SXHT 16-1028 Atch2 Drawings.pdf
PDF 11 MB Posted
- Attached to
- REPAIR, RENOVATE PMEL
- Solicitation number
- FA252126B0001
About this file
Summary
This is a set of construction design documents (Contract No. FA2521-24-D0002) for the Repair, Renovate PMEL Building 981 at Patrick Space Force Base in Florida. The project involves comprehensive renovation of mechanical, electrical, structural, fire alarm, and architectural systems within an existing Precision Measurement Equipment Laboratory (PMEL) facility. The contract is issued by the USSF 45th Civil Engineer Squadron with a 100% submittal dated July 9, 2025.
The mechanical work includes demolition and replacement of twelve air handling units (AHU-01 through AHU-12 plus OAU-01), new ductwork, piping systems, and building automation controls integrated with a BACnet IP system. Electrical work encompasses new power distribution, variable frequency drives (VFDs) for motor control, disconnect switches, and receptacles for the HVAC equipment, with power sourced from existing 480V/208Y120V panels (2DP-2, 2DP-3, 2DP-4, P-3, P-7). Structural repairs include concrete housekeeping pad construction for equipment and CMU wall crack repair. Fire alarm system replacement includes thirty manual pull stations, thirty smoke detectors, fifteen strobes, and integration with a campus-wide mass notification system. All work must comply with G10 SLD45 IFS HVAC Standards, 2023 NEC, UFC standards, and local Florida building codes. The project requires extensive coordination between trades, field verification of existing conditions, testing and balancing of HVAC systems, and compliance with hazardous materials protocols and environmental permitting requirements.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B A
N A
N A
R
IV
E R
B A
N A
N A
R
IV
E R
A T
L A
N T
IC
O
C E
A N
S T
A T
E R
O A
D A
A
S O
U T
H P
A T
R
IC
K D
R
IV
E
B
IK
E P
A T
H
S L
A B
S
S L
A B
S
S L
A B
S
A N
T E
N N
A
W A
LL
P
IC
N
IC
S H
E L
T E
R S
A N
T E
N N
A
G E
N E
R A
T O
R
WALL
WALL
F
IL
T R
A T
IO
N
P L
A N
T
S E
W A
G E
T R
E A
T M
E N
T
P L
A N
T
BINS
BINS
S H
E D
WALL WALL WALL
WALL
T A
N K
WALL
S L
A B
S
S L
A B
S
W A
L L
WALL
B
IKE
P A
TH
BIKE PATH
P E
D
ES
T
RIA
N U
N D
E
RP
A S
S
B
IKE
P A
TH
BIKE PATH
P E
D
ES
T
RIA
N U
N D
E
RP
A S
S
S T
A T E
R O
A D
A
A
S T
A T E
R O
A D
A
A
S T
A T E
R O
A D
A
A
WEST BOUND
EAST BOUND
PINEDA EXPRESSWAY
STATE ROAD 404
PINEDA EXPRESSWAY WEST BOUND
STATE ROAD 404 EAST BOUND
PINEDA EXPRESSWAY WEST BOUND
STATE ROAD 404 EAST BOUND
PINEDA EXPRESSWAY WEST BOUND
STATE ROAD 404 EAST BOUND
6TH HOLE SUNSET BLVD
CONTROL ROAD
CONTROL ROAD
C O
N T
R O
L R O
A D
CONTROL ROAD
C O
N T
R O
L R
O A
D
S O
U T
H P
A T
R
IC
K D
R
IV
E
PINEDA EXPRESSWAY
STATE ROAD 404 EASTBOUND
WESTBOUNDPINEDA EXPRESSWAY WESTBOUND
STATE ROAD 404 EASTBOUND
S O
U T H
P A
T R
IC
K D
R
IV
E
MARINA ROAD
S O
U T
H P
A T
R
IC
K D
R
IV
E
MARINA ROAD
MARINA ROAD
B
IK
E P
A T
H
S O
U T
H P
A T
R
IC
K D
R
IV
E
MACE ROAD
MACE ROAD
CUMULUS LANE
B
LU
E
SKY
LANE
MISTY LANE
FOGGY LANE
THUNDER LAN E
BREAKERS
LANE
BREAKERS LANE
S T
O R
M Y
L A
N E
SCHOOL AVE
SC
HO
O
L AVE
S C
R
U B
JAY
R UN
PANTHER RUN
H A
B
IT
A T
R U
N
COUGAR RUN
H A
B
IT
A T
R U
N
ALLIGATOR
RUN
DUSKY RUN
COYOTE
RUN
JAGUAR RUN
BEAR
RUN
RUN
P A
R R O
T
F O
R E
C A
S T
L A
N E
F O
R E C
A S T L
A N
E
F O
R E
C A
S T
L A
N E
NEW MACE ROAD
NEW
MACE ROAD
G R
EE
N
T E
E
G R
EE
N
S A
N D
T R
A P
T E
E
T E
E
T E
E
G R
EE
N
T E
E
S O
D
G R
EE
N
T E
E
T E
E
T E
E
G R
EE
N
G R
EE
N
T E
E
T E
E
T E
E
G R
EE
N
G R
EE
N
T E
E
T E
E
T E
E
T E
E
T E
E
T E
E
S A
N D
T R
A P
G R
EE
N
T E
E
T E
E
G R
EE
N
T E
E
T E
E
G R
EE
N
T E
E
T E
E
T E
E
T E
E
T E
E
T E
E
T E
E
T E
E
T E
E
T E
E
T E
E
G R
EE
N
T E
E
T E
E
T E
E
D R
IVIN
G
R
AN
G E
G R
EE
N
T E
E
G R
EE
N
T E
E
T E
E
T E
E
G R
EE
N
Y
D
G R
EE
N
T E
E
T E
E
T E
E
T E
E
T E
E
T R
A P
T R
A P
G R
EE
N
S A
N D
T R
A P
S A
N D
T R
A P
S A
N D
T R
A P
S A
N D
T R
A P
S A
N D
T R
A P
S A
N D
T R
A P
S A
N D
T R
A P
Y
D
M A
R K
Y
D
M A
R K
Y
D
M A
R K
S A
N D
T R
A P
S A
N D
T R
A P
S A
N D
T R
A P
S A
N D
T R
A P
S A
N D
T R
A P
Y
D
M A
R K
S A
N D
T R
A P
S A
N D
T R
A P
Y
D
M A
R K
S A
N D
T R
A P
S A
N D
T R
A P
C H
IP
P
IN
G
G R
EE
N
S A
N D
T R
A P
S A
N D
T R
A
PS
A N
D T
R A
P
S A
N D
T R
A P
Y
D
M A
R K
Y
D
M A
R K
T E
E
P R
A C
TIC
E
G R
EE
N
P R
A C
TIC
E
G R
EE
N
S A
N D
T R
A P
S A
N D
T R
A P
S A
N D
T R
A P
S A
N D
T R
A P
F A
IR
W
A Y
F A
IR
W
A Y
F A
IR
W
A Y
F A
IR
W
A Y
F A
IR
W
A Y
F A
IR
W
A Y
F A
IR
W
A Y
F A
IR
W
A Y
F A
IR
W
A Y
F A
IR
W
A Y
F A
IR
W
A Y
F A
IR
W
A Y
F A
IR
W
A Y
F A
IR
W
A Y
F A
IR
W
A Y
F A
IR
W
A Y
F A
IR
W
A Y
G O
LF
C
O U
R S
E
F A
IR
W
A Y
F A
IR
W
A Y
S A
N D
T R
A P
G O
LF
C
O U
R S
E
F A
IR
W
A Y
F A
R M
G O
LF
C
O U
R S
E
G O
LF
C
O U
R S
E
G O
LF
C
O U
R S
E
F A
IRW
A
Y
F A
IRW
A
Y
G O
L F C
O U
R S
E
F A
IR
W
A Y
F A
IR
W
A Y G
O
LF
C O
U R
S E
F A
IR
W
A Y
F A
IR
W
A Y
B A
SE
B
AL
L
F
IEL
D
D U
G O
U T
D U
G O
U T
B
LE
A
CH
E R
S
BLEACHERS
W A
L L
S H
E D
W A
T E
R
T A
N K
R A
M P
/D O
C K
W A
L L
R A
M P
R A
M P
W A
L L
S H
E D
S H
E
DR
A
M P
P
IT
F U
E L
F A
R M
FUEL FARM
W A
L L
S L
A B
R A
M P
W A
L L
S H
E D
SHED
SLAB
S L
A B
S
LA
B
T A
N K
D O
M E
C O
N T
R O
L T
O W
E R
R A
M P
T O
W E
R
FU
E
L P U
M P
S
B
IK E
P A
T H
B
IK E
P A
T H
B
IK E
P A
T H
B
IK E
P A
T H
B
IK E
P A
T H
B
IK E
P A
T H
B
IK E
P A
T H
B
IK E
P A
T H
B
I KE
P A
TH
B A
SE
B
AL
L
F
IEL
D
D U
G O
U T
D U
G O
U T
B
LE
A
CH
E R
S
BLEACHERS
B
IK E
P A
T H
B
IK E
P A
T H
B
IK E
P A
T H
B
IK E
P A
T H
B
IK E
P A
T H
B
IK E
P A
T H
B
IK E
P A
T H
B
IK E
P A
T H
B
I KE
P A
TH
S T
A T
E R
O A D
A I A
S T
A T
E R
O A
D A
IA
S T
A T
E R
O A
D A
A
S T
A T
E R
O A
D A
A
S T
A T
E R
O A
D A
A
S T
A T
E R
O A
D A
A
S T
A T
E R
O A
D A
A
S T
A T
E R
O A
D A
A
S T
A T
E R
O A
D A
A
S T
A T
E R
O A
D A
A
R A N
G E
R O
A D
T
IT
A N
R O
A D
D E L
T A
D R
IV
E
S O
U T
H P
A T
R
IC
K D
R I V
E
S O
U T
H P
A T
R
IC
K D
R I V
E
M A
IN
T
EN
A N C
E R
O A
D
S O
U T H
P A
T R
IC
K D
R
IV
E
M A
IN
T E N
A N
C E R
O A D
CONTROL ROAD
W E
S T
T E
C H
R O
A D
S O
U T
H P
A T
R
IC
K D
R I V
E
C O
N T
R O
L R
O A
D
SOUTH TECH ROAD
S P
A C
E L
IF
T A V E
N U
E
F A L
C O
N A
V E
N U
E
F A L
C O
N A
V E N
U E
F A L
C O
N A
V E
N U
E
ATLAS AVENUE
ATLAS AVENUE
S O
U T
H P
A T
R I C
K D
R I V
E
SO UTH PATRICK DRIVE
S O
U T
H P
A T R
IC
K D
R I V
E
S P
A C
E L
IF
T A V E
N U
E
S P
A C
E L
IF
T A
V E
N U
E
CHALLENGER STREET
JUPITER STREET
SATURN ROAD
SATURN ROAD
PERSHING PLACE
MATADOR STREET
THOR STREET
ATLAS AVENUE
REDSTO NE ROAD
REDSTO NE ROAD
S P
A C
E L
IF
T A V E
N U
E
CONTROL ROAD
JUPITER STREET
S T
A T
E R
O A
D A
A
S T
A T E
R O
A D
A
A
S T
A T
E R
O A
D A
A
S T
A T E
R O
A D
A
A
S T
A T
E R
O A
D A
I A
S T
A T
E R
O A
D A
IA
O 'M
A L L E Y
R O
A D
O 'M
A L L E Y
R O
A D
R E S
C U
E R
O A D
R E S
C U
E R
O A D
R E S
C U
E R
O A D
RESCUE ROAD
R E
S C U
E R
O A
D
R E
S C
U E
R O
A D
R
IV
E R
S
ID
E T
R A
IL
R
IV
E R
S
ID
E T
R A
IL
R
IV
E R
S
ID
E T
R A
IL
R
IV
E R
S
ID
E T
R A
I L
R
IV
E R
S I D
E
T R
A
IL
RIVERSIDE
TRAIL
AN
GE
L F
I S
H C
O
VE
B
ON
I T
A C
O V
E
C
H E
R O
K E
E T
R A
I L
A
R A
P A
H O
T R
A
I L
CH
I
K A
S A
W
TR
A I L
IR
OQ
U O
I S
T
RA I L
P EQUO T TR AI L
SAN DOLL AR COVE
SE QUOI A TR A I L
SHOSHON I TR A I L
UTE TR AI L
S
TAR
FI SH
CO
V
E
S U R
FS
ID
E
CO
VE
SEA
M I S
T
CO
VE
C R
E E
T R A
I L
M A
R L
I N
C O
V E
M E
R M
A
ID
C O
V E
COM
A N
C H
E T
R A I L
C H
O C
T A
W
TR
A I L
H O
P I
T R
A I
L
PORPOI SE COVE
C O
Q U
IN
A
C O
V E
T U
S K
E G
E E A
IR
M
E N D
R
IV
E
EDW
ARD H. WHITE II
WASH
RAC K
RINSE
RAC K
N e w P a v i lio n
P a r C o u rs e
F it n e s s
C e n te r
P O
S T
O F
F
IC
E
T E
E
T E
E T
E E
T E
E
S A
N D
T R
A P
T E
E
L O
T
L O
T
L O
T
L O
T
L O
T
L O
T
L O
T
R E
E F
C O
U R
T
R E
E F
C O
UR
T
IN
S
TR
U
M E
N T
R U
N W
A Y
TAXIWAY "B"
TAXIW
AY "M"
T R
U E
A Z
IM
U
T H
.9
T R
U E
A Z
IM
U
T H
.9
TAXIWAY 'C'
TAXIWAY "C"
T A
X
IW
A Y
"B
' X
IN
S
T R
U M
E N
T R
U N
W A
Y
T A
X
IW
A Y
"A
T A
X
IW
A Y
"J"
TAXIW
AY "M"
200' X 4000'
T A
X
IW
A Y
"B " T A
X
IW
A Y
"A
RUNWAY 11/29
TAXIWAY "L"
TAXIWAY "G"
T A
X
IW
A Y
"Z
30103
5 830
57475753
57865780
5570 5556
5 24
533 6
52485254
5037 5031
5 032
CONTROL TOWER
AIRFIELD
122118
6 8
SLAB
734PS
TO
WER
HV
ACCO
OLI
NG
S T
O
RA
G E
D I
E S
E L
F
U E
L
G
A L
B A
N A
N A
R
IV
E R
A T
L A
N T
IC
O
C E
A N
PINEDA EXPRESSWAY
SOUTH GATE (PERSONNEL ONLY)
BUILDING 423-CONTRACTING OFFICER
BUILDING 535-45TH CES
S F
S B
U
IL
D
IN
G
C O
N S
T R
U C
T
IO
N
S.R. A1A
GOLF
COURSE
D O
M E
C O
N T
R O
L T
O W
E R
SPACE FORCE BASE
MIAMI
TAMPA
ORLANDO
PATRICK
TALLAHASSEE
JACKSONVILLE
PROJECT
AREA
N
N
S T
TA
E OF F OL R I
AD
ER
I
T
R E
G
IST
ED ARCH
T EC
AR0012815
BYRON L . TRAMONTE
54321 6
A
B
C
D
SHEET
IDENTIFICATION
U S
S F
T H
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
C O
N T
R A
C T
N O
F
A
-2
-D
DRAWN BY:
DESIGNED BY:
DATE:
REVIEWED BY:
SUBMITTED BY:
A
B
C
D
S P
A C
E S
P A
C E
P O
R T
A R
C H
IT
E
C T
U R
E C
IV
IL
E N
G
IN
E E
R
IN
G C
C S
F S
F
L
U
ES
I N
ET A T
S
D
E T
P AC
R F
N T
S
O C
E
C E
O
EH
R F
A IR
T O F
M
E D
R
T
P A
E
XIXMM
K. BROWN
PERMIT(S)/ENVIRONMENTAL ACTIONS
REQUIRED PRIOR TO CONSTRUCTION
ERP/STORMWATER
ERP/WETLANDS/DREDGE & FILL
FDEP/DRINKING WATER
FDEP/DOM. WASTE WATER
FDEP/IND. WASTE WATER
FDEP/FUEL TANK
NOI/SWPPP
IRP
SURVEY/WILDLIFE
ARCHEO./HISTORICAL
SLD45 RISK ASSESSMENT
NONE
NOTE: IF IT IS SUSPECTED THAT ANY HAZARDOUS MATERIALS NOT
IDENTIFIED ON THESE DRAWINGS IS REQUIRED TO BE DISTRIBUTED IN
ORDER TO PERFORM THE CONTRACT WORK, LEAVE MATERIAL
UNDISTURBED AND IMMEDIATELY INFORM THE CONTRACTING OFFICER.
HAZARDOUS MATERIALS YES NO
NOT
VERIFIED
ASBESTOS
HEAVY METALS
LEAD
PCB
GROUNDWATER CONTAMINATION
If this item has been electronically signed and sealed by the licensed professional named above using a digital signature and date. Printed copies of this document are not considered signed and sealed, and the signature must be verified on electronic copies.
To the best of the architect’s or engineer’s knowledge, the plans and specifications comply with the applicable minimum building codes and applicable fire safety standards as determined by the local authority in accordance with Florida Statutes chapters 553 and 633.
R E
P A
IR
R E
N O
V A
T E
P M
E L B
L D
G
G-001
C O
V E
R S
H E
E T
B. TREMONTE
J. GUYMON
07/09/2025
S X
H T
-1
A. FRANZONE
PATRICK SPACE FORCE BASE
FLORIDA
SXHT 16 -1028
REPAIR, RENOVATE PMEL BLDG
GENERAL SHEET INDEX
SHEET
NUMBER SHEET NAME 4
S U
B M
IT
T
A L
/0
/2
S U
B M
IT
T
A L
/0
/2
S U
B M
IT
T
A L
/2
/2
S U
B M
IT
T
A L
/0
/2
G-001 COVER SHEET ■ ■ ■ ■
GRAND TOTAL: 1
MECHANICAL SHEET INDEX
M-001 LEGENDS & GENERAL NOTES ■ ■ ■ ■
M-002 GENERAL NOTES ■ ■ ■ ■
MD-100 COMPOSITE HVAC DEMOLTION PLAN ■ ■ ■ ■
MD-101 ENLARGED HVAC DEMOLITION FLOOR PLAN ■ ■ ■ ■
MD-102 ENLARGED HVAC DEMOLITION FLOOR PLAN ■ ■ ■ ■
M-101 COMPOSITE HVAC FLOOR PLAN ■ ■ ■ ■
M-102 ENLARGED HVAC FLOOR PLANS ■ ■ ■ ■
M-103 ENLARGED HVAC FLOOR PLANS ■ ■
M-104 ENLARGED HVAC FLOOR PLANS ■ ■ ■ ■
M-105 ENLARGED HVAC FLOOR PLANS ■ ■
M-106 ENLARGED HVAC FLOOR PLANS ■ ■
M-501 MECHANICAL DETAILS ■ ■ ■ ■
M-502 MECHANICAL DETAILS ■ ■ ■ ■
M-601 MECHANICAL SCHEDULES ■ ■ ■ ■
M-701 MECHANICAL CONTROL DIAGRAMS ■ ■
M-702 MECHANICAL CONTROL DIAGRAMS ■ ■
M-703 MECHANICAL CONTROL DIAGRAMS ■ ■
M-704 MECHANICAL CONTROL DIAGRAMS ■ ■
M-705 MECHANICAL CONTROL DIAGRAMS ■ ■
GRAND TOTAL: 19
ELECTRICAL SHEET INDEX
E-001 LEGEND, ABBREVIATIONS, NOTES ■ ■ ■ ■
E-100 OVERALL ELECTRICAL PLAN ■ ■ ■ ■
ED-101A 1ST FLOOR - POWER PLAN - QUAD A - DEMOLITION ■ ■ ■ ■
ED-101B 1ST FLOOR - POWER PLAN - QUAD B - DEMOLITION ■ ■ ■ ■
ED-101C 1ST FLOOR - POWER PLAN - QUAD C - DEMOLITION ■ ■ ■ ■
ED-101D 1ST FLOOR - POWER PLAN - QUAD D - DEMOLITION ■ ■ ■ ■
E-101A 1ST FLOOR - POWER PLAN - QUAD A ■ ■ ■ ■
E-101B 1ST FLOOR - POWER PLAN - QUAD B ■ ■ ■ ■
E-101C 1ST FLOOR - POWER PLAN - QUAD C ■ ■ ■ ■
E-101D 1ST FLOOR - POWER PLAN - QUAD D ■ ■ ■ ■
E-601 ONE LINE DIAGRAM ■ ■ ■
E-701 PANEL SCHEDULES ■ ■ ■
E-702 PANEL SCHEDULES ■ ■
GRAND TOTAL: 13
FIRE ALARM SHEET INDEX
FA-001 FIRE ALARM NOTES AND DETAILS ■ ■ ■ ■
FAD-101 FIRE ALARM DEMO PLAN ■ ■ ■ ■
FA-101 PROPOSED FIRE ALARM FLOOR PLAN ■ ■ ■ ■
GRAND TOTAL: 3
STRUCTURAL SHEET INDEX
S-001 GENERAL NOTES ■ ■ ■ ■
SD-101 DEMO - SLAB PLAN ■ ■ ■ ■
SD-401 DEMO - ENLARGED SLAB PLANS ■ ■ ■ ■
S-101 OVERALL SLAB PLAN ■ ■ ■ ■
S-401 ENLARGED SLAB PLANS ■ ■ ■ ■
S-501 SECTIONS & DETAILS ■ ■ ■ ■
GRAND TOTAL: 6
LOCATION MAP
VICINITY MAP
ARCHITECTURAL SHEET INDEX
A-101 FLOOR PLAN ■ ■ ■ ■
GRAND TOTAL: 1
L ANGLE
ARCH ARCHITECT; ARCHITECTURAL
@ AT
CMU CONCRETE MASONRY UNIT
GALV GALVANIZED
LLV LONG LEG VERTICAL
MAX MAXIMUM
NTS; N.T.S. NOT TO SCALE
OC; O.C. ON CENTER
PSI POUNDS PER SQUARE INCH
THRU THROUGH
TYP TYPICAL
UNO; U.N.O. UNLESS NOTED OTHERWISE
VERT VERTICAL
W/ WITH
KSI KIPS PER SQUARE INCH
ABBREVIATIONS
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
AISI AMERICAN IRON AND STEEL INSTITUTE
ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS
AWS AMERICAN WELDING SOCIETY
ACI AMERICAN CONCRETE INSTITUTE
MIN MINIMUM
V.I.F. VERIFY IN FIELD
FLR FLOOR
FIN FINISH
MECH MECHANICAL
T/ TOP OF
EQUIP EQUIPMENT
POINT OF REFERENCE
EARTH
CONCRETE
SECTION LETTER
WHERE DRAWN
DETAIL NUMBER
WHERE DRAWN
ELEVATION
DESCRIPTIONSYMBOL
SYMBOLS AND LEGEND
NORTH
KEY NOTE
NORTH ARROW
X
S-XXX
S-XXX
X
DEMO
EXISTING GRID
MECHANICAL ANCHORS:
1. FOR POST-INSTALLED MECHANICAL ANCHORS INTO CONCRETE MASONRY, PRODUCTS SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ICC-ES AC01 OR ICC-ES106. ALL MASONRY CELLS TO RECEIVE ANCHORS SHALL BE GROUTED SOLID. INSTALLATION SHALL COMPLY WITH MANUFACTURER'S LATEST ICCC-ES APPROVAL PRE-APPROVED
ANCHORS INCLUDE:
2. SUBSTITUTION REQUESTS FOR PRODUCTS OTHER THAN THOSE LISTED ABOVE MAY BE SUBMITTED BY THE CONTRACTOR TO THE CONTRACTING OFFICER FOR REVIEW. SUBSTITUTIONS WILL ONLY BE CONSIDERED FOR PRODUCTS HAVING A CODE REPORT RECOGNIZING THE PRODUCT FOR THE APPROPRIATE APPLICATION. SUBSTITUTION REQUESTS SHALL INCLUDE CALCULATIONS DEMONSTRATING THE SUBSTITUTION IS THE EQUIVALENT CAPABLE OF ACHIEVING PERFORMANCE VALUES
OF THE PRE-APPROVED PRODUCTS.
3. MECHANICAL ANCHORS SHALL BE INSTALLED PER THE MANUFACTURER'S INSTRUCTIONS. THE CONTRACTOR SHALL CONTACT THE MANUFACTURER FOR PRODUCT INSTALLATION TRAINING. MANUFACTURER'S FIELD REPRESENTATIVE SHALL PROVIDE INSTALLATION TRAINING FOR ALL PRODUCTS TO BE USED, PRIOR TO COMMENCEMENT OF WORK. ONLY TRAINED INSTALLERS SHALL PERFORM POST INSTALLED ANCHOR INSTALLATION. A RECORD OF TRAINING SHALL BE KEPT ON SITE
AND BE MADE AVAILABLE TO THE CONTRACTING OFFICER AS REQUESTED.
A. SIMPSON STRONG-TIE STRONG-BOLT 2
B. SIMPSON STRONG-TIE TITEN HD
C. HILTI KWIK BOLT 3
D. HILTI KWIK KH-EZ
E. DEWALT POWER-STUD+ SD1
F. DEWALT SCREW-BOLT+
CONCRETE:
1.
5.
2. CONCRETE SHALL BE NORMAL WEIGHT CONCRETE EXCEPT AS NOTED. ALL CONCRETE STRENGTHS (AT 28 DAYS) SHALL BE AS
FOLLOWS:
FOUNDATIONS & SLABS ON GROUND
ALL CONCRETE WORK SHALL COMPLY WITH THE LATEST ADOPTED PROVISIONS OF ACI 318, AND ACI 301 AND THE APPLICABLE
CODES AND STANDARDS REFERENCED IN THE DESIGN STANDARDS.
PERMANENTLY EXPOSED TO EARTH) 3 INCHES
FOOTINGS, (CAST AGAINST &
STRUCTURAL ELEMENT CLEAR COVER
CONCRETE PROTECTION FOR REINFORCING (U.N.O):4.
3. CALCIUM CHLORIDE SHALL NOT BE USED IN ANY FORM.
6.
ALL REINFORCING STEEL SHALL BE PLACED WITHIN TOLERANCES SPECIFIED IN ACI 315.
7.
AT THE TIME CONCRETE IS PLACED, REINFORCEMENT SHALL BE FREE FROM MUD, OIL OR OTHER NONMETALLIC COATINGS
THAT DECREASE BOND.
DEFORMED REBAR (TYP UNO): FY = 60 KSI (A615, GRADE 60)
4000 PSI
CHAMFER EXPOSED CORNERS OF CONCRETE CONSTRUCTION WITH STANDARD 3/4" CHAMFERS, UNO.
1. THE CONTRACTOR IS REQUIRED TO PROVIDE ALL TEMPORARY SCAFFOLDING, PLATFORMS, BARRICADES, RAILINGS, SCREENING, ETC. NECESSARY TO PROTECT EXISTING FACILITIES, STRUCTURES AND THE PUBLIC DURING DEMOLITION AND ERECTION OF THE CONSTRUCTION, AS WELL AS FOR JOB SAFETY. JOB SAFETY, CONSTRUCTION AND DEMOLITION PROCEDURES ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONS TO MINIMIZE VIBRATION, NOISE, DUST AND DEBRIS IN ALL AREAS ADJACENT TO AREAS OF DEMOLITION.
DEMOLITION:
2. THE CONTRACTOR IS REQUIRED TO COORDINATE WITH THE CONTRACTING OFFICER FOR THE TEMPORARY SUSPENSION OF USE OF ANY FACILITY OR PORTION THEREOF, AND THE ASSOCIATED BARRICADING REQUIREMENTS WITHIN A MINIMUM OF 7
DAYS PRIOR TO COMMENCING WORK.
3. THE CONTRACTOR IS REQUIRED TO PERFORM HIS WORK IN A MANNER, WHICH WILL NOT CONFLICT WITH ANY OPERATION, WHICH IS TO REMAIN FUNCTIONAL DURING THE COURSE OF THE PROJECT, UNTIL SUCH OPERATION IS SCHEDULED TO BE SHUT
DOWN.
4. THE CONTRACTOR IS REQUIRED TO COORDINATE WITH THE CONTRACTING OFFICER FOR THE TEMPORARY SUSPENSION OF USE
OF ANY UTILITY SYSTEM, A MINIMUM OF 3 DAYS PRIOR TO COMMENCING WORK.
5. AT ALL LOCATIONS WHERE CONSTRUCTION WILL INTERFACE WITH EXISTING ELEMENTS, CUT THROUGH EXISTING STRUCTURE
IN STRAIGHT AND TRUE LINES TO ENSURE A NEAT INTERFACE.
6. AT ALL LOCATIONS WHERE THE DEMOLITION OF A CONCRETE MEMBER LEAVES THE ENDS OF REINFORCING STEEL EXPOSED, PROVIDE THE FOLLOWING:
7. BEFORE DEMOLISHING ANY STRUCTURAL ELEMENT, INSTALL ALL REQUIRED TEMPORARY AND/OR PERMANENT BRACING AND
SUPPORTS.
8. PROVIDE TEMPORARY CLOSURE OF ALL ROOF FASCIA, WALL AND OTHER OPENINGS TO PROTECT BUILDING FROM EXPOSURE TO UNDESIRABLE ELEMENTS UNTIL CONSTRUCTION IS WEATHERPROOFED, AT WHICH TIME SUCH TEMPORARY CONSTRUCTION SHALL BE REMOVED. ALL TEMPORARY EXTERIOR WALLS THAT ARE SUBJECT TO WIND LOADS ARE TO BE DESIGNED BY A
DELEGATED ENGINEER.
9. UPON COMPLETION OF CONSTRUCTION UNDER EACH PHASE, ALL DEMOLISHED AREAS SHALL BE RESTORED TO ACCEPTABLE USAGE ACCORDING TO THE CONTRACT DOCUMENTS AS DETERMINED BY THE CONTRACTING OFFICER.
10. REMOVE COMPLETELY FROM THE SITE AND LEGALLY DISPOSE ALL DEBRIS GENERATED BY THE DEMOLITION WORK AS THE WORK PROGRESSES. STOCKPILING OF DEBRIS AND BURNING OF DEBRIS ON THE PREMISES IS STRICTLY PROHIBITED.
A. CHIP CONCRETE FROM AROUND THE STEEL TO A DEPTH OF 1".
B. CUT OFF REINFORCING STEEL NOT LESS THAN 3/4" BELOW THE CONCRETE SURFACE.
C. FILL THE CAVITY FLUSH WITH A HIGH MODULUS GEL EPOXY.
11. CONTRACTOR'S OPTION TO ENLARGE MECHANICAL EQUIPMENT PADS IN LIEU OF REPLACING. COORDINATE PAD LOCATIONS AND
SIZE WITH MECHANICAL DRAWINGS AND EQUIPMENT MANUFACTURER'S RECOMMENDATIONS.
54321 6
A
B
C
D
SHEET
IDENTIFICATION
U S
S F
T H
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
C O
N T
R A
C T
N O
F
A
-2
-D
DRAWN BY:
DESIGNED BY:
DATE:
REVIEWED BY:
SUBMITTED BY:
A
B
C
D
S P A C E
S P
A C
E P
O R
T A
R C
H
IT
E C
T U
R E
C
IV
IL
E
N G
IN
E
E R
IN
G
C C
S F
S
F L
U
ES
I N
ET A T
S
D
E T
P AC
R F
N T
S
O C
E
C E
O
EH
R F
A IR
T O F
M
E D
R
T
P A
E
XIXMM
K. BROWN
If this item has been electronically signed and sealed by the licensed professional named above using a digital signature and date. Printed copies of this document are not considered signed and sealed, and the signature must be verified on electronic copies.
To the best of the architect’s or engineer’s knowledge, the plans and specifications comply with the applicable minimum building codes and applicable fire safety standards as determined by the local authority in accordance with Florida Statutes chapters 553 and 633.
R E
P A
IR
R E
N O
V A
T E
P M
E L
B L D
G
S-001
G E
N E
R A
L N
O T
E S
M. ROHAUS
K. WHITE
07/09/2025
S X
H T
-1
A. FRANZONE
GENERAL NOTES:
ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT, EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN.
THE CONTRACTOR SHALL WORK STRUCTURAL DRAWINGS TOGETHER WITH ARCHITECTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS AS APPLICABLE TO LOCATE DEPRESSED SLABS, SLOPES, DRAINS, REGLETS, BOLT SETTINGS, GRADES, ETC. ANY DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF THE CONTRACTING OFFICER BEFORE PROCEEDING WITH THE WORK. DO NOT PENETRATE STRUCTURAL ELEMENTS (BEAMS, COLUMNS, WALLS, SLABS, STEEL DECKS, ETC.) WITHOUT
PRIOR WRITTEN APPROVAL OF THE CONTRACTING OFFICER.
THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CONNECTIONS, EMBED PLATE AND ANCHOR BOLT LOCATIONS FROM EQUIPMENT MANUFACTURER'S APPROVED DRAWINGS AND STEEL FABRICATOR'S ANCHOR BOLT AND EMBED PLATE SETTING
PLANS, WHICH HAVE BEEN APPROVED BY THE CONTRACTING OFFICER.
ALL MATERIALS AND WORKMANSHIP SHALL COMPLY WITH PROJECT DRAWINGS AND SPECIFICATIONS2.
3.
6.
9.
1. DESIGN IS BASED ON THE APPLICABLE CODES AND STANDARDS REFERENCED IN THE DESIGN STANDARDS.
THE CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, ELEVATIONS AND CONDITIONS PRIOR TO ORDERING ANY MATERIALS AND SHALL NOTIFY THE CONTRACTING OFFICER IF DIFFERENT FROM WHAT IS SHOWN ON THE DRAWINGS.
4.
THE CONTRACTOR SHALL REVIEW THESE DRAWINGS AND VISIT THE PROJECT SITE BEFORE CONSTRUCTION BEGINS TO COMPARE ALL EXISTING CONDITIONS WITH WHAT IS SHOWN ON THESE DRAWINGS. IF THERE ARE CONDITIONS WHICH ARE
DIFFERENT FROM WHAT IS SHOWN, THE CONTRACTING OFFICER SHALL BE NOTIFIED.
7.
8.
ALL STRUCTURES ARE DESIGNED TO BE STABLE AND SELF-SUPPORTING IN THEIR COMPLETED CONSTRUCTED STATE AT THE END OF CONSTRUCTION. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND SEQUENCES THAT ENSURE THE STABILITY OF STRUCTURES AND ITS COMPONENTS DURING CONSTRUCTION. THIS INCLUDES BUT IS NOT LIMITED TO THE ADDITION OF SUPPORTS, BRACING, GUYS WIRES, TIE DOWNS, SHORING AND RE-SHORING. SUCH TEMPORARY SUPPORTS SHALL BE DESIGNED BY QUALIFIED REGISTERED PROFESSIONAL ENGINEERS RETAINED BY THE CONTRACTOR, IN ACCORDANCE WITH LOCAL STATUTES AND REGULATIONS. TEMPORARY SUPPORTS SHALL REMAIN THE PROPERTY OF THE CONTRACTOR AND INFORMATION RELATED TO THEM IS NOT INCLUDED IN THE CONTRACT DOCUMENTS.
5.
SHOP DRAWING SUBMITTALS:
A. CONTRACTOR SHALL SUBMIT TO THE CONTRACTING OFFICER FOR REVIEW SHOP DRAWINGS FOR ALL APPLICABLE TRADES
IN ACCORDANCE WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS.
B. IN ORDER TO EXPEDITE REVIEW OF SHOP DRAWINGS BY CONTRACTING OFFICER AND AVOID ANY NEED FOR RE-SUBMITTAL BY THE CONTRACTOR, SUBMITTED SHOP DRAWINGS SHALL BE COMPLETE WITH ADEQUATE AND NECESSARY INFORMATION
SHOWN TO FACILITATE THEIR REVIEW.
C. CONTRACTOR SHALL REVIEW THE SHOP DRAWINGS THOROUGHLY AND VERIFY DIMENSIONS, ELEVATIONS, QUANTITIES, ETC. BEFORE SUBMITTING TO THE CONTRACTING OFFICER FOR REVIEW. SHOP DRAWINGS NOT REVIEWED AND MARKED
APPROVED BY THE CONTRACTOR WILL BE REJECTED AND RETURNED.
D. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION BETWEEN SHOP DRAWINGS AND DRAWINGS OF DIFFERENT TRADES. ANY FIELD ISSUES AS A RESULT OF THE LACK OF SUCH COORDINATION SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR.
10.
DO NOT SCALE THE STRUCTURAL DRAWINGS TO DETERMINE DIMENSIONS OR MATERIAL QUANTITIES.
DESIGN STANDARDS:
1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE BUILDING CODE AND PUBLICATIONS LISTED BELOW. IN THE CASE OF
CONFLICTING REQUIREMENTS, THE BUILDING CODE SHALL GOVERN.
2. APPLICABLE CODES AND STANDARDS:
BUILDING CODE
ACI 318-19
TMS 402/602-22
AISC 360-22
AISI S100-16(2020) w/S2-20
ASCE 7-22
AWS D1.1-D1.1M-2020
SLD 45 IFS (22 APRIL 2024)
G04 SLD 45 IFS STRUCTURES STANDARDS
(1 JANUARY 2024)
UFC 1-200-01 (CHANGE 3, FEBRUARY 2024)
UFC 3-301-01 (CHANGE 1, 02 OCTOBER 2023)
FC 4-218-01F - PMEL FACILITIES CRITERIA
INTERNATIONAL BUILDING CODE 2024 (IBC). (INCLUDING BUILDING
CODE AMENDMENTS SPECIFIC TO THE PROJECT SITE
JURISDICTION)
AMERICAN CONCRETE INSTITUTE, "BUILDING CODE REQUIREMENTS
FOR STRUCTURAL CONCRETE AND COMMENTARY"
THE MASONRY SOCIETY, "BUILDING CODE REQUIREMENTS AND
SPECIFICATIONS FOR MASONRY STRUCTURES"
AMERICAN INSTITUTE OF STEEL CONSTRUCTION, "SPECIFICATION
FOR STRUCTURAL STEEL BUILDINGS"
AMERICAN IRON AND STEEL INSTITUTE, "NORTH AMERICAN
SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL
STRUCTURAL MEMBERS"
AMERICAN SOCIETY OF CIVIL ENGINEERS, "MINIMUM DESIGN LOADS
AND ASSOCIATED CRITERIA FOR BUILDINGS AND OTHER
STRUCTURES"
AMERICAN WELDING SOCIETY, "STRUCTURAL WELDING
CODE - STEEL"
SPACE LAUNCH DELTA 45 INSTALLATION FACILITY STANDARDS
SPACE LAUNCH DELTA 45 INSTALLATION FACILITY STANDARDS
STRUCTURES STANDARDS
UNIFIED FACILITIES CRITERIA, DOD BUILDING CODE
UNIFIED FACILITIES CRITERIA, STRUCTURAL ENGINEERING
FACILITIES CRITERIA FOR PRECISION MEASUREMENT EQUIPMENT
LABORATORY DESIGN AND CONSTRUCTION
DESIGN CRITERIA:
DESIGN WIND LOAD: (PER ASCE 7)2.
OCCUPANCY RISK CATEGORY II
EXPOSURE CATEGORY C
ULTIMATE WIND SPEED, Vult 149 MPH
NOMINAL WIND SPEED, Vasd 116 MPH
ENCLOSURE CLASSIFICATION ENCLOSED
INTERNAL PRESSURE COEFFICIENT ±0.18
1. DESIGN DEAD LOADS:
MECHANICAL EQUIPMENT SELF WEIGHT
F L O R I D
A
P R
O F
E
S S
I O N A L E N G
I N
E E
R
M
W E R
L I C E N S E
No. 82400
STATE OF
ATTHE OHAUS
UP
UP
A
SD-401
SD-401
SD-401
SD-401
SD-401
SD-401
DRAWING NOTES:
1. SEE SHEET S-001 FOR GENERAL NOTES AND ABBREVIATIONS.
54321 6
A
B
C
D
SHEET
IDENTIFICATION
U S
S F
T H
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
C O
N T
R A
C T
N O
F
A
-2
-D
DRAWN BY:
DESIGNED BY:
DATE:
REVIEWED BY:
SUBMITTED BY:
A
B
C
D
S P A C E
S P
A C
E P
O R
T A
R C
H
IT
E C
T U
R E
C
IV
IL
E
N G
IN
E
E R
IN
G
C C
S F
S
F L
U
ES
I N
ET A T
S
D
E T
P AC
R F
N T
S
O C
E
C E
O
EH
R F
A IR
T O F
M
E D
R
T
P A
E
XIXMM
K. BROWN
If this item has been electronically signed and sealed by the licensed professional named above using a digital signature and date. Printed copies of this document are not considered signed and sealed, and the signature must be verified on electronic copies.
To the best of the architect’s or engineer’s knowledge, the plans and specifications comply with the applicable minimum building codes and applicable fire safety standards as determined by the local authority in accordance with Florida Statutes chapters 553 and 633.
R E
P A
IR
R E
N O
V A
T E
P M
E L
B L D
G
SD-101
D E
M O
S
L A
B P
L A
N
M. ROHAUS
K. WHITE
07/09/2025
S X
H T
-1
A. FRANZONE
SCALE: 1/16" = 1'-0"1
DEMO - SLAB PLAN
0 8' 16' 32' 48'
SCALE: 1/16" = 1'-0"
NORTH
KEY PLAN
B
A
E
D
F
C
F L O R I D
A
P R
O F
E
S S
I O N A L E N G
I N
E E
R
M
W E R
L I C E N S E
No. 82400
STATE OF
A
2 2
DRAWING NOTES:
1. SEE SHEET S-001 FOR GENERAL NOTES AND ABBREVIATIONS.
KEYNOTES:
1. DEMOLISH CONCRETE PAD TO BE FLUSH WITH SURROUNDING SLAB.
2. DEMOLISH CONCRETE PEDESTALS TO BE FLUSH WITH SURROUNDING SLAB.
2A-A
SD-401
A-A
54321 6
A
B
C
D
SHEET
IDENTIFICATION
U S
S F
T H
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
C O
N T
R A
C T
N O
F
A
-2
-D
DRAWN BY:
DESIGNED BY:
DATE:
REVIEWED BY:
SUBMITTED BY:
A
B
C
D
S P A C E
S P
A C
E P
O R
T A
R C
H
IT
E C
T U
R E
C
IV
IL
E
N G
IN
E
E R
IN
G
C C
S F
S
F L
U
ES
I N
ET A T
S
D
E T
P AC
R F
N T
S
O C
E
C E
O
EH
R F
A IR
T O F
M
E D
R
T
P A
E
XIXMM
K. BROWN
If this item has been electronically signed and sealed by the licensed professional named above using a digital signature and date. Printed copies of this document are not considered signed and sealed, and the signature must be verified on electronic copies.
To the best of the architect’s or engineer’s knowledge, the plans and specifications comply with the applicable minimum building codes and applicable fire safety standards as determined by the local authority in accordance with Florida Statutes chapters 553 and 633.
R E
P A
IR
R E
N O
V A
T E
P M
E L
B L D
G
SD-401
D E
M O
E
N L A
R G
E D
S L A
B P
L A
N S
M. ROHAUS
K. WHITE
07/09/2025
S X
H T
-1
A. FRANZONE
SCALE: 1/4" = 1'-0"1
EQUIP PAD DEMO PLAN - AREA A, AHU-01, 02, & 03
SCALE: 1/4" = 1'-0"2
EQUIP PAD DEMO PLAN - AREA B, AHU-04
SCALE: 1/4" = 1'-0"4
EQUIP PAD DEMO PLAN - AREA D, AHU-06
SCALE: 1/4" = 1'-0"5
EQUIP PAD DEMO PLAN - AREA E, AHU-09 & 10
SCALE: 1/4" = 1'-0"6
EQUIP PAD DEMO PLAN - AREA F, AHU-11 & 12
SCALE: 1/4" = 1'-0"3
EQUIP PAD DEMO PLAN - AREA C, AHU-05
0 2' 4' 8' 12'
SCALE: 1/4" = 1'-0"
NORTH
KEY PLAN
B
A
E
D
F
C
F L O R I D
A
P R
O F
E
S S
I O N A L E N G
I N
E E
R
M
W E R
L I C E N S E
No. 82400
STATE OF
S-401
S-401
S-401
S-401
S-401
S-401
DRAWING NOTES:
1. SEE SHEET S-001 FOR GENERAL NOTES AND ABBREVIATIONS.
54321 6
A
B
C
D
SHEET
IDENTIFICATION
U S
S F
T H
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
C O
N T
R A
C T
N O
F
A
-2
-D
DRAWN BY:
DESIGNED BY:
DATE:
REVIEWED BY:
SUBMITTED BY:
A
B
C
D
S P A C E
S P
A C
E P
O R
T A
R C
H
IT
E C
T U
R E
C
IV
IL
E
N G
IN
E
E R
IN
G
C C
S F
S
F L
U
ES
I N
ET A T
S
D
E T
P AC
R F
N T
S
O C
E
C E
O
EH
R F
A IR
T O F
M
E D
R
T
P A
E
XIXMM
K. BROWN
If this item has been electronically signed and sealed by the licensed professional named above using a digital signature and date. Printed copies of this document are not considered signed and sealed, and the signature must be verified on electronic copies.
To the best of the architect’s or engineer’s knowledge, the plans and specifications comply with the applicable minimum building codes and applicable fire safety standards as determined by the local authority in accordance with Florida Statutes chapters 553 and 633.
R E
P A
IR
R E
N O
V A
T E
P M
E L
B L D
G
S-101
O V
E R
A L L S
L A
B P
L A
N
M. ROHAUS
K. WHITE
07/09/2025
S X
H T
-1
A. FRANZONE
SCALE: 1/16" = 1'-0"1
OVERALL SLAB PLAN
0 8' 16' 32' 48'
SCALE: 1/16" = 1'-0"
NORTH
KEY PLAN
B
A
E
D
F
C
F L O R I D
A
P R
O F
E
S S
I O N A L E N G
I N
E E
R
M
W E R
L I C E N S E
No. 82400
STATE OF
5' -3
9"
1"
4' -8
4"
4'-8"
11'-11" 7"
4' -7
'-4
11'-6" 4"
7'-3" 7'-0"
'-1
0"
1 5' -3
8" 4'-10" 5'-6"
A
1' -1
0" 9'
-4
6" 6'-2"
5'-7" 7'-0"
S-501
1' -9
'-4
1 1
1'-5" 6'-8" 8'-0" 5'-2" 1'-9"
1" 9'
-1 0"
1" 9'
-1 0"
DRAWING NOTES:
1. SEE SHEET S-001 FOR GENERAL NOTES AND ABBREVIATIONS.
2. CONTRACTOR'S OPTION TO ENLARGE MECHANICAL EQUIPMENT PADS IN LIEU
OF REPLACING. COORDINATE PAD LOCATIONS AND SIZE WITH MECHANICAL
DRAWINGS AND EQUIPMENT MANUFACTURER'S RECOMMENDATIONS.
KEYNOTES:
1. HOUSEKEEPING PAD. SEE TYPICAL DETAIL ON S-501.
VERIFY SIZE WITH APPROVED EQUIPMENT SHOP DRAWINGS PRIOR TO
POURING, COORDINATE LOCATIONS WITH MECHANICAL DRAWINGS.
1'-10" 5'-10"
1' -9
6'
-4
54321 6
A
B
C
D
SHEET
IDENTIFICATION
U S
S F
T H
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
C O
N T
R A
C T
N O
F
A
-2
-D
DRAWN BY:
DESIGNED BY:
DATE:
REVIEWED BY:
SUBMITTED BY:
A
B
C
D
S P A C E
S P
A C
E P
O R
T A
R C
H
IT
E C
T U
R E
C
IV
IL
E
N G
IN
E
E R
IN
G
C C
S F
S
F L
U
ES
I N
ET A T
S
D
E T
P AC
R F
N T
S
O C
E
C E
O
EH
R F
A IR
T O F
M
E D
R
T
P A
E
XIXMM
K. BROWN
If this item has been electronically signed and sealed by the licensed professional named above using a digital signature and date. Printed copies of this document are not considered signed and sealed, and the signature must be verified on electronic copies.
To the best of the architect’s or engineer’s knowledge, the plans and specifications comply with the applicable minimum building codes and applicable fire safety standards as determined by the local authority in accordance with Florida Statutes chapters 553 and 633.
R E
P A
IR
R E
N O
V A
T E
P M
E L
B L D
G
S-401
E N
L A
R G
E D
S L A
B P
L A
N S
M. ROHAUS
K. WHITE
07/09/2025
S X
H T
-1
A. FRANZONE
SCALE: 1/4" = 1'-0"1
EQUIP PAD PLAN - AERA A, AHU-01, 02, & 03
SCALE: 1/4" = 1'-0"2
EQUIP PAD PLAN - AREA B, AHU-04
SCALE: 1/4" = 1'-0"4
EQUIP PAD PLAN - AREA D, AHU-06
SCALE: 1/4" = 1'-0"5
EQUIP PAD PLAN - AREA E, AHU-09 & 10
SCALE: 1/4" = 1'-0"6
EQUIP PAD PLAN - AREA F, AHU-11 & 12
SCALE: 1/4" = 1'-0"3
EQUIP PAD PLAN - AREA C, AHU-05
0 2' 4' 8' 12'
SCALE: 1/4" = 1'-0"
NORTH
KEY PLAN
B
A
E
D
F
C
F L O R I D
A
P R
O F
E
S S
I O N A L E N G
I N
E E
R
M
W E R
L I C E N S E
No. 82400
STATE OF
O V
E F
IN
F
LR
U N
O
S E
E M
E C
H D
R A
W
IN
G S
NOTE:
1. COORDINATE PAD LOCATIONS AND SIZE WITH MECHANICAL
DRAWINGS AND EQUIPMENT MANUFACTURER'S RECOMMENDATIONS
2. EQUIPMENT MANUFACTURER SHALL COMPLY WITH FC 4-218-01F -
PMEL FACILITIES CRITERIA.
ROUGHEN TO 1/4" AMPLITUDE & APPLY
BONDING AGENT
ADHESIVE ANCHORS, REFER TO
EQUIPMENT SHOP DRAWINGS FOR TYPE,
SIZE, PROJECTION AND LOCATION
SEE NOTE
MIN
6"
#4@12" OC, EW
CENTERED
C U
R B
H E
IG
H
T
(M
IN
T/ EXISTING SLAB
NOTE: CONTRACTOR'S OPTION TO ENLARGE PAD IN
LIEU OF REPLACING. COORDINATE PAD LOCATIONS
AND SIZE WITH MECHANICAL DRAWINGS AND
EQUIPMENT MANUFACTURER'S RECOMMENDATIONS.
ROUGHEN TO 1/4" AMPLITUDE & APPLY
BONDING AGENT
ADHESIVE ANCHORS & MOUNTING
HARDWARE, REFER TO EQUIPMENT
SHOP DRAWINGS FOR TYPE, SIZE,
PROJECTION AND LOCATION
SEE NOTE
MIN
6"
C U
R B
H E
IG
H
T
M A
T C
H E
X
IS
T
IN
G
T/ SLAB
#4 @ 12" O.C. EACH WAY
12" MINIMUM
VARIES
EXISTING SLAB
ON GRADE
CMU CRACKS KEY NOTES:
1. VERTICAL CRACKS - RAKE CRACK AND INSTALL
FLEXIBLE EPOXY CRACK FILLER.
2. HORIZONTAL CRACKS - AT STRUCTURAL
SUPPORTING LINTELS. RAKE AND REPOINT AT
MORTAR JOINTS, INJECT EPOXY AT CRACKS
THAT ARE NOT ON A JOINT.
54321 6
A
B
C
D
SHEET
IDENTIFICATION
U S
S F
T H
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
C O
N T
R A
C T
N O
F
A
-2
-D
DRAWN BY:
DESIGNED BY:
DATE:
REVIEWED BY:
SUBMITTED BY:
A
B
C
D
S P A C E
S P
A C
E P
O R
T A
R C
H
IT
E C
T U
R E
C
IV
IL
E
N G
IN
E
E R
IN
G
C C
S F
S
F L
U
ES
I N
ET A T
S
D
E T
P AC
R F
N T
S
O C
E
C E
O
EH
R F
A IR
T O F
M
E D
R
T
P A
E
XIXMM
K. BROWN
If this item has been electronically signed and sealed by the licensed professional named above using a digital signature and date. Printed copies of this document are not considered signed and sealed, and the signature must be verified on electronic copies.
To the best of the architect’s or engineer’s knowledge, the plans and specifications comply with the applicable minimum building codes and applicable fire safety standards as determined by the local authority in accordance with Florida Statutes chapters 553 and 633.
R E
P A
IR
R E
N O
V A
T E
P M
E L
B L D
G
S-501
S E
C T
IO
N
S
D E
T A
IL
S
M. ROHAUS
K. WHITE
07/09/2025
S X
H T
-1
A. FRANZONE
SCALE: 3/4" = 1'-0"1
TYPICAL INTERIOR HOUSEKEEPING PAD
SCALE: 3/4" = 1'-0"2
ENLARGED EXISTING INTERIOR
HOUSEKEEPING PAD DETAIL
SCALE: NTS3
CMU WALL REPAIR DETAIL
0 1' 2' 3' 4'
SCALE: 3/4" = 1'-0"
F L O R I D
A
P R
O F
E
S S
I O N A L E N G
I N
E E
R
M
W E R
L I C E N S E
No. 82400
STATE OF
UP
DN
DN
DN
A
SMC/PERATON
SMC/RGNEXT
SMC/RGNEXT
HALL-1
MECH
SMC/PELP
29C
SMC/PELP
29B
SMC/PELP
29A
SMC/RGNEXT
SMC/PELP
SMC/MILVETS
SMC/MILVET
SMC/MILVET
SMC/PERATON
SMC/RGNEXT
COMMON AREA
44B
45RANS/PMEL
44A
45RANS/PMEL
MECH5
15A
45RANS/PMEL
Room
RR1
JAN1
RR3
RR2
45RANS/PMEL
COMMON AREA
50B
45RANS/PMEL
50A
45RANS/PMEL
SMC/RGNEXT
45RANS/PMEL
45RANS/PMEL
MECH7
17A
SMC/RGNEXT
SMC/PELP
SMC/RGNEXT
154A
SMC/PERATON
SMC/PERATON
156A
SMC/PELP
SMC/RGNEXT
SMC/RGNEXT
SMC/PELP
SMC/AEROSPACE
SMC/AEROSPACE
SMC/PELP
SMC/PELP
SMC/PELP
SMC/PELP
SMC/RGNEXT
20A
SMC/RGNEXT
SMC/RGNEXT
SMC/PELP
SMC/PELP
134A
SMC/PELP
SMC/PELP
133A
45/RANS/PMEL
45RANS/PMEL
51A
COMMON AREA
COMMON AREA
SMC/PELP
127 SMC/PELP
SMC/SE&I
SMC/SE&I
SMC/PELP
SMC/MILVETS
SMC/MILVETS
124A
SMC/MILVETS
118A
COMMON AREA
SMC/PELP
SMC/PELP
COMMON AREA
123A
COMMON AREA
123B
COMMON AREA
123C
MECH8
18A
JAN2
45RANS/PMEL
55A
45RANS/PMEL
45RANS/PMEL
55C
COMMON
55B
HALL3
45RANS/PMEL
45RANS/PMEL
45RANS/PMEL
50C
45RANS/PMEL
58A
45RANS/PMEL
45RANS/PMEL
SMC/PELP
SMC/PELP/CC
101A
SMC/PELP/CD
101B
SMC/PELP/CCS
SMC/PELP
SMC/PELP
SMC/PELP/DO
107A
MECH9
19A
SMC/PELP
SMC/PELP
SMC/PELP
SMC/PELP
SMC/PELP
SMC/PELP
120A
SMC/PELP
WORKER/ADMIN
120B
SMC/PELP
SMC/PELP
SMC/PELP
SMC/PELP
SMC/PELP
SMC/PELP
SMC/PELP
WORKER/ADMIN
HALL4
28' - 0"
ELEC.
29D
MEZZANINE ABOVE
SMC/RGNEXT
SMC/RGNEXT
A-101
A-101
A-101
DEMOLISH
EXISTING DUCT
AND PATCH
FLOOR
5/8" GWB FINISH TO
LEVEL 4 AND PAINT
ON 3 5/8" 20G MTL
STUDS CHASE
2' - 8 1/2"
/2
6"
1' - 8"
NEW MECHANICAL
DUCT
MEZZANINE
12' - 6"
REMOVE EXISTING DUCT
NEW DUCT LOCATION,
SEE MECH.
FURRED
ENCLOSED NEW
DUCT
EXISTING GYPSUM
BOARD CEILING
S T
TA
E OF F OL R I
AD
ER
I
T
R E
G
IST
ED ARCH
T EC
AR0012815
BYRON L . TRAMONTE
54321 6
A
B
C
D
SHEET
IDENTIFICATION
U S
S F
T H
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
C O
N T
R A
C T
N O
F
A
-2
-D
DRAWN BY:
DESIGNED BY:
DATE:
REVIEWED BY:
SUBMITTED BY:
A
B
C
D
S P A C E
S P
A C
E P
O R
T A
R C
H
IT
E C
T U
R E
C
IV
IL
E
N G
IN
E
E R
IN
G
C C
S F
S
F L
U
ES
I N
ET A T
S
D
E T
P AC
R F
N T
S
O C
E
C E
O
EH
R F
A IR
T O F
M
E D
R
T
P A
E
XIXMM
K. BROWN
If this item has been electronically signed and sealed by the licensed professional named above using a digital signature and date. Printed copies of this document are not considered signed and sealed, and the signature must be verified on electronic copies.
To the best of the architect’s or engineer’s knowledge, the plans and specifications comply with the applicable minimum building codes and applicable fire safety standards as determined by the local authority in accordance with Florida Statutes chapters 553 and 633.
R E
P A
IR
R E
N O
V A
T E
P M
E L B
L D
G
A-101
F L O
O R
P L A
N
B. TREMONTE
J. GUYMON
07/09/2025
S X
H T
-1
A. FRANZONE
1/16" = 1'-0"1
FIRST FLOOR PLAN
0 8' 16' 32' 48'
1/16" = 1'-0"
NORTH
1/16" = 1'-0"2
MEZZANINE FLOOR PLAN
1/4" = 1'-0"3
NEW DUCTING DETAIL
1/4" = 1'-0"4
DUCTING SECTION
0 2' 4' 8' 12'
1/4" = 1'-0"
KEY PLAN
B
A
E
D
F
C
LOC
" 5
MANUAL PULL
STATION
FMCU
FSA
T O
SPEAKER/STROBE
WALL-MOUNTED
SPEAKER
TEXT
FIRE ALARM AND MASS NOTIFICATION SYSTEM SEQUENCE OF OPERATION MATRIX
MANUAL PULL STATION
ALARM AT
FMCU AND
FSA
SUPERVISORY
AT FMCU AND
FSA
TROUBLE
AT FMCU
AND FSA
ALARM AT
RECEIVING
STATION
TROUBLE AT
RECEIVING
STATION
SUPERVISORY
AT RECEIVING
STATION
ACTIVATE
SPEAKERS/
STROBES
SHUTDOWN
RESPECTIVE
AHU
SMOKE DETECTOR
DUCT SMOKE DETECTOR
IMPUT FROM CAMPUS-WIDE
MASS NOTIFICATION SYSTEM
ALARM SILENCE
(FMCU OR FSA)
AC POWER FAIL
LOW BATTERY
OVERRIDE FA
MESSAGE (IF
SIMULTANEOUSLY
ACTIVE)
FMCU TROUBLE CONDITIONS
(OPENS, GROUNDS, SHORTS)
FMCU MICROPHONE
DEACTIVATE
SPEAKERS/
STROBES
WATERFLOW SWITCH
TAMPER SWITCH
EXTERIOR WATER
FLOW BELL (NON-
SILENCEABLE)
ACTIVATE
CORRESPONDING
MESSAGE ON
TEXT DISPLAY
INPUT FROM LOC
FMCU
SPEAKER/
STROBES
MANUAL PULL
STATIONS
SMOKE
DETECTORS
TO 120 VAC
P P
STROBES
SPD
SPEAKER/
STROBES
SPEAKER/
STROBES
30 30 75 75
SPEAKER/
STROBES
15 15
SPEAKER/
STROBES
15 15
SPEAKER/
STROBES
110 110
FSA
DUCT SMOKE
DETECTORS
AHU
SHUTDOWN
RR
XMIT
TEXT TEXT
EOL
EOL
STROBES
SPEAKER
LOCLOC
MANUAL PULL STATION
FIRE ALARM AND MNS STROBE WITH CLEAR LENS,
WALL MOUNTED
XX = CANDELA RATING
FIRE ALARM AND MASS NOTIFICATION SPEAKER
(CEILING-MOUNTED)
FIRE ALARM AND MASS NOTIFICATION
CONTROL UNIT
MONITOR MODULE
PHOTOELECTRIC SMOKE DETECTOR
INDICATES WEATHERPROOFWP
DUCT SMOKE DETECTOR
LOCAL OPERATOR CONSOLE (RECESSED)
WITH REMOTE MICROPHONE AND HVAC
SHUTDOWN SWITCH
RELAY MODULE
LOC
MM
FMCU
R
FIRE ALARM LEGEND
P
XX
FSA FIRE ALARM REMOTE ANNUNCIATOR
PANEL (RECESSED)
FIRE ALARM AND MNS SPEAKER/STROBE WITH
CLEAR LENS, WALL MOUNTED
XX = CANDELA RATING
XX
FIRE ALARM AND MASS NOTIFICATION SPEAKER
XMIT TRANSMITTER
TEXT TEXT MESSAGE SIGN
FIRE ALARM SPEAKER/STROBE LOCATION WITH
CLEAR AND AMBER LENS (EXISTING)
XX = CANDELA RATING
FIRE ALARM SPEAKER/STROBE LOCATION WITH
CLEAR AND AMBER LENS (EXISTING)
(CEILING-MOUNTED)
FIRE ALARM AND MASS NOTIFICATION SPEAKER
(CEILING-MOUNTED) (EXISTING)
FIRE ALARM AND MASS NOTIFICATION SPEAKER
(EXISTING)
FIRE ALARM NOTES
1. THE SCOPE OF WORK INCLUDES REPLACING THE EXISTING FIRE ALARM AND
MASS NOTIFICATION SYSTEM WITH A COMBINATION FIRE ALARM AND MASS
NOTIFICATION SYSTEM THROUGHOUT IN ACCORDANCE WITH UFC 3-600-01 AND
NFPA 72.
2. PROVIDE AN ADDRESSABLE COMBINATION FIRE ALARM AND MASS
NOTIFICATION SYSTEM (MNS) IN ACCORDANCE WITH NFPA 72, UFC 4-021-01,
G12 SLD45 IFS FA & MNS, THE SPECIFICATION AND THE SCOPE OF WORK
DOCUMENTS. THE NEW FIRE ALARM/MASS NOTIFICATION CONTROL UNIT
MUST BE A MONACO MAAP-X AND COMMUNICATE WITH THE PATRICK BASE
FIRE DEPARTMENT'S MONACO D-21 CENTRAL RECEIVING STATION.
3. AIR HANDLING UNITS OVER 2,000 CFM MUST HAVE DUCT SMOKE DETECTORS
INSTALLED ON THE SUPPLY AND RETURN DUCTS.
4. THE EXISTING FIRE ALARM SYSTEM MUST REMAIN INTACT AND OPERATIONAL
FOR THE DURATION OF THE PROJECT. AFTER FINAL ACCEPTANCE OF THE
NEW FIRE ALARM AND MASS NOTIFICATION SYSTEM BY THE BASE, THE
CONTRACTOR MUST REMOVE AND PROPERLY DISPOSE OF ALL EXISTING
DEVICES, PANELS, WIRING AND CONDUIT TO THE EXTENT POSSIBLE.
5. ALL INTERIOR AND EXTERIOR WALLS, CEILINGS AND FLOORS THAT ARE
DAMAGED OR ALTERED BY THE CONTRACTOR MUST BE RESTORED TO
ORIGINAL CONDITION AND TO THE SATISFACTION OF THE CONTRACTING
OFFICER. THIS INCLUDES REPAIRS OF DAMAGE TO WALLS AND CEILINGS
CAUSED BY DEMOLITION OF THE EXISTING SYSTEM.
6. THE FIRE ALARM AND MASS NOTIFICATION SYSTEM LAYOUT IS
DIAGRAMMATICAL ONLY. THE ACTUAL BUILDING LAYOUT MAY VARY FROM THE
DRAWINGS. THE CONTRACTOR MUST VERIFY DEVICE LOCATIONS, CEILING
HEIGHTS, WALL AND PARTITION LOCATIONS AND DOOR LOCATIONS PRIOR TO
INSTALLATION.
7. THE CONTRACTOR IS RESPONSIBLE FOR REMOVING ANY AND ALL ABANDONED
FIRE ALARM CABINETS, DEVICES, AND WIRE. CONTRACTOR IS RESPONSIBLE
FOR CLEANUP, PATCHING, REPAIRING, AND PAINTING.
54321 6
A
B
C
D
SHEET
IDENTIFICATION
U S
S F
T H
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
C O
N T
R A
C T
N O
F
A
-2
-D
DRAWN BY:
DESIGNED BY:
DATE:
REVIEWED BY:
SUBMITTED BY:
A
B
C
D
S P A C E
S P
A C
E P
O R
T A
R C
H
IT
E C
T U
R E
C
IV
IL
E
N G
IN
E
E R
IN
G
C C
S F
S
F L
U
ES
I N
ET A T
S
D
E T
P AC
R F
N T
S
O C
E
C E
O
EH
R F
A IR
T O F
M
E D
R T
P A
E
XIXMM
K. BROWN
If this item has been electronically signed and sealed by the licensed professional named above using a digital signature and date. Printed copies of this document are not considered signed and sealed, and the signature must be verified on electronic copies.
To the best of the architect’s or engineer’s knowledge, the plans and specifications comply with the applicable minimum building codes and applicable fire safety standards as determined by the local authority in accordance with Florida Statutes chapters 553 and 633.
R E
P A
IR
R E
N O
V A
T E
P M
E L
B L D
G
FA-001
F
IR
E A
L A
R M
N O
T E
S A
N D
D E
T A
IL
S
W. HIGGINS
C. MANTSCH
07/09/2025
S X
H T
-1
K. POTHIER
NOT TO SCALEFA-001
3 FIRE ALARM ELEVATION (TYPICAL)
NOT TO SCALEFA-001
1 SEQUENCE OF OPERATION MATRIX
NOT TO SCALEFA-001
2 RISER DIAGRAM
SMC/PERATON
SMC/RGNEXT
SMC/RGNEXT
HALL-1
MECH
SMC/PELP
29C
SMC/PELP
29B
SMC/PELP
29A
SMC/RGNEXT
SMC/PELP
SMC/MILVETS
SMC/MILVET
SMC/MILVET
SMC/PERATON
SMC/RGNEXT
COMMON AREA
44B
45RANS/PMEL
44A
45RANS/PMEL
MECH5
45RANS/PMEL
Room
RR1
JAN1
RR3
RR2
6 45RANS/PMEL
COMMON AREA
50B
45RANS/PMEL
50A
45RANS/PMEL
SMC/RGNEXT
45RANS/PMEL
45RANS/PMEL
MECH7
SMC/RGNEXT
SMC/PELP
SMC/RGNEXT
154A
SMC/PERATON
SMC/PERATON
156A
SMC/PELP
SMC/RGNEXT
SMC/RGNEXT
SMC/PELP
SMC/AEROSPACE
SMC/AEROSPACE
SMC/PELP
136 SMC/PELP
SMC/PELP
SMC/PELP
SMC/RGNEXT
20A
SMC/RGNEXT
SMC/RGNEXT
SMC/PELP
SMC/PELP
134A
SMC/PELP
SMC/PELP
133A
45/RANS/PMEL
45RANS/PMEL
51A
COMMON AREA
COMMON AREA
SMC/PELP
SMC/PELP
SMC/SE&I
SMC/SE&I
SMC/PELP
SMC/MILVETS
SMC/MILVETS
124A
SMC/MILVETS
118A
COMMON AREA
SMC/PELP
SMC/PELP
COMMON AREA
123A
COMMON AREA
123B
COMMON AREA
123C
MECH8
JAN2
45RANS/PMEL
55A
45RANS/PMEL
45RANS/PMEL
55C
COMMON
55B
HALL3
45RANS/PMEL
45RANS/PMEL
45RANS/PMEL
50C
45RANS/PMEL
58A
45RANS/PMEL
45RANS/PMEL
SMC/PELP
SMC/PELP/CC
101A
SMC/PELP/CD
101B
SMC/PELP/CCS
SMC/PELP
SMC/PELP
SMC/PELP/DO
107A
MECH9
SMC/PELP
SMC/PELP
SMC/PELP
SMC/PELP
SMC/PELP
SMC/PELP
120A
SMC/PELP
WORKER/ADMIN
120B
SMC/PELP
SMC/PELP
SMC/PELP
SMC/PELP
SMC/PELP
SMC/PELP
SMC/PELP
WORKER/ADMIN
HALL4
F M
C U
P
P
P
LOC P
P
P
P
P
MM
MM
MM
MM
MM
MM
DEMO EXISTING
ANTENNA
DEMOLISH ALL EXISTING FIRE ALARM INITIATING
DEVICES, NOTIFICATION APPLIANCES, CONDUIT
AND WIRE IN AREAS BEING RENOVATED
FIRE ALARM DEMOLITION LEGEND
SMC/RGNEXT
SMC/RGNEXT
P
FIRE ALARM NOTES
1. SEE SHEET FA-001 FOR FIRE ALARM AND MASS NOTIFICATION
SYSTEM NOTES AND DETAILS.
2. EXISTING SYSTEM MUST REMAIN OPERATIONAL UNTIL NEW
SYSTEM IS COMPLETELY INSTALLED, TESTED, AND ACCEPTED
BY THE CONTRACTING OFFICER.
54321 6
A
B
C
D
SHEET
IDENTIFICATION
U S
S F
T H
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
C O
N T
R A
C T
N O
F
A
-2
-D
DRAWN BY:
DESIGNED BY:
DATE:
REVIEWED BY:
SUBMITTED BY:
A
B
C
D
S P A C E
S P
A C
E P
O R
T A
R C
H
IT
E C
T U
R E
C
IV
IL
E
N G
IN
E
E R
IN
G
C C
S F
S
F L
U
ES
I N
ET A T
S
D
E T
P AC
R F
N T
S
O C
E
C E
O
EH
R F
A IR
T O F
M
E D
R T
P A
E
XIXMM
K. BROWN
If this item has been electronically signed and sealed by the licensed professional named above using a digital signature and date. Printed copies of this document are not considered signed and sealed, and the signature must be verified on electronic copies.
To the best of the architect’s or engineer’s knowledge, the plans and specifications comply with the applicable minimum building codes and applicable fire safety standards as determined by the local authority in accordance with Florida Statutes chapters 553 and 633.
R E
P A
IR
R E
N O
V A
T E
P M
E L
B L D
G
FAD-101
F
IR
E A
L A
R M
D E
M O
P L A
N
W. HIGGINS
C. MANTSCH
07/09/2025
S X
H T
-1
K. POTHIER
1/16" = 1'-0"1
FIRE ALARM DEMOLITION - FIRST FLOOR PLAN
1/16" = 1'-0"2
FIRE ALARM DEMOLITION - MEZZANINE FLOOR
PLAN
0 8' 16' 32' 48'
1/16" = 1'-0"
NORTH
SMC/PERATON
SMC/RGNEXT
SMC/RGNEXT
HALL-1
MECH
SMC/PELP
29C
SMC/PELP
29B
SMC/PELP
29A
SMC/RGNEXT
SMC/PELP
SMC/MILVETS
SMC/MILVET
SMC/MILVET
SMC/PERATON
SMC/RGNEXT
COMMON AREA
44B 45RANS/PMEL
44A
45RANS/PMEL
MECH5
45RANS/PMEL
Room
RR1
JAN1
RR3
RR2
45RANS/PMEL
COMMON AREA
50B
45RANS/PMEL
50A
45RANS/PMEL
SMC/RGNEXT
45RANS/PMEL
45RANS/PMEL
MECH7
SMC/RGNEXT
SMC/PELP
SMC/RGNEXT
154A
SMC/PERATON
SMC/PERATON
156A
SMC/PELP
SMC/RGNEXT
157 SMC/RGNEXT
SMC/PELP
SMC/AEROSPACE
SMC/AEROSPACE
SMC/PELP
SMC/PELP
SMC/PELP
SMC/PELP
SMC/RGNEXT
20A
SMC/RGNEXT
SMC/RGNEXT
SMC/PELP
SMC/PELP
134A
SMC/PELP
SMC/PELP
133A
45/RANS/PMEL
45RANS/PMEL
51A
COMMON AREA
COMMON AREA
SMC/PELP
127 SMC/PELP
SMC/SE&I
SMC/SE&I
SMC/PELP
SMC/MILVETS
SMC/MILVETS
124A
SMC/MILVETS
118A
COMMON AREA
SMC/PELP
SMC/PELP
COMMON AREA
123A
COMMON AREA
123B
COMMON AREA
123C
MECH8
JAN2
45RANS/PMEL
55A
45RANS/PMEL
45RANS/PMEL
55C
COMMON
55B
HALL3
45RANS/PMEL
45RANS/PMEL
45RANS/PMEL
50C
45RANS/PMEL
58A
45RANS/PMEL
45RANS/PMEL
SMC/PELP
SMC/PELP/CC
101A SMC/PELP/CD
101B
SMC/PELP/CCS
SMC/PELP
SMC/PELP
SMC/PELP/DO
107A
MECH9
SMC/PELP
SMC/PELP
SMC/PELP
SMC/PELP
SMC/PELP
SMC/PELP
120A
SMC/PELP
WORKER/ADMIN
120B
SMC/PELP
SMC/PELP
SMC/PELP
SMC/PELP
SMC/PELP
SMC/PELP
SMC/PELP
WORKER/ADMIN
HALL4
PP
P
P
P
P
P
P P
P
P
P
P
P
30 30 30 30
75 30
75 75
30 30
30 3015 15
30 30
30 30
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
FMCU
TEXT
T E
X T
TEXTTEXT
T E
X T
T E
X T
TEXT TEXT
T E
X T
TEXT
F S
A
LOC
15 15
15 15
NEW MONITOR
MODULES FOR
SPRINKLER VALVES
NEW RADIO
ANTENNA
MM
MM
MM
MM
R
R
L O
C
WP
HALL4
P
SMC/RGNEXT
SMC/RGNEXT
75 75
FIRE ALARM NOTES
1. SEE SHEET FA-001 FOR FIRE ALARM AND MASS NOTIFICATION
SYSTEM NOTES AND DETAILS.
2. EXISTING SYSTEM MUST REMAIN OPERATIONAL UNTIL NEW
SYSTEM IS COMPLETELY INSTALLED, TESTED, AND ACCEPTED
BY THE CONTRACTING OFFICER.
54321 6
A
B
C
D
SHEET
IDENTIFICATION
U S
S F
T H
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
C O
N T
R A
C T
N O
F
A
-2
-D
DRAWN BY:
DESIGNED BY:
DATE:
REVIEWED BY:
SUBMITTED BY:
A
B
C
D
S P A C E
S P
A C
E P
O R
T A
R C
H
IT
E C
T U
R E
C
IV
IL
E
N G
IN
E
E R
IN
G
C C
S F
S
F L
U
ES
I N
ET A T
S
D
E T
P AC
R F
N T
S
O C
E
C E
O
EH
R F
A IR
T O F
M
E D
R T
P A
E
XIXMM
K. BROWN
If this item has been electronically signed and sealed by the licensed professional named above using a digital signature and date. Printed copies of this document are not considered signed and sealed, and the signature must be verified on electronic copies.
To the best of the architect’s or engineer’s knowledge, the plans and specifications comply with the applicable minimum building codes and applicable fire safety standards as determined by the local authority in accordance with Florida Statutes chapters 553 and 633.
R E
P A
IR
R E
N O
V A
T E
P M
E L
B L D
G
FA-101
P R
O P
O S
E D
F
IR
E A
L A
R M
F L O
O R
P L A
N
W. HIGGINS
C. MANTSCH
07/09/2025
S X
H T
-1
K. POTHIER
1/16" = 1'-0"1
FIRE ALARM - FIRST FLOOR PLAN
1/16" = 1'-0"2
FIRE ALARM - MEZZANINE FLOOR PLAN
0 8' 16' 32' 48'
ABBR DESCRIPTION
MECHANICAL ABBREVIATIONS
ABBR DESCRIPTION
A COMPRESSED AIR
AC AIR CONDITIONER
A/C AIR CONDITIONING
ACCTWP AIR COMPRESSOR COOLING TOWER WATER PUMP
ACU AIR HANDLING UNIT
AD ACCESS DOOR
AF AIRFOIL
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFMS AIRFLOW MEASUREMENT STATION
AHU AIR HANDLING UNIT
ALT ALTERNATE
AP ACCESS PANEL
ASHRAE AMERICAN SOCIETY OF HEATING,
REFRIGERATION, AND AIR CONDITIONING ENGINEERS
ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS
BAS BUILDING AUTOMATION SYSTEM
BHP BREAK HORSEPOWER
BOD BOTTOM OF DUCT
BTU BRITISH THERMAL UNIT PER HOUR
CAP CAPACITY
C/C CENTER OF CENTER
CENTRI CENTRIFUGAL
CFM CUBIC FEET PER MINUTE
CH CHILLER
CHW CHILLED WATER
CHWP CHILLED WATER PUMP
CHWS/R CHILLED WATER SUPPLY/RETURN
CONN CONNECTION
CONT CONTINUE
COP COEFFICIENT OF PERFORMANCE
CO2 CARBON DIOXIDE
CT COOLING TOWER
CTW COOLING TOWER WATER
CTWP COOLING TOWER WATER PUMP
CTWS/R COOLING TOWER WATER SUPPLY/RETURN
CWP CONDENSER WATER PUMP
CU CONDENSING UNIT
DB DRY BULB
DG DOOR GRILLE
DL DOOR LOUVER
DDC DIRECT DIGITAL CONTROL
DIA DIAMETER
DIFF DIFFERENTIAL
DN DOWN
DP DIFFERENTIAL PRESSURE
DR DRYER
DWG DRAWING
DX DIRECT EXPANSION
EA EXHAUST AIR
EAG EXHAUST AIR GRILLE
EAR EXHAUST AIR REGISTER
EAT ENTERING AIR TEMPERATURE
ECO EXTERIOR CLEAN OUT
EDH ELECTRIC DUCT HEATER
EER ENERGY EFFICIENCY RATIO
EF EXHAUST FAN
EFF EFFICIENCY
ELEC ELECTRIC, ELECTRICAL
EQUIP EQUIPMENT
ESP EXTERNAL STATIC PRESSURE
EWT ENTERING WATER TEMPERATURE
EXIST EXISTING
°F DEGREES FAHRENHEIT
FA FACE AREA
FACP FIRE ALARM CONTROL PANEL
FAS FIRE ALARM SYSTEM
FC FORWARD CURVE
FCU FAN COIL UNIT
FLD FLOOR DRAIN
FLEX FLEXIBLE
FLG FLANGE
FLR FLOOR
FPS FEET PER SECOND
FT FEET
FTU FAN TERMINAL UNIT
FV FACE VELOCITY
GA GAUGE
GALV GALVANIZED
GPM GALLONS PER MINUTE
GTH GRAND TOTAL HEAT
H2O WATER
HD HEAD
HDT HORIZONTAL DRAW THRU
HHWS/R HEATING HOT WATER SUPPLY/RETURN
HP HORSEPOWER
H/P HEAT PUMP
HR HOUR
HRU HEAT RECOVERY UNIT
HVAC HEATING, VENTILATION AND AIR CONDITIONING
HWP HEATING HOT WATER PUMP
HX HEAT EXCHANGER
HZ HERTZ
IAC INDUSTRIAL AIR COMPRESSOR
IH INFRARED HEATER
IN INCHES
IST ICE STORAGE TANK
KW KILOWATTS
LAT LEAVING AIR TEMPERATURE
LDS LEAK DETECTION SENSOR
LPG LIQUID PETROLEUM GAS
LRA LOCKED ROTOR AMPS
LVR LOUVER
LWT LEAVING WATER TEMPERATURE
MAU MAKE-UP AIR UNIT
MAX MAXIMUM
MBH 1000 BRITISH THERMAL UNITS PER HOUR
MCA MINIMUM CIRCUIT AMPACITY
MECH MECHANICAL
MEZZ MEZZANINE
MFS MAXIMUM FUSE SIZE
MIN MINIMUM
MOCP MAXIMUM OVER CURRENT PROTECTION
MVD MANUAL VOLUME DAMPER
NC NORMALLY CLOSED
N/C NOISE CRITERIA
NEC NATIONAL ELECTRIC CODE
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NOM NOMINAL
NTS NOT TO SCALE
OA OUTSIDE AIR
OAL OUTSIDE AIR LOUVER
OAT OUTSIDE AIR TEMPERATURE
OAU OUTSIDE AIR UNIT
OC ON CENTER
ODP OPEN DRIP PROOF
PCHWP PRIMARY CHILLED WATER PUMP
PCT PERCENT
PD PRESSURE DROP
PH PHASE
POC POINT OF CONNECTION
PROP PROPELLER
PRS PRESSURE REDUCING STATION
PRV PRESSURE REDUCING VALVE
PSIG POUNDS PER SQUARE INCH GAUGE
PTAC PACKAGED TERMINAL AIR CONDITIONER
RA RETURN AIR
RAG RETURN AIR GRILLE
RAR RETURN AIR REGISTER
RAT RETURN AIR TEMPERATURE
REF REFRIGERANT
RH RELATIVE HUMIDITY
RHC REHEAT COIL
RHP ROOFTOP HEAT PUMP
RLA RATED LOAD AMPS
RM ROOM
RPM REVOLUTION PER MINUTE
RTU ROOFTOP UNIT
RV ROOF VENT
SA SUPPLY AIR
SAG SUPPLY AIR GRILLE
SAR SUPPLY AIR REGISTER
SAT SUPPLY AIR TEMPERATURE
SATT SOUND ATTENUATOR
SCH SCHEDULE
SCHWP SECONDARY CHILLER WATER PUMP
SD SUPPLY DIFFUSER
SEC SECOND
SEER SEASONAL ENERGY EFFICIENCY RATIO
SMACNA SHEET METAL AND AIR CONDITIONING
CONTRACTORS' NATIONAL ASSOCIATION
SF SUPPLY FAN
SG SOFFIT GRILLE
SHT SHEET
SP STATIC PRESSURE
SQ SQUARE
SS STAINLESS STEEL
SSF SIDE STREAM FILTER
STL STEEL
STM STEAM
TAG TRANSFER AIR GRILLE
TAR TRANSFER AIR REGISTER
TEAO TOTALLY ENCLOSED AIR OVER
TEFC TOTALLY ENCLOSED FAN COOLED
TEMP TEMPERATURE
TSH TOTAL SENSIBLE HEAT
TSP TOTAL STATIC PRESSURE
TSTAT THERMOSTAT
TYP TYPICAL
TOD TOP OF DUCT
TOS TOP OF STEEL
U/G UNDER GROUND
UH UNIT HEATER
UL UNDERWRITER'S LABORATORIES
UNO UNLESS NOTED OTHERWISE
V VOLTS, VOLTAGE
VAV VARIABLE AIR VOLUME
VDT VERTICAL DRAW THRU
VFD VARIABLE FREQUENCY DRIVE
VLV VALVE
VVT VARIABLE VOLUME AND TEMPERATURE
W WATT(S)
W/ WITH
WB WET BULB
WG WATER GAGE
WH WALL HEATER
WSHP WATER SOURCE HEAT PUMP
ZD ZONE DAMPER
SYMBOL ABBR DESCRIPTION DESCRIPTIONSYMBOL ABBR
COOLING TOWER WATER SUPPLYCTWSCTWS
COOLING TOWER WATER RETURNCTWRCTWR
CHILLED WATER SUPPLYCHWSCHWS
CHILLED WATER RETURNCHWRCHWR
PIPE END CAP
PIPE TURNING DOWN OR AWAY
PIPE TURNING UP OR TOWARD
PIPE TEE TURNING DOWN OR AWAY
INDICATES SUPPLY AIR FLOW DIRECTION
HATCHING INDICATES PIPING OR EQUIPMENT TO BE REMOVED
THIN LINEWORK INDICATES EXISTING PIPING OR EQUIPMENT
CD CD CONDENSATE DRAIN - INDIRECT
ROUND DUCT SECTION TURNED
UP OR TOWARDS
AD DUCT ACCESS DOOR
END OF DUCT WITH CAP (UNLESS
NOTED OTHERWISE)
SMOKE DAMPER WITH ACCESS
DOOR IN DUCT
FIRE/SMOKE DAMPER WITH
ACCESS DOOR IN DUCT
SQUARE TO ROUND TRANSITION
ECCENTRIC DUCT TRANSITION
RECTANGULAR DUCT SIZE IN INCHES FIRST
SIZE LISTED IS SIDE SHOWN
DUCT SECTIONS UP
THROUGH SLAB OR ROOF
SUPPLY AIR DUCT SECTION TURNED
UP OR TOWARDS
EXISTING DUCT
DUCT TO BE DEMOLISHED
BACKDRAFT DAMPER
CONCENTRIC DUCT TRANSITION
FIRE DAMPER W/ACCESS
DOOR IN DUCT
FLEXIBLE DUCT
MANUAL VOLUME DAMPER
18"x12"
SUPPLY AIR DUCT SECTION TURNED
DOWN OR AWAY
RETURN AIR DUCT SECTION
TURNED DOWN OR AWAY
RETURN AIR DUCT SECTION
TURNED UP OR TOWARDS
EXHAUST AIR DUCT SECTION
TURNED UP OR TOWARDS
EXHAUST AIR DUCT SECTION
TURNED DOWN OR AWAY
ROUND DUCT SIZE IN INCHES18"Ø
DUCT OFFSET (DOWN) IN DIRECTION OF
ARROW (NOT TYPICALLY SHOWN)
DUCT OFFSET (UP) IN DIRECTION OF
ARROW (NOT TYPICALLY SHOWN)
ROUND DUCT SECTION TURNED
DOWN OR AWAY
BDD
FD
FSD
SMD
MVD
GRILLE, REGISTER OR OPEN DUCT
(SUPPLY SHOWN)
AIR DISTRIBUTION LEGEND PIPING LEGEND
CEILING SUPPLY DIFFUSER. REFER TO DIFFUSER
AND GRILLE SCHEDULE FOR ADDITIONAL
INFORMATION.
LINEAR SLOT DIFFUSER. REFER TO DIFFUSER AND
GRILLE SCHEDULE FOR ADDITIONAL INFORMATION.
CEILING GRILLE (RETURN OR TRANSFER) REFER TO
DIFFUSER AND GRILLE SCHEDULE FOR ADDITIONAL
INFORMATION.
CEILING EXHAUST GRILLE. REFER TO DIFFUSER
AND GRILLE SCHEDULE FOR ADDITIONAL
INFORMATION.
INDICATES RETURN OR EXHAUST AIR FLOW DIRECTION
UP
DN
HEATING HOT WATER SUPPLYHHWSHHWS
HEATING HOT WATER RETURNHHWRHHWR
IMMERSION TEMPERATURE TRANSMITTER WITH THERMOWELL
DUCT SMOKE DETECTOR
AIR FLOW MEASURING STATION
AIR TEMPERATURE SENSOR
3-WAY CONTROL VALVE WITH 24V ACTUATOR UNO
2-WAY BUTTERFLY VALVE WITH 24V ACTUATOR UNO
SPACE TEMPERATURE SENSOR
SPACE RELATIVE HUMIDITY SENSOR
DIGITAL INPUT OR OUTPUT
STARTER
CURRENT SENSOR/TRANSMITTER
DRY CONTACT
ANALOG INPUT OR OUTPUT
CONTROLS LEGEND
THERMOSTAT
FLOW METER
VARIABLE FREQUENCY DRIVE
EMERGENCY PUSHBUTTON
LIGHT
DIFFERENTIAL PRESSURE SENSOR/TRANSMITTER
HORN AND STROBE
DIFFERENTIAL PRESSURE INDICATING TRANSMITTER
OPPOSED BLADE CONTROL DAMPER WITH 24V ACTUATOR UNO
PARALLEL BLADE CONTROL DAMPER WITH 24V ACTUATOR UNO
VIBRATION SWITCH
CARBON DIOXIDE SENSOR/TRANSMITTER
STATIC PRESSURE SENSOR/TRANSMITTER
DESCRIPTIONSYMBOL
COMMUNICATIONS INTERFACE
PIPE CONTINUATION
UC 75
UNDERCUT
CARBON MONOXIDE SENSOR/TRANSMITTER
PIPE WITH ARROW INDICATING FLOW DIRECTION
CT
STR
F
T
F
M
M
M
T
H
T
VS
C
CO2
DP
VFD
SP
T
M
M
12"x8" 8"Ø
FLEXIBLE DUCT CONNECTION
T
F FREEZESTAT (ACROSS COIL FACE)
AVERAGING TEMP SENSOR (ACROSS COIL FACE)
BALANCING VALVEBAL VA
SHUTOFF VALVE (AS SPECIFIED FOR PIPING SYSTEM)
COMBINATION BALANCING/SHUTOFF VALVEBSV
NEEDLE VALVENV
BUTTERFLY VALVEBFV
RELIEF VALVERV
PRESSURE GAUGEPG
BASKET STRAINERB STR
THERMOMETERTH
PRESSURE SWITCH
AUTOMATIC FLOW CONTROL VALVEAFCV
Y-TYPE STRAINERSTR
FLOW MEASUREMENT STATIONFMS
OUTSIDE SCREW AND YOKE VALVEOSY VA
PRESSURE REDUCING VALVEPRV
TEST PLUGTP
FLOW SWITCH
UNION
CHECK VALVECKV
SOLENOID VALVE (TWO-POSITION W/ ACTUATOR)
GLOBE VALVEGLV
BALL VALVEBV
AAV AUTOMATIC AIR VENT
MANUAL AIR VENT
THREADED DRAIN PLUG
PUMP (DIAGRAM)
FLEXIBLE CONNECTOR
ECCENTRIC REDUCER (NOT TYPICALLY SHOWN)
FLANGES
MALE (GARDEN) HOSE CONNECTION WITH CAP
INDICATES ASSEMBLY OF PIPING COMPONENTS (AS
NOTED OR DIAGRAMMED)
ALIGNMENT GUIDE
PIPE ANCHOR
MAV
WATER METER
CONCENTRIC REDUCER (NOT TYPICALLY SHOWN)
PRESSURE INDEPENDENT CONTROL VALVE
MAGNEHELIC DIFFERENTIAL PRESSURE GAUGE
M
PIPE TURNING DOWN OR AWAY
PIPE TURNING UP OR TOWARD
PIPE TURNING DOWN OR AWAY
PIPE TURNING UP THROUGH SLAB OR ROOF
PUMP SUCTION DIFFUSERPSD
PIPE TEE TURNING UP OR TOWARD
SPACE TEMPERATURE AND RELATIVE HUMIDITY SENSOR
WITH LCD SCREEN AND INTERFACE
TH
TRIPLE - DUTY VALVETDV
2-WAY CONTROL VALVE WITH 24V ACTUATOR UNO
AIRFLOW MEASUREMENT STATIONAFMS
DDC DIGITAL DOWN
DDC DIGITAL UP
DDC ANALOG DOWN
DDC ANALOG UP
CONTROLLER IO
FAMILY TYPE
D D
C T
E X
T
D D
C T
E X
T
INTERFACE
SYMBOL
D D
C T
E X
T
D D
C T
E X
T
D D
C T
E X
T
D D
C T
E X
T
D D
C T
E X
T
D D
C T
E X
T
D D
C T
E X
T
D D
C T
E X
T
P R
O F
E S
S
I O NA L
E N G
I N
E E
R
L I CENSE
F L O R I DA
STATE
No. 62945
D
ANI L UINE Q
O N
E S
54321 6
A
B
C
D
SHEET
IDENTIFICATION
U S
S F
T H
C
IV
IL
E
N G
IN
E
E R
S Q
U A
D R
O N
C O
N T
R A
C T
N O
F
A
-2
-D
DRAWN BY:
DESIGNED BY:
DATE:
REVIEWED BY:
SUBMITTED BY:
A
B
C
D
S P A C E
S P
A C
E P
O R
T A
R C
H
IT
E C
T U
R E
C
IV
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .