RFI__6_-_416_-_FX110_-_MALL_-_LOWER_LEVEL_PLAN_-_AREA_A_-_FIRE_SPRINKLER.pdf
PDF 665 KB Posted
- Attached to
- VAMC PERRY POINT, MD CLC
- Solicitation number
- VA101-16-R-0086
About this file
RFI 6 FX110
View the file
Other files
Show 40 more
Latest 50 of 66 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RE
FE
R
T O
FX
1 1
FO
R
CO
NT
IN
UA
TI
ON
2.5
4.5
A
B
106 107
1-38 117
121120
GENERAL NOTES: DRAWING NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
THIS IS NOT A FABRICATION DRAWING. PIPING AND SYSTEM
COMPONENT LOCATIONS ARE APPROXIMATE. VERIFY ALL
LOCATIONS IN THE FIELD. CONTRACTOR SHALL PROVIDE/ INSTALL
ADDITIONAL COMPONENTS AS REQUIRED TO COORDINATE THE
INSTALLATION WITH STRUCTURAL ELEMENTS AND MECHANICAL/
ELECTRICAL SYSTEMS.
PROVIDE SPRINKLER PROTECTION THROUGHOUT IN ACCORDANCE
WITH NFPA 13.
REFER TO SHEET FX001 FOR SPRINKLER SYSTEM GENERAL
NOTES, SYMBOLS, ABBREVIATIONS, AND LINETYPES.
SEE DRAWING FX002 FOR SPRINKLER ZONING DIAGRAM.
REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES AND
HEIGHT.
REFER TO ROOM LIST FOR HAZARD CLASSIFICATIONS. ALL AREAS
SHALL BE PROTECTED AS LIGHT HAZARD UNLESS INDICATED
OTHERWISE. ATTICS SHALL BE PROTECTED AS ORDINARY HAZARD
GROUP 1
UNO, ALL SPRINKLER ARMOVERS AND DROPS ARE 1".
WHERE INDICATED, UPRIGHT SPRINKLERS SHALL BE PROVIDED
WITH A PROTECTIVE CAGE. CAGE SHALL BE AN APPROVED
ACCESSORY FROM THE SPRINKLER MANUFACTURER.
UNO, ALL SPRINKLERS SHALL BE UL AND FM LISTED QUICK
RESPONSE.
PROVIDE TAMPER SWITCHES FOR ALL CONTROL VALVES.
SPRINKLER ZONE N ZONE CONTROL ASSEMBLY.
SPRINKLER ZONE N - ATTIC ZONE CONTROL ASSEMBLY.
SPRINKLER ZONE M ZONE CONTROL ASSEMBLY.
SPRINKLER ZONE L ZONE CONTROL ASSEMBLY.
NOT USED
6" FEED MAIN.
4" SPRINKLER ZONE MALL - LOWER CROSS MAIN..
2-1/2" HOSE CONNECTION.
PROVIDE STANDARD RESPONSE INTERMEDIATE TEMPERATURE
(200°F) SIDEWALL SPRINKLER NO MORE THAN 2 FEET FROM
BOTTOM OF ELEVATOR PIT. PROVIDE GUARD ON SPRINKLER.
PROVIDE STANDARD RESPONSE INTERMEDIATE TEMPERATURE
(200°F) SPRINKLERS IN ELEVATOR MACHINE ROOM.
2" UP TO SERVE SPRINKLERS ON LEVEL ABOVE. REFER TO SHEET
FX113.
TO SPRINKLER BENEATH LOWER STAIRS LANDING
402.298.8260 - FAX 402.298.8290
PLATTSMOUTH, NEBRASKA 68048
12917 - 30TH AVENUE
COST ESTIMATING
410.323.0600 - FAX 410.377.2543
BALTIMORE, MARYLAND 21209
1416 CLARKVIEW ROAD, SUITE 500
MECHANICAL / ELECTRICAL CONSULTING ENGINEERING
CIVIL & STRUCTURAL ENGINEERING
10710 GILROY ROAD
HUNT VALLEY, MARYLAND 21031
443.589.2400 - FAX 443.589.2401
FIRE PROTECTION ENGINEERING
8815 CENTRE PARK DR., SUITE 200
COLUMBIA, MARYLAND 21045
410.750.2246 - FAX 410.750.2588
AUTOMATIC TRANSPORT ENGINEERING
182 THOMOS JOHNSON DR. SUITE 200
FREDERICK, MARYLAND 21702
301.662.8112 - FAX 301.662.8117
PLANTREE CONSULTANT
8055 CHORDON RD.
KIRTLAND, OHIO 44094
440.256.1880 - FAX 440.256.1881
CULTURAL RESOURSES CONSULTANT
535 NORTH CHURCH ST.
WEST CHESTER, PENNSYLVANIA 19380
610.436.9000 - FAX 610.436.8468
FULLY SPRINKLERED
FINAL CONSTRUCTION DOCUMENTS
VA FORM 08-6231
on e ei gh th in ch o ne fo ot th re e in ch es o ne fo ot on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r i nc h on e fo ot
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS:
LIVING CENTER
PERRY POINT VA MEDICAL CENTER
ARCHITECT/ENGINEERS: REPLACEMENT COMMUNITY 512-173
08/26/16
Office of Construction and Facilities Management
B
A
C
D
E
F
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
BUILDING COST CONSULTANTS
& ASSOCIATES, INC.
BURDETTE KOEHLER MURPHY
CENTURY ENGINEERING, INC.
KOFFEL ASSOCIATES, INC. ROBERT L. SEYMOUR ASSOCIATES I.D.E.A.S., INC.
JOHN MILNER ASSOCIATES, INC.
Department of Veterans Affairs
Bel Air, Maryland 21015-1436 fax 410.836.6611 2215 Conowingo Rd, Suite 101 410.803.2141
POLT DESIGN GROUP
www.polt-design.com
ENGINEERING
PLANNING
ARCHITECTURE
WP/ DW/ DK
MALL - LOWER LEVEL PLAN -
AREA A - FIRE SPRINKLER
FX110
MALL A LOWER LEVEL ROOM LIST
1-23 CORRIDOR
1-38 CORRIDOR
101 CORRIDOR
102 MULTI PURP-3 HEALING ARTS
103 EQUIP.STO. OH2
104 SIGNAL
105 SW-1
106 NM-4
107 BREAK RM
108 DATA
109 DATA
110 DIET.
111 CORRIDOR
112 RAC-1
113 PRVDR-1
114 MEDIA CAFE
115 REFLECTION AREA
116 ELEV. MECH OH1
117 PROVIDER-2
118 CORRIDOR
119 NURSE SPECIALIST
120 SIGNAL
121 DATA
122 ACTIV COORD
123 ACT COORD WKRM
173 MECH OH1
EL-1 ELEV. OH1
ST-1 STAIRS
ST-2 STAIRS
C
L
N I
GM
K H
KEY PLAN
A D
F B
E
J
| Sheets |
| FX110 - MALL - LOWER LEVEL PLAN - AREA A - FIRE SPRINKLER |
File details come from the government source that posted it. Updated .