Lead_Report_Warehouse_13.pdf

PDF 67 KB Posted

Attached to
Paint the interior walls of offices and adjacent areas of Buildings
Solicitation number
SP330017B0014
Issued by

About this file

Lead Report Warehouse 13

View the file

Other files

File Type Posted
Amendment_0004_to_SP330017B0014.pdf PDF
Updated_Attachment_7_Drawings.pdf PDF
Updated_Attachment_6_Specifications.pdf PDF
Amendment_0003.pdf PDF
Lead_Report_Building_255.pdf PDF
Amendment_0002.pdf PDF
Lead_Report_Warehouse_16.pdf PDF
Lead_Report_Building_201.pdf PDF
Lead_Report_Warehouse_19.pdf PDF
Lead_Report_Warehouse_22.pdf PDF
Lead_Report_Warehouse_14.pdf PDF
Lead_Report_Building_247.pdf PDF
Lead_Report_Warehouse_21.pdf PDF
Lead_Report_Warehouse_28.pdf PDF
Updated_SF1449_Solicitation_SP330017B0014.pdf PDF
Lead_Report_Building_231.pdf PDF
Lead_Report_Warehouse_15.pdf PDF
Lead_Report_Warehouse_20.pdf PDF
Updated_Attachment_6_-_Specifications.pdf PDF
Site_Visit_Attendee_List.pdf PDF
Updated_Attachment_6_-_Specifications.pdf PDF
Updated_SF1449_Solicitation_SP330017B0014.pdf PDF
Amendment_0001.pdf PDF
Attachment_1_-__SF24_-_Bid_Bond.pdf PDF
Attachment_3_-__SF25A_(Payment_Bond).pdf PDF
Attachment_4_Construction_Wage_Determination.pdf PDF
Attachment_6_Specifications.pdf PDF
Attachment_5_Environmental_Checklist.pdf PDF
SF1442_Solicitation.pdf PDF
Attachment_8_Submittal_Register_.pdf PDF
Attachment_7_Drawings.pdf PDF
Attachment_2_-__SF25_(Performance_Bond).pdf PDF
synopsis.pdf PDF
Show all 33

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

XRF Lead Report_WH-13_ p.1

Defense Logistics Agency - San Joaquin Tracy, California

XRF Lead Evaluation

Date: 05 July 2017 Subject: Field Analysis for Suspect Lead Paint Bulk Sample Collected from the DLASJ Tracy, Warehouse 13

Evaluation

On 05 July 2017, field testing for the presence of Lead was performed on the primary structural coatings (paints) identified on the surfaces of the building materials at the DLASJ, Tracy, Warehouse 13. Robert Miller, Certified Industrial Hygienist, and Lonny Jones, Industrial Hygiene Technician, performed the field sample analysis utilizing a handheld Innov-X Systems, Alpha Series, X-Ray Fluorescence (XRF) Spectrometer. Prior to this sampling event the calibration of the XRF instrument was verified by performing an analysis of a National Institute of Standards & Technology (NIST), Reference Material. The field testing data for Warehouse 13 is provided in Table 1 of this report.

Table 1 Sample Number

Coating / Paint Description Lead Concentration

0705-13-01 Bubble Interior: White on concrete walls Non-Detect (ND) 0705-13-02 Bubble Interior: Blue on concrete walls ND 0705-13-03 Bubble Interior: Restroom, white on drywalls ND 0705-13-04 Bubble Interior: Breakroom, White on concrete walls ND 0705-13-05 Bubble Interior: Red on wall behind fire extinguisher ND 0705-13-06 Bubble Interior: Supervisor’s Office, White on drywalls ND 0705-13-07 Bubble Interior: Branch Office, Blue on door frames ND 0705-13-08 Bubble Interior: Branch Office, White on drywalls ND 0705-13-09 Warehouse Interior: Blue on metal pedestrian doors ND 0705-13-10 Warehouse Interior: White on concrete walls ND 0705-13-11 Warehouse Interior: White on steel I-beams >5.0 mg/cm2 0705-13-12 Warehouse Interior: Blue on concrete walls ND 0705-13-13 Warehouse Interior: Yellow on steel barriers for former fire doors >5.0 mg/cm2

0705-13-14 Warehouse Interior: Yellow on metal trims on frames of former fire walls

>5.0 mg/cm2

0705-13-15 Warehouse Interior: Safety yellow on concrete floor near former fire doors

ND

0705-13-16 Warehouse Interior: Yellow on concrete bollards ND 0705-13-17 Warehouse Interior: Yellow on floor around former fire door columns

>5.0 mg/cm2

XRF Lead Report_WH-13_ p.2

0705-13-18 Warehouse Interior: Black coating on floor, yellow layer beneath, throughout warehouse

(Some readings positive, some non-detect)

>1.0 mg/cm2

ND

0705-13-19 Warehouse Interior: Yellow on floor around conveyor >5.0 mg/cm2 0705-13-20 Warehouse Exterior: Yellow paint on wood bumpers on the exterior docks >5.0 mg/cm2

0705-13-21 Warehouse Exterior: Yellow paint on the exterior metal stair rails

>5.0 mg/cm2

0705-13-22 Warehouse Exterior: Light blue paint on the exterior concrete walls

ND

0705-13-23 Warehouse Exterior: Light blue paint on the exterior side of the pedestrian doors

ND

0705-13-24 Warehouse Exterior: Blue paint on the exterior cylindrical cast iron downspouts

3.52 mg/cm2

0705-13-25 Warehouse Exterior: Blue paint on the steel beams at 450 angles located on the top of the exterior docks

>5.0 mg/cm2

0705-13-26 Warehouse Exterior: Gray paint on the I-beams located beneath the exterior docks

>5.0 mg/cm2

0705-13-27 Warehouse Exterior: Blue paint on the square downspouts and gutters

2.34 mg/cm2

0705-13-28 Warehouse Exterior: Blue paint on the blue trim on the front of the metal canopies

ND

0705-13-29 Warehouse Exterior: Blue paint on the window frames 1.80 mg/cm2

Discussion

The field testing of the coatings associated with the DLASJ Tracy, Warehouse 13, did identify Lead concentrations that are described in Table 1 of this report. The Federal OSHA 29 CFR

1926.62 and 29 CFR 1910.1025 Standards and California OSHA 8CCR 1532.1, and Title 17 CCR Standards regulate exposures to materials with any detectable amount of Lead.

Recommendations

• Any activity that may include the disturbance of Lead-containing materials must be performed within the regulations set forth in Federal OSHA 29 CFR 1926.62, 29 CFR

1910.1025 and California OSHA 8CCR 1532.1, and Title 17 CCR Standards.

• Disposal of any building materials that are coated with Lead-containing paint must be disposed of per the requirements of the DS-FJ Installation Support Environmental Office.

Robert Miller, CIH Certified Industrial Hygienist

Lonny Jones

Industrial Hygiene Technician