This is a detailed Bill of Quantity (BOQ) for an Indoor Firing Range renovation project, organized into eight divisions: Sitework, Metals, Thermal and Moisture Protection, Doors and Windows, Finishes, Specialties, Mechanical, and Electrical. The document outlines specific quantities and materials needed for renovation work including 4,800 M2 of asphalt work, repairs to roofing systems, door modifications (32 doors total), interior/exterior finishes, bullet-proof protection installations, plumbing fixtures, HVAC systems (including multiple exhaust fans and air conditioning units), and electrical work including power supply installations and fire detection systems.
The BOQ is associated with Department of Army solicitation W519TC25RA003 at Rock Island Arsenal and includes specialized items specific to firing range requirements such as bullet-proof door protection, wall protection, and ceiling protection. Notable technical requirements include installation of fire alarm systems, IP telephone systems, public address systems with microphones and loudspeakers, and comprehensive HVAC modifications including multiple exhaust fans ranging from 53 to 8,320 liters per second capacity. The document serves as a detailed quantification of materials and work required but does not include pricing information in the version provided.
View the file
Other files
Show all 30
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Cover Sheet
| BILL NO. (IFR) | |
| INDOOR FIRING RANGE |
Bill-IFR
| ITEM | DESCRIPTION | QTY | UNIT | RATE | AMOUNT SR |
| DIVISION 1 - SITEWORK | |||||
| ASPHALT WORK | |||||
| 1 | Checking the existing subgrade level, and adjusting leves if required, including compaction works to minimum 95% modified proctor test. | 4,800 | M2 | ||
| 2 | 200 mm thick granular base course, MDD>100%, CBR>80% | 4,800 | M2 | ||
| 3 | Bituminous Prime coat (MC-1) | 4,800 | M2 | ||
| 4 | 70 mm thick bituminous base course . | 4,800 | M2 | ||
| To Bill Summary | SR | ||||
| DIVISION 2 - METALS | |||||
| HANDRAIL AND BLUSTER (FOR EXTERNAL STEPS) | |||||
| galvanized pipe handrail and bluster 50 mm diameter, painted metal flange including fixings and finishings complete as per drawings and specifications | |||||
| 5 | handrail 300 mm high, To suit entrance steps | 9 | LM | ||
| To Bill Summary | SR | ||||
| DIVISION 3 - THERMAL AND MOISTURE PROTECTION | |||||
| WATERPROOFING, DAMP PROOFING AND MOISTURE PROTECTION | |||||
| Damp-proofing | |||||
| 6 | Bituminous damp-proofing courses to concrete surfaces in direct contact with soil | 20 | M² | ||
| ROOFING SYSTEM | |||||
| leak test then to remove the damaged area to provide the roofing system comprising gravel layer 50 mm thick, separation sheet, 50 mm thick rigid thermal insulation, 2-layer waterproofing membrane,4mm thick each layer 400x400x40 mm thick precast concrete tiles (where required). 50 mm minimum thickness of concrete screed to form slopes to drain including forming cant strips, waterproofing membrane metal base flashings, sheet metal flashings, sealants and the like complete as per drawings and specifications | |||||
| 7 | To suit roof area | 20 | M² | ||
| To Bill Summary | SR | ||||
| DIVISION 4 - DOORS AND WINDOWS | |||||
| DOOR SETS | |||||
| Touch up paint for the following metal doors | |||||
| 8 | Single leaf door, leaf size 950 x 2100 mm | 13 | No | ||
| 9 | Double leaves door , leaf size 950 x 2100 mm | 19 | No | ||
| To Bill Summary | SR | ||||
| DIVISION 5 - FINISHES | |||||
| INTERNAL FINISHES | |||||
| Finishings: Floors | |||||
| 10 | Remove the damaged Porcelain tiles & re install with the size of 400x400x9mm, fixed on concrete mortar with pointing between tiles | 20 | M² | ||
| 11 | Remove the damaged Ceramic tiles & re install with the size of 200x200x9mm, fixed on concrete glue with pointing between tiles | 10 | M² | ||
| 12 | Code F04, plain trowelled concrete with epoxy paint hardener on the damaged application | 1.2 | M² | ||
| Finishings: Ceilings | |||||
| 13 | Code C01, 600x600x19 mm thick Suspended ceiling panels to be replaced | 20 | M² | ||
| 14 | Code C09, 600*600*0.5 mm thick perforated metalic painted panels to be replaced | 5 | M² | ||
| 15 | Code C03, Re-Paint system to exposed structure surface | 30 | M² | ||
| Finishings: Walls | |||||
| 16 | Remove the damaged Ceramic tiles & re install with the size of 200x200x8mm including backing mortar and pointing in colored grout | 20 | M² | ||
| 17 | Code W01, re-paint system | 40 | M² | ||
| EXTERNAL FINISHES | |||||
| Finishings: Floors | |||||
| 18 | Remove the damaged Porcelain tiles & re install with the size of 400x400x9mm, fixed on concrete mortar with pointing between tiles | 20 | M² | ||
| 19 | Porcelain Treads, one piece (replace the damaged) | 2 | LM | ||
| 20 | Porcelain Risers, one piece (replace the damaged) | 2 | LM | ||
| Finishings: Ceilings | |||||
| 21 | Code C06, re-paint system | 4 | M² | ||
| Finishings: Walls | |||||
| 22 | re-Paint system | 23 | M² | ||
| 23 | re-Paint system to concrete surface with internal roof parapet | 100 | M² | ||
| ( Note: The Matching skirts cost is included in the Unit rates of respective flooring) | |||||
| To Collection | SR | ||||
| DIVISION 6 - SPECIALTIES | |||||
| TOILET AND BATH ACCESSORIES | |||||
| Supply and install the following toilet and bath accessories as per selection schedule including fixings and trims as per specifications and drawings G-A605 to suit locations as required | |||||
| 24 | Ref. FM1, clear glass mirror with stainless steel frame size 450 x 750 mm | 3 | No | ||
| 25 | Ref. PTD, surface mounted stainless steel, paper towel dispenser | 1 | No | ||
| 26 | Ref. RH, robe hook | 3 | No | ||
| 27 | Ref. SD, liquid soap dispenser | 2 | No | ||
| 28 | Ref. PH, toilet paper holder | 3 | No | ||
| 29 | Ref. HS, hand spray | 3 | No | ||
| 30 | Ref. WR, waste receptacle | 4 | No | ||
| INTERNAL SINAGE | |||||
| Internal signage as per drawing I005-N101 and interior design specifications | |||||
| 31 | Type S1 Typical room sign | 20 | No. | ||
| 32 | Type S3 Picture sign (Pictograms) | 10 | No. | ||
| 33 | Type S8 Illuminated fire exit sign | 4 | No. | ||
| IFR SPECIALIST WORKS | |||||
| A | Doors bullet proof protection | - | LS | ||
| B | Wall bullet proof protection | - | LS | ||
| C | Bullet proof reflected ceiling | - | LS | ||
| D | Termination of control equipment | - | LS | ||
| E | Testing & commissioning | - | LS | ||
| To Bill Summary | SR | ||||
| DIVISION 07 - MECHANICAL | |||||
| PLUMBING INSTALLATION | |||||
| Supply and install sanitary fixtures including necessary fittings and accessories as per drawings and specifications. | |||||
| 34 | Perineal spray with vaccum breaker. | 8 | No | ||
| 35 | Roof vent 75 mm dia. Including flashings, anchors and trims as required. | 4 | No | ||
| 36 | PACU condensate drain . | 1 | Item | ||
| Portable fire extinguisher | No | ||||
| 37 | Multipurpose type ABC portable fire extinguisher 4.5kg capacity, EF-1 | 4 | No | ||
| 38 | Multipurpose type ABC Mobile fire extinguisher 50kgs capacity, EF-3 | 1 | No | ||
| Mini-split type air conditioning units as per drawings and specifications. | |||||
| 39 | FCU-1 / ACCU-1 (heatng & cooling), capacity 8.8 KW | 1 | NO | ||
| 40 | FCU-2 / ACCU-2 (heatng & cooling), capacity 10.5 KW | 1 | NO | ||
| 41 | FCU-3 / ACCU-3 (heatng & cooling), capacity 3.5 KW | 1 | NO | ||
| Exhaust fans wall mounted as per drawings and specifications. | |||||
| 42 | EF-4, 279 liter per second capacity. | 1 | NO | ||
| 43 | EF-5, 371 liter per second capacity. | 1 | No | ||
| 44 | EF-7, 53 liter per second capacity. | 1 | No | ||
| 45 | EF-10, 231 liter per second capacity. | 1 | NO | ||
| 46 | EF-12, 231 liter per second capacity. | 1 | No | ||
| Exhaust fans roof mounted as per drawings and specifications. | |||||
| 47 | Ref. EF-6, 8320 liter per second capacity. | 6 | NO | ||
| 48 | Ref. EF-8, 352 liter per second capacity. | 1 | NO | ||
| 49 | Ref. EF-9, 212 liter per second capacity | 1 | No | ||
| To Collection | SR | ||||
| DIVISION 07 - MECHANICAL | |||||
| Exhaust fans roof mounted as per drawings and specifications. | |||||
| 50 | |||||
| Ref. EF-11, 151 liter per second capacity. | 1 | No | |||
| Galvanized sheet steel (G90) ductwork including fittings, dampers, sound attenuators air diffusers, grills, filters, hepa filters ,insulation cladding and support system as per (SMACNA) requirements and drawings & specifications | 1 | Item | |||
| 51 | Door louvers size 400X250mm | 2 | NO | ||
| 52 | Door louvers size 450X250mm | 1 | No | ||
| 53 | Door louvers size 500X250mm | 2 | NO | ||
| 54 | Door louvers size 250X250mm | 1 | NO. | ||
| To Collection | SR | ||||
| DIVISION 08 - ELECTRICAL | |||||
| INCOMING POWER SUPPLY INSTALLATION | |||||
| Supply, install, test & commission sub-main circuit: 600/1000V XLPE multi-core copper cable in conduits or on cable tray (measured separately) including tapes, conductors, junction boxes, connection for feeders and various power loads for complete installation as per project drawings and technical specifications | |||||
| 55 | Cable 3(4x300) mm²+120 mm² (grounding) | 10 | M | ||
| 56 | Cable (4x240) mm²+120 mm² (grounding) | 100 | M | ||
| 57 | Cable (4x120) mm²+70 mm² (grounding) | 130 | M | ||
| 58 | Cable (4x70) mm²+35 mm² (grounding) | 10 | M | ||
| 59 | Cable (4x50) mm²+25 mm² (grounding) | 25 | M | ||
| 60 | Cable (4x16) mm²+16 mm² (grounding) | 50 | M | ||
| POWER AND LIGHTING INSTALLATION | |||||
| Supply, install, test & commission power and lighting accessories including all necessary boxes, plates, pipes, wires, cable trays, switches, sockets and as required seal enclosures as per project drawings and technical specifications | |||||
| 61 | Disconnect switch, 2P non-fused, 20A, 2p, 250V for EWH | 5 | No | ||
| 62 | Disconnect switch, 2P non-fused, 20A, 2P, 250V for EF | 3 | No | ||
| 63 | Disconnect switch, non-fused, 30A, 3P, 660V for ACCU / FCU (weatherproof) | 6 | No | ||
| 64 | Disconnect switch, non-fused, 30A, 3P, 660V for EF (weatherproof) | 9 | No | ||
| 65 | Disconnect switch, non-fused, 300A, 3P, 660V for (PAU) | 4 | No | ||
| To Collection | SR | ||||
| DIVISION 08 - ELECTRICAL | |||||
| POWER AND LIGHTING INSTALLATION | |||||
| Supply, install, test & commission power and lighting accessories including all necessary boxes, plates, pipes, wires, cable trays, switches, sockets and as required seal enclosures as per project drawings and technical specifications | |||||
| 66 | Single socket outlet, 13A, 250V grounding type | 2 | No | ||
| 67 | Single socket outlet, 13A, 250V weatherproof grounding type | 7 | No | ||
| 68 | Double socket outlet, 13A, 250V weatherproof grounding type wall mounted. | 24 | No | ||
| 69 | Double socket outlet, 13A, 250V grounding type wall mounted at 15 cm from top of counter level. | 18 | No | ||
| Supply, install, test & commission Lighting fixtures complete with luminaries, ceiling roses, heat resisting flexible cables switches and mounting accessories as per project drawings and technical specifications | |||||
| 70 | Ref. C | 64 | No | ||
| 71 | Ref. F4 | 8 | No | ||
| 72 | Ref. F4(EMERGENCY) | 2 | No | ||
| 73 | Ref.M5 | 205 | No | ||
| To Collection | SR | ||||
| DIVISION 08 - ELECTRICAL | |||||
| Supply, install, test & commission Lighting and power panelboards including circuit breakers, grounding, fixings, markers and directory required for complete installation as per project drawings and technical specifications | |||||
| 74 | Ref. MDP | 1 | No | ||
| 75 | Ref.MPC | 1 | No | ||
| 76 | Ref. LPP | 1 | No | ||
| 77 | Ref. SDP | 1 | No | ||
| 78 | Ref. DPEF | 1 | No | ||
| 79 | Ref. PPFR | 1 | No | ||
| FIRE DETECTION AND ALARM SYSTEM INSTALLATION | |||||
| Supply, install, test & commission fire detection and alarm system comprising optical type smoke detector, heat detector, optical smoke detector duct mounted, fire alarm control panel (FACP), alarm bells, manual stations and twisted fire resistant shielded cable including all zone wiring via 2 x 1.5 mm² cu-micc fire alarm cables in 20 mm dia PVC conduits as per project drawings and technical specifications, fire alarm panel should include power source, rechargeable battery, battery charger for a network consists of: | |||||
| 80 | Fire alarm control panel (2-zone), addressable type | 1 | No | ||
| 81 | Optical smoke detector ceiling mounted | 4 | No | ||
| 82 | Heat detector | 1 | No | ||
| 83 | Fire alarm bell with flasher. | 1 | No | ||
| 84 | Interface unit with AC system on the roof. | 1 | No | ||
| To Collection | SR | ||||
| IP- TELEPHONE SYSTEM | |||||
| Supply, install, test & commission complete IP- telephone system including equipment, devices, cable, conduit, boxes, and other accessories deemed necessary, complete as per drawings and signal corps specifications | |||||
| UTP cat 6 patch cable 25 cm long | 8 | No | |||
| UTP cat-6 drop cable 3.0 m long. | 8 | No | |||
| SC-LC fiber optics patch panel, 12 ports. | 1 | No | |||
| COMPUTER SYSTEM | |||||
| Supply, install, test & commission complete computer system comprising of computer cabinets, fittings and ports as per technical specifications and drawings | |||||
| Connection cable between patch panel and network distributor, UTP Cat6 Patch cable, 25 cm long | 8 | No | |||
| Network point including fittings/conduiting from network receptacle until communication cabinet, copper wires (UTP Cat6 cables) | 8 | No | |||
| Connection cable between network port and computer (UTP Cat6 Drop cable) 3m long | 8 | No | |||
| Fiber optics Patch Panel (Single Mode FO) including 12 nos. fiber optic connections, type SC | 1 | No | |||
| Network distributer, 24 ports, RJ-45, speed 10/100 Mbps | 1 | No | |||
| Fiber optics port for network distributer, LX type | 1 | No | |||
| To Collection | |||||
| PUBLIC ADDRESS SYSTEM INSTALLATION | |||||
| Allow for the supply and installation of a complete three zone public address system comprising microphones and loudspeakers,including pull boxes, wiring, cabling,necessary fittings, supports and connections to buildings sound system comprising 120 w power amplifiers, (graphic equalizer,feedback suppresser, mixer frame) all as shown on drawings and as described in specification | |||||
| Loudspeaker, ceiling mounted 6w | 10 | No | |||
| Microphone outlet | 2 | No | |||
| Microphone set with stand desk type | 2 | No | |||
| 120 W power amplifier | 1 | No | |||
| Ground system equipment rack 16U at control room, ( G008 ) with fans, power strip 6 outlets and all related access, necessary fittings, supports and connections. | 1 | No | |||
| To Collection | SR |
&L&"Arial,Bold"BILL NO. IFR
&C&"Times New Roman,Bold"&11&U INDOOR FIRING RANGE&R&"Arial,Bold"SITE 2 C &C&"Arial,Bold" IFR-&P / &[Pages
Bill Summary
| ITEM | DESCRIPTION | AMOUNT SR | |
| BILL SUMMARY | |||
| Sheet -1 | SITEWORK | ||
| Sheet -2 | METALS | ||
| Sheet -3 | THERMAL AND MOISTURE PROTECTION | ||
| Sheet -4 | DOORS AND WINDOWS | ||
| Sheet -5 | FINISHES | ||
| Sheet -6 | SPECIALITIES | ||
| Sheet -7 | MECHANICAL | ||
| Sheet -9 | ELECTRICAL | ||
| To Tender Summary SR |