Attachment 0013 Bill of Quantity IFR 2020.xls

XLS spreadsheet 87 KB Posted

Attached to
Renovation of Indoor Firing Range
Solicitation number
W519TC25RA003
Issued by

About this file

This is a detailed Bill of Quantity (BOQ) for an Indoor Firing Range renovation project, organized into eight divisions: Sitework, Metals, Thermal and Moisture Protection, Doors and Windows, Finishes, Specialties, Mechanical, and Electrical. The document outlines specific quantities and materials needed for renovation work including 4,800 M2 of asphalt work, repairs to roofing systems, door modifications (32 doors total), interior/exterior finishes, bullet-proof protection installations, plumbing fixtures, HVAC systems (including multiple exhaust fans and air conditioning units), and electrical work including power supply installations and fire detection systems.

The BOQ is associated with Department of Army solicitation W519TC25RA003 at Rock Island Arsenal and includes specialized items specific to firing range requirements such as bullet-proof door protection, wall protection, and ceiling protection. Notable technical requirements include installation of fire alarm systems, IP telephone systems, public address systems with microphones and loudspeakers, and comprehensive HVAC modifications including multiple exhaust fans ranging from 53 to 8,320 liters per second capacity. The document serves as a detailed quantification of materials and work required but does not include pricing information in the version provided.

View the file

Other files

File Type Posted
Solicitation Amendment 0001-0005 W519TC25RA0030004 CONFORMED.pdf PDF
Attachment 0020 Question and Answers IFR Amendment 0004_26 February 2025.pdf PDF
W519TC25RA0030004_Conformed Copy.pdf PDF
Solicitation Amendment - W519TC25RA0030003_CONFORMED COPY.pdf PDF
Attachment 0011 Section M dated 10 February 2025.pdf PDF
Attachment 0017 Change Orders IFR_Redacted.pdf PDF
Solicitation Amendment - W519TC25RA0030003_CONFORMED COPY.pdf PDF
Attachment 0010 Section L dated 10 February 2025.pdf PDF
Attachment 0016 Questions and Answers received via email prior to 11 December 2024.pdf PDF
Attachment 0018 Supplementary Reference IFR Specifications Book.pdf PDF
Attachment 0001 IFR Scope of Work 06 February 2025.pdf PDF
Attachment 0019 Historical Quantities Proposal QTN 18.12.21-Rev01-Discounted dtd 27.01.2022 AAS (1)_Redacted.pdf PDF
Solicitation Amendment W519TC25RA0030002 SF 30.pdf PDF
ATTACHMENT 0012 BREAKDOWN OF CLINS.xlsx XLSX spreadsheet
Attachment 0010 Section L dated 06 December 2024.pdf PDF
Attachment 0015- Final Structural Report - IFR.pdf PDF
Solicitation Amendment W519TC25RA0030001 SF 30.pdf PDF
Attachment 0014 Questions and Answers received from Industry Day and Site visit 03-04 December 2024.pdf PDF
Attachment 0002 - Pricing Matrix.xlsx XLSX spreadsheet
Attachment 0001 - Indoor Firing Range SOW.pdf PDF
Attachment 0007 - IFR Inspection Plan.pdf PDF
Solicitation - W519TC25RA003.pdf PDF
Attachment 0010 - Section L.pdf PDF
Attachment 0011 - Section M.pdf PDF
Attachment 0003 Bid Bond SF24-23a.pdf PDF
Attachment 0006 - Drawings and Specifications.zip ZIP file
Attachment 0004 Surety Bond SF28-23a.pdf PDF
Attachment 0008 QASP IFR 11-13-2024.pdf PDF
Attachment 0009 - Past Performance Questionaire.pdf PDF
Attachment 0005 - Requirements for Access to MNG Base OPM-SANG.pptx PPTX presentation
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Cover Sheet

BILL NO. (IFR)
INDOOR FIRING RANGE

Bill-IFR

ITEMDESCRIPTIONQTYUNITRATEAMOUNT SR
DIVISION 1 - SITEWORK
ASPHALT WORK
1Checking the existing subgrade level, and adjusting leves if required, including compaction works to minimum 95% modified proctor test.4,800M2
2200 mm thick granular base course, MDD>100%, CBR>80%4,800M2
3Bituminous Prime coat (MC-1)4,800M2
470 mm thick bituminous base course .4,800M2
To Bill SummarySR
DIVISION 2 - METALS
HANDRAIL AND BLUSTER (FOR EXTERNAL STEPS)
galvanized pipe handrail and bluster 50 mm diameter, painted metal flange including fixings and finishings complete as per drawings and specifications
5handrail 300 mm high, To suit entrance steps9LM
To Bill SummarySR
DIVISION 3 - THERMAL AND MOISTURE PROTECTION
WATERPROOFING, DAMP PROOFING AND MOISTURE PROTECTION
Damp-proofing
6Bituminous damp-proofing courses to concrete surfaces in direct contact with soil20M²
ROOFING SYSTEM
leak test then to remove the damaged area to provide the roofing system comprising gravel layer 50 mm thick, separation sheet, 50 mm thick rigid thermal insulation, 2-layer waterproofing membrane,4mm thick each layer 400x400x40 mm thick precast concrete tiles (where required). 50 mm minimum thickness of concrete screed to form slopes to drain including forming cant strips, waterproofing membrane metal base flashings, sheet metal flashings, sealants and the like complete as per drawings and specifications
7To suit roof area20M²
To Bill SummarySR
DIVISION 4 - DOORS AND WINDOWS
DOOR SETS
Touch up paint for the following metal doors
8Single leaf door, leaf size 950 x 2100 mm13No
9Double leaves door , leaf size 950 x 2100 mm19No
To Bill SummarySR
DIVISION 5 - FINISHES
INTERNAL FINISHES
Finishings: Floors
10Remove the damaged Porcelain tiles & re install with the size of 400x400x9mm, fixed on concrete mortar with pointing between tiles20M²
11Remove the damaged Ceramic tiles & re install with the size of 200x200x9mm, fixed on concrete glue with pointing between tiles10M²
12Code F04, plain trowelled concrete with epoxy paint hardener on the damaged application1.2M²
Finishings: Ceilings
13Code C01, 600x600x19 mm thick Suspended ceiling panels to be replaced20M²
14Code C09, 600*600*0.5 mm thick perforated metalic painted panels to be replaced5M²
15Code C03, Re-Paint system to exposed structure surface30M²
Finishings: Walls
16Remove the damaged Ceramic tiles & re install with the size of 200x200x8mm including backing mortar and pointing in colored grout20M²
17Code W01, re-paint system40M²
EXTERNAL FINISHES
Finishings: Floors
18Remove the damaged Porcelain tiles & re install with the size of 400x400x9mm, fixed on concrete mortar with pointing between tiles20M²
19Porcelain Treads, one piece (replace the damaged)2LM
20Porcelain Risers, one piece (replace the damaged)2LM
Finishings: Ceilings
21Code C06, re-paint system4M²
Finishings: Walls
22re-Paint system23M²
23re-Paint system to concrete surface with internal roof parapet100M²
( Note: The Matching skirts cost is included in the Unit rates of respective flooring)
To CollectionSR
DIVISION 6 - SPECIALTIES
TOILET AND BATH ACCESSORIES
Supply and install the following toilet and bath accessories as per selection schedule including fixings and trims as per specifications and drawings G-A605 to suit locations as required
24Ref. FM1, clear glass mirror with stainless steel frame size 450 x 750 mm3No
25Ref. PTD, surface mounted stainless steel, paper towel dispenser1No
26Ref. RH, robe hook3No
27Ref. SD, liquid soap dispenser2No
28Ref. PH, toilet paper holder3No
29Ref. HS, hand spray3No
30Ref. WR, waste receptacle4No
INTERNAL SINAGE
Internal signage as per drawing I005-N101 and interior design specifications
31Type S1 Typical room sign20No.
32Type S3 Picture sign (Pictograms)10No.
33Type S8 Illuminated fire exit sign4No.
IFR SPECIALIST WORKS
ADoors bullet proof protection-LS
BWall bullet proof protection-LS
CBullet proof reflected ceiling-LS
DTermination of control equipment-LS
ETesting & commissioning-LS
To Bill SummarySR
DIVISION 07 - MECHANICAL
PLUMBING INSTALLATION
Supply and install sanitary fixtures including necessary fittings and accessories as per drawings and specifications.
34Perineal spray with vaccum breaker.8No
35Roof vent 75 mm dia. Including flashings, anchors and trims as required.4No
36PACU condensate drain .1Item
Portable fire extinguisherNo
37Multipurpose type ABC portable fire extinguisher 4.5kg capacity, EF-14No
38Multipurpose type ABC Mobile fire extinguisher 50kgs capacity, EF-31No
Mini-split type air conditioning units as per drawings and specifications.
39FCU-1 / ACCU-1 (heatng & cooling), capacity 8.8 KW1NO
40FCU-2 / ACCU-2 (heatng & cooling), capacity 10.5 KW1NO
41FCU-3 / ACCU-3 (heatng & cooling), capacity 3.5 KW1NO
Exhaust fans wall mounted as per drawings and specifications.
42EF-4, 279 liter per second capacity.1NO
43EF-5, 371 liter per second capacity.1No
44EF-7, 53 liter per second capacity.1No
45EF-10, 231 liter per second capacity.1NO
46EF-12, 231 liter per second capacity.1No
Exhaust fans roof mounted as per drawings and specifications.
47Ref. EF-6, 8320 liter per second capacity.6NO
48Ref. EF-8, 352 liter per second capacity.1NO
49Ref. EF-9, 212 liter per second capacity1No
To CollectionSR
DIVISION 07 - MECHANICAL
Exhaust fans roof mounted as per drawings and specifications.
50
Ref. EF-11, 151 liter per second capacity.1No
Galvanized sheet steel (G90) ductwork including fittings, dampers, sound attenuators air diffusers, grills, filters, hepa filters ,insulation cladding and support system as per (SMACNA) requirements and drawings & specifications1Item
51Door louvers size 400X250mm2NO
52Door louvers size 450X250mm1No
53Door louvers size 500X250mm2NO
54Door louvers size 250X250mm1NO.
To CollectionSR
DIVISION 08 - ELECTRICAL
INCOMING POWER SUPPLY INSTALLATION
Supply, install, test & commission sub-main circuit: 600/1000V XLPE multi-core copper cable in conduits or on cable tray (measured separately) including tapes, conductors, junction boxes, connection for feeders and various power loads for complete installation as per project drawings and technical specifications
55Cable 3(4x300) mm²+120 mm² (grounding)10M
56Cable (4x240) mm²+120 mm² (grounding)100M
57Cable (4x120) mm²+70 mm² (grounding)130M
58Cable (4x70) mm²+35 mm² (grounding)10M
59Cable (4x50) mm²+25 mm² (grounding)25M
60Cable (4x16) mm²+16 mm² (grounding)50M
POWER AND LIGHTING INSTALLATION
Supply, install, test & commission power and lighting accessories including all necessary boxes, plates, pipes, wires, cable trays, switches, sockets and as required seal enclosures as per project drawings and technical specifications
61Disconnect switch, 2P non-fused, 20A, 2p, 250V for EWH5No
62Disconnect switch, 2P non-fused, 20A, 2P, 250V for EF3No
63Disconnect switch, non-fused, 30A, 3P, 660V for ACCU / FCU (weatherproof)6No
64Disconnect switch, non-fused, 30A, 3P, 660V for EF (weatherproof)9No
65Disconnect switch, non-fused, 300A, 3P, 660V for (PAU)4No
To CollectionSR
DIVISION 08 - ELECTRICAL
POWER AND LIGHTING INSTALLATION
Supply, install, test & commission power and lighting accessories including all necessary boxes, plates, pipes, wires, cable trays, switches, sockets and as required seal enclosures as per project drawings and technical specifications
66Single socket outlet, 13A, 250V grounding type2No
67Single socket outlet, 13A, 250V weatherproof grounding type7No
68Double socket outlet, 13A, 250V weatherproof grounding type wall mounted.24No
69Double socket outlet, 13A, 250V grounding type wall mounted at 15 cm from top of counter level.18No
Supply, install, test & commission Lighting fixtures complete with luminaries, ceiling roses, heat resisting flexible cables switches and mounting accessories as per project drawings and technical specifications
70Ref. C64No
71Ref. F48No
72Ref. F4(EMERGENCY)2No
73Ref.M5205No
To CollectionSR
DIVISION 08 - ELECTRICAL
Supply, install, test & commission Lighting and power panelboards including circuit breakers, grounding, fixings, markers and directory required for complete installation as per project drawings and technical specifications
74Ref. MDP1No
75Ref.MPC1No
76Ref. LPP1No
77Ref. SDP1No
78Ref. DPEF1No
79Ref. PPFR1No
FIRE DETECTION AND ALARM SYSTEM INSTALLATION
Supply, install, test & commission fire detection and alarm system comprising optical type smoke detector, heat detector, optical smoke detector duct mounted, fire alarm control panel (FACP), alarm bells, manual stations and twisted fire resistant shielded cable including all zone wiring via 2 x 1.5 mm² cu-micc fire alarm cables in 20 mm dia PVC conduits as per project drawings and technical specifications, fire alarm panel should include power source, rechargeable battery, battery charger for a network consists of:
80Fire alarm control panel (2-zone), addressable type1No
81Optical smoke detector ceiling mounted4No
82Heat detector1No
83Fire alarm bell with flasher.1No
84Interface unit with AC system on the roof.1No
To CollectionSR
IP- TELEPHONE SYSTEM
Supply, install, test & commission complete IP- telephone system including equipment, devices, cable, conduit, boxes, and other accessories deemed necessary, complete as per drawings and signal corps specifications
UTP cat 6 patch cable 25 cm long8No
UTP cat-6 drop cable 3.0 m long.8No
SC-LC fiber optics patch panel, 12 ports.1No
COMPUTER SYSTEM
Supply, install, test & commission complete computer system comprising of computer cabinets, fittings and ports as per technical specifications and drawings
Connection cable between patch panel and network distributor, UTP Cat6 Patch cable, 25 cm long8No
Network point including fittings/conduiting from network receptacle until communication cabinet, copper wires (UTP Cat6 cables)8No
Connection cable between network port and computer (UTP Cat6 Drop cable) 3m long8No
Fiber optics Patch Panel (Single Mode FO) including 12 nos. fiber optic connections, type SC1No
Network distributer, 24 ports, RJ-45, speed 10/100 Mbps1No
Fiber optics port for network distributer, LX type1No
To Collection
PUBLIC ADDRESS SYSTEM INSTALLATION
Allow for the supply and installation of a complete three zone public address system comprising microphones and loudspeakers,including pull boxes, wiring, cabling,necessary fittings, supports and connections to buildings sound system comprising 120 w power amplifiers, (graphic equalizer,feedback suppresser, mixer frame) all as shown on drawings and as described in specification
Loudspeaker, ceiling mounted 6w10No
Microphone outlet2No
Microphone set with stand desk type2No
120 W power amplifier1No
Ground system equipment rack 16U at control room, ( G008 ) with fans, power strip 6 outlets and all related access, necessary fittings, supports and connections.1No
To CollectionSR

&L&"Arial,Bold"BILL NO. IFR

&C&"Times New Roman,Bold"&11&U INDOOR FIRING RANGE&R&"Arial,Bold"SITE 2 C &C&"Arial,Bold" IFR-&P / &[Pages

Bill Summary

ITEMDESCRIPTIONAMOUNT SR
BILL SUMMARY
Sheet -1SITEWORK
Sheet -2METALS
Sheet -3THERMAL AND MOISTURE PROTECTION
Sheet -4DOORS AND WINDOWS
Sheet -5FINISHES
Sheet -6SPECIALITIES
Sheet -7MECHANICAL
Sheet -9ELECTRICAL
To Tender Summary SR

&L&"Arial,Bold"BILL NO.: IFR

&C&"Times New Roman,Bold"&12&U

INDOOR FIRING RANGE&R&"Arial,Bold"SITE 2C

File details come from the government source that posted it. Updated .