Specifications - Vol 2.pdf
PDF 3 MB Posted
- Attached to
- Repair and Add to Maintenance Complex - Hangar B Project Federal contract opportunity
- Solicitation number
- W50S8E22B0001
About this file
This pre-solicitation notice announces the New York Air National Guard's intent to issue an invitation for bid for repair and addition services at Hangar B at Westhampton Beach, New York. The project scope includes renovating and adding to an existing aircraft hangar, with an optional bid item for new communications wiring. The fixed-price contract duration is 365 days with performance at the 106th Rescue Wing. The procurement is set aside 100% for small businesses classified under NAICS code 236220 with a size standard of $39.5 million. The construction value is over $10 million. The pre-bid conference is scheduled for November 10, 2021 with questions due by November 5, 2021, and bids are due by November 23, 2021. Interested parties must register in the System for Award Management. The official solicitation and specifications will be available on SAM.gov, with any amendments also posted there.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Abstract of Offers Page 1.pdf | ||
| Abstract of Offers Page 3.pdf | ||
| Abstract of Offers Page 2.pdf | ||
| Attendance Sheet.pdf | ||
| RFI 50.pdf | ||
| 10 22 19.pdf | ||
| Attachment A Modified - Specifications Addendum.pdf | ||
| W50S8E22B0001 0003.pdf | ||
| RFI 48-49.pdf | ||
| WS0S8E22B0001 - Blank Vetting Form.xlsx | XLSX spreadsheet | |
| RFI 45-47.pdf | ||
| RFI 36-44.pdf | ||
| RFI 32-35.pdf | ||
| W50S8E22B0001 0002.pdf | ||
| RFI 17-31.pdf | ||
| 10 51 13 - Metal Lockers.pdf | ||
| W50S8E22B0001 0001.pdf | ||
| RFI 1-16.pdf | ||
| Attendance Sheet Page 2.pdf | ||
| PREBID Conference Slides.pdf | ||
| Attendance Sheet Page 1.pdf | ||
| PreBid Site Visit Photos_20220518.pdf | ||
| Attachment A - Specifications Addendum.pdf | ||
| Drawings.pdf | ||
| Solicitation W50S8E22B0001.pdf | ||
| Specifications - Vol 1.pdf |
Show all 26
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
New York Air National Guard
Project No’s. WKVB122004 & WKVB139002
Repair and Add To Building 358
Gabreski Air National Guard Base
Westhampton Beach, NY
Project Manual Volume 2 of 2
April 2022
100% B-3 Submittal (Issue for Bid)
Proposer’s Name and Address
ADD TO & REPAIR MAINTENANCE HANGAR
BUILDING 358
PROJECT NUMBERS: WKVB139002 & WKVB122004
106TH RESCUE WING
NEW YORK AIR NATIONAL GUARD
GABRESKI AIR NATIONAL GUARD BASE
WESTHAMPTON BEACH, NY
INDEX AND CERTIFICATION PAGE
SPECIFICATION INDEX
DOCUMENT / DIVISION
DESCRIPTION
DIVISION 01 GENERAL REQUIREMENTS
DIVISION 02 EXISTING CONDITIONS
DIVISION 03
DIVISION 04
CONCRETE
MASONRY
DIVISION 05
DIVISION 06
METALS
WOOD, PLASTICS, AND COMPOSITES
DIVISION 07 THERMAL AND MOISTURE PROTECTION
DIVISION 08 OPENINGS
DIVISION 09
DIVISION 10
DIVISION 11
DIVISION 12
DIVISION 13
FINISHES
SPECIALITIES
EQUIPMENT
FURNISHINGS
SPECIAL CONSTRUCTION
DIVISION 21 FIRE SUPPRESSION
DIVISION 22 PLUMBING
DIVISION 23 HEATING, VENTILATING AND AIR
CONDITIONING
DIVISION 26 ELECTRICAL
DIVISION 27 COMMUNICATIONS
DIVISION 28 ELECTRONIC SAFETY AND SECURITY
DIVISION 31 EARTHWORK
DIVISION 32 EXTERIOR IMPROVEMENTS
DIVISION 33
UTILITIES
CERTIFICATION(S)
WKVB139002/WKVB122004 Add To & Repair MXG Hangar, Building 358 79722 Gabreski ANGB, Westhampton Beach, NY
PROJECT TABLE OF CONTENTS
DI VI SI ON 01 - GENERAL REQUI REMENTS
01 11 00 08/15 SUMMARY OF WORK
01 14 00 11/11 WORK RESTRICTIONS
01 30 00 08/15 ADMINISTRATIVE REQUIREMENTS
01 31 23.13 20 ELECTRONIC CONSTRUCTION AND FACILITY
SUPPORT CONTRACT MANAGEMENT SYSTEM
01 32 01.00 10 02/15 PROJECT SCHEDULE
01 33 00 08/18 SUBMITTAL PROCEDURES
01 33 29 02/15 SUSTAINABILITY REPORTING
01 35 26 11/15 GOVERNMENTAL SAFETY REQUIREMENTS
01 42 00 02/19 SOURCES FOR REFERENCE PUBLICATIONS
01 45 00.00 10 02/10 QUALITY CONTROL
01 45 35 02/15 SPECIAL INSPECTIONS
01 50 00 08/09 TEMPORARY CONSTRUCTION FACILITIES AND
CONTROLS
01 57 19 11/15 TEMPORARY ENVIRONMENTAL CONTROLS
01 57 19.00 20 04/16 TEMPORARY ENVIRONMENTAL CONTROLS
01 57 20.00 10 04/06 ENVIRONMENTAL PROTECTION
01 57 23 04/08 TEMPORARY STORM WATER POLLUTION CONTROL
01 58 00 04/16 PROJECT IDENTIFICATION
01 74 19 01/07 CONSTRUCTION AND DEMOLITION WASTE
MANAGEMENT
01 75 00.00 40 05/15 STARTING AND ADJUSTING
01 78 00 08/11 CLOSEOUT SUBMITTALS
01 78 23 08/15 OPERATION AND MAINTENANCE DATA
01 91 00.00 40 11/12 COMMISSIONING
DI VI SI ON 02 - EXI STI NG CONDI TI ONS
02 41 00 05/10 DEMOLITION
DI VI SI ON 03 - CONCRETE
03 11 13.00 10 05/14 STRUCTURAL CAST-IN-PLACE CONCRETE
FORMING
03 15 00.00 10 05/14 CONCRETE ACCESSORIES
03 20 00.00 10 05/14 CONCRETE REINFORCING
03 30 00 02/19 CAST-IN-PLACE CONCRETE
03 35 00.00 10 05/14 CONCRETE FINISHING
03 39 00.00 10 05/14 CONCRETE CURING
DI VI SI ON 04 - MASONRY
04 20 00 11/15 UNIT MASONRY
DI VI SI ON 05 - METALS
05 12 00 08/18 STRUCTURAL STEEL
05 50 13 05/10 MISCELLANEOUS METAL FABRICATIONS
DI VI SI ON 06 - WOOD, PLASTI CS, AND COMPOSI TES
06 10 00 02/12 ROUGH CARPENTRY
06 41 16.00 10 08/10 PLASTIC-LAMINATE-CLAD ARCHITECTURAL
CABINETS
06 61 16 08/10 SOLID POLYMER (SOLID SURFACING)
PROJECT TABLE OF CONTENTS Page 1
FABRICATIONS
DI VI SI ON 07 - THERMAL AND MOI STURE PROTECTI ON
07 11 13 08/11 BITUMINOUS DAMPPROOFING
07 21 13 05/11 BOARD AND BLOCK INSULATION
07 21 16 11/11 MINERAL FIBER BLANKET INSULATION
07 27 36 05/17 SPRAY FOAM AIR BARRIERS
07 42 63 05/11 FABRICATED WALL PANEL ASSEMBLIES
07 53 23 05/12 ETHYLENE-PROPYLENE-DIENE-MONOMER
ROOFING
07 60 00 08/08 FLASHING AND SHEET METAL
07 61 14.00 20 05/11 STEEL STANDING SEAM ROOFING
07 72 53 03/16 SNOW GUARDS
07 84 00 05/10 FIRESTOPPING
07 92 00.00 06 06/15 JOINT SEALANTS
DI VI SI ON 08 - OPENI NGS
08 11 13 02/10 STEEL DOORS AND FRAMES
08 14 00 08/16 WOOD DOORS
08 33 23 08/15 OVERHEAD COILING DOORS
08 51 13 05/11 ALUMINUM WINDOWS
08 71 00 02/16 DOOR HARDWARE
08 81 00 08/11 GLAZING
08 91 00 05/11 METAL WALL LOUVERS
DI VI SI ON 09 - FI NI SHES
09 06 00 05/09 SCHEDULES FOR FINISHES
09 22 00 02/10 SUPPORTS FOR PLASTER AND GYPSUM BOARD
09 29 00 05/11 GYPSUM BOARD
09 30 10 11/13 CERAMIC, QUARRY, AND GLASS TILING
09 51 00 08/10 ACOUSTICAL CEILINGS
09 65 00 08/10 RESILIENT FLOORING
09 68 00 11/13 CARPETING
09 90 00 05/11 PAINTS AND COATINGS
DI VI SI ON 10 - SPECI ALTI ES
10 11 00 02/09 VISUAL DISPLAY UNITS
10 14 00.20 11/12 INTERIOR SIGNAGE
10 21 13 01/07 TOILET COMPARTMENTS
10 26 00 08/17 WALL AND DOOR PROTECTION
10 28 13 07/06 TOILET ACCESSORIES
DI VI SI ON 11 - EQUI PMENT
11 81 29 03/16 AIRCRAFT MAINTENANCE FALL PROTECTION
SYSTEMS
DI VI SI ON 12 - FURNI SHI NGS
12 21 00 08/10 WINDOW BLINDS
12 93 00 02/09 SITE FURNISHINGS
DI VI SI ON 13 - SPECI AL CONSTRUCTI ON
13 34 19 11/11 METAL BUILDING SYSTEMS
PROJECT TABLE OF CONTENTS Page 2
DI VI SI ON 21 - FI RE SUPPRESSI ON
21 13 13.00 10 05/09 WET PIPE SPRINKLER SYSTEM, FIRE
PROTECTION
DI VI SI ON 22 - PLUMBI NG
22 00 00 11/15 PLUMBING, GENERAL PURPOSE
DI VI SI ON 23 - HEATI NG, VENTI LATI NG, AND AI R CONDI TI ONI NG ( HVAC)
23 00 00 08/18 AIR SUPPLY, DISTRIBUTION, VENTILATION,
AND EXHAUST SYSTEMS
23 03 00.00 20 08/10 BASIC MECHANICAL MATERIALS AND METHODS
23 05 15 02/14 COMMON PIPING FOR HVAC
23 05 48.00 40 08/15 VIBRATION AND SEISMIC CONTROLS FOR
HVAC PIPING AND EQUIPMENT
23 05 93 11/15 TESTING, ADJUSTING, AND BALANCING FOR
HVAC
23 07 00 02/13 THERMAL INSULATION FOR MECHANICAL
SYSTEMS
23 09 00 02/19 INSTRUMENTATION AND CONTROL FOR HVAC
23 09 13 11/15 INSTRUMENTATION AND CONTROL DEVICES
FOR HVAC
23 09 23.02 02/19 BACNET DIRECT DIGITAL CONTROL FOR HVAC
AND OTHER BUILDING CONTROL SYSTEMS
23 11 25 11/08 FACILITY GAS PIPING
23 21 23 08/17 HYDRONIC PUMPS
23 23 00 10/07 REFRIGERANT PIPING
23 31 13.00 40 05/16 METAL DUCTS
23 35 19.00 20 02/10 INDUSTRIAL VENTILATION AND EXHAUST
23 52 00 04/08 HEATING BOILERS
23 54 16.00 10 04/08 HEATING SYSTEM; GAS-FIRED HEATERS
23 74 33.00 40 05/17 PACKAGED, OUTDOOR, HEATING AND COOLING
MAKEUP AIR-CONDITIONERS
23 81 00 05/18 DECENTRALIZED UNITARY HVAC EQUIPMENT
23 81 23.00 20 02/10 COMPUTER ROOM AIR CONDITIONING UNITS
23 82 46.00 40 05/17 ELECTRIC UNIT HEATERS
DI VI SI ON 26 - ELECTRI CAL
26 00 00.00 20 07/06 BASIC ELECTRICAL MATERIALS AND METHODS
26 20 00 02/14 INTERIOR DISTRIBUTION SYSTEM
26 24 13 05/15 SWITCHBOARDS
26 29 23 04/06 VARIABLE FREQUENCY DRIVE SYSTEMS UNDER
600 VOLTS
26 41 00 11/13 LIGHTNING PROTECTION SYSTEM
26 51 00 05/16 INTERIOR LIGHTING
26 56 00 05/13 EXTERIOR LIGHTING
DI VI SI ON 27 - COMMUNI CATI ONS
27 05 28.36 40 05/17 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS
27 05 29.00 10 08/11 PROTECTIVE DISTRIBUTION SYSTEM (PDS)
FOR SIPRNET COMMUNICATION SYSTEMS
27 10 00 08/11 BUILDING TELECOMMUNICATIONS CABLING
SYSTEM
PROJECT TABLE OF CONTENTS Page 3
DI VI SI ON 28 - ELECTRONI C SAFETY AND SECURI TY
28 05 26.00 40 08/13 GROUNDING AND BONDING FOR ELECTRONIC
SAFETY AND SECURITY
28 08 10 05/16 ELECTRONIC SECURITY SYSTEM ACCEPTANCE
TESTING
28 31 76 08/11 INTERIOR FIRE ALARM AND MASS
NOTIFICATION SYSTEM
DI VI SI ON 31 - EARTHWORK
31 00 00 08/08 EARTHWORK
DI VI SI ON 32 - EXTERI OR I MPROVEMENTS
32 01 16.17 08/08 COLD MILLING OF BITUMINOUS PAVEMENTS
32 11 23 08/08 AGGREGATE BASE COURSE
32 12 10 08/08 BITUMINOUS TACK AND PRIME COATS
32 12 16 08/09 HOT-MIX ASPHALT (HMA) FOR ROADS
32 16 13 04/08 CONCRETE SIDEWALKS AND CURBS AND
GUTTERS
32 92 19 10/06 SEEDING
DI VI SI ON 33 - UTI LI TI ES
33 11 00 02/11 WATER DISTRIBUTION
33 30 00 04/08 SANITARY SEWERS
33 31 23.00 10 08/18 SANITARY SEWER FORCE MAIN PIPING
33 40 00 02/10 STORM DRAINAGE UTILITIES
-- End of Project Table of Contents --
PROJECT TABLE OF CONTENTS Page 4
SECTION 10 11 00
VISUAL DISPLAY UNITS
02/09
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM B221 (2014) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes
1.2 SUMMARY
The term visual display unit when used herein includes projection screens, marker boards and tackboards; submit manufacturer's descriptive data and catalog cuts plus manufacturer's installation instructions, and cleaning and maintenance instructions. Visual display units shall be from manufacturer's standard product line. Submit certificate of compliance signed by Contractor attesting that visual display boards conform to the requirements specified.
1.3 SUSTAINABILITY REPORTING
Materials in this technical specification may contribute towards contract compliance with sustainability requirements. See Section 01 33 29.00 06 LEED CERTIFICATION for project certification local/regional materials, low-emitting materials, recycled content, USDA biobased, and LEED documentation requirements.
1.4 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for Contractor Quality Control approval. Submittals with an "S" are for inclusion in the Sustainability Notebook, in conformance to Section 01 33 29.00 06 LEED CERTIFICATION.
Submit the following in accordance with Section 01 33 00.00 06 SUBMITTAL
PROCEDURES:
SD-03 Product Data
Visual Display Unit; G
SD-04 Samples
Aluminum; G Materials; G
SD-07 Certificates
Visual Display Unit
SECTION 10 11 00 Page 1
1.5 DELIVERY, STORAGE, AND HANDLING
Deliver materials to the building site in the manufacturer's original unopened containers and store them in a clean dry area with temperature maintained above 50 degrees F. Stack materials according to manufacturer's recommendations. Visual display boards shall be allowed to acclimate to the building temperature for 24 hours prior to installation.
1.6 WARRANTY
Provide manufacturer's standard performance guarantees or warranties that extend beyond a one year period.
PART 2 PRODUCTS
2.1 MATERIALS
2.1.1 Porcelain Enamel
Provide marker board writing surface composed of porcelain enamel fused to a nominal 28 gage thick steel, laminated to a minimum 1/4 inch thick core material with a steel or foil backing sheet. Writing surface shall be capable of supporting paper by means of magnets. Marker board surface for display track system may be a powder paint dry erase surface adhered to a nominal 18 gage thick steel. Submit section showing porcelain enamel coating, steel, core material and backing.
2.1.2 Aluminum
Aluminum frame extrusions shall be alloy 6063-T5 or 6063-T6, conform to ASTM B221, and be a minimum 0.06 inches thick. Exposed aluminum shall have an anodized, satin finish. Straight, single lengths shall be used wherever possible. Joints shall be kept to a minimum. Corners shall be mitered and shall have a hairline closure. Submit sections of frame, map rail, and chalk tray, and one map hook.
2.2 MARKERBOARD
Markerboard shall have a porcelain enamel writing surface and a marker tray. Markerboard shall be a factory assembled unit complete in one piece, without joints whenever possible. When markerboard dimensions require delivery in separate sections, components shall be prefit at the factory, disassembled for delivery and jointed at the site. Frame shall be aluminum. Marker tray shall be the same material as the frame and extend the full length of the markerboard. The markerboard shall have a map rail. The map rail with a tackable insert shall extend the full length of the marker board, and shall have map hooks with clips for holding sheets of paper. Two map hooks shall be provided for each 4 foot of map rail. Dry erase markings shall be removable with a felt eraser or dry cloth without ghosting. Each unit shall come complete with an eraser and four different color compatible dry erase markers. The size shall be as shown on the drawings.
2.3 PROJECTION SCREEN
Recessed mount motorized projection screen shall have 120V motor that is lubricated for life, quick reversal type, has overload protector, integral gears, and preset accessible limit switches. Recessed mount projection
SECTION 10 11 00 Page 2 screens shall have an operable closure door and access panel. Screen shall be flame retardant, mildew resistant, and white matte with black masking borders tab tensioned. Tab tensioned screens shall have a vinyl surface that is stretchable. Bottom of screen fabric shall be weighted with metal rod. Roller shall be a rigid metal at least 3 inches in diameter mounted on sound absorbing supports. Motor will be end mounted or motor-in-roller design. Screen shall have a 3 position control switch to stop or reverse screen at any point. The switch shall be installed in a flush electrical box with cover plate, location(s) as shown on the electrical drawings. All conduit and wiring from the control switch to the projection screen shall be furnished and installed by the Contractor.
Ceiling recessed case shall be extruded aluminum. Screen shall be UL listed. The size shall be as shown in the drawings.
2.4 COLOR
Finish colors for required items shall be as specified in Section 09 06 90
COLOR SCHEDULE.
PART 3 EXECUTION
3.1 PLACEMENT SCHEDULE
Location and mounting height of visual display boards shall be as shown on the drawings.
3.2 INSTALLATION
Perform installation and assembly in accordance with manufacturer's printed instructions. Use concealed fasteners. Visual display units shall be attached with suitable devices to anchor each unit. furnish and install trim items, accessories and miscellaneous items in total, including but not limited to hardware, grounds, clips, backing materials, adhesives, brackets, and anchorages incidental to or necessary for a sound, secure, complete and finished installation. Installation shall not be initiated until completion of room painting and finishing operations.
Visual display units shall be installed in locations and at mounting heights indicated. Visual display units shall be installed level and plumb, and if applicable doors shall be aligned and hardware shall be adjusted. Damaged units shall be repaired or replaced as directed by the Contracting Officer.
3.3 CLEANING
Surfaces shall be cleaned in accordance with manufacturer's instructions.
-- End of Section --
SECTION 10 11 00 Page 3
THIS PAGE INTENTIONALLY LEFT BLANK
SECTION 10 11 00 Page 4
SECTION 10 14 00.20
INTERIOR SIGNAGE
11/12
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by basic designation only.
AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)
ANSI Z97.1 (2009; Errata 2010) Safety Glazing Materials Used in Buildings - Safety Performance Specifications and Methods of Test
ASTM INTERNATIONAL (ASTM)
ASTM D635 (2014) Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Self-Supporting Plastics in a Horizontal Position
INTERNATIONAL CODE COUNCIL (ICC)
ICC A117.1 (2009) Accessible and Usable Buildings and Facilities
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 101 (2015) Life Safety Code
U.S. GREEN BUILDING COUNCIL (USGBC)
LEED BD+C (2009; R 2010) Leadership in Energy and Environmental Design(tm) Building Design and Construction (LEED-NC)
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines
1.2 SUSTAINABILITY REPORTING
Materials in this technical specification may contribute towards contract compliance with sustainability requirements. See Section 01 33 29.00 06 LEED CERTIFICATION for project LEED BD+C local/regional materials, recycled content, low emitting materials, and LEED documentation requirements.
SECTION 10 14 00.20 Page 1
1.3 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for Contractor Quality Control approval. Submittals with an "S" are for inclusion in the Sustainability Notebook, in conformance to Section 01 33 29.00 06 LEED CERTIFICATION.
Submit the following in accordance with Section 01 33 00.00 06 SUBMITTAL
PROCEDURES:
SD-02 Shop Drawings
Detail Drawings; G
SD-03 Product Data
Installation; G
Warranty; G
SD-04 Samples
Interior Signage; G
SD-10 Operation and Maintenance Data
Approved Manufacturer's Instructions; G
Protection and Cleaning; G
SD-11 Closeout Submittals
LEED Documentation; S
1.4 EXTRA MATERIALS
Provide 5 extra frames and extra stock of sign type A. Changeable message strips for sign type A. Provide 5 paper inserts and 2 copies of the software for user produced signs and inserts after project completion and equipment necessary for removal of signage parts and pieces.
1.5 QUALITY ASSURANCE
1.5.1 Samples
Submit interior signage samples of each sign types showing typical quality, workmanship and color: Directional sign, Standard Room sign, Changeable message strip sign. The samples may be installed in the work, provided each sample is identified and location recorded.
1.5.2 Detail Drawings
Submit detail drawings showing elevations of each type of sign, dimensions, details and methods of mounting or anchoring, mounting height, shape and thickness of materials, and details of construction. Include a schedule showing the location, each sign type, and message.
1.6 DELIVERY, STORAGE, AND HANDLING
Materials shall be packaged to prevent damage and deterioration during
SECTION 10 14 00.20 Page 2 shipment, handling, storage and installation. Product shall be delivered to the job site in manufacturer's original packaging and stored in a clean, dry area in accordance with manufacturer's instructions.
1.7 WARRANTY
Warrant the interior signage for a period of 2 years against defective workmanship and material. Warranties shall be signed by the authorized representative of the manufacturer. Submit warranty accompanied by the document authenticating the signer as an authorized representative of the guarantor. Guarantee that the signage products and the installation are free from any defects in material and workmanship from the date of delivery.
PART 2 PRODUCTS
2.1 STANDARD PRODUCTS
Signs, plaques, directories, and dimensional letters shall be the standard product of a manufacturer regularly engaged in the manufacture of such products that essentially duplicate signs that have been in satisfactory use at least 2 years prior to bid opening. Obtain signage from a single manufacturer with edges and corners of finished letterforms and graphics true and clean.
2.2 ROOM IDENTIFICATION/DIRECTIONAL SIGNAGE SYSTEM
2.2.1 Standard Room Signs
Signs shall consist of acrylic plastic 0.080 inch thickness minimum conforming to ANSI Z97.1 and shall conform to the following:
a. Units shall be frameless. Corners of signs shall be rounded to 3/8 inch radius.
2.2.2 Changeable Message Strip Signs
Changeable message strip signs shall be of same construction as standard room signs to include a clear sleeve that will accept a paper or plastic insert identifying changeable text. The insert shall be prepared typeset message mounted on paper card stock. Provide paper and software for creating text and symbols for computers identified by owner for Owner production of paper inserts after project completion. Furnish one device to assist in removing face sheet. Sliding inserts or slide knobs that slide horizontally exposing different graphic information shall be provided as identified in the signage placement schedule and drawings.
2.2.3 Type of Mounting for Signs
Provide extruded aluminum brackets for hanging, projecting, and double-sided signs. Mounting for framed, hanging, and projecting signs shall be by mechanical fasteners. Surface-mounted signs shall be mounted with 1/16 inch thick closed cell vinyl foam with adhesive backing.
Adhesive shall be transparent, long aging, high tech formulation on two sides of the vinyl foam.
2.2.4 Graphics
Signage graphics for modular signs shall conform to the following:
SECTION 10 14 00.20 Page 3
2.2.4.1 Subsurface Copy
Copy is transferred to the back face of clear acrylic sheeting forming the panel face to produce precisely formed opaque image. This method bonds all sign elements (color, graphics, lettering, Braille and substrate) into a single unit.
2.2.4.2 First Surface Copy Direct Print or Silkscreened (Non-Tactile)
Message may be applied to panel using the silkscreen process.
Silkscreened images shall be executed with photo screens prepared from original art. Handcut screens will not be accepted. Original art is defined as artwork that is a first generation reproduction of the specified art. Edges and corners shall be clean.
2.2.4.3 Surface-Applied Photopolymer
Integral graphics and Braille achieved by photomechanical stratification processes. Photopolymer used for ADA compliant graphics shall be of the type that has a minimum durometer reading of 90. Tactile graphics shall be raised 1/32 inch from the first surface of plaque by photomechanical stratification process.
2.2.4.4 Engraved Copy
Machine engrave letters, numbers, symbols, and other graphics into panel sign on face to produce precisely formed copy and sharp images, incised to uniform depth. Melamine plastic engraving stock used for ADA compliant graphic shall be three-ply lamination contrasting color core meeting
ASTM D635.
2.2.5 Character Proportions and Heights
Letters and numbers on signs conform to 36 CFR 1191 .
2.2.6 Tactile Letters, Symbols and Braille
Raised letters and numbers on signs shall conform to 36 CFR 1191 .
2.3 STAIR SIGNAGE
Provide signs on stairs within the enclosure at each floor landing conforming to NFPA 101 . Indicate the floor level, the terminus of the top and bottom of the stair enclosure, and the identification of the stair enclosure. Also, state the floor level of, and the direction to, exit discharge. Locate the signage inside the enclosure in a position that is visible when the door is in the open or closed position and install in conformance with 36 CFR 1191 . The floor level designation shall also be tactile in accordance with ICC A117.1 .
2.4 FABRICATION AND MANUFACTURE
2.4.1 Factory Workmanship
Holes for bolts and screws shall be drilled or punched. Drilling and punching shall produce clean, true lines and surfaces. Exposed surfaces of work shall have a smooth finish and exposed riveting shall be flush.
Fastenings shall be concealed where practicable.
SECTION 10 14 00.20 Page 4
2.4.2 Dissimilar Materials
Where dissimilar metals are in contact, the surfaces will be protected to prevent galvanic or corrosive action.
2.5 COLOR, FINISH, AND CONTRAST
Color shall be in accordance with Section 09 06 90 COLOR SCHEDULE. Finish of all signs shall be eggshell, matte, or other non-glare finish as required in handicapped-accessible buildings.
2.6 TYPEFACE
ADA-ABA compliant font for Room Signs: Per drawings.
PART 3 EXECUTION
3.1 INSTALLATION
Signs shall be installed plumb and true and in accordance with approved manufacturer's instructions at locations shown on the detail drawings.
Submit six copies of operating instructions outlining the step-by-step procedures required for system operation. The instructions shall include simplified diagrams for the system as installed, the manufacturer's name, model number, service manual, parts list, and brief description of all equipment and their basic operating features. Each set shall be permanently bound and shall have a hard cover. The following identification shall be inscribed on the covers: The words "OPERATING AND MAINTENANCE INSTRUCTIONS," name and location of the facility, name of the Contractor, and contract number. Mounting height and mounting location shall conform to 36 CFR 1191 . Required blocking shall be installed.
Signs on doors or other surfaces shall not be installed until finishes on such surfaces have been installed. Signs installed on glass surfaces shall be installed with matching blank back-up plates in accordance with manufacturer's instructions.
3.1.1 Anchorage
Anchorage shall be in accordance with approved manufacturer's instructions. Anchorage not otherwise specified or shown shall include slotted inserts, expansion shields, and powder-driven fasteners when approved for concrete; toggle bolts and through bolts for masonry; machine carriage bolts for steel; lag bolts and screws for wood. Exposed anchor and fastener materials shall be compatible with metal to which applied and shall have matching color and finish.
a. Signs mounted to painted gypsum board surfaces shall be removable for painting maintenance.
b. Mount signs mounted to lay-in ceiling grids with clip connections to ceiling tees.
c. Install signs mounted on metal surfaces with magnetic tape.
d. Install signs mounted on fabric surfaces with hook and loop tape or pin mount.
e. Install signs mounted on glass with double sided foam tape and backer
SECTION 10 14 00.20 Page 5 panel to hide exposed tape.
3.1.2 Protection and Cleaning
Protect the work against damage during construction. Hardware and electrical equipment shall be adjusted for proper operation. Glass, frames, and other sign surfaces shall be cleaned at completion of sign installation in accordance with the manufacturer's approved instructions and the requirements of Section 01 78 23 OPERATION AND MAINTENANCE DATA, Package 1. Submit six copies of maintenance instructions listing routine procedures, repairs, and guides.
SECTION 10 14 00.20 Page 6
SECTION 10 21 13
TOILET COMPARTMENTS
01/07
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ALUMINUM ASSOCIATION (AA)
AA DAF45 (2003; Reaffirmed 2009) Designation System for Aluminum Finishes
ASTM INTERNATIONAL (ASTM)
ASTM A123/A123M (2013) Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products
ASTM A167 (2011) Standard Specification for Stainless and Heat-Resisting Chromium-Nickel Steel Plate, Sheet, and Strip
ASTM A336/A336M (2010a) Standard Specification for Alloy Steel Forgings for Pressure and High-Temperature Parts
ASTM A385/A385M (2011) Standard Practice for Providing High-Quality Zinc Coatings (Hot-Dip)
ASTM B221 (2014) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes
ASTM B36/B36M (2013) Standard Specification for Brass Plate, Sheet, Strip, and Rolled Bar
ASTM B456 (2011; E 2011) Standard Specification for Electrodeposited Coatings of Copper Plus Nickel Plus Chromium and Nickel Plus Chromium
ASTM B86 (2013) Standard Specification for Zinc and Zinc-Aluminum (ZA) Alloy Foundry and Die Castings
ASTM D7611/D7611M (2013; E 2014) Standard Practice for Coding Plastic Manufactured Articles for Resin Identification
SECTION 10 21 13 Page 1
INTERNATIONAL CODE COUNCIL (ICC)
ICC A117.1 (2009) Accessible and Usable Buildings and Facilities
U.S. GENERAL SERVICES ADMINISTRATION (GSA)
CID A-A-60003 (Basic) Partitions, Toilet, Complete
U.S. GREEN BUILDING COUNCIL (USGBC)
LEED BD+C (2009; R 2010) Leadership in Energy and Environmental Design(tm) Building Design and Construction (LEED-NC)
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines
1.2 SUSTAINABILITY REPORTING
Materials in this technical specification may contribute towards contract compliance with sustainability requirements.
1.2.1 LEED REQUIREMENTS
See Section 01 33 29.00 06 LEED CERTIFICATION for project LEED BD+C local/regional materials, low-emitting materials, recycled content, and LEED documentation requirements.
1.2.2 EPA Comprehensive Procurement Guidelines
See Section 01 33 29.00 06 LEED CERTIFICATION for requirements associated with EPA designated products.
1.3 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for Contractor Quality Control approval. Submittals with an "S" are for inclusion in the Sustainability Notebook, in conformance to Section 01 33 29.00 06 LEED CERTIFICATION.
Submit the following in accordance with Section 01 33 00.00 06 SUBMITTAL
PROCEDURES:
SD-02 Shop Drawings
Fabrication Drawings
SD-03 Product Data
Cleaning and Maintenance Instructions
Colors and Finishes
Anchoring Devices and Fasteners
SECTION 10 21 13 Page 2
Hardware and Fittings
Brackets
Door Hardware
Local/Regional Materials Documentation; S
Environmental Data
Toilet Enclosures; S
Urinal Screens; S
Pilaster Shoes; S
SD-04 Samples
Colors and Finishes
Hardware and Fittings
Anchoring Devices and Fasteners
SD-07 Certificates
Warranty
SD-10 Operation and Maintenance Data
Plastic Identification
SD-11 Closeout Submittals
LEED Documentation; S
Local/Regional Materials Documentation; S
Toilet Enclosures; S
Urinal Screens; S
Pilaster Shoes; S
1.4 REGULATORY REQUIREMENTS
Conform to ICC A117.1 code for access for the handicapped operation of toilet compartment door and hardware.
1.5 DELIVERY, STORAGE, AND HANDLING
Deliver materials in the manufacturer's original unopened packages with the brand, item identification, and project reference clearly marked.
Store components in a dry location that is adequately ventilated; free from dust, water, other contaminants, and damage during delivery, storage, and construction.
SECTION 10 21 13 Page 3
1.6 WARRANTY
Provide certification or warranties that metal toilet partitions will be free of defects in materials, fabrication, finish, and installation and will remain so for a period of not less than 25 years after completion.
PART 2 PRODUCTS
2.1 SYSTEM REQUIREMENTS
Provide a complete and usable toilet partition system, including toilet enclosures, urinal screens, system of panels, hardware, and support components. Comply with EPA requirements in accordance with Section 01 33 29.00 06 LEED CERTIFICATION and Affirmative Procurement guidelines.
Furnish the partition system from a single manufacturer with a standard product as shown in the most recent catalog data. Submit Fabrication Drawings for HPDE toilet partitions and urinal screens consisting of fabrication and assembly details to be performed in the factory. Submit manufacturer's Cleaning and Maintenance Instructions with Fabrication Drawings for review.
2.1.1 Sustainable Design Requirements
2.1.1.1 Local/Regional Materials Documentation
Submit documentation indicating distance between manufacturing facility and the project site. Indicate distance of raw material origin from the project site. Indicate relative dollar value of local/regional materials to total dollar value of products included in project.
2.1.1.2 Environmental Data
Submit documentation indicating percentage of post-industrial and post-consumer recycled content per unit of product. Indicate relative dollar value of recycled content products to total dollar value of products included in project.
2.1.2 Plastic Identification
Verify that plastic products to be incorporated into the project are labeled in accordance with ASTM D7611/D7611M . Where products are not labeled, provide product data indicating polymeric information in the Operation and Maintenance Manual.
Type 1 Polyethylene Terephthalate (PET, PETE)
Type 2 High Density Polyethylene (HDPE)
Type 3 Vinyl (Polyvinyl Chloride or PVC)
Type 4 Low Density Polyethylene (LDPE)
Type 5 Polypropylene (PP)
Type 6 Polystyrene (PS)
SECTION 10 21 13 Page 4
Type 1 Polyethylene Terephthalate (PET, PETE)
Type 7 Other. Use of this code indicates that the package in question is made with a resin other than the six listed above, or is made of more than one resin listed above, and used in a multi-layer combination.
2.2 MATERIALS
2.2.1 High Density Polyethylene (Type 2)
Provide high density, polyethylene in accordance with ASTM D7611/D7611M .
2.2.2 Anchoring Devices and Fasteners
Provide steel anchoring devices and fasteners hot-dipped galvanized after fabrication, in conformance with ASTM A385/A385M and ASTM A123/A123M .
Conceal all galvanized anchoring devices.
2.2.3 Brackets
Wall brackets shall be two-ear panel brackets, T-style, 1-inch stock.
Provide stirrup style panel-to-pilaster brackets.
2.2.4 Hardware and Fittings
2.2.4.1 General Requirements
Conform hardware for the toilet partition system to CID A-A-60003 for the specified type and style of partitions. Provide hardware finish highly resistant to alkalis, urine, and other common toilet room acids. Comply latching devices and hinges for handicap compartments with 36 CFR 1191 ;
provide chrome-plated steel or stainless steel devices and hinges with door latches that operate without either tight grasping or twisting of the wrist of the operator. Submit three samples of each item, including anchoring devices and fasteners. Approved hardware samples may be installed in the work if properly identified.
Material Conformance Standard
Cold-rolled sheet steel ASTM A336/A336M , commercial quality
Zinc-base alloy ASTM B86, Alloy AC41-A
Brass ASTM B36/B36M, Alloy C26800
Aluminum ASTM B221
Corrosion-resistant steel ASTM A167, Type 304
2.2.4.2 Finishes
a. Chrome plating shall conform to ASTM B456.
b. Aluminum shall have a clear anodic coating conforming to AA DAF45.
SECTION 10 21 13 Page 5
c. Corrosion-resistant steel shall have a No. 4 finish.
d. Exposed fasteners shall match the hardware and fittings.
2.2.5 Door Hardware
2.2.5.1 Hinges
Hinges shall be adjustable to hold in-swinging doors open at any angle up to 90 degrees and outswinging doors to 10 degrees. Provide self-lubricating hinges with the indicated swing. Hinges shall be the surface-mounted type, have the following type of return movement:
a. Gravity return movement.
2.2.5.2 Latch and Pull
Latch and pull shall be a combination rubber-faced door strike and keeper equipped with emergency access.
2.2.5.3 Coat Hooks
Coat hooks shall be combination units with hooks and rubber tipped pins.
2.3 PARTITION PANELS AND DOORS
Fabricate partition panels and doors not less than 1 inch thick.
2.3.1 Toilet Enclosures
Conform toilet enclosures to CID A-A-60003 , Type I, Style C floor supported and overhead braced. Furnish width, length, and height of toilet enclosures as shown. Provide minimum thickness of 1 inch. Finish surface of panels shall be solid polyethylene, Finish orange peel; water resistant; graffiti resistant; non-absorbent. See Section 01 33 29.00 06 LEED CERTIFICATION for cumulative total recycled content requirements.
Reinforce panels indicated to receive toilet paper holders or grab bars for mounting of the items required. Provide mounting reinforcement for grab bars to withstand a bending stress, shear stress, shear force, and a tensile force induced by 250 lbf. Grab bars shall not rotate within their fittings.
2.3.2 Urinal Screens
Conform urinal screens to CID A-A-60003 , Type III, Style D, wall hung.
Provide finish for surface of screens as solid polyethylene, Finish orange peel; water resistant; graffiti resistant; non-absorbent. See Section 01 33 29.00 06 LEED CERTIFICATION for cumulative total recycled content requirements. This item may contain post-consumer or post-industrial recycled content. Furnish width and height of urinal screens as shown.
Provide thickness of 1 inch. Secure wall hung urinal screens with 42 inch long, continuous flanges. Fabricate screens from the same types of panels and pilasters as the toilet partitions. Use corrosion-resistant steel fittings and fasteners.
2.4 PILASTER SHOES
Provide shoes at pilasters to conceal floor-mounted anchorage. Pilaster shoes shall be stainless steel. See Section 01 33 29.00 06 LEED
SECTION 10 21 13 Page 6
CERTIFICATION for cumulative total recycled content requirements. Height shall be 3 inches.
2.5 HARDWARE
Hardware for the toilet partition system shall conform to CID A-A-60003 for the specified type and style of partitions. Hardware shall be pre-drilled by manufacturer. Hardware finish shall be highly resistant to alkalis, urine, and other common toilet room acids. Hardware shall include: Chrome plated non-ferrous cast pivot hinges, gravity type, adjustable for door close positioning; nylon bearings; black anodized aluminum door latch; door strike and keeper with rubber bumper; and cast alloy chrome plated coat hook and bumper. Latching devices and hinges for handicap compartments shall comply with 36 CFR 1191 and shall be chrome-plated steel or stainless steel door latches that operate without either tight grasping or twisting of the wrist of the operator. Screws and bolts shall be stainless steel, tamper proof type. Wall mounting brackets shall be continuous, full height, aluminum or stainless steel, in accordance with toilet compartment manufacturer's instructions.
Floor-mounted anchorage shall consist of corrosion-resistant anchoring assemblies with threaded rods, lock washers, and leveling adjustment nuts at pilasters for structural connection to floor.
2.6 COLORS AND FINISHES
2.6.1 Colors
Provide color and texture in accordance with Section 09 06 90 COLOR SCHEDULE for toilet partition system components. Submit three samples showing a finished edge on two adjacent sides and core construction, each not less than 12-inch square.
2.6.2 Finishes No. 4 and No. 5
Provide solid plastic fabricated of polymer resins (polyethylene) formed under high pressure rendering a single component section not less than 1 inch thick. Colors shall extend throughout the panel thickness. Provide exposed finish surfaces: Smooth, waterproof, non-absorbent, and resistant to staining and marking with pens, pencils, or other writing devices.
Solid plastic partitions shall not show any sign of deterioration when immersed in the following chemicals and maintained at a temperature of 80 degrees F for a minimum of 30 days:
Acetic Acid (80 percent) Hydrochloric Acid (40 percent)
Acetone Hydrogen Peroxide (30 percent)
Ammonia (liquid) Isopropyl Alcohol
Ammonia Phosphate Lactic Acid (25 percent)
Bleach (12 percent) Lime Sulfur
Borax Nicotine
SECTION 10 21 13 Page 7
Brine Potassium Bromide
Caustic Soda Soaps
Chlorine Water Sodium Bicarbonate
Citric Acid Trisodium Phosphate
Copper Chloride Urea; Urine
Core Oils Vinegar
PART 3 EXECUTION
3.1 PREPARATION
Take field measurements prior to the preparation of drawing and fabrication to ensure proper fits. Verify that field measurements, surfaces, substrates and conditions are as required, and ready to receive work. Verify correct spacing of plumbing fixtures. Verify correct location of built in framing, anchorage, and bracing. Report in writing to Contracting Officer prevailing conditions that will adversely affect satisfactory execution of the work of this section. Do not proceed with work until unsatisfactory conditions have been corrected.
3.2 INSTALLATION
Install partitions rigid, straight, plumb, and level, with the panels centered between the fixtures. Provide a panel clearance of not more than 1/2 inch and secure the panels to walls and pilasters with not less than two wall brackets attached near the top and bottom of the panel. Locate wall brackets so that holes for wall bolts occur in masonry or tile joints. Secure Panels to pilasters with brackets matching the wall brackets. Provide for adjustment due to minor floor variations. Locate head rail joints at pilaster center lines. Install adjacent components for consistency of line and plane. Equip each door with hinges, one door latch, and one coat hook and bumper. Align hardware to uniform clearance at vertical edges of doors.
a. Secure panels to hollow plastered walls with toggle bolts using not less than 1/4-20 screws of the length required for the wall thickness. Toggle bolts shall have a load-carrying strength of not less than 600 pounds per anchor.
b. Secure panels to ceramic tile on hollow plastered walls or hollow concrete-masonry walls with toggle bolts using not less than 1/4-20 screws of the length required for the wall thickness. Toggle bolts shall have a load-carrying strength of not less than 600 pounds per anchor.
3.3 OVERHEAD-BRACED PARTITIONS
Secure pilasters to the floor with the anchorage device specified. Make all leveling devices readily accessible for leveling, plumbing, and tightening the installation. Secure overhead brace to the pilaster face with not less than two fasteners per face. Expansion shields shall have a minimum 2-inch penetration into the concrete slab. Make tops of doors
SECTION 10 21 13 Page 8 parallel with the overhead brace when doors are in a closed position.
3.4 FINAL ADJUSTMENT
After completion of the installation, make final adjustments to the pilaster-leveling devices, door hardware, and other working parts of the partition assembly. Doors shall have a uniform vertical edge clearance of approximately 3/16 inch and shall rest open at approximately 30 degrees when unlatched.
3.5 CLEANING
Baked enamel finish shall be touched up with the same color of paint that was used for the finish. Clean all surfaces of the work, and adjacent surfaces soiled as a result of the work, in an approved manner compliant with the manufacturer's recommended cleaning and protection from damage procedures until accepted. Remove all equipment, tools, surplus materials, and work debris from the site.
SECTION 10 21 13 Page 9
SECTION 10 21 13 Page 10
SECTION 10 26 00
WALL AND DOOR PROTECTION
08/17
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ALUMINUM ASSOCIATION (AA)
AA DAF45 (2003; Reaffirmed 2009) Designation System for Aluminum Finishes
ASTM INTERNATIONAL (ASTM)
ASTM A240/A240M (2018) Standard Specification for Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels and for General Applications
ASTM B221 (2014) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes
ASTM D256 (2010; R 2018) Standard Test Methods for Determining the Izod Pendulum Impact Resistance of Plastics
ASTM D543 (2014) Standard Practices for Evaluating the Resistance of Plastics to Chemical Reagents
ASTM D635 (2018) Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position
ASTM E84 (2018a) Standard Test Method for Surface Burning Characteristics of Building Materials
ASTM G21 (2015) Standard Practice for Determining Resistance of Synthetic Polymeric Materials to Fungi
CALIFORNIA DEPARTMENT OF PUBLIC HEALTH (CDPH)
CDPH SECTION 01350 (2010; Version 1.1) Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources using Environmental Chambers
SECTION 10 26 00 Page 1
GREEN SEAL (GS)
GS-36 (2013) Adhesives for Commercial Use
NATIONAL ASSOCIATION OF ARCHITECTURAL METAL MANUFACTURERS (NAAMM)
NAAMM AMP 500 (2006) Metal Finishes Manual
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 80 (2016; TIA 16-1) Standard for Fire Doors and Other Opening Protectives
SCIENTIFIC CERTIFICATION SYSTEMS (SCS)
SCS SCS Global Services (SCS) Indoor Advantage
SOCIETY OF AUTOMOTIVE ENGINEERS INTERNATIONAL (SAE)
SAE J1545 (2005; R 2014) Instrumental Color Difference Measurement for Exterior Finishes, Textiles and Colored Trim
SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD)
SCAQMD Rule 1168 (2017) Adhesive and Sealant Applications
UNDERWRITERS LABORATORIES (UL)
UL 2818 (2013) GREENGUARD Certification Program For Chemical Emissions For Building Materials, Finishes And Furnishings
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for [Contractor Quality Control approval.] [information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government.] Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section
01 33 00 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Corner Guards; G [, [_____]]
Wall Guards (Bumper Guards); G [, [_____]]
Door Protectors; G [, [_____]]
Wall Covering/Panels; G [, [_____]]
SD-03 Product Data
Corner Guards; G [, [_____]]
Wall Guards (Bumper Guards); G [, [_____]]
SECTION 10 26 00 Page 2
Door Protectors; G [, [_____]]
Wall Covering/Panels; G [, [_____]]
[ Recycled content for aluminum component of corner guards; S ]
[ Recycled content for steel component of corner guards; S ]
[ Recycled content for aluminum component of wall guards, Combination Handrail/Wall guard and handrails; S ]
[ Recycled content for aluminum component of wall guards/bed locators;
S]
[ Recycled content for aluminum component of combination handrail/wall guards; S ]
[ Recycled content for aluminum component of handrails; S ]
SD-04 Samples
Finish; G [, [_____]]
SD-06 Test Reports
Corner Guards
Wall Guards (Bumper Guards)
Door Protectors
Wall Covering/Panels
SD-07 Certificates
Corner Guards
Wall Guards (Bumper Guards)
Door Protectors
[ Indoor air quality for wall covering/panels; S ]
[ Indoor air quality for adhesives; S ]
1.3 CERTIFICATIONS
1.3.1 Indoor Air Quality
1.3.1.1 Wall Covering/Panels
Provide sheet and high impact resistant resilient materials certified to meet indoor air quality requirements by UL 2818 (Greenguard) Gold, SCS Global Services Indoor Advantage Gold or provide certification or validation by other third-party program that products meet the requirements of this section. Provide current product certification documentation from certification body. When product does not have certification, provide validation that product meets the indoor air
SECTION 10 26 00 Page 3 quality product requirements cited herein.
1.3.1.2 Adhesives and Sealants
Provide products certified to meet indoor air quality requirements by UL 2818 (Greenguard) Gold, SCS Global Services Indoor Advantage Gold or provide certification or validation by other third-party program that products meet the requirements of this section. Provide current product certification documentation from certification body When product does not have certification, provide validation that product meets the indoor air quality product requirements cited herein..
1.4 DELIVERY, STORAGE, AND HANDLING
Deliver materials to the project site in manufacturer's original unopened containers with seals unbroken and labels and trademarks intact. Keep materials dry, protected from weather and damage, and stored under cover.
Materials must be stored at approximately 70 degrees F for at least 48 hours prior to installation.
1.5 WARRANTY
Provide manufacturer's standard performance guarantees or warranties that extend beyond a 1 year period.
PART 2 PRODUCTS
2.1 STANDARD PRODUCTS
To the maximum extent possible, corner guards, door and door frame protectors, wall guards (bumper guards), wall panels and wall covering must be the standard products of a single manufacturer and must be furnished as detailed. Drawings show general configuration of products required, and items differing in minor details from those shown will be acceptable.
2.1.1 Resilient Material
Provide resilient material consisting of high impact resistant extruded acrylic vinyl, polyvinyl chloride, or injection molded thermal plastic conforming to the following:
2.1.1.1 Minimum Impact Resistance
Minimum impact resistance must be 18 ft-lbs/sq. inch when tested in accordance with ASTM D256, (Izod impact, ft-lbs per sq inch notched).
2.1.1.2 Fire Rating
Fire rating must be Class 1 when tested in accordance with ASTM E84, having a maximum flame spread of 25 and a smoke developed rating of 450 or less. Material must be rated self extinguishing when tested in accordance with ASTM D635. Material must be labeled and tested by an approved nationally known testing laboratory. Resilient material used for protection on fire rated doors and frames must be listed by the testing laboratory performing the tests. Resilient material installed on fire rated wood/steel door and frame assemblies must have been tested on similar type assemblies. Test results of material tested on any other combination of door/frame assembly will not be acceptable.
SECTION 10 26 00 Page 4
2.1.1.3 Integral Color
Colored components must have integral color and must be matched in accordance with SAE J1545 to within plus or minus 1.0 on the CIE-LCH scales.
2.1.1.4 Chemical and Stain Resistance
Materials must be resistant to chemicals and stains reagents in accordance with ASTM D543.
2.1.1.5 Fungal and Bacterial Resistance
Materials must be resistant to fungi and bacteria in accordance with ASTM G21, as applicable.
2.2 CORNER GUARDS
2.2.1 Resilient Corner Guards
Corner guard units must be [flush mounted] [surface mounted] type, radius formed to profile shown. Corner guards must [extend from floor to ceiling.] [be [_____] feet high.] Mounting hardware, cushions, and base plates must be furnished. Assembly must consist of a snap-on corner guard formed from high impact resistant resilient material, mounted on a continuous aluminum retainer. Extruded aluminum retainer must conform to ASTM B221, alloy 6063, temper T5 or T6. Provide aluminum components that contain a minimum of 35 percent recycled content. Provide data identifying percentage of recycled content for aluminum component of corner guards. Flush mounted type guards must act as a stop for adjacent wall finish material. Factory fabricated end closure caps must be furnished for top and bottom of surface mounted corner guards. Flush mounted corner guards installed in fire rated wall must maintain the rating of the wall. Insulating materials that are an integral part of the corner guard system must be provided by the manufacturer of the corner guard system. Exposed metal portions of fire rated assemblies must have a paintable surface.
2.2.2 Stainless Steel Corner Guards
Stainless steel corner guards must be fabricated of [ 16 gauge][ 18 gauge] thick material conforming to ASTM A240/A240M , type 302 or 304. Provide stainless steel base material that contains a minimum of 60 percent recycled content. Provide data identifying percentage of recycled content for steel component of corner guards. Corner guards must [extend from floor to ceiling.] [be [_____] feet high.] Corner guard must be formed to dimensions shown.
2.3 WALL GUARDS (BUMPER GUARDS)
2.3.1 Wall Guards, Combination Handrail/Wall Guards and Handrails
Wall guards, combination handrail/wall guards, and handrails must be provided with prefabricated end closure caps, inside and outside corners, concealed splices, cushions, mounting hardware and other accessories standard with the manufacturer. Extruded aluminum retainers must conform to ASTM B221, alloy 6063, temper T5 or T6.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .