO gINT |
| TYPE | ||
| (E,P,O) | STATION |
| NUMBER OF EXPLORATORY, PILOT AND/OR OTHER HOLES PROPOSED ABOVE | EACH |
| NUMBER OF SLURRY CONTROL GROUT HOLES PROPOSED | EACH |
| NUMBER OF SLURRY CONTROL GROUT VERIFICATION HOLES PROPOSED | EACH |
0022AB, BORING ENTRY INTO gINT (Fill-In Quantity Only) EACH
&10EAST BRANCH CUTOFF WALL
| W911WN-13-R-0002 | &"Times New Roman,Bold" CONTRACTOR PROPOSED |
| QUANTITIES BACKUP SHEET | &P of &N |
Enter Offeror Name Please provide quantity calculations for fill-in quantities ONLY. Format cells & add rows/columns as necessary. Delete word art and shapes(arrows).
E = Exploratory P = Pilot O = Other Boring entry into gINT is required for all proposed slurry control grout holes, any proposed slurry control grout verification holes, any additional exploratory holes proposed, as well as any pilot holes.
0037AB
| ITEM: | DESCRIPTION: | OFFEROR: |
| 0037AB | AUTOMATED GROUTING CONTROL AND DATA COLLECTION SYSTEM |
| FROM SC GROUT SUMMARY TABLE | ||||
| # OF HOLES | DRILLING IN SOIL | DRILLING IN ROCK | VOLUME OF GROUT | |
| TOTALS |
| 0037AB, HOURS OF AGCDCS (Fill-In Quantity Only) | HOURS | |
| Assumptions & Calculations: |
&10EAST BRANCH CUTOFF WALL
| W911WN-13-R-0002 | &"Times New Roman,Bold" CONTRACTOR PROPOSED |
| QUANTITIES BACKUP SHEET | &P of &N |
In this area, provide basic assumptions in regards to assumed hours the Automated Grout Control and Data Collection System will be onsite/utilized in accordance with Section 01 22 00.00 10 for the fill-in quantity ONLY. Offerors should provide assumptions related to hours worked per shift, shifts worked per day, and shifts worked per week. Table of slurry control grouting totals is provided above to give USACE a rough idea of how much grouting is proposed for the associated fill-in quantities. Offerors are not required to provide assumed production rates or the connection between table above and number of hours proposed for the AGCDCS.
Please provide quantity calculations for fill-in quantities ONLY. Format cells & add rows/columns as necessary. Delete word art and shapes(arrows).
Enter Offeror Name
0038AB
| ITEM: | DESCRIPTION: | OFFEROR: |
| 0038AB | DRILLING IN SOIL, GROUT HOLES |
0038AB, DRILLING IN SOIL, GROUT HOLES (Fill-In Quantity Only) FEET
| W911WN-13-R-0002 | &"Times New Roman,Bold" CONTRACTOR PROPOSED |
| QUANTITIES BACKUP SHEET | &P of &N |
Please provide quantity calculations for fill-in quantities ONLY. Format cells & add rows/columns as necessary. Delete word art and shapes(arrows).
Enter Offeror Name Enter total from SC Grout Summary Table for Drilling in Soil
0039AB
| ITEM: | DESCRIPTION: | OFFEROR: |
| 0039AB | DRILLING IN BEDROCK, GROUT HOLES |
0039AB, DRILLING IN BEDROCK, GROUT HOLES (Fill-In Quantity Only) FEET
| W911WN-13-R-0002 | &"Times New Roman,Bold" CONTRACTOR PROPOSED |
| QUANTITIES BACKUP SHEET | &P of &N |
Please provide quantity calculations for fill-in quantities ONLY. Format cells & add rows/columns as necessary. Delete word art and shapes(arrows).
Enter Offeror Name Enter total from SC Grout Summary Table for Drilling in Bedrock
0040AB
| ITEM: | DESCRIPTION: | OFFEROR: |
| 0040AB | OPTICAL TELEVIEWER SURVEYING, GROUT HOLES |
| FROM 0039AB DRILLING IN BEDROCK, GROUT HOLES | FEET | |
| x15% |
0040AB, OPTICAL TELEVIEWER SURVEYING, GROUT HOLES (Fill-In Quantity Only) FEET
| W911WN-13-R-0002 | &"Times New Roman,Bold" CONTRACTOR PROPOSED |
| QUANTITIES BACKUP SHEET | &P of &N |
Please provide quantity calculations for fill-in quantities ONLY. Format cells & add rows/columns as necessary. Delete word art and shapes(arrows).
Enter Offeror Name All Offerors are to assume 15% of the rock drilling quantity proposed as the fill-in quantity under 0039AB will be surveyed.
0041AB
| ITEM: | DESCRIPTION: | OFFEROR: |
| 0041AB | PRESSURE TESTING, GROUT HOLES |
0041AB, PRESSURE TESTING, GROUT HOLES (Fill-In Quantity Only) EACH
| W911WN-13-R-0002 | &"Times New Roman,Bold" CONTRACTOR PROPOSED |
| QUANTITIES BACKUP SHEET | &P of &N |
Please provide quantity calculations for fill-in quantities ONLY. Format cells & add rows/columns as necessary. Delete word art and shapes(arrows).
Enter Offeror Name Enter total from SC Grout Summary Table for Pressure Tests
0042AB
| ITEM: | DESCRIPTION: | OFFEROR: |
| 0042AB | GROUTING |
0042AB, GROUTING (Fill-In Quantity Only) HOUR
| W911WN-13-R-0002 | &"Times New Roman,Bold" CONTRACTOR PROPOSED |
| QUANTITIES BACKUP SHEET | &P of &N |
Enter Offeror Name Please provide quantity calculations for fill-in quantities ONLY. Format cells & add rows/columns as necessary. Delete word art and shapes(arrows).
Enter total from SC Grout Summary Table for Grouting Quantities shall include Offeror proposed slurry control grouting as well as any proposed interface treatment using grout in the slurry control grout holes.
0043AB
| ITEM: | DESCRIPTION: | OFFEROR: |
| 0043AB | GROUT MIX A |
| 0043AB, GROUT MIX A (Fill-In Quantity Only) | CF | |
| Brief Assumptions/Justifications: |
| W911WN-13-R-0002 | &"Times New Roman,Bold" CONTRACTOR PROPOSED |
| QUANTITIES BACKUP SHEET | &P of &N |
Enter Offeror Name Please provide quantity calculations for fill-in quantities ONLY. Format cells & add rows/columns as necessary. Delete word art and shapes(arrows).
Enter total from SC Grout Summary Table for Mix A Quantities shall include Offeror proposed slurry control grouting as well as any proposed interface treatment using grout in the slurry control grout holes. Offerors may also make assumptions on what mixes will be required for each hole, including not using some mixes at all. Provide a brief assumption/justification on when mix will need to be used and why.
0044AB
| ITEM: | DESCRIPTION: | OFFEROR: |
| 0044AB | GROUT MIX B |
| 0044AB, GROUT MIX B (Fill-In Quantity Only) | CF | |
| Brief Assumptions/Justifications: |
| W911WN-13-R-0002 | &"Times New Roman,Bold" CONTRACTOR PROPOSED |
| QUANTITIES BACKUP SHEET | &P of &N |
Enter Offeror Name Please provide quantity calculations for fill-in quantities ONLY. Format cells & add rows/columns as necessary. Delete word art and shapes(arrows).
Enter total from SC Grout Summary Table for Mix B Quantities shall include Offeror proposed slurry control grouting as well as any proposed interface treatment using grout in the slurry control grout holes. Offerors may also make assumptions on what mixes will be required for each hole, including not using some mixes at all. Provide a brief assumption/justification on when mix will need to be used and why.
0045AB
| ITEM: | DESCRIPTION: | OFFEROR: |
| 0045AB | GROUT MIX C |
| 0045AB, GROUT MIX C (Fill-In Quantity Only) | CF | |
| Brief Assumptions/Justifications: |
| W911WN-13-R-0002 | &"Times New Roman,Bold" CONTRACTOR PROPOSED |
| QUANTITIES BACKUP SHEET | &P of &N |
Enter Offeror Name Please provide quantity calculations for fill-in quantities ONLY. Format cells & add rows/columns as necessary. Delete word art and shapes(arrows).
Enter total from SC Grout Summary Table for Mix C Quantities shall include Offeror proposed slurry control grouting as well as any proposed interface treatment using grout in the slurry control grout holes. Offerors may also make assumptions on what mixes will be required for each hole, including not using some mixes at all. Provide a brief assumption/justification on when mix will need to be used and why.
0046AB
| ITEM: | DESCRIPTION: | OFFEROR: |
| 0046AB | GROUT MIX D |
| 0046AB, GROUT MIX D (Fill-In Quantity Only) | CF | |
| Brief Assumptions/Justifications: |
| W911WN-13-R-0002 | &"Times New Roman,Bold" CONTRACTOR PROPOSED |
| QUANTITIES BACKUP SHEET | &P of &N |
Enter Offeror Name Please provide quantity calculations for fill-in quantities ONLY. Format cells & add rows/columns as necessary. Delete word art and shapes(arrows).
Enter total from SC Grout Summary Table for Mix D Quantities shall include Offeror proposed slurry control grouting as well as any proposed interface treatment using grout in the slurry control grout holes. Offerors may also make assumptions on what mixes will be required for each hole, including not using some mixes at all. Provide a brief assumption/justification on when mix will need to be used and why.
0047AB
| ITEM: | DESCRIPTION: | OFFEROR: |
| 0047AB | GROUT MIX E1 - WITHOUT ANTIWASHOUT |
| 0047AB, GROUT MIX E1 (Fill-In Quantity Only) | CF | |
| Brief Assumptions/Justifications: |
| W911WN-13-R-0002 | &"Times New Roman,Bold" CONTRACTOR PROPOSED |
| QUANTITIES BACKUP SHEET | &P of &N |
Enter Offeror Name Please provide quantity calculations for fill-in quantities ONLY. Format cells & add rows/columns as necessary. Delete word art and shapes(arrows).
Enter total from SC Grout Summary Table for Mix E1 Quantities shall include Offeror proposed slurry control grouting as well as any proposed interface treatment using grout in the slurry control grout holes. Offerors may also make assumptions on what mixes will be required for each hole, including not using some mixes at all. Provide a brief assumption/justification on when mix will need to be used and why.
| ITEM: | DESCRIPTION: | OFFEROR: |
| 0048 | GROUT MIX E2 - WITH ANTIWASHOUT |
| 0048, GROUT MIX E2 (Fill-In Quantity Only) | CF | |
| Brief Assumptions/Justifications: |
| W911WN-13-R-0002 | &"Times New Roman,Bold" CONTRACTOR PROPOSED QUANTITIES |
| COMPUTATION SHEET | &P of &N |
Enter Offeror Name Please provide quantity calculations for fill-in quantities ONLY. Format cells & add rows/columns as necessary. Delete word art and shapes(arrows).
Enter total from SC Grout Summary Table for Mix E2 Quantities shall include Offeror proposed slurry control grouting as well as any proposed interface treatment using grout in the slurry control grout holes. Offerors may also make assumptions on what mixes will be required for each hole, including not using some mixes at all. Provide a brief assumption/justification on when mix will need to be used and why.
0049AB
| ITEM: | DESCRIPTION: | OFFEROR: |
| 0049AB | GROUT MIX F1 - SAND WITHOUT ANTIWASHOUT |
| 0049AB, GROUT MIX F1 (Fill-In Quantity Only) | CF | |
| Brief Assumptions/Justifications: |
| W911WN-13-R-0002 | &"Times New Roman,Bold" CONTRACTOR PROPOSED |
| QUANTITIES BACKUP SHEET | &P of &N |
Enter Offeror Name Please provide quantity calculations for fill-in quantities ONLY. Format cells & add rows/columns as necessary. Delete word art and shapes(arrows).
Enter total from SC Grout Summary Table for Mix F1 Quantities shall include Offeror proposed slurry control grouting as well as any proposed interface treatment using grout in the slurry control grout holes. Offerors may also make assumptions on what mixes will be required for each hole, including not using some mixes at all. Provide a brief assumption/justification on when mix will need to be used and why.
0050AB
| ITEM: | DESCRIPTION: | OFFEROR: |
| 50 | ERROR:#N/A |
| 0050, GROUT MIX F2 (Fill-In Quantity Only) | CF | |
| Brief Assumptions/Justifications: |
| W911WN-13-R-0002 | &"Times New Roman,Bold" CONTRACTOR PROPOSED |
| QUANTITIES BACKUP SHEET | &P of &N |
Enter Offeror Name Please provide quantity calculations for fill-in quantities ONLY. Format cells & add rows/columns as necessary. Delete word art and shapes(arrows).
Enter total from SC Grout Summary Table for Mix F2 Quantities shall include Offeror proposed slurry control grouting as well as any proposed interface treatment using grout in the slurry control grout holes. Offerors may also make assumptions on what mixes will be required for each hole, including not using some mixes at all. Provide a brief assumption/justification on when mix will need to be used and why.
SCG Verification Summary Table
| ITEM: | DESCRIPTION: | OFFEROR: |
| SUMMARY | SLURRY CONTROL GROUTING VERIFICATION HOLE SUMMARY TABLE |
| 0051AB | 0052AB | 0054AB | ||||
| STATION | TOP OF HOLE | TOP OF ROCK | BOTTOM OF HOLE | DRILLING & BACK-FILLING | CORING & BACK-FILLING | PRESSURE TESTS |
TOTALS
| W911WN-13-R-0002 | &"Times New Roman,Bold" CONTRACTOR PROPOSED |
| QUANTITIES BACKUP SHEET | &P of &N |
All Units in Feet Each Enter Offeror Name
0051AB
| ITEM: | DESCRIPTION: | OFFEROR: |
| 0051AB | DRILLING AND BACKFILLING, VERIFICATION HOLES, GROUTED ZONE |
0051AB, DRILLING & BACKFILLING, VERIF HOLES (Fill-In Quantity Only) FEET
| W911WN-13-R-0002 | &"Times New Roman,Bold" CONTRACTOR PROPOSED |
| QUANTITIES BACKUP SHEET | &P of &N |
Please provide quantity calculations for fill-in quantities ONLY. Format cells & add rows/columns as necessary. Delete word art and shapes(arrows).
Enter Offeror Name Enter total from SCG Verification Summary Table for Drilling and Backfilling, Verification Holes, Grouted Zone
0052AB
| ITEM: | DESCRIPTION: | OFFEROR: |
| 0052AB | CORE DRILLING AND BACKFILLING, VERIFICATION HOLES, GROUTED ZONE |
0052AB, CORE DRILLING & BACKFILLING, VERIF HOLES (Fill-In Quantity Only) FEET
| W911WN-13-R-0002 | &"Times New Roman,Bold" CONTRACTOR PROPOSED |
| QUANTITIES BACKUP SHEET | &P of &N |
Please provide quantity calculations for fill-in quantities ONLY. Format cells & add rows/columns as necessary. Delete word art and shapes(arrows).
Enter Offeror Name Enter total from SCG Verification Summary Table for Core Drilling and Backfilling, Verification Holes, Grouted Zone
0053AB
| ITEM: | DESCRIPTION: | OFFEROR: |
| 0053AB | OPTICAL TELEVIEWER SURVEYING, VERIFICATION HOLES, GROUTED ZONE |
| FROM 0052AB, CORE DRILLING & BACKFILLING, VERIF HOLES (Fill-In Quantity Only) | FEET | |
| x100% |
0053AB, OPTICAL TELE SURVEY, VERIF HOLES, GROUT ZONE (Fill-In Quant Only) FEET
| W911WN-13-R-0002 | &"Times New Roman,Bold" CONTRACTOR PROPOSED |
| QUANTITIES BACKUP SHEET | &P of &N |
Please provide quantity calculations for fill-in quantities ONLY. Format cells & add rows/columns as necessary. Delete word art and shapes(arrows).
Enter Offeror Name 100% of the rock coring quantity proposed as the fill-in quantity under 0052AB will be surveyed.
0054AB
| ITEM: | DESCRIPTION: | OFFEROR: |
| 0054AB | PRESSURE TESTING, VERIFICATION HOLES, GROUTED ZONE |
0054AB, PRESSURE TEST, VERIF HOLES, GROUT ZONE (Fill-In Quantity Only) EACH
| W911WN-13-R-0002 | &"Times New Roman,Bold" CONTRACTOR PROPOSED |
| QUANTITIES BACKUP SHEET | &P of &N |
Please provide quantity calculations for fill-in quantities ONLY. Format cells & add rows/columns as necessary. Delete word art and shapes(arrows).
Enter Offeror Name Enter total from SCG Verification Summary Table
0062AB
| ITEM: | DESCRIPTION: | OFFEROR: |
| 0062AB | ANTIWASHOUT ADMIXTURE FOR CUTOFF WALL |
| 0058 Cutoff Wall Construction in Bedrock, Non-Critical Areas (AA+AB) | 111,714 | SF | |
| 0061 Cutoff Wall Construction in Bedrock, Critical Areas (AA+AB) | + | 13,722 | SF |
| 15-Foot Zone Above Rock | + | 32,325 | SF |
| Minimum Effective Cutoff Wall Area Requiring Treatment | 157,761 | SF | |
| Based on the requirements in 03 37 29 CONCRETE FOR CUTOFF WALL. Effective is considered the area of the cutoff wall constructed in elevation view and does not consider overlaps. |
| Additional Effective Cutoff Wall Area Requiring Treatment In Critical Area | SF | |
| Assumptions & Calculations: |
| Actual Cutoff Wall Area Requiring Treatment (Including Overlaps) | SF | |||
| Assumptions & Calculations: | ||||
| Average Wall Thickness | FT | |||
| Assumptions & Calculations: | ||||
| Actual Volume of Concrete | CY | |||
| Assumptions & Calculations: | ||||
| Total Volume of Antiwashout Admixture (100 ounce per cubic yard) | GALLON | |||
| Assumptions & Calculations: | ||||
| Total Volume of Antiwashout Admixture (100 ounce per cubic yard) | GALLON | |||
| 0062AA, Antiwashout Admixture for Cutoff Wall, First | - | 8,237 | GALLON | |
| 0062AB, Antiwashout Admixture for Cutoff Wall, All Over | GALLON |
&10EAST BRANCH CUTOFF WALL
| W911WN-13-R-0002 | &"Times New Roman,Bold" CONTRACTOR PROPOSED |
| QUANTITIES BACKUP SHEET | &P of &N |
Please provide quantity calculations for fill-in quantities ONLY. Format cells & add rows/columns as necessary. Delete word art and shapes(arrows).
GENERAL: For line item 0062AB Offerors shall fill in their estimated quantity of Antiwashout Admixture required to fulfill the requirements in Section 03 37 29 CONCRETE FOR CUTOFF WALL. 0062AB shall be based on an assumed dosage rate of 100 ounces per cubic yard, minus the quantity provided for 0062AA.
In this area, discuss or list assumptions in regards to what the estimated ACTUAL area of cutoff wall area constructed will be. This should include what the element overlaps will be, and show calculations as to what the total increase in area is due to element overlaps. Quantity should NOT include quantities associated with entire element being below the lines shown on the drawings or any Contractor-proposed AWA above the required 15-foot specified in 03 37 29 as this will not be measured for payment. Provide actual cutoff wall area requiring treatment in SQUARE FEET in box above.
In this area, discuss or list assumptions in regards to what the average cutoff wall thickness is based on the proposed elements. Provide average wall thickness in FEET in box above.
In this area, calculate the actual volume of concrete based on the assumptions listed above. Include any addition assumptions as necessary. Provide volume in CUBIC YARDS in box above.
In this area, calculate the actual volume of antiwashout admixture required based on the calculated Actual Volume of Concrete and assuming a dosage rate of 100 ounces per cubic yard. Include any addition assumptions as necessary. Provide volume in GALLONS in box above.
If additional antiwashout admixture is required in the Critical Area based on the method-dependent requirements in 03 37 29, enter the effective area in the cell above and include any assumptions or calculations. If no additional antiwashout admixture is required, enter "0" (zero) in the cell above.
0079AB
| ITEM: | DESCRIPTION: | OFFEROR: |
| 0079AB | SINGLE-STAGE BACKFILLING AROUND CASING, GROUT HOLES |
BACKFILLING FOR SLURRY CONTROL GROUT HOLES (Fill-In Quantity Only) FEET
| x85% | ||
| 0079AB, SINGLE-STAGE BACKFILL AROUND CASING, GRT HLS (Fill-In Quant Only) | FEET |
| W911WN-13-R-0002 | &"Times New Roman,Bold" CONTRACTOR PROPOSED |
| QUANTITIES BACKUP SHEET | &P of &N |
Please provide quantity calculations for fill-in quantities ONLY. Format cells & add rows/columns as necessary. Delete word art and shapes(arrows).
Enter total for Backfilling from SC Grout Summary Table Assume 85% of backfilling around casing for slurry control grout holes will be single-stage backfilling.
Enter Offeror Name
0080AB
| ITEM: | DESCRIPTION: | OFFEROR: |
| 0080AB | MULTI-STAGE BACKFILLING AROUND CASING, GROUT HOLES |
BACKFILLING FOR SLURRY CONTROL GROUT HOLES (Fill-In Quantity Only) FEET
| x15% | ||
| 0080AB, MULTI-STAGE BACKFILL AROUND CASING, GRT HLS (Fill-In Quant Only) | FEET |
| W911WN-13-R-0002 | &"Times New Roman,Bold" CONTRACTOR PROPOSED |
| QUANTITIES BACKUP SHEET | &P of &N |
Please provide quantity calculations for fill-in quantities ONLY. Format cells & add rows/columns as necessary. Delete word art and shapes(arrows).
Enter total for Backfilling from SC Grout Summary Table Assume 15% of backfilling around casing for slurry control grout holes will be multi-stage backfilling.
Enter Offeror Name
0081AB
| ITEM: | DESCRIPTION: | OFFEROR: |
| 0081AB | RE-DRILLING, GROUT HOLES |
NUMBER OF SLURRY CONTROL GROUT HOLES PROPOSED EACH
| x17 | LF/EA | |
| RE-DRILLING FOR ZONE 1 (17 feet per hole) | LF |
| x5% | ||
| ASSUMED UNFORESEEN RE-DRILLS (5% of Slurry Control Grout Holes) | EACH |
| x10 | LF/EA | |
| RE-DRILLING FOR UNFORESEEN RE-DRILLS (10 feet for 5% of the holes) | LF |
0081AB, RE-DRILLING, GROUT HOLES (Fill-In Quantity Only) FEET
| W911WN-13-R-0002 | &"Times New Roman,Bold" CONTRACTOR PROPOSED |
| QUANTITIES BACKUP SHEET | &P of &N |
Enter Offeror Name Enter Proposed Number of Slurry Control Grout Holes shown on SC Grout Summary Table 17 Linear Feet of Re-Drilling will be measured and paid for on each Slurry Control Grout Hole for Zone 1. This cell should be the number of proposed holes times 17 linear feet.
All Offerors are to assume 5% of the Proposed Slurry Control Grout Holes will be re-drilled. This cell should be the number of proposed holes times 10 linear feet.
All Offerors are to assume unforeseen re-drills will result in 10 linear feet of re-drilling. This cell should be the number of unforeseen re-drills times 10 linear feet.
Please provide quantity calculations for fill-in quantities ONLY. Format cells & add rows/columns as necessary. Delete word art and shapes(arrows).
This cell should be the sum of the Re-Drilling for Zone 1, plus Re-Drilling for Unforeseen Re-Drills.
0082AB
| ITEM: | DESCRIPTION: | OFFEROR: |
| 0082AB | ADDITIONAL DRILLING AND GROUT HOLE SETUPS |
NUMBER OF SLURRY CONTROL GROUT HOLES PROPOSED EACH
| x5% | ||
| 0082AB, ADDITIONAL DRILLING AND GROUT HOLE SETUPS (Fill-In Quantity Only) | EACH |
| W911WN-13-R-0002 | &"Times New Roman,Bold" CONTRACTOR PROPOSED |
| QUANTITIES BACKUP SHEET | &P of &N |
Enter Offeror Name Enter Proposed Number of Slurry Control Grout Holes shown on SC Grout Summary Table All Offerors are to assume 5% of proposed slurry control grout holes will require additional setups.
Please provide quantity calculations for fill-in quantities ONLY. Format cells & add rows/columns as necessary. Delete word art and shapes(arrows).