TO 2 PWS Attch 1 Northeast Base Site List BECOS vf7.xlsx
XLSX spreadsheet 31 KB Posted
- Attached to
- BASE REALIGNMENT AND CLOSURE (BRAC) ENVIRONMENTAL CONSTRUCTION AND OPTIMIZATION SERVICES (BECOS) Northeast Region Federal contract opportunity
- Solicitation number
- FA890320R0011
About this file
This document provides details on a Base Realignment and Closure (BRAC) Environmental Construction and Optimization Services (BECOS) Northeast Region contract opportunity. The solicitation seeks proposals for environmental remediation and long-term monitoring services at multiple closed and realigned military installations across the Northeast region, including Griffiss Air Force Base, Loring Air Force Base, Pease Air Force Base, Plattsburgh Air Force Base, and other locations. Services required include operation and maintenance of groundwater treatment systems, landfill capping and monitoring, land use control inspections, five-year reviews, and environmental remediation activities such as soil excavation and vapor mitigation systems. The period of performance is one base year with four option years. The Department of the Air Force Materiel Command Installation and Mission Support Center Installation Contracting Agency will award an Indefinite Delivery Indefinite Quantity (IDIQ) contract with both fixed price and cost reimbursement line items. The solicitation number is FA890320R0011 and proposals are due by the specified response date.
View the file
Other files for this federal contract opportunity
Show all 50
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Northeast
| Region | Base | Site ID | Site Name | Site Alias | Operable Unit (OU) | Regulatory Program | Site Phase | Current Remedy | Type of System | Current Frequency of Monitoring | Notes | Performance Objective | Projected | |
| RC Date | Projected |
SC Date Northeast Griffiss SD052 -01 Apron 2 Chlorinated Plume CERCLA RA-O GW monitoring (MNA), LUC/IC monitoring and Five-Year Review. None Annual Sampling/Report Annual Inspections
| FYR every five years | PFOS/PFOA detected within the site boundaries. Investigation and remediation of PFAS is not included in this TO. | RA-O | FY40 | FY40 | ||||||
| Northeast | Griffiss | SD052 | -02 | Bldg 775, Pumphouse 3 - chlorinated plume aka SS038 | CERCLA | RA-O | GW monitoring, maintain system on standby in operable condition & maintain permit, system decommissioning, LUC/IC monitoring and Five-Year Review | 1 - P&T (Standby) | Annual Sampling/Report |
Annual Inspections
| FYR every five years | GW extraction/ discharge system on standby since 2016; injections completed in 2017 w/ injection pilot study completed in 2019. | RA-O | FY26 | FY26 | ||||||
| Northeast | Griffiss | SD052 | -04 | Landfill 6 Chlorinated Plume | CERCLA | RA-O | GW monitoring, LUC/IC monitoring and Five-Year Review | None | Annual Sampling/Report |
Annual Inspections
| FYR every five years | -Associated with LF009 -Injections completed in 2018. PFOS/PFOA detected within the site boundaries. -Investigation and remediation of PFAS is not included in this TO. | RA-O | FY40 | Indefinite | ||||||
| Northeast | Griffiss | SD052 | -05 | Bld 817 Chlorinated Plume | CERCLA | RA-O | GW monitoring, LUC/IC monitoring and Five-Year Review | None | Annual Sampling/Report |
Annual Inspections
| FYR every five years | Injections completed in 2017. | RA-O | FY40 | FY40 | ||||||
| Northeast | Griffiss | SD052 SVI | -02 | Bldg 775 Site (Bldg 774 & 776) sub-slab vapor mitigation | CERCLA | RA-O | O&M of passive sub-slab vapor mitigation system, monitoring, reporting, LUC/IC monitoring and Five-Year Review | 1 - Vapor Mitigation System on standby, passive system in place | Twice Annual indoor/outdoor air and subslab vapor sampling (heating season) |
Annual Report Annual Inspections
| FYR every five years | -Active mitigation system to be maintained in stand-by mode -SVI cannot reach SC prior to completion of GW cleanup objective. | RA-O | FY26 | FY26 | ||||||
| Northeast | Griffiss | ST006 | Bldg 101 | N/A | CERCLA | RA-O | Quarterly sub-slab SVE system O&M and monitoring; prepare Proposed Plan and ROD amendment for sub-slab SVE; LUC/IC monitoring and Five-Year Review | 1 - Vapor Mitigation System currently inactive pending system evaluation | Quarterly Sampling |
Annual Report Biweekly O&M (system inactive) Annual Inspections
| FYR every five years | -2012 ROD specified LUC/ICs only, however a subslab SVE system was installed/ activated in 2013 to accelerate clean-up but has been inactive since Sept 2017 -Data gap analysis and optimization conducted by current PBR contractor. Results anticipated 2020. | RA-O | FY12 | FY26 | ||||||
| Northeast | Griffiss | SS054 | Bldg 781, Pumphouse - Free Product on Groundwater (NYSDEC Spill #9202658) | N/A | NYSDEC R6 Corrective Action (Spills) Program | RA-O | O&M of biosparging system, quarterly GW monitoring, LUC/IC Monitoring, Non-CERCLA Five-Year Review (AF Policy Review) | 1 - Biosparging System | Biweekly O&M (system inactive) |
Quarterly Sampling Annual Report Annual Inspections
| FYR every five years | Petroleum only site, injections completed in 2017. Preliminary observations from 2018 evaluation of existing biosparging system indicates that system modification or installation of new sparge wells may be required. | RA-O | FY26 | FY26 | ||||||
| Northeast | Griffiss | SS062 | AOC 9 Weapons Storage Area Landfill Chlorinated Plume | N/A | CERCLA | RA-O | GW monitoring, LUC/IC monitoring and Five-Year Review | None | Annual Sampling/Report |
Annual Inspections
| FYR every five years | -Injections completed in 2017 and 2018; SVI restriction remains on the site. -PFOS/PFOA detected within the site boundaries. Investigation and remediation of PFAS is not included in this TO. | RA-O | FY26 | Indefinite | |||||
| Northeast | Griffiss | SS067 | Building 789 Type II Fuel System (NYSDEC Spill #9810713) | N/A | NYSDEC R6 Corrective Action (Spills) Program | RA-O | O&M of biosparge and free product recovery systems, Product Guaging and Manual Recovery, GW monitoring, and LUC/IC monitoring, Non-CERCLA Five-Year Review (AF Policy Review) | 1 - Biosparging System |
1 - Free Product Recovery System Quarterly gw Sampling Annual Report Annual Inspections FYR every five years
| FPRS System remains off (quarterly recovery), air sparge system is on off and on standby (requires annual inspection) | Results of data gap analysis conducted in late 2018 and product guaging expected early 2020. | RA-O | FY26 | FY26 | ||||||
| Northeast | Griffiss | LF001 | Landfill 1 | N/A | CERCLA | LTM | Engineered RCRA Cap. Landfill LTM (inspection, maintenance, landfill gas and groundwater, surface water monitoring), LUC/IC monitoring, and Five-Year Review | None | Semiannual Inspec./report |
Annual gas sampling Biennial gw/sw sampling/report
| FYR every five years | PFOS/PFOA detected within the site boundaries. Investigation and remediation of PFAS is not included in this TO. | LTM | FY04 | Indefinite | ||||||
| Northeast | Griffiss | LF002 | Landfill 2 & 3 | N/A | CERCLA | LTM | Engineered RCRA Cap. Landfill LTM (inspection, maintenance, landfill gas and ground/surface water monitoring), LUC/IC monitoring, and Five-Year Review | None | Semiannual Inspect./report |
Annual gas sampling GW/sw sampling every 5 years/report FYR every five years
| LTM | FY03 | Indefinite | |||||||
| Northeast | Griffiss | LF003 | Landfill 7 | N/A | CERCLA | LTM | Soil/Veg Cap. Landfill LTM (inspection, maintenance, and ground/surface water monitoring), LUC/IC monitoring, and Five-Year Review | None | Semiannual Inspect./report |
GW/sw sampling every 5 years/report
| FYR every five years | LTM | FY03 | Indefinite | |||||||
| Northeast | Griffiss | LF007 | Landfill 5 | N/A | CERCLA | LTM | Soil/Veg Cap. Landfill LTM (inspection, maintenance, and ground/surface water monitoring), LUC/IC monitoring, and Five-Year Review | None | Semiannual Inspect./report | |
| GW/sw sampling every 5 years/report | LTM | FY05 | Indefinite | |||||||
| Northeast | Griffiss | LF009 | Landfill 6 | N/A | CERCLA | LTM | Engineered Cap. Landfill LTM (inspection, maintenance, LF gas and ground/surface water and leachate monitoring), LUC/IC monitoring, and Five-Year Review | None | Semiannual Inspect./report |
Annual gas sampling SW/leachate sampling every 5 years/report
| PFOS/PFOA detected within the site boundaries. Investigation and remediation of PFAS is not included in this TO. | LTM | FY01 | Indefinite | |||||||
| Northeast | Griffiss | SS008 | Bldg 112/PCB Dump Area | South Side-PCB Trans Leak, Roof (Former SS-19) | CERCLA | LTM | LUC/IC monitoring and Five-Year Review | None | Annual Inspections | |
| FYR every five years | LTM | FY05 | Indefinite | |||||||
| Northeast | Griffiss | SS017 | Lot 69 Former Hazardous Waste Storage Area | N/A | CERCLA | LTM | LUC/IC monitoring and Five-Year Review | None | Annual Inspections | |
| FYR every five years | Groundwater restriction deletion approved in 2013. Site closure (SC) under current PBR TO is pending. | LTM | FY01 | Indefinite | ||||||
| Northeast | Griffiss | SS025 | T-9 Storage Area - contaminated soil/groundwater | N/A | CERCLA | LTM | LUC/IC monitoring and Five-Year Review | None | Annual Inspections | |
| FYR every five years | Groundwater restriction deletion approved in 2013. Site closure (SC) under current PBR TO is pending. | LTM | FY05 | Indefinite | ||||||
| Northeast | Griffiss | DP022 | Bldg 222 | N/A | CERCLA | LTM | Explanation of Significant Difference (ESD) to document change in site boundary; LUC/IC monitoring and Five-Year Review | None | Annual Inspections | |
| FYR every five years | -Groundwater restriction deletion approved in 2013. -Contamination discovered just outside the boundary of the site in 2017; current use will not accommodate removal; ESD will adjust site boundary to encompass footprint of the bldg. | LTM | FY01 | Indefinite | ||||||
| Northeast | Griffiss | SS033 | Coal Storage Area - PCB Contamination | N/A | CERCLA | LTM | LUC/IC monitoring and Five-Year Review | None | Annual Inspections | |
| FYR every five years | Includes evaluation of AOI 66 in Five-Year Review with LUC/IC monitoring and FYR | LTM | FY01 | Indefinite | ||||||
| Northeast | Griffiss | SS044 | Substation, Electrical Power - PCB Site | N/A | CERCLA | LTM | LUC/IC monitoring and Five-Year Review | None | Annual Inspections | |
| FYR every five years | LTM | FY12 | Indefinite | |||||||
| Northeast | Griffiss | SD052 SVI | -1 | Apron 2 Chlorinated Plume Site (Bldg 785 & 786) sub-slab vapor mitigation | CERCLA | LTM | O&M of passive sub-slab vapor mitigation system, monitoring, reporting, LUC/IC monitoring and Five-Year Review | 1 - Vapor Mitigation System on standby, passive system in place | Twice Annual indoor/outdoor air and subslab vapor sampling (heating season) |
Annual Report Annual Inspections
| FYR every five years | -Active mitigation system (projected conversion to passive 2018-2019) to be kept in stand-by mode -SVI cannot reach SC prior to completion of GW cleanup objective. | LTM | FY05 | Indefinite | |||||||||||
| Northeast | Griffiss | SS060 | STW-1300 Bldg 35/36 AOC | N/A | RCRA | LTM | LUC/IC monitoring and Non-CERCLA Five-Year Review (AF Policy Review) | None | Annual Inspections | ||||||
| FYR every five years | LTM | FY00 | Indefinite | ||||||||||||
| Northeast | Loring | SD010 | Flightline Drainage Ditch | FLDD EBGB | 13 | CERCLA | RA-O | OU13-Basewide surface water drainage, monitor concentrations of polychlorinated biphenyls (PCBs) and pesticides in fish tissue, stream sediment, and other biota every five years (2023, 2028). LUC inspections and Five-Year Reviews. | None | Annual LUC inspections, fish sampling every five years | PCB impoundments were constructed along the East Branch of Greenlaw Brook. Inspection conducted in 2018 indicated erosion risk. Design and implementation of additional remedial action is not included in this TO. | LTM | FY98 | Indefinite | |
| Northeast | Loring | SS054 | GMZ #1 Industrial Area | GMZ-1 | 12 | CERCLA | RA-O | Groundwater monitoring and biennial surface water monitoring, LUC inspections and Five-Year Reviews | None | Annual | ES/JEBS Plume has a TI waiver that requires a technology evaluation every five years in conjunction with the Five-Year Review | RA-O | FY30 | Indefinite | |
| Northeast | Loring | SS056 | GMZ # 3 BX Service Station | GMZ-3 | 12 | CERCLA | RA-O | Groundwater and surface water monitoring, LUC inspections, and Five-Year Reviews. | None | Annual | Recently discovered soil contamination that may require delineation and other remedial actions like bioremediation and addn’l gw monitoring not included in this TO. | RA-O | FY30 | FY30 | |
| Northeast | Loring | SS057 | GMZ # 4 Quarry | GMZ-4 | 12 | CERCLA | RA-O | Groundwater and surface water monitoring, performance monitoring of in-situ enhanced bioremediation, LUC inspections and Five-Year Reviews. | None | Annual | Pilot study completed in November 2017 indicated potential for mass reduction via continued injections/ recirculation but the extent of the contamination is a factor. Modification of remedy based on pilot study is included in this TO. -TI waiver requires technology evaluation every five years in conjunction with the Five-Year Review. | RA-O | Indefinite | Indefinite | |
| Northeast | Loring | SS058 | GMZ # 5 F Jet | GMZ-5 FJETC | 12 | CERCLA | RA-O | Groundwater monitoring, LUC inspections and Five-Year Reviews. | None | Annual | SC | FY25 | FY25 | ||
| Northeast | Loring | SS059 | GMZ # 6 East Base | GMZ-6 | 12 | CERCLA | RA-O | Groundwater and surface water monitoring, LUC inspections and Five-Year Reviews. | None | Annual | Elevated manganese in the groundwater; site is located in remote part of base on U.S. Fish and Wildlife Service property. Development of recommendations to address manganese is included in this TO; however, implementation is not included. | RA-O | TBD | Indefinite | |
| Northeast | Loring | SS062 | Littleton Pump Station (Searsport Pipeline) | POL | RA-O | Groundwater monitoring, LUC inspections and Five-Year Reviews | None | Annual | Petroleum plume has migrated onto private property. | RC | FY29 24 | FY29 | |||
| Northeast | Loring | SS063 | Mattawamkeag Pump Station (Searsport Pipeline) | POL | RA-O | Semiannual (Spring and Fall) groundwater monitoring, LUC inspections and Five-Year Reviews | None | Annual | Investigation and remediation of LNAPL in the shallow bedrock is not included in this TO. | RA-O | FY30 | FY30 | |||
| Northeast | Loring | CLF004 | ASB LF Asbestos Landfill | Asbestos Landfill | MEDEP | LTM | Annual cap inspections, mowing, and erosion control as required. LUC inspections. No Five-Year Review required. | None | Annual | Inspection included in annual landfill monitoring report | LTM | FY99 | Indefinite | ||
| Northeast | Loring | LF001 | Landfill 1 | MEDEP | LTM | LUC inspections. No Five-Year Review required. | None | Annual | LUC inspections only | LTM | FY12 | Indefinite | |||
| Northeast | Loring | LF002 | Landfill 2 | CERCLA | LTM | Unlined RCRA cap with impermeable cover. Annual cap inspections, mowing, erosion control as required; triennial landfill gas monitoring and groundwater elevation monitoring, and groundwater monitoring to support five-year reviews. LUC inspections and Five-Year Reviews. | None | Annual | Monitoring period is 30 years, until 2026 | LTM | FY96 | Indefinite | |||
| Northeast | Loring | LF020 | Landfill #3 | Landfill 3 | CERCLA | LTM | Annual cap inspections, mowing, erosion control as required; triennial landfill gas monitoring and groundwater elevation monitoring, and groundwater monitoring to support five-year reviews. LUC inspections and Five-Year Reviews. | None | Annual | Monitoring period is 30 years, until 2029 | LTM | FY99 | Indefinite | ||
| Northeast | Loring | OT018 | Fly Ash Disposal Site | FADS | MEDEP | RA-O | Annual cap inspections, mowing, erosion control as required, LUC inspections. No Five-Year Review required. | None | Annual | Inspection included in annual landfill monitoring report | RA-O | FY96 | Indefinite | ||
| Northeast | Loring | CCG006 | N. Wherry URZ North Wherry Groundwater Use Restriction Zone | North Wherry GURZ | POL | LTM | LUC Inspections, AF Policy five-year review required. | None | Annual LUC inspection, sample every five years | GW sampling every five years (2020, 2025) to determine if closure objectives have been achieved and LUCs can be released. | LTM | FY00 | FY31 | ||
| Northeast | Loring | CCG007 | S. Wherry URZ South Wherry Groundwater Use Restriction Zone | South Wherry GURZ | POL | LTM | LUC Inspections, AF Policy five-year review required. | None | Annual LUC inspection, sample every five years | GW sampling every five years (2020, 2025) to determine if closure objectives have been achieved and LUCs can be released. | LTM | FY00 | FY31 | ||
| Northeast | Loring | CCG008 | Nose Dock URZ Nose Dock Groundwater Use Restriction Zone | Nose Dock GURZ | POL | LTM | LUC Inspections, AF Policy five-year review required. | None | Annual LUC inspection, sample every five years | GW sampling every five years (2020, 2025) to determine if closure objectives have been achieved and LUCs can be released. | LTM | FY00 | FY31 | ||
| Northeast | Loring | CCG009 | S. Flightline URZ South Flightline Groundwater Use Restriction Zone | South Flightline GURZ | POL | LTM | LUC Inspections, AF Policy five-year review required. | None | Annual LUC inspection, sample every five years | GW sampling every five years (2020, 2025) to determine if closure objectives have been achieved and LUCs can be released. | LTM | FY00 | FY31 | ||
| Northeast | Loring | CCG010 | Alert Area URZ Alert Area Groundwater Use Restriction Zone | Alert Area GURZ | POL | LTM | LUC Inspections, AF Policy five-year review required. | None | Annual LUC inspection, sample every five years | GW sampling every five years (2020, 2025) to determine if closure objectives have been achieved and LUCs can be released. | LTM | FY00 | FY31 | ||
| Northeast | Loring | CCG011 | DRMO URZ DRMO Groundwater Use Restriction Zone | DRMO GURZ | POL | LTM | LUC Inspections, AF Policy five-year review required. | None | Annual LUC inspection, sampler every five years | GW sampling every five years (2020, 2025) to determine if closure objectives have been achieved and LUCs can be released. | LTM | FY00 | FY31 | ||
| Northeast | Loring | CCG012 | East Base URZ East Base Groundwater Use Restriction Zone | East Base GURZ | POL | LTM | LUC Inspections, AF Policy five-year review required. | None | Annual LUC inspection, sample every five years | GW sampling every five years (2020, 2025) to determine if closure objectives have been achieved and LUCs can be released. | LTM | FY00 | FY31 | ||
| Northeast | Loring | CCF001 | Building 6100 URZ BLDG 6100 Use Restriction Zone | Building 6100 URZ | MEDEP | LTM | LUC Inspections, AF Policy five-year review required. | None | Annual LUC inspection | GW sampling every five years (2020, 2025) to determine if closure objectives have been achieved and LUCs can be released. | LTM | FY93 | Indefinite | ||
| Northeast | Loring | CCF002 | Building 6200 URZ GLDG 6200 Use Restriction Zone | Building 6200 URZ | MEDEP | LTM | LUC Inspections, AF Policy five-year review required. | None | Annual LUC inspection | LTM | FY93 | Indefinite | |||
| Northeast | Loring | CCF003 | Building 6700 URZ GLDG 6200 Use Restriction Zone | Building 6700 URZ | MEDEP | LTM | LUC Inspections, AF Policy five-year review required. | None | Annual LUC inspection | LTM | FY90 | Indefinite | |||
| Northeast | Pease | SS013 | Bulk Fuel Storage Area (BFSA) | NHDES | RA-O | Groundwater monitoring, LUCs and Five-Year Review | None | Annual | PFOS/PFOA detected within the site boundaries. Investigation and remediation of PFAS is not included in this TO | RA-O | FY30 | FY30 | |||
| Northeast | Pease | ST081 | Self-Help Shop | NHDES | RA-O | Groundwater monitoring and rebound monitoring, LUCs and Five-Year Review | None | Annual | May achieve RC prior to end of 2020 | RA-O | FY23 | FY23 | |||
| Northeast | Pease | SS082 | Plume 13/14 | NHDES | RA-O | Groundwater monitoring, LUCs and Five-Year Review | None | Biennial | -Air sparge/soil vapor extraction system inactive due to assumed methane accumulation. Evaluation of methane not included in this TO. -Potential impacts associated with PFOS/PFOA P&T system (AIMS) exist. PFOS/PFOA detected within the site boundaries Investigation and remediation of PFAS is not included in this TO | RA-O | FY25 | FY25 | |||
| Northeast | Pease | SS083 | Plume 41 | NHDES | RA-O | Groundwater monitoring, LUCs and Five-Year Review | None | Annual | Potential impacts associated with PFOS/PFOA P&T system (AIMS) exist. PFOS/PFOA detected within the site boundaries | ||||||
| Investigation and remediation of PFAS is not included in this TO | RA-O | FY25 | FY25 | ||||||||||||
| Northeast | Pease | SS084 | Pumphouse 2 | NHDES | RA-O | Groundwater monitoring, LUCs and Five-Year Review | None | Biennial | -Air sparge/soil vapor extraction system inactive due to assumed methane accumulation. Evaluation of methane not included in this TO. -Potential impacts associated with PFOS/PFOA P&T system (AIMS) exist. PFOS/PFOA detected within the site boundaries | ||||||
| Investigation and remediation of PFAS is not included in this TO | RA-O | FY27 | FY27 | ||||||||||||
| Northeast | Pease | TU032 | Building 113 | CERCLA | RA-O | RA-O of isolation unit (sheet pile), performance monitoring, groundwater monitoring, LUCs and Five-Year Review | None | Biennial | Performance monitoring of new ISEB injections may be required | RA-O | FY20 | Indefinite | |||
| Northeast | Pease | ID039 | Building 227 | CERCLA | RA-O | SVE; performance monitoring of ISEB; and groundwater monitoring, LUCs and Five-Year Review | 1 - SVE System | Biennial | Vapor intrusion pathway issue, PRAP/ROD amendment in progress to document SVE installation and will be completed by current contractor. Performance monitoring/system balancing may be required. Additional indoor air patrhway analysis may be needed if building occupied | RA-O | FY23 | Indefinite | |||
| Northeast | Pease | AB022 | Burn Area 1 | CERCLA | RA-O | Groundwater monitoring, decommissioning of AS/SVE, LUCs and Five-Year Review | 1 - Air Sparge/SVE System (No Longer Required) | Biennial | LNAPL discovered along with groundwater divide may drive alternate approach; metals issues. Evaluation of additional remedy not included in this TO | RA-O | FY27 | FY27 | |||
| Northeast | Pease | SS036 | Building 119 | CERCLA | RA-O | Groundwater monitoring, LUCs and Five-Year Review | None | Semiannual | PFOS/PFOA detected within the site boundaries Investigation and remediation of PFAS is not included in this TO. | RA-O | FY30 | FY30 | |||
| Northeast | Pease | SS049 | Building 22 | CERCLA | RA-O | MNA with PRB monitoring; performance monitoring of ISEB, groundwater monitoring, LUCs and Five-Year Review | None | Annual | Potential upgradient source (DNAPL in fractured bedrock), four new wells installed to delineate and possibly treat hot-spot in 2019. Evaluation of additional remedy for potential upgradient source not included in this TO, however performance monitoring continuation will be required | RA-O | FY48 | FY48 | |||
| Northeast | Pease | ID073 | Building 234 | CERCLA | RA-O | Groundwater monitoring, LUCs and Five-Year Review | None | Annual | -Established remedy creating reducing conditions that mobilize arsenic. Evaluation of additional remedy not included in this TO. -PFOS/PFOA detected within the site boundaries. Investigation and remediation of PFAS is not included in this TO. | RA-O | FY23 | FY23 | |||
| Northeast | Pease | DP010 | Leaded Fuel Tank Sludge Area | CERCLA | RA-O | Groundwater monitoring, LUCs and Five-Year Review | None | Biennial | Benzene rebound attributed to unknown source. Evaluation of additional remedy not included in this TO. | RA-O | FY27 | FY27 | |||
| Northeast | Pease | LF006 | Landfill 6 | CERCLA | LTM | Annual inspections, triennial groundwater monitoring, and Five-Year Review | None | Triennial | Issues with arsenic due to reducing conditions post LF removal, potentially caused by wetland, geochemical analysis conducted in 2018 to determine if Arsenic issue is not naturally occurring. Evaluation of additional remedy not included in this TO. | LTM | FY07 | FY28 | |||
| Northeast | Pease | SS045 | Old Engine Test Stands (OJETS) | CERCLA | RA-O | Groundwater monitoring, LUCs and Five-Year Review | None | Annual | Manganese remains elevated after completion of remedy and residual reducing conditions difficult to overcome. Evaluation of additional remediation not included in this TO | RA-O | FY27 | FY27 | |||
| Northeast | Pease | ST072 | Motor Pool | NHDES | RA-O | Groundwater monitoring, LUCs and Five-Year Review | None | Annual | Site will attain RC for POL contaminants, however reducing conditions remain and arsenic has not achieved cleanup level. New groundwater management zone to be established by current contractor | RA-O | FY30 | FY30 | |||
| Northeast | Pease | SS016 | Building 410 | CERCLA | LTM | Confirmation sampling to validate contamination has been removed, remove LUC/ICs if UU/UE, LUCs and Five-Year Review | None | Annual | PCB release; acceptable for commeercial/industrial use; sampling could result in UU/UE and SC | LTM | FY95 | FY28 | |||
| Northeast | Pease | DP009 | Construction Rubble Dump 1 (CRD-1) | NHDES | LTM | Annual cap inspections, settlement monitoring every 5 yrs, mowing as needed, and erosion control, LUCs and Five-Year Review | None | Annual | LTM | FY95 | Indefinite | ||||
| Northeast | Pease | DP017 | CRD-2 | NHDES | LTM | Annual cap inspections, annual mowing, erosion control, and surface water and sediment sampling, LUCs and Five-Year Review | None | Annual | LTM | FY95 | Indefinite | ||||
| Northeast | Pease | ST085 | Flightline Refueling System (FLRS) | NHDES | RA-O | Groundwater monitoring, LUCs and Five-Year Review | None | Annual | MNA not meeting goals. Evaluation of additional remedy not included in this TO. | RA-O | FY30 | Indefinite | |||
| Northeast | Pease | LF005 | Landfill 5 | CERCLA | LTM | Annual cap inspections, settlement monitoring every 5-yrs, annual mowing, erosion control, triennially groundwater monitoring, surface water and sediment sampling, LUCs and Five-Year Review | None | Annual inspections, Triennial GW | LTM | FY08 | Indefinite | ||||
| Northeast | Pease | LF001 | Landfill 1 | NHDES | LTM | Annual cap inspections, mowing as needed, erosion control, triennial groundwater monitoring, surface water and sediment sampling , LUCs and Five-Year Review | None | Annual inspections, Triennial GW | LTM | FY96 | Indefinite | ||||
| Northeast | Pease | Not Applicable | Zone 2 | CERCLA | LTM | Groundwater monitoring, LUCs and Five-Year Review | None | Biennial | Includes former AB037 monitoring requirements; closure of Zone 2 is dependent on closure of individual sites in Zone 2. | LTM | TBD | Indefinite | |||
| Northeast | Pease | OU11 | Brooks and Ditches | CERCLA | LTM | Surface water and sediment monitoring, LUCs and Five-Year Review | None | None | LTM | TBD | TBD | ||||
| Northeast | Plattsburgh | FT002/Industrial Area Ground-water OU | Basewide Groundwater (Includes Fire Training Area and Industrial Area GW) | N/A | CERCLA | RA-O | a) Groundwater monitoring, discharge sampling, LUC/IC monitoring, and Five-Year Review |
b) Operation of SVE system (VGAC) at Bldg. 2753 (installed late FY09, deactivated in Feb 2014 and reactivated in Feb 2018) w/ deactivation pending regular review of operational condition/sampling results, and annual sub-slab and indoor air sampling.
c) Annual sub-slab and indoor air sampling at New Building C and Bldg. 2766, SVE systems at these two locations have been deactivated and confirmation sampling is in progress ( may require reactivation if rebound occurs). d) Quarterly monitoring and inspections and maintenance including whole house filter changeout, carbon recycling and replacement/changeout on whole home PFOS/PFOA mitigation systems at one location
e) Discharge monitoring and reporting associated with groundwater collection trenches
f) O&M of three passive groundwater collection trenches including cleaning of 10,900 feet of trench and 1,550 ft of discharge piping
g) Ongoing O&M of Aeration pond
3 - Vapor Mitigation Systems (1 Active (B2753); 2 Standby)
1 - Home GAC System
3 - Passive Collection Trenches
1 - Aeration system Every 5th Qtr gw sampling/report Annual Inspections FYR every five years; regular O&M of the aeration pond
B2753: Biweekly O&M Annual indoor air and subslab vapor sampling/report combined w/ other Bldgs
B2766: Annual indoor air and subslab vapor sampling/report combined w/ other Bldgs
New Bldg C: Annual indoor air and subslab vapor sampling/report combined w/ other Bldgs
Quarterly PFOS/PFOA system monitoring/ inspection/maintenance with reporting/notification
Quarterly Outfall discharge sampling/data release with annual water qual & parameters -Runway/Flightline Collection Trench (RFCT) GW Treatment Plant has been deactivated and approved for decommissioning/demolition which is included in this TO. -PFOS/PFOA detected within the site boundaries. Investigation and remediation of PFAS is not included in this TO.
PFOS/PFOA impacts
| Whole home system at Res04 is associated with site FT002 | RA-O | FY84 | FY84 | |||||||
| Northeast | Plattsburgh | FT002 | PFAS Site | |||||||
| Northeast | Plattsburgh | SS013 | Munitions Maintenance Squadron | N/A | CERCLA | RA-O | Ozone sparging system operated intermittently through 2014; Soil excavation to remove residual contamination planned in 2018 followed by possible restart of ozone sparge system; groundwater/surface water monitoring, LUC/IC monitoring including general SVI restriction and occupancy restriction for Bldg. 3578, and Five-Year Review. | 1 - Ozone Sparging System inactive | Quarterly gw/sw monitoring/report |
Annual Inspections
| FYR every five years | -The SVI restriction is based on calculations and not an actual study. Site closure (SC) under current PBR TO is pending. -PFOS/PFOA detected within The Site boundaries Investigation and remediation of PFOS/PFOA is not included in this TO. | SC | for GW FY26 | |||||||
| Northeast | Plattsburgh | RW042 | Wash Rack AOC | N/A | non-CERCLA managed as petroleum site | RA-O | Semiannual groundwater monitoring, LUC/IC monitoring and Non-CERCLA Five-Year Review (AF Policy Review). | None | Semiannual gw sampling/report |
Annual Inspections
| FYR every five years | -LNAPL discovered at site in 2017; results of investigation under current PBR are expected Jun 2021. Modification to the remedy based on the investigation is not included in this TO. -PFOS/PFOA detected within the site boundaries. Investigation and remediation of PFOS/PFOA is not included in this TO. | RA-O | TBD | |||||||
| Northeast | Plattsburgh | CTU234 | UST-3580 | Former heating fuel UST | NYSDEC R5 Corrective Action (Spills) Program | RA-O | MNA, Groundwater monitoring, LUC/IC inspections and Non-CERCLA Five-Year Review (AF Policy Review) | None | Quarterly gw sampling |
Annual report Annual Inspections
| FYR every five years | Site closure (SC) is pending on the current PBR TO. | SC | FY12 | FY25 | ||||||
| Northeast | Plattsburgh | CTU281 | UST-2704 | Former diesel fuel UST | NYSDEC R5 Corrective Action (Spills) Program | RA-O | LUC/IC Monitoring and Non-CERCLA Five-Year Review (AF Policy Review) | None | Annual Inspections | |
| FYR every five years | Injection completed in 2018. Site closure (SC) is pending on the current PBR TO, but there may be external issues impacting site (i.e. abandoned underground fuel pipeline, and two adjacent fuels sites that were closed out pre base closure ~ 1991) | LTM | FY31 | Indefinite | ||||||
| Northeast | Plattsburgh | CTU-294 | UST-2009 | Former fuel oil UST | NYSDEC R5 Corrective Action (Spills) Program | RA-O | Groundwater monitoring, LUC/IC inspections, and Non-CERCLA Five-Year Review (AF Policy Review) | None | Quarterly GW/soil performance sampling |
Annual report Annual Inspections
| FYR every five years | Soil excavation and mixing completed in 2017. Site closure (SC) is pending on the current PBR TO. | RA-O | FY28 | FY28 | ||||||
| Northeast | Plattsburgh | SS005 | No-Destructive Inspection (NDI) Facility | N/A | CERCLA | LTM | LUC/IC monitoring (Groundwater, Non Residential Use) and Five-Year Review | None | Annual Inspections | |
| FYR every five years | LTM | FY98 | Indefinite | |||||||
| Northeast | Plattsburgh | SS006 | Aerospace Ground Equipment (AGE) Facility | N/A | CERCLA | LTM | LUC/IC monitoring (Groundwater, Non Residential Use) and Five-Year Review | None | Annual Inspections | |
| FYR every five years | LTM | FY98 | Indefinite | |||||||
| Northeast | Plattsburgh | SS018 | Auto Hobby Shop | N/A | CERCLA | LTM | LUC/IC monitoring (non-residential use), and Five-Year Review | None | Annual Inspections | |
| FYR every five years | LTM | FY13 | Indefinite | |||||||
| Northeast | Plattsburgh | LF021 | Former Landfill (56-59) | N/A | CERCLA | LTM | Soil/vegetative cover. Landfill LTM (inspection, maintenance, and groundwater monitoring), LUC/IC monitoring, and Five-Year Review | None | Annual Inspect./report |
Biennial gw sampling/report GW sampling every 5 years/report
| FYR every five years | LTM | FY97 | Indefinite | |||||||
| Northeast | Plattsburgh | LF022 | Former Landfill (59-66) | (D-3, D-7) | CERCLA | LTM | Soil/vegetative cover. Landfill LTM (inspection, maintenance, and groundwater monitoring), LUC/IC monitoring, and Five-Year Review | None | Annual Inspect./report |
Biennial gw sampling/report GW sampling every 5 years/report
| FYR every five years | LTM | FY95 | Indefinite | |||||||
| Northeast | Plattsburgh | LF023 | Former Landfill (66-81) | (D-4) | CERCLA | LTM | Engineered RCRA Cap. Landfill LTM (inspection, maintenance, landfill gas monitoring, and groundwater monitoring including baseline and routine events LUC/IC monitoring, and Five-Year Review. | None | Annual Inspect./report |
Annual gas sampling Annual routine gw sampling/report Every 5 years baseline gw sampling/report GW/sw sampling every 5 years/report
| FYR every five years | Site is governed by a Source Control Record of Decision and a Groundwater Operable Unit Record of Decision | LTM | FY95 | Indefinite | ||||||
| Northeast | Plattsburgh | LF024 | Former C & D Landfill | N/A | CERCLA | LTM | Soil/vegetative cover. Landfill LTM (inspection, maintenance, and groundwater monitoring), LUC/IC monitoring, and Five-Year Review | None | Annual Inspect./report |
Biennial gw sampling/report GW sampling every 5 years/report
| FYR every five years | LTM | FY97 | Indefinite | |||||||
| Northeast | Plattsburgh | SS028 | Building 508 Open Storage Area | N/A | CERCLA | LTM | LUC/IC (non-residential use) monitoring and Five-Year Review | None | Annual Inspections | |
| FYR every five years | Soil investigation/excavation planned. SVI issues may require additional LUC/ICs at the site. Site closure (SC) under current PBR is pending. | LTM | FY21 | Indefinite | ||||||
| Northeast | Plattsburgh | SS031 | Central Heat Plant | N/A | NYSDEC R5 Corrective Action (Spills) Program | LTM | LUC/IC Monitoring and Non-CERCLA Five-Year Review (AF Policy Review) | None | Annual Inspections | |
| FYR every five years | Petroleum only site; Site closure (SC) under current PBR TO is pending w/ contamination discovered at site boundary near rails; if SC is not achieved, LUC/ICs including SVI restriction may be required. | LTM | FY21 | Indefinite | ||||||
| Northeast | Plattsburgh | CWM127 | OTH-3505-1 | Construction Debris Area | RCRA | LTM | LUC/IC Inspections and Five-Year Review | None | Annual Inspections | |
| FYR every five years | Decision document being prepared under current PBR TO projected for completion by 2021 to memorialize establishment of LUC/ICs | LTM | FY21 | Indefinite | ||||||
| Northeast | Plattsburgh | CSA283 | OTH-3210-2 | D&H Nursery | RCRA | LTM | LUC/IC Inspections and Five-Year Review | None | Annual Inspections | |
| FYR every five years | Decision document being prepared under current PBR TO projected for completion by 2021 to memorialize establishment of LUC/ICs | LTM | FY21 | Indefinite | ||||||
| Northeast | Plattsburgh | CDA286 | OTH-1700 | Area R Trash Dump | RCRA | LTM | LUC/IC Inspections and Five-Year Review | None | Annual Inspections | |
| FYR every five years | Decision document being prepared under current PBR TO projected for completion by 2021 to memorialize establishment of LUC/ICs | LTM | FY21 | Indefinite |
FA8903-20-R-0011
Attachment 1 Northeast Region 5 December 2019
&P of &N
File details come from the government source that posted it. Updated .