ATTACHMENT 7B - A-601 - Arch Door_Window Schedules.pdf

PDF 200 KB Posted

Attached to
ADAL Civil Engineering, Buildings 151 & 119
Solicitation number
W50S8Q-20-B-0004
Issued by

About this file

This document provides details for a federal construction solicitation issued by the 178th Wing Contracting Office at Springfield Air National Guard Base. The solicitation is for Project No. WAAR152202 to remodel and add to civil engineering Building 151 and remodel Buildings 119a and 119b at the base. The work includes mechanical, electrical, plumbing, communications, security, and finishes. The construction duration is 360 calendar days with adequate time for inspection and punch list. The solicitation is set aside as an 8(a) competitive small business opportunity. The North American Industry Classification code is 236220 with a size standard of $39.5 million average annual revenue. The estimated value is between $5-10 million. A pre-bid conference is scheduled for September 1, 2020 at 10 a.m. with registration and base access requirements in the solicitation. Bids are due September 24, 2020 at 10 a.m. Interested contractors must register in the System for Award Management. The solicitation and plans are available on the Federal Business Opportunities website. Any questions should be directed to the listed contracting specialist by email.

View the file

Other files

File Type Posted
BID ABSTRACT 20-B-0004.pdf PDF
Sign-In Bid Opening 20-B-0004.pdf PDF
W50S8Q-20-B-0004-0003 ADAL CE SPANGB.pdf PDF
ADAL Amendment 0002.pdf PDF
ATTACHMENT 7A - Questions_ Answers 2.docx DOCX document
ATTACHMENT 7C - Typical Existing Restroom Elevations.pdf PDF
ATTACHMENT 7D - B119 Mezz Location.pdf PDF
ATTACHMENT 6B - A0-5 Layout.pdf PDF
Site Visit SignIn Sheet 01 Sept 2020 (1).pdf PDF
20-B-0004 ATTACHMENT 6D - Arch Specs pg 12 08 71 00.pdf PDF
ATTACHMENT 6A - Questions Answers.docx DOCX document
20-B-0004 Site Visit SignIn Sheet 01 Sept 2020 (4).pdf PDF
ADAL Amemdment 0001.pdf PDF
20-B-0004 ATTACHMENT 6C - A-104 Architectural Roof Plan.pdf PDF
20-B-0004 Site Visit MFR.docx DOCX document
W50S8Q-20-B-0004 ADAL CE SPANGB 25AUG.pdf PDF
ATTACHMENT 3B - DRAWINGS (CIVIL SET).pdf PDF
ATTACHMENT 3J - CORRECTIONS (A102 A104 A601 AD102 F501).pdf PDF
ATTACHMENT 4 - Base Entry Request.pdf PDF
JA for Brand Names -Advantor Monaco Lochinvar-redo 18 Aug 20.pdf PDF
ATTACHMENT 3H - DRAWINGS (STRUCT SET).pdf PDF
ATTACHMENT 3C - DRAWINGS (ELECTRICAL SET).pdf PDF
ATTACHMENT 2A - SPEC BOOK VOL I.pdf PDF
ATTACHMENT 3A - DRAWINGS (ARCH SET).pdf PDF
ATTACHMENT 3I - DRAWINGS (TECHNOLOGY SET).pdf PDF
ATTACHMENT 1 - SUMMARY OF WORK.docx DOCX document
ATTACHMENT 3D - DRAWINGS (FIRE PROTECTION SET).pdf PDF
ATTACHMENT 5 - RFI.doc DOC document
ATTACHMENT 2B - SPEC BOOK VOL II.pdf PDF
ATTACHMENT 3G - DRAWINGS (PLUMBING SET).pdf PDF
ATTACHMENT 3F - DRAWINGS (MECHANICAL SET).pdf PDF
ATTACHMENT 3E - DRAWINGS (GEN SET).pdf PDF
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

F1

4"

SEE SCHEDULE

2"2"

W

AL

LS

2"

A T

N O

N -M

AS

O

N R

Y

F2 F3

W

AL

LS

2"

A T

N O

N -M

AS

O

N R

Y

W A L

LS

2"

A T

N O

N -M

AS

O

N R

Y

F4

2'

0"

F F[2]

NOTE: FOR DOOR WIDTH AND HEIGHT

SEE DOOR SCHEDULE

GCLEAR

TEMPERED

GLASS,

U.N.O.

5" 5"

5" 2'

LAMINATED,

INSULATED

GLAZING

W1

R.O. 4' - 0"

R .O

. 6

3' - 11"

6'

7"

ALUMINUM

WINDOW

2'

4"

2'

0"

EXISTING DOOR FRAME

LAMINATED, INSULATED GLAZING

V.I.F.

3'

1/

4" 2'

8"

6'

3/

4" 6'

4"

2'

1/

4"

3' - 2 1/2" 3' - 1 1/4" 3' - 1" 3' - 2 1/2" 7 1/2"

2' - 9 1/2" 3' - 1 1/4" 3' - 1 1/4" 2' - 9 1/2" 7 1/2"

3' - 2 1/2" 3' - 1" 3' - 1 1/4" 3' - 2 1/2"

4'

1/

2" 2'

0"

7'

1/

4"

2' - 9 1/2"3' - 1 1/4"3' - 1 1/4"2' - 9 1/2"

11' - 9 1/2"

4'

1/

2" 2'

0"

7'

1/

4"

/4

EQ EQ

8' - 5 1/2"

4'

0" 6'

4"

2'

9"

EQ EQ

8' - 5 1/2" 2'

9"

6'

4" 4'

0"

CHKD:

DRWN:

PROJ:

DESN:

A

B

C

D

E

F

2 3 4 5 6 7

Bar measures 1 inch, otherwise drawing is not to scale

C op yr ig ht : T et ra

T ec h

2' 4' 8'

SCALE: 1/4" = 1'-0"

9/

/2

1 :

:4

AM

C :\U se rs

\ja so n.

hu ns uc ke r\D oc um en ts

\A -S

PR

IN

G

FI

EL

D

A N

G B

LD

G

_v

_j as on

.h un su ck er .rv t

200-11652-18005

J. HUNSUCKER

T. HOURIGAN

Q. BIAGI

A-601

SP

R

IN

G

FI

EL

D -B

EC

KL

EY

A

N G

B, O

H

IO

A N

G

AD

AL

C

IV

IL

E

N G

IN

EE

R

IN

G B

U

IL

D

IN

G S

W

AA

R

AR

C

H

IT

EC

TU

R

AL

D O

O R

AN

D

W

IN

D O

W S

C H

ED

U

LE

S

AN

D

D

ET

AI

LS

WINDOW SCHEDULE

MARK

R.O. FRAME GLAZING DETAILS

COMMENTSWIDTH HEIGHT FINISH MATERIAL TYPE THICKNESS HEAD JAMB SILL

W1 4' - 0" 6' - 8" PRE-FINISHED ALUMINUM CLR. 1 3/4" 13/A-501 12/A-501 11/A-501 SEE NOTES BELOW

SCALE: 1/4" = 1'-0"

FRAME TYPES

SCALE: 1/4" = 1'-0"

DOOR TYPES

SCALE: 1/4" = 1'-0"

WINDOW TYPES

NOTES:

1. VERIFY ALL FIXED WINDOWS FIT WITHIN MASONRY COURSING AS DESIGNED.

2. FOR EXISTING ALUMINUM STOREFRONT, FRAMING AND CONFIGURATION SHALL REMAIN.

3. THERMALLY INSULATED ALUMINUM FRAME, LAMINATED, INSULATED EXTERIOR LITE, DUAL GLAZING.

4. WINDOWS IN PRIMARY GATHERING PORTION OF BUILDING (ALL WINDOW REPLACEMENT) ARE REQUIRED TO MEET ATFP STANDARDS REFERENCED IN UFC 4-010-01. REFER TO SPECIFICATION SECTION 08 41 13, FOR

GLAZING SPECIFICATION SECTION 08 81 00.

5. WINDOW FRAMES AND CONNECTIONS SHALL RESIST BLAST LOADING IN ACCORDANCE WITH ASTM F1642 WITH

HAZARD RATINGS IN ACCORDANCE WITH ASTM F2912.

6. ALL LAMINATED GLAZING AND FRAME BIT SHALL FOLLOW ASTM F2248 REQUIREMENTS.

7. TINT GLAZING FOR LOW GLARE.

NOTES:

1. REFER TO SPECIFICATION SECTION 08 71 00 FOR DOOR HARDWARE SETS.

2. DOORS IN PRIMARY GATHERING PORTION OF THE BUILDING ON EXTERIOR WALLS ARE REQUIRED TO MEET ATFP STANDARDS REFERENCED IN UFC 4-010-01. REFER TO SPECIFICATION SECTIONS 08 11 13.

3. ALL DOOR LAMINATED GLAZING SHALL BE IN ACCORDANCE WITH ASTM F2248.

4. EGRESS DOORS WILL HAVE EXIT (PANIC) HARDWARE ONLY. NO EXTERNAL HARDWARE REQUIRED.

5. ALL EXISTING DOORS AND FRAMES TO BE PAINTED.

6. INCLUDE DOOR, SEALS, HINGES, FRAMES, AND THRESHOLD TESTED TO TO ASTM E90 TO CALCULATE THE STC IN ACCORDANCE WITH ASTM E413 TO ACHIEVE STC 50 DOOR ASSEMBLY. DOOR SHALL HAVE DROP THRESHOLD.

DOOR SHALL HAVE LIFT HINGE OPERATION AND SHALL BE TAMPER RESISTANT.

SCALE: 1/4" = 1'-0"A-601

SOUTH CURTAIN WALL

SYSTEM

SCALE: 1/4" = 1'-0"A-601

2 INTERIOR STOREFRONT

SCALE: 1/4" = 1'-0"A-601

3 EAST STOREFRONT

SCALE: 1/4" = 1'-0"A-601

4 WEST STOREFRONT

NOTES:

1. V.I.F. ALL DIMENSIONS FOR EXISTING STOREFRONT AND CURTAIN WALL SYSTEMS.

2. STOREFRONT AND CURTAIN WALL SYSTEM FRAMES TO REMAIN, REMOVE EXISTING GLAZING AND INSTALL LAMINATED, INSULATED GLAZING AND NEW FRAME BITE IN

ACCORDANCE WITH ASTM F2248.

3. EXISTING DIMENSIONS ARE PROVIDED FOR REFERENCE ONLY, CONTRACTOR REQUIRED TO VERIFIY DIMENSIONS IN FIELD.

DOOR SCHEDULE - BUILDING 151

NO.

DOOR FRAME DETAILS

HARDWARE COMMENTS

SIZE

MATERIAL FINISH TYPE MATERIAL FINISH HEAD JAMB SILLTYPE WIDTH HEIGHT THICKNESS

2 6' - 0" 7' - 0" 0' - 0 3/4" 6.0 PANIC DEVICE, EXISTING DOOR / FRAME, NEW HARDWARE 4B 3' - 0" 7' - 0" 0' - 1 3/4" 4.0 PANIC DEVICE, EXISTING DOOR / FRAME, NEW HARDWARE 5B 3' - 0" 7' - 0" 0' - 1 3/4" 4.0 PANIC DEVICE, EXISTING DOOR / FRAME, NEW HARDWARE

6 F(2) 3' - 0" 7' - 0" 0' - 1 3/4" HM P-1 F3 HM P-1 3/A-501 2/A-501 1/A-501 3.0

19 G 3' - 0" 7' - 0" 0' - 1 3/4" HM P-1 F2 HM P-1 3/A-501 2/A-501 1/A-501 2.0

22 G 3' - 0" 7' - 0" 0' - 1 3/4" HM P-1 F1 HM P-1 10/A-501 9/A-501 8/A-501 2.0

30 G 3' - 0" 7' - 0" 0' - 1 3/4" HM P-1 F2 HM P-1 3/A-501 2/A-501 1/A-501 2.0

33 G 3' - 0" 7' - 0" 0' - 1 3/4" HM P-1 F2 HM P-1 3/A-501 2/A-501 1/A-501 2.0

38 F 3' - 0" 7' - 0" 0' - 1 3/4" HM P-1 F2 HM P-1 3/A-501 2/A-501 1/A-501 11.0 ACOUSTICAL DOOR ASSEMBLY, NOTE 6

39 G 3' - 0" 7' - 0" 0' - 1 3/4" HM P-1 F2 HM P-1 3/A-501 2/A-501 1/A-501 2.0

40 G 3' - 0" 7' - 0" 0' - 1 3/4" HM P-1 F2 HM P-1 3/A-501 2/A-501 1/A-501 2.0

41A F 3' - 0" 7' - 0" 0' - 1 3/4" HM P-1 F2 HM P-1 3/A-501 2/A-501 1/A-501 2.0

41B G 3' - 0" 7' - 0" 0' - 1 3/4" HM P-1 F4 HM P-1 10/A-501 9/A-501 8/A-501 9.0 PANIC DEVICE, LAMINATED INSULATED GLAZING AT HALF LITE 42 3' - 0" 7' - 0" 0' - 1 3/4" 9.0 PANIC DEVICE, EXISTING DOOR / FRAME, NEW HARDWARE

54 G 3' - 0" 7' - 0" 0' - 1 3/4" HM P-1 F2 HM P-1 3/A-501 2/A-501 1/A-501 2.0

55 G 3' - 0" 7' - 0" 0' - 1 3/4" HM P-1 F2 HM P-1 3/A-501 2/A-501 1/A-501 2.0

56 G 3' - 0" 7' - 0" 0' - 1 3/4" HM P-1 F2 HM P-1 3/A-501 2/A-501 1/A-501 2.0

61 3' - 0" 7' - 0" 0' - 1 3/4" 8.0 EXISTING DOOR / FRAME, NEW HARDWARE

63 3' - 0" 7' - 0" 0' - 1 3/4" 1.0 EXISTING DOOR / FRAME, NEW HARDWARE

64A 3' - 0" 7' - 0" 0' - 1 3/4" 4.0 EXISTING DOOR / FRAME, NEW HARDWARE

65 3' - 0" 7' - 0" 0' - 1 3/4" 7.0 EXISTING DOOR / FRAME, NEW HARDWARE

66 G 3' - 0" 7' - 0" 0' - 1 3/4" HM P-1 F1 HM P-1 6/A-501 5/A-501 4/A-501 8.0

71B 3' - 0" 7' - 0" 0' - 1 3/4" 4.0 EXISTING DOOR / FRAME, NEW HARDWARE

72B 3' - 0" 7' - 0" 0' - 1 3/4" 4.0 EXISTING DOOR / FRAME, NEW HARDWARE

75 F 3' - 0" 7' - 0" 0' - 1 3/4" HM P-1 F1 HM P-1 6/A-501 5/A-501 4/A-501 2.0

76A 3' - 0" 7' - 0" 0' - 1 3/4" 4.0 EXISTING DOOR / FRAME, NEW HARDWARE

76B 3' - 0" 7' - 0" 0' - 1 3/4" 4.0 EXISTING DOOR / FRAME, NEW HARDWARE

77B 3' - 0" 7' - 0" 0' - 1 3/4" 9.0 PANIC DEVICE, EXISTING DOOR / FRAME, NEW HARDWARE

M

AR

K D

AT

E

D E S

C R

IP

T I

O N

BY

1 2 /1

3/

TY

P E

B -3

S U

BM

IT

TA

L

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

EX.

Sheets
A-601 - ARCHITECTURAL DOOR AND WINDOW SCHEDULES AND DETAILS

File details come from the government source that posted it. Updated .