303 SF
STORAGE
F-216
225 SF
RESIDENT BEDROOM
F-217
225 SF
RESIDENT BEDROOM
F-218
225 SF
RESIDENT BEDROOM
F-219
218 SF
RESIDENT BEDROOM
F-220
225 SF
RESIDENT BEDROOM
F-221
230 SF
RESIDENT BEDROOM
F-222
239 SF
RESIDENT BEDROOM
F-223
270 SF
BARIATRIC BEDROOM
F-224
204 SF
RESIDENT BEDROOM
F-225
222 SF
RESIDENT BEDROOM
F-226 232 SF
RESIDENT BEDROOM
F-227
282 SF
KITCHEN/SERVERY
F-206
72 SF
HAC
F-215
198 SF
HOME STOR.
F-214
60 SF
SU
F-213
68 SF
RESIDENT WC
F-217A
68 SF
RESIDENT WC
F-218A
120 SF
LAUNDRY
F-211
37 SF
CL
F-212
65 SF
BATH STE. WC
F-209A
163 SF
BATHING SUITE
F-209
80 SF
PANTRY
F-207
68 SF
RESIDENT WC
F-219A
68 SF
RESIDENT WC
F-220A
68 SF
RESIDENT WC
F-221A
72 SF
RESIDENT WC
F-222A
71 SF
RESIDENT WC
F-223A
90 SF
BARIATRIC WC
F-24A
68 SF
RES.WC
F-225A
68 SF
RES.WC
F-226A
119 SF
MECH/ ELEC
F-230
73 SF
RES.WC
F-227A
128 SF
HOME OFFICE
F-203
90 SF
MEDS STOR
F-202
65 SF
VESTIBULE
F-201
192 SF
DEN
F-228
58 SF
VIS. WC
F-229
91 SF
EQUIP.STOR
F-208
505 SF
LIVING RM
F-204
373 SF
DINING RM
F-205
22 SF
SC
F-213A
15 SF
ELEC.
F-210
BACKYARD
COURTYARD
1144 SF
CORRIDOR
F-GO1
701 SF
CORRIDOR
F-G02
24 SF
MSD
F-G03
10 SF
CRASH CART
F-G05
233 SF
CORRIDOR
G06
NOTE:
• SEE SHEET AQ102 - UPPER LEVEL HOUSE FURNITURE AND EQUIPMENT PLAN
FOR FURNITURE AND EQUIPMENT LAYOUT OF HOUSE F
• SEE EQUIPMENT LIST FOR ALL EQUIPMENT AND TOILET ACCESSORIES FOR
FINISHED/ INSTALLED RESPONSIBILITIES.
• FOR WALL, BASE, FLOOR AND CASEWORK FINISHES SEE SHEET I112
• SEE SHEET GI113 FOR PARTITION TYPES
LEGEND
GENERAL NOTE:
ALL UPPER HOUSES TO HAVE
SAME LAYOUT FOR HANDRAILS
AND CORNER GUARDS, TYPICAL
CORNER GUARD
HANDRAIL
WALL PROTECTION PANEL
1 1/2" 1 1/2"
6 1 /4"
2'-
" A
FF
HIGH IMPACT ACRYLIC EXTRUSION
ACCENT REVEAL AS SPECIFIED
CONT. WOOD BLOCKING AS REQ'D.
FASTENERS @ 32" O.C. MAX
MOUNTING BRACKET@ 32" O.C. MAX
CONT. ALUM. RETAINER
CONT. VINYL CUSHION
TYPICAL CORNER GUARD
CS ACROVYN: SM-20N
FINISH: 253 PARCHMENT
48" HEIGHT TO BE MOUNTED
ABOVE WALL BASE.
WALL SIZE
VARIES
3"
3"
402.298.8260 - FAX 402.298.8290
PLATTSMOUTH, NEBRASKA 68048
12917 - 30TH AVENUE
COST ESTIMATING
410.323.0600 - FAX 410.377.2543
BALTIMORE, MARYLAND 21209
1416 CLARKVIEW ROAD, SUITE 500
MECHANICAL / ELECTRICAL CONSULTING ENGINEERING
CIVIL & STRUCTURAL ENGINEERING
10710 GILROY ROAD
HUNT VALLEY, MARYLAND 21031
443.589.2400 - FAX 443.589.2401
FIRE PROTECTION ENGINEERING
8815 CENTRE PARK DR., SUITE 200
COLUMBIA, MARYLAND 21045
410.750.2246 - FAX 410.750.2588
AUTOMATIC TRANSPORT ENGINEERING
182 THOMOS JOHNSON DR. SUITE 200
FREDERICK, MARYLAND 21702
301.662.8112 - FAX 301.662.8117
PLANTREE CONSULTANT
8055 CHORDON RD.
KIRTLAND, OHIO 44094
440.256.1880 - FAX 440.256.1881
CULTURAL RESOURSES CONSULTANT
535 NORTH CHURCH ST.
WEST CHESTER, PENNSYLVANIA 19380
610.436.9000 - FAX 610.436.8468
FULLY SPRINKLERED
FINAL CONSTRUCTION DOCUMENTS
VA FORM 08-6231
on e ei gh th in ch o ne fo ot th re e in ch es o ne fo ot on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r i nc h on e fo ot
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS:
LIVING CENTER
PERRY POINT VA MEDICAL CENTER
ARCHITECT/ENGINEERS: REPLACEMENT COMMUNITY 512-173
08/26/16
Office of Construction and Facilities Management
B
A
C
D
E
F
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
BUILDING COST CONSULTANTS
& ASSOCIATES, INC.
BURDETTE KOEHLER MURPHY
CENTURY ENGINEERING, INC.
KOFFEL ASSOCIATES, INC. ROBERT L. SEYMOUR ASSOCIATES I.D.E.A.S., INC.
JOHN MILNER ASSOCIATES, INC.
Department of Veterans Affairs
Bel Air, Maryland 21015-1436 fax 410.836.6611 2215 Conowingo Rd, Suite 101 410.803.2141
POLT DESIGN GROUP
www.polt-design.com
ENGINEERING
PLANNING
ARCHITECTURE
WP/ DW/ DK
HOUSE F - FURNITURE &
EQUIPMENT PLAN
AQ103
JK/ CE/ BPCAJ
SCALE: 1/8" = 1'-0"AQ103
1 FURNITURE & EQUIPMENT PLAN
C
L
N I
GM
K H
KEY PLAN
A D
F B
E
J
SCALE: 1/8" = 1'-0"
4'-0" 8'-0"0 16'-0"
PLAN NORTH
TRUE NORTH
SCALE: 3" = 1'-0"AQ103
2 HANDRAIL MOUNTING DETAIL
SCALE: 3" = 1'-0"AQ103
3 CORNER GUARD DETAIL
1 WALL PROTECTION 11/09/2016
NOTES:
1. WALL PROTECTION PANELS TO BE CS
ACROVYN: .060" THICKNESS HIGH IMPACT
WALL COVERING; 253 PARCHMENT
2. REFER TO SPECIFICATION SECTION
090600 FOR HANDRAIL TYPE AND COLOR.
3. CORNER GUARDS TO BE CS ACROVYN:
SM-20N; 253 PARCHMENT
| Sheets |
| AQ103 - HOUSE F - FURNITURE & EQUIPMENT PLAN |
File details come from the government source that posted it. Updated .