This document is a specification for carpeting installation (Section 09 68 00) dated November 2024, establishing technical and performance requirements for carpet materials and installation in federal construction projects.

The specification mandates modular carpet tile products measuring 20 by 20 inches with tufted construction, level-loop pile type, and 100 percent branded nylon continuous filament fibers in solution-dyed configuration. Carpet must contain a minimum of 20 percent recycled content and be free from PFOS/PFOA compounds. Products must meet indoor air quality emissions requirements per CDPH Section 01350 and obtain certification through UL 2818 (GreenGuard) Gold, SCS Global Services Indoor Advantage Gold, or CRI GLP QM. Performance requirements include a Texture Appearance Retention Rating (TARR) of 3.0 or greater per ASTM D7330 or CRI Test Method 103, static control less than 3.5 kV per AATCC 134, minimum 8-pound average tuft bind force per ASTM D1335, and delamination strength of minimum 3.5 lbs/inch per ASTM D3936. Carpet in corridors and exits must achieve minimum critical radiant flux of 0.45 watts per square centimeter per ASTM E648 and comply with flammability standards 16 CFR 1630 or ASTM D2859.

Installation requires manufacturer-approved installers following CRI 104/CRI 105 standards, with concrete substrates at least 90 days old and moisture testing per ASTM F1869 and F2170 confirming levels below 3 lb/1000 sq. ft. or relative humidity below 75 percent. Adhesives and concrete primers must meet VOC content requirements of SCAQMD Rules 1113 and 1168 with minimum 140-degree Fahrenheit flashpoint per ASTM D3278. The contractor must provide manufacturer warranties of minimum ten-year wear coverage, two-year material and workmanship, and ten-year tuft bind and delamination protection, plus three percent extra modular tiles from the same dye lot for future maintenance.

View the file

Other files

File Type Posted
RFI 03 response_B422 Breakroom Dimensions.pdf PDF
RFI and Response document (as of 23 Nov 26).pdf PDF
RFI 03 response_B300 BDOC Dimensions.pdf PDF
W50S8R27BA002 0003_Amendment 03.pdf PDF
RFI and Response document (as of 18 Nov 26).pdf PDF
RFI 02 response_attachment_B422 Breakroom 09 65 00.pdf PDF
W50S8R27BA002 0003_Amendment 03 (conformed copy).pdf PDF
RFI 02 response_attachment_B300 BDOC 09 65 00.pdf PDF
RFI 02 response_attachment_B422 Breakroom 09 51 00.pdf PDF
Pre-Bid attendance.pdf PDF
Pre-Bid Conference minutes.pdf PDF
Pre-Bid Conference-slides.pptx PPTX presentation
Attachment 01c_B422 Breakroom_Specifications.pdf PDF
W50S8R27BA002 0002_Amendment 02.pdf PDF
RFI and Response document (as of 13 Nov 26).pdf PDF
W50S8R27BA002 0002_Amendment 02 (conformed copy).pdf PDF
Attachment 02c_B300 BDOC_Specifications.pdf PDF
Contractor Access form.pdf PDF
W50S8R27BA002 0001_Amendment 01 (conformed copy).pdf PDF
W50S8R27BA002 0001_Amendment 01.pdf PDF
Attachment 02a_B300 BDOC_SOW.pdf PDF
Exhibit B_Checklist for Bid Bonds.pdf PDF
Attachment 02b_B300 BDOC_Drawings.pdf PDF
Attachment 01a_B422 Breakroom_SOW.pdf PDF
W50S8R27BA002_B422 Breakroom and B300 BDOC.pdf PDF
Exhibit A_Sealed Bid Checklist_Reminders.pdf PDF
Attachment 01b_B422 Breakroom_Drawings.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION 09 68 00

CARPETING

11/24

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

AMERICAN ASSOCIATION OF TEXTILE CHEMISTS AND COLORISTS (AATCC)

AATCC 134 (2016) Electrostatic Propensity of Carpets

ASTM INTERNATIONAL (ASTM)

ASTM D1335 (2017; E 2018) Standard Test Method for Tuft Bind of Pile Yarn Floor Coverings

ASTM D3278 (2021) Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus

ASTM D3936 (2021) Standard Test Method for Resistance to Delamination of the Secondary Backing of Pile Yarn Floor Covering

ASTM D7330 (2015) Standard Test Method for Assessment of Surface Appearance Change in Pile Floor Coverings Using Standard Reference Scales

ASTM E648 (2023) Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

ASTM F1869 (2023) Standard Test Method for Measuring Moisture Vapor Emission Rate of Concrete Subfloor Using Anhydrous Calcium Chloride

CALIFORNIA DEPARTMENT OF PUBLIC HEALTH (CDPH)

CDPH SECTION 01350 (2017; Version 1.2) Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources using Environmental Chambers

CARPET AND RUG INSTITUTE (CRI)

CRI 104 (2015) Carpet Installation Standard for Commercial Carpet

CRI GLP QM (2017) Green Label Plus Quality Manual

CRI Test Method 103 (2015) Standard Test Method for the Evaluation of Texture Appearance Retention of Carpet Standards Program

SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD)

SCAQMD Rule 1113 (2016) Architectural Coatings

SCAQMD Rule 1168 (2022) Adhesive and Sealant Applications

UL SOLUTIONS (UL)

UL 2818 (2022) GREENGUARD Certification Program For Chemical Emissions For Building Materials, Finishes And Furnishings

1.2 SUBMITTALS

Government approval is required for submittals with a "G" or "S" classification. Submittals not having a "G" or "S" classification are for Contractor Quality Control approval. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:

SD-02 Shop Drawings

Installation Drawings ; G

SD-03 Product Data

Carpet ; G

Moldings ; G

Indoor Air Quality for Aerosol Adhesives ; S

Indoor Air Quality for Non-Aerosol Adhesives ; S

Indoor Air Quality for Concrete Primer ; S

SD-04 Samples

Carpet ; G

Moldings ; G

SD-08 Manufacturer's Instructions

Surface Preparation

SD-10 Operation and Maintenance Data

Cleaning and Protection

SD-11 Closeout Submittals

Warranty

1.3 CERTIFICATIONS

1.3.1 Indoor Air Quality Certifications

1.3.1.1 Floor Covering Materials

Provide carpetcushion products certified to meet indoor air quality requirements by UL 2818 (GreenGuard) Gold, SCS Global Services Indoor Advantage Gold, CRI GLP QM or provide certification or validation by other third-party program that products meet the requirements of this Section.

Provide current product certification documentation from certification body. When product does not have certification, provide validation that product meets the indoor air quality product requirements cited herein.

1.4 DELIVERY, STORAGE, AND HANDLING

Deliver materials to the site in the manufacturer's original wrappings and packages clearly labeled with the manufacturer's name, brand name, size, dye lot number, and related information. Remove materials from packaging and store them in a clean, dry, well ventilated area protected from damage, soiling, and moisture, and maintain at a temperature above 60 degrees F for 2 days prior to installation. Do not store carpet near materials that may off gas or emit harmful fumes, such as kerosene heaters, fresh paint, or adhesives.

1.5 AMBIENT CONDITIONS

Maintain areas in which carpeting is to be installed at a temperature above 60 degrees F and below 90 degrees F for 2 days before installation, during installation, and for 2 days after installation. Provide temporary ventilation during work of this section. Maintain a minimum temperature of 55 degrees F thereafter for the duration of the contract.

1.6 WARRANTY

Provide manufacturer's standard performance guarantees or warranties including minimum ten year wear warranty, two year material and workmanship and ten year tuft bind and delamination.

PART 2 PRODUCTS

2.1 CARPET

Furnish first quality carpet that is free of visual blemishes, streaks, poorly dyed areas, fuzzing of pile yarn, spots or stains, and other physical and manufacturing defects. Provide carpet materials and treatments as reasonably nonallergenic and free of other recognized health hazards. Provide a static control construction on all grade carpets which gives adequate durability and performance. Submit manufacturer's catalog data and printed documentation stating physical characteristics, durability, resistance to fading, and flame resistance characteristics for each type of carpet material and installation accessory. Submit manufacturer's Product Data for a.) Carpet, b.) Moldings. Also, submit Samples of the following:

a. Carpet: Two "Production Quality" samples 18 by 18 inches of each carpet proposed for use, showing quality, pattern, and color specified

b. Moldings: Two samples of each type minimum 12 inches long c.

]2.1.1 Recycled Content

Carpeting must contain a minimum of 20 percent recycled content. Provide data identifying percentage of recycled content for carpeting .

2.1.2 PFOS/PFOA Requirements

Provide materials free from perfluorooctanesulfonic acid (PFOS) or perfluorooctanoic acid (PFOA).

2.1.3 Indoor Air Quality Requirements

Products must meet emissions requirements of CDPH SECTION 01350 . Provide certification or validation of indoor air quality for carpet indoor air quality for textile composite carpet .

2.1.4 Physical Characteristics for Modular Tile Carpet

2.1.4.1 Carpet Construction

Tufted

2.1.4.2 Type

Modular carpet tile 20 by 20 inch square with 0.15 percent growth/shrink rate in accordance with ISO 2551 .

2.1.4.3 Pile Type

Level-loop

2.1.4.4 Pile Fiber

Commercial 100 percent branded (federally registered trademark) nylon continuous filament .

2.1.4.5

2.1.4.6 Dye Method

Solution dyed

2.1.4.7 Backing Materials

Provide primary backing materials like synthetic material . Provide secondary backing to suit project requirements of those customarily used and accepted by the trade for each type of carpet.

2.1.4.8

2.2 PERFORMANCE REQUIREMENTS

2.2.1 Texture Appearance Retention Rating (TARR)

Provide carpet with a greater than or equal to 3.0 (Heavy) TARR traffic level classification in accordance with ASTM D7330 or CRI Test Method 103 .

2.2.2 Static Control

Provide static control to permanently regulate static buildup to less than

3.5 kV when tested at 20 percent relative humidity and 70 degrees F in accordance with AATCC 134.

2.2.3 Flammability and Critical Radiant Flux Requirements

Comply with 16 CFR 1630 or ASTM D2859. Provide carpet in corridors and exits with a minimum average critical radiant flux of 0.45 watts per square centimeter when tested in accordance with ASTM E648 or NFPA 253 .

2.2.4 Tuft Bind

Comply with ASTM D1335 for tuft bind force required to pull a tuft or loop free from carpet backing with a minimum 8 pound average force for modular carpet tile.

2.2.5

2.2.6

2.2.7 Delamination Strength

Provide delamination ASTM D3936 strength for tufted carpet with a secondary back of minimum 3.5 lbs/inch .

2.2.8

2.3 ADHESIVES AND CONCRETE PRIMER

Comply with applicable regulations regarding toxic and hazardous materials. Provide water resistant, mildew resistant, nonflammable, and nonstaining adhesives and concrete primers for carpet installation as required by the carpet manufacturer. Provide release adhesive for modular tile carpet as recommended by the carpet manufacturer. Provide adhesives flashpoint of minimum 140 degrees F in accordance with ASTM D3278.

Non-aerosol adhesive products used on the interior of the building (defined as inside of the weatherproofing system) must meet either emissions requirements of CDPH SECTION 01350 (limit requirements for either office or classroom spaces regardless of space type) or VOC content requirements of SCAQMD Rule 1168 . Aerosol adhesive products used on the interior of the building (defined as inside of the weatherproofing system) must meet either emissions requirements of CDPH SECTION 01350 (limit requirements for either office or classroom spaces regardless of space type) or VOC content requirements of GS-36. Provide validation of indoor air quality for aerosol adhesives . Provide validation of indoor air quality for non-aerosol adhesives . Concrete primer products used on the interior of the building (defined as inside of the weatherproofing system) must meet either emissions requirements of CDPH SECTION 01350 (limit requirements for either office or classroom spaces regardless of space type) or VOC content requirements of SCAQMD Rule 1113 . Provide validation of indoor air quality for concrete primer .

2.4

2.5 MOLDINGS

Provide carpet moldings where floor covering material changes or carpet edge does not abut a vertical surface. Provide an aluminum molding, pinless clamp-down type, designed for the type of carpet being installed.

Provide natural color anodized

2.7 COLOR, TEXTURE, AND PATTERN

Provide color, texture, and pattern selected by the Government from the manufacturer’s standard options.

PART 3 EXECUTION

3.1 SURFACE PREPARATION

Do not install carpet on surfaces that are unsuitable and will prevent a proper installation. Prepare subfloor in accordance with flooring manufacturer's recommended instructions. Repair holes, cracks, depressions, or rough areas using material recommended by the carpet or adhesive manufacturer. Free floor of any foreign materials and sweep clean. Before beginning work, test subfloor with glue and carpet to determine "open time" and bond. Submit three copies of the manufacturer's printed Installation instructions for the carpet, including Surface Preparation, seaming techniques, and recommended adhesives and tapes.

3.2 MOISTURE AND ALKALINITY TESTS

Test concrete slab for excessive moisture content and excessive alkalinity in accordance with CRI 104 / CRI 105 , ASTM F1869, and ASTM F2170. Submit three copies of reports of Moisture and Alkalinity Tests including content of concrete slab stating date of test, person conducting the test, and the area tested. Perform tests for each 1000 sq. ft. . Perform a minimum of three evenly spaced tests of each installation area. For anhydrous calcium chloride test, confirm substrates have a moisture-vapor-emission rate less than 3 lb of water/1000 sq. ft. . For relative humidity tests confirm substrate relative humidity levels are less than 75 percent.

3.3 PREPARATION OF CONCRETE SUBFLOOR

Do not commence installation of the carpeting until concrete substrate is at least 90 days old. Prepare the concrete surfaces in accordance with the carpet manufacturer's instructions. Match carpet, when required, and adhesives to prevent off-gassing to a type of curing compounds, leveling agents, and concrete sealer.

3.4 INSTALLATION

Perform all work by manufacturer's approved installers. Conduct installation in accordance with the manufacturer's printed instructions and CRI 104 / CRI 105 . Protect edges of carpet meeting hard surface flooring with molding and install in accordance with the molding manufacturer's printed instructions. Follow ventilation, personal protection, and other safety precautions recommended by the adhesive manufacturer. Continue ventilation during installation and for at least 72 hours following installation. Do not permit traffic or movement of furniture or equipment in carpeted area for 24 hours after installation.

Complete other work which would damage the carpet prior to installation of carpet. Submit three copies of Installation Drawings for 1) Carpet, 2) Carpet Cushion, and 3) Moldings indicating areas receiving carpet, carpet types, patterns, direction of pile, location of seams, and locations of edge molding.

Do not install building construction materials that show visual evidence of biological growth.

3.4.2 Modular Tile Installation

Install modular tiles with releasable adhesive and snug joints. Use monolithic installation method. Comply with manufacturer installation instructions for required drying time of releasable adhesive so it sets up properly. Provide accessibility to the subfloor where required. Modular carpet tile on stairs and sloped surfaces must be installed with a more permanent installation method in accordance with the manufacturer's instructions and with manufacturer recommended adhesives for this application. Install broadloom version of modular tile when available from the same manufacturer for use on stairs and sloped surfaces.

3.5 CLEANING AND PROTECTION

Submit three copies of carpet manufacturer's maintenance instructions describing recommended type of cleaning equipment and material, spotting and cleaning methods, and cleaning cycles.

3.5.1 Cleaning

As specified in Section 01 78 00 CLOSEOUT SUBMITTALS. After installation of the carpet, remove debris, scraps, and other foreign matter. Remove soiled spots and adhesive from the face of the carpet with appropriate spot remover. Cut off and remove protruding face yarn. Vacuum carpet clean.

3.5.2 Protection

Protect the installed carpet from soiling and damage with heavy, reinforced, nonstaining kraft paper, plywood, or hardboard sheets. Lap and secure edges of kraft paper protection to provide a continuous cover.

Restrict traffic for at least 48 hours. Remove protective covering when directed by the Contracting Officer.

3.6 REMNANTS

Manage waste as specified in the Waste Management Plan. Provide remnants remaining from the installation, consisting of scrap pieces more than 2 feet in dimension with more than 6 square feet total to the Government .

Remove non-retained scraps from site and recycle appropriately.

3.7 MAINTENANCE

3.7.1 Extra Materials

Provide extra material from same dye lot consisting of uncut modular carpet tiles for future maintenance. Provide a minimum of three percent of total square yards of each carpet type, pattern, and color.

-- End of Section --