RFI__79_-_144_-_AS119_-_HOUSE_F_-_REFLECTED_CEILING_PLAN.pdf
PDF 807 KB Posted
- Attached to
- VAMC PERRY POINT, MD CLC
- Solicitation number
- VA101-16-R-0086
About this file
RFI 79
View the file
Other files
Show 40 more
Latest 50 of 66 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AS201
AS201
AS201
A.F.F.
9'-0"
A.F.F.
9'-0"
A.F.F.
9'-0"
A.F.F.
9'-4"
A.F.F.
8'-8"
A.F.F.
8'-0"
A.F.F.
8'-0"
A.F.F.
9'-0"
A.F.F.
9'-0"
A.F.F.
8'-0"
A.F.F.
9'-0"
A.F.F.
9'-0"
A.F.F.
10'-8"
A.F.F.
10'-6"
A D N R
H J
C F QB C.1 E
G K N.9M
3.5
7.3
L
09 51 00.A109 51 00.A1
09 51 00.A1 09 51 00.A1
09 51 00.A1 09 51 00.A1
09 51 00.A1
09 51 00.A1 09 51 00.A1
09 51 00.A1
A.1 Q.9
A.F.F.
8'-7 3/8"
A.F.F.
9'-0"
A.F.F.
9'-0"
A.F.F.
8'-8"
A.F.F.
8'-7 3/8" A.F.F.
8'-0"
A.F.F.
8'-0"
A.F.F.
8'-8"
A.F.F.
8'-1"
A.F.F.
8'-1"
A.F.F.
9'-0"
A.F.F.
8'-7 3/8"
A.F.F.
8'-0"
A.F.F.
8'-7 3/8"
A.F.F.
8'-8"
A.F.F.
8'-0"
A.F.F.
8'-1"
A.F.F.
8'-0"
A.F.F.
9'-0"
A.F.F.
8'-3"
A5185A
A5185A
A5185A
A5185A
A5185A
A5185A
A5185A
A5185B A5185A
A5185A A5185A
A5185A A5185A
A5185A
A5185A
A5185A
A5185A
A5185A
A5185A
A5185BA5185A
A5185AA5185A
A5185A
A5185C A5185C
A.F.F.
8'-3"
A.F.F.
9'-0"
A.F.F.
9'-0"
A.F.F.
9'-0"
A.F.F.
8'-0"
A.F.F.
8'-0"
A.F.F.
8'-0"
A.F.F.
8'-0"
A.F.F.
8'-0" A.F.F.
8'-7 3/8"
A.F.F.
8'-1"
A.F.F.
8'-8"
A.F.F.
8'-8"
A.F.F.
8'-1"
A.F.F.
8'-8"
A.F.F.
8'-3"
A.F.F.
8'-7 3/8"
26 05 11.A1
11 73 00.A1
11 73 00.A2
AS118
2'- 6"
8" 1'-
AS
AS118
8" 2'-0"
2'-8"
AS117
A.F.F.
7'-8"
AS117
3'-
3'- 2"
8"
2'-2"
2'- 2"
.00
2'-4"
1'-8" 8"
AS117
AS117
AS117
AS126
AS313
BULKHEAD
AS609
AS302
AS302
AS609
P
2 X 4 RECESSED FLUORESCENT LIGHT FIXTURE
EMERGENCY LIGHTING
2 X 2 RECESSED FLUORESCENT LIGHT FIXTURE
EMERGENCY LIGHTING
SUPPLY AIR DIFFUSER
RETURN AIR DIFFUSER
RECESSED CAN TYPE FLUORESCENT LIGHT
FIXTURE
EXIT LIGHT
2 X 4 RECESSED FLUORESCENT LIGHT
FIXTURE
2 X 2 RECESSED FLUORESCENT LIGHT
FIXTURE
DRYWALL
CEILING
2 x 2 ACCUSTIC
CEILING TILE
REFLECTED
CEILING LEGEND
FLUORESCENT LIGHT FIXTURE, INDUSTRIAL TYPE
A.F.F.
8'-8"
A.F.F.
9'-0"
09 29 00.B2
09 22 16.A109 22 16.A1 09 51 00.B1
ATTACH TO
STRUCTURE ABOVE
09 51 00.B1
09 51 00.A1
A.F.F.
9'-0"
A.F.F.
8'-8"
A.F.F.
9'-0"
09 22 16.A109 22 16.A1
ATTACH TO
STRUCTURE
ABOVE
6"
09 29 00.B2
09 22 16.A109 22 16.A109 22 16.A1 09 51 00.B1 09 51 00.B1
09 29 00.B2 A.F.F.
8'-8" A.F.F.
9'-0" A.F.F.
9'-0"
ATTACH TO STRUCTURE ABOVE
CORRIDOR
K-G01
A.F.F.
8'-8"
A.F.F.
9'-0"
A.F.F.
8'-7 3/8"
1'-0" 4'-6"
A.F.F.
9'-0"
A.F.F.
8'-7 3/8"
A.F.F.
8'-8"
A.F.F.
8'-8"
1'-0" 4'-6"
NOTES:
• ALL CEILING HEIGHTS ARE 9'-0" U.O.N.
• SEE FINISH SCHEDULE FOR FINISH AND PAINT COLORS.
• SEE ELECTRICAL DRAWINGS FOR LIGHT LOCATIONS AND DETAILS.
• SEE MECHANICAL DRAWINGS FOR LOCATIONS AND DETAILS.
A.F.F.
9'-4"
09 22 16.A1
09 22 16.A6
09 29 00.C1
09 22 16.A5 09 29 00.B1
06 20 00.F1
09 51 00.A1
402.298.8260 - FAX 402.298.8290
PLATTSMOUTH, NEBRASKA 68048
12917 - 30TH AVENUE
COST ESTIMATING
410.323.0600 - FAX 410.377.2543
BALTIMORE, MARYLAND 21209
1416 CLARKVIEW ROAD, SUITE 500
MECHANICAL / ELECTRICAL CONSULTING ENGINEERING
CIVIL & STRUCTURAL ENGINEERING
10710 GILROY ROAD
HUNT VALLEY, MARYLAND 21031
443.589.2400 - FAX 443.589.2401
FIRE PROTECTION ENGINEERING
8815 CENTRE PARK DR., SUITE 200
COLUMBIA, MARYLAND 21045
410.750.2246 - FAX 410.750.2588
AUTOMATIC TRANSPORT ENGINEERING
182 THOMOS JOHNSON DR. SUITE 200
FREDERICK, MARYLAND 21702
301.662.8112 - FAX 301.662.8117
PLANTREE CONSULTANT
8055 CHORDON RD.
KIRTLAND, OHIO 44094
440.256.1880 - FAX 440.256.1881
CULTURAL RESOURSES CONSULTANT
535 NORTH CHURCH ST.
WEST CHESTER, PENNSYLVANIA 19380
610.436.9000 - FAX 610.436.8468
FULLY SPRINKLERED
FINAL CONSTRUCTION DOCUMENTS
VA FORM 08-6231
on e ei gh th in ch o ne fo ot th re e in ch es o ne fo ot on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r i nc h on e fo ot
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS:
LIVING CENTER
PERRY POINT VA MEDICAL CENTER
ARCHITECT/ENGINEERS: REPLACEMENT COMMUNITY 512-173
08/26/16
Office of Construction and Facilities Management
B
A
C
D
E
F
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
BUILDING COST CONSULTANTS
& ASSOCIATES, INC.
BURDETTE KOEHLER MURPHY
CENTURY ENGINEERING, INC.
KOFFEL ASSOCIATES, INC. ROBERT L. SEYMOUR ASSOCIATES I.D.E.A.S., INC.
JOHN MILNER ASSOCIATES, INC.
Department of Veterans Affairs
Bel Air, Maryland 21015-1436 fax 410.836.6611 2215 Conowingo Rd, Suite 101 410.803.2141
POLT DESIGN GROUP
www.polt-design.com
ENGINEERING
PLANNING
ARCHITECTURE
WP/ DW/ DK
LOWER LEVEL HOUSE
REFLECTED CEILING PLAN
AS117
JK/ CE/ BPCAJ
SCALE: 1/8" = 1'-0"AS117
1 LOWER LEVEL HOUSE RCP
C
L N
J GM K
H
KEY PLAN
I
SCALE: 1/4" = 1'-0"
2'-0" 4'-0"0 8'-0"
KEYNOTE LEGEND
DIVISION DESCRIPTION
06 20 00.F1 SCRIBE COVE MOLDING
07 21 13.B4 6" BATT INSULATION - R19
09 22 16.A1 3 5/8" METAL STUD @ 16" OC
09 22 16.A5 1 5/8" METAL STUD @ 16" OC
09 22 16.A6 6" METAL STUD @ 16" OC
09 29 00.B1 5/8" GYPSUM WALLBOARD
09 29 00.B2 5/8" GYPSUM WALLBOARD - 1 LAYER
09 29 00.C1 5/8" GYPSUM WALLBOARD - TYPE X
09 51 00.A1 ACT 2'-0" X 2'-0"
09 51 00.B1 DRYWALL SUSPENSION SYSTEM
11 73 00.A1 650LB CAPACITY PATIENT LIFT SYSTEM AT RESIDENT BEDROOM - CEILING MOUNTED 11 73 00.A2 1,000LB CAPACITY PATIENT LIFT SYSTEM AT BARIATRIC BEDROOM - CEILING MOUNTED
26 05 11.A1 SEE ELECTRICAL DRAWINGS
SCALE: 1 1/2" = 1'-0"AS117
2 ENLARGED CEILING DETAIL - GWB - TYPICAL
SCALE: 1 1/2" = 1'-0"AS117
ENLARGED CEILING DETAIL - GWB TO ACT -
TYPICAL
SCALE: 1 1/2" = 1'-0"
4" 8"0 16"
SCALE: 1 1/2" = 1'-0"AS117
ENLARGED CEILING DETAIL - CORRIDOR GWB -
TYPICAL
SCALE: 1/4" = 1'-0"AS117
5 TYPICAL CEILING LAYOUT AT LIGHT WELL LONG
SCALE: 1/4" = 1'-0"AS117
6 TYPICAL CEILING LAYOUT AT LIGHT WELL
SCALE: 1/8" = 1'-0"
4'-0" 8'-0"0 16'-0"
NOTE:
DETAILS TYPICAL FOR ALL
HOUSES
PLAN NORTH
TRUE NORTH
SCALE: 3/4" = 1'-0"AS117
7 ENLARGED CEILING DETAIL - LAUNDRY
1 RCP REVISION 11/21/16
| Sheets |
| AS117 - LOWER LEVEL HOUSE REFLECTED CEILING PLAN |
File details come from the government source that posted it. Updated .