305 - S703.pdf

PDF 199 KB Posted

Attached to
VAMC PERRY POINT, MD CLC
Solicitation number
VA101-16-R-0086
Issued by

About this file

RFI 11

View the file

Other files

File Type Posted
VA101-16-R-0086_A00008.pdf PDF
P07_-_WAGE_DETERMINATION_11-18-16.pdf PDF
RFI__58_-_085653.pdf PDF
RFI__79_-_144_-_AS119_-_HOUSE_F_-_REFLECTED_CEILING_PLAN.pdf PDF
VA101-16-R-0086_A00007.pdf PDF
RFI__50_-084413.pdf PDF
RFI__75_-AS606_-_TYPICAL_UPPER_LEVEL_HOUSE_STOREFRONT__ELEVATIONS.pdf PDF
RFI__70_-_AS201_-_LOWER_LEVEL_HOUSE_-_ELEVATIONS.pdf PDF
VA101-16-R-0086_A00006.pdf PDF
RFI_32_and_71_-Pg_5_of_96.docx DOCX document
RFI__19_-_AQ104_-_FIRST_FLOOR_COMMUNITY_CENTER_FURNITURE_ _EQUIPMENT_PLAN.pdf PDF
RFI__26_-_096723-20_REV.pdf PDF
RFI__19_-_AQ105_-_SECOND_FLOOR_COMMUNITY_CENTER_FURNITURE_ _EQUIPMENT_PLAN.pdf PDF
RFI___19_-AQ101_-_LOWER_LEVEL_HOUSE_FURNITURE_ _EQUIPMENT_PLAN.pdf PDF
VA101-16-R-0086_A00005-signed.pdf PDF
RFI__19_-_AQ103_-_HOUSE_F_-_FURNITUR_ _EQUIPMENT_PLAN.pdf PDF
RFI___19_-_I109_-_LOWER_LEVEL_WAYFINDING_____PLAN_-_B.pdf PDF
RFI__19_-_I108_-_LOWER_LEVEL_WAYFINDING_____PLAN_-_A.pdf PDF
RFI__24_-_Remote_Fill_Station_EarthSafe.pdf PDF
285 - S304.pdf PDF
RFI__10_Perry_Point_CLC_Soil_Borings_Plan-SB-01.pdf PDF
275 - SF110.pdf PDF
302 - S503.pdf PDF
260 - SB102.pdf PDF
301 - S502.pdf PDF
267 - SF102.pdf PDF
RFI__10_Perry_Point_VA_Community_Living_Center-_Geotech._Report_(Rev._2-9-15).pdf PDF
268 - SF103.pdf PDF
274 - SF109.pdf PDF
261 - SB103.pdf PDF
293 - S312.pdf PDF
286 - S305.pdf PDF
VA101-16-R-0086_A00004.pdf PDF
294 - S313.pdf PDF
304 - S702.pdf PDF
VA101-16-R-0086_A00003.pdf PDF
RFI__6_-_416_-_FX110_-_MALL_-_LOWER_LEVEL_PLAN_-_AREA_A_-_FIRE_SPRINKLER.pdf PDF
RFI__8_-ATTACHMENT_A.docx DOCX document
VA101-16-R-0086_A00002-signed.pdf PDF
RFI___9_ATTACHMENT_B.docx DOCX document
RFI__3_-_117300_REV.pdf PDF
VA101-16-R-0086_A00001.pdf PDF
Attendees.pdf PDF
Pre-bid_Presentation_Part_1.pdf PDF
Pre-bid_Presentation_Part_2.pdf PDF
J A_VA101-16-R-0086_redacted.pdf PDF
VOLUME_1A.zip ZIP file
VOLUME_1K.zip ZIP file
VOLUME_1J.zip ZIP file
VOLUME_1I.zip ZIP file
Show 40 more

Latest 50 of 66 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

HOUSE F COLUMN SCHEDULE

LOWER LEVEL LOWER LEVEL

13' - 1 1/4" 13' - 1 1/4"

UPPER LEVEL UPPER LEVEL

26' - 1 1/4" 26' - 1 1/4"

U.L. ROOF U.L. ROOF

40' - 7 1/4" 40' - 7 1/4"

Column Locations A-2 A-4 A-6 A-7 A-8 A-10 A-12 B-3 B-4 B-6 C-2 C-6 C-7 C-8 C-9 C-11 C-12 C.5-3 C.5-4 D-1 D-6 D-7 D-8 D-9 D-11 D-12 D.8-11.1 D.8-11.4 D.8-12 E-3 E-4 F-6 F.1-0.8 G-0.8 G-3 G-4 G-5 H-2.6 H-3.9

HS

S6 x6 x1

/2

HS

S6 x6 x5

/8

HS

S6 x6 x1

/2

HS

S6 x6 x3

/8

HS

S6 x6 x5

/8

HS

S6 x6 x1

/2

HS

S6 x6 x1

/2 HS

S6 x6 x1

/4

HS

S6 x6 x1

/4

HS

S6 x6 x1

/2

HS

S6 x6 x1

/2

HS

S6 x6 x5

/8

HS

S6 x6 x1

/4

HS

S6 x6 x5

/16

HS

S6 x6 x5

/16

HS

S6 x6 x5

/16

HS

S6 x6 x1

/4

HS

S6 x6 x1

/4

HS

S6 x6 x5

/16

HS

S6 x6 x5

/8

HS

S6 x6 x1

/4

HS

S6 x6 x3

/8

HS

S6 x6 x5

/16

HS

S6 x6 x3

/8

HS

S6 x6 x1

/4

HS

S6 x6 x1

/4

HS

S6 x6 x1

/4

HS

S6 x6 x1

/4

HS

S6 x6 x1

/4

HS

S6 x6 x1

/4

HS

S6 x6 x1

/4

HS

S6 x6 x1

/4

HS

S6 x6 x1

/4

PIER

BASE PLATES

PIER

BASE PLATESBP-4 BP-3BP-2BP-2BP-2BP-2BP-2BP-3BP-3BP-3BP-4BP-2BP-3BP-2BP-2BP-2BP-3BP-2BP-3BP-3BP-3BP-2BP-2BP-3BP-3BP-3BP-3BP-3 BP-2 BP-3BP-3 BP-2 BP-3 P18 P18 P18 P18 P18 P18

P18 P18 P18 P18 P18 P18 P18 P18 P18 P18 P18 P18 P18 P18 P18 P18

LOAD (KIPS) LOAD (KIPS)43 47 62 60 80 104 52 70 68 54 41 61 73 87 69 101 64 44 45 41 64 26 24 24 31 20 45 46 8 13 22 33 27

HS

S6 x6 x1

/2

HS

S6 x6 x1

/2

BP-2 BP-2BP-3

28 20 20

HS

S4 x4 x1

/4

HS

S4 x4 x1

/4

HS

S4 x4 x1

/4HS

S6 x6 x1

/4

BP-1 BP-1 BP-1

MP16MP18 MP16P18 P18 P18 P18 P18 P18 P18 MP2044 MP2032

PIER TYPES

A B C D

ALTERNATE LOCATIONS OF HOOKS WHEN PLACING SUCCESIVE TIES

CLASS B

LAP SPLICE

402.298.8260 - FAX 402.298.8290

PLATTSMOUTH, NEBRASKA 68048

12917 - 30TH AVENUE

COST ESTIMATING

410.323.0600 - FAX 410.377.2543

BALTIMORE, MARYLAND 21209

1416 CLARKVIEW ROAD, SUITE 500

MECHANICAL / ELECTRICAL CONSULTING ENGINEERING

CIVIL & STRUCTURAL ENGINEERING

10710 GILROY ROAD

HUNT VALLEY, MARYLAND 21031

443.589.2400 - FAX 443.589.2401

FIRE PROTECTION ENGINEERING

8815 CENTRE PARK DR., SUITE 200

COLUMBIA, MARYLAND 21045

410.750.2246 - FAX 410.750.2588

AUTOMATIC TRANSPORT ENGINEERING

182 THOMOS JOHNSON DR. SUITE 200

FREDERICK, MARYLAND 21702

301.662.8112 - FAX 301.662.8117

PLANTREE CONSULTANT

8055 CHORDON RD.

KIRTLAND, OHIO 44094

440.256.1880 - FAX 440.256.1881

CULTURAL RESOURSES CONSULTANT

535 NORTH CHURCH ST.

WEST CHESTER, PENNSYLVANIA 19380

610.436.9000 - FAX 610.436.8468

FULLY SPRINKLERED

FINAL CONSTRUCTION DOCUMENTS

VA FORM 08-6231

on e ei gh th in ch o ne fo ot th re e in ch es o ne fo ot on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r i nc h on e fo ot

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS:

LIVING CENTER

PERRY POINT VA MEDICAL CENTER

ARCHITECT/ENGINEERS: REPLACEMENT COMMUNITY 512-173

08/26/16

Office of Construction and Facilities Management

B

A

C

D

E

F

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

BUILDING COST CONSULTANTS

& ASSOCIATES, INC.

BURDETTE KOEHLER MURPHY

CENTURY ENGINEERING, INC.

KOFFEL ASSOCIATES, INC. ROBERT L. SEYMOUR ASSOCIATES I.D.E.A.S., INC.

JOHN MILNER ASSOCIATES, INC.

Department of Veterans Affairs

Bel Air, Maryland 21015-1436 fax 410.836.6611 2215 Conowingo Rd, Suite 101 410.803.2141

POLT DESIGN GROUP

www.polt-design.com

ENGINEERING

PLANNING

ARCHITECTURE

WP/ DW/ DK

HOUSE F COLUMN SCHEDULE

S703

BASE PLATE SCHEDULE

Mark Size

(inches) Anchor Bolts Bolt Grade (ASTM F1554) BP-1 10x10x3/4 (4) 3/4"Ø x 9" EMBEDMENT 36 BP-2 12x12x3/4 (4) 3/4"Ø x 9" EMBEDMENT 36 BP-3 12x12x1 (4) 1"Ø x 12" EMBEDMENMT 36 BP-4 12x12x1 (4) 1 3/8"Ø x 14" EMBEDMENT 36

CONCRETE PIER SCHEDULE

Pier Number Size (inches) Reinforcing (verts & ties) Pier Type P18 18 x 18 4#7 VERT w/#3@8 TIES A

MASONRY PIER SCHEDULE

Pier Number Size (inches) Reinforcing (verts & ties) Pier Type MP16 16 x 16 4#5 VERT w/HORIZ TRUSS REINF @ 8" A (SIM) MP18 18 x 18 4#6 VERT w/HORIZ TRUSS REINF @ 8" A (SIM)

MP2032 20 x 32 SEE 2/SB103 MP2044 20 x 44 SEE 2/SB103

Sheets
S305 - HOUSE F SECTIONS
S503 - HOUSE F LATERAL FRAMES
S703 - HOUSE F COLUMN SCHEDULE
SB103 - HOUSE F FOUNDATION PLAN
SF103 - HOUSE F ATTIC / GREEN ROOF FRAMING PLAN
SF110 - HOUSE F MAIN ROOF FRAMING PLAN

File details come from the government source that posted it. Updated .