This is an invitation for bid for the construction of an F-35 three-bay specialized hangar at Dane County Regional Airport in Madison, Wisconsin. The project scope includes demolishing an existing 19,875 square foot building and constructing a new 31,000 square foot three-bay hangar facility to support F-35 operations such as fuel cell maintenance, indoor washing, and weapons loading training. The facility will also include administrative offices and shops. The contract is valued between $25-100 million and will be a fixed-price contract awarded to the responsive, responsible lowest bidder. The solicitation includes a base bid for construction and two options for a paint/mix addition and aircraft rated pavement. A site visit will be held and bids are due by August 2nd, 2022. The North American Industry Classification for this project is 236220 and the contracting agency is the Department of the Army National Guard.
View the file
Other files for this federal contract opportunity
Show all 50
F-35 THREE BAY SPECIALIZED HANGAR has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MEANS OF EGRESS REQUIREMENTS - 2018 NFPA 101 (U.N.O.)
SPECIAL PURPOSE INDUSTRIAL
(AIRCRAFT HANGARS)
OCCUPANT LOAD
FACTOR
BUSINESS USE
GENERAL PURPOSE
INDUSTRIAL USE
STORAGE/ MECHANICAL
USE
MAX. PROBABLE # OF
OCCUPANTS PRESENT
AT ANY TIME PER NFPA
101, TABLE 7.3.1.2
150 GROSS
(TABLE 7.3.1.2)
100 GROSS
(TABLE 7.3.1.2)
500 GROSS
(TABLE 7.3.1.2)
COMMON PATH
OF TRAVEL
100'
(TABLE 40.2.5.1)
100' (38.2.5.3.1)
100' (40.2.5)
100' (42.2.5)
MAXIMUM TRAVEL
DISTANCE TO EXITS
EXTERIOR INTERVAL
150' (40.6.2.2)
300' (38.2.6.3)
250'
(TABLE 40.2.6.1)
400'
(TABLE 42.2.6)
MINIMUM EXIT ACCESS
CORRIDOR WIDTH
44" (38.2.3.2)
36" (7.3.4.1)
36" (7.3.4.1)
50' (40.6.4)
50' (38.2.5.2.1)
50'
(TABLE 40.2.5.1)
100'
(TABLE 42.2.5)
MAXIMUM DEAD END
CORRIDOR LENGTH
MINIMUM NUMBER
OF EXITS
(40.6.2.1)
PER OCCUPANT
LOAD
(40.2.4.1.1)
CODE SUMMARY
OCCUPANCIES (IBC 2018)
ITEM 2018 IBC REQUIREMENT (U.N.O.)
GENERAL
BUSINESS, GROUP B (304.1) - OFFICE AREAS, ACCESSORY AREAS
HIGH HAZARD GROUP H-2 - SUPPORT SHOP (ALTERNATE BID)
STORAGE, GROUP S-1 (311.2) - MECHANICAL, ELECTRICAL AND
STORAGE AREAS.
STORAGE, GROUP S-2 (311.3) - LAUNDRY ROOMS
OCCUPANCIES (NFPA 101, 2018) BUSINESS (6.1.11) - OFFICE AREAS
SPECIAL PURPOSE INDUSTRIAL, SPI (40.1.2.1.2) - HANGAR AREAS
CONSTRUCTION TYPE TYPE II-B (IBC, TABLE 601)
ALLOWABLE HEIGHT/STORIES UNLIMITED HEIGHT (UFC, 4-211-01, 3-3.1.7)/3 STORIES (IBC, TABLE 504.4)
ALLOWABLE AREA UNLIMITED ONE STORY (IBC 507.4)
ADAAG FULLY COMPLIANT
FIRE PROTECTION SYSTEMS
AIRCRAFT SERVICING AREA WET PIPE SPRINKLER SYSTEM (UFC 3-600-01 FIRE PROTECTION)
ADMINISTRATION AND SHOPS WET PIPE SPRINKLER SYSTEM (UFC 3-600-01 FIRE PROTECTION)
FIRE RESISTANCE REQUIREMENTS
BOILER ROOMS, FURNACE
ROOMS, AND GENERAL
STORAGE ROOMS OVER 100 SF
1 HOUR OR AUTOMATIC FIRE EXTINGUISHING SYSTEM
(TABLE 509)
NON-LOADBEARING EXTERIOR
WALLS
0 HOUR (TABLE 602)
HANGAR COLUMNS 0 HOUR (UFC 4-211-01, 3-3.1.2)
FLOOR CONSTRUCTION 0 HOUR (TABLE 601)
ROOF CONSTRUCTION 0 HOUR (TABLE 601)
FIRE SEPARATION REQUIREMENTS
BUILDING DATA
BUILDING AREA
GROUND FLOOR
HANGAR BAYS
ADMINISTRATIVE AREAS
ACCESSORY STO AND MECH
16,574 SQUARE FEET
2,838 SQUARE FEET
3,559 SQUARE FEET
BUILDING CODES AND STANDARDS
INTERNATIONAL MECHANICAL CODE 2018
INTERNATIONAL BUILDING CODE 2018
NATIONAL ELECTRICAL CODE 2020
NFPA 101 LIFE SAFETY CODE 2018
MINIMUM EGRESS WIDTH 0.2" PER OCCUPANT (NFPA 101, TABLE 7.3.3.1)
EXIT ENCLOSURES 1 HOUR (NFPA 101, 7.1.3.2.1), 1 HOUR DOORS (NFPA 101, 8.3.2.2)
BETWEEN AIRCRAFT SERVICING
AREAS AND ALL OTHER OPERATIONS
1 HOUR (UFC 04-211-01, 3-3.1.2)
DRAFT CURTAINS RECTANGULAR ROOF POCKETS, MAX. 7,500 SF (UFC 4-211-01, 3-3.1.10)
BETWEEN ALL OTHER OCCUPANCIES NOT REQUIRED - MIXED USE NONSEPARATED PER 508.3.2
TOTAL (GROSS SQUARE FEET) 22,968 SQUARE FEET
NFPA 409, STANDARD FOR AIRCRAFT HANGARS 2016
NATIONAL FIRE CODES (NFPA) LATEST EDITIONS
ICC/ANSI A117.1 2003
UNIFORM FEDERAL ACCESSIBILITY STANDARD (UFAS)
UFC 3-600-01, FIRE PROT. ENGINEERING FOR FACILITIES
UFC 1-200-01, GENERAL BUILDING REQUIREMENTS
UFC 4-010-01, MINIMUM ANTI-TERRORISM STANDARDS
ADDITIONAL UNIFIED FACILITY CRITERIA
ACCESSIBILITY FOR FIREFIGHTING
ALL WEATHER ACCESS MUST BE PAVED TO WITHIN 10M
(33 FT) FROM THE BUILDING (UFC 4-211-01, 3-3.1.11)
FIRE DEPARTMENT ACCESS ROADS
MUST COMPLY WITH NFPA 1 (18.2.3.5.1) ACCESS
ROADS SHALL HAVE AN UNOBSTRUCTED WIDTH OF
NOT LESS THAN 20 FT.
PORTABLE FIRE EXTINGUISHERS - 2018 NFPA 10 (U.N.O.)
EXTINGUISHER SELECTION
MAX TRAVEL DISTANCE
CLASSIFICATION OF
HAZARD
EXTRA (HIGH) 5.4.1.3 HANGAR
BAY
ORDINARY (MODERATE) 5.4.1.2 -
STORAGE, SUPPORT SHOP
4A:60B:C
B: 50 FEET (TABLE 6.3.1.1)
LIGHT (LOW) 5.4.1.1
OFFICE AREAS
20A:120B:C
B: 50 FEET (TABLE 6.3.1.1)
4A:60B:C
B: 50 FEET (TABLE 6.3.1.1)
FIRE PROTECTION ROOM 1 HOUR (UFC 4-211-01, 3-6.7)
INTERNATIONAL PLUMBING CODE 2018
UFC 4-021-01, DESIGN AND O&M: MASS NOTIFICATION
SYSTEMS
PER OCCUPANT
LOAD
ADJACENT BETWEEN AIRCRAFT
MAINTENANCE BAYS 2 HOURS FIGURE 3.1
PLUMBING MATRIX
WATER CLOSETS/URINALS
(MALE)
B
WATER CLOSETS (FEMALE)
LAVATORIES (MALE)
LAVATORIES (FEMALE)
1.4
0.38
0.93
0.23
S
0.35
0.22
0.35
0.22
1.75
0.60
1.28
0.45
REQUIRED PROVIDED
TOTAL PLUMBING FIXTURES
SERVICE SINKS
DRINKING FOUNTAINS
1 1 1 2
0.45 0.02 0.47 1
WATER CLOSETS (UNISEX)
LAVATORIES (UNISEX)
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
FSB2020-270-00
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
NWC / JBC
F-
3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin
Ai r N at io na l G ua rd
C
B
A
D
C
B
A
54321
DECEMBER 23, 2021
C :\U sers\gaz\D o cum ents\M y R evit\02700_Arch_G ZalabakZ5W
7D .rvt
6/8/2022 10:26: 55 AM
CODE SUMMARY
G-102
JBC
JRT/JBC
MP
OCCUPANCY AREA SCHEDULE
IBC Occupancy Classification
NFPA
Occupancy
Classification
ROOM
AREA
IBC Occupant Load Factor
NFPA
Occupant
Load Factor
IBC
Occupant
Load
NFPA
Occupant
Load REMARKSNUMBER NAME
B BUSINESS
B BUSINESS Business 102 VEST 50 SF 150 SF 150 SF 0.33 0.36 B BUSINESS Business 103 SHARED OFFICE 300 SF 150 SF 150 SF 2.00 1.88 B BUSINESS Business 104 FUEL OPEN
OFFICE
509 SF 150 SF 150 SF 3.40 3.35
B BUSINESS Business 105 VEST 120 SF 150 SF 150 SF 0.80 0.84 B BUSINESS Business 106 CORR 826 SF 150 SF 150 SF 5.50 5.27 B BUSINESS Business 107 CLASSROOM 602 SF 150 SF 150 SF 4.01 3.99 B BUSINESS Business 108 OFFICE 117 SF 150 SF 150 SF 0.78 0.78 B BUSINESS Business 109 RR W 164 SF 150 SF 150 SF 1.09 0.89 B BUSINESS Business 110 WING WEAPONS
MGR
125 SF 150 SF 150 SF 0.83 0.82
B BUSINESS Business 111 RR M 164 SF 150 SF 150 SF 1.09 0.95 B BUSINESS Business 112 FUEL SUPERVISOR 135 SF 150 SF 150 SF 0.90 0.81 B BUSINESS Business 113 BREAK/ TRAINING 551 SF 150 SF 150 SF 3.67 3.47 B BUSINESS Business 114 VEST 159 SF 150 SF 150 SF 1.06 1 B BUSINESS Business 115 OFFICE 125 SF 150 SF 150 SF 0.83 0.85 B BUSINESS Business 116 VINYL OPEN
OFFICE
492 SF 150 SF 150 SF 3.28 3.24
B BUSINESS Business 120A VEST 73 SF 150 SF 150 SF 0.48 0.58 B BUSINESS Business 120B CORR 717 SF 150 SF 150 SF 4.78 5.46 B BUSINESS Business 121 ELEC 78 SF 150 SF 150 SF 0.52 0.38 B BUSINESS Business 127 VEST 98 SF 150 SF 150 SF 0.66 0.64 B BUSINESS Business 130 CLEAN M RR 286 SF 150 SF 150 SF 1.90 1.93 B BUSINESS Business 131 CLEAN M LR 88 SF 150 SF 150 SF 0.59 0.58 B BUSINESS Business 132 CLEAN SHOWER M 51 SF 150 SF 150 SF 0.34 0.34 B BUSINESS Business 133 DIRTY SHOWER M 57 SF 150 SF 150 SF 0.38 0.38 B BUSINESS Business 134 DIRTY LR M 179 SF 150 SF 150 SF 1.19 1.19 B BUSINESS Business 135 DIRTY SHOWER M 56 SF 150 SF 150 SF 0.37 0.37 B BUSINESS Business 136 CLEAN W RR 254 SF 150 SF 150 SF 1.69 1.68 B BUSINESS Business 137 CLEAN W LR 88 SF 150 SF 150 SF 0.58 0.36 B BUSINESS Business 138 CLEAN SHOWER W 56 SF 150 SF 150 SF 0.37 0.37 B BUSINESS Business 139 DIRTY LR W 102 SF 150 SF 150 SF 0.68 0.68 B BUSINESS Business 140 DIRTY SHOWER W 61 SF 150 SF 150 SF 0.41 0.41 B BUSINESS Business 141 DIRTY RR UNISEX 49 SF 150 SF 150 SF 0.33 0.33 B BUSINESS Business 142 DIRTY VEST 247 SF 150 SF 150 SF 1.64 1.64
B BUSINESS: 32 6,976 SF 46.51 45.82
S-1 STORAGE
S-1 STORAGE Industrial 101 WEAPONS
TRAINING
6,314 SF 500 SF 500 SF 12.63 13.17
S-1 STORAGE Storage 117A MOTHER'S ROOM 83 SF 300 SF 0.28 S-1 STORAGE Storage 117B JAN 66 SF 300 SF 0.22 S-1 STORAGE Storage 118 FUEL MAINT.
GENERAL
STORAGE
275 SF 300 SF 0.92
S-1 STORAGE Industrial 119 FUEL CELL 4,782 SF 500 SF 500 SF 9.56 9.96 S-1 STORAGE Storage 124 MECH 709 SF 300 SF 2.36 S-1 STORAGE Storage 125 FIRE 730 SF 300 SF 2.43 S-1 STORAGE Storage 126 TOOLS 916 SF 300 SF 3.05 S-1 STORAGE Industrial 128 WASH BAY 4,878 SF 500 SF 500 SF 9.76 9.97 S-1 STORAGE Storage 129 JAN. 300 SF S-1 STORAGE Storage 143 MASK WASHING 30 SF 300 SF 0.10 S-1 STORAGE Storage 145 ELEC 309 SF 300 SF 1.03 S-1 STORAGE Storage 146 COMM 209 SF 300 SF 0.70
S-1 STORAGE: 13 19,301 SF 43.04 33.1
S-2 STORAGE
S-2 STORAGE Storage 122 FUEL 91 SF 300 SF 300 SF 0.30 0.23 S-2 STORAGE Storage 123 WASH 89 SF 300 SF 300 SF 0.30 0.23
S-2 STORAGE: 2 180 SF 0.60 0.46
TOTAL: 47 26,457 SF 90.15 79.38