ATTACHMENT 3D - DRAWINGS (FIRE PROTECTION SET).pdf
PDF 2 MB Posted
- Attached to
- ADAL Civil Engineering, Buildings 151 & 119
- Solicitation number
- W50S8Q-20-B-0004
- Issued by
-
Department of the Army National Guard
About this file
This document provides details for a federal solicitation seeking construction services. The Springfield ANGB Contracting Office is soliciting offers for Project No. WAAR152202, which includes remodeling Buildings 151 and 119A/B at the Springfield Air National Guard Base in Ohio. The project scope consists of mechanical, electrical, plumbing, communications, security and finish work upgrades to Building 151, as well as remodeling of Buildings 119A/B including finishes, mechanical, plumbing and electrical systems. The total contract duration is 360 calendar days with a Notice to Proceed. The NAICS code is 236220 and the size standard is $39.5M average annual revenue. The estimated contract value is between $5-10M. The pre-bid conference is scheduled for September 1, 2020 and bids are due September 24, 2020. The solicitation is designated as an 8(a) small business set-aside and is available through the SAM website. Interested parties must register in SAM to access the solicitation and plans.
View the file
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FIRE PROTECTION SYMBOLS:
FIRE DEPARTMENT CONNECTION
ORIFICE
FLOW SWITCH
ALARM BELL
ISOLATION VALVE
GATE VALVE
PRESSURE GAUGE
CHECK VALVE
VALVE SUPERVISION/TAMPER
SWITCH
STRAINER
T
PIPE DROP
PIPE RISE
STRAINER
FIRE PROTECTION
GROUP PATTERN LEGEND:
LIGHT HAZARD
ORDINARY HAZARD GROUP 1
ORDINARY HAZARD GROUP 2
FIRE ALARM CONTROL PANEL
FIRE ALARM SYMBOLS
FIRE ALARM PULL STATION
FIRE ALARM ANNUNCIATOR PANEL
FIRE ALARM HORN
CONTROL MODULE
FIRE ALARM SPEAKER
FIRE ALARM HORN/STROBE, (##) IS CANDELA RATING
FIRE ALARM SPEAKER/STROBE, (##) IS CANDELA RATING
FIRE ALARM STROBE, (##) IS CANDELA RATING
INTELLIGENT PHOTOELECTRIC SMOKE DETECTOR
INTELLIGENT 135ºF FIXED & RATE OF RISE HEAT DETECTOR
(15ºF/M), (20ºF/M), UNLESS NOTED ON DRAWINGS
INTELLIGENT PHOTOELECTRIC DUCT SMOKE DETECTOR
CEILING MOUNTED FIRE ALARM STROBE,
(##) IS CANDELA RATING
CEILING MOUNTED FIRE ALARM SPEAKER/STROBE,
(##) IS CANDELA RATING
FLOW SWITCH FOR SPRINKLER SYSTEM
SUPERVISORY FLOW ALARM, NORMALLY OPEN DRY
CONTACTS FOR FIRE ALARM INTERFACE,
FURNISHED BY MC, WIRED BY EC.
MONITOR MODULE
REMOTE TEST SWITCH WITH INDICATOR
MONITOR SWITCH (TAMPER SWITCH) FOR
SPRINKLER SYSTEM SUPERVISORY TROUBLE
NOTIFICATION, NORMALLY OPEN DRY CONTACTS
FOR FIRE ALARM INTERFACE, FURNISHED BY MC,
WIRED BY EC.
FIRE ALARM TRANSMITTER PANEL
H
S
H
S
H
DS
S
H
MM
CM
FS
TS
RTS/I
CEILING MOUNTED FIRE ALARM HORN
FACP
FAAP
EWS EARLY WARNING SMOKE DETECTION SYSTEM
FTP
MASS NOTIFICATION SYMBOLS
FMCP FIRE & MASS NOTIFICATION CONTROL PANEL
M
MASS NOTIFICATION SPEAKER/STROBE, WALL MOUNTED
(#) IS CANDELA RATING
M MASS NOTIFICATION SPEAKER, WALL MOUNTED
M
MASS NOTIFICATION SPEAKER/STROBE, CEILING
MOUNTED (#) IS CANDELA RATING
M MASS NOTIFICATION STROBE, WALL MOUNTED
LOC LOCAL OPERATING CONSOLE
FIRE ALARM/MASS NOTIFICATION
LINE TYPE KEY
EXISTING TO BE REMOVED BY THIS
CONTRACTOR (DARK DASHED LINE)
EXISTING TO REMAIN WORK
(THIN SOLID LINE)
NEW WORK BY THIS CONTRACTOR
(DARK SOLID LINE)
NEW WORK UNDER FLOOR BY
THIS CONTRACTOR
SITE UNDERGROUND ELECTRICFA
SITE REMOVED UNDERGROUND
ELECTRIC
//FA//
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
/5
/2
:2
:1
A
M C
R e v it L o c a l\4
-1
.0
-1
-P
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
RMM
RMM
JR
F-001
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
S Y
M B
O L
S
A B
B R
E V
IA
T
IO
N
S
N O
T E
S A
N D
D E
T A
IL
S
11. GENERAL NOTES APPLY UNLESS NOTED OTHERWISE
10. NOMINAL FINISHED FLOOR ELEVATION = 100.0 FT = 707.46 FT ASL
9. SEQUENCE OF WORK AND/OR PLACE OF COMMENCEMENT OF WORK SHALL BE
APPROVED PRIOR TO WORK BEING STARTED. SCHEDULED SHUTDOWNS SHALL BE CLOSELY
COORDINATED WITH EXISTING OPERATIONS.
8. VERIFY ALL EQUIPMENT LOCATIONS AND PIPE ROUTING WITH OWNER PRIOR TO INSTALLATION.
7. TEMPORARILY PATCH ALL ROOF OPENINGS WATERTIGHT UNTIL FINAL CLOSURE CAN BE MADE.
6. ALL NEW AND EXISTING ROOFING SYSTEMS SHALL BE PROTECTED FROM DAMAGE DURING
CONSTRUCTION ACTIVITIES.
5. ACCURATE AND LEGIBLE RECORD (AS-BUILT) DRAWINGS SHALL BE MAINTAINED AT THE JOB SITE, AND BE SUBMITTED PRIOR TO FINAL PAYMENT.
4. ANY AND ALL INFORMATION SHOWN ON THESE DRAWINGS WITH RESPECT TO
EXISTING STRUCTURES, UTILITIES, AND MECHANICAL SYSTEMS, IS AS EXACT AS
COULD BE SECURED. THE INFORMATION IS NOT WARRANTED NOR GUARANTEED
ACCURATE, FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO PROCEEDING WITH WORK.
3. ELEVATION OF PIPING INDICATED ON THESE DRAWINGS ARE TO BE USED AS GUIDELINES TO
ASSIST WITH INSTALLATIONS. MINOR CHANGES TO THESE ELEVATIONS MAY BE NECESSARY TO
ELIMINATE UNFORESEEN INTERFERENCES. ANY CHANGE IN ELEVATION SHALL BE APPROVED...
2. THESE DRAWINGS ARE DESIGN DRAWINGS AND ARE DIAGRAMMATIC, THEY MAY NOT
SHOW ALL PHYSICAL ARRANGEMENTS, OFFSETS, BENDS, OR ELBOWS WHICH MAY
BE REQUIRED FOR PROPER INSTALLATION OF VARIOUS MATERIALS, EQUIPMENT, AND PIPING
SYSTEMS IN ALLOTTED SPACES. EXAMINE THESE AND OTHER AVAILABLE DRAWINGS TO DETERMINE
SPACE LIMITATIONS AND INTERFERENCES. MAKE ANY MINOR CHANGES IN LOCATIONS OF
EQUIPMENT, AND PIPING FROM THAT SHOWN ON DRAWINGS AND FOR ALL PHYSICAL DETAILS
REQUIRED FOR INSTALLATION. COST FOR ADAPTING WORK TO JOB SITE CONDITIONS SHALL NOT BE
CONSIDERED AS BASIS OF AN EXTRA COST TO CONTRACT.
1. ABBREVIATIONS INDICATED HERE AND NOT USED IN THE CONTRACT DOCUMENTS DO NOT APPLY
TO THIS PROJECT. ADDITIONAL ABBREVIATIONS MAY BE INDICATED IN THE CONTRACT...
GENERAL NOTES:
FLOW GPM: 1424 GPM
RESIDUAL PRESSURE: 20 PSI
STATC PRESSURE: 52 PSI
HYD. OUTLET ELEV.: 20" OFF FINISHED GRADE
TEST HYDRANTS NW AND SW CORNERS OF B151
LOCATION: B151
DATE OF TEST: 10/11/2017
FIRE PROTECTION DESIGN / INSTALLATION CONTRACTOR SHALL CONDUCT SEPARATE WATER
FLOW TEST AND USE RESULTS IN HYDRAULIC CALCULATIONS.
NOTE: INFORMATION SHOW FOR BID ONLY, NOT FOR DESIGN.
WATER SUPPLY FLOW BASES FOR BID:
WC WATER CLOSET
NPSHA NPSH AVAILABLE W WATTS OR WIDTH
NPSH NET POSITIVE SUCTION HEAD VTR VENT THROUGH ROOF
EWC ELECTRIC WATER COOLER NOM NOMINAL VLV VALVE
ETR EXISTING TO REMAIN NO NORMALLY OPEN VFD VARIABLE FREQUENCY DRIVE
ET EXPANSION TANK NIC NOT IN CONTRACT V VOLTS OR VENT
ESEW EMERGENCY SHOWER AND EYE/FACE WASH NHC NO-HUB COUPLING UV ULTRAVIOLET
EQPT EQUIPMENT NH NO-HUB UR URINAL
ELEC ELECTRIC NG NATURAL GAS UNO UNLESS NOTED OTHERWISE
EL ELEVATION NFPA NATIONAL FIRE PROTECTION ASSOCIATION UGD UNDERGROUND
EFF EFFICIENCY NEMA NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION UFC UNIFIED FACILITIES CRITERIA
EEW EMERGENCY EYE/FACE WASH NC NORMALLY CLOSED TYP TYPICAL
E EXISTING NA NOT APPLICABLE TH THREADED
DWV DRAIN, WASTE, AND VENT MTL MATERIAL TFB TO FLOOR BELOW
DWG DRAWING MSS MANUFACTURERS STANDARDIZATION SOCIETY TFA TO FLOOR ABOVE
DN DOWN MOCP MINIMUM OVER CURRENT PROTECTION TEMP TEMPERATURE
DISCH DISCHARGE MMBH MILLION BTU PER HOUR TDS TOTAL DISSOLVED SOLIDS
DIM DIMENSION MIN MINIMUM TDH TOTAL DEVELOPED HEAD
DIA DIAMETER MFR MANUFACTURER SW SOCKET WELD
DI DUCTILE IRON MCC MOTOR CONTROL CENTER SV SOLVENT WELD
DFD DEPARTMENT OF DEFENSE MCA MINIMUM CIRCUIT AMPACITY STL STEEL
DEMO DEMOLISH MC MECHANICAL COUPLING STD STANDARD
DEG DEGREE MBH THOUSAND BTU PER HOUR SS STAINLESS STEEL
DCVA DOUBLE CHECK VALVE ASSEMBLY BPD MAX MAXIMUM SRV SAFETY RELIEF VALVE
DBA DECIBELS, BAND A MAWP MAXIMUM ALLOWABLE WORKING PRESSURE SR SERVICE SINK
CU COPPER OR CUBIC MADP MAXIMUM ALLOWABLE DIFFERENTIAL PRESSURE SQ SQUARE
CTW CLOSE TO WALL LPG LIQUIFIED PETROLEUM GAS SPEC SPECIFICATIONS
CTCLM CLOSE TO COLUMN LIN LINEAR SP STATIC PRESSURE
CTCLG CLOSE TO CEILING LCO LINE CLEANOUT SMLS SEAMLESS
CS CARBON STEEL LB POUNDS SK SINK
CRA CONCRETE REACTION ANCHOR L LENGTH OR LAVATORY SHT SHEET
COR CONTRACTING OFFICER'S REPRESENTATIVE IPC INTERNATIONAL PLUMBING CODE SHF SOCKET HEAT FUSION
COMP COMPRESSOR INWC INCHES WATER COLUMN PRESSURE SH SHOWER
CL CENTERLINE INHG INCHES MERCURY PRESSURE SDR STANDARD DIMENSION RATIO
CISPI CAST IRON SOIL PIPE INSTITUTE IN INCH SD SOLDER
CI CAST IRON IE INVERT ELEVATION SCO STACK CLEANOUT
BZ BRONZE ID INSIDE DIAMETER SCH SCHEDULE
BW BUTTWELD IBNLT INCLUDING BUT NOT LIMITED TO RPZ REDUCED PRESSURE ZONE BPD
BTW BOOTWASH IAW IN ACCORDANCE WITH RPM REVOLUTIONS PER MINUTE
BTU BRITISH THERMAL UNIT HZ HERTZ REF REFERENCE
BS BLACK (MILD) STEEL HX HEAT EXCHANGER RCP REINFORCED CONCRETE PIPE
BRZ BRONZE HP HORSEPOWER QTY QUANTITY
BRS BRASS HOA HAND-OFF-AUTO PVC POLYVINYL CHLORIDE
BR BRAZE HDB HYDROSTATIC DESIGN BASIS PSIG PSI GAGE
BPD BACKFLOW PREVENTION DEVICE HC HOSE CONNECTION PSID PSI DIFFERENTIAL
BO BID OPTION H HEIGHT PSIA PSI ABSOLUTE
BLDG BUILDING GS GALVANIZED STEEL PSI POUNDS PER SQUARE INCH
BHF BUTT HEAT FUSION GR GROOVED PREDV PRESSURE REDUCING VALVE
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS GPM GALLONS PER MINUTE PPH POUND PER HOUR ASSE AMERICAN SOCIETY OF SANITARY ENGINEERING GBS GASKETED BELL AND SPIGOT PP POLYPROPYLENE
ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS GAL GAUGE PL PLACES
ASL ABOVE SEA LEVEL GAL GALLON PH PHASE
ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS FTWC FEET WATER COLUMN PRESSURE PE POLYETHYLENE
APPROX APPROXIMATELY FT FEET PDI PLUMBING DEVELOPMENT INSTITUTE
ANG AIR NATIONAL GUARD FS FLOOR SINK PD PRESSURE DROP/DIFFERENTIAL
ALUM ALUMINIUM FPM FEET PER MINUTE P PRESSURE
AHJ AUTHORITY HAVING JURISDICTION FLOW FLOW OR FLOWRATE PCN PLANT CONTROL NETWORK
AGD ABOVEGROUND FLA FULL LOAD AMPS OFOI OWNER FURNISHED, OWNER INSTALLED
AFF ABOVE FINISHED FLOOR FD FLOOR DRAIN OFCI OWNER FURNISHED, CONTRACTOR INSTALLED
ABI ALTERNATE BID ITEM FCO FLOOR CLEANOUT OD OUTSIDE DIAMETER
A AMPS F FAHRENHEIT NPSHR NPSH REQUIRED
ABBREVIATIONS
EXTRA 500 (1900) 500 (1900) 90
ORDINARY 250 (950) 500 (1900) 60
LIGHT 250 (950) 500 (1900) 60
CEILING HEIGHT 60 FT.
OR LESS (18.3m)
CEILING HEIGHT
GREATER THAN 60 FT.
(18.3m)
HAZARD
CLASIFICATION
HOSE DEMAND, gpm (lpm)
DURATION, MIN
Table 9-4 Hose Stream Demand and Duration
K-factor 11.2 (160)
11.2 (160)
11.2 (160)
11.2 (160)
11.2 (160)
11.2 (160)
25.2 (360)
N/A
EXTRA
DESIGN
.3/2500 (12/230)
.3/3500 (12/330)
.3/3600 (12/340)
.3/4600 (12/430)
.5/3000 (20/280)
.5/4000 (20/370)
12.0 @ 7 psi
N/A
K-factor 8.0
(115) 8.0
(115) 11.2 (160)
11.2 (160)
11.2 (160)
11.2 (160)
25.2 (360)
N/A
ORDINARY
DESIGN
.2/2500 (8/230)
.2/3500 (8/330)
.2/2500 (8/230)
.2/3500 (8/330)
.2/2500 (8/230)
.2/3500 (8/330)
12.0 @ 7 psi
N/A
K-factor 5.6 (80)
5.6 (80)
11.2 (160)
11.2 (160)
11.2 (160)
11.2 (160)
25.2 (360)
N/A
LIGHT
DESIGN
.1/1500 (4/140)
.1/1500 (4/140)
.2/2500 (8/230)
.2/3500 (8/330)
.2/2500 (8/230)
.2/3500 (8/330)
12.0 @ 7 psi
N/A
WET DRY WET DRY WET DRY WET DRY
HAZARD
CLASIFICATION
CEILING HEIGHT
UP TO 30 FT.
(9.1m)
CEILING HEIGHT
UP TO >30-45FT.
(9.1-13.7m)
CEILING HEIGHT
UP TO 45-60 FT.
(13.7-18.3m)
CEILING
HEIGHT UP TO
60-100 FT.
(18.3m-30.5)
(gpm/ft²)/ft² (mm/min)/m² [minimum K factor]
Table 9-3 Sprinkler Design Demand and Minimum K-Factor
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T A
L
TP #1
TP #2
BM #1
BM #2
TP #4
TP #3
BUILDING
MAINTENANCE
GARAGE
CO
EXIST 2" PMP GAS
GAS LINE MARKER
EXIST. 2" PMP GAS
EXIST. TELE
8"
6"
APPROXIM
ATE EXIST.20" W
ATER M
AIN
LOCATIO
N
B-6
A-2-3
B-3
B-1
A-2
A-2-2
B-4-1
B-2
B-5
B-2-1
B-2-2
B-4
A-3
A-2-1
D-2
A-3-1
E-1
E-2
APPROXIM
ATE LOCATIO
N EXIST. 6
" S
ANITARY FORCED M
AIN
EXIST. TOP DITCH
EXIST. TOP DITCH
CONC.
C O
N C
ASPH.
ASPH.
ASPH.
ASPH.
ASPH.
CONC.
CONC.
ASPH.
ASPH.
BUILDING ADDITION
BUILDING ADDITION
SEE SHEETS FD141A
9.018
9.017
//F A//
//F A//
FA
FA
FA
FA
FA
FA
N
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
/5
/2
:1
:5
A
M C
R e v it L o c a l\4
-1
.0
-1
-E
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
MRF
MRF
ARG
FD010
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
D E
M O
S
IT
E P
L A
N
F
IR
E A
L A
R M
KEYED NOTES
9.017 EXISTING UNDERGROUND FIRE ALARM WIRING SERVING
STORAGE BUILDING SHALL BE REMOVED. EXISTING PARTIAL
1" CONDUIT AT THIS LOCATION SHALL REMAIN TO SERVE
STORAGE BUILDING FIRE ALARM DEVICE WIRING. EXISTING
WIRING SHALL BE UTILIZED TO PULL NEW WIRING IN
EXISTING CONDUIT.
9.018 EXISTING FIRE ALARM WIRING AND CONDUIT SHALL BE
REMOVED FROM THIS LOCATION BACK TO EXISTING
REMOVED FIRE ALARM CONTROL PANEL.
10' 20' 40'
SCALE: 1" = 20'
1" = 20'-0"1
DEMO SITE PLAN - FIRE ALARM
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T
FACP
H
H H
H
H
H H
H
DS
DS
H
FS TS
H
H
J
K
L
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
MECH
ELECT
TELCOM
MATERIAL
CONTROL
/ WORK
CONTROL
TOOL
ROOM
CARPENTRY
PAVEMENT
GROUND
SHOP
WELDING
SHOP
STORAGE
MECH. /
UTILITY
SHOP
POWER
PRODUCTION
CORRIDOR
SHOP
SUPERVISORS
SHOP
SUPERVISORS
SUPPLIES
CORRIDOR
VESTIBULE
CORRIDOR
(2)
ITE
STORAGE
STAGING
/1 FD141B
/1 FD141B
RADIO ANTENNA
TOWER
//FA//
//FA//
//FA//
//FA//
//FA//
//FA//
//FA//
//FA//
//FA//
//FA//
//FA//
9.017
9.018
TO EXISTING
STORAGE BUILDING
//FA//
//FA//
TRANSMITTER
WIRING & CONDUIT.
FA
FA
FA
FA
FA
FA
FA
FA
FA
N
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
4' 8' 16'
SCALE: 1/8" = 1'-0"
/5
/2
:1
:5
A
M C
R e v it L o c a l\4
-1
.0
-1
-E
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
MRF
MRF
ARG
FD141A
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
D E
M O
F L
O O
R P
L A
N
B U
IL
D
IN
G
A
R E
A A
F
IR
E
A L
A R
M
KEYED NOTES
9.017 EXISTING UNDERGROUND FIRE ALARM WIRING SERVING
STORAGE BUILDING SHALL BE REMOVED. EXISTING PARTIAL
1" CONDUIT AT THIS LOCATION SHALL REMAIN TO SERVE
STORAGE BUILDING FIRE ALARM DEVICE WIRING. EXISTING
WIRING SHALL BE UTILIZED TO PULL NEW WIRING IN
EXISTING CONDUIT.
9.018 EXISTING FIRE ALARM WIRING AND CONDUIT SHALL BE
REMOVED FROM THIS LOCATION BACK TO EXISTING
REMOVED FIRE ALARM CONTROL PANEL.
1/8" = 1'-0"1
DEMO FLOOR PLAN - BUILDING 151 AREA A - FIRE ALARM
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T
H
H
H
H
H
DS
DS
A
C
D
E
F
G
H
J
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
WING
TRAINING
PUBLISHING
CENTER
LOBBY
TRAINING
TESTING
COMPUTER
CLASSROOM
CONFERENCE
VEST
COMM
STORAGE
BREAK
COMPUTER
CAFE
OPS
CHIEF
P & R
CHIEF
WOMEN
MEN
COMM
CC
REAL
PROP /
RA
OPEN
OFFICE
CYBER
SECURITY
NET OPS
RESTROOM
VESTIBULE
CORRIDOR
RESTROOM
VESTIBULE
/1 FD141A
/1 FD141A
N
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
4' 8' 16'
SCALE: 1/8" = 1'-0"
/5
/2
:1
:5
A
M C
R e v it L o c a l\4
-1
.0
-1
-E
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
MRF
MRF
ARG
FD141B
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
D E
M O
F L
O O
R P
L A
N
B U
IL
D
IN
G
A
R E
A B
F
IR
E
A L
A R
M
KEYED NOTES
1/8" = 1'-0"1
DEMO FLOOR PLAN - BUILDING 151 AREA B - FIRE ALARM
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T
H
H
FA TRANSMITTER PANEL
FACP
FA
ANTENNA
ETR
9.0029.002
N
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
2'-8" 5'-4" 10'-8"
SCALE: 3/16" = 1'-0"
/5
/2
:0
:4
A
M C
R e v it L o c a l\4
-1
.0
-1
-E
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
MRF
MRF
ARG
FD142
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
D E
M O
F L
O O
R P
L A
N
B U
IL
D
IN
G
S
A
B
F
IR
E
A L
A R
M
KEYED NOTES
9.002 EXISTING INCOMING UNDERGROUND FIRE ALARM WIRING SHALL BE
REMOVED. EXISTING CONDUIT SHALL REMAIN TO SERVE NEW FIRE ALARM
DEVICE WIRING. ALL EXISTING FIRE ALARM CONDUIT INTERIOR TO BUILDING
SHALL BE REMOVED.
3/16" = 1'-0"1
DEMO FLOOR PLAN - BUILDING 119B - FIRE ALARM
3/16" = 1'-0"2
DEMO FLOOR PLAN - BUILDING A - FIRE ALARM
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T
TP #1
TP #2
BM #1
BM #2
TP #4
TP #3
BUILDING
MAINTENANCE
GARAGE
CO
EXIST 2" PMP GAS
GAS LINE MARKER
EXIST. 2" PMP GAS
EXIST. TELE
8"
6"
APPROXIM
ATE EXIST.20" W
ATER M
AIN
LOCATIO
N
B-6
A-2-3
B-3
B-1
A-2
A-2-2
B-4-1
B-2
B-5
B-2-1
B-2-2
B-4
A-3
A-2-1
D-2
A-3-1
E-1
E-2
APPROXIM
ATE LOCATIO
N EXIST. 6
" S
ANITARY FORCED M
AIN
EXIST. TOP DITCH
EXIST. TOP DITCH
CONC.
C O
N C
ASPH.
ASPH.
ASPH.
ASPH.
ASPH.
CONC.
CONC.
ASPH.
ASPH.
BUILDING ADDITION
BUILDING ADDITION
SEE SHEETS F-141A
9.405
9.407
FA
FA
FA
FA
FA
FA
FA
N
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
/5
/2
:1
:5
A
M C
R e v it L o c a l\4
-1
.0
-1
-E
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
MRF
MRF
ARG
F-010
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
R E
V
IS
E D
S
IT
E P
L A
N
F
IR
E A
L A
R M
KEYED NOTES
9.405 UTILIZE EXISTING 1" UNDERGROUND CONDUIT SERVING THE
STORAGE BUILDING. INTERSECT AND EXTEND AS REQUIRED
A NEW 1" CONDUIT FROM THIS LOCATION TO NEW FIRE
ALARM MASS NOTIFICATION PANEL. EXISTING WIRING SHALL
BE REPLACED WITH NEW AND SHALL BE USED TO PULL NEW
WIRING IN EXISTING AND NEW CONDUIT.
9.407 PROVIDE 12" X 12" POLYMER CONCRETE HANDHOLE WITH
TIER 22 COVER. HANDHOLE SHALL HAVE OPEN BOTTOM
WITH GASKETED COVER. PROVIDE COVER WITH MOLDED
LETTERING 'FA'.
10' 20' 40'
SCALE: 1" = 20'
1" = 20'-0"1
REVISED SITE PLAN - FIRE ALARM
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T
J
K
L
3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
L
K
J
H
3 4 5 6 8 9 10 11 12 13 14 15 16 17
H
J
7 16 17
PA ADMIN
PERSONNEL
VESTIBULE
BCE
SERVER
ROOM
ITE
STORAGE
/ STAGING
CARPENTRY
PAVEMENT
GROUND
SHOP
WELDING
SHOP
STORAGE
MECH. /
UTILITY
SHOP
POWER
PRODUCTION
TOOL
ROOM
MATERIAL
CONTROL
/ WORK
CONTROL
SECURE
CRYPTO
SHOP
SUPERVISORS
MECH
ELECT
62 TELCOM
SUPPLIES
CORRIDOR
ENVIRONMENTAL
TRAINING
MANAGER
CORRIDOR
RESTROOM
VESTIBULE
PA NCOIC
PA
OFFICER
CORRIDOR
5.102 5.102
5.103
N
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
4' 8' 16'
SCALE: 1/8" = 1'-0"
/5
/2
:2
:1
A
M C
R e v it L o c a l\4
-1
.0
-1
-P
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
RMM
RMM
JR
F-101A
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
F
IR
S T
F L
O O
R F
IR
E
S P
R
IN
K L
E R
P L
A N
1/8" = 1'-0"1
FIRST FLOOR - AREA A
KEYED NOTES
5.102 RECONFIGURE EXISTING FIRE SPRINKLER SYSTEM TO ACCOMMODATE NEW
PARTITION WALL LAYOUT.
5.103 DISCONNECT SPRINKLER SYSTEM FROM EXISTING COMBINED WATER
SERVICE. RECONNECT TO NEW DEDICATED FIRE SPRINKLER WATER
SERVICE. REFER TO SITE UTILITY DRAWINGS FOR LOCATION OF NEW FIRE
PUMP. BASIS OF BID TO BE A 25 HP, 480V, 3 PHASE ELECTRIC FIRE PUMP
WITH JOCKEY PUMP, CONTROLLERS, TRANSFER SWITCH, ENCLOSURE, AND
ALL OTHER COMPONENTS NECESSARY FOR A COMPLETE AND OPERABLE
SYSTEM.
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T
C
D
E
F
G
H
J
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
J
H
G
F
E
D
C
A
1 2 3 4 5 6 8 9 10 11 12 13 14 15 16 17
F
H
J
16 17
G
PA ADMIN
PERSONNEL
VESTIBULE
WING
TRAINING
TRAINING
/ TESTING
COMPUTER
CLASSROOM
EM TECH
CONFERENCE
COMM
STORAGE
SIPR CAFE
COMPUTER
CAFE
OPS
CHIEF
P & R
CHIEF
COMM CC
BCE
CYBER
SECURITY
OPEN
OFFICE
REPRODUCTION
BREAK
LOBBY
VEST
WOMEN
35 MEN
MECH
ELECT
62 TELCOM
SUPPLIES
CORRIDOR
COMM
CHIEF
ENGINEERING
ENVIRONMENTAL
STAN /
EVAL
TRAINING
MANAGER
POWER
PRO 1
NET OPS
QA
CLIENT
SER. 2
KNOW
OPS
KNOW
OPS
DRAFTING
CLIENT
SER.1
CE CHIEF
DEP BCE
REAL
PROP / RA
PLANS
SHOP -
ADMIN
RESTROOM
VESTIBULE
RESTROOM
VESTIBULE
PUBLISHING
CENTER
PA NCOIC
PA
OFFICER
MULTIMEDIA
STUDIO
POWER
PRO 2
NCOIC
SHARED
ADMIN.
RADIO 1
RADIO 2
RADIO 3
RADIO 4
INFRAST.
INFRAST.
INFRAST.
INFRAST.
CLOSET
5.101
5.101
5.102
5.102
5.102
5.103
N
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
4' 8' 16'
SCALE: 1/8" = 1'-0"
/5
/2
:2
:1
A
M C
R e v it L o c a l\4
-1
.0
-1
-P
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
RMM
RMM
JR
F-101B
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
F
IR
S T
F L
O O
R F
IR
E
S P
R
IN
K L
E R
P L
A N
1/8" = 1'-0"1
FIRST FLOOR - ARAE B
KEYED NOTES
5.101 EXTEND EXISTING FIRE SPRINKLER SYSTEM TO SERVE BUILDING ADDITION.
5.102 RECONFIGURE EXISTING FIRE SPRINKLER SYSTEM TO ACCOMMODATE NEW
PARTITION WALL LAYOUT.
5.103 DISCONNECT SPRINKLER SYSTEM FROM EXISTING COMBINED WATER
SERVICE. RECONNECT TO NEW DEDICATED FIRE SPRINKLER WATER
SERVICE. REFER TO SITE UTILITY DRAWINGS FOR LOCATION OF NEW FIRE
PUMP. BASIS OF BID TO BE A 25 HP, 480V, 3 PHASE ELECTRIC FIRE PUMP
WITH JOCKEY PUMP, CONTROLLERS, TRANSFER SWITCH, ENCLOSURE, AND
ALL OTHER COMPONENTS NECESSARY FOR A COMPLETE AND OPERABLE
SYSTEM.
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T
M
M
M
M
FS TS TS
H
FMCPFSS
H
M
M
M
M M
M
M
M
M
M
M
M M
M
M M
M
M
M
MM
M
MM
F A
A P
MM CM
H
J
K
L
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
VESTIBULE
MEN
CORRIDOR
TELCOM
ELECT
MECH
ITE
STORAGE
STAGING
SERVER
ROOM
SECURE
CRYPTO
CORRIDOR
WELDING
SHOP
STORAGE
CARPENTRY
PAVEMENT
GROUND
SHOP
MECH. /
UTILITY
SHOP
CORRIDOR
POWER
PRODUCTION
SHOP
SUPERVISORS
TOOL
ROOM
MATERIAL
CONTROL
/ WORK
CONTROL
SUPPLIES
PA
OFFICER
PA
NCOIC
15 15
LOC
L O
C
/1 F-141B
/1 F-141B
RADIO ANTENNA
TOWER
9.404
9.405
TO EXISTING
STORAGE BUILDING
FA
FA
FA
FA
FA
FA
FA
FA
FA
FA
E W
S
9.406
FA
9.407 CM
DS R
T
S /I
9.408
FTP
9.410
9.410
9.410
N
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
4' 8' 16'
SCALE: 1/8" = 1'-0"
/5
/2
:1
:5
A
M C
R e v it L o c a l\4
-1
.0
-1
-E
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
MRF
MRF
ARG
F-141A
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
R E
V
IS
E D
F L
O O
R P
L A
N
B U
IL
D
IN
G
A
R E
A A
F
IR
E
A L
A R
M
KEYED NOTES
9.404 PROVIDE NEW 3/4" CONDUIT TO SERVE EXISTING FIRE ALARM
RADIO TRANSMITTER ANTENNA.
9.405 UTILIZE EXISTING 1" UNDERGROUND CONDUIT SERVING THE
STORAGE BUILDING. INTERSECT AND EXTEND AS REQUIRED
A NEW 1" CONDUIT FROM THIS LOCATION TO NEW FIRE
ALARM MASS NOTIFICATION PANEL. EXISTING WIRING SHALL
BE REPLACED WITH NEW AND SHALL BE USED TO PULL NEW
WIRING IN EXISTING AND NEW CONDUIT.
9.406 PROVIDE EARLY WARNING SMOKE DETECTION SYSTEM
CONTROLLER CAPABLE OF PROVIDING (1) ZONE OF
CONTROL, DETECTION AND DISPLAY FOR THIS ROOM.
INSTALL INDEPENDENT SAMPLING PIPE NETWORK; INSTALL
AT EXPOSED CEILING FOR MONITORING THE ABOVE FLOOR
SPACE. REFER TO SPECIFICATION SECTION 283176 FOR
ADDITIONAL INFORMATION. PROVIDE A TOTAL OF SIX (6)
MONITOR MODULES ASSOCIATED WITH CONTROLLER TO
MONITOR ALL CONTROLLER OUTPUTS. COORDINATE PIPE
LAYOUT WITH OTHER TRADES PRIOR TO INSTALLATION.
9.407 PROVIDE 12" X 12" POLYMER CONCRETE HANDHOLE WITH
TIER 22 COVER. HANDHOLE SHALL HAVE OPEN BOTTOM
WITH GASKETED COVER. PROVIDE COVER WITH MOLDED
LETTERING 'FA'.
9.408 MOUNT REMOTE TEST SWITCHES AT 60" AFF.
9.410 MANUFACTURER TO DETERMINE IF SPEAKER WILL CAUSE
BACK FEED ISSUES WITH MICROPHONE. IF ISSUES EXIST,
PROVIDE STROBE ONLY DEVICES.
1/8" = 1'-0"1
REVISED FLOOR PLAN - BUILDING 151 AREA A - FIRE ALARM
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T
M M
M M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M M
M
M
M
M
M
M
M
M
M
M
M M
M
A
C
D
E
F
G
H
J
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
WING
TRAINING
PUBLISHING
CENTER
TRAINING
TESTING
COMPUTER
CLASSROOM
MULTIMEDIA
STUDIO
PA
ADMIN /
PERSONNEL
BREAK
COMM
STORAGE
CONFERENCE
LOBBY
VEST
CLIENT
SER.1
CLIENT
SER. 2
COMPUTER
CAFE
OPS
CHIEF
P & R
CHIEF
COMM
CHIEF
RADIO 4
RADIO 3
STAN /
EVAL
RADIO 1
RADIO 2
CLOSET
CORRIDOR
WOMEN
RESTROOM
VESTIBULE
SIPR
CAFE
NET OPS
CYBER
SECURITY
PLANS
SHOP -
ADMIN
MEN
RESTROOM
VESTIBULE
OPEN
OFFICE
KNOW
OPS
KNOW
OPS
INFRAST.
INFRAST.
INFRAST.
INFRAST.
QA
COMM
CC
REAL
PROP /
RA
POWER
PRO 1
ENGINEERING
DRAFTING
SHARED
ADMIN.
NCOIC
53 EM
TECH
POWER
PRO 2
CE
CHIEF
DEP BCE
BCE
TRAINING
MANAGER
ENVIRONMENTAL
REPRODUCTION
30 30
L O
C
WP
15 15
/1 F-141A
/1 F-141A
CM
DS
CMDS
RTS/I
(2)
9.408
9.411
N
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
4' 8' 16'
SCALE: 1/8" = 1'-0"
/5
/2
:1
:5
A
M C
R e v it L o c a l\4
-1
.0
-1
-E
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
MRF
MRF
ARG
F-141B
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
R E
V
IS
E D
F L
O O
R P
L A
N
B U
IL
D
IN
G
A
R E
A B
F
IR
E
A L
A R
M
1/8" = 1'-0"1
REVISED FLOOR PLAN - BUILDING 151 AREA B - FIRE ALARM
KEYED NOTES
9.408 MOUNT REMOTE TEST SWITCHES AT 60" AFF.
9.411 MOUNTED TO MULLION. INSTALL WIRING WITHIN MULLION AS
REQUIRED.
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T
H H H
H
F A
C P
F S
S
H
HH HHH H H
BAY
BAY
STORAGE
OFFICE
MECH
RESTROOM
JANITOR
FA
ANTENNA
ETR
9.402
9.403
DS CM
RTS/I
9.408
S P
D
9.409F T
P
OPEN BAYS
STORAGE
WP
WP
9.4019.4019.4019.401
N
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
2'-8" 5'-4" 10'-8"
SCALE: 3/16" = 1'-0"
/5
/2
:0
:4
A
M C
R e v it L o c a l\4
-1
.0
-1
-E
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
MRF
MRF
ARG
F-142
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
R E
V
IS
E D
F L
O O
R P
L A
N
B U
IL
D
IN
G
S
A
B
F
IR
E
A L
A R
M
3/16" = 1'-0"1
REVISED FLOOR PLAN - BUILDING 119B - FIRE ALARM
3/16" = 1'-0"2
REVISED FLOOR PLAN - BUILDING 119A - FIRE ALARM
KEYED NOTES
9.401 UTILIZE EXISTING UNDERGROUND INCOMING FIRE ALARM CONDUIT FOR
NEW FIRE ALARM DEVICES WIRING. PROVIDE ALL NEW CONDUIT FROM THIS
EXISTING INCOMING CONDUIT TO SERVE ALL NEW DEVICES LOCATED IN
THIS BUILDING.
9.402 EXISTING FIRE ALARM ANTENNA LOCATED ON UPPER EXTERIOR FACADE
ABOVE THIS ROOM. EXISTING FIRE ALARM ANTENNA SHALL BE RE-USED
FOR TRANSMITTING SIGNALS TO BUILDINGS 131 AND 153. PROVIDE NEW
ANTENNA WIRING PER MANUFACTURER RECOMMENDATION.
9.403 PROVIDE NEW FIRE ALARM WIRING TO BUILDING 119A VIA EXISTING
UNDERGROUND FIRE ALARM CONDUIT. EXISTING WIRING SHALL BE USED
TO PULL NEW WIRING IN EXISTING CONDUIT.
9.408 MOUNT REMOTE TEST SWITCHES AT 60" AFF.
9.409 PROVIDE SPD FOR EACH 120V CIRCUIT TO CONTROL PANELS, SUBPANELS,
TRANSMITTERS, AMPLIFIER PANELS, AND BOOSTER PANELS. SPD SHALL
HAVE BOTH UL 1449 AND UL 1283 LISTING AND SHALL BE LOCATED IN AN
ADJACENT HINGED TERMINAL BOX.
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T
FIRE ALARM & MASS NOTIFICATION SYSTEM NOTES:
FIRE ALARM CONTROL UNIT AND MASS NOTIFICATION AUTONOMOUS CONTROL UNIT (FMCP) IS A COMBINED UNIT OF THE FIRE ALARM CONTROL PANEL (FACP) AND THE MNS AUTONOMOUS CONTROL UNIT (ACU). THE UNIT COULD USE
ONE OR MORE ENCLOSURES.
MASS NOTIFICATION ACU SHALL BE INTERFACED WITH THE TELEPHONE SYSTEM, SO THAT ANNOUNCEMENTS MAY BE
MADE OVER THE FA / MNS SPEAKERS VIA THE TELEPHONE SYSTEM.
ALL DETECTION AND ALARM CIRCUITS SHALL BE OF THE SUPERVISED CLASS A, STYLE D FOR INITIATING CIRCUITS AND A SUPERVISED CLASS A, STYLE Z FOR NOTIFICATION APPLIANCE CIRCUITS. SIGNALING LINE CIRCUITS (SLC) SHALL BE CLASS A, STYLE 2α.
MONITORED DEVICES INCLUDE FLOW AND TAMPER SWITCHES.
IF NOTIFICATION APPLIANCE CIRCUIT (NAC) POWER SUPPLIES OR AMPLIFIERS ARE REQUIRED, LOCATIONS SHALL BE APPROVED BY THE OWNER AND SHALL BE ACCESSIBLE TO THE FIRE DEPARTMENT. PROVIDE SMOKE DETECTOR (NOT SHOWN ON FLOOR PLANS) AT EACH NAC POWER SUPPLY/AMPLIFIER LOCATION UNLESS THE ROOM IS COVERED BY AREA SMOKE DETECTION. PROVIDE 120V POWER TO EACH LOCATION. NOTE THE SPEAKERS IN THE
SECURE AREA SHALL HAVE THEIR OWN HIGH GAIN POWER AMPLIFIER.
SEE PLANS FOR SPECIFIC CANDELA (CD) RATINGS ON NOTIFICATION APPLIANCES
ALL JUNCTION, TERMINAL, AND PULLING BOXES AND COVERS SHALL BE PAINTED RED AND SHALL BE IDENTIFIED WITH ENGRAVED LABELS BY CIRCUIT THAT IT CONTAINS. ALL CONDULETS AND SIMILAR UNITS SHALL BE PAINTED RED. ALL DETECTION AND TERMINAL DEVICES SHALL HAVE ENGRAVED PLASTIC OR METALLIC ALPHANUMERIC IDENTIFICATION, WHICH SHALL BE KEYED TO THE POSTED AND OPERATIONS AND MAINTENANCE INSTRUCTIONS.
ALL WIRING SHALL BE PER MANUFACTURER'S RECOMMENDATIONS.
WHEN THE MNS IS ANNOUNCING, AUDIBLE AND VISUAL FIRE ALARMS SHALL BE DE-ENERGIZED. CONTRACTOR SHALL
SUPPLY ALL NECESSARY EQUIPMENT TO ACCOMPLISH THIS PROCEDURE.
ALL SPEAKER AND STROBE CIRCUITS SHALL BE SUPERVISED.
STROBES SHALL BE DUAL AMBER/CLEAR TYPE WITH SEPARATE CABLING TO EACH STROBE.
SEE DRAWING FOR EXACT LOCATION OF REMOTE LOCAL OPERATION CONSOLE (LOC).
ALL SPEAKERS IN THE SECURE AREA SHALL BE TIED INTO THEIR OWN HIGH GAIN AMPLIFIER THAT IS LOCATED IN THE
SECURE AREA ROOM 126.
COORDINATE REQUIRED ALARMS MONITORED AT BASE HEAD END SYSTEM WITH OWNER PRIOR TO PROGRAMMING.
ANTENNA CABLING FMCP
COMBINED
FIRE ALARM
CONTROL PANEL
(FACP)
MNS
AUTONOMOUS
CONTROL UNIT
(ACU)
ROOM 63
120 VAC
CD
24V POWER
SLC CIRCUIT
TO OTHER DUAL AMBER/CLEAR STROBES
AND THEN BACK TO FACP/ACU
TO OTHER SPEAKERS
AND THEN BACK TO AMPLIFIER
TO OTHER EQUIPMENT
AND THEN BACK TO FACP/ACU
MONITORED
DEVICE
CONTROLLED
DEVICE
(26) #14 IN 1-1/2" C.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
H DS
RTS/I
MM CMFS TS
M M
M
AMPLIFIER
ROOM 63
CD
M
CD
M
LOC
LOC
LOC
FTP
MONACO BT-XM
MASS
NOTIFICATION
COMMUNICATOR
ROOM 63
120 VAC
STORAGE BUILDING EXISTING
INITIATING DEVICES
MM
24V POWER
SLC CIRCUIT
TO OTHER EQUIPMENT IN
EXISTING STORAGE BUILDING
AND THEN BACK TO FACP/ACU
STORAGE BUILDING
EXISTING HORN/STOBES
CM
EWS
FACP
MECH 9
NAC
CIRCUITS
CD
TO OTHER EQUIPMENT
AND THEN BACK TO FACP
TO OTHER EQUIPMENT
AND THEN BACK TO FACP
TO OTHER EQUIPMENT
AND THEN BACK TO FACP
SLC
CIRCUIT
24V POWER
FIRE ALARM NOTES:
ALL DETECTION AND ALARM CIRCUITS SHALL BE OF THE SUPERVISED CLASS B, STYLE B
FOR INITIATING CIRCUITS AND A SUPERVISED CLASS B, STYLE Y FOR NOTIFICATION
APPLIANCE CIRCUITS.
IF NOTIFICATION APPLIANCE CIRCUIT (NAC) POWER SUPPLIES OR AMPLIFIERS ARE
REQUIRED, LOCATIONS SHALL BE APPROVED BY THE OWNER AND SHALL BE
ACCESSIBLE TO THE FIRE DEPARTMENT. PROVIDE SMOKE DETECTOR (NOT SHOWN ON
FLOOR PLANS) AT EACH NAC POWER SUPPLY/AMPLIFIER LOCATION UNLESS THE ROOM
IS COVERED BY AREA SMOKE DETECTION.
SEE PLANS FOR SPECIFIC CANDELA (CD) RATINGS ON NOTIFICATION APPLIANCES
ALL JUNCTION, TERMINAL, AND PULLING BOXES AND COVERS SHALL BE PAINTED RED
AND SHALL BE IDENTIFIED WITH ENGRAVED LABELS BY CIRCUIT THAT IT CONTAINS. ALL
CONDULETS AND SIMILAR UNITS SHALL BE PAINTED RED. ALL DETECTION AND
TERMINAL DEVICES SHALL HAVE ENGRAVED PLASTIC OR METALLIC ALPHANUMERIC
IDENTIFICATION, WHICH SHALL BE KEYED TO THE POSTED AND OPERATIONS AND
MAINTENANCE INSTRUCTIONS.
ALL WIRING SHALL BE PER MANUFACTURER'S RECOMMENDATIONS.
DS
RTS/I
H
1.
2.
3.
4.
5.
24V POWER IN
EXISTING CONDUIT.
H
SLC CIRCUIT IN
EXISTING CONDUIT
TO OTHER EQUIPMENT LOCATED IN
BUILDING 119A AND THEN BACK TO
FACP
TO OTHER EQUIPMENT LOCATED
IN BUILDING 119A AND THEN BACK
TO FACP
H
NAC CIRCUITS
IN EXISTING
CONDUIT
H
120 VAC
FTP
MECH 9
120 VAC
PROVIDE (1) PAIR 16 AWG TWISTED
UNSHIELDED AUDIO CIRCUIT AND (2)
CONDUCTOR 18 AWG ZONE CIRCUIT
ANTENNA CABLING IN
CONDUIT
CM
CONTROLLED
DEVICE
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
/5
/2
:1
:5
A
M C
R e v it L o c a l\4
-1
.0
-1
-E
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
MRF
MRF
ARG
F-501
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
D E
T A
IL
S
NO SCALE1
BUILDINGS 151 FIRE ALARM RISER
NO SCALE2
BUILDINGS 119A & 119B FIRE ALARM RISER
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T
| F-001 |
| FD010 |
| FD141A |
| FD141B |
| FD142 |
| F-010 |
| F-101A |
| F-101B |
| F-141A |
| F-141B |
| F-142 |
| F-501 |
File details come from the government source that posted it. Updated .