Attachment_6_KDOT_standard_sheets_613_and_613a.pdf
PDF 489 KB Posted
- Attached to
- FT. Riley Road Maintenance
- Solicitation number
- W911RX-18-B-0003
About this file
Attachment 6: KDOT standard Sheets
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1� "
1 �"
3�"
4�"4�"2"
2"4�" 4�"
R
1� "
�" Tolerance3�"
Neutral axis1 �"
S y m m a b o u t
Lc
�" Tolerance
3�"
3�"
Neutral axis
S y m m a b o u t
Lc
�" R
" R
�" R
" R
�" R
4 �"3"
"7
4 �"
7 �"
2’-6"
2" 8"
1�"1�"
3"
1"
3"
2" Min.
2" Min.
1" Dia. hole
Transition Section
8 equal spaces 2 equal spaces 2 equal spaces
12’-6" Nested Thrie Beam 12’-6" Single Thrie Beam
31’-3" Adjacent to shoulder
6’-3" 6’-3" 6’-3" Post spacing6’-3"12’-6" Nested Thrie Beam
25’-0"
2 equal spaces
Variable Roadway
8" 6"
(4’-0" Minimum)
8" 8"
Roadway
�" min. to
2" max.
Variable
(4’-0" Minimum)
Normal W-Beam Guardrail
10°
GENERAL NOTE
SECTION A-A THRU RAIL ELEMENT
SECTION B-B THRU RAIL ELEMENT
TERMINAL CONNECTOR
ELEVATION
TRANSITION SECTION
TYPICAL THRIE BEAM
TYPICAL W-BEAM
RECTANGULAR WASHER
PARTIAL ELEVATION
PARTIAL PLAN
SECTION C-C (Steel Post) SECTION C-C (Wood Post)
Neutral axis on Terminal Connector only.
�"x2�" Post bolt slotted holes
1" Dia. holes
�" x1 �" Slotted holes
�" x 2�" Slotted hole
Rectangular washer to be used
�" Dia. hex nuts (5 req.)
Thrie Beam Terminal Connector
E .W .S
Transition Section
�" x1 �" Slotted holes
Bolts "A" wood or polymer block
6" x 8" x 18" Treated
W6x8.5 or W6x9
6"x8"x6’-6" Wood post
10d Galvanized nail (One per post to hold block)
Bolts "C"
13’-0" (4" Edge Curb)(Required)
13’-0" (4" Edge Curb)(Required)
Standard W-Beam Guardrail Thrie Beam Guardrail
�" Steel washer
7’-3�"
3’- 1�" 3’- 1�"
(Optional) x 6’-6" post
(From Thrie Beam to W-Beam rail) contractor has the option of providing wood or steel posts. See Standard Drawing RD611 for details.
Note: Guardrail is shown with wood posts. However the
A
A
A B
A B
B
B
C
C
(Other approved washer may be used.)
Optional �" x 1�" Slotted holes Rotated 50° (Typical) (12 req’d.)
Pay length
8" 1’-9"
8�"
10�"
4’-0"
8�"
" 2
2’-10�"
8"
Direction of traffic
Safety type bridge railÜ
ÙNested guardrail
PLAN VIEW
TO SAFETY SHAPE BRIDGE RAIL
GUARDRAIL ATTACHMENT
�" Dia. washers (5 req.)
Rectangular washers (5 req.)
�" Dia. x 14" hex head bolts (5 req.)
This Section is omitted for Std. Drawing RD607 and RD607A.
6"x8"x18" Treated wood or polymer block
6"x8"x21�" Block
Use galvanized 12 gauge steel rail elements unless otherwise noted.
Use galvanized anchor bolts and post rail fittings, see Standard Spec-ifications. Supply guard rail parts that are interchangeable with similar parts regardless of source or manufacturer.
Fabricate Terminal Connector from 10 gauge steel, see standard spec-ification. The connector has the same section as thrie beam guardrail
Terminal connector is subsidiary to the bid item "Steel Plate Guardrail".
Shop curve rails when radius is less than 150’.
Lap guardrail splices, including terminal connector, in the direction of traffic. Where traffic is temporarily carried in the opposite direction of final configuration, lap rail splices in the direction of permanent traffic.
Bridge to guardrail transition consists of 1- 25’-0" Thrie beam with
1- 12’-6" Thrie beam section nested in back of 25’-0" section (see layout), & 1- Thrie beam to W-beam Asymmetrical transition section. Use associated hardware with post spacing shown. Use w-beam guardrail with 6’-3" post spacing with rail furnished in 12’-6" or 25’-0" sections.
All material and work required for this installation are paid under the bid item "Steel Plate Guardrail".
STATE
KANSAS
YEARPROJECT N0.
SHEETS
TOTAL
SHEET NO.
rd .d g n rd
F il e
D ra w n B y b e rt
P lo tt e d -F
E B -2
:4
DATE REVISIONS BY APP’DNO.
KANSAS DEPARTMENT OF TRANSPORTATION
GUARDRAIL TRANSITION
DETAILS OF THRIE BEAM
01-05-04
07-02-09
12-06-10 J.O.B.
J.O.B.
J.O.B.
FHWA APPROVAL 1-1 1-1 1
DESIGNED
DETAILED
DESIGN CK. DETAIL CK. QUAN.CK.
RD613
TRACED Bowser
TRACE CK. King
QUANTITIES
S.W.K
S.W.K
S.W.K
Rev. Sec. C-C, notes & 28" rail height
Rev.Safety Shape Br. Rail detail
Added 4" Edge Curb, revised note
APP’D. James O. Brewer
K D
O T G r a p h ic s C e r ti fi e d
KDOT Graphics Certified 01-31-2011
Œ
1̂ "
1 ˜"
3‚"
R
1̂ "
ˆ" Tolerance3‰"
Neutral axis1 ˜"
Œ
Œ
S y m m a b o u t
Lc
ˆ" Tolerance
3‚"
3‰"
Neutral axis
S y m m a b o u t
Lc
•" R
" R
…" R
" R
•" R 1
4 ‚"3"
"7
4 ‚"
7 ‚"
2'-6"
2" 8"
1•"1•"
3"
1" ƒ
3"
1" Dia. hole
Variable Roadway
6"
(4'-0" Minimum)
10°
GENERAL NOTE
TERMINAL CONNECTOR
ELEVATION
TYPICAL THRIE BEAM
TYPICAL W-BEAM
RECTANGULAR WASHER
Neutral axis on Terminal Connector only.
ƒ"x2•" Post bolt slotted holes
1" Dia. holes ì ž" x1 „" Slotted holes
Rectangular washer to be used
‡" Dia. hex nuts (5 req.)
(Optional)
(From Thrie Beam to W-Beam rail)
(Other approved washer may be used.)
Optional ž" x 1ƒ" Slotted holes Rotated 50° (Typical) (12 req'd.)
4'-0"
8•"
" 2
2'-10‡"
8"
Direction of traffic
Safety type bridge railÜ
ÙNested guardrail
PLAN VIEW
TO SAFETY SHAPE BRIDGE RAIL
GUARDRAIL ATTACHMENT
‡" Dia. washers (5 req.)
Rectangular washers (5 req.)
‡" Dia. x 14" hex head bolts (5 req.)
(MGS) GUARDRAIL TRANSITION
DETAILS OF THRIE BEAM to
4‚"4‚"2" 2"4‚" 4‚"
2" Min.
2" Min.
ƒ" x 2•" Slotted hole
7'-3•"
3'- 1•" 3'- 1•"A
A
B
B
12•" 5'- 2•"
ASYMMETRICAL TRANSITION SECTION
SECTION A-A
THRU RAIL ELEMENT
SECTION B-B
THRU RAIL ELEMENT
(No bolt
Bolt "D"
1" 6"
4"
1ƒ
12"
25'-0" Adjacent to shoulder
PARTIAL ELEVATION
PARTIAL PLAN
E .W .S
Transition Section
13'-0" (4" Edge Curb)(Required)
13'-0" (4" Edge Curb)(Required)
Thrie Beam Guardrail
A B
A BC
C
Pay length
8" 1'-9"
8‚"
18'-9" Thrie Beam section
W-Beam Guardrail (MGS)
3'-1•" spacing
6"x12"x19" Blockout
6'-3" spacing
No bolt
Bolt "D" (Steel Post)
T e r m in a l
C o n n e c to r
T h r ie
B e a m
6'-0" posts with 6"x12"x14" blockouts
12'-6" Nested (12 ga.) Thrie Beam Single (12 ga.)
Thrie Beam
@ 3'-1•" spacing
6"x8"x19" blockouts
7'-0" posts with 1'-6ƒ" spacing
W-Beam (12 ga.) Guardrail (MGS height)
6'-0" posts with 6"x12"x19" blockouts
6"x12"x19" Blockout if 2 holes)
Treated wood or polymer block
Note: All holes ƒ" dia.
SECTION C-C (BLOCKOUTS)
Thrie Beam Guardrail
6"x8"x19" Blockout
12"
1-25-12 S.W.K. J.O.B.
STATE
KANSAS
YEARPROJECT N0.
SHEETS
TOTAL
SHEET NO.
rd a .d g n
F il e
D ra w n B y tr h o a d s
P lo tt e d -A
P R -2
:4
DATE REVISIONS BY APP'DNO.
KANSAS DEPARTMENT OF TRANSPORTATION
FHWA APPROVAL
DESIGNED
DETAILED
DESIGN CK. DETAIL CK. QUAN.CK.
RD613A
TRACED
TRACE CK.
QUANTITIES
APP'D.
Revised Details, Thrie-Beam
Midspan Guardrail splice Midspan Guardrail splice
W6x8.5 or W6x9 x 6'-0" post
(10 ga.)
Transition Section
Nested W-Beam Guardrail (MGS)
(12 ga.)
Nested W-Beam Guardrail
Treated Wood or
Polymer Blockout
2-10-16 T.T.R. S.W.K.
SCOTT W. KING
8" 12"
(STEEL POST)
SECTION C-C
(WOOD POST)
SECTION C-C
Variable Roadway
(4'-0" Minimum)
Nail
16d Galv.
Bolt "D"
(No bolt if 2 holes)
Treated Wood Post
6" X 8" X 6'-0"
Added Detail, Wood Post
Holes ì ž" x 1„" Slotted the bid item "Guardrail, Steel Plate (MGS)".
All material and work required for this construction is Subsidiary to
(MGS) guardrail run.
ation use (MGS) W-beam guardrail with only one post type used within hardware with post sizes and location shown. For the remainder of install-
1- Thrie beam to W-beam Asymmetrical transition section, use associated
1- 12'-6" thrie-beam section nested in back of 18'-9" section (See Layout), Bridge to guardrail transition consists of 1- 18'-9" thrie-beam with final configuration, lap rail splices in the direction of permanent traffic.
traffic. Where traffic is temporarily carried in the opposite direction of
Lap guardrail splices, including terminal connector, in the direction of
Shop bend curve rails when radius is less than 150'.
Steel Plate (MGS)".
guardrail. Terminal connector is Subsidiary to the bid item "Guardrail, Specification. The connector has the same section as thrie beam
Fabricate Terminal Connector from 10 gauge steel, see Standard installation.
guardrail end terminal may be independent from the remainder of the the w-beam installation. The blockout size and material used in the with wood or composite blockouts used throughout the remainder of
Wood blockouts may be used through the 25'-0" thrie-beam section parts regardless of source or manufacturer.
ifications. Supply guardrail parts that are interchangeable with similar
Use galvanized anchor bolts and post rail fittings, see Standard Spec-
Use galvanized 12 gauge steel rail elements unless otherwise noted.
Drawing RD611A and RD611B for details.
Use approved wood or steel posts (steel posts shown). See Standard
Use Steel or Wood Posts (Steel Posts Shown)
4-21-16
K D
O T G r a p h ic s C e r ti fi e d
KDOT Graphics Certified 04-25-2016
File details come from the government source that posted it.