This solicitation seeks proposals for a construction project at the Springfield Air National Guard Base in Ohio. The project consists of remodeling and additions to two civil engineering buildings, including mechanical, electrical, plumbing, communications, security, and finish work. The construction duration is 360 calendar days with an estimated value between $5-10 million.
Interested offerors must register in the System for Award Management to receive the solicitation and plans from the Federal Business Opportunities website. A pre-bid conference will be held on September 1st and proposals are due by September 24th. The North American Industry Classification for this project is 236220 with a size standard of $39.5 million average annual revenue. This solicitation is set aside for eligible 8(a) contractors. All responsible offerors are encouraged to participate.
View the file
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PITCH
PIPING SYMBOLS
PIPE TURNED TOWARD
PIPE TURNED AWAY
PIPE TURNED AWAY
UNION
FLANGES
PIPE CAP
FLUID FLOW DIRECTION
PIPE PITCH DIRECTION
NEW CONNECTION TO EXISTING
EXISTING TO REMAIN
EXISTING TO BE REMOVED
NEW TO BE INSTALLED
BALANCING VALVE
RELIEF VALVE
PRESSURE GAUGE
TEMPERATURE GAUGE
ISOLATION/SHUT-OFF/
MANUAL VALVE
STRAINER
PIPE TURNED TOWARD
CHECK VALVE
SANITARY DRAIN
VENT FOR SANITARY DRAIN
PLUMBING PIPING:
DOMESTIC HOT WATER RETURN
DOMESTIC HOT WATER
DOMESTIC COLD WATERCW
HW
HWR
SAN
V
STORM DRAINST
COMPRESSOR AIRA
OVERFLOW STORM DRAINOST
N
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
4' 8' 16'
SCALE: 1/8" = 1'-0"
/5
/2
:3
:3
A
M C
R e v it L o c a l\4
-1
.0
-1
-P
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
RMM
RMM
JR
P-001
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
N O
T E
S
S Y
M B
O L
S A
N D
A B
B R
E V
IA
T
IO
N
S
WC WATER CLOSET
NPSHA NPSH AVAILABLE W WATTS OR WIDTH
NPSH NET POSITIVE SUCTION HEAD VTR VENT THROUGH ROOF
EWC ELECTRIC WATER COOLER NOM NOMINAL VLV VALVE
ETR EXISTING TO REMAIN NO NORMALLY OPEN VFD VARIABLE FREQUENCY DRIVE
ET EXPANSION TANK NIC NOT IN CONTRACT V VOLTS OR VENT
ESEW EMERGENCY SHOWER AND EYE/FACE WASH NHC NO-HUB COUPLING UV ULTRAVIOLET
EQPT EQUIPMENT NH NO-HUB UR URINAL
ELEC ELECTRIC NG NATURAL GAS UNO UNLESS NOTED OTHERWISE
EL ELEVATION NFPA NATIONAL FIRE PROTECTION ASSOCIATION UGD UNDERGROUND
EFF EFFICIENCY NEMA NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION UFC UNIFIED FACILITIES CRITERIA
EEW EMERGENCY EYE/FACE WASH NC NORMALLY CLOSED TYP TYPICAL
E EXISTING NA NOT APPLICABLE TH THREADED
DWV DRAIN, WASTE, AND VENT MTL MATERIAL TFB TO FLOOR BELOW
DWG DRAWING MSS MANUFACTURERS STANDARDIZATION SOCIETY TFA TO FLOOR ABOVE
DN DOWN MOCP MINIMUM OVER CURRENT PROTECTION TEMP TEMPERATURE
DISCH DISCHARGE MMBH MILLION BTU PER HOUR TDS TOTAL DISSOLVED SOLIDS
DIM DIMENSION MIN MINIMUM TDH TOTAL DEVELOPED HEAD
DIA DIAMETER MFR MANUFACTURER SW SOCKET WELD
DI DUCTILE IRON MCC MOTOR CONTROL CENTER SV SOLVENT WELD
DFD DEPARTMENT OF DEFENSE MCA MINIMUM CIRCUIT AMPACITY STL STEEL
DEMO DEMOLISH MC MECHANICAL COUPLING STD STANDARD
DEG DEGREE MBH THOUSAND BTU PER HOUR SS STAINLESS STEEL
DCVA DOUBLE CHECK VALVE ASSEMBLY BPD MAX MAXIMUM SRV SAFETY RELIEF VALVE
DBA DECIBELS, BAND A MAWP MAXIMUM ALLOWABLE WORKING PRESSURE SR SERVICE SINK
CU COPPER OR CUBIC MADP MAXIMUM ALLOWABLE DIFFERENTIAL PRESSURE SQ SQUARE
CTW CLOSE TO WALL LPG LIQUIFIED PETROLEUM GAS SPEC SPECIFICATIONS
CTCLM CLOSE TO COLUMN LIN LINEAR SP STATIC PRESSURE
CTCLG CLOSE TO CEILING LCO LINE CLEANOUT SMLS SEAMLESS
CS CARBON STEEL LB POUNDS SK SINK
CRA CONCRETE REACTION ANCHOR L LENGTH OR LAVATORY SHT SHEET
COR CONTRACTING OFFICER'S REPRESENTATIVE IPC INTERNATIONAL PLUMBING CODE SHF SOCKET HEAT FUSION
COMP COMPRESSOR INWC INCHES WATER COLUMN PRESSURE SH SHOWER
CL CENTERLINE INHG INCHES MERCURY PRESSURE SDR STANDARD DIMENSION RATIO
CISPI CAST IRON SOIL PIPE INSTITUTE IN INCH SD SOLDER
CI CAST IRON IE INVERT ELEVATION SCO STACK CLEANOUT
BZ BRONZE ID INSIDE DIAMETER SCH SCHEDULE
BW BUTTWELD IBNLT INCLUDING BUT NOT LIMITED TO RPZ REDUCED PRESSURE ZONE BPD
BTW BOOTWASH IAW IN ACCORDANCE WITH RPM REVOLUTIONS PER MINUTE
BTU BRITISH THERMAL UNIT HZ HERTZ REF REFERENCE
BS BLACK (MILD) STEEL HX HEAT EXCHANGER RCP REINFORCED CONCRETE PIPE
BRZ BRONZE HP HORSEPOWER QTY QUANTITY
BRS BRASS HOA HAND-OFF-AUTO PVC POLYVINYL CHLORIDE
BR BRAZE HDB HYDROSTATIC DESIGN BASIS PSIG PSI GAGE
BPD BACKFLOW PREVENTION DEVICE HC HOSE CONNECTION PSID PSI DIFFERENTIAL
BO BID OPTION H HEIGHT PSIA PSI ABSOLUTE
BLDG BUILDING GS GALVANIZED STEEL PSI POUNDS PER SQUARE INCH
BHF BUTT HEAT FUSION GR GROOVED PREDV PRESSURE REDUCING VALVE
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS GPM GALLONS PER MINUTE PPH POUND PER HOUR ASSE AMERICAN SOCIETY OF SANITARY ENGINEERING GBS GASKETED BELL AND SPIGOT PP POLYPROPYLENE
ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS GAL GAUGE PL PLACES
ASL ABOVE SEA LEVEL GAL GALLON PH PHASE
ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS FTWC FEET WATER COLUMN PRESSURE PE POLYETHYLENE
APPROX APPROXIMATELY FT FEET PDI PLUMBING DEVELOPMENT INSTITUTE
ANG AIR NATIONAL GUARD FS FLOOR SINK PD PRESSURE DROP/DIFFERENTIAL
ALUM ALUMINIUM FPM FEET PER MINUTE P PRESSURE
AHJ AUTHORITY HAVING JURISDICTION FLOW FLOW OR FLOWRATE PCN PLANT CONTROL NETWORK
AGD ABOVEGROUND FLA FULL LOAD AMPS OFOI OWNER FURNISHED, OWNER INSTALLED
AFF ABOVE FINISHED FLOOR FD FLOOR DRAIN OFCI OWNER FURNISHED, CONTRACTOR INSTALLED
ABI ALTERNATE BID ITEM FCO FLOOR CLEANOUT OD OUTSIDE DIAMETER
A AMPS F FAHRENHEIT NPSHR NPSH REQUIRED
ABBREVIATIONS
11. GENERAL NOTES APPLY UNLESS NOTED OTHERWISE
10. NOMINAL FINISHED FLOOR ELEVATION = 100.0 FT = 707.46 FT ASL
9. SEQUENCE OF WORK AND/OR PLACE OF COMMENCEMENT OF WORK SHALL BE
APPROVED PRIOR TO WORK BEING STARTED. SCHEDULED SHUTDOWNS SHALL BE CLOSELY
COORDINATED WITH EXISTING OPERATIONS.
8. VERIFY ALL EQUIPMENT LOCATIONS AND PIPE ROUTING WITH OWNER PRIOR TO INSTALLATION.
7. TEMPORARILY PATCH ALL ROOF OPENINGS WATERTIGHT UNTIL FINAL CLOSURE CAN BE MADE.
6. ALL NEW AND EXISTING ROOFING SYSTEMS SHALL BE PROTECTED FROM DAMAGE DURING
CONSTRUCTION ACTIVITIES.
5. ACCURATE AND LEGIBLE RECORD (AS-BUILT) DRAWINGS SHALL BE MAINTAINED AT THE JOB SITE, AND BE SUBMITTED PRIOR TO FINAL PAYMENT.
4. ANY AND ALL INFORMATION SHOWN ON THESE DRAWINGS WITH RESPECT TO
EXISTING STRUCTURES, UTILITIES, AND MECHANICAL SYSTEMS, IS AS EXACT AS
COULD BE SECURED. THE INFORMATION IS NOT WARRANTED NOR GUARANTEED
ACCURATE, FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO PROCEEDING WITH WORK.
3. ELEVATION OF PIPING INDICATED ON THESE DRAWINGS ARE TO BE USED AS GUIDELINES TO
ASSIST WITH INSTALLATIONS. MINOR CHANGES TO THESE ELEVATIONS MAY BE NECESSARY TO
ELIMINATE UNFORESEEN INTERFERENCES. ANY CHANGE IN ELEVATION SHALL BE APPROVED...
2. THESE DRAWINGS ARE DESIGN DRAWINGS AND ARE DIAGRAMMATIC, THEY MAY NOT
SHOW ALL PHYSICAL ARRANGEMENTS, OFFSETS, BENDS, OR ELBOWS WHICH MAY
BE REQUIRED FOR PROPER INSTALLATION OF VARIOUS MATERIALS, EQUIPMENT, AND PIPING
SYSTEMS IN ALLOTTED SPACES. EXAMINE THESE AND OTHER AVAILABLE DRAWINGS TO DETERMINE
SPACE LIMITATIONS AND INTERFERENCES. MAKE ANY MINOR CHANGES IN LOCATIONS OF
EQUIPMENT, AND PIPING FROM THAT SHOWN ON DRAWINGS AND FOR ALL PHYSICAL DETAILS
REQUIRED FOR INSTALLATION. COST FOR ADAPTING WORK TO JOB SITE CONDITIONS SHALL NOT BE
CONSIDERED AS BASIS OF AN EXTRA COST TO CONTRACT.
1. ABBREVIATIONS INDICATED HERE AND NOT USED IN THE CONTRACT DOCUMENTS DO NOT APPLY
TO THIS PROJECT. ADDITIONAL ABBREVIATIONS MAY BE INDICATED IN THE CONTRACT...
GENERAL NOTES:
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T A
L
6.001
2" CW(E)
4" SAN(E)
4" SAN(E)
UP TO YCO(E)
4" SAN(E)
6.002
N
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
4' 8' 16'
SCALE: 1/8" = 1'-0"
/5
/2
:3
:2
A
M C
R e v it L o c a l\4
-1
.0
-1
-P
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
RMM
RMM
JR
PD099
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
U N
D G
R O
U N
D D
R A
IN
A
N D
V E
N T
D E
M O
L
IT
IO
N
P L
A N
KEYED NOTES
6.001 DEMOLISH EXISTING 1,000 GALLON OIL INTERCEPTOR. PREPARE EXISTING
DRAIN AND VENT PIPES FOR CONNECTION TO A NEW INTERCEPTOR
ACCORDING TO THE NEW WORK DRAWINGS.
6.002 DEMOLISH EXISTING TOILET ROOM PLUMBING FIXTURES AND ALL WATER
SUPPLY, WASTE AND VENT PIPE.
1/8" = 1'-0"1
UNDERGROUND DEMOLITION PLUMBING PLAN
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T
6.005
3"
/4
S A
N (E
S A
N (E
3" SAN(E)3" SAN(E)4" SAN(E)
S A
N (E
S A
N (E
VESTIBULE
SERVER
ROOM
ITE
STORAGE
/ STAGING
CARPENTRY
PAVEMENT
GROUND
SHOP
WELDING
SHOP
STORAGE
MECH. /
UTILITY
SHOP
POWER
PRODUCTION
TOOL
ROOM
MATERIAL
CONTROL
/ WORK
CONTROL
SECURE
CRYPTO
SHOP
SUPERVISORS
MECH
ELECT
62 TELCOM
SUPPLIES
CORRIDOR
CORRIDOR
RESTROOM
VESTIBULE
CORRIDOR
N
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
4' 8' 16'
SCALE: 1/8" = 1'-0"
/5
/2
:3
:4
A
M C
R e v it L o c a l\4
-1
.0
-1
-P
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
RMM
RMM
JR
PD100A
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
U N
D G
R O
U N
D D
R A
IN
A
N D
V E
N T
D E
M O
L
IT
IO
N
P L
A N
KEYED NOTES
6.005 DEMOLISH EXISTING PLUMBING FIXTURES AND ASSOCIATED PIPE.
PREPARE PIPE FOR EXTENSION ACCORDING TO THE NEW WORK
DRAWINGS.
1/8" = 1'-0"1
UNDERGOUND DRAIN AND VENT DEMOLITION PLAN - AREA A
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T
J
H
G
F
E
D
C
A
1 2 3 4 5 6 8 9 10 11 12 13 14 15 16 17
3" SAN(E)
S A
N (E
2" SAN(E)
FD(E) FD(E)
FD(E) FD(E)
S T
(E
" S
T(E
8" ST(E)
S T
(E
FD(E)
FD(E)
6.005
VESTIBULE
WING
TRAINING
TRAINING
/ TESTING
COMPUTER
CLASSROOM
EM TECH
CONFERENCE
COMM
STORAGE
SIPR CAFE
COMPUTER
CAFE
OPS
CHIEF
P & R
CHIEF
COMM CC
CYBER
SECURITY
OPEN
OFFICE
REPRODUCTION
BREAK
LOBBY
VEST
WOMEN
35 MEN
SUPPLIES
CORRIDOR
COMM
CHIEF
STAN /
EVAL
POWER
PRO 1
NET OPS
QA
CLIENT
SER. 2
KNOW
OPS
KNOW
OPS
CLIENT
SER.1
REAL
PROP / RA
PLANS
SHOP -
ADMIN
RESTROOM
VESTIBULE
RESTROOM
VESTIBULE
PUBLISHING
CENTER
POWER
PRO 2
NCOIC
RADIO 1
RADIO 2
RADIO 3
RADIO 4
INFRAST.
INFRAST.
INFRAST.
INFRAST.
CLOSET
WORKSTATIONS
N
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
4' 8' 16'
SCALE: 1/8" = 1'-0"
/5
/2
:3
:4
A
M C
R e v it L o c a l\4
-1
.0
-1
-P
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
RMM
RMM
JR
PD100B
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
U N
D G
R O
U N
D D
R A
IN
A
N D
V E
N T
D E
M O
L
IT
IO
N
P L
A N
1/8" = 1'-0"1
UNDERGOUND DRAIN AND VENT DEMOLITION PLAN - AREA B
KEYED NOTES
6.005 DEMOLISH EXISTING PLUMBING FIXTURES AND ASSOCIATED PIPE.
PREPARE PIPE FOR EXTENSION ACCORDING TO THE NEW WORK
DRAWINGS.
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T
K
J
H
3 4 5 6 8 9 10 11 12 13 14 15 16 17
6.005
HC(E)
SR(E)
SK(E)
A (E
) 3 /4
A
(E
1 1/2" A(E) 1 1/2" A(E)
/4
C
W (E
3/4" CW(E)
1" HW(E)
H W
(E
SR(E)
SK(E) SR(E)
SR(E)
A (E
/4
C
W (E
1 1/2" V(E)
1 1/4" CW(E)
1" HW(E)
1 1/2" A(E)
1 1/2" A(E)
/2
A (E
H W
(E
/4
C W
(E
1 1/2" 3/4" 1 1/2"
/2
H W
(E
FD(E)
FD(E) FD(E)
FD(E)
1" HW(E)
1 1/4" CW(E)1 1/2" V(E) 1 1/4" CW(E)
1 1/4" HW(E)
VESTIBULE
SERVER
ROOM
ITE
STORAGE
/ STAGING
CARPENTRY
PAVEMENT
GROUND
SHOP
WELDING
SHOP
STORAGE
MECH. /
UTILITY
SHOP
POWER
PRODUCTION
TOOL
ROOM
MATERIAL
CONTROL
/ WORK
CONTROL
SECURE
CRYPTO
SHOP
SUPERVISORS
MECH
ELECT
62 TELCOM
SUPPLIES
CORRIDOR
CORRIDOR
RESTROOM
VESTIBULE
CORRIDOR
N
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
4' 8' 16'
SCALE: 1/8" = 1'-0"
/5
/2
:3
:4
A
M C
R e v it L o c a l\4
-1
.0
-1
-P
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
RMM
RMM
JR
PD101A
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
F
IR
S T
F L
O O
R D
R A
IN
A
N D
V E
N T
D E
M O
L
IT
IO
N
P L
A N
KEYED NOTES
6.005 DEMOLISH EXISTING PLUMBING FIXTURES AND ASSOCIATED PIPE.
PREPARE PIPE FOR EXTENSION ACCORDING TO THE NEW WORK
DRAWINGS.
1/8" = 1'-0"1
FIRST FLOOR DRAIN AND VENT DEMOLITION PLUMBING PLAN - AREA A
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T
G
F
E
D
C
A
1 2 3 4 5 6 8 9 10 11 12 13 14 15 16 17
6.006
6.006
O S
T (E
O S
T (E
6" OST(E)
3/4" CW(E)
HC(E)
8" OST(E)
6" OST(E)
O S
T (E
3/4" CW(E)
HC(E)
HC(E)
/4
C
W (E
/4
C
W (E
O S
T (E
S T
(E
4" ST(E)
6" ST(E)
S T
(E
1" HW(E)
1 1/4" CW(E)
1 1/2" HW(E)
2" CW(E)2 1/2" V(E)
FD(E) FD(E)
6.005
6.0076.007
6.0076.0076.0076.007
VESTIBULE
WING
TRAINING
TRAINING
/ TESTING
COMPUTER
CLASSROOM
EM TECH
CONFERENCE
COMM
STORAGE
SIPR CAFE
COMPUTER
CAFE
OPS
CHIEF
P & R
CHIEF
COMM CC
CYBER
SECURITY
OPEN
OFFICE
REPRODUCTION
BREAK
LOBBY
VEST
WOMEN
35 MEN
SUPPLIES
CORRIDOR
COMM
CHIEF
STAN /
EVAL
POWER
PRO 1
NET OPS
QA
CLIENT
SER. 2
KNOW
OPS
KNOW
OPS
CLIENT
SER.1
REAL
PROP / RA
PLANS
SHOP -
ADMIN
RESTROOM
VESTIBULE
RESTROOM
VESTIBULE
PUBLISHING
CENTER
POWER
PRO 2
NCOIC
RADIO 1
RADIO 2
RADIO 3
RADIO 4
INFRAST.
INFRAST.
INFRAST.
INFRAST.
CLOSET
WORKSTATIONS
N
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
4' 8' 16'
SCALE: 1/8" = 1'-0"
/5
/2
:3
:4
A
M C
R e v it L o c a l\4
-1
.0
-1
-P
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
RMM
RMM
JR
PD101B
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
F
IR
S T
F L
O O
R D
R A
IN
A
N D
V E
N T
D E
M O
L
IT
IO
N
P L
A N
1/8" = 1'-0"1
FIRST FLOOR DRAIN AND VENT DEMOLITION PLUMBING PLAN - AREA B
KEYED NOTES
6.005 DEMOLISH EXISTING PLUMBING FIXTURES AND ASSOCIATED PIPE.
PREPARE PIPE FOR EXTENSION ACCORDING TO THE NEW WORK
DRAWINGS.
6.006 DEMOLISH EXISTING DOWNSPOUT NOZZLE. PREPARE EXISTING PIPE FOR
EXTENSION ACCORDING TO THE NEW WORK DRAWINGS.
6.007 DISCONNECT EXISTING LAVATORY AND SAVE FOR REINSTALLATION IN NEW
COUNTERTOP. PREPARE EXISTING WATER SUPPLY, DRAIN, AND VENT
ROUGH-INS FOR REINSTALLATION ACCORDING TO THE NEW WORK
DRAWINGS.
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T
6.004
6.003
6.002
HC(E) BPD(E)
AC(E)
6.0086.008
6.009
N
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
4' 8' 16'
SCALE: 1/8" = 1'-0"
/5
/2
:3
:2
A
M C
R e v it L o c a l\4
-1
.0
-1
-P
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
RMM
RMM
JR
PD102
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
F
IR
S T
F L
O O
R D
E M
O L
IT
IO
N P
L A
N
KEYED NOTES
6.002 DEMOLISH EXISTING TOILET ROOM PLUMBING FIXTURES AND ALL WATER
SUPPLY, WASTE AND VENT PIPE.
6.003 DEMOLISH EXISTING EMERGENCY SHOWER AND WATER SUPPLY PIPE.
EXISTING JANITOR SINK TO REMAIN.
6.004 DEMOLISH EXISTING ELECTRIC WATER HEATER AND WATER SUPPLY PIPE.
EXISTING WALL HYDRANT AND WATER SERVICE BACKFLOW PREVENTER TO
REMAIN. PREPARE PIPE FOR EXTENSION ACCORDING TO THE NEW WORK
DRAWINGS.
6.008 EXISTING CW AND A PIPE, FITTINGS, AND FIXTURES TO REMAIN.
6.009 DEMOLISH EXISTING DRINKING FOUNTAIN AND WATER SUPPLY, WASTE,
AND VENT PIPE.
1/8" = 1'-0"1
FIRST FLOOR DEMOLITION PLAN
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T
OPEN BAYS
STORAGE
A13
A15
A14
INT-1
4" SAN(E)
4" SAN(E)
UP TO YCO(E)
2" CW(E)
4" SAN
2" V
4" SAN
2" SAN
3" SAN(E)
4" SAN(E)
4" SAN
4" SAN
2" SAN
3" SAN
2" V
3" SAN
6.102
N
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
4' 8' 16'
SCALE: 1/8" = 1'-0"
/5
/2
:3
:2
A
M C
R e v it L o c a l\4
-1
.0
-1
-P
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
RMM
RMM
JR
P-099
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
U N
D E
R G
R O
U N
D D
R A
IN
A
N D
V E
N T
P L
A N
KEYED NOTES
6.102 MODIFY EXISTING DRAIN AND VENT PIPING AS REQUIRED TO
ACCOMMODATE THE INSTALLATION OF A NEW INT-1.
1/8" = 1'-0"1
UNDERGOUND PLAN
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T
3" SAN UP
TO FCO
4" SAN(E) 3" SAN(E) 3" SAN(E)
S A
N (E
S A
N (E
S A
N (E
S A
N (E
S A
N (E
VESTIBULE
SERVER
ROOM
ITE
STORAGE
/ STAGING
CARPENTRY
PAVEMENT
GROUND
SHOP
WELDING
SHOP
STORAGE
MECH. /
UTILITY
SHOP
POWER
PRODUCTION
TOOL
ROOM
MATERIAL
CONTROL
/ WORK
CONTROL
SECURE
CRYPTO
SHOP
SUPERVISORS
MECH
ELECT
62 TELCOM
SUPPLIES
CORRIDOR
CORRIDOR
RESTROOM
VESTIBULE
PA NCOIC
PA
OFFICER
CORRIDOR
N
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
4' 8' 16'
SCALE: 1/8" = 1'-0"
/5
/2
:3
:3
A
M C
R e v it L o c a l\4
-1
.0
-1
-P
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
RMM
RMM
JR
P-100A
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
U N
D E
R G
R O
U N
D D
R A
IN
A
N D
V E
N T
P L
A N
KEYED NOTES
1/8" = 1'-0"1
UNDERGOUND DRAIN AND VENT PLAN - AREA A
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T
S A
N (E
S A
N (E
2" SAN(E)
3" SAN(E)
S T
(E
8" ST(E)
" S
T(E
S T
(E
3" SAN
TO FCO
PA ADMIN
PERSONNEL
VESTIBULE
WING
TRAINING
TRAINING
/ TESTING
COMPUTER
CLASSROOM
EM TECH
CONFERENCE
COMM
STORAGE
SIPR CAFE
COMPUTER
CAFE
OPS
CHIEF
P & R
CHIEF
COMM CC
BCE
CYBER
SECURITY
OPEN
OFFICE
REPRODUCTION
BREAK
LOBBY
VEST
WOMEN
35 MEN
MECH
ELECT
62 TELCOM
SUPPLIES
CORRIDOR
COMM
CHIEF
ENGINEERING
ENVIRONMENTAL
STAN /
EVAL
TRAINING
MANAGER
POWER
PRO 1
NET OPS
QA
CLIENT
SER. 2
KNOW
OPS
KNOW
OPS
DRAFTING
CLIENT
SER.1
CE CHIEF
DEP BCE
REAL
PROP / RA
PLANS
SHOP -
ADMIN
RESTROOM
VESTIBULE
RESTROOM
VESTIBULE
PUBLISHING
CENTER
PA NCOIC
PA
OFFICER
MULTIMEDIA
STUDIO
POWER
PRO 2
NCOIC
SHARED
ADMIN.
RADIO 1
RADIO 2
RADIO 3
RADIO 4
INFRAST.
INFRAST.
INFRAST.
INFRAST.
CLOSET
WORKSTATIONS
N
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
4' 8' 16'
SCALE: 1/8" = 1'-0"
/5
/2
:3
:3
A
M C
R e v it L o c a l\4
-1
.0
-1
-P
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
RMM
RMM
JR
P-100B
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
U N
D E
R G
R O
U N
D D
R A
IN
A
N D
V E
N T
P L
A N
1/8" = 1'-0"1
UNDERGOUND DRAIN AND VENT PLAN - AREA B
KEYED NOTES
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T
J
H
3 4 5 6 8 9 10 11 12 13 14 15 16 17
3"FCO-1
1 1/2" V(E)
V (E
3" V(E)
FD(E) FD(E)
FD(E)FD(E)
SR(E)
SR(E)
SR(E)
SK(E)
EWC(E)
VESTIBULE
SERVER
ROOM
ITE
STORAGE
/ STAGING
CARPENTRY
PAVEMENT
GROUND
SHOP
WELDING
SHOP
STORAGE
MECH. /
UTILITY
SHOP
POWER
PRODUCTION
TOOL
ROOM
MATERIAL
CONTROL
/ WORK
CONTROL
SECURE
CRYPTO
SHOP
SUPERVISORS
MECH
ELECT
62 TELCOM
SUPPLIES
CORRIDOR
CORRIDOR
RESTROOM
VESTIBULE
PA NCOIC
PA
OFFICER
CORRIDOR
N
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
4' 8' 16'
SCALE: 1/8" = 1'-0"
/5
/2
:3
:3
A
M C
R e v it L o c a l\4
-1
.0
-1
-P
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
RMM
RMM
JR
P-101A
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
F
IR
S T
F L
O O
R D
R A
IN
A
N D
V E
N T
P L
A N
KEYED NOTES
1/8" = 1'-0"1
FIRST FLOOR DRAIN AND VENT PLAN - AREA A
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T
G
F
E
D
C
A
1 2 3 4 5 6 8 9 10 11 12 13 14 15 16 17
6"DSN-1
8"DSN-1
8" OST(E)
6" OST(E) 8" OST(E)
O S
T (E
3" ST(E)
O S
T (E
O S
T (E
S T
(E
4" ST(E)
6" ST(E)
4" ST(E)
6" OST(E)
S T
(E
6" OST(E)
O S
T (E
WC(E)
WC(E)
WC(E)
WC(E)
WC(E)
WC(E)
FD(E)
FD(E)
FD(E) FD(E)
UR(E)
UR(E)
UR(E)
2 1/2" V(E)
FD(E) FD(E)
8" OST
O S
T
6" OST
SK(E) EWC(E)
2 1/2" V(E) 1 1/2" V(E)
/2
V (E
V (E
3"FCO-1
6.1016.101
6.1016.1016.1016.101
PA ADMIN
PERSONNEL
VESTIBULE
WING
TRAINING
TRAINING
/ TESTING
COMPUTER
CLASSROOM
EM TECH
CONFERENCE
COMM
STORAGE
SIPR CAFE
COMPUTER
CAFE
OPS
CHIEF
P & R
CHIEF
COMM CC
BCE
CYBER
SECURITY
OPEN
OFFICE
REPRODUCTION
BREAK
LOBBY
VEST
WOMEN
35 MEN
MECH
ELECT
62 TELCOM
SUPPLIES
CORRIDOR
COMM
CHIEF
ENGINEERING
ENVIRONMENTAL
STAN /
EVAL
TRAINING
MANAGER
POWER
PRO 1
NET OPS
QA
CLIENT
SER. 2
KNOW
OPS
KNOW
OPS
DRAFTING
CLIENT
SER.1
CE CHIEF
DEP BCE
REAL
PROP / RA
PLANS
SHOP -
ADMIN
RESTROOM
VESTIBULE
RESTROOM
VESTIBULE
PUBLISHING
CENTER
PA NCOIC
PA
OFFICER
MULTIMEDIA
STUDIO
POWER
PRO 2
NCOIC
SHARED
ADMIN.
RADIO 1
RADIO 2
RADIO 3
RADIO 4
INFRAST.
INFRAST.
INFRAST.
INFRAST.
CLOSET
WORKSTATIONS
N
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
4' 8' 16'
SCALE: 1/8" = 1'-0"
/5
/2
:3
:3
A
M C
R e v it L o c a l\4
-1
.0
-1
-P
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
RMM
RMM
JR
P-101B
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
F
IR
S T
F L
O O
R D
R A
IN
A
N D
V E
N T
P L
A N
1/8" = 1'-0"1
FIRST FLOOR DRAIN AND VENT PLAN - AREA B
KEYED NOTES
6.101 INSTALL EXISTING LAVATORY IN NEW COUNTERTOP. MODIFY EXISTING
WATER SUPPLY, DRAIN, AND VENT ROUGH-INS AS REQUIRED.
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T
WC-1
L-1
3"FD-1
3"VTR
EWC-1
4"FD-2
SK(E)
4"FD(E)
4"FCO-1
2" V
2" V(E)
N
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
4' 8' 16'
SCALE: 1/8" = 1'-0"
/5
/2
:3
:2
A
M C
R e v it L o c a l\4
-1
.0
-1
-P
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
RMM
RMM
JR
P-102
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
F
IR
S T
F L
O O
R D
R A
IN
A
N D
V E
N T
P L
A N
KEYED NOTES
1/8" = 1'-0"1
FIRST FLOOR DRAIN AND VENT PLAN
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T
J
H
3 4 5 6 8 9 10 11 12 13 14 15 16 17
1 1/2" A(E)
A (E
/4
A
(E
1 1/2" A(E)
/4
C
W (E
A (E
3/4" A(E)
3/4" CW(E)
C W
(E
H W
(E
/2
A (E
1 1/2" A(E)
3/4" CW(E)
1" HW(E)
1 1/2" A(E)
H W
(E
/4
C W
(E
H W
(E
/2
A (E
1 1/4" CW(E)
1" HW(E)
HC(E)
1" CW(E)
VESTIBULE
SERVER
ROOM
ITE
STORAGE
/ STAGING
CARPENTRY
PAVEMENT
GROUND
SHOP
WELDING
SHOP
STORAGE
MECH. /
UTILITY
SHOP
POWER
PRODUCTION
TOOL
ROOM
MATERIAL
CONTROL
/ WORK
CONTROL
SECURE
CRYPTO
SHOP
SUPERVISORS
OPEN
OFFICE
MECH
ELECT
62 TELCOM
SUPPLIES
CORRIDOR
CORRIDOR
RESTROOM
VESTIBULE
PA NCOIC
PA
OFFICER
CORRIDOR
N
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
4' 8' 16'
SCALE: 1/8" = 1'-0"
/5
/2
:3
:3
A
M C
R e v it L o c a l\4
-1
.0
-1
-P
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
RMM
RMM
JR
P-131A
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
F
IR
S T
F L
O O
R S
U P
P L
Y P
L A
N
KEYED NOTES
1/8" = 1'-0"1
FIRST FLOOR SUPPLY PLUMBING - AREA A
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T
G
F
E
D
C
A
1 2 3 4 5 6 8 9 10 11 12 13 14 15 16 17
1 1/4" CW(E)
1" HW(E)
C W
(E
H W
(E
HC(E)
HC(E)
HC(E)
3/4" CW(E)
/4
C
W (E
3/4" CW(E)
/4
C
W (E
C W
(E
H W
(E
WC(E)
WC(E)
WC(E)
UR(E)
UR(E)
UR(E)
WC(E)
WC(E)
WC(E)
SH(E)
SH(E) SH(E)
6.1016.101
6.1016.1016.1016.101
PA ADMIN
PERSONNEL
VESTIBULE
WING
TRAINING
TRAINING
/ TESTING
COMPUTER
CLASSROOM
EM TECH
CONFERENCE
COMM
STORAGE
SIPR CAFE
COMPUTER
CAFE
OPS
CHIEF
P & R
CHIEF
COMM CC
BCE
CYBER
SECURITY
OPEN
OFFICE
REPRODUCTION
BREAK
LOBBY
VEST
WOMEN
35 MEN
SUPPLIES
CORRIDOR
COMM
CHIEF
ENGINEERING
ENVIRONMENTAL
STAN /
EVAL
TRAINING
MANAGER
POWER
PRO 1
NET OPS
QA
CLIENT
SER. 2
KNOW
OPS
KNOW
OPS
DRAFTING
CLIENT
SER.1
CE CHIEF
DEP BCE
REAL
PROP / RA
PLANS
SHOP -
ADMIN
RESTROOM
VESTIBULE
RESTROOM
VESTIBULE
PUBLISHING
CENTER
PA NCOIC
PA
OFFICER
MULTIMEDIA
STUDIO
POWER
PRO 2
NCOIC
SHARED
ADMIN.
RADIO 1
RADIO 2
RADIO 3
RADIO 4
INFRAST.
INFRAST.
INFRAST.
INFRAST.
CLOSET
WORKSTATIONS
N
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
4' 8' 16'
SCALE: 1/8" = 1'-0"
/5
/2
:3
:3
A
M C
R e v it L o c a l\4
-1
.0
-1
-P
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
RMM
RMM
JR
P-131B
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
F
IR
S T
F L
O O
R S
U P
P L
Y P
L A
N
1/8" = 1'-0"1
FIRST FLOOR SUPPLY PLUMBING - AREA B
KEYED NOTES
6.101 INSTALL EXISTING LAVATORY IN NEW COUNTERTOP. MODIFY EXISTING
WATER SUPPLY, DRAIN, AND VENT ROUGH-INS AS REQUIRED.
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T
WM-1
GWH-1
L-1
WC-1
HC(E)
AC(E)
BPD(E)
6.201
6.0086.008
1 1/2" MW
ESEW-1
1 1/2" HW
1 1/2" CW
2" CW
EWC-1
SK(E)
BPD(E)
CW(E)
6.202
N
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
4' 8' 16'
SCALE: 1/8" = 1'-0"
/5
/2
:3
:2
A
M C
R e v it L o c a l\4
-1
.0
-1
-P
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
RMM
RMM
JR
P-132
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
F
IR
S T
F L
O O
R S
U P
P L
Y P
L A
N
KEYED NOTES
6.008 EXISTING CW AND A PIPE, FITTINGS, AND FIXTURES TO REMAIN.
6.201 INSTALL NEW WM-1 IN EXISTING SPOOL PIECE GAP.
6.202 PROVIDE CONCENTRIC VENT KIT FOR GWH-1 PER MANUFACTURER
RECOMMENDATIONS.
1/8" = 1'-0"1
FIRST FLOOR SUPPLY PLUMBING
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T
0' -0 31/128"
1" MIN.
'-0
/2
28"-60"
FINISHED WALL SURFACE
VENT STACK-PIPE
MATERIAL AS SPECIFIED
MECHANICAL CONNECTOR
IF REQUIRED
CLEANOUT TEE SAME MATERIAL
AS CONNECTED PIPE
STAINLESS STEEL COVER PLATE
WITH SECURING SCREW
FINISHED FLOOR
UNDERGROUND DRAIN OR VENT
LINE PIPE MATERIAL AS SPECIFIED
WITHOUT CONCRETE TOPPINGWITH CONCRETE TOPPING
FINISHED FLOORCONCRETE TOPPING
CONCRETE
FLOOR
WATERPROOFING
MEMBRANE. EXTEND
MIN. 12" FROM DRAIN
IN ALL DIRECTIONS
EXTEND WATERPROOFING
MEMBRANE INTO SEEPAGE
PAN & SECURE WITH
CLAMPING COLLAR.
ABOVEGROUND:
PROVIDE UNDER DECK
CLAMP ON THIN SLAB
INSTALLATIONS OF 5"
OR LESS
TO TRAP
CONCRETE FLOOR
FINISHED
FLOOR
SCORIATED SECURED
POLISHED NICKEL BRONZE TOP
IN PUBLIC AREAS
CONCRETE FLOOR
GAS AND WATERTIGHT
TAPERED THREADED PLUG PIPE
CONCRETE FLOOR
IN CARPET AREAS
PROVIDE TOP WITH
CARPET MARKER
PROVIDE EXTRA HEAVY DUTY
SECURED ADJUSTABLE TOP IN
MECHANICAL RM'S, APPARATUS
BAYS, UTILITY AREAS, ETC.
1/2" TRAP PRIMER SUPPLY
DOMESTIC WATER LINE
AUTOMATIC PRESSURE
DROP ACTIVATED TRAP
PRIMER
DISTRIBUTION UNIT
FOR 5 LINES
1/2" TRAP PRIMER LINES
SLEEVE THRU SLAB
FLOOR DRAIN
FLOOR SLAB
-PROVIDE TRAP SEAL PRIMER
FOR ALL FD's & HD's.
/1
"18" MIN
'-0
/1
12"
MIN.
VENT TERMINAL
ROOFING
ROOF
CONSTRUCTION
SLEEVE ROOF
CONSTRUCTION
AS REQUIRED
INCREASER WHEN
REQUIRED
VENT STACK
FLASHING BY
ROOFING CONTRACTOR
DRAIN PIPE
UNDERGROUND VENT
-SIZE AS INDICATED
ON DRAWINGS
FINISHED FLOOR
(BY OTHERS)
SEE DRAWINGS FOR
CONTINUATION
45°
MAX
CW
CW
NC NC
H W
4" CONCRETE PAD
GAS WATER
HEATER
STORE
WATER AT
140°F.
HOT WATER
RETURN
STRAINER WITH BLOW-OFF
CIRCULATING PUMP
T & P RELIEF VALVE
EXTEND TO 6" AFF
COMBUSTION AIR PIPES,
SIZE, MATERIAL, AND
ROUTING TO EXTERIOR
IAW WATER HEATER
MANUFACTURER'S
LITERATURE.
DRAIN VALVE
FINISHED
FLOOR
PVC INDIRECT
CONDENSATE DRAIN.
SIZE IAW WATER
HEATER
MANUFACTURER'S
LITERATURE. ROUTE
TO DRAIN.
THERMOSTATIC
MIXING VALVE
EXPANSION TANK. SUPPORT
INDEPENDENTLY OF PIPING.
120°F MIXED
WATER,
(ADJUSTABLE)
1 1/16"
/3
/3
4"MIN. 4"MIN.
4"MIN.
24"MIN.
PLAN VIEW
BPD
BPD
/3
"18"MIN.
/1
"12"-84"
ELEVATION VIEW
FINISHED FLOOR
FLOOR/HUB DRAIN
PITCHED DRAIN
AIR GAP FITTING
LOW POINT
ISOLATION VALVE
HIGH POINT
OBSTRUCTIONS
VALVE HANDLE SIDE
BPD DRAIN
< 2" 2"
2" - 3" 3"
4" 4"
O N
A S
S E
-1
O N
L Y
NC
M
FLANGE
MAIN BYPASS
3/4" - 1-1/2" 3/4"
2" - 3" 1"
2"
3"
4"
4"
6"
8"
WATER SERVICE
MAIN
BYPASS. PIPE
SIZE PER TABLE
PIPE DIAMETER LONGITUDINAL SHIELD LENGTH
UP TO 3"
4"
6"
8" & LARGER
12"
15"
21"
* INCOMPRESSIBLE INSULATING BLOCK AT HANGER
WITH 24" SHIELD
THREADED ROD
(SIZE AS SPECIFIED)
CLAMP
UNISTRUT SUPPORT
INSULATION SADDLE OR
18 GAUGE SHEET METAL
INSULATION SHIELD
(PER SPECIFICATIONS)
INSULATION
ADJUSTABLR CLEVIS
TYPE HANGER
DOUBLE LOCK NUT
THREADED ROD
(SIZE AS SPECIDIED)
INSULATION
INSULATION SADDLE OR
18 GAUGE SHEET METAL
INSULATION SHIELD
(PER SPECIFICATIONS)
NUT & LOCK WASHER
N
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
4' 8' 16'
SCALE: 1/8" = 1'-0"
/5
/2
:3
:3
A
M C
R e v it L o c a l\4
-1
.0
-1
-P
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
RMM
RMM
JR
P-501
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
D E
T A
IL
S
NO SCALE1
WALL CLEANOUT (WCO)
NO SCALE2
FLOOR DRAIN - CAST IN PLACE
NO SCALE3
FLOOR CLEANOUT (FCO)
NO SCALE4
TRAP SEAL PRIMER
NO SCALE5
VENT THRU ROOF (VTR)
NO SCALE6
UNDERGROUND VENT SECTION
NO SCALE7
GAS WATER
HEATER WITH MASTER THERMO-MIXING VALVE
NO SCALE8
ASSE-1013 & ASSE-1015
NO SCALE9
WATER METER PIPING
NO SCALE10
INSULATED PIPE SUPPORTS
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T
N
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
4' 8' 16'
SCALE: 1/8" = 1'-0"
/5
/2
:3
:3
A
M C
R e v it L o c a l\4
-1
.0
-1
-P
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
RMM
RMM
JR
P-601
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
S C
H E
D U
L E
S
(4) RECEPTACLE REQUIRED (BY ELECTRICAL CONTRACTOR)
(3) EXTERNAL DISCONNECT REQUIRED (BY ELECTRICAL CONTRACTOR)
(2) DISCONNECT INCLUDED
(1) SEE GENERAL SCHEDULE NOTES
REMARKS
WATER CLOSET SEAT BEMIS, 9400SSCT OPEN FRONT. STAINLESS STEEL SELF-SUSTAINING CHECK.
WATER CLOSET FLUSHVALVE SLOAN, ROYAL 111-1.28 EXPOSED, 1.28 GPF, MANUAL. CHROME PLATED. ADA.WC- 1
WATER CLOSET BOWL KOHLER, K-4325 WALL MOUNT, 1.28 GPF, VITREOUS CHINA, TOP SPUD. ADA. PROVIDE SUPPORT.
URINAL FLUSHVALVE SLOAN, ROYAL 186-0.5 EXPOSED, 0.5 GPF, MANUAL. CHROME PLATED. ADA.
UR- 1
URINAL BOWL KOHLER, K-4960-ET WALL MOUNT, 0.5 GPF, VITREOUS CHINA, TOP SPUD. ADA. PROVIDE SUPPORT.
SERVICE SINK FAUCET CHICAGO, 897
WALL MOUNT, DUAL LEVER HANDLES, 8" CENTERS. BRACED SPOUT WITH VACUUM BREAKER.
2.2 GPM AT 60 PSI.
SR- 1
SERVICE SINK BOWL KOHLER, 6710
CORNER FLOOR-MOUNT. CAST IRON WITH ENAMEL FINISH. WITH EDGE GUARDS. 28 INCH
WIDTH X 28 INCH LENGTH X 13 INCH HEIGHT. PROVIDE MOP HANGER, HOSE ASSEMBLY, AND
WALL SHIELDS.
LAVATORY FAUCET CHICAGO, 802-317XKCP-0.5
DECK MOUNT, 4" CENTERS. DUAL WRIST BLADE HANDLES. SHAPED SPOUT. CERAMIC DISK
VALVE CARTRIDGES. 0.5 GPM AT 60 PSI. ADA. INSTALL WITH TMV-1 ON HOT CIRCUIT. INCLUDE
FIXTURE STOPS AND PROTECTIVE SHIELDING GUARDS.
L- 1
LAVATORY BOWL KOHLER, K-2005
WALL-MOUNT, VITREOUS CHINA, 21" x 18". TWO FAUCET HOLES. ADA. PROVIDE CONCEALED
ARM SUPPORT. INCLUDE DRAIN OUTLET, P-TRAP, AND PROTECTIVE SHIELDING GUARDS.
EWC- 1 WATER COOLER ELKAY, LZSTLG8WS
WALL SURFACE MOUNT, TWO-LEVEL, ADA. WITH BOTTLE FILLING STATION. COOL 7.5 GPH
WATER FROM 80 F TO 50 F AT 90 F AMBIENT. FRONT AND SIDE PUSHBARS. INCLUDE FLOW
REGULATOR. WITHOUT FILTER. STAINLESS STEEL TOP AND CABINET.
120/1 5 3
FLOW ALARM HAWS, 9001DPDT
FLOWSWITCH WITH 1 GPM SETPOINT. 90 DECIBEL AUDIBLE ALARM. 40 WATT FLASHING LIGHT.
5 AMP / 125 VAC DRY CONTACT FOR CONNECTION TO BUILDING AUTOMATION SYSTEM.
120/1 100 3
ESEW- 1
EMERGENCY SHOWER AND EYE/FACE WASH HAWS, 8200 FLOOR-MOUNT, PAINTED GALVANIZED STEEL. 20 GPM FLOW REGULATOR. INCLUDE TMV-2.
EQUIPMENT TYPE MODEL NUMBER (SEE SPECIFICATIONS) VOLTS/PHASE AMPS HP WATTS REMARKSMARK
MANUFACTURER, DESCRIPTION SUMMARY ELECTRICAL
PLUMBING FIXTURE SCHEDULE (1)
(4) RECEPTACLE REQUIRED (BY ELECTRICAL CONTRACTOR)
(3) EXTERNAL DISCONNECT REQUIRED (BY ELECTRICAL CONTRACTOR)
(2) DISCONNECT INCLUDED
(1) SEE GENERAL SCHEDULE NOTES
REMARKS
WM- 1 WATER METER BADGER METER, RECORDALL
3" COMPOUND WATER METER. PROVIDE AUXILIARY OUTPUT AND GATEWAY RECIEVER FOR
CONNECTION TO BUILDING AUTOMATION SYSTEM.
TP- 1 TRAP PRIMER PPP, PR-500SS ASSE-1018. STAINLESS STEEL. SUPPLY FROM SINK CW SUPPLY.
TMV- 3 THERMOSTATIC MIXING VALVE POWERS, LFMM433
LESS THAN 10 PSID AT 50 GPM. WITH INLET CHECK VALVES. WITH INLET AND OUTLET SHUTOFF
VALVES. WITH SURFACE-MOUNTED STAINLESS STEEL CABINET. SET AT 120 F.
TMV- 2 THERMOSTATIC MIXING VALVE POWERS, ETV200
FOR EMERGENCY FIXTURES. LESS THAN 10 PSID AT 19 GPM. WITH INLET CHECK VALVES. WITH
INLET AND OUTLET SHUTOFF VALVES. WITH SURFACE-MOUNTED STAINLESS STEEL CABINET.
SET AT 85 F.
TMV- 1 THERMOSTATIC MIXING VALVE WATTS, MMV
ASSE-1070. LESS THAN 10 PSID AT 5 GPM. WITH INLET CHECK VALVES, INLET AND OUTLET
SHUTOFF VALVES, AND UNIONS. SET AT 105 F.
O/I- 1 INTERCEPTOR, OIL GREEN TURTLE, OMC 1000
FIBERGLASS GRAVITY OIL INTERCEPTOR, 100 GALLONS TANK, 4" INLET AND OUTLET, 24"
ACCESSWAY. PROVIDE EXTENSION TO FINISHED GRADE WITH H-20 RATED MANHOLE FRAME
AND COVER.
HB- 1 HOSE BIBB WOODFORD, 24 ASSE-1011, BRONZE
WH- 1 WALL HYDRANT WOODFORD, 67-CH
ASSE-1052, BRONZE/BRASS/COPPER. FREEZEPROOF. EXPOSED KEY-OPERATED HANDLE AND
HOSE CONNECTION. INCLUDE LOOSE KEY. CHROME PLATED EXPOSED COMPONENTS.
OVERALL LENGTH AS REQUIRED FOR WALL THICKNESS.
GWH- 1 GAS WATER HEATER
HEAT TRANSFER PRODUCTS,
PH199-119
119 GALLON STAINLESS STEEL TANK. 66,000 - 199,000 BTU/HR MODULATING BURNER INPUT.
SEALED COMBUSTION WITH PVC CONCENTRIC VENTING KIT. HIGH EFFICIENCY CONDENSING.
3.5 - 14 IN WC NATURAL GAS FUEL SUPPLY. 140 F SETPOINT.
120/1 10 3
FD- 2 FLOOR DRAIN ZURN, Z508 CAST IRON, EXTRA HEAVY DUTY CAST IRON GRATE. FOR USE IN UNFINISHED SPACES.
FD- 1 FLOOR DRAIN ZURN, Z415 CAST IRON, MEDIUM DUTY NICKEL-BRONZE GRATE. FOR USE IN FINISHED SPACES.
FCO- 2 FLOOR CLEANOUT JR SMITH, Z4263
CAST IRON WITH ANCHOR FLANGE, HEAVY DUTY CAST IRON COVER. FOR USE IN UNFINISHED
SPACES.
FCO- 1 FLOOR CLEANOUT JR SMITH, Z4020 CAST IRON, MEDIUM DUTY NICKEL-BRONZE COVER. FOR USE IN FINISHED SPACES.
ET- 1 HYDROPNEUMATIC TANK AMTROL ST-12 4.4 GALLON. 40 PSIG PRECHARGE. 150 PSIG MAWP AT 200 F. NSF-61 WETTED COMPONENTS.
CS- 1 CIRCUIT SETTER TACO, ACUF-050-AC SET AT 0.5 GPM
CP- 1 CIRCULATING PUMP TACO, 007-SF5
5.0 GPM AT 9 FT HEAD, STAINLESS STEEL HOUSING, 3/4" FLANGE PORTS. CONTINUOUS
OPERATION.
120/1 0.8 3
BPD- 2 BACKFLOW PREVENTION DEVICE WILKINS, 375
REDUCED PRESSURE ZONE ASSEMBLY, ASSE 1013, 3/4", LEAD FREE BRONZE. QUARTER TURN
BALL VALVE SHUT OFF, STRAINER. INCLUDE AIR GAP FITTING.
BPD- 1 BACKFLOW PREVENTION DEVICE ETR EXISTING REDUCED PRESSURE ZONE ASSEMBLY
EQUIPMENT TYPE MODEL NUMBER (SEE SPECIFICATIONS) VOLTS/PHASE AMPS HP WATTS REMARKSMARK
MANUFACTURER, DESCRIPTION SUMMARY ELECTRICAL
PLUMBING EQUIPMENT SCHEDULE (1)
(5) UNLESS NOTED OTHERWISE, PROVIDE TRAPS ON ALL FIXTURES WITH DRAINS.
(4) CONNECT EACH FIXTURE WITH PIPE SIZES INDICATED.
(3) MATCH FIXTURE PIPE SIZE.
(2) 2" UNDERGROUND.
(1) SEE GENERAL SCHEDULE NOTES.
REMARKS:
VENT PIPE SIZE SHALL NOT DIMINISH IN DIRECTION AWAY FROM CONNECTION TO DRAIN.
DRAIN PIPE SIZE SHALL NOT DIMINISH IN UPSTREAM DIRECTION TO NEXT BRANCH.
DRAIN PIPE SIZE SHALL NOT DIMINISH IN DOWNSTREAM DIRECTION.
PIPE SIZES ARE INDICATED ON THIS SCHEDULE AND ON PLANS FROM WHERE PIPE SIZE IS...
PIPE SIZE CHANGES
SUPPLY 3/4
VTR 4
VENT 1 1/2
SANITARY DRAIN 1 1/2
SERVICE MINIMUM PIPE SIZE (IN)
MINIMUM PIPE SIZES FOR CIRCUITS
L 1/2 1/2 1 1/2 (2) 1 1/2
UR 3/4 0 2 1 1/2
WC 1 0 3 1 1/2
SK 1/2 1/2 2 1 1/2
FD/HD (3) 1 1/2
L 1/2 1/2 1 1/2 (2) 1 1/2
ESEW 1 1/4 1 1/4 0 0
EWC 1/2 0 1 1/2 (2) 1 1/2
FIXTURE DCW (IN) DHW (IN) DRAIN (IN) VENT (IN)
SUPPLY, TRAP, DRAIN, AND VENT PIPE SIZES FOR SINGLE FIXTURES (4) (5)
PIPE SIZE SCHEDULE (1)
PROVIDE WATER HAMMER ARRESTORS AT ALL AUTO/SELF
CLOSING FIXTURES. (WATERCLOSETS, URINALS, CLOTHES
WASHERS, DISHWASHERS, ETC)
NOTES:
2 1/2" 331-554 G
2" 155-330 F
1 1/2" 114-154 E
1 1/4" 60-113 D
1" 33-60 C
3/4" 12-32 B
1/2" 1-11 A
PIPE SIZE FIXTURE UNIT
CROSS REFERENCE
(PDI)
WATER HAMMER ARRESTOR SCHEDULE
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T
WC-1
L-1
SK(E)
4"FD(E)
4"FCO-1
4"FD-2
3"FD-1
EWC-1
3"VTR
4" SAN(E)
(25 DFU)
4" SAN
4" SAN
2" V
2" V
3" V 2" V(E)
2" SAN
3" SAN
3" SAN
2" V
3" V
3" V3" V
2" V 2" V
2" V
2" SAN
3" SAN(E)
TMV-2
1 1/2" MW
1 1/2" HW
1 1/2" CW
1/2" CW
EWC-1
SK(E)
3/4" HW(E)
3/4" CW(E)
1" CW(E)
1" CW(E)
3/4" HW(E)
L-1
1/2" HW
1/2" CW
1 1/2" CW
WC-1
BPD(E)
2" CW(E)
1" CW
HC(E)
BPD(E)
WM-1
2" CW(E)
1" CW(E)
2" CW(E)
/7 P-501
N
CHKD:
DRWN:
PROJ:
DESN:
A
B
C
D
E
F
2 3 4 5 6 7
Bar measures 1 inch, otherwise drawing is not to scale
C o p yr ig h t:
T e tr a T e c h
4' 8' 16'
SCALE: 1/8" = 1'-0"
/5
/2
:3
:2
A
M C
R e v it L o c a l\4
-1
.0
-1
-P
-C e n tr a l-m a tt .f ir k u s m e a d h u n t.
c o m
.r v t
4269900-170410.01
RMM
RMM
JR
P-901
S P
R
IN
G F
IE
L D
-B E
C K
L E
Y A
N G
B O
H
IO
A N
G
A D
A L C
IV
IL
E N
G
IN
E E
R
IN
G B
U
IL
D
IN
G S
W A
A R
IS
O
M E
T R
IC
S
NO SCALE1
DRAIN AND VENT PLUMBING RISER PLAN
NO SCALE2
SUPPLY PLUMBING RISER DIAGRAM
M A
R K
D A
T E
D E
S C
R
IP
T
IO
N B
Y
/1
/1
T
Y P
E B
-3 S
U B
M
IT
T
| P-001 |
| PD099 |
| PD100A |
| PD100B |
| PD101A |
| PD101B |
| PD102 |
| P-099 |
| P-100A |
| P-100B |
| P-101A |
| P-101B |
| P-102 |
| P-131A |
| P-131B |
| P-132 |
| P-501 |
| P-601 |
| P-901 |
File details come from the government source that posted it. Updated .