This solicitation is for the construction of a Commercial Inspection Facility at the Tulsa Air National Guard Base in Tulsa, Oklahoma. The project scope includes options for portland cement concrete pavement instead of asphalt, addition of a visitor parking area, addition of Ameristar fencing with barrier cable, and addition of mow strips. The magnitude of the project is estimated between $1,000,000 to $5,000,000. This project is set aside 100% for small businesses with a North American Industry Classification of 236220 and size standard of $39,500,000. Offerors are encouraged to attend the pre-proposal conference. Award will be made based on best value as outlined in the solicitation. Funds are not presently available but are anticipated to be appropriated prior to award, as this project is on the National Guard priority list.
View the file
Other files for this federal contract opportunity
Show all 32
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 O F 4
ADDENDUM
This addendum forms a part of the contract documents and modifie s previous documents, specificat ions and drawings pertaining to these items dated July 21, 2022. The Contractor shall notify the architect immediate ly with any d iscrepancies or e rrors found in these documents.
DESCRIPTION
This addendum provides the Low Voltage and Te lecommunication d rawings and specifications dated July 21, 2022, addresses questions on seve ral of the Civil shee ts date July 21, 2022, and provides clarification for the various types of signage to be p rovided.
DRAWINGS
Archit e ct ural
1. Shee t A-502 – Details
1.1 Detail 9 – Monument Sign
- Provides add itional information for the footing and signage mate rials
Civil
2. Shee t CA402 – Bid Option Site Plan Block 2
2.1 Legend – Irregular Pane l
- Provides the Refe rence to shee t CP501 for irregular shaped paving pane ls
3. Shee t CA404 – Bid Option Site Plan Block 4
3.1 Legend – Irregular Pane ls
- Provides the Refe rence to shee t CP501 for irregular shaped paving pane ls
4. Shee t CP501 – Paving , Jointing , Curb & Ramp Details
4.1 Detail 9 – Irregular Pane l Re inforcement Detail
- Provides add itional information for re inforcement
ADDENDUM NO. Addendum 02
ADDENDUM DATE 7/21/2022
PROJECT OKANG Commercial Inspection Facility – Tulsa, Oklahoma
CLIENT Oklahoma Air National Guard – Tulsa, Oklahoma
ARCHITECT Cynte rgy AEC, LLC – 810 S. Cincinnati Ave ., Ste 200, Tulsa, OK 74119
2 O F 4
5. Shee t CP502 – Site Signage De tails
5.1 New Shee t
- Provides add itional information for p roject signage
6. Shee t CP503 – Site Signage De tails
6.1 Detail 2 – Traffic Signage De tail
- Provides add itional information for installation of p roject signage
7. Shee t CU501 – Utility De tails
7.1 Details A3 & C3 – Direct Buried Conduit (4x4) and (2x2) for Electrical Power and Communication
- Provides add itional information for the installation of conduits
8. Shee t CP502 – Site Signage De tails
8.1 New Shee t
- Provides add itional information for p roject signage
Communicat ions
9. Shee t TG101 – General Notes and Symbols
9.1 New Shee t
- Provides add itional information Communications and Low Voltage
10. Shee t TG102 – Responsib ility Schedule
10.1 New Shee t
- Provides add itional information Communications and Low Voltage
11. Shee t TS101 – Site Plan
11.1 New Shee t
- Provides add itional information Communications and Low Voltage
12. Shee t TS402 – Site Plan – Block 2
12.1 New Shee t
- Provides add itional information Communications and Low Voltage
13. Shee t TS404 – Site Plan – Block 4
13.1 New Shee t
- Provides add itional information Communications and Low Voltage
14. Shee t T-101 – Floor Plans
14.1 New Shee t
- Provides add itional information Communications and Low Voltage
3 O F 4
15. Shee t T-201 – Reflected Ce iling Plan
15.1 New Shee t
- Provides add itional information Communications and Low Voltage
16. Shee t T-301 – Elevation Views
16.1 New Shee t
- Provides add itional information Communications and Low Voltage
17. Shee t T-302 – Elevation Views
17.1 New Shee t
- Provides add itional information Communications and Low Voltage
18. Shee t T-401 – IDF/MDF Plans and Elevations
18.1 New Shee t
- Provides add itional information Communications and Low Voltage
19. Shee t T-501 – Te lecom Details
19.1 New Shee t
- Provides add itional information Communications and Low Voltage
20. Shee t T-502 – Outle t & Cable Labe ling Examples
20.1 New Shee t
- Provides add itional information Communications and Low Voltage
21. Shee t T-503 – Camera Installation De tails
21.1 New Shee t
- Provides add itional information Communications and Low Voltage
22. Shee t T-504 – Access Control System – Door Type C1 & Pole -Mount Camera De tail
22.1 New Shee t
- Provides add itional information Communications and Low Voltage
23. Shee t T-601 – Technology Diagrams
23.1 New Shee t
- Provides add itional information Communications and Low Voltage
24. Shee t T-602 – Security Schedules
24.1 New Shee t
- Provides add itional information Communications and Low Voltage
25. Shee t T-603 – Diagram, Functional, and Events & Alarms Matrix
25.1 New Shee t
- Provides add itional information Communications and Low Voltage
4 O F 4
SPECIFICATIONS
Communicat ions
1. 27 10 00 – Build ing Te lecommunications Cabling System
1.1 New Spec Section
- New
2. 27 13 23.00 40 – Communications Optical Backbone Cabling
2.1 New Spec Section
- New
3. 27 51 16 – Rad io and Public Address Systems
3.1 New Spec Section
- New
4. 28 05 26.00 40 – Grounding and Bonding for Electronic Safety and Security
4.1 New Spec Section
- New
5. 28 10 05 Electronic Security Systems (ESS)
5.1 New Spec Section
- New
6. 34 41 26.00 10 – Access Control Point Control System
6.1 New Spec Section
- New
Gene ral Comment
1. Signage – All signage to follow UFC 3 120 01 2003 Air Force Sign Standard requirements.
END OF ADDENDUM NARRATIVE
TULSA AIR NATIONAL GUARD BASE
Oklahoma Air National Guard
U.S. AIR FORCE
GATEHOUSE ROOF PLAN
119'-8"
AAAAA
MISC. METAL TRIM - MSM1
METAL FASCIA - MR1
7/8" HAT CHANNEL AT TOP
AND BOTTOM OF FASCIA
FLASHING DRIP EDGE
SOFFIT PANEL END CLIP
PRE-FINISHED SOFFIT PANEL - MS
EXPOSED STEEL STRUCTURE - PT-1
STEEL STRUCTURE
PRE-FABRICATED COLD FORMED
METAL ROOF TRUSS
PRE-FINISHED GUTTER AND
DOWNSPOUT - MSM1
1 1/2" METAL DECKING
CONTINUOUS UNDERLAYMENT,
5/8" EXT. PLYWOOD
STANDING SEAM METAL ROOF TO
MATCH BASE STANDARD - SSRM
4" / 1 2"
TOP MASONRY
111'-4"
PRE-FINISHED METAL GUTTER
DRIP EDGE
PRE-FORMED PRE-FINISHED
METAL FASCIA
5/8" EXT. PLYWD ON 1 1/2"
METAL DECKING
STANDING SEAM METAL ROOF
TO MATCH BASE STANDARD
4" / 12"
1'-4"
CONCRETE DECK,
RE: STRUCTURAL
2" CONTINUOUS
POLYISO
INSULATION
LOAD BEARING
CONCRETE MASONRY
CONTINUOUS EAVE VENT
W/ INSECT SCREENING
DRIP EDGE
4" 2 3/4"
/8
2'-8" 2'-8" 2'-8"
2" 3'-3" 2"
2" 1'-11 1/2" 2"2" 2'-2" 2"2" 1'-11 1/2" 2"
3/8" LINTLE SUPPORT PLATE
STRUCTURAL STEEL TUBE
CAST STONE
BRICK VENEER
BALLISTIC GLAZING SYSTEM
EL 103'-4"
4'-9 1/2"
2" 4'-0" 2"
3/8" LINTEL SUPPORT PLATE
BALLISTIC GLAZING SYSTEM
STRUCTURAL STEEL TUBE
CAST STONE
BRICK VENEER
EL 103'-4"
2'-2 5/8" 3'-3 3/8"
2"1'-3 1/2"2" 2" 2'-6" 2"
EL 103'-4"
3/8" LINTLE SUPPORT PLATE
STRUCTURAL STEEL TUBE
CAST STONE
BRICK VENEER
BALLISTIC GLAZING SYSTEM
2'-10 3/8"
2"2'-4 3/8"2"
3/8" LINTEL SUPPORT PLATE
BALLISTIC GLAZING SYSTEM
STRUCTURAL STEEL TUBE
CAST STONE
BRICK VENEER
EL 103'-4"
FIRST FLOOR
100'-0"
BRICK VENEER
/2
CAST STONE
CONCRETE
WALL
5" 1'-0" 5"
1'-10"
WEEP HOLES AT
24" ON CENTER
1/2" TO 1" MIN 1/8"
FINISHED WALL
ALUMINUM PLAQUE WITH 3" DIE
CUT VINYL LETTERS - WHITE,
HELVETICA MEDIUM
THREADED ALUMINUM STUD
MOUNTING
BACKGROUND FINISH WITH
SEMI-GLOSS BAKE ENAMEL ALL
AROUND. "STANDARD BLUE"
CLOSE ENDS WITH ALUMINUM SHEETING
CONTINUOUS WELD INTERIOR CORNERS,
MATCH COLOR OF SIGN
CHANGEABLE
PLAQUE
FINISHED WALL
ALUMINUM DIMENSIONAL LETTER,
HELVETICA MEDIUM
THREADED ALUMINUM STUD
MOUNTING
FINISH WITH SEMI-GLOSS
BAKED ENAMEL ALL AROUND,
"STANDARD BLUE"
1/2" TO 1" MIN 1/8"
CUT LETTERS EMBLEM / PLAQUE
#10 X 3/4" SOCKET HEAD
SELF-TAPPING SCREW
EMBLEM SHALL BE DIE CUT
VINYL OR REFLECTIVE SHEETING
APPLIED TO SIGN FACE - ALL
EMBLEMS TO BE FULL COLOR;
REFER BASE STANDARDS
0.08" ALUMINUM SHEETING
0.08" X 1" X 3/4" ALUMINUM ANGLE
WITH 1/4" DIAMETER MASONRY
EXPANSION ANCHOR
WELD CORNERS
FINISH WITH SEMI-GLOSS BAKED
ENAMEL ALL AROUND, "STANDARD
BLUE"
FINISHED WALL
12" X 12" “AIR COMBAT COMMAND” EMBLEM
BRICK SOLDIER COARSE
CAST STONE CAP
POLISHED ALUMINUM AIR FORCE EMBLEM
POLISHED ALUMINUM LETTERS, ARIAL BLACK
PREFINISHED ALUMINUM PANEL, WRAP TOP OF PANEL OVER
2” X 2” SQUARE ALUMINUM TUBE FRAME, SIGN FABRICATOR
TO DETERMINE ALL STRUCTURAL AND ATTACHMENT REQUIREMENTS
24” WIDE CONCRETE MOW STRIP UNDER SIGN
SPLIT-FACE CONCRETE
MASONRY UNIT
#4 DOWELS IN PAIRS AT 16" ON CENTER WITH
ACI STD HOOK IN FOOTING
#5's AT 12" ON CENTER
#4's AT 16" ON CENTER, EACH WAY
C L R
/2
/8
2" 2'-0" 1" 10'-0" 1" 2'-0" 2"
C L R
T
Y P
ALL SIDES
6"
VOLUME 1 OF 1
Sheet ____ of ____
SHEET
REFERENCE
NUMBER
Symbol Description Date ApprovedCONTRACT NUMBER:
PLOT DATE:
PLOT SCALE:
DWN BY: CHK BY: FILE NAME:
DATE:DESIGNED BY:
OKLAHOMA AIR NATIONAL GUARD
TULSA OK
BCE: KURT W. STEPHENS, Lt Colonel
A B C D E F G H
O R
IG
IN
A L
S E
A L E
D A
N D
S
IG
N E
D D
R A
W
IN
G S
A R
E O
N F
IL
E
A T
T H
E O
F F
IC
E
O F
T H
E B
A S
E C
IV
IL
E N
G
IN
E E
R
CYNTERGY
810 SOUTH CINCINNATI
2ND FLOOR
TULSA, OK 74119
918-877-6000
As indicated
C U s e rs
\w a lla c c
\D o c u m e n ts
\R e v it \C
IF
A rc h
S tr u c t_ c w a lla c e
S H
R
P .r v t
10168
A-502
W912L6-13-D-0002, TO 21
08/03/2021
CCW LDW
08/03/2021DFP
COMMERCIAL INSPECTION
FACILITY
PROJECT NUMBER: XHZG159052
DETAILS
A U
G U
S T
T Y
P E
B -3
F
IN
A L S
U B
M
IT
T A
L
F O
R C
O N
S T
R U
C T
IO
N
S T
A
TE OF OKLAHOM
A
LIC
ENSED ARCHIT
EC
T
DAVID F.
PHELPS
1 1/2" = 1'-0"1
CANOPY SOFFIT
1 1/2" = 1'-0"2
BUILDING SOFFIT
3/8" = 1'-0"3
EAST WINDOW
3/8" = 1'-0"5
SOUTH WINDOW
3/8" = 1'-0"6
NORTH WINDOW
3/8" = 1'-0"4
GUARD WINDOW
1 1/2" = 1'-0"7
CRASH ATTENUATOR
3" = 1'-0"8
SIGN DETAILS
TYPE B-3 FINAL SUBMITTAL 08/03/2021
1 ADDENDUM 1 07/21/2022
3/4" = 1'-0"9
MONUMENT SIGN
07/21/22
FI
BE
R
FI
BE
R
FI
BE
R
FI
BE
R
FI
BE
R
FI
BE
R
FI
BE
R
FI
BE
R
FI
BE
R
FI
BE
R
FI
BE
R
FI
BE
R
FI
BE
R
FI
BE
R
FI
BE
R
X
X
X
X
X
XXX
X
XXXXXXXXXXXXXXXXX
X
XXXX
X X
X X
X X
X X
X X
X X
X X
X X
X X
XFMR
CONC. LANE BASE BID
CO
CO
CO
1.5 0'
FH
1.
1.50'
BEGIN WALL
1.50'
1.
EXISTING SIDEWALK
1.50'
1.
GI
BIO RETENTION
AREA 2 SDMH
GI
SDJB
BIO RETENTION
AREA 1
PES GIBIO RETENTION
AREA 3
GI
CO
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
1.50'
41.50'
R
2.13'60'
58'64'
75'60'28' R
R
R
RR
R
R
RR
R
2.13'60'
33.00'
58'64'75'
7.
17'
R
R
R R
R
R
R
R
R
R
R
R
R
R
R
R
R R
R
R R
R
R
R
R
R
R R
R
R
R
RR
R
R
R
R
R
R
R
R
R
R
R
R R
R
R
R
R
R
R
R R
R R
R
R
R
R
R
R
R
60'28'
9'
4 - EQ. SPACES AT 15' = 60'
8.0'
6 - EQ. SPA'S AT 11.67' = 70'
7.
9'
6 - EQ. SPA'S AT 14' = 84'
7.
9'
9.20'
.5
0'
.5
0'
3/4" EXPANSION ALONG
GUTTER EDGE (TYP.)
15'
2 - EQ. SPA'S
AT 15' = 30'
3.
R R
R
14'
5- EQ. SPACES AT 15' = 75'
4 - SPA'S AT 11.5' = 46'
33.74'
33.00'
CLJ
CLJ
CLJ
CLJ
CLJ
CLJ
CLJ
CLJCLJ
CLJ
CLJ
C
TJ
C
TJ
C
TJ
C
TJ
C
TJ
C
TJ
C
TJ
C
TJ
C
TJ
C
TJ C
TJ
EJ
C
TJ
C
TJ
EJ EJ
EJ
EJ
EJ
EJ
EJ
BEGIN OPTION #4
MATCH LINE - RE: CA404
M
AT
C H
L
IN
E
- R
E:
C
A4
CA402
CA402.DWG
BID OPTION SITE PLAN
BLOCK 2
N. MINGO ROAD
80' RIGHT-OF-WAY
0 20' 40'
SCALE: 1" = 20'-0"
N
LIMITS OF
CONSTRUCTION
FUEL FACILITY NOT
IN CONTRACT
HGFEDCBA
AU
G
U
ST
, 2
- T
YP
E B-
FI
N
AL
S U
BM
IT
TA
L
- F O
R C
O N
ST
R
U C
TI
O
N v:
\O
KA
N
G \c if fa ci lit y\ D ra w in gs
\T yp e B2
\S he et \C
A4
.d w g
/2 1/
0:
A
M P lo tte d By
: c jo ne s
Pe n
Ta bl e:
C yn te rg y.
ct b
O R
IG
IN
AL
S
EA
LE
D A
N D
S
IG
N
ED
D R
AW
IN
G S
AR
E
O N
F
IL
E
AT
T H
E O
FF
IC
E O
F
TH
E
BA
SE
C
IV
IL
E N
G
IN
EE
R
138TH FIGHTER WING ApprovedDateDescriptionSymbol
DATE:
FILE NAME:
DESIGNED BY:
DWN BY: CHK BY:
PLOT DATE:
PLOT SCALE:
CONTRACT NUMBER:
SHEET
REFERENCE
NUMBER
Sheet of
05/27/2021
SAT
SAG
VOLUME 1 OF 1
COMBA
AIR MAND
COMT
COMMERCIAL INSPECTION
FACILITY RHR
OKLAHOMA AIR NATIONAL GUARD
TULSA OK
BCE: KURT W. STEPHENS, Lt Colonel
05/27/2021
CYNTERGY
810 SOUTH CINCINNATI
2ND FLOOR
TULSA, OK 74119
918.877.6000
W912L6-13-D-0002, TO 21
CYNTERGY
ENGINEERING, PLLC
CA # 3537
EXPIRES 6/30/2024
1:1
101 TYPE B-3 FINAL SUBMITTAL 08/03/2021
PROJECT NUMBER: XHZG159052
N MINGO ROAD
E
6t h
S
TR
EE
T
N
KEY PLAN
NOT IN
CONTRACT
NOT IN
CONTRACT
ADDENDUM 07/21/2022
PROPERTY LINE
PROPERTY LINE
KEY NOTES:
OPTION #1 - CONCRETE PAVEMENT
THROUGHOUT PROJECT SITE
OPTION #2 - VISITOR PARKING, WITH SIDEWALK
AND CROSSWALK TO GATE HOUSE
OPTION #3 - AMERISTAR IMPASSE II FENCE WITH
BARRIER CABLE AT FRONT ENTRY
OPTION #4 - MOW STRIP UNDER ALL FENCING
AND PASSIVE BARRIER THROUGHOUT PROJECT
SITE
DRAWING NOTES:
1. REFER TO CP101 FOR PAVEMENT MARKINGS
AND TRAFFIC SIGNS.
2. FOR BASE BID SITE PLANS REFER TO CS401
THROUGH CS406.
3. FOR CENTERLINE ALIGNMENT AND CURVE DATA
REFER TO SHEET CS601-CS603.
4. PROVIDE CONCRETE MOW STRIPE FOR BOTH
OPTION #3 AND OPTION #4.
CONTRACTION TRANSVERSE JOINT
CONTRACTION LONGITUDINAL JOINT
EXPANSION JOINT
CONSTRUCTION TRANSVERSE JOINT
CONSTRUCTION LONGITUDINAL JOINT
IRREGULAR PANEL RE: CP501
CTJ
CLJ
EJ
R
JOINTING LEGEND:
2 2
X
X
AVB AVB
1.50'
END FENCE
AND OPTION
#4
1.50'
EXISTING SEWER
LIFT STATION
TO REMAIN
8'
1.50'
LP
LP
LP
LP
LP
LP
LP
LP
1.50'
1.50'
.5
R
R
R R
R
R
R
R
3/4" EXPANSION ALONG
GUTTER EDGE (TYP.)
RRRR
R
R
R
R R
R
R R
R
R
R
R
R
4 - EQ. SPACES AT 14' = 56' 6 - EQ. SPA'S AT 12' = 70'
6.
12'12'
2.
8'
SP
AC
E
JO
IN
TS
A T
' O
N C
EN
TE
R
14'
13.5'14.33'
13.5'
10' 4' 10'
9.
5'
-S
PA
'S
A T
EQ. 4' EQ.
14'14'
C
LJ
C
TJ
C
TJ
C
TJ
CTJ
EP
EP
C
LJ
C
LJ
2'
12'11'9'
MATCH LINE - RE: CA406
MATCH LINE - RE: CA402
CA404
CA404.DWG
BID OPTION SITE PLAN
BLOCK 4
VI
PE
R S
TR
EE
T
0 20' 40'
SCALE: 1" = 20'-0"
N
PROPERTY
LINE
LIMITS OF
CONSTRUCTION
FUEL FACILITY NOT
IN CONTRACT
STAGING
AREA
HGFEDCBA
AU
G
U
ST
, 2
- T
YP
E B-
FI
N
AL
S U
BM
IT
TA
L
- F O
R C
O N
ST
R
U C
TI
O
N v:
\O
KA
N
G \c if fa ci lit y\ D ra w in gs
\T yp e B2
\S he et \C
A4
.d w g
/2 1/
0:
A
M P lo tte d By
: c jo ne s
Pe n
Ta bl e:
C yn te rg y.
ct b
O R
IG
IN
AL
S
EA
LE
D A
N D
S
IG
N
ED
D R
AW
IN
G S
AR
E
O N
F
IL
E
AT
T H
E O
FF
IC
E O
F
TH
E
BA
SE
C
IV
IL
E N
G
IN
EE
R
138TH FIGHTER WING ApprovedDateDescriptionSymbol
DATE:
FILE NAME:
DESIGNED BY:
DWN BY: CHK BY:
PLOT DATE:
PLOT SCALE:
CONTRACT NUMBER:
SHEET
REFERENCE
NUMBER
Sheet of
05/27/2021
SAT
SAG
VOLUME 1 OF 1
COMBA
AIR MAND
COMT
COMMERCIAL INSPECTION
FACILITY RHR
OKLAHOMA AIR NATIONAL GUARD
TULSA OK
BCE: KURT W. STEPHENS, Lt Colonel
05/27/2021
CYNTERGY
810 SOUTH CINCINNATI
2ND FLOOR
TULSA, OK 74119
918.877.6000
W912L6-13-D-0002, TO 21
CYNTERGY
ENGINEERING, PLLC
CA # 3537
EXPIRES 6/30/2024
1:1
101 TYPE B-3 FINAL SUBMITTAL 08/03/2021
PROJECT NUMBER: XHZG159052
N MINGO ROAD
E
6t h
S
TR
EE
T
N
KEY PLAN
NOT IN
CONTRACT
NOT IN
CONTRACT
ADDENDUM 07/21/2022
KEY NOTES:
OPTION #1 - CONCRETE PAVEMENT
THROUGHOUT PROJECT SITE
OPTION #2 - VISITOR PARKING, WITH SIDEWALK
AND CROSSWALK TO GATE HOUSE
OPTION #3 - AMERISTAR IMPASSE II FENCE WITH
BARRIER CABLE AT FRONT ENTRY
OPTION #4 - MOW STRIP UNDER ALL FENCING
AND PASSIVE BARRIER THROUGHOUT PROJECT
SITE
DRAWING NOTES:
1. REFER TO CP101 FOR PAVEMENT MARKINGS
AND TRAFFIC SIGNS.
2. FOR BASE BID SITE PLANS REFER TO CS401
THROUGH CS406.
3. FOR CENTERLINE ALIGNMENT AND CURVE DATA
REFER TO SHEET CS601-CS603.
4. PROVIDE CONCRETE MOW STRIPE FOR BOTH
OPTION #3 AND OPTION #4.
CONTRACTION TRANSVERSE JOINT
CONTRACTION LONGITUDINAL JOINT
EXPANSION JOINT
CONSTRUCTION TRANSVERSE JOINT
CONSTRUCTION LONGITUDINAL JOINT
IRREGULAR PANEL RE: CP501
CTJ
CLJ
EJ
R
JOINTING LEGEND:
DETAIL NOTE:
PCC - PORTLAND CEMENT CONCRETE
6" PCC (3500 PSI AIR ENTRAINED)
REFER TO TERRACON CONSULTANTS, INC. GEOTECHNICAL
ENGINEERING REPORT (PROJECT NO. 04175179) DATED:
AUGUST 7, 2017 FOR EARTHWORK, SITE PREPARATION,
PAVEMENTS AND SUBGRADE PRIOR TO PLACING PAVEMENT
SECTION OR BUILDING PAD.
6" ODOT TYPE 'A' AGGREGATE BASE
8" OF TREATED SUB-BASE OR 10" SELECT FILL
COMPACTED TO 95% OF STANDARD PROCTOR
DENSITY 3/4" BITUMINOUS
BOARD MATERIAL
SIDEWALK
4. CONTRACTOR TO VERIFY DESIRED FINISHES WITH OWNER PRIOR TO
CONSTRUCTION.
1. SAW CUT WEAKENED PLANE JOINT AS SOON AS POSSIBLE AFTER PLACEMENT OF
SLAB AND APPLY SILICONE JOINT SEALANT.
4" S
ID
EW
AL
K
1/ 2"
#5 SMOOTH DOWEL
BARS, 3' LONG
SPACED 1'-6" C.C.
CONCRETE
PAVING
SAWCUT AND SEAL
WITH FUEL RESISTANT
COLD APPLIED SILICON
JOINT SEALANT
R E:
P
AV
IN
G
SE
C
TI
O
N S2"
DOWELED CONSTRUCTION JOINT
1/4"
2"
1/8"
SAW CUT OR FORMED WEAKENED
PLANE JOINT FOR SIDEWALK
1/8" RADIUS
IF FORMED
3. PROVIDE TRANSVERSE JOINTS IN SIDEWALK AS FOLLOWS:
- 3/4 " EXPANSION JOINTS WHERE SHOWN OR AT 50' ON CENTER, AT CURVE
TANGENT POINTS, CORNERS AND ADJACENT TO CURB, STRUCTURES AND RAMPS.
- SAW CUT (WEAKENED PLANE) JOINTS AT 25' ON CENTER.
- 1/4 " GROOVES WITH 1/4 " RADIUS ON EDGES AT 5' ON CENTER.
2. PROVIDE TRANSVERSE JOINTS IN PAVEMENT AS FOLLOWS:
- 1" EXPANSION JOINTS AT THE BUILDING
- 3/4 " EXPANSION JOINTS WHERE SHOWN OR AT 80' ON CENTER MAXIMUM, AT
CURVE TANGENT POINTS, CORNERS AND ADJACENT TO STRUCTURES.
- SAW CUT (WEAKENED PLANE) JOINTS EQUAL DISTANCE BETWEEN EXPANSION
JOINTS AND GUTTER AT 12.5' ON CENTER TYPICAL, 15' MAXIMUM WHERE NECESSARY.
DETAIL NOTES:
4"R E:
P
AV
IN
G
SE
C
TI
O
N S
CONCRETE
PAVING
FUEL RESISTANT
COLD APPLIED SILICON
JOINT SEALANT
PAVEMENT 3/4"
SIDEWALK 1/2"
CONCRETE
PAVING M
IN
COMPACTED
EARTH
BACKFILL
FOC AND LAYOUT DIMENSION LINE
COMPACTED
SUBGRADE
REVERSE
GUTTER
6"2"
1.5' GUTTER
6"
1'
2" R
TYP
SLOPE 1/4"
PER FT
1"
FINISH GRADE, SLOPE
AWAY FROM SIDEWALK ( TYP. )
SLOPE TO DRAIN 2% MAX.
LIGHT BROOM FINISH
REFER TO PLAN FOR SIDEWALK WIDTH1/4" R
COMPACTED
SUBGRADE PROVIDE BUCKEYE
ULTRA FIBER 500 OR
APPROVED EQUAL AT
3 LB/CY
SCALE:
CONCRETE PAVEMENT DETAIL
NOT TO SCALE1
SCALE:
CONCRETE JOINT DETAIL
NOT TO SCALE2
SCALE:
CURB AND GUTTER DETAIL
NOT TO SCALE3
SCALE:
SIDEWALK DETAIL
NOT TO SCALE4
#5 SMOOTH DOWEL
BARS, 3' LONG
SPACED 1'-6" C.C.
4"
3"
EXPANSION JOINT
SCALE:
MOUNTABLE CURB DETAIL
NOT TO SCALE5
LAYOUT DIMENSION LINE
6"
1'-6"
#4 SMOOTH DOWEL
BARS, 3' LONG
SPACED 2'-6" C.C.
24" R
1'
12" R x x x x x x x x x x x
SECTION
SLOPE
1:10 SLO
PE
1:1
PLAN
SLOPE
12:1 MAX.
4' 6'
2'-5" 2'-5" 2'-5"
3' 2'
M
IN
DETAIL NOTE:
CONSTRUCTION RAMP IN
ACCORDANCE WITH AMERICAN
DISABILITY ACT REQUIREMENTS
SCALE:
ACCESSIBLE CURB RAMP
NOT TO SCALE6
FINISH
GRADE 4" PPC
SIDEWALK
W3 x W3 WELDED
WIRE MESH
NO. 5 TIE BARS,
2' LONG, AT 1.5'
MAX. ON CENTER
1/4 " x 1/2 " JOINT
SEALANT
BUTT JOINT
CURB BEYOND VARIES
FROM O" TO 6" HIGHSLOPE TO MEET
GUTTER LINE
TRANSITION
CURB 6" TO 0"
TOE OF GUTTER
6" CURB AND
GUTTER (FOC)
FLARED
SIDE (TYP.)
1/4" x 1/4" PV'MT SCORES
AT 3" ON CENTER
SIDEWALK OR LANDING
S= 1/4 "/ FT
x x x x x x x x x x x x x x x x x xx x x x x
SCALE:
AND DRAINAGE FLUME
TYPICAL CURB OPENING
NOT TO SCALE
4"
1.
5'
3'
(VARIES)
FLUME SLOPE NOT TO
EXCEED 2:1 OR 50%
2'
6" 6"
6"
VARIES
REFER TO GRADING PLAN
CONSTRUCTION JOINT
NO. 5 TIE BARS
3' LONG, AT 1.5'
MAX. ON CENTER6" PCC (3500 PSI)
WITH W3 x W3
WELDED WIRE MESH
CURB AND GUTTER
OPTIONAL ROLL-OVER
CURB (MOUNTABLE)
6" PCC (3500 PSI)
WITH W3 x W3
WELDED WIRE MESH
DETAIL
SECTION
PLAN
ROAD
DETAIL NOTE:
INTEGRAL CURB NOT ALLOWED
NO. 4 BARS
CONTINUOUS
CRUSHER RUN
4" AGGREGATE BASE
2" SMA (PG 76-28 OK)
2.5" ASPHALT
SUPERPAVE TYPE S3
(PG 76-28 OK)
SEPARATOR FABRIC
6" AGGREGATE BASE
MODIFIED SUBGRADE. SCARIFY AND RECOMPACT 8"
TO 95% STANDARD PROCTOR.
SEPARATOR FABRIC
(2' OVERLAP ON EDGES)
SCALE:
ASPHALT PAVEMENT DETAIL
NOT TO SCALE8
FUEL RESISTANT
COLD APPLIED SILICON
JOINT SEALANT
PANEL REINFORCEMENT NOTES:
1. CHAIR ASSEMBLIES SHALL BE OF A TYPE APPROVED
BY THE ENGINEER AND AT LEAST ONE CHAIR WILL BE
REQUIRED FOR EACH 16 SQUARE FEET OF PAVEMENT,
OR IN SUCH NUMBER AS TO FULLY SUPPORT THE
REINFORCING STEEL.
2. VIBRATION EQUIPMENT SHALL BE REQUIRED TO
ENSURE COMPLETE AND UNIFORM CONSOLIDATION OF
CONCRETE AROUND THE REINFORCING STEEL.
3. THE RECOMMENDED PLACEMENT OF THE
LONGITUDINAL STEEL IS TO BE SUPPORTED ON
TRANSVERSE STEEL & CHAIR ASSEMBLIES. CHAIR
ASSEMBLIES MUST BE USED.
#4 BAR
#4 BAR
#4 BAR
#4 BAR
#4 BAR
12" C/C (TYP. MAX) OR
EQUALLY SPACED
" C
/C (T
YP
. M
AX
) O
R
EQ
U
AL
LY
S
PA
C
ED
#4 BARS, BOTH WAYS
CHAIR ASSEMBLY 3"
C
LR
SECTION
PLAN
#4 BARS, BOTH WAYS
3" C
LR
3" CLR.
3" C
LR
3" CLR.
3' CLR.
SCALE:
IRREGULAR PANEL REINFORCEMENT DETAIL
NOT TO SCALE 9
HGFEDCBA
AU
G
U
ST
, 2
- T
YP
E B-
FI
N
AL
S U
BM
IT
TA
L
- F O
R C
O N
ST
R
U C
TI
O
N v:
\O
KA
N
G \c if fa ci lit y\ D ra w in gs
\T yp e B2
\S he et \C
P5
.d w g
/2 1/
0:
A
M P lo tte d By
: c jo ne s
Pe n
Ta bl e:
C yn te rg y.
ct b
O R
IG
IN
AL
S
EA
LE
D A
N D
S
IG
N
ED
D R
AW
IN
G S
AR
E
O N
F
IL
E
AT
T H
E O
FF
IC
E O
F
TH
E
BA
SE
C
IV
IL
E N
G
IN
EE
R
138TH FIGHTER WING ApprovedDateDescriptionSymbol
DATE:
FILE NAME:
DESIGNED BY:
DWN BY: CHK BY:
PLOT DATE:
PLOT SCALE:
CONTRACT NUMBER:
SHEET
REFERENCE
NUMBER
Sheet of
05/27/2021
SAT
SAG
VOLUME 1 OF 1
COMBA
AIR MAND
COMT
COMMERCIAL INSPECTION
FACILITY RHR
OKLAHOMA AIR NATIONAL GUARD
TULSA OK
BCE: KURT W. STEPHENS, Lt Colonel
05/27/2021
CYNTERGY
810 SOUTH CINCINNATI
2ND FLOOR
TULSA, OK 74119
918.877.6000
W912L6-13-D-0002, TO 21
CYNTERGY
ENGINEERING, PLLC
CA # 3537
EXPIRES 6/30/2024
1:1
101 TYPE B-3 FINAL SUBMITTAL 08/03/2021
PROJECT NUMBER: XHZG159052
ADDENDUM 07/21/2022
CP501
CP501.DWG
PAVING, JOINTING, CURB & RAMP
DETAILS 2 2
AHEAD
CELL
PHONE
R 16-5a-TEA
KEEP
RIGHT
CHICANE
CHECKPOINT
WRONG
WAY
R 2-5hP-TEA, R2-1 & R2-5P
W3-10a-TEA
WITH W16-9P
W1-5R WITH
W1-5P-TEA PLAQUE
R5 - 1a , R5 - 1aE , R5 - 1aF
COLOR:
LEGEND AND BORDER: WHITE
(REFLECTORIZED) BACKGROUND WITH
RED (TRANSPARENT REFLECTORIZED)
LETTERS AND TRIM
SPEED
LIMIT
UNLESS
OTHERWISE
POSTED
BASE NO
DO NOT
ENTER
WHEN DRIVING
R 22-1-TEA
USE
SEAT
BELTS
R 16-1b-TEA
USE
PARKING
LIGHTS
AT GATE
R
YIELD
R1-2 36x36x36
W6-3 36x36
R4-7a 24" x 30" 2 EACH: R5-1 "DO NOT ENTER" LED BLANK-OUT SIGN (30"x30") AND 12"
RED (TRANSPARENT
REFLECTORIZED) SIGNAL FACE
LEGEND AND BACKGROUND :
WHITE (REFLECTORIZED)
SOLAR POWERED
BARRIER
ACTIVATED
WHEN
FLASHING
FEET
W3-3b-TEA "BARRIER ACTIVATED WHEN
FLASHING" SIGN WITH AMBER FLASHING
BEACONS (36"x36")
W16-2P "110 FEET" SUPPLIMENTAL
WARNING PLAQUE (24"x18")
STOP
R1-1 30x30
SCALE:
CHECKPOINT SIGN
NOT TO SCALE1
SCALE:
SERPENTINE SIGN
NOT TO SCALE2 SCALE:
TWO WAY TRAFFIC SIGN
NOT TO SCALE4SCALE:
BARRIER SIGNAL
NOT TO SCALE3
SCALE:
FLASHING BARRIER SIGN
NOT TO SCALE11SCALE:
WITH GATE CLOSE SIGN
GATE REFLECTIVE STRIPE
NOT TO SCALE8 SCALE:
SPEED LIMIT SIGN
NOT TO SCALE9 SCALE:
YIELD SIGN
NOT TO SCALE10
SCALE:
STOP SIGN
NOT TO SCALE5
SCALE:
NO CELL PHONE
SIGN
NOT TO SCALE14
SCALE:
DO NOT ENTER SIGN
NOT TO SCALE18SCALE:
KEEP RIGHT SIGN
NOT TO SCALE17 SCALE:
DIRECTION SIGN
TRUCK LANE
NOT TO SCALE19
R6 - 1 (L) R6 - 1E (L)
COLOR:
ARROW AND BORDER:
WHITE (REFLECTORIZED)
LEGEND AND BACKGROUND:
BLACK (NON -
REFLECTORIZED)
SCALE:
ONE WAY SIGN
NOT TO SCALE13
ONE WAY
R4-32 TEA
CARS
TRUCKS
SCALE:
DIRECTION SIGN
VEHICLE LANE
NOT TO SCALE20
R4-5 - TRUCKS
USE RIGHT LANE
SCALE:
E1 WARNING AFB
NOT TO SCALE7
WARNING
U.S. Air Force Installation It is unlawful to enter this area without permission of the installation Commander Sec.21, Internal Security Act of 1950; 50 u.s.c. 797
While on this Installation all personnel and the property under their control are subject to search
SCALE:
DIRECTIONAL SIGN
WRONG WAY
NOT TO SCALE12
R11-2g-TEA
MOUNTED ON GATE
RETROREFLECTIVE
RED & WHITE
12" TALL x GATE LENGTH
SCALE:
SEAT BELT
SIGN
NOT TO SCALE15 SCALE:
PARKING LIGHTS
SIGN
NOT TO SCALE16
R10-13-TEA
36" X 24"
BARRIER
SIGNAL
SCALE:
STOP HERE SIGN
NOT TO SCALE6
ON
RED
STOP
USE
RIGHT
LANE
TRUCKS
R10-6A 24" X 30"
HERE36" x 36"
24" x 12"
36" x 36"
24" x 12"
48" x 30" 24" x 12"
24" x 30"
24" x 18"
36" x 36"
24" x 18" 36" x 24"
36" x 12"
36" x 36"
24" x 30" 24" x 30"
24" x 30" 78" x 36"
CP502
CP502.DWG
SITE SIGNAGE DETAILS
HGFEDCBA
AU
G
U
ST
, 2
- T
YP
E B-
FI
N
AL
S U
BM
IT
TA
L
- F O
R C
O N
ST
R
U C
TI
O
N v:
\O
KA
N
G \c if fa ci lit y\ D ra w in gs
\T yp e B2
\S he et \C
P5
.d w g
/2 1/
0:
A
M P lo tte d By
: c jo ne s
Pe n
Ta bl e:
C yn te rg y.
ct b
O R
IG
IN
AL
S
EA
LE
D A
N D
S
IG
N
ED
D R
AW
IN
G S
AR
E
O N
F
IL
E
AT
T H
E O
FF
IC
E O
F
TH
E
BA
SE
C
IV
IL
E N
G
IN
EE
R
138TH FIGHTER WING ApprovedDateDescriptionSymbol
DATE:
FILE NAME:
DESIGNED BY:
DWN BY: CHK BY:
PLOT DATE:
PLOT SCALE:
CONTRACT NUMBER:
SHEET
REFERENCE
NUMBER
Sheet of
05/27/2021
SAT
SAG
VOLUME 1 OF 1
COMBA
AIR MAND
COMT
COMMERCIAL INSPECTION
FACILITY RHR
OKLAHOMA AIR NATIONAL GUARD
TULSA OK
BCE: KURT W. STEPHENS, Lt Colonel
05/27/2021
CYNTERGY
810 SOUTH CINCINNATI
2ND FLOOR
TULSA, OK 74119
918.877.6000
W912L6-13-D-0002, TO 21
CYNTERGY
ENGINEERING, PLLC
CA # 3537
EXPIRES 6/30/2024
1:1
101 TYPE B-3 FINAL SUBMITTAL 08/03/2021
PROJECT NUMBER: XHZG159052
ADDENDUM 07/21/2022
NOTE:
ALL SIGN DIMENSIONS ARE PER MUTCD 2009 EDITION.
REFER TO SDDCTEA PAMPHLET 55-17 FOR ALL TEA
SIGNAGE
NOTE:
REFER TO UFC 3.120.01 FOR TYPE E1
WARNING SIGN DIMENSIONS
in
25in in
13in
4in
6 3/16in
5in
4 1/2in
26 1/2in 26 1/2in in
/8 in
/4 in
16 1/2in
12 1/2in
SCALE:
POLE - MOUNT RADAR SPEED SIGN
NOT TO SCALE1
YOUR
SPEED
CLEARANCE FOR INTERIOR
ACCESS
SPEED
LIMIT
YOUR
SPEED
CURB
SCALE:
TRAFFIC SIGN DETAIL
NOT TO SCALE2
2'
0m m
3.25' 991mm
7' -0
" A
LL
R O
AD
SI
G N
S m m
5" MAX.
152mm
1" 31mm
3.
1m m
1" 305mm
4" 122mm
DETAIL NOTES:
1. ALL SIGNS SHALL CONFORM TO THE UNIFIED FACILITIES
CRITERIA ( UFC) AIR FORCE SIGN STANDARDS LATEST ADDITION.
2. WHEN CURB IS NOT PRESENT, CENTERLINE OF POST SHALL BE
SET SEVEN FEET (2.1m) FROM EDGE OF PAVEMENT.
3. ALL SIGNS SHALL BE MADE FROM 100 ANODIZED ALUMINUM
CONCRETE FOOTING
10mm DIA. HOLES
MOUNT SIGN SECURELY
2 1/2" (65mm) 0.D. GALV.
STEEL SIGN POST
PROVIDE BREAK-AWAY
CONNECTION
HGFEDCBA
AU
G
U
ST
, 2
- T
YP
E B-
FI
N
AL
S U
BM
IT
TA
L
- F O
R C
O N
ST
R
U C
TI
O
N v:
\O
KA
N
G \c if fa ci lit y\ D ra w in gs
\T yp e B2
\S he et \C
P5
.d w g
/2 1/
0:
A
M P lo tte d By
: c jo ne s
Pe n
Ta bl e:
C yn te rg y.
ct b
O R
IG
IN
AL
S
EA
LE
D A
N D
S
IG
N
ED
D R
AW
IN
G S
AR
E
O N
F
IL
E
AT
T H
E O
FF
IC
E O
F
TH
E
BA
SE
C
IV
IL
E N
G
IN
EE
R
138TH FIGHTER WING ApprovedDateDescriptionSymbol
DATE:
FILE NAME:
DESIGNED BY:
DWN BY: CHK BY:
PLOT DATE:
PLOT SCALE:
CONTRACT NUMBER:
SHEET
REFERENCE
NUMBER
Sheet of
05/27/2021
SAT
SAG
VOLUME 1 OF 1
COMBA
AIR MAND
COMT
COMMERCIAL INSPECTION
FACILITY RHR
OKLAHOMA AIR NATIONAL GUARD
TULSA OK
BCE: KURT W. STEPHENS, Lt Colonel
05/27/2021
CYNTERGY
810 SOUTH CINCINNATI
2ND FLOOR
TULSA, OK 74119
918.877.6000
W912L6-13-D-0002, TO 21
CYNTERGY
ENGINEERING, PLLC
CA # 3537
EXPIRES 6/30/2024
1:1
101 TYPE B-3 FINAL SUBMITTAL 08/03/2021
PROJECT NUMBER: XHZG159052
ADDENDUM 07/21/2022
CP503
CP503.DWG
DETAILS 2 2
SCALE:
UTILITY TRENCH
NOT TO SCALEA5
SA
N
IT
AR
Y
SE
W
ER
W
AT
ER
L
IN
E
SE
W
ER
F
O R
C E
M
AI
N
SCALE:
TYPICAL SEWER CLEANOUT
NOT TO SCALEC5
DETAIL NOTES:
1. RISER DIAMETER TO MATCH DOWNSTREAM PIPE SIZE.
MAXIMUM RISER DIAMETER IS 10 INCHES (250 mm).
2. WHERE LINE DOES NOT EXTEND, INSTALL A PLUG OR
SUBSTITUTE A LENGTH OF STRAIGHT PIPE AND ANOTHER
45° ELBOW FOR WYE.
CONCRETE COLLAR
CAN BE POURED
MONOLITHIC OR WITH
BASE IN TWO POURS
PIPE SIZE. IN.
OD + 2'
TRENCH WIDTH. FT.
OD + 2.5'
OD + 3.5'
I D + 2' EACH SIDE OF PIPE
ID 24"*
24" ID 36"* *
36" ID 60"* *
ID _ 60"
SCALE:
STANDARD PIPE BEDDING DETAIL FOR STORM SEWER
NOT TO SCALEE5
(H
H
EI
G H
T O
F
ST
AN
D
AR
D
BE
D
D
IN
G M
AT
ER
IA
L
DETAIL NOTE:
STANDARD BEDDING MATERIAL MUST BE ODOT
*TYPE "A" AGGREGATE BASE. UNDER PAVING TYPE * "A"
AGGREGATE BASE MUST BE TO THE TOP OF THE *TRENCH.
TYPE "A" AGGREGATE BASE TO BE *COMPACTED TO 95%
STANDARD PROCTOR.
PROVIDE AND INSTALL UTILITY
LOCATOR TAPE AS REQUIRED
ONE FOOT BELOW FINISHED GRADE
NATURAL GROUND
EXCAVATED NATIVE BACKFILL
COMPACTED TO 95% STANDARD
DENSITY (ONE FOOT LIFTS)
TYPE AB FINE AGGREGATE
PIPE BEDDING COMPACTED
TO 95% STANDARD DENSITY
4"
12" PIPE
DIA.
12"
6"
2' M
IN
3' M
IN
4' M
IN
CONCRETE
PAVEMENT
HEAVY DUTY CAST
IRON FRAME & LID
SEE PLAN FOR FLOWLINE
ELEVATION AND PIPE SIZE
RE: NOTE 2
45° ELBOW
RISER - RE: NOTE 1
OUTFLOW
DOWNSTREAM
45° WYE
m m
2' SQUARE
610mm
NATIVE MATERIAL
STANDARD BEDDING MATERIAL
FINISH GRADE
UNDISTURBED
EARTH
PIPE CONDUIT
LIMITS OF STANDARD BEDDING MATERIAL
QUANTITIES FOR BEDDING MATERIAL DO NOT
INCLUDE THE SPACE WITHIN AND BOUNDED BY
THE OUTER SURFACE OF THE PIPE CONDUIT.
(W)
WIDTH OF TRENCH
EXCAVATION
6"
AV
ER
AG
E
H
EI
G H
T O
F
TR
EN
C
H E
XC
AV
AT
IO
N
M
IN
C O
LO
R
VA
R
IE
S
5"
1.
4m m
PLANE END -TYP
SCALE:
ELECTRICAL POWER AND COMMUNICATION
DIRECT BURIED CONDUIT (4x4) FOR
NOT TO SCALE
A3
SCALE:
ELECTRICAL POWER AND COMMUNICATION
DIRECT BURIED CONDUIT (2x2) FOR
NOT TO SCALE
C3
REPLACE DISTURBED SURFACE
WITH 4" NATIVE TOPSOIL AFTER
DUCT BANK INSTALLATION, TYP.
FINISH GRADE
WARNING TAPE ( 5.0 MIL, MIN. ) WITH
TRACER WIRE LABELED "ELECTRICAL
POWER OR COMMUNICATION"
COMPACTED 1" CLEAN ROCK
3" 6"
6" 4" 6"
TRAFFIC COVER EQUAL TO
GENERAL RATING OF PROJECT
SUMP PIT WITH
COVER
BACKFILL ON
ALL SIDES
FINISH GRADE
SET PULL BOX 1" ABOVE
TOP OF FINISHED GRADE
SECTION VIEW
PROVIDE
24"W x 36"L x 30"D
CONCRETE POLYMER
HAND HOLE
GRAVEL BASE
DETAIL NOTE:
CONTRACTOR SHALL PROVIDE GROUNDING ROD, CABLE RACK
SUPPORT, PULLING IRONS AND SUMP DRAIN FOR EACH PULL BOX
SCALE:
PULL BOX DETAIL
NOT TO SCALEF3
REPLACE DISTURBED SURFACE
WITH 4" NATIVE TOPSOIL AFTER
DUCT BANK INSTALLATION, TYP.
POWER CONDUCTORS OR
COMMUNICATION LINES
SAND ENCASEMENT
WARNING TAPE ( 5.0 MIL, MIN. ) WITH
TRACER WIRE LABELED "ELECTRICAL
POWER OR COMMUNICATION"
COMPACTED 1" CLEAN ROCK
3" 3"
6" 3" 6" DUCT SPACER SIZE FOR
RACEWAYS USED. TYPICAL
4" ELECTRICAL PVC CONDUIT
(IMC), TYP.
AT BASE SPACERS AS NEEDED
MASONRY LEVELING BLOCKS
FINISH GRADE
NO. 8 BARE COPPER WIRE ALIGNED
AT INSIDE TOP OF CONDUIT.
POWER CONDUCTORS OR
COMMUNICATION LINES
SAND ENCASEMENT
DUCT SPACER SIZE FOR
RACEWAYS USED. TYPICAL
4" ELECTRICAL PVC CONDUIT
(IMC), TYP.
NO. 8 BARE COPPER WIRE ALIGNED
AT INSIDE TOP OF CONDUIT.
HGFEDCBA
AU
G
U
ST
, 2
- T
YP
E B-
FI
N
AL
S U
BM
IT
TA
L
- F O
R C
O N
ST
R
U C
TI
O
N v:
\O
KA
N
G \c if fa ci lit y\ D ra w in gs
\T yp e B2
\S he et \C
U
1.
dw g
/2 1/
1:
A
M P lo tte d By
: c jo ne s
Pe n
Ta bl e:
C yn te rg y.
ct b
O R
IG
IN
AL
S
EA
LE
D A
N D
S
IG
N
ED
D R
AW
IN
G S
AR
E
O N
F
IL
E
AT
T H
E O
FF
IC
E O
F
TH
E
BA
SE
C
IV
IL
E N
G
IN
EE
R
138TH FIGHTER WING ApprovedDateDescriptionSymbol
DATE:
FILE NAME:
DESIGNED BY:
DWN BY: CHK BY:
PLOT DATE:
PLOT SCALE:
CONTRACT NUMBER:
SHEET
REFERENCE
NUMBER
Sheet of
05/27/2021
SAT
SAG
VOLUME 1 OF 1
COMBA
AIR MAND
COMT
COMMERCIAL INSPECTION
FACILITY RHR
OKLAHOMA AIR NATIONAL GUARD
TULSA OK
BCE: KURT W. STEPHENS, Lt Colonel
05/27/2021
CYNTERGY
810 SOUTH CINCINNATI
2ND FLOOR
TULSA, OK 74119
918.877.6000
W912L6-13-D-0002, TO 21
CYNTERGY
ENGINEERING, PLLC
CA # 3537
EXPIRES 6/30/2024
1:1
101 TYPE B-3 FINAL SUBMITTAL 08/03/2021
PROJECT NUMBER: XHZG159052
ADDENDUM 07/21/2022
CU501
CU501.DWG
UTILITY DETAILS 2 2
STANDARD TECHNOLOGY LEGEND
NOT ALL SYMBOLS AND NOTES MAY BE USED
DATA OUTLET LOCATION(S) INSTALLED ON WALL. CONTRACTOR SHALL PROVIDE 1" CONDUIT PATHWAY FROM EACH LOCATION TO THE NEAREST ACCESSIBLE CEILING SPACE TO A 1-GANG BACK BOX. COORDINATE DATA AND POWER LOCATIONS SO THAT DATA AND POWER ARE AT THE SAME HEIGHT AND IN CLOSE
PROXIMITY. CONTRACTOR SHALL PROVIDE AND INSTALL DATA CABLING TO 1-GANG BACK BOX,
FACEPLATE(S) AND JACK(S) AS SHOWN ON PLANS. REFERENCE DATA NOMENCLATURE FOR DATA OUTLET
QUANTITY AND INSTALLATION HEIGHT AND TYPE.
DATA OUTLET(S) INSTALLED IN FLOOR BOX. CONTRACTOR SHALL PROVIDE AND INSTALL A FLOOR BOX.
CONTRACTOR SHALL PROVIDE AND INSTALL 1" CONDUIT PATHWAY FROM NEAREST ACCESSIBLE CEILING SPACE TO FLOOR BOX LOCATION SHOWN ON PLANS. COORDINATE WITH MEP PLANS AND SHARE COMMON PATHWAY. CONTRACTOR SHALL PROVIDE AND INSTALL DATA CABLING TO FLOOR BOX, FACEPLATE(S) AND DATA JACK(S) TO EACH LOCATION SHOWN. REFERENCE DATA NOMENCLATURE FOR DATA OUTLET QUANTITY
AND INSTALLATION HEIGHT AND TYPE.
DATA OUTLET(S) INSTALLED ABOVE CEILING SPACE. CONTRACTOR SHALL PROVIDE AND INSTALL A 1-GANG BACK BOX 6" ABOVE CEILING. ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL 6" OF 1" CONDUIT PATHWAY FROM 1-GANG BACK BOX. CONTRACTOR SHALL PROVIDE AND INSTALL DATA CABLING TO 1-GANG
BACK BOX, FACEPLATE(S) AND DATA JACK(S) TO EACH LOCATION SHOWN.
PROJECT ACRONYMS
GENERAL PROJECT NOTES
01. ANY DIMENSIONS SHOWN ON THESE DRAWINGS ARE INTENDED TO PROVIDE A GENERAL LOCATION AS REQUESTED BY THE GOVERNMENT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONFIRMING ALL DIMENSIONS PRIOR TO ROUGH-IN AND IMMEDIATELY REPORT ANY CONFLICTS WITH THE OUTLET PLACEMENT.
02. ALL CABLE BUNDLES WILL BE SUPPORTED EVERY 48"-60" OC WITH A J-HOOK OR OTHER APPROVED PATHWAY DEVICE. REFERENCE SPECIFICATIONS AND DETAILS FOR ADDITIONAL CABLING PATHWAY INSTALLATION REQUIREMENTS. CONTRACTOR WHO VIOLATES THESE REQUIREMENTS WILL BE REQUIRED TO REPLACE THE
AFFECTED CABLE PLANT AT THEIR EXPENSE.
03. PLASTIC TIE WRAPS ARE NOT PERMITTED AT ANY TIME ON THIS INSTALLATION. ALL CABLE ROUGH-IN AND DRESS- OUT WILL BE WITH VELCRO ONLY. ALL CABLES BUNDLED WITH PLASTIC TIE WRAPS SHALL BE IMMEDIATELY
REPLACED AT THE CONTRACTOR'S EXPENSE.
04. DO NOT INSTALL ANY CABLES IN ANY CONDUIT SLEEVE, STUB UP, OR WALL CAP WITHOUT A PROTECTIVE BUSHING. CABLES PULLED INTO UNPROTECTED CONDUITS WILL BE REPLACED AT THE CONTRACTOR'S EXPENSE. DO NOT INSTALL ANY CABLING INTO ANY CONDUIT THAT HAS NOT BEEN CONFIRMED TO BE BLOWN CLEAR. COORDINATE
WITH DIVISION 26 PRIOR TO ROUGH IN OF ANY CABLING.
05. ANY CABLING FOUND PAINTED DURING THE CONSTRUCTION PROCESS WILL BE REPLACED AT CONTRACTOR'S EXPENSE. CONTRACTOR SHALL COORDINATE WITH THE GENERAL CONTRACTOR AND PAINTER TO AVOID CONFLICTS.
06. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO REFERENCE BOTH THE PROJECT DRAWINGS AND THE PROJECT SPECIFICATIONS. TOGETHER THEY FORM THE COMPLETE CONTRACT DOCUMENTS. PLEASE REFERENCE THE PROJECT SPECIFICATIONS FOR ALL MATERIALS, EQUIPMENT AND COMPONENTS NOT INDICATED ON THE
DRAWING SET.
07. CONTRACTOR SHALL COORDINATE ALL FINAL CAMERA LOCATIONS, HEIGHTS AND CAMERA VIEWING ANGLES WITH GOVERNMENT. FAILURE TO COORDINATE ALL FINAL CAMERA LOCATIONS, HEIGHTS AND VIEW ANGLES MAY REQUIRE
RELOCATION OF CONDUITS, CABLE AND CAMERA LOCATIONS AT CONTRACTOR'S EXPENSE.
08. CONTRACTOR SHALL COORDINATE TECHNOLOGY, TELECOM, SECURITY AND AUDIO VISUAL LOCATIONS SO THAT DATA AND POWER ARE AT THE SAME HEIGHT AND SPACED 18"-24" APART UNLESS SPECIFIED OTHERWISE.
REFERENCE TECHNOLOGY AND MEP SHEETS FOR COORDINATION.
09. ALL CATEGORY 6 AND COMMUNICATIONS CABLING INSTALLED IN AREAS WITH EXPOSED CEILINGS SHALL BE INSTALLED IN A MINIMUM 1" CONDUIT PATHWAY. CONDUIT PATHWAYS SHALL BE PROVIDED AND INSTALLED BY THE CONTRACTOR. THE CONDUIT MAY BE PAINTED TO MATCH CEILING COLOR AS DIRECTED BY THE CONTRACT
DOCUMENTS.
10. CONTRACTOR SHALL BE RESPONSIBLE FOR STOPPING ALL TECHNOLOGY, TELECOM, SECURITY AND AUDIO VISUAL CONDUIT PENETRATIONS FROM WATER OR RODENT INGRESS IN ALL BUILDINGS UPON COMPLETION OF THE
PROJECT.
XX #
OUTLET INSTALLATION TYPE:
OUTLET INSTALLATION LOCATION
# INDICATES QUANTITY OF DATA DROPS TO
BE INSTALLED
XX#
XX#
XX#
CC - OUTLET INSTALL 18" ON CENTER AFF
SC - OUTLET INSTALLED FOR SURVEILLANCE CAMERA
TV - OUTLET INSTALLED AT 8'-0" AFF UNO
WS - OUTLET INSTALLED ABOVE WORK SURFACE
DATA SYMBOLS LEGEND
AFF - ABOVE FINISHED FLOOR
AG - ABOVE GRADE
AHJ - AUTHORITY HAVING JURISDICTION
BBC - BACKBONE BONDING CONDUCTOR
BICSI - BUILDING INDUSTRY CONSULTING SERVICE INTERNATIONAL
C - CONDUIT
CD - CONSTRUCTION DOCUMENTS
CCTV - CLOSED CIRCUIT TELEVISION
CO - CONDUIT ONLY (EMPTY CONDUIT WITH MULE TAPE)
CP - CONTROL PANEL
CU - COPPER
DR - DOOR RELEASE
EC - ELECTRICAL CONTRACTOR
EF - ENTRANCE FACILITY
EL - EMERGENCY LOCK DOWN
EP - ENTRANCE POINT
ESS - ELECTRONIC SAFETY AND SECURITY
FBO - FURNISHED BY OTHERS
FCC - FEDERAL COMMUNICATIONS COMMISSION
GND - GROUND
HC - HORIZONTAL CROSS-CONNECT
HR - HOME RUN
HVAC - HEATING, VENTILATION, AND AIR CONDITIONING
IBO - INSTALLED BY OTHERS
IDF - INTERMEDIATE DISTRIBUTION FRAME
IEEE - THE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS
JB - JUNCTION BOX
LV - LOW VOLTAGE
MC - MAIN CROSS- CONNECT
MDF - MAIN DISTRIBUTION FRAME
MH - MANHOLE
MIC - MICROPHONE
MD - MOTION DETECTOR
MPOE - MAIN POINT OF ENTRY
NEC - NATIONAL ELECTRICAL CODE
NEMA - NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION
NIC - NOT IN CONTRACT
NTS - NOT TO SCALE
OC - ON CENTER
PB - PULL BOX
PBB - PRIMARY BONDING BUSBAR
PNL - PANEL
POC - POINT OF CONTACT
POE - POWER OVER ETHERNET
PP - PATCH PANEL
RCP - REFLECTED CEILING PLAN
RFI - REQUEST FOR INFORMATION
RFP - REQUEST FOR PROPOSAL
RMU - RACK MOUNT UNIT
SBB - SECONDARY BONDING BUSBAR
SMF - SINGLE MODE FIBER
SMR - SURFACE MOUNTED RACEWAY
SW - SWITCH
TBC - TELECOMMUNICATION BONDING CONDUCTOR
TE - TELECOMMUNICATIONS ENCLOSURE
TIA - TELECOMMUNICATIONS INDUSTRY ASSOCIATION
TYP - TYPICAL
UG - UNDERGROUND
UL - UNDERWRITERS LABORATORIES INC
UNO - UNLESS NOTED OTHERWISE
UPS - UNINTERRUPTIBLE POWER SUPPLY
USB - UNIVERSAL SERIAL BUS
WAP - WIRELESS ACCESS POINT
WP - WEATHER PROOF
DOOR POSITION SWITCH REQUIRED IN SPECIFIED DOOR. CONTRACTOR SHALL PROVIDE AND INSTALL 3/4" CONDUIT PATHWAY FROM NEAREST ACCESSIBLE CEILING SPACE TO THE TOP OF THE INSIDE OF THE DOOR FRAME FOR A DOOR CONTACT PATHWAY. COORDINATE CONDUIT PATHWAY WITH CONTRACTOR PRIOR TO FINAL ROUGH IN. CONTRACTOR SHALL PROVIDE AND INSTALL A DOOR POSITION SWITCH AT ALL LOCATIONS SHOWN ON PLANS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONNECT THESE DEVICES INTO THE ACCESS CONTROL PANEL. DOOR POSITION SWITCH NEEDS TO BE ON THE LATCH SIDE OF DOOR AT TOP NO
MORE THAN 6" FROM EDGE OF DOOR.
DS
INTERIOR SURVEILLANCE CAMERA, “X-C/E/WX" REFERS TO SECTION NUMBER - E, C, OR W DENOTES EXTERIOR, CEILING OR WALL-MOUNTED DEVICES - CAMERA NUMBER (SEE CAMERA SCHEDULE AND RESPONSIBILITY SCHEDULE FOR ADDITIONAL INFORMATION). COORDINATE ALL FINAL LOCATIONS, HEIGHTS AND VIEWING AREAS WITH THE OWNER/OWNER'S REPRESENTATIVE PRIOR TO FINAL INSTALLATION . CONTRACTOR SHALL USE SECTION 27 0000 SUPPLIED WORK AREA PATCH CORD TO CONNECT CAMERA(S). FAILURE TO COORDINATE ALL CAMERA LOCATIONS, HEIGHTS AND VIEWING ANGLES MAY RESULT IN RELOCATION OF CAMERA AND
CABLING AT CONTRACTOR'S COST.
X-X
X-X
EXTERIOR SURVEILLANCE CAMERA, “X-C/E/WX" REFERS TO SECTION NUMBER - E, C, OR W DENOTES EXTERIOR, CEILING OR WALL-MOUNTED DEVICES - CAMERA NUMBER (SEE CAMERA SCHEDULE AND RESPONSIBILITY SCHEDULE FOR ADDITIONAL INFORMATION). COORDINATE ALL FINAL LOCATIONS, HEIGHTS AND VIEWING AREAS WITH THE OWNER/OWNER'S REPRESENTATIVE PRIOR TO FINAL INSTALLATION. CONTRACTOR SHALL USE SECTION 27 0000 SUPPLIED WORK AREA PATCH CORD TO CONNECT CAMERA(S). FAILURE TO COORDINATE ALL CAMERA LOCATIONS, HEIGHTS AND VIEWING ANGLES MAY RESULT IN RELOCATION OF CAMERA AND
CABLING AT CONTRACTOR'S COST.
ACCESS CONTROL & SURVEILLANCE SYMBOLS LEGEND
KEY PAD AT SPECIFIED LOCATION. CONTRACTOR SHALL PROVIDE AND INSTALL 3/4" CONDUIT PATHWAY FROM NEAREST ACCESSIBLE CEILING SPACE TO BACK BOX INSTALLED 44" AFF. COORDINATE POWER WITH MEP AT THIS LOCATION. CONTRACTOR SHALL PROVIDE AND INSTALL SPECIFIED KEY PAD AT LOCATION SHOWN ON
PLANS. CONTRACTOR SHALL CONNECT KEY PAD INTO THE ACCESS CONTROL PANEL.
MD
KP
MD
JUNCTION BOX. CONTRACTOR SHALL PROVIDE AND INSTALL 3/4" CONDUIT FOR COMMUNICATIONS AND 1" CONDUIT FOR AV FROM ACCESSIBLE CEILING SPACE TO THE BACK BOX LOCATION SHOWN ON PLANS.
REFERENCE TECHNOLOGY DETAILS.
#XX
MOTION DETECTOR AT SPECIFIED LOCATION. CONTRACTOR SHALL SECURE AND SUPPORT MOTION
DETECTOR PER MANUFACTURER'S SPECIFICATIONS AND TO TYPE OF CEILING. REFERENCE
ARCHITECTURAL RCP PLANS FOR CEILING HEIGHT AND TYPE. CONTRACTOR SHALL COORDINATE WITH MEP PLANS FOR DEVICES ON THE GRID AND IN THE CEILING SPACE. FAILURE TO COORDINATE MAY RESULT IN RELOCATION OF THE MOTION DETECTOR AT CONTRACTOR'S EXPENSE. CONTRACTOR SHALL CONNECT
MOTION DETECTOR TO THE ACCESS CONTROL PANEL.
360 DEGREE MOTION DETECTOR AT SPECIFIED LOCATION. CONTRACTOR SHALL SECURE AND SUPPORT MOTION DETECTOR PER MANUFACTURER'S SPECIFICATIONS AND TO TYPE OF CEILING. REFERENCE ARCHITECTURAL RCP PLANS FOR CEILING HEIGHT AND TYPE. CONTRACTOR SHALL COORDINATE WITH MEP PLANS FOR DEVICES ON THE GRID AND IN THE CEILING SPACE. FAILURE TO COORDINATE MAY RESULT IN RELOCATION OF THE MOTION DETECTOR AT CONTRACTOR'S EXPENSE. CONTRACTOR SHALL CONNECT
MOTION DETECTOR TO THE ACCESS CONTROL PANEL.
JB
MD
WALL MOUNTED MOTION DETECTOR AT SPECIFIED LOCATION. CONTRACTOR SHALL SECURE AND SUPPORT MOTION DETECTOR PER MANUFACTURER'S SPECIFICATIONS. REFERENCE ARCHITECTURAL FLOOR PLAN DETAILS FOR WALL HEIGHT AND TYPE. CONTRACTOR SHALL COORDINATE WITH MEP PLANS FOR DEVICES LOCATIONS. FAILURE TO COORDINATE MAY RESULT IN RELOCATION OF THE MOTION DETECTOR AT CONTRACTOR'S EXPENSE. CONTRACTOR SHALL CONNECT MOTION DETECTOR TO THE ACCESS CONTROL
PANEL.
S1
S1
APPROXIMATE LOCATION OF CEILING MOUNTED INTERCOM SPEAKER LOCATION. CONTRACTOR SHALL PROVIDE AND INSTALL CEILING MOUNTED INTERCOM SPEAKER. CONTRACTOR SHALL SECURE AND SUPPORT PER MANUFACTURERS SPECIFICATIONS AND TO TYPE OF CEILING. REFERENCE ARCHITECTURAL RCP PLANS FOR CEILING HEIGHT AND TYPE. CONTRACTOR SHALL COORDINATE WITH MEP PLANS FOR DEVICES ON THE GRID AND IN THE CEILING SPACE. FAILURE TO COORDINATE WILL RESULT IN RELOCATION OF THE SPEAKER AT
CONTRACTOR'S EXPENSE.
APPROXIMATE LOCATION OF PAGING / INTERCOM SPEAKER/HORN. CONTRACTOR SHALL PROVIDE AND INSTALL 1" CONDUIT SLEEVE FROM NEAREST ADJACENT AND ACCESSIBLE CEILING SPACE TO BACK BOX INSTALLED 8'-0" AFF AND 10'-0" AFF OR AG UNO FOR ALL EXTERIOR LOCATIONS UNO. CONTRACTOR SHALL COORDINATE FINAL INSTALLATION LOCATION AND HEIGHT. NO POWER REQUIRED AT THESE LOCATIONS.
FAILURE TO COORDINATE MAY RESULT IN RELOCATION OF THE HORN AT CONTRACTOR'S EXPENSE.
PAGING, INTERCOM AND CLOCK SYMBOLS LEGEND
TECHNOLOGY + SECURITY CONSULTING
800.685.6440 www.cruxsolutions.com
VOLUME 1 OF 1
Sheet ____ of ____
SHEET
REFERENCE
NUMBER
Symbol Description Date ApprovedCONTRACT NUMBER:
PLOT DATE:
PLOT SCALE:
DWN BY: CHK BY: FILE NAME:
DATE:DESIGNED BY:
OKLAHOMA AIR NATIONAL GUARD
TULSA OK
BCE: KURT W. STEPHENS, Lt Colonel
A B C D E F G H
O R
IG
IN
A L
S E
A L
E D
A N
D S
IG
N
E D
D R
A W
IN
G
S A
R E
O N
F
IL
E A
T T
H E
O F
F
IC
E O
F T
H E
B A
S E
C
IV
IL
E
N G
IN
E
E R
CYNTERGY
810 SOUTH CINCINNATI
2ND FLOOR
TULSA, OK 74119
918-877-6000
07/21/2022 12" = 1'-0"
C U s e rs
\c c o y \D o c u m e n ts
\C
IF
T
E C
H c c o y T
P
N .r v t
TG-10105/27/21
JK JW
05/27/21LW
COMMERCIAL INSPECTION
FACILITY
PROJECT NUMBER: XHZG159052
GENERAL NOTES AND SYMBOLS
85 101W912L6-13-D-0002, TO 21
Addendum 07/21/20222 2
RESPONSIBILITY SCHEDULE
THIS SCHEDULE IS FOR REFERENCE AND DOES NOT INCLUDE ALL PROJECT COMPONENTS. IT SHALL BE USED IN CONJUNCTION WITH THE PROJECT DRAWINGS AND PROJECT SPECIFICATIONS.
SECTION DESCRIPTION DESIGNED BY: FURNISHED BY: INSTALLED BY:
27 1000 &
27 1323 BUILDING CABLING SYSTEMS & FIBER OPTIC CABLE BACKBONE CABLING FIRM RESPONSIBLE FOR DESIGN CONTRACTOR GOVERNMENT CONTRACTOR GOVERNMENT NOTES
DATA/VOICE/AP/CAMERA WORKSTATION CABLING CRUX X X
COPPER PATCH CORDS CRUX X X
FABRIC INNERDUCT CYNTERGY X X
FIBER OPTIC BACKBONE CABLING - OUTSIDE PLANT CRUX X X
FIBER OPTIC BACKBONE CABLING - INSIDE PLANT CRUX X X
SPLICING (COPPER AND FIBER) CRUX X X
FIBER PATCH CORDS CRUX X X
COPPER BACKBONE CABLE CRUX X X
EQUIPMENT CABINET CRUX X X
CABLE MANAGEMENT CRUX X X
MDF / IDF PATHWAYS CYNTERGY X X
FIRESTOPPING CRUX X X
GROUNDING CRUX X X
GROUNDING TIE INTO SERVICE GROUND CYNTERGY X X
LABELING CRUX X X
NETWORK SWITCH / CARDS / MODULES / CABLES / POWER SUPPLIES CRUX X X
UNINTERRUPTABLE POWER SUPPLY (UPS) CRUX X X
WIRELESS ACCESS POINT / AGREEMENTS / CONFIGURATION CRUX X X WIRELESS ACCESS POINTS TO BE CONFIGURED BY THE GOVERNMENT
POWER DISTRIBUTION UNIT (PDU) CRUX X X
IP PHONE SET OWNER X X
27 5116 RADIO AND PUBLIC ADDRESS SYSTEMS FIRM RESPONSIBLE FOR DESIGN CONTRACTOR GOVERNMENT CONTRACTOR GOVERNMENT NOTES
ZONE PAGE MODULE/AMPLIFIER CRUX X X
INTERCOM /PA SYSTEM HEAD END CRUX X X
CLOCK AND BELL SYSTEM N/A NOT APPLICABLE
CEILING SPEAKERS / HORNS CRUX X X
CLOCKS N/A
CD PLAYER N/A NOT APPLICABLE
28 08 10 ELECTRONIC SECURITY SYSTEM ACCEPTANCE TESTING FIRM RESPONSIBLE FOR DESIGN CONTRACTOR GOVERNMENT CONTRACTOR GOVERNMENT NOTES
SUBMITTALS CRUX X X
TEST EQUIPMENT N/A X X
TESTING OF ELECTRONIC SAFETY SYSTEMS CRUX X X
28 10 05 ELECTRONIC SECURITY SYSTEMS FIRM RESPONSIBLE FOR DESIGN CONTRACTOR GOVERNMENT CONTRACTOR GOVERNMENT NOTES
SECURITY SYSTEM MANAGEMENT SOFTWARE ADVANTOR X X
ACCESS CONTROL PANELS ADVANTOR X X
DOOR CONTROLLER ADVANTOR X X
POWER DISTRIBUTION UNIT ADVANTOR X X
DOOR POSITION SWITCHES ADVANTOR X X
DOOR POWER SUPPLIES N/A NOT APPLICABLE
REQUEST TO EXIT DEVICE N/A NOT APPLICABLE
CARD READERS N/A NOT APPLICABLE
DOOR RELEASE BUTTONS N/A NOT APPLICABLE
EMERGENCY ALARM BUTTONS ADVANTOR X X
ACCESS CONTROL WIRING ADVANTOR X X
AUXILIARY POWER SUPPLIES ADVANTOR X X
AUDIO/VIDEO INTERCOM SYSTEM N/A NOT APPLICABLE
ACCESS CONTROL SERVER OWNER X X ADVANTOR SYSTEM IS EXISTING, NEW DEVICES TO FUNCTION AS AN EXTENSION
MOTION SENSORS ADVANTOR X X
KEYPAD(S) ADVANTOR X X
DOOR SWITCHES ADVANTOR X X
CAMERAS - INDOOR / OUTDOOR CRUX X X
CAMERAS - LICENSES CRUX X X
VIDEO MANAGEMENT SOFTWARE OWNER X X SYSTEM IS EXISTING, NEW DEVICES TO FUNCTION AS AN EXTENSION
STORAGE CRUX X X CONTRACTOR TO PROVIDE ADDITIONAL STORAGE FOR ADDED CAMERAS
WIRING CRUX X X
OVERSPEED & DIRECTIONAL DETECTION SYSTEM CRUX X X INCLUDES MONITOR(S), SENSORS, WIRING, SOFTWARE, AND INSTALLATION
TAMPER SWITCHES (ENCLOSURES, MH/H LIDS, CONTROLS, ETC.) CRUX X X
DURESS BUTTONS ADVANTOR X X
TECHNOLOGY + SECURITY CONSULTING
800.685.6440 www.cruxsolutions.com
VOLUME 1 OF 1
Sheet ____ of ____
SHEET
REFERENCE
NUMBER
Symbol Description Date ApprovedCONTRACT NUMBER:
PLOT DATE:
PLOT SCALE:
DWN BY: CHK BY: FILE NAME:
DATE:DESIGNED BY:
OKLAHOMA AIR NATIONAL GUARD
TULSA OK
BCE: KURT W. STEPHENS, Lt Colonel
A B C D E F G H
O R
IG
IN
A L
S E
A L
E D
A N
D S
IG
N
E D
D R
A W
IN
G
S A
R E
O N
F
IL
E A
T T
H E
O F
F
IC
E O
F T
H E
B A
S E
C
IV
IL
E
N G
IN
E
E R
CYNTERGY
810 SOUTH CINCINNATI
2ND FLOOR
TULSA, OK 74119
918-877-6000
07/21/2022
C U s e rs
\c c o y \D o c u m e n ts
\C
IF
T
E C
H c c o y T
P
N .r v t
TG-10205/27/21
JK JW
05/27/21LW
COMMERCIAL INSPECTION
FACILITY
PROJECT NUMBER: XHZG159052
RESPONSIBILITY SCHEDULE
W912L6-13-D-0002, TO 21 86 101
AVB AVB
G A S
S E
RV
IC
E
R I
SE
R
G A S
S E
RV
IC
E
R I
SE
R
G A S
S E
RV
IC
E
R I
SE
R
BM 3
X F
M R
S T
OR
M
M A
NH
O
LE
S A N
ITA
R Y
S E W E R
W A
TE
R
V A
LV
E
W A
TE
R
V A
LV
E
S T O R M
M A N H O L E
W A T E R
V A L V E
F I R E
H Y D
P O W E R
P O L E
P O W E R
P O L E
P O W E R
P O L E
P O W E R
P O L E
SHEET NOTES:
REFERENCE SHEET TG-101 FOR ALL SYMBOLS AND PROJECT
SPECIFIC NOTES.
SHEET NOTES
REFERENCE SHEET TG-101 FOR ALL SYMBOLS AND PROJECT
SPECIFIC NOTES.
CONDUITS INSTALLED FOR COMMUNICATIONS CABLING
SHALL OBSERVE THE FOLLOWING PRACTICES:
A. USE OF SHARP OR NINETY DEGREE BENDS ARE NOT
ALLOWED. CHANGE OF DIRECTION SHALL USE WIDE
SWEEPING RADIUS BENDS.
B) VAULTS SHALL BE SIZED TO ACCOMMODATE CABLE BEND
RADIUS SHALL BE PLACED WHEN CONDUIT CHANGES
DIRECTION AS SHOWN ON DRAWINGS.
C) CABLE PULLING TENSION SHALL NOT EXCEED THE
MANUFACTURER'S RECOMMENDATIONS – PULL
METER SHALL BE USED TO MEASURE TENSION.
D) CONDUIT PATHWAY SHALL BE PROVIDED WITH A
METALLIC TRACER WIRE WITHIN THE SAME TRENCH
AS THE CONDUIT INSTALLED AT THE SAME LEVEL
FOR FUTURE LOCATION PURPOSES. IN ADDITION, A
WEATHER PROOF “FIBER OPTIC CABLE” MARKER
TAPE SHALL BE INSTALLED AT 18" ABOVE THE
CONDUIT TO NOTIFY ANYONE DIGGING IN THE EVENT
AN ELECTRONIC LOCATE WAS NOT PERFORMED TO
TRACE IN GROUND CONDUITS.
E) CONTRACTOR IS RESPONSIBLE FOR SEALING CONDUITS
INSIDE BUILDINGS TO ENSURE NO BUILDING INGRESS OF
WATER, INSECTS OR RODENTIA.
F) CONDUITS SHOULD TURN NO MORE THAN AN
ACCUMULATED 180 DEGREES BETWEEN TWO VAULTS. IF
FIELD CONDITIONS REQUIRE MORE THAN AN
ACCUMULATED 180 DEGREE TURN(S) BETWEEN TWO
VAULTS THE CONTRACTOR IS REQUIRED TO ADD A THIRD
VAULT BETWEEN THE TWO AFOREMENTIONED VAULTS IN A
LOCATION THAT REDUCES THE TURNS BETWEEN ANY TWO
OF THE VAULTS TO LESS THAN 180 DEGREES.
GATE HOUSE
INSPECTION
CANOPY
ID CHECK
ISLAND
OVERWATCH
POSITION
MOTORIZED
ROLLING GATE
APPROACH ZONE -
CONTRACTOR SHALL PROVIDE
OVERSPEED DETECTION VIA
ODDS IN THIS AREA.
RESPONSE ZONE -
CONTRACTOR SHALL
PROVIDE WRONG-
WAY DETECTION VIA
ODDS IN THIS AREA.
TECHNOLOGY + SECURITY CONSULTING
800.685.6440 www.cruxsolutions.com
VOLUME 1 OF 1
Sheet ____ of ____
SHEET
REFERENCE
NUMBER
Symbol Description Date ApprovedCONTRACT NUMBER:
PLOT DATE:
PLOT SCALE:
DWN BY: CHK BY: FILE NAME:
DATE:DESIGNED BY:
OKLAHOMA AIR NATIONAL GUARD
TULSA OK
BCE: KURT W. STEPHENS, Lt Colonel
A B C D E F G H
O R
IG
IN
A L
S E
A L
E D
A N
D S
IG
N
E D
D R
A W
IN
G
S A
R E
O N
F
IL
E A
T T
H E
O F
F
IC
E O
F T
H E
B A
S E
C
IV
IL
E
N G
IN
E
E R
CYNTERGY
810 SOUTH CINCINNATI
2ND FLOOR
TULSA, OK 74119
918-877-6000
07/21/2022 As indicated
C U s e rs
\c c o y \D o c u m e n ts
\C
IF
T
E C
H c c o y T
P
N .r v t
TS-10105/27/21
JK JW
05/27/21LW
COMMERCIAL INSPECTION
FACILITY
PROJECT NUMBER: XHZG159052
SITE PLAN
1" = 60'-0"1
SITE PLAN
N
PLAN
NORTH
N
TRUE
NORTH
W912L6-13-D-0002, TO 21 101
F
M R
1-E
01 02
KEYNOTE LEGEND
(NOT ALL KEYNOTES MAY APPLY)
X
01. CAMERA MOUNTED ON MONO POLE AT APPROXIMATELY
25'-0" AG.
02. 1" CONDUIT PATHWAY FROM GATE HOUSE TO CAMERA
POLE LOCATION. PROVIDE FIBER OPTIC CABLING AND MEDIA
CONVERTER AS-REQUIRED FOR FUNCTIONALITY. REFERENCE
SHEET TG-103 FOR EQUIPMENT LIST WITH PART NUMBERS.
03. 1" CONDUIT PATHWAY FROM DESK LOCATION IN GATE
HOUSE TO MOTORIZED GATE OPERATORS FOR CONNECTION
TO DELTA SCIENTIFIC CONTROLS TOUCHPAD.
SHEET NOTES:
REFERENCE SHEET TG-101 FOR ALL SYMBOLS AND PROJECT
SPECIFIC NOTES.
NOT IN
CONTRACT
NOT IN
CONTRACT
E th
S T
R E
N
N MINGO ROAD
G R A V E L
"R C
P
P P
W V
FH
W M
P P U G E
T R
P P
OH DR 8 'X 8 '
SF
PADMOUNTED E
LE
C T R
IC
A L
T R A N S F O M E R
PADMOUNTED E
LE
C T R
IC
A L
T R A N S F O M E R6
2 1
KEY PLAN
TECHNOLOGY + SECURITY CONSULTING
800.685.6440 www.cruxsolutions.com
VOLUME 1 OF 1
Sheet ____ of ____
SHEET
REFERENCE
NUMBER
Symbol Description Date ApprovedCONTRACT NUMBER:
PLOT DATE:
PLOT SCALE:
DWN BY: CHK BY: FILE NAME:
DATE:DESIGNED BY:
OKLAHOMA AIR NATIONAL GUARD
TULSA OK
BCE: KURT W. STEPHENS, Lt Colonel
A B C D E F G H
O R
IG
IN
A L
S E
A L
E D
A N
D S
IG
N
E D
D R
A W
IN
G
S A
R E
O N
F
IL
E A
T T
H E
O F
F
IC
E O
F T
H E
B A
S E
C
IV
IL
E
N G
IN
E
E R
CYNTERGY
810 SOUTH CINCINNATI
2ND FLOOR
TULSA, OK 74119
918-877-6000
07/21/2022 As indicated
C U s e rs
\c c o y \D o c u m e n ts
\C
IF
T
E C
H c c o y T
P
N .r v t
TS-40205/27/21
JK JW
05/27/21LW
COMMERCIAL INSPECTION
FACILITY
PROJECT NUMBER: XHZG159052
SITE PLAN - BLOCK 2
3/64" = 1'-0"1
SITE PLAN - BLOCK 2
N
PLAN
NORTH
0 10' 20' 40'
N
TRUE
NORTH
W912L6-13-D-0002, TO 21 88 101
Addendum 07/21/2022
AVB AVB
KEYNOTE LEGEND
(NOT ALL KEYNOTES MAY APPLY)
X
01. FURNISH AN OUTDOOR WEATHERPROOF DELTA
SCIENTIFIC CONTROL PANEL NEAR CHASE VEHICLE PARKING
LOCATION AND CONNECT TO THE NEARBY HPU FOR
GATE/BARRIER CONTROLS. PROVIDE FIBER OPTIC CABLING
AND MEDIA CONVERTER AS-REQUIRED FOR FUNCTIONALITY.
REFERENCE SHEET TG-103 FOR EQUIPMENT LIST WITH PART
NUMBERS.
SHEET NOTES:
REFERENCE SHEET TG-101 FOR ALL SYMBOLS AND PROJECT
SPECIFIC NOTES.
NOT IN
CONTRACT
NOT IN
CONTRACT
th
S
R E
N
N MINGO ROAD
G R A V E L
"R C
P
P P
W V
FH
W M
P P U G E
T R
P P
OH DR 8 'X 8 '
SF
PADMOUNTEDE
LE
C T R
IC
A L
T R A N S F O M E R
PADMOUNTEDE
LE
C T R
IC
A L
T R A N S F O M E R6
2 1
KEY PLAN
TECHNOLOGY + SECURITY CONSULTING
800.685.6440 www.cruxsolutions.com
VOLUME 1 OF 1
Sheet ____ of ____
SHEET
REFERENCE
NUMBER
Symbol Description Date ApprovedCONTRACT NUMBER:
PLOT DATE:
PLOT SCALE:
DWN BY: CHK BY: FILE NAME:
DATE:DESIGNED BY:
OKLAHOMA AIR NATIONAL GUARD
TULSA OK
BCE: KURT W. STEPHENS, Lt Colonel
A B C D E F G H
O R
IG
IN
A L
S E
A L
E D
A N
D S
IG
N
E D
D R
A W
IN
G
S A
R E
O N
F
IL
E A
T T
H E
O F
F
IC
E O
F T
H E
B A
S E
C
IV
IL
E
N G
IN
E
E R
CYNTERGY
810 SOUTH CINCINNATI
2ND FLOOR
TULSA, OK 74119
918-877-6000
07/21/2022 As indicated
C U s e rs
\c c o y \D o c u m e n ts
\C
IF
T
E C
H c c o y T
P
N .r v t
TS-40405/27/21
JK JW
05/27/21LW
COMMERCIAL INSPECTION
FACILITY
PROJECT NUMBER: XHZG159052
SITE PLAN - BLOCK 4
3/64" = 1'-0"1
SITE PLAN - BLOCK 4
N
PLAN
NORTH
0 10' 20' 40'
N
TRUE
NORTH
89W912L6-13-D-0002, TO 21 101
Addendum 07/21/202222
1-E
-E
1-E
1-E
1-E
KP
S
SHEET NOTES:
REFERENCE SHEET TG-101 FOR ALL SYMBOLS AND PROJECT
SPECIFIC NOTES.
KEYNOTE LEGEND
(NOT ALL KEYNOTES MAY APPLY)
X
01. FURNISH TWO (2) 4" CONDUITS FROM HAND HOLE TO
SECURITY NETWORK EQUIPMENT ENCLOSURE IN GATE
HOUSE. PROVIDE MULE TAPE AND NYLON BUSHINGS WITH THE
CONDUITS. SEAL BOTH ENDS OF THE CONDUIT TO PREVENT
WATER AND RODENTS FROM ENTERING THE CONDUITS.
02. LOCATE ODDS COMPUTER ON MILLWORK/DESK IN GATE
HOUSE. PROGRAM AUDIBLE AND VISUAL ALERTS FOR
OVERSPEED AND DIRECTIONAL DETECTION.
03. FURNISH DEDICATED 1" CONDUIT PATHWAY FROM EACH
CANOPY-MOUNTED SURVEILLANCE CAMERA (REFERENCE
T-201 FOR CEILING AND CANOPY-MOUNTED CAMERA
LOCATIONS) TO HAND HOLE.
04. FURNISH DEDICATED 1" CONDUIT PATHWAY FROM ID CHEK
ISLAND GATE/BARRIER CONTROLS TO HAND HOLE.
05. DBIDS ANTENNA LOCATION. EXTERNAL SOFFIT-MOUNT AND
PROVIDE COAX CABLE TO HEAD-END UNIT. COORDINATE WITH
138TH COMM TO ENSURE PROPER FUNCTIONALITY.
06. TELECOMMUNICATIONS HAND HOLE. REFERENCE CIVIL
PLANS FOR EXACT LOCATION AND REQUIREMENTS.
07. NETWORK OUTLET FOR CANOPY-MOUNTED SECURITY
CAMERAS.
08. FURNISH CAMERA AT 12'-0" ABOVE-GRADE.
09. FURNISH CAMERA AT 12'-0" ABOVE-GRADE.
10. FURNISH DEDICATED 1" CONDUIT PATHWAY FROM WS2 TO
EQUIPMENT CABINET.
DRIVER WAITING
GATE HOUSE
ACCESSIBLE TOILET
ID CHECK
CC4
CC4
WS4
WS4
TV1
TV1
T-3011T-301 2
T-401
ACS
C1
ACS
C1
ACS
C1
03 03
WS2
WS2
SC3
TECHNOLOGY + SECURITY CONSULTING
800.685.6440 www.cruxsolutions.com
VOLUME 1 OF 1
Sheet ____ of ____
SHEET
REFERENCE
NUMBER
Symbol Description Date ApprovedCONTRACT NUMBER:
PLOT DATE:
PLOT SCALE:
DWN BY: CHK BY: FILE NAME:
DATE:DESIGNED BY:
OKLAHOMA AIR NATIONAL GUARD
TULSA OK
BCE: KURT W. STEPHENS, Lt Colonel
A B C D E F G H
O R
IG
IN
A L
S E
A L
E D
A N
D S
IG
N
E D
D R
A W
IN
G
S A
R E
O N
F
IL
E A
T T
H E
O F
F
IC
E O
F T
H E
B A
S E
C
IV
IL
E
N G
IN
E
E R
CYNTERGY
810 SOUTH CINCINNATI
2ND FLOOR
TULSA, OK 74119
918-877-6000
07/21/2022 As indicated
C U s e rs
\c c o y \D o c u m e n ts
\C
IF
T
E C
H c c o y T
P
N .r v t
T-10105/27/21
JK JW
05/27/21LW
COMMERCIAL INSPECTION
FACILITY
PROJECT NUMBER: XHZG159052
FLOOR PLANS
3/16" = 1'-0"1
FLOOR PLAN N
PL…