Addendum 1.pdf

PDF 1 MB Posted

Attached to
Commercial Inspection Facility - Construction Federal contract opportunity
Solicitation number
W50S8U-22-R-0001
Issued by
Department of the Army National Guard

About this file

This solicitation is for the construction of a Commercial Inspection Facility for the Tulsa Air National Guard in Oklahoma. The project scope includes construction of the facility building, pavement, fencing, lighting, and landscaping. The work location is at the Tulsa Air National Guard Base. This is a 100% small business set-aside with a NAICS code of 236220 and size standard of $39.5 million. The anticipated contract value is between $1-5 million. The pre-proposal conference is strongly encouraged. The award will be made using best value determination. Funding is not presently available but is anticipated to be appropriated prior to award, as this project is on the National Guard's priority list. No contract will be awarded until funds are received. Responses are due in accordance with the solicitation issued by the Department of the Army National Guard.

View the file

Other files for this federal contract opportunity

Other files attached to Commercial Inspection Facility - Construction, newest first.
File Type Posted
Pre-Bid RFI CIF_1August22.pdf PDF
Brand_Name_Justification (Cisco_infrastructure) 1.0_Redacted.pdf PDF
Brand_Name_Justification (Corning_FODP) 1.0 s_Redacted.pdf PDF
Brand_Name_Justification Ameristar 1.1_Redacted.pdf PDF
ADDENDUM 2.pdf PDF
Brand_Name_Justification Gibralter 1.1_Redacted.pdf PDF
Brand_Name_Justification ALC 1.0_Redacted.pdf PDF
Brand_Name_Justification (Bosch_Camera) 1.0_Redacted.pdf PDF
Brand_Name_Justification (Aruba_Wireless) 1.0_Redacted.pdf PDF
W50S8U-22-R-0001 Amend 03 QA Extend Proposal Due Date.pdf PDF
Brand_Name_Justification (Telecor_PA) 1.0_Redacted.pdf PDF
Pre-Proposal RFI CIF_26July22.pdf PDF
Brand_Name_Justification Delta Scientific 1.1_Redacted.pdf PDF
Brand_Name_Justification Panduit_infrastructure) 1.0_Redacted.pdf PDF
Pre-Bid RFI CIF_20July22.pdf PDF
W50S8U-22-R-0001 Amend 01 Proposal Due Dates.pdf PDF
W50S8U-22-R-0001 Amend 02 Extend Proposal Due Date.pdf PDF
Pre-Proposal RFI CIF_7July22.pdf PDF
CIF Pre-proposal slides.pptx PPTX presentation
PreProposal Site Visit Minutes.pdf PDF
CIF Pre-proposal Attendance Sheet 23Jun22_Redacted.pdf PDF
EXHIBIT_D_Letter of Commitment.docx DOCX document
Attachment 1c Final Design Submittal Specs.pdf PDF
Attachment 2 Commercial Inspection Facility Drawings.pdf PDF
Attachment 1a Electronic Submittals-Addendum 1.pdf PDF
Attachment 1d Final Design Submittal Specs from Pages 29-30.pdf PDF
Attachment 1b Electronic Submittals-Addendum 2.pdf PDF
EXHIBIT_A_Performance_Questionnaire.doc DOC document
EXHIBIT_B_Subktr_InfoandConsent.doc DOC document
EXHIBIT_C_Reference_Questionnaire_Package.docx DOCX document
W50S8U-22-R-0001 Solicitation.pdf PDF
Attachment 3 Statement of Work.pdf PDF
Show all 32

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1 O F 1

ADDENDUM

This addendum forms a part of the contract documents and modifies previous documents, specifications and drawings pertaining to these items dated 08/03/2021. The Contractor shall notify the architect immediately with any discrepancies or errors found in these documents.

DESCRIPTION

This addendum revises the cable system specification on drawing CS504 from Gibraltar TL-3 to Gibraltar TL-4

Tamper Proof System. Please refer to the attached manufacturer’s drawing for additional information.

END OF ADDENDUM NARRATIVE

ADDENDUM NO. 1

ADDENDUM DATE 7/13/2022

PROJECT Commercial Inspection Facility – Tulsa, Oklahoma

CLIENT Oklahoma Air National Guard – Tulsa, Oklahoma

ARCHITECT Cyntergy AEC, LLC – 810 S. Cincinnati Ave., Ste 200, Tulsa, OK 74119

4d (2 1/2" MIN.)

R d

HOOK

d d

R

90° BEND

RE: SCHED.

EMBED

FACE OF

CONC.

TYP. LAP SPLICE

48d MASONRY

CONC. RE: SCHED.

R = 4d FOR #8 BARS OR SMALLER R = 5d FOR #9, #10 AND #11 BARS R = 6d FOR #14 AND #18 BARS

R = 2d

STIRRUP OR TIE

6d OR 4" MIN.

#3 30 39 8 #4 40 52 11 #5 50 65 13 #6 60 78 16 #7 87 113 18 #8 99 129 21

SIZE

TYP. LAP

LENGTH (IN)

TOP BAR LAP

LENGTH (IN)*

MIN. EMBEDMENT FOR

STD. 90° HOOK (IN)

3500 PSI CONCRETE REINFORCING LAP SPLICE

AND 90° HOOK LENGTHS SCHEDULE

*REFERS TO REINFORCING WITH MORE THAN 12 INCHES

OF CONCRETE PLACED BELOW.

T

SAWCUT CJ, FILL WITH

JOINT FILLER AT

EXPOSED JOINTS

1/8" X T/4 DEEP SAWCUT

CONTRACTION JOINT FOR

WET CUTTING OR EARLY

ENTRY SAW CUTTING

A. CONTROL JOINT DETAIL (C.J.)

T

RESAW CONSTRUCTION JOINT

1/8" X T/4 DEEP TO PRODUCE

VERT. SIDE WALL AND HORIZ.

SHELF TO SUPPORT JOINT

FILLER, FILL WITH JOINT FILLER

AT EXPOSED JOINTS

B. CONSTRUCTION JOINT DETAIL

T /4

T /4

1/2" DIA. x 1'-0" SMOOTH

BAR DOWELS AT 24" O.C.,

DOWELS MUST BE LEVEL

AND SQUARE WITH JOINT

6" 6"

HORIZ. REINF

IN WALL OR

FOOTING

HORIZ. REINF

IN WALL OR

FOOTING

CORNER BARS

TO MATCH HORIZ.

REINF., LAP BARS

48 BAR DIA. OR

24" WHICHEVER

IS GREATEST

UNLESS NOTED

OTHERWISE ON

THESE PLANS, TYP.

M

IN

B

A R

D

IA

P R

O J

" TOP OF

CONCRETE 1 1/2"

/2

HSS8x8x5/8

3/16

GRID

GRID

1'-2"

/2

1 1/2"

3/4" BASEPLATE WITH

(4) 3/4" DIA x 1'-0"

ANCHOR BOLTS

COMP. & CLADDING UPLIFT

ZONE

GROSS NET

1 18.9 10.9

AREA < 10 SQ FT AREA > 100 SQ FT

GROSS NET

16.3 8.3

2 39.9 31.9 26.8 18.8

3 63.6 55.6 47.8 39.8

2 OVERHANG

3 OVERHANG

53.1 45.1 53.1 45.1

92.5 84.5 61.0 53.0

GATE HOUSE

3 3

3 3

2 2

TYP

3'-0"

T Y

P

MWFRS UPLIFT

ZONE GROSS NET

A 24.30 16.3

B 10.90 2.9

GATE HOUSE

A

B

B

TYP

3'-0"

T Y

P

COMP. & CLADDING UPLIFT (CANOPY)

ZONE

AT ≤ 9 9< AT ≤ 36

1 -24.78

AT >36

2 -37.24 -37.24

3 -74.34 -37.24

CANOPY

T Y

P

TYP

3'-0"

-24.78 -24.78

-24.78

-24.78

14" SQ. FORMED CONCRETE

COLUMN WITH (4) #6 VERT

AND #3 TIES AT 12" OC

1" CABLE, PROVIDE

SLEEVES AS REQUIRED,

SEE FENCE SPEC

CONTINUE MOW STRIP

REINFORCEMENT THROUGH

2'-8" BLOCK. RE: CIVIL FOR

MOW STRIP

36" DIA x4'-0", 6000 PSI

CONCRETE PIER WITH

(8) #7 VERT. AND #3

TIES AT 12" OC

TOF EL

= 99'-6"

FINISHED GRADE OR

PAVING, RE: CIVIL

2'-8"x2'-8"x1'-0" WITH (1) #4

VERT IN EACH CORNER

AND #3 TIES (1) TOP AND

(1) BOT. PLACE CONTROL

JOINT BETWEEN BLOCK

AND MOW STRIP

NOTE:

1. FOR MASONRY VENEER

PILASTER LOCATIONS,

RE: SITE PLAN.

R E

A

R C

H

C L R

(4) #6 DOWELS x 6' -0"

EXTENDING 2'-6" INTO PIER

9" 1'-2" 9"

8" SQ. GALVANIZED POST

FILLED WITH 8,000 PSI

CONCRETE OR AS

SPECIFIED BY FENCH

MANUFACTURER. SEE

FENCE SPEC

1" CABLE

CONTINUE MOW STRIP

REINFORCEMENT THROUGH 1'-4"

BLOCK FIELD BEND AROUND

COLUMN. RE: CIVIL FOR MOW STRIP

36" DIA x5'-0", 6000 PSI

CONCRETE PIER WITH

(8) #8 VERT. AND #3

TIES AT 12" OC

CLR

2"

#7 VERT REINF

#3 TIES AT 12" OC

TOF EL

= 99'-6"

FINISHED GRADE OR

PAVING, RE: CIVIL

1'-4" SQ. CONCRETE WITH

CONTROL JOINT BETWEEN

BLOCK AND MOW STRIP.

NOTE:

1. FOR CABLE TERMINATION POST

AND "I" BEAM POST LOCATIONS,

SEE SITE PLAN.

2. FOR "I" BEAM POST FOUNDATION,

SEE FENCE MANUFACTURER.

C L R

CLR

1"

3" CLR. TYP.

M

IN

E

M B

E D

M E

N T

LIGHT POLE, BASE PLATE,

ANCHOR BOLTS, CONDUIT

AND GROUNDING

REQUIREMENTS. RE: ELEC

18" DIA. PIER WITH

(9) #8 VERT REINF

AND #3 TIES AT

16" OC, (3) IN TOP 5"

FINISHED GRADE,

RE: CIVIL

DIA

2'-6"

RE: 2/E-403 FOR ELEC.

INFORMATION

C L R

4000 PSI PORTLAND

CEMENT CONCRETE.

VIBRATED FROM BOTTOM

TO TOP. HAND RUB FINISH

ON EXPOSED PIER.

1" CHAMFER, TYP

M

A X

1'-6"

VOLUME 1 OF 1

Sheet ____ of ____

SHEET

REFERENCE

NUMBER

Symbol Description Date ApprovedCONTRACT NUMBER:

PLOT DATE:

PLOT SCALE:

DWN BY: CHK BY: FILE NAME:

DATE:DESIGNED BY:

OKLAHOMA AIR NATIONAL GUARD

TULSA OK

BCE: KURT W. STEPHENS, Lt Colonel

A B C D E F G H

O R

IG

IN

A L

S E

A L E

D A

N D

S

IG

N E

D D

R A

W

IN

G S

A R

E O

N F

IL

E

A T

T H

E O

F F

IC

E

O F

T H

E B

A S

E C

IV

IL

E N

G

IN

E E

R

CYNTERGY

810 SOUTH CINCINNATI

2ND FLOOR

TULSA, OK 74119

918-877-6000

As indicated

C U s e rs \s k e lt m c .A

E C

\D o c u m e n ts \R e v it \C

IF

A rc h

S tr u c t_ s k e lt m c .r v t

10153

S-004

W912L6-13-D-0002, TO 21

08/03/2021

MCS LLV

08/03/2021CMH

COMMERCIAL INSPECTION

FACILITY

PROJECT NUMBER: XHZG159052

GENERAL STRUCTURAL DETAILS

A U

G U

S T

T Y

P E

B -3

F

IN

A L S

U B

M

IT

T A

L

F O

R C

O N

S T

R U

C T

IO

N

L

IC

E N

S E

D P

R

OFESSIONA

L

E N

G I N

E E

R

OKL AHOMA

LARRY LEE

VORBA

11654

1 1/2" = 1'-0"1

REINF. LAP/BEND DIAGRAM

3/4" = 1'-0"2

TYP. CONTROL JOINT

3/8" = 1'-0"3

CORNER BAR DETAIL

1 1/2" = 1'-0"4

ANCHOR BOLT DETAIL

1" = 1'-0"5

TYP BASE PLATE DETAIL

3/32" = 1'-0"6

WIND DIAGRAM C&C

GATE HOUSE

3/32" = 1'-0"7

WIND DIAGRAM MWFRS

GATE HOUSE

3/32" = 1'-0"8

WIND DIAGRAM C&C CANOPY

3/4" = 1'-0"9

MASONRY VENEER PILASTER

3/4" = 1'-0"10

PILASTER AT FENCE POST

3/4" = 1'-0"11

TRAFFIC POLE FOUNDATION

CYNTERGY ENGINEERING, PLLC

CA # 3537

EXPIRES 6/30/2022

TYPE B-3 FINAL SUBMITTAL 08/03/2021

1541174164M Callout

CMU1

1541174164M Polygon

Pre-Bid RFI CIF_14July22.pdf
OKANG CIF - Add 1.pdf
TL-4 Tamper Proof System (rev13)

File details come from the government source that posted it. Updated .