XRF Lead Report_WH-28_ p.1
Defense Logistics Agency - San Joaquin Tracy, California
XRF Lead Evaluation
Date: 27 June 2017 Subject: Field Analysis for Suspect Lead Paint Bulk Sample Collected from the DLASJ Tracy, Warehouse 28
Evaluation
On 27 June 2017, field testing for the presence of Lead was performed on the primary structural coatings (paints) identified on the surfaces of the building materials at the DLASJ, Tracy, Warehouse 28. Robert Miller, Certified Industrial Hygienist, and Lonny Jones, Industrial Hygiene Technician, performed the field sample analysis utilizing a handheld Innov-X Systems, Alpha Series, X-Ray Fluorescence (XRF) Spectrometer. Prior to this sampling event the calibration of the XRF instrument was verified by performing an analysis of a National Institute of Standards & Technology (NIST), Reference Material. The field testing data for Warehouse 28 is provided in Table 1 of this report.
Table 1 Sample Number
Coating / Paint Description Lead Concentration
0627-28-01 Warehouse Exterior: Blue on concrete walls Non-Detect (ND) 0627-28-02 Warehouse Exterior: Yellow on handrails at stairwell ND 0627-28-03 Warehouse Exterior: Yellow on I-beam bumpers on west dock
ND
0627-28-04 Warehouse Exterior: Blue on metal pedestrian door ND 0627-28-05 Warehouse Exterior: Blue on dock leveler ND 0627-28-06 Bubble Interior: White on walls ND 0627-28-07 Bubble Interior: White on pedestrian doors ND 0627-28-08 Warehouse Interior: White on walls ND 0627-28-09 Warehouse Interior: Yellow on former fire door columns >5.0 mg/cm2 0627-28-10 Warehouse Interior: Yellow on bumper around vent ND 0627-28-11 Warehouse Interior: Yellow on cargo door (peeling) ND 0627-28-12 Warehouse Interior: Red on fire risers ND 0627-28-13 Warehouse Interior: Red on steel I-beams ND 0627-28-14 Warehouse Interior: Red on concrete base of I-beam >5.0 mg/cm2 0627-28-15 Warehouse Interior: Yellow on guardrails ND 0627-28-16 Warehouse Interior: Safety yellow on floor ND 0627-28-17 Warehouse Interior: Yellow on steel beams, “Recoup” area ND 0627-28-18 Warehouse Interior: White on walls, “Recoup” hallway ND 0627-28-19 Warehouse Interior: Yellow on wood bumpers on docks ND 0627-28-20 Warehouse Interior: Yellow on steel I-beams (Section 4A) ND
XRF Lead Report_WH-28_ p.2
Discussion The field testing of the coatings associated with the DLASJ Tracy, Warehouse 28, did identify
Lead concentrations that are described in Table 1 of this report. The Federal OSHA 29 CFR
1926.62 and 29 CFR 1910.1025 Standards and California OSHA 8CCR 1532.1, and Title 17 CCR Standards regulate exposures to materials with any detectable amount of Lead.
Recommendations
• Any activity that may include the disturbance of Lead-containing materials must be performed within the regulations set forth in Federal OSHA 29 CFR 1926.62, 29 CFR
1910.1025 and California OSHA 8CCR 1532.1, and Title 17 CCR Standards.
• Disposal of any building materials that are coated with Lead-containing paint must be disposed of per the requirements of the DS-FJ Installation Support Environmental Office.
Robert Miller, CIH Certified Industrial Hygienist