08.1 Revised DWGS - Replace Storefront - 2271 2272 2273 PDPG25013.pdf

PDF 1 MB Posted

Attached to
REPLACE EXTERIOR DOORS
Solicitation number
W50S74-26-Q-A021
Issued by

About this file

This document is a set of architectural drawings and construction specifications for a storefront replacement project at March Air Reserve Base in California, prepared by the 163 Civil Engineering Squadron of the California Air National Guard.

The project involves replacing storefronts in three buildings (2271, 2272, and 2273) at March Air Reserve Base. Building 2271 requires replacement of multiple storefronts with new units featuring mullion keypads and electronic strikes, new 120V power distribution to access control systems with battery backup above T-bar ceiling, and relocation of wall-mounted notification displays to ceiling mounts at cased heads. Building 2272 includes replacement of a pair of doors with a single unit. Building 2273 requires similar storefront replacements with keypad and electronic strike systems. The electrical work involves installing 4SD and 1GD metal boxes, mud rings, stainless steel cover plates, and ensuring all conduit is concealed from view. Specific installation heights are detailed (such as +36", +48", +84", +120") for power outlets, strike mechanisms, and keypads. The drawings include floor plans for each building showing replacement locations, entry control points with detailed electrical schematics, and photographic references of existing conditions. Notes specify that boxes must be flushed in walls and ceilings, security systems will be installed by others, and all box locations must be verified prior to construction. The project date is marked as 1 September 2026.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VISITOR CENTER

INSPECTION BUILDING

GATE

AREA PLAN

REPLACE STOREFRONT 2271 2272 2273

MARCH AIR RESERVE BASE CA 2271

11 SEP 2026

20'10'

CALIFORNIA AIR NATIONAL GUARD

163 CIVIL ENGINEERIN SQUADRON

MARCH AIR RESERVE BASE

N

FLOOR PLAN 3

OF 11202

BUILDING 2271

30'

71-1

71-2

71-2.1

71-3

71-6

71-5

71-4

71-3.1 71-4.1

REPLACE STOREFRONT 2271 2272 2273

EE

E

SEE ENLARGED PLAN

EXISTING HM

LEGEND

E

REPLACE

DEMO

MULLION KEYPAD & ELEC STRIKE.

PROVIDE 120V PWR TO ACCESS

CTR PWR SUPPLY W/ BATTERY

BACKUP ABOVE TBAR CLG

20'10'

163 CIVIL ENGINEERIN SQUADRON

MARCH AIR RESERVE BASE

N

OF 11 202

BUILDING 2271

30' 3REPLACE STOREFRONT 2271 2272 2273

LEGEND

4SD MTL BOX

1GD MTL BOX

1" EMT W/

PULL CORD

+36" 120V 20A DUPLEX PWR REC

ADJ TO COM BOX, DEDICATED CKT

(ERP1 -2, 4, OR 6). ISOLATE OFFICE

OTHER 2 CKTS AS REQD

+48" WP

+120" & DN TO +36"

CLG

+48" TO STRIKE &

PWR ABOVE CLG

+120"

EXISTING

ELEC PLAN

+84"

CLG

NOTES

1. FLUSH BOXES IN WALLS & CLGS

2. PROVIDE MUD RINGS & SS COVER PLATES

3. NO EXPOSED CONDUIT TO VIEW

3. VERIFY BOX LOCATIONS PRIOR W/ GOV

4. SECURITY SYSTEM BY OTHERS

71-4

71-4.1

MNT KEY PAD ON WALL BOX

COVER, NOT MULLION.

E

+36"

163 CIVIL ENGINEERIN SQUADRON

MARCH AIR RESERVE BASE

N

FLOOR PLAN

20220'10' 30'

72-2 72-1

72-2.1

72-1.1

72-5

72-4

72-3

72-5.1

72-4.1

72-3.1

E

REPLACE

DEMO

MULLION KEYPAD & ELEC STRIKE.

PROVIDE 120V PWR TO ACCESS

CTR PWR SUPPLY W/ BATTERY

BACKUP ABOVE TBAR CLG

E

LEGEND

REPLACE PAIR

W/ SINGLE

MARCH AIR RESERVE BASE

N

FLOOR PLAN

BUILDING 2273

20'10' 30'

73-1.1 73-273-1

73-2.1

REPLACE STOREFRONT 2271 2272 2273

E

REPLACE

DEMO

MULLION KEYPAD & ELEC STRIKE.

PROVIDE 120V PWR TO ACCESS

CTR PWR SUPPLY W/ BATTERY

BACKUP ABOVE TBAR CLG

E

LEGEND

MARCH AIR RESERVE BASE 202

BUILDING 2271

71-171-371-3.1 71-2.1 71-2

71-471-6 71-6 71-5 71-5 71-4.1

REPLACE STOREFRONT 2271 2272 2273

DEMO ELEC

BACK TO

WALL BOX

ABOVE

DEMO ELEC

BACK TO

WALL BOX

ABOVE

RELOCATE WALL

MNT NOTIFICATION

DISPLAY TO CLG MNT

AT CASED HEAD

RELOCATE WALL

MNT NOTIFICATION

DISPLAY TO CLG MNT

AT CASED HEAD

MARCH AIR RESERVE BASE 202

BUILDING 2271

72-172-2.172-372-3.1 72-2 72-1.1

72-472-5.1 72-5 72-4.1

REPLACE STOREFRONT 2271 2272 2273

MARCH AIR RESERVE BASE 202

BUILDING 2271

73-173-2.1 73-2 73-1.1

REPLACE STOREFRONT 2271 2272 2273

EXISTING CARPET

File details come from the government source that posted it. Updated .