Attachment 02b_B300 BDOC_Drawings.pdf
PDF 516 KB Posted
- Attached to
- B422 BREAKROOM, B300 BDOC
- Solicitation number
- W50S8R27BA002
About this file
B300 BDOC Renovation Project - Architectural and Electrical Construction Drawings
This is a set of architectural and electrical design drawings for the B300 Building Dominance Operations Center (BDOC) renovation project at Mansfield-Lahm Air National Guard Base in Mansfield, Ohio, prepared by the 179th Civil Engineering Squadron. The project encompasses selective demolition, wall repair, painting, resilient tile and carpet tile flooring replacement, limited suspended ceiling restoration, and associated electrical and communications pathway modifications to support revised room use and Government-furnished equipment installation.
The scope of work includes: removal and replacement of floor finishes with new resilient tile flooring and cove base in the BDOC and carpet tile in the Battlestaff room; wall preparation and repainting throughout both spaces; removal of the existing BDOC controller desk and associated obsolete floor-fed utility components; removal and disposal of the existing projector screen and mounting components; removal and reinstallation of existing wall-mounted monitors at revised mounting elevations; removal of existing recessed can light fixtures with ceiling surface restoration; suspension of the ceiling grid/tile with limited acoustic ceiling tile replacement; relocation of existing branch circuitry with new flush-mounted receptacles at the BDOC desk wall; provision of communications pathway rough-in and outlet boxes; provision of new recessed receptacles and surface-mounted cable management raceway at the Battlestaff presentation wall; and acoustical sealing at openings. An optional lighting upgrade (Option #1) includes replacement of existing 2x4 light fixtures with dimmable LED fixtures or LED retrofit kits with associated control modifications. The contractor must field-verify existing conditions, coordinate utility interruptions with the Government, and protect adjacent finishes and building systems during construction. Communications cabling, final terminations, and Government-furnished equipment installation shall be performed by others unless noted otherwise.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SCALE:
DATE:
CHECKED:
DRAWN:
PROJ #:
9T
H C
IV
IL
E N
G
IN
EE
R
IN
G
S Q
U
AD
R O
N M
AN
SF
IE
LD
-L
AH
M A
IR
N
AT
IO
N
AL
G U
AR
D
B
AS
E
H
AR
R
IN
G
TO
N
M
EM
O R
IA
L
R O
AD
M
AN
SF
IE
LD
, O H
B3
B D
O C
R
EN
O
VA
TI
O
N
C O
VE
R
S H
EE
T
PBXP272019
CMM
XXX
10/29/26
NTS
G101
B300 BDOC RENOVATION
MANSFIELD LAHM ANG BASE
SITE MAP
NTS
N
PROJECT
LOCATION
VICINITY MAP
NTS
PROJECT
LOCATION
N
INDEX OF DRAWINGS
G101 COVER SHEET
A101 ARCHITECTURAL NOTES
E101 ELECTRICAL NOTES
GENERAL NOTES
Renovate the B300 BDOC and Battlestaff spaces including selective demolition, wall repair, painting, resilient tile flooring replacement, limited suspended ceiling restoration, and associated electrical and communications pathway modifications to support revised room use and Government-furnished equipment.
1. Contractor shall field verify existing conditions and dimensions prior to construction.
2. Contractor shall coordinate required utility interruptions and access requirements with the Government prior to execution.
3. Contractor shall protect adjacent finishes, equipment, and building systems from damage during construction.
4. Patch and restore surfaces disturbed by the work to match adjacent existing conditions where applicable.
5. Communications cabling and final terminations shall be by others unless noted otherwise.
6. Government-furnished equipment shown or referenced on the drawings shall be installed by others unless noted otherwise..
AutoCAD SHX Text
AutoCAD SHX Text
SCALE IN FEET
AutoCAD SHX Text 0 100 200 300 400 500 600 700 800 900 1000
AutoCAD SHX Text
MUSTANG STREET
AutoCAD SHX Text
SABRE AVENUE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GALAXY ROAD
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
MUSTANG STREET
AutoCAD SHX Text
BUCKEYE STREET
AutoCAD SHX Text
179 AW BASE MAP - JULY 2022 EDITION
AutoCAD SHX Text
SABRE AVENUE
AutoCAD SHX Text H
AutoCAD SHX Text
MINUTEMAN AVENUE
AutoCAD SHX Text
MINUTEMAN AVENUE
AutoCAD SHX Text
MINUTEMAN AVENUE
AutoCAD SHX Text
HERCULES AVENUE
AutoCAD SHX Text
HERCULES AVENUE
AutoCAD SHX Text
HERCULES AVENUE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HERCULES AVENUE
AutoCAD SHX Text
ENTRY CIRCLE
AutoCAD SHX Text
ACCESS ROAD
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 10216
AutoCAD SHX Text 10217
AutoCAD SHX Text 10218
SCALE:
DATE:
CHECKED:
DRAWN:
PROJ #:
9T
H C
IV
IL
E N
G
IN
EE
R
IN
G
S Q
U
AD
R O
N M
AN
SF
IE
LD
-L
AH
M A
IR
N
AT
IO
N
AL
G U
AR
D
B
AS
E
H
AR
R
IN
G
TO
N
M
EM
O R
IA
L
R O
AD
M
AN
SF
IE
LD
, O H
B3
B D
O C
R
EN
O
VA
TI
O
N
AR
C
H
IT
EC
TU
R
AL
N O
TE
S
PBXP272019
CMM
XXX
10/29/26
NTS
A101
CODED NOTES#
1. Area of renovation.
2. Remove existing floor finish as required, prepare substrate, furnish and install new resilient tile flooring and cove base in the BDOC.
3. Prepare and repaint walls throughout
4. Remove existing BDOC controller desk and associated obsolete floor-fed utility components. Refer to E101.
5. Existing communications floor penetration to remain;
coordinate capping and protection with project requirements.
6. Government-furnished controller desk footprint shown for reference; final installation by others.
7. Remove lower 48 inches of wall finish materials and provide new gypsum wallboard, finishing, and preparation for paint as indicated.
8. Remove and dispose of existing projector screen and associated mounting components.
9. Restore suspended ceiling grid/tile and provide limited replacement ACT as required to complete the work.
10. Remove and reinstall existing wall-mounted monitors and associated mounting hardware at revised mounting elevation as indicated.
11. Remove existing floor finish as required, prepare substrate, furnish and install new carpet tile flooring and cove base in the Battlestaff room.
12. Remove existing recessed can light fixtures and restore affected ceiling surfaces and finishes to match adjacent conditions.
13. Provide acoustical sealing at openings
AutoCAD SHX Text
BDOC
AutoCAD SHX Text
BATTLE STAFF
AutoCAD SHX Text
CLOS.
AutoCAD SHX Text
COMM.
AutoCAD SHX Text
WOMENS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
D D D
D
S
S S
SCALE:
DATE:
CHECKED:
DRAWN:
PROJ #:
9T
H C
IV
IL
E N
G
IN
EE
R
IN
G
S Q
U
AD
R O
N M
AN
SF
IE
LD
-L
AH
M A
IR
N
AT
IO
N
AL
G U
AR
D
B
AS
E
H
AR
R
IN
G
TO
N
M
EM
O R
IA
L
R O
AD
M
AN
SF
IE
LD
, O H
B3
B D
O C
R
EN
O
VA
TI
O
N
EL
EC
TR
IC
AL
N
O
TE
S
PBXP272019
CMM
XXX
10/29/26
NTS
E101
CODED NOTES#
1. Remove existing floor-fed utility components associated with the existing BDOC controller desk arrangement, including junction box, exposed whips, and miscellaneous devices no longer required.
2. Relocate existing branch circuitry and provide new flush-mounted receptacles at the BDOC desk wall as indicated.
3. Provide communications pathway rough-in and outlet boxes within finished wall surfaces at the BDOC desk wall as indicated. Communications cabling and terminations shall be by others unless noted otherwise.
4. Existing communications floor penetration to remain, coordinate capping and protection with project requirements. Coordinate with A101.
5. Provide one new recessed receptacle at the Battlestaff presentation wall for Government-furnished monitor.
6. Provide surface-mounted cable management raceway at the Battlestaff presentation wall for HDMI and associated low-voltage cabling as indicated.
7. Coordinate exact device locations with Government prior to rough-in.
8. Final connection of Government-furnished desks, monitor, UPS units, and user equipment shall be by others unless noted otherwise.
9. Remove and reinstall existing wall-mounted monitors and associated mounting hardware at revised mounting elevation as indicated.
10. Remove existing recessed can light fixtures and modify associated switching/circuitry as required to leave remaining lighting safe and operational.
11. Option #1: Replace existing 2x4 light fixtures with dimmable LED fixtures or LED retrofit kits and modify associated lighting controls, switching, and circuitry as required.
AutoCAD SHX Text
BDOC
AutoCAD SHX Text
BATTLE STAFF
AutoCAD SHX Text
CLOS.
AutoCAD SHX Text
COMM.
AutoCAD SHX Text
WOMENS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
| Sheets and Views |
| PBXP272019 - Drawings-Cover |
| PBXP272019 - Drawings-A101 |
| PBXP272019 - Drawings-E101 |
File details come from the government source that posted it. Updated .