RFI 02 response_attachment_B422 Breakroom 09 51 00.pdf

PDF 12 KB Posted

Attached to
B422 BREAKROOM, B300 BDOC
Solicitation number
W50S8R27BA002
Issued by

About this file

This is a specification document for acoustical ceiling installation and restoration work, issued as Section 09 51 00 in August 2020.

The specification requires replacement acoustical ceiling tile and suspension system components to restore disturbed ceiling areas and match existing conditions in size, profile, material, edge detail, finish, color, texture, and appearance. The basis of design for replacement tile is USG Ceilings No. 414, Shadowline Bevel Edge, 3/4 inch thick, 2 foot by 2 foot, Frost ClimaPlus, or approved equal. Replacement acoustical units must conform to ASTM E1264, while suspension system components must conform to ASTM C635/C635M and be installed per ASTM C636/C636M. All ceiling suspension system components require corrosion-inhibiting treatment. Installation must follow manufacturer's written instructions and ASTM standards, with damaged, stained, bent, or unsuitable ceiling tile and grid components replaced as necessary to provide a complete, secure, and uniform finished ceiling. Materials must be delivered in manufacturer's original unopened containers, stored in dry watertight enclosures, and acclimated for not less than 24 hours at the same temperature and relative humidity as the installation space. Environmental conditions must be maintained at 60–85 degrees Fahrenheit and no more than 70 percent relative humidity for 24 hours before, during, and after installation. The contractor must provide manufacturer's warranty for one year from final acceptance covering defects in materials and workmanship, including sagging, warping, rusting, and grid system failures. Product data for acoustical ceiling systems requires government approval (G classification) and must be submitted per Section 01 33 00 submittal procedures.

View the file

Other files

File Type Posted
RFI 03 response_B422 Breakroom Dimensions.pdf PDF
RFI and Response document (as of 23 Nov 26).pdf PDF
RFI 03 response_B300 BDOC Dimensions.pdf PDF
W50S8R27BA002 0003_Amendment 03.pdf PDF
RFI and Response document (as of 18 Nov 26).pdf PDF
RFI 02 response_attachment_B422 Breakroom 09 65 00.pdf PDF
RFI 02 response_attachment_B300 BDOC 09 68 00.pdf PDF
W50S8R27BA002 0003_Amendment 03 (conformed copy).pdf PDF
RFI 02 response_attachment_B300 BDOC 09 65 00.pdf PDF
Pre-Bid attendance.pdf PDF
Pre-Bid Conference minutes.pdf PDF
Pre-Bid Conference-slides.pptx PPTX presentation
Attachment 01c_B422 Breakroom_Specifications.pdf PDF
W50S8R27BA002 0002_Amendment 02.pdf PDF
RFI and Response document (as of 13 Nov 26).pdf PDF
W50S8R27BA002 0002_Amendment 02 (conformed copy).pdf PDF
Attachment 02c_B300 BDOC_Specifications.pdf PDF
Contractor Access form.pdf PDF
W50S8R27BA002 0001_Amendment 01 (conformed copy).pdf PDF
W50S8R27BA002 0001_Amendment 01.pdf PDF
Attachment 02a_B300 BDOC_SOW.pdf PDF
Exhibit B_Checklist for Bid Bonds.pdf PDF
Attachment 02b_B300 BDOC_Drawings.pdf PDF
Attachment 01a_B422 Breakroom_SOW.pdf PDF
W50S8R27BA002_B422 Breakroom and B300 BDOC.pdf PDF
Exhibit A_Sealed Bid Checklist_Reminders.pdf PDF
Attachment 01b_B422 Breakroom_Drawings.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION 09 51 00

ACOUSTICAL CEILINGS

08/20

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

ASTM INTERNATIONAL (ASTM)

ASTM C635/C635M (2022) Standard Specification for Manufacture, Performance, and Testing of Metal Suspension Systems for Acoustical Tile and Lay-In Panel Ceilings

ASTM C636/C636M (2013) Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-In Panels

ASTM E1264 (2023) Standard Classification for Acoustical Ceiling Products

U.S. DEPARTMENT OF DEFENSE (DOD)

UFC 3-301-01 (2023; with Change 2, 2024) Structural Engineering

1.2 SUBMITTALS

Government approval is required for submittals with a "G" or "S" classification. Submittals not having a "G" or "S" classification are for Contractor Quality Control approval. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:

SD-03 Product Data

Acoustical Ceiling Systems ; G

1.3 DELIVERY, STORAGE. AND HANDLING

Deliver materials to the site in the manufacturer's original unopened containers with brand name and type clearly marked. Carefully handle and store materials in dry, watertight enclosures. Immediately before installation, store acoustical units for not less than 24 hours at the same temperature and relative humidity as the space where they will be installed in order to assure proper temperature and moisture acclimation.

1.4 ENVIRONMENTAL REQUIREMENTS

Maintain a uniform temperature of not less than 60 degrees F nor more than 85 degrees F and a relative humidity of not more than 70 percent for 24 hours before, during, and 24 hours after installation of acoustical units.

1.5 SCHEDULING

Complete and dry interior finish work such as plastering, concrete and terrazzo work before ceiling installation. Complete mechanical, electrical, and other work above the ceiling line; install and start operating heating, ventilating, and air conditioning systems in order to maintain temperature and humidity requirements.

1.6 WARRANTY

Provide manufacturer's warranty to repair or replace defective materials and workmanship including but not limited to, sagging and warping of panels and rusting and of grid systems, for a period of one year from date of final acceptance of the work.

PART 2 PRODUCTS

2.1 SYSTEM DESCRIPTION

Provide acoustical ceiling tile and suspension system components required to restore disturbed ceiling areas and complete the Work as indicated.

Replacement ceiling tile and suspension system components shall match existing in size, profile, material, edge detail, finish, color, texture, and appearance. Coordinate ceiling repairs and restoration with light fixtures, diffusers, monitors, projector removal, and other ceiling penetrations affected by the Work.

2.2 ACOUSTICAL UNITS

Provide replacement acoustical ceiling tile conforming to ASTM E1264 and matching the existing installed ceiling tile in size, thickness, edge detail, texture, color, finish, and appearance. Basis of design is USG Ceilings No. 414, Shadowline Bevel Edge, 3/4 inch thick, 2 foot by 2 foot, Frost ClimaPlus, or approved equal matching existing conditions.

2.3 SUSPENSION SYSTEM

Provide replacement or repaired suspension system components to match the existing ceiling grid in size, profile, material, finish, and appearance.

Conform suspension system components to ASTM C635/C635M and install in accordance with ASTM C636/C636M. Replace bent, damaged, or otherwise unsuitable grid components and restore disturbed ceiling grid areas to a complete, secure, and uniform condition matching adjacent existing construction.

2.4 FINISHES

Use manufacturer's standard textures, patterns and finishes as specified for acoustical units and suspension system members. Treat ceiling suspension system components to inhibit corrosion.

2.5 COLORS AND PATTERNS

Use colors and patterns for acoustical units and suspension system components match existing .

PART 3 EXECUTION

3.1 INSTALLATION

Install acoustical ceiling tile and suspension system components in accordance with the manufacturer’s written instructions and ASTM C636/C636M.

Restore ceiling areas disturbed by the Work to match adjacent existing construction. Replace damaged, stained, bent, or otherwise unsuitable ceiling tile and grid components as required to provide a complete, secure, and uniform finished ceiling. Coordinate ceiling repairs with ceiling-mounted devices, penetrations, and other affected work.

3.1.1

3.2 CLEANING

Following installation, clean dirty or discolored surfaces of acoustical units and leave them free from defects. Remove units that are damaged or improperly installed and provide new units as directed.

[] -- End of Section --

File details come from the government source that posted it. Updated .